SL POWER GPC140-28-T
Specifications
Manufacturer
SL Power
Manufacturers Part #
GPC140-28-T
Brand
Condor
Series
GPC140
Factory Pack Quantity
10
Cooling Method
Air-Cooled, Convection
Dimensions
8.50 x 4.50 x 2.12"
Efficiency
70%
Mechanical Style
Open / Enclosed Frame
Mounting
Chassis
Number of Outputs
1
Operating Temperature
0 to + 50°C
Output Amps 1
5 A
Output Voltage V1 Nominal
28 VDC
Power
140 W
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
GPC55 Commercial/GPM55 Medical 55 Watt Global Performance Switchers GLOBAL PERFORMANCE SWITCHERS FEATURES: D C P o w e r S u p p l i e s • Wide-range ac input 85-264 Vac • 2-year warranty • Conducted EMI complies with FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) • Commercial Approved to UL1950, IEC950 and CSA22.2-234 L3 • Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601 • Complies with EN61000-3-2 Class A • Single and multiple outputs • marked to LVD • RoHS Compliant Model Available (G suffix) SPECIFICATIONS Ac Input Output Noise 85-264 Vac, 47-63 Hz single phase. 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. Input Current Transient Response Maximum input current at 120 Vac, 60 Hz with full rated output load: 1.7 A Main output—500 μs typical response time for return to within 0.5% of final value Hold-Up Time for a 50% load step change. ∆i/∆t<0.2 A/μs. Maximum voltage deviation is 3.5%. 20 ms minimum from loss of ac input at full load, nominal line (115 Vac). Startup/shutdown overshoot less than 3%. Output Power Voltage Adjustment 55 W continuous, 70 W peak. Peak ratings are for 60 s maximum duration, Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2. 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits. EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions require- Overload Protection ments: Fully protected against short circuit and output overload. Short circuit protec- EMI SPECIFICATIONS COMPLIANCE LEVEL tion is cycling type power limit on outputs 1 & 2; foldback type on outputs 3 & 4. Recovery after fault is automatic. See output ratings chart for Conducted Emissions GPC55 Static EN55022 Class B; FCC Class B additional notes or conditions. Factory set to begin power limiting at ap- Conducted Emissions GPM55 EN55011 Class B; FCC Class B proximately 75 W. Static Discharge EN61000-4-2, 6 kV contact, 8 kV air RF Field Susceptibility EN61000-4-3, 3 V/meter Overvoltage Protection Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz Main outputs: 124% + 12% Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Efficiency Line Frequency Harmonics EN61000-3-2 Class A 70% at full rated load, nominal input voltage, depending on model and load distribution. Commercial Leakage Current Input Protection 0.7 mA 254 Vac @ 60 Hz input. Internal ac fuse provided. Designed to blow only if a catastrophic failure oc- Commercial Safety curs in the unit. Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950. UL file Inrush Current #E135803 commercial; CSA #LR46516 all models. All dc outputs are SELV under Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start normal and single fault conditions. conditions will not exceed 34 A. Medical Leakage Current Temperature Coefficient 35 μA 254 Vac @ 60 Hz input. 0.03%/°C typical on all outputs. Medical Safety Environmental Approved to UL2601, CSA22.2 No. 601 Level 3 and IEC601. UL file E116994; CSA Designed for 0 to 50°C operation at full rated output power; derate output #LR46516. The output(s) are intended for safety earthed Signal Output and current and total output power by 2.5% per °C above 50°C. See Environmen- Intermediate Circuits only. The output(s) are not acceptable for patient connection tal and Packaging Specifications on next page. without additional isolation. All dc outputs are SELV under normal and single fault conditions. O All specifications are typical at nominal input, full load at 25 C unless otherwise stated Commercial Medical Output Output Output Total Model Model Output No. Output Minimum Maximun Peak Noise P-P Regulation (A) GPC55A GPM55A 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +12 V 0 A 3 A 5 A 120 mV 2% 3 +12 V 0 A 1 A 1.2 A 120 mV 3% 4 -12 V 0 A 1 A 1.2 A 120 mV 3% GPC55B GPM55B 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +12 V 0 A 3 A 5 A 120 mV 2% 3 -5 V 0 A 1 A 1.2 A 50 mV 3% 4 -12 V 0 A 1 A 1.2 A 120 mV 3% GPC55C GPM55C 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +15 V 0 A 3 A 5 A 150 mV 2% 3 -5 V 0 A 1 A 1.2 A 50 mV 3% 4 -15 V 0 A 1 A 1.2 A 150 mV 3% GPC55D GPM55D 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +24 V 0 A 1.5 A 5 A 240 mV 2% 3 +12 V 0 A 1 A 1.2 A 120 mV 3% 4 -12 V 0 A 1 A 1.2 A 120 mV 3% GPC55E GPM55E 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +24 V 0 A 1.5 A 5 A 120 mV 2% 3 +15 V 0 A 1 A 1.2 A 150 mV 3% 4 -15 V 0 A 1 A 1.2 A 150 mV 3% GPC55F GPM55F 1 +5 V 0.7 A 6 A 8 A 50 mV 2% 2 +12 V 0 A 3 A 5 A 120 mV 2% 3 +15 V 0 A 1 A 1.2 A 150 mV 3% 4 -15 V 0 A 1 A 11 150 mV 3% GPC55-5 GPM55-5 1 5 V 0 A 11 A 14 A 50 mV 2% GPC55-12 GPM55-12 1 12 V 0 A 4.7 A 5.8 A 120 mV 2% GPC55-15 GPM55-15 1 15 V 0 A 3.7 A 4.7 A 150 mV 2% GPC55-24 GPM55-24 1 24 V 0 A 2.3 A 2.9 A 240 mV 2% GPC55-28 GPM55-28 1 28 V 0 A 2.0 A 2.4 A 280 mV 2% GPC55-48 1 48 V 0 A 1.5 A 1.5 A 480 mV 2% A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. Add “G” suffix to model to indicate RoHS compliant moel. GPC55/GPM55 MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING A. Units should be allowed to warm up/operate under non-condensing Temperature (A) See individual Specs -40 to +85°C conditions before application of power. Humidity (A) 0 to 95% RH 0 to 95% RH B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 Shock (B) 20 g 40 g orthogonal axes, total 6 shocks. pk pk Altitude -500 to 10,000 ft -500 to 40,000 ft C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 2 2 Vibration (C) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz rms’ rms’ hr./axis non-operating. SL Power Electronics Corp.. 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 5/08. Data Sheet © 2008 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Condor accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the GPC140-28-T?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods