Electronics Finder chervon right Manufacturers chervon right S chervon right SL POWER chervon right DC2-40-1AC
About product Specifications Datasheet FAQ

SL POWER DC2-40-1AC

Image of SL POWER DC2-40-1AC

Description

40 W, Double Output, 5 VDC@5 A | 12 VDC@3 A AC-DC Power Supply
DC2-40-1AC

Part Number

DC2-40-1AC

Price

Request Quote

Manufacturer

SL POWER

Lead Time

Request Quote

Category

Circuit Protection »  AC-DC Power Supply

Specifications

Manufacturer

SL Power

Manufacturers Part #

DC2-40-1AC

Brand

Ault

Series

DC2-40

Factory Pack Quantity

1

Cooling Method

Convection

Dimensions

5.00 x 3.00 x 1.50"

Isolation

5300 VDC

Mechanical Style

Open / Enclosed Frame

Mounting

Chassis

Number of Outputs

2

Operating Temperature

- 20 to + 70°C

Output Amps 1

5 A

Output Amps 2

3 A

Output Voltage V1 Nominal

5 VDC

Output Voltage V2 Nominal

12 VDC

Power

40 W

Subcategory

AC-DC Power Supply

Datasheet

pdf file

Ault-flu1-40-2ad-Datasheet1-535510991.pdf

464 KiB

Extracted Text

40W OPEN-FRAME SWITCHING POWER SUPPLIES • Single, Dual and Triple Output Models • Universal AC-Input and DC-Input Models • CE Mark: UL/CSA/EN60950 Approvals • BABT Approvals • Austel CCL Certification • Models with UL544/CSA C22.2-601/EN60-601 Medical Safety Approvals • EN55022/FCC Class B Input Line Filter • 0% Minimum Load Requirement • Over-Current/Short-Circuit Protection • 2-Year Warranty • Minimum 200,000-Hour MTBF CHARACTERISTICS Output Current Output Input Voltage.............................FLU and MDU models, universal Output Voltage Min. Nom. Max. Voltage Line Load Cross- input range 85-265 VAC single Model Output (V) (A) (A) (A) Tol. Reg. Reg. Reg. phase or 100-370 VDC. DC-input AC-DC Singles 85-265 VAC Input models, 36-75 VDC (48V, nominal). Input Line Frequency ................47-440 Hz (ac input models). FLU1-40-1AD V1 5 0.0 8.00 8.00 1.0% 0.1% 0.2% — Input Line Protection.................MOV transient protected (FLU and FLU1-40-2AD V1 9 0.0 4.40 4.40 1.0% 0.1% 0.2% — MDU series). Input line fuse provid- FLU1-40-3AD V1 12 0.0 3.30 3.30 1.0% 0.1% 0.2% — ed on-board. (See Note 1.) FLU1-40-4AD V1 15 0.0 2.70 2.70 1.0% 0.1% 0.2% — EMI Filter...................................Standard. Performance surpasses conducted EMI requirements of FLU1-40-5AD V1 24 0.0 1.70 1.70 1.0% 0.1% 0.2% — EN55022/FCC Class B by 10 dB, typ. FLU1-40-6AD V1 28 0.0 1.40 1.40 1.0% 0.1% 0.2% — DC Output.................................See table. (Note 2.) Continuous Output Power.........40W, maximum. AC-DC Singles To UL544/EN60-601/CSA 22.2-601.1 Leakage Current .......................MDU Series, non-patient contact rat- MDU1-40-1AD V1 5 0.0 8.00 8.00 1.0% 0.1% 0.2% — ing: 500 μA, maximum. MDU1-40-2AD V1 9 0.0 4.40 4.40 1.0% 0.1% 0.2% — Output Voltage Adjust ...............Primary output adjustable ±5%. Auxiliary outputs fixed. MDU1-40-3AD V1 12 0.0 3.30 3.30 1.0% 0.1% 0.2% — Efficiency...................................62-75%, typical (nominal input line MDU1-40-4AD V1 15 0.0 2.70 2.70 1.0% 0.1% 0.2% — voltage, nominal load conditions). MDU1-40-5AD V1 24 0.0 1.70 1.70 1.0% 0.1% 0.2% — Hold-Up Time............................FLU and MDU models: 16 ms (115 MDU1-40-6AD V1 28 0.0 1.40 1.40 1.0% 0.1% 0.2% — VAC input), 32 ms (230 VAC input), minimum, at full load AC-DC Duals 85-265 VAC Input Overload Protection ..................Power-limit circuit. FLU2-40-1AD V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — Short-Circuit Protection.............Continuous. V2 +12 0.0 2.00 3.00 5.0% 0.5% 3.0% 4.0% Over-Voltage Protection............Primary output only. Soft Start...................................Standard on all models. FLU2-40-2AD V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — Design Topology .......................Flyback converter with current-mode V2 +15 0.0 1.70 2.00 5.0% 0.5% 3.0% 4.0% control. FLU2-40-3AD V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — Frequency of Operation ............40 kHz (fixed). V2 +24 0.0 1.00 1.50 5.0% 0.5% 3.0% 4.0% Hi-Pot Isolation..........................FLU Series: 5300 VDC, input-to-out- FLU2-40-4AD V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — put for one minute. (Note 3.) V2 +28 0.0 1.00 1.00 5.0% 0.5% 3.0% 4.0% MDU Series: 5700 VDC, input-to-out- FLU2-40-5AD V1 5(ISO) 0.0 6.00 6.00 1.0% 0.2% 1.0% — put for one minute. (Note 3.) V2 5(ISO) 0.0 2.00 2.00 3.0% 0.5% 1.0% 1.0% Noise, Ripple and Spike ...........1% peak-to-peak, maximum. (See FLU2-40-6AD V1 12(ISO) 0.0 2.00 3.00 1.0% 0.2% 1.0% — Note 5.) V2 12(ISO) 0.0 1.00 2.00 3.0% 0.5% 1.0% 1.0% Temperature Range ..................-20°C to +70°C. Output Power De-Rating...........De-rate output power and current FLU2-40-7AD V1 15(ISO) 0.0 1.50 2.50 1.0% 0.2% 1.0% — linearly 2%/°C from +50°C to +70°C. V2 15(ISO) 0.0 1.20 2.00 3.0% 0.5% 1.0% 1.0% Temperature Coefficient............±0.05%/°C over the entire operating AC-DC Duals To UL544/EN60-601/CSA 22.2-601.1 temperature range. Relative Humidity......................0 to 95%, non-condensing. MDU2-40-1AD V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — Altitude ......................................0 to 10,000 feet. V2 +12 0.0 2.00 3.00 5.0% 0.5% 3.0% 4.0% Cooling......................................Convection cooling is adequate. MDU2-40-2AD V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — Moving air is recommended for oper- V2 +15 0.0 1.70 2.00 5.0% 0.2% 3.0% 4.0% ation in a confined area. MDU2-40-3AD V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — Storage Temperature ................-40°C to +85°C. V2 +24 0.0 1.00 1.50 5.0% 0.2% 3.0% 4.0% Storage Humidity ......................0 to 95%, non-condensing. MDU2-40-4AD V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — Mean Time Between Failures ...>200,000 hours. (Note 6.) V2 +28 0.0 1.00 1.00 5.0% 0.5% 3.0% 4.0 POWER GENERAL 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com 08 40W OPEN-FRAME SWITCHING POWER SUPPLIES Output Current Output Output Current Output Output Voltage Min. Nom. Max. Voltage Line Load Cross- Output Voltage Min. Nom. Max. Voltage Line Load Cross- Model Output (V) (A) (A) (A) Tol. Reg. Reg. Reg. Model Output (V) (A) (A) (A) Tol. Reg. Reg. Reg. DC-DC Duals 36-75 VDC Input AC-DC Triples To UL544/EN60-601/CSA 22.2-601.1 DC2-40-1AC V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — * V2 +12 0.0 2.00 3.00 5.0% 0.5% 3.0% 4.0% MDU3-40-1AD V2 +12 0.0 1.50 3.00 5.0% 1.0% 3.0% 4.0% V3 -12 0.0 0.50 0.70 5.0% 0.2% 1.0% 1.0% DC2-40-2AC V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — V2 +15 0.0 1.70 2.00 5.0% 0.2% 3.0% 4.0% V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — * MDU3-40-2AD V2 +12 0.0 1.50 3.00 5.0% 1.0% 3.0% 4.0% DC2-40-3AC V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — V3 -5 0.0 1.00 1.00 3.0% 0.2% 1.0% 1.0% V2 +24 0.0 1.00 1.50 5.0% 0.2% 3.0% 4.0% V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — DC2-40-4AC V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — † MDU3-40-3AD V2 +15 0.0 