SL POWER GLD140D
Specifications
Manufacturer
SL Power
Manufacturers Part #
GLD140D
Selling Alternatives
GLD140DG
Brand
Condor
Series
GLD140
Factory Pack Quantity
10
Application
General Purpose
Connection Type
Molex/JST
Convection Rating
140 W
Cooling Method
Air-Cooled, Convection
Dimensions
8.50 x 4.50 x 1.95"
Efficiency
85%
Environmental Conditions
General Purpose
Industry
Industrial
Input Type
AC
Mechanical Style
Open / Enclosed Frame
Number of Outputs
4
Operating Temperature
0 to +70°C, derate linearly to 50% power from 50-70°C
Output Amps 1
16 A
Output Amps 2
4 A
Output Amps 3
4 A
Output Amps 4
0.75 A
Output Voltage V1 Nominal
5 V
Output Voltage V2 Nominal
24 V
Output Voltage V3 Nominal
12 V
Output Voltage V4 Nominal
-12 V
Package Type
Open Frame
Power
180 W
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
SL POWER GLD140 SERIES GLD140 Gold Performance Medical Switchers 140 Watt Power Supply 140 Watt Multiple Output Measures: 8.50 x 4.50 x 1.95” FEATURES: • Compact size (4.5" x 8.5" x 1.95") • Power factor corrected to IEC 1000-3-2 Class A • Documented FMEA, WCA and EMC test results • EMI compliance to CISPR11, FCC Class B, IEC601-1-2 • Approved to UL2601, IEC601-1 and CSA 22.2 No. 601.1-M90 and EN60601: 1990 • marked to LVD SPECIFICATIONS: Ac Input Thermal Shutdown 90-264 Vac, 47-63 Hz single phase. Provided as a standard feature. Designed to protect unit from Output Power prolonged over temperature. Continuous output power 140 W with unrestricted convection Power Fail cooling, 180 W with 150 LFM of air. TTL / CMOS compatible output goes low (<0.5 V) 10 ms before Input Current output voltage drops more than 4% below nominal voltage upon Active Power Factor Correction circuitry assures compliance loss of ac power. with IEC1000-3-2, Class A. Maximum input current at minimum Power Good input voltage and full load is 3.0 A. TTL / CMOS compatible output rises high 100 to 300 ms after V1 Efficiency reaches regulation and should assure that sufficient energy is 73 – 85 % at full rated load, nominal input voltage, depending on stored in the input section to provide normal power fail / model and load distribution. shutdown. Hold-up Time Inhibit 26 ms total. 16 ms minimum from loss of ac input at full load until Inhibit signal when pulled to the V1 output common will inhibit all activation of the power fail signal. Output voltages remain within output voltages. specified regulation limits for an additional 9 ms minimum after Fan Output power fail activates. An additional thermally controlled 12 Vdc, 250 mA output suitable Overload Protection for powering a dc fan is included in all models (Factory installed Fully protected against short circuit and output overload. Short cover with fan makes this output unavailable). circuit protection is cycling type power limit. EMI/EMC Compliance Output Noise All models include built-in EMI filtering to meet the following 0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. requirements: Measured with noise probe directly across output terminals of EMC SPECIFICATION COMPLIANCE LEVEL the power supply. Conducted Emissions EN55011, Class B; FCC Class B Transient Response Static Discharge EN61000-4-2, 6 kV contact 8 kV air 500 µs typical response time for return to within 0.5% of final RF Field Susceptibility EN61000-4-3, 3V/meter value for a 45% load step from any load greater than 10% of full Fast Transients / Bursts EN61000-4-4, 2 kV, 5 kHz rated load, ∆i/∆t< 0.2 A µs. Maximum voltage deviation is 3.5%. Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Remote Sense Conducted RF Susceptibility EN61000-4-6, 3V Provided as a standard feature on V1 and V2. Voltage Sags & Surges EN61000-4-11 Overvoltage Protection Line Frequency Harmonics EN61000-3-2 Class A Built in on V1, 2 and 3 outputs. EMC Compliance for Gold Series Voltage Adjustment Magnetic Emissions - Emissions will not exceed the limits of the Factory set to specified voltage with user adjustable potentiom- Army curve in MIL-STD-461D, RE101 when measured at 7 cm eter on V1, 2 and 3. User can adjust V1, 2 and 3 at least ±5% of from 30 Hz - 100 kHz over all nominal inputs and at full rated load. nominal output voltage. Leakage Current Output Regulation 70 µA under normal conditions 120 Vac @ 60 Hz Regulation for all outputs is the maximum deviation from initial Single fault conditions 280 µA, 264 Vac @ 50 Hz. set point under all line and load conditions. Initial set tolerance is SAFETY AGENCY APPROVALS: measured with all outputs at 50 % of full rated load. All models are Certified to be in compliance with the No Load Turn-On/Standby applicable requirements of UL2601-1, CSA-C22.2 No. 601.1, A minimum load of 3 A on V1 is required for proper regulation. If IEC 601-1/60601-1. not met, no degradation of reliability will occur. DESIGN VERIFICATION DOCUMENTS Temperature Coefficient The “Gold” series has undergone rigorous review and design 0.03% / °C typical on all outputs. analysis. The following product documentation is available upon Input Protection request: 1. Failure Mode and Effects analysis (FMEA), 2. DVT Internal ac fuses provided on both lines on all units. Data, 3. EMC / Susceptibility test results. Inrush Current Inrush is limited by internal thermistors. The inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37 A. Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com 58 power@sager .com http://power.sager.com/sl-power-GLD140-power-supply.html http://power.sager.com SL POWER GLD140 SERIES 140 Watt Power Supply Measures: 8.50 x 4.50 x 1.95” GLD140 Medical Switchers 140 Watt Multiple Output Medical Output Output Output Output Set Line OVP Ripple Model No. Voltage Current (A) Current (B) Tolerance Load Trip and Noise GLD140A 1 +5.0 V 16 A 20 A 1% 1% 6.2 ± 0.3 V 1% 2 +12 V 6 A 8 A 1% 1% 14 ± 0.7 V 1% 3 12 V (C) 4 A 5 A 1% 1% 14 ± 1.2 V 1% 4 -12 V 0.75 A 1.2 A 2.2% 1% ------- 1% GLD140B 1 +5.0 V 16 A 20 A 1% 1% 6.2 ± 0.3 V 1% 2 +12 V 6A 8 A 1% 1% 14 ± 0.7 V 1% 3 5 V (C) 4 A 5 A 1% 1% 6.3 ± .5 V 1% 4 -12 V 0.75 1.2 A 2.2% 1% ------- 1% GLD140C 1 +5.0 V 16 A 20 A 1% 1% 6.2 ± 0.3 V 1% 2 +12 V 6 A 8 A 1% 1% 14 ± 0.7 V 1% 3 15 V (C) 4 A 5 A 1% 1% 18 ± 1.2 V 1% 4 -15 V 0.75 A 1.2 A 2.2% 1% ------- 1% GLD140D 1 +5.0 V 16 A 20 A 1% 1% 6.2 ± 0.3 V 1% 2 +24 V 4 A 6 A 1% 1% 27 ± 1 V 1% 3 12 V (C) 4 A 5 A 1% 1% 14 ± 1.2 V 1% 4 -12 V 0.75 1.2 A 2.2% 1% ------- 1% GLD140E 1 +5.0 V 16 A 20 A 1% 1% 6.2 ±0.3 V 1% 2 +24 V 4 A 6 A 1% 1% 27 ± 1 V 1% 3 15 V (C) 4 A 5 A 1% 1% 18 ± 1.2 V 1% 4 -15 V 0.75 A 1.2 A 2.2% 1% ------- 1% GLD140F 1 +5.0 V 16 A 20 A 1% 1% 6.2 ± 0.3 V 1% 2 +15 V 5 A 7 A 1% 1% 18 ± 1.2 V 1% 3 12V (C) 4 A 5 A 1% 1% 14 ± 1.2 V 1% 4 -12 V 0.75 A 1.2 A 2.2% 1% ------- 1% GLD140G 1 +5.0 V 16 A 20 A 1% 1% 6.2 ± 0.3 V 1% 2 +3.3 V 10 A 12 A 1% 1% 4.2 ± 0.4 V 1% 3 12 V (C) 4 A 5 A 1% 1% 14 ± 1.2 V 1% 4 -12 V 0.75 A 1.2 A 2.2% 1% ------- 1% Output Current for Individual Outputs: A. Output current for unrestricted natural convection. B. Output current with 150 LFM forced air convection or peak current rating. C. Isolated (floating) output may be referenced positive or negative. GLD140 MECHANICAL SPECIFICATIONS INPUT: JI MOLEX P .C.B. HEADER P/N 39-30-2056 PIN 1) AC GROUND PIN 2) N/C PIN 3) AC NEUTRAL PIN 4) N/C PIN 5) AC LINE MATING CONNECTOR MOLEX P/N: HOUSING 39-01-4051, CONTACT 39-00-0164 SIGNALS: J2 AMP P.C.B. HEADER P/N: 641215-6 PIN 1) +SENSE PIN 2) -SENSE PIN 3) POWER FAIL PIN 4) POWER GOOD PIN 5) COMMON PIN 6) INHIBIT MATING CONNECTOR AMP P/N: HOUSING 770602-6, CONTACT 770666-2 OUTPUT: J3 MOLEX P .C.B. HEADER P/N: 39-29-9206 PINS 1) +V3out PINS 2) -V4out PINS 3,12,13) COMMON PINS 4) +V2 SENSE PINS 5,14,15) +V2out PINS 6-8, 16) COMMON PINS 9,10,19,20) +V1out PINS 11) +V3 RTN PINS 17,18) COMMON MATING CONNECTOR MOLEX P/N: HOUSING 39-01-2200, CONTACT 39-00-0164 FAN: J5 AMP P.C.B. HEADER P/N 641215-2 PINS 1) FAN RTN PINS 2) +FAN MATING CONNECTOR AMP P/N: HOUSING 770602-2, CONTACT 770666-2 Environmental Operating Non-operating Specification o o T0 emperature (A) 0 to 5 C5 -40 to +8 C A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. HH umidity (A) 0H to 95% R 0 to 95% R B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 Sg hock (B) 20 40 g orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. pk pk C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, Altitude -t 500 to 10,000 ft -500 to 40,000 f total 6 shocks. 2 2 Vg ibration (C) 1.5 , 0.003 g /g Hz 5 , 0.026 g /Hz rms rms Specifications are subject to change without notice. It is r Condor D esponsibility of each customer to thor .C. Power Supplies oughly test each pr , Inc., 2311 Statham P oduct and part number under their unique parameters and envir arkway, Oxnard, CA 93033 onments to ensure a product will work properly and reliably. 800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com 59 Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/sl-power-GLD140-power-supply.html http://power.sager.com
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the GLD140D?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods