Electronics Finder Manufacturers S SENSATA AIRPAX JTEP-4-1REC4-52-3-B2-800
About product Specifications Datasheet FAQ

SENSATA AIRPAX JTEP-4-1REC4-52-3-B2-800

Image of SENSATA AIRPAX JTEP-4-1REC4-52-3-B2-800

Description

Circuit Breaker Magnetic Circuit Protectors 4Pole 800A 160VDC
JTEP-4-1REC4-52-3-B2-800

Part Number

JTEP-4-1REC4-52-3-B2-800

Price

Request Quote

Manufacturer

SENSATA AIRPAX

Lead Time

Request Quote

Category

Circuit Protection »  Circuit Breaker

Specifications

Manufacturer

Sensata Airpax

Manufacturers Part #

JTEP-4-1REC4-52-3-B2-800

Sub-Category

Circuit Breakers

Brand

Sensata Power Controls

Factory Pack Quantity

1

Datasheet

pdf file

jae.pdf

482 KiB

Extracted Text

JAE Series Magnetic Circuit Protectors Introduction • 205 Poles • 207 Configurations • 211 Operating Characteristics • 213 Delay Curves • 216 Decision Tables • 217 JAE/JRE/JLE Series Hydraulic Magnetic Circuit Protectors INTRODUCTION In today’s applications, ambient operating temperatures present this family is the JLE, an F-frame “listed circuit breaker” which circuit protection challenges for many design engineers. High complies with conditions of UL-489. Other members of the current thermal protective devices may not provide the desired family include the JTE, for telecommunication applications degree of protection. The JAE/JRE/JLE series magnetic- and complies to UL-489A, and the JAE, a special construction hydraulic circuit protector addresses this issue by providing version. In addition, the JAE is now in compliance with the circuit protection for high current applications with a consistent standards used in Australia and New Zealand, AS 60947.2-2005 trip point over temperatures ranging from –40°C to +85°C. (equivalent to IEC 60947-2:2006+A1). The JAE/JRE/JLE series is actually a family of circuit protectors The JAE/JRE/JLE series magnetic-hydraulic circuit protector available in one to six pole assemblies with a variety of provides circuit protection for high current applications. It configurations and terminal styles. The principle member of provides a consistent trip point over temperatures ranging from –40°C to +85°C. JAE Series - Introduction 205 http://airpax.sensata.com 1.500 2.969 ( ) 38.10 ( ) 75.41 7.125 (180.97) General Description Interrupting Capacity - - mid-trip handle available for visual identification of 10,000 amps, 160Vdc fault-tripped circuit breakers - 10,000 amps, 125/250Vdc - optional internal low voltage shunt to meter - 100,000 amps, 65Vdc (1 amps to 800 amps) current (single and multi-pole units are - 1 0,000 amps, 160Vdc (ratings ≤1000 amps) dimensionally equivalent in depth) - 65,000 amps, 65Vdc (801 amps to 1200 amps) - terminal options for design flexibility in various applications Approvals - multiple trip time delays for application flexibility - UL 489 Listed - electrical and mechanical actuated auxiliary switch - UL 489A Listed options for external monitoring of circuits - CSA Certified - reduced voltage drop through the circuit breaker - CUL/CUR Certified vs. other circuit protective devices - TUV Certified - CCC Certified Number of Poles - - 1, 2, 3, 4, 5, 6 AS 60947.2-2005 (equivalent to IEC 60947-2:2006+A1) Single-pole ratings: UL489, 250 amps max at 160 Vdc, 10,000 Current and Voltage Ratings amp interrupting capacity and 250 amps max at 65 Vdc, 65,000 - 100 to 250 amps, 160Vdc amp interrupting capacity. Multi-pole ratings: UL 489A, 800 - 100 to 250 amps, 125/250Vdc amps max at 160 Vdc, 10,000 amp interrupting capacity and 1,200 amps max at 65 Vdc, 65,000 amp interrupting capacity. - 100 to 250 amps, 65Vdc - 275 to 800 amps, 160Vdc (paralleled poles) ISO-9001 Certified - 275 to 1200 amps, 65Vdc (paralleled poles) JAE Series - Introduction 206 JAE (F-frame) Optional 1.264 3.188 .470 (32.11) (80.98) (11.94) Metering Shunt 1.266 2.406 Optional (61.11) Metering Shunt .329 ON (8.36) OPTIONAL 2.741 7.125 TRIPPED POSITION (69.62) (180.97) .470 (11.94) OFF 1.937 3.093 (49.21) (78.56) .300 .470 (7.62) (11.94) Dimension “A” .437 HOLE SHOWN 1.420 (36.07) .283 (7.18) .250 (6.36) 1.215 (30.86) R.105 TYP. 6.559 (166.61) 2X 10-32 MOUNTING SCREW ON DEPTH: .230 MIN. .315 MAX. OPTIONAL M5 2.313 (58.75) OFF .250 .300 (6.36) (7.63) 1.000 (25.40) JAE Series - Poles 207 http://airpax.sensata.com DIM.“A” Terminal Configuration BOX TERMINAL SHOWN 1.420 SEE SINGLE POLE [36.07] CONFIGURATIONS FOR ADDITIONAL Captive Nut (-F1) TERMINAL STYLES REMOVABLE LUG COVER .426 518-031-6030 .283 (LINE SIDE [7.18] ONLY) .250 [6.36] 1.215 1.170 [30.86] R.105 TYP. (29.72) 6.559 [166.61] 2X 10-32 MOUNTING SCREW. ON 1ON1 DEPTH:.230 MIN. .315 MAX. Stud (-B3) OPTIONAL M5 2.313 [58.75] OFF SCREW 3/8 - 16 UNC 2A .250 [6.36] .300 [7.63] .111 (2.82) Long Stud (-B4) 1.014 COPPER ALLOY (25.76) STANDOFF 1.500 (38.10) 2.500 (63.50) MULTI-POLE DIMENSIONS Number of Poles Dimension “A” SCREW 3/8 - 16 UNC 2A 1 1.500 [38.10] Max 2 3.000 [76.20] Max 3 4.500 [114.30] Max 4 6.000 [152.40] Max Solderless Connector (-F0) 5 7.500 [190.50] Max .734 (18.64) 6 9.000 [228.60] Max .219 (5.56) #6-300 MCM AL/CU Solderless Connector 1.670 (42.43) 1.170 (29.72) JAE Series - Poles 208 JAE (F-frame) PARALLEL MULTI-POLE ASSEMBLIES Amp Range Number of Poles Dimension “A” Dimension “B” 275 to 400 2 2.375 [60.33] Max 3.000 [76.20] Max 450 to 600 3 3.875 [98.43] Max 4.500 [114.30] Max 650 to 800 4 5.375 [136.53] Max 6.000 [152.40] Max 850 to 1000 5 6.875 [174.63] Max 7.500 [190.50] Max 1050 to 1200 6 8.375 [212.73] Max 9.000 [228.60] Max Note: Tolerance of ± 0.030 [0.762] “B” DIM.“A” 1.170 (SEE TABLE) 1.500 [29.72] [38.10] TERMINAL TYPE -B1, F1 OR -B2 .875 [22.22] 10.370 [263.40] 8.870 [225.30] JAE Series - Poles 209 http://airpax.sensata.com DIM. “C” .757 [19.23] PANEL MOUNTING DETAILS Number of Poles Dimension “C” 1 1.515 [38.48] Max 2.328 2.814 2 3.015 [76.58] Max [59.13] [71.48] 3 4.515 [114.68] Max 4 6.015 [152.78] Max 5 7.515 [190.88] Max 6 9.015 [228.98] Max .250 1.500 10-32 [6.36] [38.10] MOUNTING SCREW Notes: 1. All mounting inserts shall be utilized when panel mounting circuit breakers. Panel mounting screws shall have recommended torque applied. 2. Panel mounting screws shall not extend beyond back of mounting panel more than specified mounting insert depth. 1.607 [40.82] “B” DIM “A” 1.500 [38.10] .854 [21.69] .875 [22.22] 10.370 [263.40] ON IONI OFF BOX TERMINAL SHOWN JAE Series - Poles 210 JAE (F-frame) CONFIGURATIONS Series Trip Auxiliary Switch 1.437 (36.50) The most popular configuration This is furnished as an integral part of for magnetic protectors is the a series pole in single or multi-pole series trip, where the sensing assemblies. Isolated electrically from 1.305 coil and contacts are in series the protector’s circuit, the switch works (33.15) with the load being protected. in unison with the power contacts and The handle position conveniently provides indication at a remote location indicates circuit status. In of the protector’s on-off status. addition to providing SWITCH ONLY conventional overcurrent protection, it’s simultaneously Alarm Switch used as an on-off switch. ALARM SWITCH SERIES RLS4 Series with Auxiliary Switch Configurations PLUG SEE SWITCH OPTIONS Auxiliary Switch .416 [10.57] .235 [5.97] PLUG AUXILIARY SWITCH REC4 2.772 [70.41] Alarm & Auxiliary Switch Combination .752 C [19.11] NO NC BREAKER IN OFF POSITION .250 [6.35] 2.438 MAX. .110 [64.52] [2.79] .252 .252 ALARM AUXILIARY [6.40] [6.40] SWITCH SWITCH REC4 -IREC4 RLS4 JAE Series - Configurations 211 http://airpax.sensata.com Shunt Trip Relay Trip This permits the overload sensing coil to be placed in a circuit which is electrically isolated 1.187 from the trip contacts. The coil may be actuated [30.15] by sensors monitoring pressure, flow, 4.754 [120.76] temperature, speed, etc. Other typical applications include crowbar, interlock and emergency rapid shut down circuitry. Trip may be accomplished by voltage or current, which must be removed after trip. FLATWASHER Shunt Trip LOCKWASHER The shunt trip is designed for controlling two separate loads with one assembly. The control is established by providing overload protection 1/4-28 for the critical load. When the current through this load becomes excessive and reaches the trip point, the protector will open and remove 2 NUTS power from both loads simultaneously. The total current rating of both loads must not exceed the maximum contact rating. Relay Trip Metering Shunt 1.266 3.310 2.406 [84.06] [61.11] 1.187 [30.15] 2.741 [69.62] 1.445 [36.70] 1/4-28 ELECTRICAL 2X CONNECTORS TO METERING SHUNT AND / OR AUXI- LIARY SWITCH(ES) WHEN USED. CON- SULT FACTORY FOR CONFIGURA TIONS. METERING SHUNT/AUXILIARY SWITCH CONNECTORS Description MOLEX AMP Pin (Male) 02-09-2103 770147-1 Socket (Female) 02-09-1104 770146-1 JAE Series - Configurations 212 JAE (F-frame) OPERATING CHARACTERISTICS Trip Free Overload Will trip open on overload, even when forcibly held on. This DC rated circuit breakers will withstand 50 operations at prevents the operator from damaging the circuit by holding 600% of rated current. The current shall have no less than a the handle in the ON position. 3mSec time constant at rated voltage. Units to be operated in groups of five at the rate of operations per minute with Insulation Resistance fifteen minutes between groups to allow for cool down. Will not be less than 100 megohms at 500 volts D.C. Dielectric Strength Endurance Circuit Breaker will withstand 1000 volts plus twice rated voltage 60 Hz AC for 60 seconds from terminal to terminal. Test to be performed at rated current and rated voltage at 3mSec time constant DC. Rate of operation to be 5 Voltage Ratings operations per minute for breakers rated at 250 amps and less and 4 per minute for breakers rated above 250 amps. On all types, voltages up to and including 160 volts DC. Breakers rated above 250 amps but 600 amps or less shall Multi-pole units can be supplied for 125/250 volts Vdc. All be rated for 1000 loaded operations and 5000 mechanical units will be marked with the standard maximum voltage. operations. UL listed breakers will be labeled with the UL listed voltage. Auxiliary Switch DC Applications (typ) A choice of delays is offered for DC applications. Delay 51 When supplied will be S.P.D.T. configuration with a is a short delay for general purpose applications. Delay 52 maximum rating of 10 amperes 250 VAC 1 amp 80 Vdc. is long enough to start certain types of motors and most When optional metering shunt or parallel pole configuration transformer and capacitor loads. Delay 53 is a long delay is specified, maximum rating is 1 amp 80 Vdc. for special motor applications. All trip curves and trip currents are specified with the High-Low Temperature breaker mounted in the normal vertical position at ambient Circuit breakers will operate in the range from -40°C to temperature of +25°C. For test and measurement purposes, +85°C. All agency testing is conducted with wire sized per the breakers should not carry current prior to application 75°C chart of the National Electrical Code. In all cases the of overload for calibration test. For other than vertical breaker connections should be sized to limit the maximum mount position, consult factory. terminal temperature to 100°C absolute when the breaker is operating in the maximum ambient temperature at the maximum load current. General notes for Agency Approvals All supplementary protectors are of the overcurrent (OC) type The family of protectors has been evaluated for end use application for use group (UG) A The terminals (FW) – Terminals are coded as follows: 0 – Suitable for factory wiring only 1 – Line terminals evaluated for field wiring 2 – Load terminals evaluated for field wiring 3 – Line and load terminals evaluated for field wiring The maximum voltage ratings for which the protectors have been tested are shown in the chart The current is the amperage range that the protectors have been tested The tripping current (TC) – Tripping current is coded as a percentage of the ampere rating 0 – Tripping current is less than 125% of ampere rating 1 – Tripping current is in the range of 125% to 135% of ampere rating 2 – Tripping current is more than 135% of ampere rating 3 – Tripping current is 135% and meets MCCB trip time requirements The overload rating (OL) - designates whether the protector has been tested for general use or motor starting applications. 0 – tested at 1.5 times amp rating for general use 1 – tested at 6 times AC rating or 10 times DC rating for motor starting The short circuit current rating (SC) – The short circuit rating in amperes following a letter and number designating the test conditions and any calibration following the short circuit test is defined below: C – Indicates short circuit test was conducted with series overcurrent protection U – Indicates short circuit test was conducted without series overcurrent protection 1 – Indicates a recalibration was not conducted as part of the short circuit testing 2 – Indicates a recalibration was performed as part of the short circuit testing 3 – Indicates recalibration was performed along with the dielectric and voltage withstand for “Suitable for Further Use” rating JAE Series - Operating Characteristics 213 http://airpax.sensata.com JRE/JRM/JREP/JRMP SUPPLEMENTARY PROTECTORS - AGENCY APPROVALS Volts (Volts) Rated Current (Amps) Interrupting Capacity (Amps) Voltage (V) Frequency (Hz) UG FW Phase Min. Poles TC OL UL/CSA TUV UL 508 & CSA TUV 65 DC A 0, 3 — 1 1 1 100-250 — U2, 100000 — 65 DC A 0, 3 — 2 1 1 275-400 — U2, 100000 — 65 DC A 0, 3 — 2 1 1 450 — U2, 100000 — 65 DC A 0, 3 — 3 1 1 450-600 — U2, 100000 — 65 DC A 0, 3 — 3 1 1 700 — U2, 65000 — 65 DC A 0, 3 — 3 1 1 700 — U2, 100000 — 80 DC — — — 1 — — — 15-250 — 10000/25000 160 DC A 0, 3 — 1 1 1 100-250 15-250 U2, 10000 5000/10000 160 DC A 0, 3 — 2 1 1 251-400 — U2, 10000 — 160 DC A 0, 3 — 3 1 1 401-600 — U2, 10000 — 160 DC A 0, 3 — 3 1 1 700 — U2, 10000 — 277/480 50/60 A 0, 3 3 3 1 1 150 — U2, 5000 — JTE/JTM/JTEP/JTMP COMMUNICATIONS EQUIPMENT CIRCUIT BREAKERS - AGENCY APPROVALS Volts (Volts) Rated Current (Amps) Interrupting Capacity (Amps) Voltage (V) Frequency (Hz) Phase Min. Poles UL/CSA TUV UL 489A TUV 65 DC — 1 100 to 250 — 100000 — 65 DC — 2 275 to 400 — 100000 — 65 DC — 2 401 to 450 — 100000 — 65 DC — 3 450 to 600 — 100000 — 65 DC — 4 700 to 800 — 100000 — 65 DC — 5 900 to 1000 — 65000 — 65 DC — 6 1100 to 1200 — 65000 — 80 DC — 1 — 15 to 250 — 25000 160 DC — 1 100 to 250 15 to 250 10000 10000 160 DC — 2 251 to 400 — 10000 — 160 DC — 3 401 to 600 — 10000 — 160 DC — 4 700 to 800 — 10000 — JLE/JLM - AGENCY APPROVALS Volts (Volts) Rated Current (Amps) Interrupting Capacity (Amps) Voltage (V) Frequency (Hz) Phase Min. Poles UL/CSA TUV UL489 & CSA TUV 65 DC — 1 .10 - 250 — 100000 — 80 DC — 1 — 15 - 250 — 25000 160 DC — 1 .10 - 250 15 - 250 10000 10000 125/250 DC — 2 100 - 250 — 10000 — 240 50/60 1 1 .10 - 250 — 10000 — 240 50/60 1 & 3 2 .10 - 250 — 18000 — JAE Series - Operating Characteristics 214 JAE (F-frame) OPERATING CHARACTERISTICS PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C Delay 100% 125% (Note A) 150% 200% 400% 600% 800% 1000% 51 & 51F No Trip .5 to 10 .25 to 3 .15 to 9 .05 to .3 .015 to .15 .01 to .09 .01 to .04 52 & 52F No Trip 9 to 90 5 to 40 2 to 15 .5 to 3 .03 to 1 .01 to .28 .01 to .08 53 & 53F No Trip 100 to 1000 50 to 400 22 to 150 4 to 25 .5 to 5 .010 to 2 .01 to .1 61 & 61F No Trip .4 to 10 .25 to 3 .13 to .9 .03 to .2 .015 to .15 .01 to .09 .008 to .045 62 & 62F No Trip 9 to 95 5 to 40 2 to 15 .05 to 3 .03 to 1 .01 to .28 .008 to .08 63 & 63F No Trip 100 to 1100 48 to 400 20 to 150 4 to 25 .5 to 6 .01 to 2 .008 to .1 NOMINAL DCR / IMPEDANCE RECOMMENDED TORQUE SPECIFICATIONS Resistance (ohms) Component Torque (in-lbs) Current Ratings DC Delays 10-32 Mounting Inserts 10 to 12 (Amps) M5 Mounting Inserts 8 to 10 51, 52, 53 3/8-16 and M10 x 1.5 Captive Nuts 220 to 230 100 .000375 3/8-16 and M10 x 1.5 Studs 220 to 230 110 .000375 Solderless Connectors 180 125 .000340 150 .000325 175 .000315 APPROXIMATE WEIGHT PER POLE 200 .000225 Pounds Grams 225 .000225 2.25 1020 250 .000225 400 .000125 600 .000083 INRUSH PULSE TOLERANCE 800 .000063 1,000 .000050 Delay Pulse Tolerance 1,200 .000042 61, 62, 63 8 times rated current (approx) Notes: 61F, 62F, 63F 12 times rated current (approx) Resistance is plus or minus 50%. If a metering shunt option is provided it will add the shunts resistance to these values (i.e. A 400 Amp metering shunt would add (R=V/I). 0000625 Ohms of Inrush Pulse Tolerance resistance to the non-metering shunt value of .000125 Ohms or .0001875 Ohms The table shown provides a comparison of inrush pulse for a 400 Amp unit with a metering shunt). tolerance with and without the inertial delay feature for each DC resistance values are based on measurements by the voltmeter ammeter of the 50/60Hz delays. Pulse tolerance is defined as a single method. Rated current applied for one hour and at a voltage not less than 20 pulse of half sine wave peak current amplitude of 8 volts. milliseconds duration that will not trip the circuit breaker. JAE Series - Operating Characteristics 215 http://airpax.sensata.com DELAY CURVES 10000 10000 10000 10000 1000 1000 1000 1000 DELAY 51 & 51F DELAY 61 & 61F DELAY 51 & 51F DELAY 61 & 61F 100 100 100 100 10 10 10 10 1 1 1 1 .1 .1 .1 .1 .01 .01 .01 .01 .001 .001 .001 .001 0100 150 200 300 400 500 600 700 800 900 1000 0100 150 200 300400 500 600 700 800 9001000 0100 150 200 300 400 500 600 700 800 900 1000 0100 150 200 300400 500 600 700 800 9001000 125 125 125 125 PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT 10000 10000 10000 10000 1000 1000 1000 1000 DELAY 62 & 62F DELAY 52 & 52F DELAY 62 & 62F DELAY 52 & 52F 100 100 100 100 10 10 10 10 1 1 1 1 .1 .1 .1 .1 .01 .01 .01 .01 .001 .001 .001 .001 0100 150 200 300 400 500 600 700 800 900 1000 0100 150 200 300 400 500 600 700 800 900 1000 0100 150 200 300 400 500 600 700 800 9001000 0100 150 200 300 400 500 600 700 800 9001000 125 125 125 125 PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT 10000 10000 10000 10000 1000 1000 1000 1000 DELAY 63 & 63F DELAY 53 & 53F DELAY 63 & 63F DELAY 53 & 53F 100 100 100 100 10 10 10 10 1 1 1 1 .1 .1 .1 .1 .01 .01 .01 .01 .001 .001 .001 .001 0100 150 200 300 400 500 600 700 800 900 1000 0100 150 200 300 400 500 600 700 800 900 1000 0100 150 200 300 400 500 600 700 800 900 1000 0100 150 200 300 400 500 600 700 800 900 1000 125 125 125 125 PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT JAE Series - Delay Curves 216 TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS MAY TRIP MAY TRIP MAY TRIP MAY TRIP MAY TRIP MAY TRIP TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS MAY TRIP MAY TRIP MAY TRIP MAY TRIP MAY TRIP MAY TRIP JAE (F-frame) 2 4 1 Second Decision Fourth Decision First Decision Type Poles Frequency and Delay How to Order -1* Single pole Standard Option JLE UL Listed 6 Sixth Decision The ordering code for JAE/JRE/JLE F-Frame Circuit Protectors 50 DC instant trip -2 Two poles JLM UL Listed Mid Trip Construction may be determined by following the steps in the decision tables Terminal Selection 51 DC short delay 51F shown here. -3 Three poles JRE UL Recognized Terminal Terminal Connect 52 DC med. delay 52F -4 Four poles JREP UL Recognized above 250 amps The coding given permits a self-assigning part number for -B0 Solderless connector* Back -5 Five poles 53 DC long delay 53F JRM UL Recognized Mid Trip standard configurations. Factory part numbers are assigned to Construction -F0 Solderless connector Front units with mixed ratings, combinations of styles or construction -6 Six poles 60 50/60Hz instant trip not listed in the Third Decision Table, etc. With these, it is JRMP UL Recognized Mid Trip -B1 3/8 - 16 captive nuts Back 61 50/60Hz short delay 61F *Single pole unit above 250 Amps are supplied as Construction above 250 amps suggested that order entry be by description and/or drawings, parallel milti-pole assemblies. The second decision must -F1 3/8 - 16 captive nuts Front indicate the physical number of poles. 62 50/60Hz med. delay 62F and a part number will be established. JTE UL Listed Telecom Specication -B2 .437 hole – 63 50/60Hz long delay 63F JTEP UL Listed Telecom Specication Additionally, it is standard policy to establish a factory-assigned above 250 amps -B3 3/8 - 16 stud terminals** Back SW Switch only part number whenever a descriptive drawing exists to ensure JTM UL Listed Telecom Specication -F3 3/8 - 16 stud terminals Front cross reference, traceability and manufacturing control. An F after any delay denotes high pulse Mid Trip Construction tolerance construction. -B4 3/8 - 16 stud terminals Back JTMP UL Listed Telecom Specication For example, the following is the code for a single pole breaker long with spacers* Mid Trip Construction above series trip, with mid-trip handle indication, auxiliary switch, short 250 amps * Automatically get anti-ashover for multi-pole construction. Refer to outline drawings. delay, 65 volts DC maximum voltage rating with 3/8-16 captive nuts JAE Non Agency in a current rating of 250 amperes and metric inserts. Example: ** Automatically get anti-ashover barrier for JLM -1 - IREC4 - 51- 1 - F1 - 250 - A - V multi-pole construction with voltage ratings JAEP Non Agency above 250 amps above 250 volts. To determine the ordering number of your particular JAE/JRE/ JAM Non Agency Mid Trip 1 2 3 4 5 6 7 8 JLE unit, simply follow the steps shown. You may use this Construction number to place an order or as a reference for further questions JAMP Non Agency Mid Trip you may have. Construction above 250 amps 3 Third Decision 7 Seventh Decision Internal Conguration Current Ratings (see note J) -0 Switch only 5 Fifth Decision Amperes Amperes Voltage and Current -1 Series 100 450 Maximum Maximum -3 Shunt construction*** 125 500 Voltage Current (Amps) Notes: E The coding given permits a self-assigning part number but with certain -4 Relay construction*** 150 550 -1 65Vdc 1200A limitations, (due to the adaptability of magnetic protectors to complex circuits) A 10-32 inserts are provided for front mounting on all units. M5 ISO metric mounting -REC4 Auxiliary switch* (STD) 175 600 which require a need for a factory assigned part number. Typical examples -2 125Vdc 800A inserts are available and are specified by the eight decision in the part number. .110 quick connect are units with mixed ratings, combinations of styles, or construction not listed -3 160Vdc 800A 200 700 in the third decision table, etc. With these, it is suggested that order entry -REG4 Auxiliary switch* B The auxiliary switch is located on the left hand pole (viewed from terminal end) -4 125/250Vdc* 250A be by description and/or drawings, and a part number will be established. .110 quick connect** 225 800 unless specified otherwise. Note this is the only location available for breakers -5 240Vac 250A Additionally, it is standard policy to establish a factory assigned part number rated over 250 amps. The switch is available as an alarm switch (changes -REC5 Auxiliary switch* 250 900 wherever a descriptive drawing exists to provide cross-reference, traceability, -6 277Vac 250A (STD) .187 quick connect state when breaker electrically trips) or as an auxiliary switch (changes state and manufacturing control. 275 1000 -7 277/480Vac 150A Only when the breaker contacts change state either from tripping or operation of -RLS4 Alarm switch* the breaker handle). See outline drawing for location of alarm and auxiliary (STD) .110 quick connect *Two poles breaking 300 1100 F When specifying a protector for AC motor start or high inrush applications, the switches. Note alarm switches are available only with mid trip option. When peak amplitude and surge duration should be specified for factory assistance -RLS5 Alarm switch* both an alarm and auxiliary switch are specified with a metering shunt, only 350 1200 in rating selection. .187 quick connect V = TUV and CCC Approved the C and NO or C and NC terminals from each switch are available for field 400 termination. -DAA4 Dual auxiliary & alarm switch* G Since magnetic protectors with time delay are somewhat attitude and Approval requires the addition of a V at (STD) .110 quick connect the end of the part number, which denotes temperature sensitive, all trip curves and trip currents are specified with the C 3/8-16 captive nuts are available for bus bar terminations or crimp lugs TUV and CCC approval. Consult the factory protector mounted in the normal vertical position at ambient temperature -DAA5 Dual auxiliary & alarm switch* for availability. (specify front or back termination). 3/8-16 long and short studs are also of 25°C. Protectors do not carry current prior to application of overload for .187 quick connect available (specify front or back mount). A number 6 through 300 MCM AL/CU calibration test. For other than vertical mount position, consult factory. solderless connector is available (specify front or back mount). * Auxiliary switch located in the left hand pole when C = CCC Approved viewed from the terminal end. All meter shunt and 8 H A 25mV at rated current non-isolated metering shunt is available as an option Eighth Decision parallel pole builds that require an auxiliary switch will D Only series construction and DC ratings are available in current carrying poles (see outline drawing). The shunt accuracy is 1% full scale 25°C ambient. automatically get a XXX4 type switch. To connect to This approval requires the addition of a C Optional above 250 amps. Consult factory for special requirements. the switch terminals which are brought through the at the end of the part number. The unit cover use a Molex 02-09-1104 or an Amp 770146-1 I Dual coil construction is available. Consult the factory. will not be TUV Approved. crimp terminal. A Optional metric inserts M5 ** Gold Contacts S Optional metering shunt J Decisions referencing this note may be replaced by a factory assigned *** Shunt and Relay construction not available above nondescript number. 250 Amps and not available in UL Listed Breakers JAE Series - Decision Tables 217 http://airpax.sensata.com 2 4 1 Second Decision Fourth Decision First Decision Type Poles Frequency and Delay -1* Single pole Standard Option JLE UL Listed 6 Sixth Decision 50 DC instant trip -2 Two poles JLM UL Listed Mid Trip Construction Terminal Selection 51 DC short delay 51F -3 Three poles JRE UL Recognized Terminal Terminal Connect 52 DC med. delay 52F -4 Four poles JREP UL Recognized above 250 amps -B0 Solderless connector* Back -5 Five poles 53 DC long delay 53F JRM UL Recognized Mid Trip Construction -F0 Solderless connector Front -6 Six poles 60 50/60Hz instant trip JRMP UL Recognized Mid Trip -B1 3/8 - 16 captive nuts Back 61 50/60Hz short delay 61F *Single pole unit above 250 Amps are supplied as Construction above 250 amps parallel milti-pole assemblies. The second decision must -F1 3/8 - 16 captive nuts Front indicate the physical number of poles. 62 50/60Hz med. delay 62F JTE UL Listed Telecom Specication -B2 .437 hole – 63 50/60Hz long delay 63F JTEP UL Listed Telecom Specication above 250 amps -B3 3/8 - 16 stud terminals** Back SW Switch only JTM UL Listed Telecom Specication -F3 3/8 - 16 stud terminals Front An F after any delay denotes high pulse Mid Trip Construction tolerance construction. -B4 3/8 - 16 stud terminals Back JTMP UL Listed Telecom Specication long with spacers* Mid Trip Construction above 250 amps * Automatically get anti-ashover for multi-pole construction. Refer to outline drawings. JAE Non Agency Example: ** Automatically get anti-ashover barrier for JLM -1 - IREC4 - 51- 1 - F1 - 250 - A - V multi-pole construction with voltage ratings JAEP Non Agency above 250 amps above 250 volts. JAM Non Agency Mid Trip 1 2 3 4 5 6 7 8 Construction JAMP Non Agency Mid Trip Construction above 250 amps 3 Third Decision 7 Seventh Decision Internal Conguration Current Ratings (see note J) -0 Switch only 5 Fifth Decision Amperes Amperes Voltage and Current -1 Series 100 450 Maximum Maximum -3 Shunt construction*** 125 500 Voltage Current (Amps) -4 Relay construction*** 150 550 -1 65Vdc 1200A -REC4 Auxiliary switch* (STD) 175 600 -2 125Vdc 800A .110 quick connect -3 160Vdc 800A 200 700 -REG4 Auxiliary switch* -4 125/250Vdc* 250A .110 quick connect** 225 800 -5 240Vac 250A -REC5 Auxiliary switch* 250 900 -6 277Vac 250A (STD) .187 quick connect 275 1000 -7 277/480Vac 150A Only -RLS4 Alarm switch* (STD) .110 quick connect *Two poles breaking 300 1100 -RLS5 Alarm switch* 350 1200 .187 quick connect V = TUV and CCC Approved 400 -DAA4 Dual auxiliary & alarm switch* Approval requires the addition of a V at (STD) .110 quick connect the end of the part number, which denotes TUV and CCC approval. Consult the factory -DAA5 Dual auxiliary & alarm switch* for availability. .187 quick connect * Auxiliary switch located in the left hand pole when C = CCC Approved viewed from the terminal end. All meter shunt and 8 Eighth Decision parallel pole builds that require an auxiliary switch will automatically get a XXX4 type switch. To connect to This approval requires the addition of a C Optional the switch terminals which are brought through the at the end of the part number. The unit cover use a Molex 02-09-1104 or an Amp 770146-1 will not be TUV Approved. crimp terminal. A Optional metric inserts M5 ** Gold Contacts S Optional metering shunt *** Shunt and Relay construction not available above 250 Amps and not available in UL Listed Breakers 209 (E-frame)

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the JTEP-4-1REC4-52-3-B2-800?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Sensata Technologies 203-2-1-52-103-5-3-18

product

Circuit Breaker Supplementary Protector 1Pole 5A 250VAC 203-2-1-63-502-4-1-1

product

Circuit Breaker Supplementary Protector 1Pole 2.5A 250VAC 203-2-1-66F-252-G-1-16

product

Circuit Breaker Supplementary Protector 2Pole 10A 250VAC 203-22-1-60-103-C-1-32

product

Sensata Technologies 203-22-1-61-502-E-1-1-A

product

Circuit Breaker Supplementary Protector 2Pole 10A 250VAC 203-22-1-62F-103-4-3-13