1.20 2.00 5.0% 1.0% 3.0% 4.0% V2 +28 0.0 1.00 1.00 5.0% 0.5% 3.0% 4.0% V3 -15 0.0 0.50 0.60 5.0% 0.2% 1.0% 1.0% AC-DC Triples 85-265 VAC Input V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — § V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — MDU3-40-4AD V2 +24 0.0 0.75 1.50 5.0% 1.0% 3.0% 4.0% * FLU3-40-1AD V2 +12 0.0 1.50 3.00 5.0% 1.0% 3.0% 4.0% V3 -12 0.0 0.50 0.70 5.0% 0.2% 1.0% 1.0% V3 -12 0.0 0.50 0.70 5.0% 0.2% 1.0% 1.0% DC-DC Triples 36-75 VDC Input V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — * FLU3-40-2AD V2 +12 0.0 1.50 3.00 5.0% 1.0% 3.0% 4.0% * DC3-40-1AC V2 +12 0.0 1.50 3.00 5.0% 1.0% 3.0% 4.0% V3 -5 0.0 1.00 1.00 3.0% 0.2% 1.0% 1.0% V3 -12 0.0 0.50 0.70 5.0% 0.2% 1.0% 1.0% V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — † V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — FLU3-40-3AD V2 +15 0.0 1.20 2.00 5.0% 1.0% 3.0% 4.0% * DC3-40-2AC V2 +12 0.0 1.50 3.00 5.0% 1.0% 3.0% 4.0% V3 -15 0.0 0.50 0.60 5.0% 0.2% 1.0% 1.0% V3 -5 0.0 1.00 1.00 3.0% 0.2% 1.0% 1.0% V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — § V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — FLU3-40-4AD V2 +24 0.0 0.75 1.50 5.0% 1.0% 3.0% 4.0% † DC3-40-3AC V2 +15 0.0 1.20 2.00 5.0% 1.0% 3.0% 4.0% V3 -12 0.0 0.50 0.70 5.0% 0.2% 1.0% 1.0% V3 -15 0.0 0.50 0.60 5.0% 0.2% 1.0% 1.0% V1 5(ISO) 0.0 5.00 6.00 1.0% 0.2% 0.5% — V1 +5 0.0 3.00 5.00 1.0% 0.2% 1.0% — FLU3-40-5AD V2 12(ISO) 0.0 0.30 0.50 4.0% 0.5% 1.0% 1.0% § DC3-40-4AC V2 +24 0.0 0.75 1.50 5.0% 1.0% 3.0% 4.0% V3 12(ISO) 0.0 0.30 0.50 4.0% 0.5% 1.0% 1.0% V3 -12 0.0 0.50 0.70 5.0% 0.2% 1.0% 1.0% V1 5(ISO) 0.0 5.00 6.00 1.0% 0.2% 0.5% — FLU3-40-6AD V2 15(ISO) 0.0 0.30 0.50 4.0% 0.5% 1.0% 1.0% * Peak output current rating = 5.0A (<60 seconds, duty cycle <10%). V3 15(ISO) 0.0 0.30 0.50 4.0% 0.5% 1.0% 1.0% † Peak output current rating = 3.0A (<60 seconds, duty cycle <10%). § Peak output current rating = 2.0A (<60 seconds, duty cycle <10%). Notes Model Selection Guide 1. Replace the input line fuse with the same type and rating. FLU 2-- 40 1 A D Recommended: 2A/250V slow-blow fuse. 2. The sum of primary and auxiliary output currents from triple Series Input Voltage output models -1AD through -4AD must not exceed 5.0A. FLU=AC Input D=85-265 VAC 3. Hi-pot isolation is 2200 VDC from the input of the supply to MDU=AC Input C=36 to 75 VDC ground for 60 seconds. (UL544/IEC601 Safety) Construction 4. All measurements are made directly at the terminals of the DC=DC Input A=Open PCB power supply. Number of Outputs B=L-Bracket 5. Peak-to-peak and RMS metering equipment must have a 20 C=Full Enclosure MHz frequency response with probes and cables that main- Output Power (W) tain a frequency response of 20 Hz to 20 MHz. Output rip- Output Voltage (Model) ple and spikes are measured directly at the output terminals of the power supply with a 0.1 μF ceramic capacitor. The probe ground band must make direct contact with the output of nominal load; load current is then varied +40%/-30% of nominal while other outputs return or common terminal to prevent erroneous noise mea- are held at nominal load conditions. surements. 10. Cross-regulation is tested by changing the load on the primary output from 50% to 6. MTBF is calculated using the parts stress method in MIL- 100% of nominal load while measuring the voltage change on the auxiliary output HDBK 217F (ground benign, TA = +25°C). under test. 7. Output voltage tolerance is measured under nominal load 11. The FLU1-40, FLU2-40 and FLU3-40 series are approved to UL1950 (File E140439), current conditions. CSA22.2 No. 234 (File LR52335), EN60950/IEC950/DIN VDE 0805 (TÜV Licenses R679206, R0097621, R9071501), and Austel CCL (Certificate A92/PS/004). 8. Line regulation is measured under nominal load conditions 12. The FLU3-40 series has BABT/EN41003 approval ((NS/4199/123/R/604674). as the input voltage is varied from 85 to 265 VAC (ac-input models) or from 36 to 75 VDC (dc-input models). 13. The MDU1-40, MDU2-40 and MDU3-40 series are approved to UL544 (File E151357), CSA 22.2 No. 601.1 (File LR52335) and EN60-601/IEC601-1/DIN VDE 0750 (TÜV 9. Load regulation is measured at 115 VAC or 230 VAC. For Licenses R9271474, R9271475, R9271476). single output models, load regulation is measured while out- 14. The DC2-40 and DC3-40 series are approved to UL1950 (File E140439), CSA22.2 No. put current is varied from 0% to 100% of full load. With mul- tiple output models, the output under test is brought to 60% 234 (File LR52335), and EN60950/IEC950/DIN VDE 0805 (TÜV License R9071501). POWER GENERAL 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com 9 40W OPEN-FRAME SWITCHING POWER SUPPLIES FLU/MDU/DC 40W SERIES A. Dimensions shown are in inches. B. Tolerances = 0.00 ±0.01 inch. 0.000 ±0.005 inch. C. P1 input connectors are Molex 26-62-4030. The mating con- nector combines Molex housing 43061-0003 and crimp ter- minal 08-70-1030. D. P2 output connectors for the 40W series, except for models 5 and 6 of the FLU3-40 series, are Molex 26-60-4060. The mating connector combines Molex housing 43061-0006 and crimp terminal 08-70-1030. Models 5 and 6 of the FLU3-40 series use Molex 26-60-4080 for the P2 connector. The mat- ing connector uses Molex housing 43061-0008 and crimp terminals 08-70-1030. Pin-Out FLU2-40 FLU2-40 FLU3-40 FLU3-40 Pin FLU1-40 MDU1-40 Models 1-4 Models 5-7 MDU2-40 DC2-40 Models 1-4 Models 5-6 MDU3-40 DC3-40 1 V1 V1 V2 +V1 V2 V2 V2 +V2 V2 V2 (ISO) (ISO) 2 V1 V1 V1 +V1 V1 V1 V1 - V2 V1 V1 (ISO) (ISO) 3V1 V1 V1 - V1 V1 V1 V1 +V1 V1 V1 (ISO) (ISO) 4 Return Return Common - V1 Common Common Common +V1 Common Common (ISO) (ISO) 5 Return Return Common - V2 Common Common Common - V1 Common Common (ISO) (ISO) 6 Return Return N/C +V2 N/C N/C V3 - V1 V3 V3 (ISO) (ISO) 7 N/A N/A N/A N/A N/A N/A N/A +V3 N/A N/A (ISO) 8 N/A N/A N/A N/A N/A N/A N/A - V3 N/A N/A (ISO) POWER GENERAL 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com 10 40W POWER SUPPLY ENCLOSURES L-Bracket To order, change the part number suffix from AD to BD or from AC to BC. 1. Material is 0.036-inch cold-rolled steel (20 AWG). 2. Finish is zinc and clear chromate plating. 3. Dimensions are in inches. 4. Tolerances = 0.00 ±0.01 0.000 ±0.005 L-Bracket and Cover To order full enclosure, change the part number suffix from AD to CD or from AC to CC. 1. Material is 0.036-inch cold-rolled steel (20 AWG). 2. Finish is zinc and clear chromate plating. 3. Dimensions are in inches. 4. Tolerances = 0.00 ±0.01 0.000 ±0.005 POWER GENERAL 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com 11

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the DC2-40-1AC?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

DC Power Connectors DC plug adptor 2.1mm

product

Plug-In Adapter Single-OUT 12V 0.5A 7.35W BA500120500003BK

product

Plug-In Adapter Single-OUT 12V 0.5A 7.35W BA500120500003NK

product

Battery Chargers BCM2306150003A

product

Battery Chargers BCM2306150003N

product

Battery Chargers BCM2510120003A