SL POWER GLM50-15
Specifications
Manufacturer
SL Power
Manufacturers Part #
GLM50-15
Industry Aliases
GLM50-15
Selling Alternatives
GLM50-15G
Brand
Condor
Series
GLM50
Factory Pack Quantity
20
Dimensions
4.25 x 2.50 x 1.25"
Mechanical Style
Open / Enclosed Frame
Mounting
Chassis
Number of Outputs
1
Operating Temperature
0 to + 50°C
Output Amps 1
3.3 A
Output Voltage V1 Nominal
15 VDC
Power
50 W
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
GLC50 Commercial/GLM50 Medical 50 WATT GLOBAL PERFORMANCE SWITCHERS GLOBAL PERFORMANCE SWITCHERS Features: D C P o w e r S u p p l i e s • Cost-effective power source • Universal input 90-264 Vac • 2-year warranty • Compact (4.25” x 2.50” x 1.25”; meets 1U applications) • Overload and overvoltage protection • Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) • Commercial UL/CSA/IEC60950-1, EN60950 approvals • Medical UL/EN/IEC60601-1, CSA22.2 No. 601, • RoHS compliant models available (G suffix) • marked to LVD SPECIFICATIONS Ac Input Temperature Coefficient 90-264 Vac, 47-63 Hz single phase.. 0.03%/°C typical on all outputs. Input Current Output Noise Maximum input current at 120 Vac, 60 Hz with full rated output load: 1.5 A 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. Hold-Up Time 15 ms minimum from loss of ac input at full load, nominal line (115 Vac). Transient Response 500 μs typical response time for return to within 0.5% of final value for a 50% load Output Power step change. ∆i/∆t<0.2 A/μs. Maximum voltage deviation is 3.5%. Startup/shut- 50 W continuous, 60 W peak. Peak ratings are for 60 s maximum duration, down overshoot less than 3%. 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits. Voltage Adjustment Built-in potentiometer adjusts V1 ±5%. Output Regulation To maintain specified regulation on multi-output models, output #1 load EMI/EMC Compliance power must be at least 1/5th of, and not greater than 5 times output #2 load All models include built-in EMI filtering to meet the following emissions require- power. ments: Overload Protection EMI SPECIFICATIONS COMPLIANCE LEVEL Fully protected against short circuit and output overload. Short circuit pro- tection is cycling type power limit on outputs 1 & 2; foldback type on output Conducted Emissions GLC EN55022 Class B; FCC Class B 3. Recovery after fault is automatic. See output ratings chart for additional Conducted Emissions GLM EN55011 Class B; FCC Class B notes or conditions. Static Discharge EN61000-4-2, 6 kV contact, 8 kV air RF Field Susceptibility EN61000-4-3, 3 V/meter Efficiency Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz 70-85% at full rated load, nominal input voltage, depending on model and Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. load distribution. Minimum Load Commercial Leakage Current Operating without minimum load will not degrade reliability, but regula- 160 μA 254 Vac @ 60 Hz input (with no deviations). tion may be affected. Multiple output models require 20% minimum load Commercial Safety on V1 for proper regulation. Single models require 5% minimum load when All GLC models are approved to UL1950, CSA22.2 No. a transient load greater than 30% is applied or removed, but will operate 234 Level 3, IEC950 and EN60950. without load. Medical Leakage Current Input Protection 100 μA 264 Vac @ 60 Hz input (normal conditions). Internal ac fuse provided. Designed to blow only if a catastrophic failure oc- curs in the unit—fuse does not blow on overload or short circuit. Medical Safety Inrush is limited by internal thermistors. Inrush at 240 Vac, All GLM50 models are approved to UL/EN/IEC60601-1, CSA22.2 No. 601. averaged over the first ac half-cycle under cold start conditions will not exceed 37 A. O All specifications are typical at nominal input, full load at 25 C unless otherwise stated Commercial Medical Minimum Total Model Model Output No. Output Current Load (B) OVP Setpoint Noise P-P Regulation (A) GLC50A GLM50A 1 +5.05 V 4 A 0.8 A 6.2 ± 0.6 V 50 mV 2% 2 +12 V 2.5 A 120 mV +10%,-5% 3 -12 V 0.2 A 120 mV 3% GLC50B GLM50B 1 +5.05 V 4 A 0.8 A 6.2 ± 0.6 V 50 mV 2% 2 +15 V 2.5 A 150 mV +10%,-5% 3 -15 V 0.2 A 150 mV 3% GLC50D GLM50 D 1 +5.05 V 4 A 0.8 A 6.2 ± 0.6 V 50 mV 2% 2 +24 V 1.5 A 240 mV +10%,-5% 3 -12 V 0.2 A 120 mV 3% GLC50G GLM50G 1 +3.3 V 4 A 0.8 A 4.2 ± 0.6 V 33 mV 2% 2 +12 V 2.5 A 120 mV +10%-5% 3 -12 V 0.2 A 120 mV 3% GLC50-3.3 GLM50-3.3 1 3.3 V 8 A 0.2 4.2 ± 0.6 V 66 mV 2% GLC50-5 GLM50-5 1 5.1 V 8 A 0.4 6.2 ± 0.6 V 75 mV 2% GLC50-12 GLM50-12 1 12 V 4.2 A 0.2 14 ± 1.1 V 120 mV 2% GLC50-15 GLM50-15 1 15 V 3.3 A 0.16 18.5 ± 1.5 V 150 mV 2% GLC50-24 GLM50-24 1 24 V 2.1 A 0.1 28 ± 2.5 V 240 mV 2% GLC50-28 GLM50-28 1 28 V 1.8 A 0.09 34.5 ± 2.8 V 280 mV 2% GLC50-48 GLM50-48 1 48 V 1.1 A 0.05 54 ± 3.0 V 480 mV 2% Notes: A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. To maintain specified regulation on multi-output models, output #1 load power must be at least 1/5th of, and not greater than 5 times output #2 load power. C. Add “G” suffix to model number for RoHS compliant model. GLC50 MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING Temperature (A) 0 TO 50°C -40 to +85°C A. Units should be allowed to warm up/operate under non-condensing condi- tions before application of power. derate output current and total output Humidity (A) 0 to 95% RH 0 to 95% RH power by 2.5% per °C above 50°C. Shock (B) 20 g 40 g pk pk B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal Altitude -500 to 10,000 ft -500 to 40,000 ft axes, total 6 shocks. C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 2 2 Vibration (C) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz rms’ rms’ orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. SL Power Electronics Corp, 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com. Rev. 1/07. Data Sheet © 2007 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Condor accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the GLM50-15?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods