SL POWER MAX-403-0512
Specifications
Manufacturer
SL Power
Manufacturers Part #
MAX-403-0512
Brand
Condor
Series
MAX-400
Factory Pack Quantity
9999
Cooling Method
Air-Cooled
Dimensions
11.50 x 5.00 x 2.50"
Efficiency
80%
Isolation
50 VDC
Mechanical Style
Open / Enclosed Frame
Mounting
Chassis
Number of Outputs
3
Operating Temperature
0 to + 50°C
Output Amps 1
70 A
Output Amps 2
10 A
Output Amps 3
6 A
Output Voltage V1 Nominal
5 VDC
Output Voltage V2 Nominal
12 VDC
Output Voltage V3 Nominal
- 12 VDC
Power
400 W
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
400, 500 WATTS MULTIPLE OUTPUT MAX-400 MAX-500 MTC-500 Option F Option C STANDARD MAX SERIES Option V MODEL PWR OUTPUT #1 OUTPUT #2 OUTPUT #3 OUTPUT #4 MAX-403-0512 400 +5V @ 70A +12V @ 10/16A pk -12V @ 6A MAX-503-0512 500 +5V @ 80A +12V @ 10/16A pk -12V @ 10A Featuring: MAX-504-1205 500 +5V @ 80A +12V @ 10/16A pk -12V @ 10A 5.2V @ 2A 3 • Over 3.5 watts/in power density MAX-504-1212 500 +5V @ 80A +12V @ 10/16A pk -12V @ 10A 12V @ 2A MAX-504-1224 500 +5V @ 80A +12V @ 10/16A pk -12V @ 10A +24V @ 2A • 80% overall efficiency MAX-504-1252 500 +5V @ 80A +12V @ 10/16A pk -5.2V @ 10A 12V @ 2A • VMEbus and Multibus II system compatibility TELECOM MTC SERIES • Meets international safety agency MODEL PWR OUTPUT #1 OUTPUT #2 OUTPUT #3 requirements MTC-503-0512 500 +5V @ 70A +12V @ 10A -12V @ 10A • All outputs regulated ±1% MTC-503-0515 500 +5V @ 70A +15V @ 8A -15V @ 8A • High peak currents for motor starting • System air or self-cooling options VMEbus and Multibus compatibility is High-current auxiliary outputs provide • AC automatic line selection option only one feature of this series. You’ll find regulation characteristics for proper switchers to power up to 80 Amps of operation of line drivers, network inter- logic and four hard disk drives — with faces, and RS232-type outputs. And, up to 16 Amps peak current to meet you can upgrade power output by 25% peripheral startup needs. without redesigning for a larger power You’ll find the outputs you need for supply. ISDN, LAN, T1 applications and for standard voice and data networks. Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com 400, 500 WATTS 11.5” x 5”x 2.5” MAX-400, 500 MTC-500 MAX, MTC-500 MAX, MTC-500 with Option F 4.5 lbs - 2.0 kgs 5.2 lbs - 2.4 kgs Dimensions: Inches Millimeters SPECIFICATIONS: ALL MODELS INPUT AC Input: 90-132 Vac/180-264 Vac, 47 to 63 Hz. User selectable. See option “A” for automatic Option “G”, DC Power Good: Provides a TTL “1” open collector when output #1 is above 4.6 line selection. Internally fused for 12 A. V nominal. Not available if option “P” is selected. Inrush: Cold start AC current is less than 80 A at 115 Vac and 20 A at 230 Vac. Limited by Option “P”, AC Power Fail: Provides TTL “0” 5 ms before output voltage goes out of thermistor. regulation band upon loss of AC power. VMEbus compatible, provides 48 mA sink current Holdup Time: 16 ms minimum after removal of power, at nominal line, full load. capability. Not available if option “G” is selected. Efficiency: 80% typical. Option “V”, Fan/Cover Assembly: Low profile, end venting cover with integral ball-bearing Brownout Protection: Holds regulation to 85 Vac or 170 Vac. fan. OUTPUT Consult factory for other available options. Adjustability: User adjustable ±5% minimum. Line & Load Reg: ±1% over AC input range and 0 to 100% load change. Output #1 requires AC INPUT minimum load of 10%. FUNCTION 115 VAC 230 VAC CONNECTORS Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater. Input Select Short Open 0.250 Male Fastons Remote Sense (Output #1): Compensates for 250 mV total line drop. Open sense lead protection. TB1- (L) Line Line 1 Barrier strip Temperature Coefficient: 0.02% per degree C. #6-32 screws TB1- (N) Neutral Line 2 Stability: 0.1% over 8 hours after 30 minutes warm-up. 3/8 centers. TB1- ( ) Safety Ground Safety Ground Transient Response (Output #1): Output voltage returns to within 1% in less than 500 µs for a 50% load change. Peak transient does not exceed 5%. DC OUTPUT Overload Protection: All outputs are protected against overload and short circuit. Automatic FUNCTION LOCATION NOTES CONNECTOR recovery upon removal of fault. Overvoltage Protection (Output #1): Protects load against power supply induced overvoltage. Output #1 Terminal marked +V Main Output Bus bars Trip point is factory set so that output voltage cannot exceed 136% of nominal. #1/4-20 screws Terminal marked COM Rtn (Common) Remote Inhibit: Contact closure to the negative sense line drops output power to nominal Output #2 TB2-3 zero. TB2-4 Rtn (Common) Reverse Voltage: Protected against reverse voltage up to supply current rating. Output #3 TB2-5 Barrier Strip ENVIRONMENTAL TB2-4 Rtn (Common) #6-32 screws Thermal Protection: Shuts down power supply if overheated. Automatic recovery. 3.8” centers Temperature Range: 0° to 50°C at full ratings. Derate to half power at 70°C. Output #4* TB2-1 (+) Safety Agencies: Most models are approved to UL1950; CSA 22.2 #234; IEC 950 and TÜV (If provided) TB2-2 (–) EN60950, Class 1 SELV., CE 72/23/EEC/93/68EEC (low voltage directive). Conducted RFI: Meets FCC Part 15, Subpart J, Class A; EN55022 Class B; CISPR 22 Class B. *Rtn connected to common only if output is polarized in product selection chart Cooling: 30 CFM required to achieve full ratings. STATUS AND CONTROL Output Isolation: Isolated from ground 50 Vdc. FUNCTION LOCATION NOTES CONNECTOR Remote Sense J1-1 (+S) Output #1 Sense AMP MTA type OPTIONS: #640456-4 pin J1-2 (-S) Output #1 Sense Rtn Option “A”, AC Auto-Range: Automatically selects proper AC line voltage range to enable header (locking) AC Power Fail or J1-3 (PF) Reference to J1-2 power operation at either 115 or 230 Vac without user intervention. Option “C”, Cover: Limits contact with power supply interior. DC Power Good* Option “F”, Fan/Cover Assembly: Cover with integral ball-bearing fan provides proper cooling Inhibit J1-4(1H) Short to J1-2 to achieve full ratings at 50°C ambient temperature. *Optional function Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the MAX-403-0512?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers





What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods