SL POWER GLM110-524
Specifications
Manufacturer
SL Power
Manufacturers Part #
GLM110-524
Industry Aliases
GLM110-524
Selling Alternatives
GLM110-524G
Brand
Condor
Series
GLM110
Factory Pack Quantity
10
Cooling Method
Air-Cooled, Convection
Dimensions
7.00 x 4.25 x 1.30"
Mechanical Style
Open / Enclosed Frame
Mounting
Chassis
Number of Outputs
2
Operating Temperature
0 to + 50°C
Output Amps 1
3.2 A
Output Amps 2
1.5 A
Output Voltage V1 Nominal
24 VDC
Output Voltage V2 Nominal
5 VDC
Power
110 W
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
GLC110 Commercial/GLM110 Medical 110 Watt Global Performance Switchers GLOBAL PERFORMANCE SWITCHERS FEATURES: • Cost-effective power source • Single- and dual-output units • Low height (1.30”) • 2-year warranty • Power fail signal standard • Commercial Approved to UL60950-1, EN60950-1, CSA22.2 No. 950-95 3rd Ed. • Medical Approved to UL2601-1, EN60601-1, CSA-C22.2 No. 601.1 • Complies with EN61000-3-2 Class A • RoHS Compliant Model Available (G suffix) SPECIFICATIONS Ac Input 90-264 Vac, 47-63 Hz single phase. Transient Response Input Current Maximum input current at 90 Vac, 60 Hz with full rated output load not to Main Output: 500 μs typical response time for return to within 0.5% of final value exceed 2.9 A. for a 50% load step change, ∆i/∆t<0.2 A/μs. Maximum voltage deviation is 3.5%. Startup/shutdown overshoot less than 3%. Turn-On Time less than 1 second at 120 Hold-up Time Vac, 25. 20 ms minimum from loss of ac input at full load, nominal line (120 Vac). Overvoltage Protection Output Power Built in on main output. Normal continuous output power is 75 W for unrestricted natural convection, Efficiency or 110 W with 26 cfm air flow. 72-85% depending on model. Output Regulation Load regulation on dual output models is measured by ±40% load change Input Protection from 60% rated load and input voltage change from minimum to maximum Internal ac fuse provided on all units. Designed to blow only if a catastrophic ratings. failure occurs in the unit. Output #1 requires 1A minimum load for proper regulation of other outputs. Inrush Current Initial set tolerance is measured with all outputs at 60% of full rated load. Inrush limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37 A. Load regulation for single-output models measured by changing load from 5% to 50% load or 50% to full load in either direction. Temperature Coefficient Voltage Adjustment 0.03%/°C typical on all outputs. Output #1 adjustment is ±5%. Note: output #1 must not be more than 1% EMI/EMC Compliance below nominal to achieve full output regulation on output #2. High voltage All models include built-in EMI filtering to meet the following emissions require- settings may degrade the reliability of the unit due to excessive power ments: dissipation in some outputs. EMI SPECIFICATIONS COMPLIANCE LEVEL Overload Protection Conducted Emissions GLC110 EN55022 Class B; FCC Class B Fully protected against short circuit and output overload. Short circuit protec- Conducted Emissions GLM110 EN55011 Class B: FCC Class B tion is cycling type power limit. Factory set to begin power limiting at 120 W. Static Discharge EN61000-4-2, 6 kV contact, 8 kV air RF Field Susceptibility EN61000-4-3, 3 V/meter Output Noise Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Line Frequency Harmonics EN61000-3-2 Class A POWER FAIL Power fail signal is TTL or CMOS compatible (output goes low <0.5 V) 5 ms Commercial Safety before output voltage drops more than 4% below nominal voltage upon All GLC models are approved to UL60950-1, CSA22.2 No. 950-95 3rd Ed, and loss of AC power. The signal is factory set to trip on 84 to 94 Vac brown-out EN60950-1. depending upon incoming line impedance and distortion. Other settings are Medical Safety available to the user through adjustment of built in potentiometer (consult All GLM models are approved to UL2601-1, CSA-C22.2 No. 601.1, EN60601-1. factory for assistance). Output will stay low for 20 ms minimum. O All specifications are typical at nominal input, full load at 25 C unless otherwise stated Commercial Medical RoHS Output Output Output Output Forced Air Output Peak Noise P-P OVP Total Regu- Model Model Suffix* No. Minumum Normal (A) (B) lation ( C ) GLC110-212 GLM110-212 G 1 +12 V 1 A 6.3 A 9.1 A 9.5 A 100 mV 15.6 ± 1.1 V 2% 2 -12 V 0 A 2.5 A 3 A 4 A 120 mV 2% GLC110-215 GLM110-215 G 1 +15 V 1 A 5 A 7.3 A 7.7 A 120 mV 18.5 ± 1.5 V 2% 2 -15 V 0 A 2.5 A 3 A 4 A 150 mV 2% GLC110-524 GLM110-524 G 1 +24 V 1 A 3.2 A 4.6 A 4.75 A 200 mV 28 ± 2.5 V 2% 2 +5 V 0 A 1.5 A 2 A 2.5 A 50 mV 6.2 ± 0.6 V 2% GLC110-12 GLM110-12 G 1 12 V 0 A 6.3 A 9.1 A 9.5 A 120 mV 15.6 ± 1.1 V 2% GLC110-15 GLM110-15 G 1 15 V 0 A 5 A 7.3 A 7.7 A 150 mV 18.5 ± 1.5 V 2% GLC110-24 GLM110-24 G 1 24 V 0 A 3.2 A 4.6 A 5 A 240 mV 28 ± 2.5 V 2% * Add “G” suffix to part number for RoHS compliant model. Contact factory for availability. A. Rating with unrestricted convection cooling. Total power not to exceed 75 W; no output can exceed rated current. B. Rating with 26 cfm forced air cooling. Total power not to exceed 110 W. C. To maintain regulation V1 current must be at least 1/5 of V2. V1 must not be adjusted more than 1% below nominal and have at least 10% of rated load. GLC110/GLM110 MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Derated output current and toal Temperature (A) 0 to 50° -40 to +85°C output power by 2.5% per °C above 50°C. Humidity (A) 0 to 95% RH 0 to 95% RH B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to Shock (C) 20 g 40 g 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 pk pk hr./axis non-operating. Altitude -500 to 10,000 ft -500 to 40,000 ft C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 2 2 Vibration (B) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz rms’ rms’ orthogonal axes, total 6 shocks. SL Power Electronics Corp, 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: info@slpower.com Rev. 02/11/10. Data Sheet © 2010 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the GLM110-524?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods