SENSATA AIRPAX PP11-2-2.00A-OC-V
Specifications
Manufacturer
Sensata Airpax
Manufacturers Part #
PP11-2-2.00A-OC-V
Industry Aliases
PP11-2-2.00A-OC-V
Sub-Category
Circuit Breakers
Brand
Sensata Power Controls
Factory Pack Quantity
1
Datasheet
Extracted Text
Snapak® Series Magnetic Circuit Protectors Introduction • 55 Handles • 56 Configurations • 61 Operating Characteristics • 63 Delay Curves • 64 Specifications • 65 Hardware • 66 Decision Tables • 67 T/R/PP/PR/CR/CPP/CPR Series Hydraulic Magnetic Circuit Protectors (SNAPAK®) INTRODUCTION The Airpax™ SNAPAK® series is a snap-acting hydraulic- Since the SNAPAK® is snap-acting, it assures immediate magnetic circuit protector that combines power switching and opening and closing of the contacts. Its design also prevents accurate, reliable circuit protection in one aesthetically pleasing operator “teasing” of the contacts and minimizes arcing. package. The SNAPAK® combines the functions of three SNAPAK® circuit protectors are UL Recognized as separate components: power switch, fuse and fuse holder. To the supplementary protectors per UL STD. 1077, CSA Certified as OEM, this means that only one item has to be mounted instead supplementary protectors per CSA STD. C22.2 No. 235, TUV of three. Less assembly is required, inventory is cut by two- Approved as circuit breakers for equipment per STD. EN 60934, thirds and greater panel density is obtainable with less clutter. In CCC Approved (customer must request product be manufactured addition, the SNAPAK® can be operated at either DC or 50/60Hz, in China) and CE Compliant. In addition, most versions are eliminating the need to specify, order and stock separate units. certified by UL to meet spacing requirements of IEC 950 for basic 400Hz units are also available. and functional insulation for front panel mounting. To enhance front-panel aesthetics, SNAPAK® is offered with Consult factory for details and exceptions. Typical applications paddle and rocker handles in six attractive colors and push-pull include office appliances, electronic data processing, medical and push-to-reset actuators. Also offered is a variety of optional equipment, business machines, vending and amusement mounting hardware. The push-pull version is supplied with a machines. Push-pull versions are particularly well suited for black button with a white indicating band. medical instrumentation, automotive production transfer lines and other applications where accidental turn off is unacceptable. Orientation of the button when marked with an amperage For those applications which do not require circuit protection, notation must be specified when using the fourth decision table. SNAPAK® is offered in a power-switch-only configuration. Push-to-reset is supplied with a contrasting color indicating shaft. In addition, SNAPAK® is offered in SPST and DPST configurations. The single pole satisfies most applications. The two-pole version is often used for extra safety in products that utilize high voltage or where current sensing and breaking of both sides of the line is required. Quick connect terminals are standard, UNC 8-32 or M4 screw terminals are available as additional termination options. 55 SNAPAK® Series - Introduction http://airpax.sensata.com Mounting Details with Locking Ring .010 .500 ± .000 .355 .025 [12.70 ± ] [9.02] .000 .125 [3.18] TOGGLE ACTUATORS without Locking Ring The SNAPAK® is available with paddle handles .010 .500 ± in six attractive colors. Engineered for safe, sure .000 .222 ± 0.002 operation, the paddle handles may be specified in .025 [12.70 ± ] blue, white, red, green, yellow or black. [5.64 ± 0.05] .000 PANEL CUTOUT SHOWN ABOVE MAY BE MADE WITH GREENLEE RADIO CHASSIS PUNCH #733 x 1/2” DIA. Note: Mounting Tolerance ± .005 [.13] unless noted angles: ±5°. Dimensions in Brackets [ ] are millimeters. Single Pole, Toggle .680 ± 0.010 .125 ± 0.010 1/2 - 32 THD [17.27 ± 0.25] [3.17 ± 0.25] 2 15º ON 1.125 ± 0.030 1.375 ± 0.010 Paddle Handle .031 [28.58 ± 0.76] [34.93 ± 0.25] [0.79] OFF 1 LINE FLAT 15º 0.500 ± 0.030 .375 ± 0.010 .250 [12.70 ± 0.76] [9.53 ± 0.25] [6.35] 1.715 ± 0.030 [43.56 ± 0.76] .468 ± 0.010 [11.89 ± 0.25] Two Pole, Toggle 1.304 ± 0.010 .625 ± 0.010 .125 ± 0.010 [33.12 ± 0.25] 1/2 - 32 THD [15.88 ± 0.25] [3.17 ± 0.25] POLE 1 POLE 2 2 4 15º ON 1.125 ± 0.030 1.375 ± 0.010 Paddle Handle .031 [28.58 ± 0.76] [34.93 ± 0.25] OFF [0.79] LINE 3 1 LINE FLAT 15º 0.500 ± 0.030 .375 ± 0.010 .250 [12.70 ± 0.76] [9.53 ± 0.25] [6.35] 1.715 ± 0.030 [43.56 ± 0.76] .468 ± 0.010 [11.89 ± 0.25] SNAPAK® Series - Handles 56 SNAPAK® (T/R/PP/PR CR/CPP/CPR) Mounting Detail ROCKER HANDLES WITH ILLUMINATION .010 .710 ± .000 SNAPAKs are offered in single and two pole rocker styles in a choice .025 [18.03 ± ] of black, white or gray body colors. Handle color in non-illuminated .000 types may be black, red, white or orange. Neon or light emitting diode (LED) illumination may be specified with a variety of options. DIM. A (SEE TABLE) ® SNAPAK circuit protectors with a second pole are available in paddle handle, push-pull, push-to-reset and rocker handle versions. Rocker, Single Pole 0.030 ± 0.325 0.680 ± 0.010 0.770 ± 0.010 0.125 ± 0.010 [8.26 ± 0.76] [17.27 ± 0.25] [19.56 ± 0.25] [3.18 ± 0.25] 2 1.375 ± 0.010 ON 1.125 ± 0.030 1.560 ± 0.010 0.972 ± 0.010 [34.93 ± 0.25] 0.031 [28.58 ± 0.76] [39.62 ± 0.25] [24.69 ± 0.25] OFF [0.79] 1 LINE 0.375 ± 0.010 0.250 [9.53 ± 0.25] [6.35] 1.840 ± 0.030 0.093 ± 0.010 0.400 ± 0.010 [46.74 ± 0.76] [2.36 ± 0.25] [10.16 ± 0.25] Handle Guards, Single Pole HANDLE GUARDS 0.305 ± 0.010 ® [7.75 ± 0.25] The SNAPAK circuit protector is available with an optional handle guard as an integrated part of the snap-in mounting design. Available for rocker actuators, the guard helps in 1.047 ± 0.010 providing protection from accidental “turn-off.” Please refer to ® [26.60 ± 0.25] the SNAPAK Part Number Decision Tables; fourth decision. Handle Guards, Two Pole 0.305 ± 0.010 [7.75 ± 0.25] 1.047 ± 0.010 [26.60 ± 0.25] 57 SNAPAK® Series - Handles http://airpax.sensata.com Mounting Detail FRONT SNAP-IN MOUNT (STD) .010 1.329 ± .000 Panel Thickness 0.125 0.093 0.062 .025 [33.76 ± ] .000 [3.18] [2.36] [1.57] Dimension “A” 1.460 1.420 1.385 DIM. A [37.08] [36.07] [35.18] (SEE TABLE) Note: Tolerance for Mtg. ± .005 (.13) Rocker, Two Pole 1.304 ± 0.010 0.030 ± 0.325 [33.12 ± 0.25] 1.394 ± 0.010 0.125 ± 0.010 [8.26 ± 0.76] [35.41 ± 0.25] [3.18 ± 0.25] POLE 1 POLE 2 2 4 1.375 ± 0.010 ON 1.125 ± 0.030 1.560 ± 0.010 0.972 ± 0.010 [34.93 ± 0.25] 0.031 [28.58 ± 0.76] [39.62 ± 0.25] [24.69 ± 0.25] OFF [0.79] 1 LINE LINE 3 0.375 ± 0.010 0.250 [9.53 ± 0.25] [6.35] 1.840 ± 0.030 0.093 ± 0.010 0.400 ± 0.010 [46.74 ± 0.76] [2.36 ± 0.25] 0.625 ± 0.010 [10.16 ± 0.25] [15.88 ± 0.25] Illuminated Handle Two Pole Single Pole LOAD LOAD 2 4 2 1 LINE LINE 3 1 LINE LINE LINE RED (+), BLACK(–) RED (+), BLACK (-) 7.00 ± 0.50 7.00 ± 0.50 [177.8 ± 12.7] [177.8 ± 12.7] Note: Tolerance ± .005 [.13] unless noted angles: ±5°. Dimensions in Brackets [ ] are millimeters. SNAPAK® Series - Handles 58 SNAPAK® (T/R/PP/PR CR/CPP/CPR) PUSH-PULL, PUSH-TO-RESET ACTUATOR ® SNAPAK may also be ordered with Push-Pull, or Push- to-Reset actuator buttons. As an option, the button can be embossed with the current rating (Push-Pull option only). Push-Pull, Single Pole Push-Pull, Two Pole 1.960 ± 0.030 .400 ± 0.010 1.960 ± 0.030 .400 ± 0.010 [49.78 ± 0.76] [10.16 ± 0.25] [49.78 ± 0.76] [10.16 ± 0.25] FLAT FLAT Push-Pull Actuation Push-Pull Actuation .375 ± 0.010 0.500 ± 0.030 OFF (SHOWN) 0.500 ± 0.030 [9.53 ± 0.25] [12.70 ± 0.76] .375 ± 0.010 3/8 - 32 THD OFF (SHOWN) [9.53 ± 0.25] 3/8 - 32 THD [12.70 ± 0.76] 0.250 ± 0.030 WHITE BAND VISIBLE 0.250 ± 0.030 ON WHITE BAND VISIBLE ON IN OFF POSITION ONLY [6.35 ± 0.76] IN OFF POSITION ONLY [6.35 ± 0.76] 1.125 ± 0.030 1.125 ± 0.030 .125 ± 0.010 [28.58 ± 0.76] .125 ± 0.010 [28.58 ± 0.76] [3.18 ± 0.25] [3.18 ± 0.25] POLE 2 .250 .625 ± 0.010 [6.35] .250 [15.88 ± 0.25] POLE 1 [6.35] .031 [.79] .031 [.79] 1.375 ± 0.010 1.375 ± 0.010 [34.93 ± 0.25] [34.93 ± 0.25] .680 ± 0.010 1.304 ± 0.010 [17.27 ± 0.25] [33.12 ± 0.25] Mounting Detail Push-to-Reset Actuation (Single Pole and Two Pole) (Single and Two Pole) .162 ± 0.002 .010 .375 ± [4.11 ± 0.05] .000 .025 0.76 ± 0.030 [9.53 ± ] .000 OFF [6.35 ± 0.25] FLUSH ± 0.030 ON [FLUSH ± 0.25] Note: Tolerance ± .005 [.13] unless noted angles: ±5°. Dimensions in Brackets [ ] are millimeters. 59 SNAPAK® Series - Handles http://airpax.sensata.com 2 1 LINE 2 4 1 LINE LINE 3 Toggle SCREW TERMINALS Available as straight screw terminals with UNC 8-32 and Metric M4 screw types, bus-type connect (flat) or upturned lugs (tabs), with UL, CSA and TÜV approvals available. Screw terminals are available for all handle options (rocker, toggle, push-pull, push-to-reset). Single pole only, DIM. “A” series only, non-auxiliary switch configurations. DIM. “A” (SEE TABLE) (SEE TABLE) Push Button DIMENSION “A” Handle Style Screw Terminal “A” Dimension Toggle Straight 1.773 [45.03] Push Button Straight 2.180 [55.37] Rocker Straight 2.058 [52.27] DIM. “A” DIM. “A” (SEE TABLE) (SEE TABLE) Rocker DIM. “A” DIM. “A” (SEE TABLE) (SEE TABLE) Straight 0.582 0.574 0.597 TABS 0.582 0.574 [14.78] 0.597 [14.58] [15.16] TABS 0.561 [14.78] [14.58] [15.16] FLAT [14.25] 0.561 FLAT [14.25] 1.067 0.374 30º 0.374 0.374 25º [27.11] 1.067 0.374 0.374 0.374 [9.50] [9.50] [9.50] 30º 25º [27.11] [9.50] [9.50] [9.50] SNAPAK® Series - Handles 60 SNAPAK® (T/R/PP/PR CR/CPP/CPR) Series Trip Two CONFIGURATIONS Single Pole Pole Series Trip LOAD LOAD The most popular configuration for magnetic protectors is the 2 4 2 series trip where the sensing coil and the contacts are in series with the load being protected. In addition to providing conventional overcurrent protection, it is simultaneously used 1 LINE 1 LINE LINE 3 as an on-off switch. LINE LINE Shunt Trip Two Pole Single Pole ( 1 pole shunt) Shunt Trip LOAD SHUNT SHUNT The shunt trip is designed for controlling two separate loads 2 4 with one assembly. The control is established by providing LOAD LOAD overload protection for the critical load. When the current through this load becomes excessive and reaches the trip LINE 1 LINE LINE 3 point, the protector will open and remove power from both LINE loads simultaneously. The current rating of both loads must WHITE LEAD WHITE LEAD not exceed the maximum contact rating. 7.00 ± 0.50 7.00 ± 0.50 [177.8 ± 12.7] [177.8 ± 12.7] Relay Trip (Note A) Two Pole Single Pole (1 pole relay) Relay Trip LOAD LOAD 2 This permits the overload sensing coil to be placed in a circuit 4 2 COIL COIL which is electrically isolated from the contacts. The coil may be actuated by sensors monitoring pressure, flow, COIL COIL temperature, speed, etc. Other typical applications include 1 LINE LINE LINE 3 1 LINE crowbar, interlock and emergency/rapid shutdown circuitry. LINE Trip may be accomplished by voltage or current, which must WHITE LEAD WHITE LEAD be removed after trip. 7.00 ± 0.50 7.00 ± 0.50 [177.8 ± 12.7] [177.8 ± 12.7] Note A: Coil Ratings to 5 amperes maximum. Contact ratings are 7.5 amperes at 50 Vdc and 250 Vac; 15 amperes at 120 Vac; 32 Vdc. Note: Tolerance ± .005 [.13] unless noted. Dimensions in Brackets [ ] are millimeters. 61 SNAPAK® Series - Configurations http://airpax.sensata.com Auxiliary Switch (Note B) Single Pole Auxiliary Switch 2 C 0.040 [1.02] DIA. HOLE 0.093 This is furnished as an integral part of a series pole in single N (FOR SOLDER ATTACHMENT) C N or, multi-pole assemblies. Isolated electrically from the [2.36] O protector s circuit, the switch works in unison with the power 1 LINE contacts and provides indication at a remote location of the protector’s ON-OFF status. .100 to 20.0 amps, VDE, TÜV >20amps NON-VDE & & U3 Construction NON-TÜV >20amps .560 ± 0.030 LOAD LOAD [14.22 ± 0.76] C NC NC NO NO C LINE LINE Voltage Trip BREAKER SHOWN BREAKER SHOWN Sometimes called “dump circuits” or “panic trip circuits,” IN OFF POSITION IN OFF POSITION these units make it possible to open main power contacts with lower power inputs from one or more sources. This configuration is becoming increasingly more important for sensitive circuitry and denser packaging in automation systems. Available in series, shunt or relay configurations. Auxiliary Switch (Note B) Two Pole 2 4 C 0.040 [1.02] DIA. HOLE 0.093 N C (FOR SOLDER ATTACHMENT) N [2.36] O 1 LINE LINE 3 Power Switch In the event that over-current protection is not desired, the coil mechanism can be deleted, providing an excellent low cost single or double-pole power switch. Maximum current rating is .100 to 20.0 amps, VDE, TÜV >20amps 20 amps. NON-VDE & & U3 Construction NON-TÜV >20amps .560 ± 0.030 LOAD LOAD [14.22 ± 0.76] C NC NC NO NO C LINE LINE BREAKER SHOWN BREAKER SHOWN IN OFF POSITION IN OFF POSITION Note B: Switch is located in the left hand pole (viewed from terminal end). SNAPAK® Series - Configurations 62 SNAPAK® (T/R/PP/PR CR/CPP/CPR) OPERATING CHARACTERISTICS MAXIMUM DCR AND IMPEDANCE Inrush Pulse Tolerance Current Ratings T/R/PP/PR T/R/PP/PR CR/CPP/CPR Many circuit protector applications involve a (Amps) DC Resistance 50/60Hz Impedance DC Resistance transformer turn-on, an incandescent lamp load, .100 175 181 274 or a capacitor charge from a DC source. Each of these applications has one common factor: a .500 6.34 6.63 9.77 steep transient of very high current amplitude and 1.00 1.63 1.69 2.31 short duration. This takes the form of a spike or a 2.00 .400 .425 .465 single pulse and is the cause of most nuisance tripping associated with magnetic circuit 3.00 .175 .188 .261 breakers. 4.00 .103 .106 .156 ® 5.00 .076 .078 .091 SNAPAK will withstand, without tripping, a single pulse of 8 milli-seconds duration (half sine wave 7.50 .038 .039 .053 configuration) and peak amplitude of 9 times its 10.0 .026 .028 .023 rating without the inertia wheel and 13 times its rating with an inertia wheel. (Not applicable to 12.5 .020 .021 .020 instant trip delays). 15.0 .013 .014 .010 20.0 .010 .011 .008 25.0 .004 30.0 .003 DCR and Impedance is measured after 1 hour at 100% rated current using the Voltmeter-Ammeter Method. PULSE TOLERANCE Delay Pulse Tolerance 1, 2, 61, 62 *9 Times Rated Current 3, 4, 61F, 62F *13 Times Rated Current * Units above 15 amps are derated to 8 and 12 times rated current PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C (VERTICAL MOUNT) Delay 100% 135% 150% * 200% 400% 600% 800% Instant No Trip May Trip .100 Max .100 Max .100 Max .100 Max .100 Max Fast No Trip .3 to 7 .2 to 5 .1 to 2 .03 to .50 .015 to .30 .010 to .150 Slow No Trip 3 to 70 2 to 40 1 to 15 .10 to 4.0 .015 to 2.0 .010 to .800 * Minimum trip for all instantaneous and 400Hz units. 63 SNAPAK® Series - Operating Characteristics http://airpax.sensata.com 10000 DELAY CURVES & SPECIFICATIONS 1000 INSTANT 400 Hz, DC, 50/60Hz Delay Curves (typ) 100 A choice of delays is offered for DC, 50/60Hz and 400Hz 10 applications. Delays 0, 49, 59 and 69 provide fast-acting, instantaneous trip and are often used to protect sensitive 1 electronic equipment (not recommended where known inrush exists). Delays 1, 41, 51 and 61 have a short delay for general .1 purpose applications. Delays 2, 42, 52 and 62 are long enough to .01 start certain types of motors and most transformer and capacitor loads. .001 0 100 150 200 300 400 500 600 700 800 900 1000 135 Trip Free PERCENT OF RATED CURRENT Will trip open on overload, even when forcibly held on.This prevents operator from damaging the circuit by holding handle in the ON position. 10000 Trip Indication 1000 The operating handle moves forcibly and positively to the OFF FAST position on overload. 100 Ambient Operation 10 Operates normally in temperatures between –40° C and +85°C. 1 Insulation Resistance .1 Not less than 100 megohms at 500Vdc. .01 Dielectric Strength .001 0 100 150 200 300 400 500 600 700 800 900 1000 Withstands 1500 volts, 60Hz for 60 seconds or 1800Vac for one 135 PERCENT OF RATED CURRENT second between all electrically isolated terminals. Endurance Mechanical life in excess of 50,000 operations. In many applications, however, contact wear due to the electrical load 10000 determines unit life. At maximum electrical ratings, the ® SNAPAK can perform 10,000 operations at rated current and 1000 SLOW ® voltage. Under UL 1077, the SNAPAK can perform 50 operations at 150% of maximum rated current followed by 6,000 100 operations at maximum rated current. Under EN60934 the ® 10 SNAPAK can perform 6,000 electrical operations. After any endurance cycle, the breaker will calibrate and have working 1 dielectric strength. .1 .01 .001 0 100 150 200 300 400 500 600 700 800 900 1000 135 PERCENT OF RATED CURRENT SNAPAK® Series - Delay Curves 64 TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS MAY TRIP MAY TRIP MAY TRIP SNAPAK® (T/R/PP/PR CR/CPP/CPR) AGENCY APPROVALS (T/P/PP/PR SUPPLEMENTARY PROTECTORS) Voltage (Volts), Frequency (hz), Phase, Min Poles, TC, OL Current (Amps) Short Circuit Current Rating (Amps) Voltage Frequency (Hz) Phase Min. Poles TC OL UL/CSA TUV UL 1077 & CSA TUV Notes 32 DC - 1 1 0 .10-30(3) .10-20 U1, 1000 500 38 DC - 1 1 0 .10-15 - U2, 1000 / U1, 1000 - PR only 65 DC - 1 1 0 .10-7.5 - U2, 500 /U1, 500 - 65 DC - 2 1 0 .10-15 - U1, 1000 - 65 DC - 2 1 0 .10-20 .10-20 U2, 500 / U1, 500 500 65(2) DC - 1 1 0 .10-30 .10-30 U2, 120 120 R, PP, PR only 65(2) DC - 2 only 1 0 .10-25 - U1, 100 - R only 65(2) DC - 2 1 0 .10-25 - U2, 500 - R only 125 50/60 1 1 1 0 .10-20 7.6-20 U1, 1000 500 125 50/60 1 1 1 0 .10-30(3) - U1, 1000 - T only 125(2) 50/60 1 1 1 0 .10-30 - U2, 1000 - R, PP, PR only 125(2) 50/60 1 1 1 1 .10-30 20.1-30 U3, 300(1) 500 R, PP, PR only 120/240 50/60 1 2 2 0 .10-20(3) - U2, 1000 - 120/240 50/60 1 2 2 0 .10-30(3) - U1, 650 - 125/250 50/60 1 2 2 0 .10-20 - U1, 1000 - 250 50/60 1 1 2 0 .10-20 .1-7.5 U1, 500 500 250 50/60 1 1 1 0 .10-7.5 - C1, 1000(4) - 250 50/60 1 2 2 0 .10-20 .10-20 U1, 1000 500 250(2) 50/60 1 2 1 1 .10-30 - U3, 300 - R only 125 400 1 1 2 0 .10-20 - U1, 1000 - 125/250 400 1 2 2 0 .10-20 - U1, 1000 - 250 400 1 2 2 0 .10-20 - U1, 1000 - 250 400 1 1 2 0 .10-7.5 - U1, 1000 - CR/CPP/CPR COMMUNICATIONS EQUIPMENT CIRCUIT BREAKERS 65 DC - 1 only - - .10-30 .10-30 1000 1000 80 DC - 1 only - - .10-30 .10-30 600 600 (1) Non-standard construction. “Fit For Further Use” approval; (2) Non-snap action design; (3) No auxiliary switch available above 20A; (4) With 30A max. series fuse General notes: C – Indicates short circuit test was conducted with series overcurrent protection All supplementary protectors are of the overcurrent (OC) type U – Indicates short circuit test was conducted without series overcurrent protection The family of protectors has been evaluated for end use application for use group (UG) A 1 – Indicates a recalibration was not conducted as part of the short circuit testing The terminals (FW) are suitable for factory wiring only (0) 2 – Indicates a recalibration was performed as part of the short circuit testing The maximum voltage ratings for which the protectors have been tested are shown in the chart 3 – Indicates recalibration was performed along with the dielectric and voltage withstand for “Suitable for Further The current is the amperage range that the protectors have been tested Use” rating The tripping current (TC) for the protectors is either “1” (in the range of 125% to 135% of ampere rating) or “2” (more than 135% of ampere rating) Short Circuit Interrupting Capacity The overload rating (OL) – designates whether the protector has been tested for general use or motor starting applica- 1000 amperes maximum for UL and CSA, 500 amperes maximum for TUV. Consult factory for details. tions. Handle and Body Material 0 – tested at 1.5 times amp rating for general use The handle and upper body material is polycarbonate and the lower body is PET. 1 – tested at 6 times AC rating or 10 times DC rating for motor starting Chemical Resistance The short circuit current rating (SC) – The short circuit rating in amperes following a letter and number designating the Handle and case may be cleaned with detergents or alcohols and should be restricted to outside surfaces only. test conditions and any calibration following the short circuit test is defined below: Organic solvents are not recommended. Special attention should be given when solvents are used to remove excess flux from terminals. No oils or lubricants should be introduced into handle openings or onto bushing threads. AUXILIARY SWITCH RATING IEC, UL, CSA, SEV, VDE, CCC, CE, TÜV Recognized by UL to STD-1077 and UL certified to spacing requirements of IEC 950 for basic and functional insu- Silver lation for front panel mounting. Certified by CSA, file number LR26229 as recognized supplementary protectors, SEV approved, CCC approved, TÜV approved (including screw terminals) to EN60934. TUV approval of unmarked 3.0 amps @ 120 VAC ––– rocker handle option for appliance disconnect requires status of protectors to be indicated on the panel. Only TUV approved part numbers will be marked CE compliant. See shaded areas of part number decision tables for 1.5 amps @ ––– 32 VDC approved configurations and/or consult factory for exceptions and limitations. Shock Gold Withstands 75G without tripping while carrying full rated current per MIL-STD-202, Method 213, Test Condition I. Instant trip breakers are tested at 80% of rated current. .100 amps @ 32 VAC 32VDC Vibration Time delayed units withstand 10G without tripping while carrying full rated current per MIL-STD-202, Method 204, Test Condition A. Instant trip breakers are tested at 80% of rated current. APPROXIMATE WEIGHT PER POLE UL 489A Listed Ounces Grams The CR, CPP and CPR are dimensionally the same as the popular R, PP and PR Snapack products, but provide UL listing to UL489A for Communications Equipment. Available only in single pole with DC trip time delays for series or series with silver auxiliary switch configurations. As a circuit breaker, the CR, CPP or CPR provides Rocker Configuration 0.9 25 communication equipment manufacturers with a UL listed circuit breaker in an extremely compact package that meets the stringent environmental requirements of today’s marketplace. This makes the CR, CPP and CPR ideal Toggle, PP, PR 1.2 32 for switching, transmission and wireless applications. 65 SNAPAK® Series - Specifications http://airpax.sensata.com Paddle Handle Hardware HARDWARE Indicator Plates ON ® SNAPAK toggle handle circuit protectors may be O O F N specified with indicator plates for either vertical or F horizontal mounting.The “ON-OFF/O-I” plate is standard. OFF – A – B Note 1: Vertical Mount Horizontal Mount To allow for installation clearances, the minimum recommended distances between centers of panel openings should be: 0.680 0.680 0.125 0.180 [17.27] [17.27] [3.18] [4.57] RECOMMENDED CENTER DISTANCES FOR PANEL OPENINGS Breaker Type Distance, inches [mm] T11 0.750 [19.05] T21 1.375 [34.93] – 10 & –11 – 20 & –21 PP11 & PR11 0.750 [19.05] Knurled Nut Panel Dress Nut PP21 & PR21 1.375 [34.93] R11 0.805 [20.45] 0.625 0.680 0.125 0.031 R21 1.429 [36.30] [15.88] [17.27] [3.18] [0.79] Note 2: Torque on mounting hardware is not to exceed 25 inch-pounds for 1/2 inch bushings or 15 inch-pounds for 3/8 – 31 – L inch bushings. Hex Nut Locking Ring (Toggle) Mounting Nuts (Toggle) A choice of knurled, dress and hex nuts are available. All three are available in bright nickel. The knurled and dress nuts are Push-Pull & Push-to-Reset Hardware ® also available in a matte black finish. Every SNAPAK comes with a hex nut, but you may order the front panel nuts which 0.534 0.156 will best enhance your design. 0.078 [13.56] [3.96] [1.98] Miscellaneous Hardware ® SNAPAK circuit protectors with 1/2-32 thread may also be equipped with optional locking rings to prevent rotation of the unit after it is installed. 3/8 - 32 Panel Nut Bright Nickel 3/8 - 32 Hex Nut and Panel Nuts The hardware will be supplied with each Push-Pull (PP) 0.500 and Push-to-Reset (PR). 0.156 [12.7] [3.96] 3/8 - 32 Panel Nut This nut when reversed will provide alignment in .437 (11.1) and .468 (11.88) diameter round panel holes. 3/8 - 32 Hex Nut Bright Nickel Note: Tolerance ± .010 [.25] unless noted. Dimensions in brackets [ ] are millimeters. SNAPAK® Series - Hardware 66 SNAPAK® (T/R/PP/PR CR/CPP/CPR) O 5 LINE LINE LINE 4 Fourth Decision HOW TO ORDER ® The ordering code for the SNAPAK circuit protectors may be determined by following the steps in the decision tables shown here. Rocker Step 3: Choose Handle Markings The coding given permits Marked For Vertical Mount-After choice of 3 digit number in step 2 above. Step 1: Choose Letter For Body Color a self-assigning part ON B Black R Black w/ Handle guard ON I I number, with certain G Gray S Gray w/ Handle guard 1 1 First Decision O limitations (due to the O OFF OFF W White T White w/ Handle guard adaptability of magnetic Handle Poles Configurations* Terminals Add “IV” Add “EV” Add “CV” protectors to complex Example: “W...” for English markings. for Intíl. for Combined T Paddle Handle 1 Single Pole † 0 Switch Only (Note E) Quick Connects (leave blank) markings. Example: "-W124EV" markings. circuits), requires a For White Rocker Body (Rocker Style) PP Push-Pull 4 Single Pole †† 1 Series Circuit Protector S Screw Terminals, factory-assigned part Single pole (-1) and series only Marked For Horizontal Mount-After choice of 3 digit number in step 2 above. PR Push-To-Reset 2 Two Pole 3 Shunt Circuit Protector † number. Step: 2: Choose Handle Combinations OFF ON (5th decision, group V - screw R Rocker 5 Two Pole 4 Relay Circuit Protector OFF ON I †† †††† O I terminal option is required CR Rocker ** 5 Series w/ Silver Aux. Switch (w/o Markings) ††† Without Illumination Basic Handle Color when 1st decision "S" is The example shown is the Add “CH” Add “EH” Add “IH” for Combined for English specified) for International CPP Push-Pull ** 6 Series w/ Gold Aux. Switch ††† code for a paddle handle, 01 Black markings. markings. markings. ( ) CPR Push to Reset ** 9 Mixed Construction 2 Pole Only Example “-W06EH” single pole (UL 02 Red Example: “-W06” † UL & CSA Construction construction), series If you have chosen a handle from this table, your 4th Decision and your 06 White †† Non UL & CSA Construction catalog part number are now complete (except if you require “-S” screw circuit protector designed ††† Auxilary Switch is located in the left hand pole (viewed from terminal end) ) 07 Orange terminal option from the 5th Decision Table. †††† Does not meet spacings for many IEC / TUV equipment specs. for operation of a 50/60Hz/ Consult factory for additional information. ( ) Paddle T Handle Color With Illumination Basic Handle Color & Light Choice (w/o Markings) DC circuit. A slow time * Multi-pole units with mixed construction, poles numbered left to right when viewed -01 Black from terminal end. Shunt or relay construction available in pole 2 only, other pole must be a series delay and rating of 5 ( ) 101 Clear w/Neon Note A or switch only construction. -02 Red ( ) 102 Clear w/Green Glow Neon Note A amperes has been **UL 489A listed, available in 1 pole series or series w/silver aux. switch. DC delay only -03 Yellow ( ) 103 Clear w/Red LED Note B indicated. Handle color is -04 Green 104 Clear w/4-8 Vdc Red LED black, and a bright nickel -05 Blue 105 Clear w/8-16 Vdc Red LED knurled nut, vertical mount -06 White ( ) 107 Clear w/Green LED Note B If you have chosen a handle from this table, your 4th Decision is now (ON-OFF) indicator plate 108 Clear w/4-8 Vdc Green LED T11 - 2- 5.00A - 01-11AL- V complete except for hardware options in 5th Decision Table. and locking ring are to be 109 Clear w/8-16 Vdc Green LED 121 Transparent Red w/Neon (Note A) supplied. ( ) Push-Pull PP, CPP and CPR 123 Transparent Red w/Red LED (Note B) -XX No Button Markings desired (not available for CPP & CPR) 124 Transparent Red w/Red LED 4-8 Vdc 2 2 Second Decision 1 To determine the ordering Marked Buttons Available For These Amperages -OA 5 125 Transparent Red w/Red LED 8-16 Vdc code for your particular Frequency & Delay ( ) 161 Translucent White w/Neon Note A 0.1 1 10 ® SNAPAK unit, simply -OB -0 Instant DC-50/60 Hz 162 Translucent White w/ Green Glow Neon (Note A) .25 2.5 15 follow the steps shown, -1 Fast DC-50/60 Hz ( ) 171 Transparent Amber w/Neon Note A 0.5 5 17.5 -OC -2 Slow DC-50/60 Hz ( ) 181 Transparent Smoke Gray w/Neon Note A then fill in the letters and/ .75 7.5 20 -3 Fast w/ Inertia Wheel ( ) 182 Transparent Smoke Gray w/Green Glow Neon Note A or numbers in the boxes. DC-50/60 Hz If you have chosen a handle from this table, your 4th Decision & ( ) 3 Third Decision 183 Transparent Smoke Gray w/Red LED Note B Space is available on the your catalog PN are now complete (except if you require “-S” -4 Slow w/ Inertia Wheel 184 Transparent Smoke Gray w/4-8 Vdc Red LED screw terminal option from the 5th Decision Table.) DC-50/60 Hz circuit breaker label for Rated Current 185 Transparent Smoke Gray w/8-16 Vdc Red LED -41* Fast 400 Hz*** your part number (up to 12 ( ) 187 Transparent Smoke Gray w/Green LED Note B Circuit Breaker Construction Push-to-Reset (PR) -42* Slow 400 Hz* digits). You may then use Transparent Smoke Gray w/4-8 Vdc Green LED 188 -49* Instant 400 Hz Use three numbers to print required -XX No Button Markings Only + your own part number to -51 Fast DC current value between .100 amps 189 Transparent Smoke Gray w/8-16 Vdc Green LED + minimum and 30.0 amps maximum. -52 Slow DC If you have chosen a handle from this table, your 4th Decision and your place an order or as a Example: “-W124” catalog PN are now complete (except if you require “-S” screw terminal -59 Instant DC+ reference for further For example, use: option from the 5th Decision Table.) If you prefer NO markings, then your handle decision is now complete. -61 Fast 50/60 Hz* .100 or 2.00 or 10.0 questions you may have. Slow 50/60 Hz* -62 Switch Only Construction This option does require a -69 Instant 50/60 Hz 5 Fifth Decision -SW Maintained SPST & DPST factory assigned part -S Switch Pole or Special Delay * 20 amps max for 400Hz Note: 20.0 amps max for 400 Hz units. Hardware & Accessories (Notes C and D) number for traceability to **For addition of Inertia Delay an "F" may be added to delay 41, 42, 51, 52, 61, 62 only your drawing or internal ( ) ( ) Group I Group II Indicator Plate Group V Screw Terminal Options + CR, CPP, CPR only available in these delays part number. -00 No Outer Hardware Desired -A Vertical Mount -C SAE 8-32, Upturned Lugs (Tabs) -F M4, Upturned Lugs (Tabs) -10 Black Knurled Nut ( ) Off/On & O/I * Straight Terminal Straight Terminal -11 Bright Nickel Knurled Nut -20 Black Panel Dress Nut Notes: -B Horizontal Mount -D SAE 8-32, Bus-Type Connect (Flat) -H M4, Bus-Type Connect (Flat) -21 Bright Nickel Panel Dress Nut ( ) Off/On & O/I * Straight Terminal Straight Terminal A A neon bulb is provided when specified for 120Vac and 250Vac operation. For operation C When ordering Paddle Handles, you may choose one item from each hardware group to add to 5th -31 Bright Nickel Hex Nut at 120Vac a 33,000 ohm, 1/2 watt external resistor is required. At 250Vac a 100,000 decision if such items are desired. For example, “-11ALCA” would indicate a bright nickel knurled nut, Group III ohm, 1 watt external resistor is required. plus a vertical mount indicator, plus a locking ring, plus #8-32 screw terminal, straight with tabs. Please select a screw terminal option if you *Selection of A or B Indicator Plate -L Locking Ring required for TUV and CCC. selected “S” in Decision 1 B An LED with 750 ft. L @ 20mA is provided in the center of the handle. Maximum power D All units except Rocker units will have (1) hex nut installed as standard hardware for the back of a dissipation @ 25°C is 135mW. Continuous forward current is 20mA. Forward voltage, panel. The choices in the fifth decision table are intended for the front or visible side of the panel and typical, is 1.6v at 20mA. Reverse current, typical, is 100mA @ 3.0 volts. An external are offered for Paddle Handle configuration only. Push-Pull and Push-to-Reset configurations include resistor may be required to limit current to these values. one (1) panel nut and one (1) hex nut as standard hardware. T, V = TÜV and CCC Approved E Switch only — no current overload protection provided. The shaded areas denote CCC (if applicable) and CE compliant options. The V will be added to any part number formed entirely from shaded decisions. F. CCC Approval - If CCC is required on this product, please inform Sensata to have this product If non-shaded areas are selected, the unit will not be approved, nor CE manufacturered in our China facility compliant, but other approvals still apply. 20 amps max rating on units. 67 SNAPAK® Series - Decision Tables 5 O 5 LINE LINE LINE 4 Fourth Decision Rocker Step 3: Choose Handle Markings Marked For Vertical Mount-After choice of 3 digit number in step 2 above. Step 1: Choose Letter For Body Color ON B Black R Black w/ Handle guard ON I I G Gray S Gray w/ Handle guard 1 1 First Decision O O OFF OFF W White T White w/ Handle guard Handle Poles Configurations* Terminals Add “IV” Add “EV” Add “CV” Example: “W...” for English markings. for Intíl. for Combined T Paddle Handle 1 Single Pole † 0 Switch Only (Note E) Quick Connects (leave blank) markings. Example: "-W124EV" markings. For White Rocker Body (Rocker Style) PP Push-Pull 4 Single Pole †† 1 Series Circuit Protector S Screw Terminals, Single pole (-1) and series only Marked For Horizontal Mount-After choice of 3 digit number in step 2 above. PR Push-To-Reset 2 Two Pole 3 Shunt Circuit Protector † Step: 2: Choose Handle Combinations OFF ON (5th decision, group V - screw R Rocker 5 Two Pole 4 Relay Circuit Protector OFF ON I †† †††† O I terminal option is required CR Rocker ** 5 Series w/ Silver Aux. Switch (w/o Markings) ††† Without Illumination Basic Handle Color when 1st decision "S" is Add “CH” Add “EH” Add “IH” for Combined for English specified) for International CPP Push-Pull ** 6 Series w/ Gold Aux. Switch ††† 01 Black markings. markings. markings. ( ) CPR Push to Reset ** 9 Mixed Construction 2 Pole Only Example “-W06EH” 02 Red Example: “-W06” † UL & CSA Construction If you have chosen a handle from this table, your 4th Decision and your 06 White †† Non UL & CSA Construction catalog part number are now complete (except if you require “-S” screw ††† Auxilary Switch is located in the left hand pole (viewed from terminal end) ) 07 Orange terminal option from the 5th Decision Table. †††† Does not meet spacings for many IEC / TUV equipment specs. Consult factory for additional information. ( ) Paddle T Handle Color With Illumination Basic Handle Color & Light Choice (w/o Markings) * Multi-pole units with mixed construction, poles numbered left to right when viewed -01 Black from terminal end. Shunt or relay construction available in pole 2 only, other pole must be a series ( ) 101 Clear w/Neon Note A or switch only construction. -02 Red ( ) 102 Clear w/Green Glow Neon Note A **UL 489A listed, available in 1 pole series or series w/silver aux. switch. DC delay only -03 Yellow ( ) 103 Clear w/Red LED Note B -04 Green 104 Clear w/4-8 Vdc Red LED -05 Blue 105 Clear w/8-16 Vdc Red LED -06 White ( ) 107 Clear w/Green LED Note B If you have chosen a handle from this table, your 4th Decision is now 108 Clear w/4-8 Vdc Green LED T11 - 2- 5.00A - 01-11AL- V complete except for hardware options in 5th Decision Table. 109 Clear w/8-16 Vdc Green LED 121 Transparent Red w/Neon (Note A) ( ) Push-Pull PP, CPP and CPR 123 Transparent Red w/Red LED (Note B) -XX No Button Markings desired (not available for CPP & CPR) 124 Transparent Red w/Red LED 4-8 Vdc 2 2 Second Decision 1 Marked Buttons Available For These Amperages -OA 5 125 Transparent Red w/Red LED 8-16 Vdc Frequency & Delay ( ) 161 Translucent White w/Neon Note A 0.1 1 10 -OB -0 Instant DC-50/60 Hz 162 Translucent White w/ Green Glow Neon (Note A) .25 2.5 15 -1 Fast DC-50/60 Hz ( ) 171 Transparent Amber w/Neon Note A 0.5 5 17.5 -OC -2 Slow DC-50/60 Hz ( ) 181 Transparent Smoke Gray w/Neon Note A .75 7.5 20 -3 Fast w/ Inertia Wheel ( ) 182 Transparent Smoke Gray w/Green Glow Neon Note A DC-50/60 Hz If you have chosen a handle from this table, your 4th Decision & ( ) 3 Third Decision 183 Transparent Smoke Gray w/Red LED Note B your catalog PN are now complete (except if you require “-S” -4 Slow w/ Inertia Wheel 184 Transparent Smoke Gray w/4-8 Vdc Red LED screw terminal option from the 5th Decision Table.) DC-50/60 Hz Rated Current 185 Transparent Smoke Gray w/8-16 Vdc Red LED -41* Fast 400 Hz*** ( ) 187 Transparent Smoke Gray w/Green LED Note B Circuit Breaker Construction Push-to-Reset (PR) -42* Slow 400 Hz* Transparent Smoke Gray w/4-8 Vdc Green LED 188 -49* Instant 400 Hz Use three numbers to print required -XX No Button Markings Only + -51 Fast DC current value between .100 amps 189 Transparent Smoke Gray w/8-16 Vdc Green LED + minimum and 30.0 amps maximum. -52 Slow DC If you have chosen a handle from this table, your 4th Decision and your Example: “-W124” catalog PN are now complete (except if you require “-S” screw terminal -59 Instant DC+ For example, use: option from the 5th Decision Table.) If you prefer NO markings, then your handle decision is now complete. -61 Fast 50/60 Hz* .100 or 2.00 or 10.0 Slow 50/60 Hz* -62 Switch Only Construction -69 Instant 50/60 Hz 5 Fifth Decision -SW Maintained SPST & DPST -S Switch Pole or Special Delay * 20 amps max for 400Hz Note: 20.0 amps max for 400 Hz units. Hardware & Accessories (Notes C and D) **For addition of Inertia Delay an "F" may be added to delay 41, 42, 51, 52, 61, 62 only ( ) ( ) Group I Group II Indicator Plate Group V Screw Terminal Options + CR, CPP, CPR only available in these delays -00 No Outer Hardware Desired -A Vertical Mount -C SAE 8-32, Upturned Lugs (Tabs) -F M4, Upturned Lugs (Tabs) -10 Black Knurled Nut ( ) Off/On & O/I * Straight Terminal Straight Terminal -11 Bright Nickel Knurled Nut -20 Black Panel Dress Nut -B Horizontal Mount -D SAE 8-32, Bus-Type Connect (Flat) -H M4, Bus-Type Connect (Flat) -21 Bright Nickel Panel Dress Nut ( ) Off/On & O/I * Straight Terminal Straight Terminal -31 Bright Nickel Hex Nut Group III Please select a screw terminal option if you *Selection of A or B Indicator Plate -L Locking Ring required for TUV and CCC. selected “S” in Decision 1 T, V = TÜV and CCC Approved The shaded areas denote CCC (if applicable) and CE compliant options. The V will be added to any part number formed entirely from shaded decisions. If non-shaded areas are selected, the unit will not be approved, nor CE compliant, but other approvals still apply. 20 amps max rating on units. 5 SNAPAK® (T/R/PP/PR CR/CPP/CPR)
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the PP11-2-2.00A-OC-V?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers



What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods