SL POWER MB120S18K01
Specifications
Manufacturer
SL Power
Manufacturers Part #
MB120S18K01
Industry Aliases
Brand
Condor
Series
MB120S
Factory Pack Quantity
1
Application
General Purpose
Compliance
BF Compliant
Connection Type
Molex/JST
Convection Rating
100 W
Convection Rating Temp
50°C
Cooling Method
Air-Cooled, Convection
Dimensions
4.00 x 2.00 x 1.4"
Efficiency
94%
Environmental Conditions
General Purpose
Industry
Medical
Input Type
AC - Class I
Input Voltage Nominal
100-240 VAC
Isolation
4000 VAC
Mechanical Style
Open / Enclosed Frame
Mounting
Chassis Mount
Number of Outputs
1
Operating Temperature
-10 to +70°C (-20°C startup, see derating curve)
Output Amps 1
6.6 A
Output Voltage V1 Nominal
18 V
Package Type
Open Frame
PFC
Yes
Power
120 W
Protection Level
2xMOPP
Standard Packaging Size
2 x 4
Subcategory
AC-DC Power Supply
Weight
.225
Datasheet
Extracted Text
MB120S 120W Single Output Medical Series Features 2” x 4” x 1.25” Package, Ideal for 1U Applications 10-year Life design with Premium E-Caps 100 Watts convection cooled Class B Conducted and Radiated EMI performance BF Isolation Type Rated Designed to meet new IEC 60601-1-2 th 4 Edition EMC requirements [Approvable ] to AAMI ES/CSA C22.2 rd /EN/IEC60601-1 3 Edition 2 x MOPP Isolation <0.5 W Standby Power 3 Year Warranty Description A superior performance 120 Watt AC to DC power supply designed for next generation medical applications. Feature rich and highly efficient, MB120 product family can easily fit in a 1U chassis and provides 100 Watts of convection power. Input & output and internal temperature monitoring/alarms are features of the MB120 family. All models are CE marked to low voltage directive and rd approved to AAMI ES/CSA C22.2 No./EN/IEC60601-1, 3 edition. The design takes into consideration the pending international th 1 release of the new IEC 60601-1-2, 4 Edition EMC requirements . With low leakage current performance, the power supplies are BF rated. Model Selection 4 Model Output Current Efficiency Ripple & Initial Total Load OVP 2 5 Number Volts 200 LFM Airflow Convection Noise Set Point Regulation Threshold MB120S12K01 12V 10.0A 8.3A 92% 1% ± 2% ± 1% 14.4 ± 1.2V MB120S15K01 15V 8.0A 6.6A 93% 1% ± 2% ± 1% 18 ± 1.5V MB120S18K01 18V 6.6A 5.5A 94% 1% ± 2% ± 1% 21.6 ± 1.8V MB120S24K01 24V 5.0A 4.1A 94% 1% ± 2% ± 1% 28.8 ± 2.4V Notes: 1) Power supply is tested according to Table 9 – Test Specification for Enclosure Port Immunity for Professional and Home Health care. 2) Part number suffix to include “K” for Class-1 AC input 4) Efficiency, Typical at 230Vac, 25°C. See Charts below for load conditions. 5) Measured at 25C using 6 inch twisted pair wires with noise probe directly across output terminals, and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. www.slpower.com 1 MB120S 120W Single Output Medical Series General Specifications 80-264Vac, single phase, 47 – 63 Hz. (Safety Approved to 90-264Vac). Start up voltage for 20mS min. from loss of AC input , full load, 25°C. AC Input Hold-up Time full power is 90Vac, power derates at 85Vac, see table below. Over Load 115% - 180% of rated output current value. Hiccup Input Current 2.0A at 115Vac, 1A at 230Vac Mode, Auto-recovery Protection (OCP) 40Arms Maximum within a half line cycle, Short Circuit Short across the output terminals will not cause damage cold start at 25C, 230Vac See application Inrush Current to the unit. Hiccup Mode , Auto-recovery Protection (SCP) note. Over Voltage Latches off when output voltage is with range as shown Input Fuses 3.15A, 250Vac, line and neutral inputs in table. Requires AC Power cycle to reset Protection (OVP) Power shuts down at temperature of 70℃ (typical) at Earth Leakage Over Temperature < 150 µA@264Vac, 60Hz input, NC full load, without forced air. Hiccup Mode , Auto- <300 µA@264Vac, 60Hz input, SFC Current Protection (OTP) recovery <90 µA@264Vac, 60 Hz input, NC, also Outputs protected against momentary reverse current Patient Leakage Output Reverse suitable for BF rating less than 20A peak for less than 10mS with 0.5A average. Current (Output to Sustained reverse current at high levels may damage Voltage Protection Earth) unit. Input-Output: 4000Vac, 2 x MOPP No Load Input <0.5W Isolation Input-Ground: 1500Vac, 1 x MOPP Power Output-Ground: 1500Vac, 1 x MOPP Turn-On & -10°C to +70°C. 92% - 94% typical at 120/240Vac, 25°C. See Efficiency Operating Turn on Temperature = -20°C at >=115Vac, allowing 30 chart for additional details seconds with 50-100% load for stabilization. Temperature 120W with 200 LFM airflow cooling, 100W convection cooling, -10C to 50°C ambient. Storage -40°C to +85°C Output Power Power derates by 50% from 50C to 70C. See Temperature chart below. 500S typ. response time for return to within Operating: -500m to 3000m Transient Response 1% of final value for 25%-75%-25% load Altitude Non-operating: -500 to 40,000 feet change Ripple and Noise 1% pk-pk Relative Humidity 5% to 95%, non-condensing Operating: Half-sine shock waveform. Impact Acceleration: 20g, Pulse duration: 11mS. Shock 12V to 24Vdc. See models chart for part Cycles: 3 times per axis in X,Y, Z direction Output Voltage numbering. Non-Operating: Half-sine shock waveform. Impact (IEC 60068-2-27) Acceleration: 40g, Pulse duration: 6mS Cycles: 3 times per direction on 3 axes (X,Y. Z) Operating: Sinusoidal Frequency: 10-500Hz, Impact Acceleration: 1g, Sweep rate: 1 octave/min Voltage Adjustability Cycles: 10 times per axis in X, Y, Z direction Vibration No voltage adjust potentiometer for higher Random Vibration: (IEC 60068-2-6) 2 reliability Operating: 0.003g /Hz, 1.224grms overall, 3 axes, 10 (IEC 60068-2-64) min per axis, 1-500Hz. 2 Non-Operating: 0.02g /Hz, 3.1grms overall, 3 axes, 1 hour per axis, 20-500 Hz 572,500 hours @ 115/230Vac, 25°C 1 Second at 115Vac. Turn On Time MTBF Telcordia, Issue 3, Ground Benign. >10 Years in use condition of 40°C ambient, at 12h/day, Rise Time <30mS, Typical (Load dependent) E-Cap Life 261 days/year. Additional information on other use profiles available on request. www.slpower.com 2 MB120S 120W Single Output Medical Series General Specifications (continued) <4% overshoot at turn-on, <1% overshoot at Overshoot IPC 610 Class 2 turn-off, under all conditions. rd IEC 60601-1, 3 Edition ANSI/AAMI ES60601-1 (2008) CAN/CSA – C22.2 No 60601-1 (2005) Safety Standards DEMKO EN60601-1:2006 Designed to meet China Safety Doc. No. GB4943.1-2011 at 3Km, Tropical Standard at 40°C, 93% RH at 120 hours. Total Load ±1.0 % for all models. Weight 225g, typical Regulation W: 2.0” x L: 4.0” x H: 1.25” Minimum Load Not required. Dimensions W: 50.8mm x L: 101.6mm x H: 31.8mm EMI/EMC Compliance EN55011/22: Class B, FCC Part 15. Class B: 6db margin typical Conducted Emissions EN55011/22: Class B, FCC Part 15. Class B: 3db margin typical Radiated Emissions Harmonic Current Emissions IEC61000-3-2: Class A Voltage Fluctuations & Flicker IEC 61000-3-3 IEC61000-4-2: Level 4, 8kV Contact Discharge, 15kV air discharge, Criteria A. Electro Static Discharge Immunity th Also meets proposed IEC60601-1-2, 4 edition, Table 9 IEC61000-4-3: Level 3, 10V/m, Criteria A. 80MHz-1000 MHz and 3V/m 1.4Ghz to 2.7 Radiated RF EM Fields Susceptibility th GHz. 80% AM at 1kHz. Also meets proposed IEC60601-1-2, 4 edition, Table 9 Proximity Fields from RF wireless communications th [IEC60601-1-2: 4 edition, Table 9 Equipment Rated Power Frequency magnetic fields IEC61000-4-8: Level 5, 30A/m, 50/60 Hz IEC61000-4-4: Level 3, 2KV, 100Khz rep rate, 40A (PS Output), Criteria A Electrical Fast Transients /Bursts Also meets proposed IEC60601-1-2, 4th edition standard, Table 5 & 6. IEC61000-4-5: Level 3, +/-1kV DM, +/-2kV CM, Criteria A Surges Line to Line (DM) and Line to Ground (CM) Also meets proposed IEC60601-1-2, 4th edition standard, Table 5. IEC61000-4-6: 3V/m & 10 V/m – 0.15 to 80Mhz and 10V/m in ISM and amateur radio Conducted Disturbances induced by RF Fields bands between 0.15 MHz and 80 MHz, 80% AM at 1 KHz Also meets proposed IEC60601-1-2, 4th edition standard, Table 5 & 6 & 8. IEC61000-4-8: Level 4 (30A/m), Criteria A Rated Power Frequency Magnetic Fields Test th Also meets proposed IEC60601-1-2, 4 edition standard, Table 9 enclosure port. IEC61000-4-11: 100% dip for 10mS, at 0°, 45°, 90°, 135°, 180°, 225°, 270° and 315°, Voltage Dips Criteria A; 60% dip for 100mS, Criteria B; 30% dip for 500mS (25/30 cycles) 1, and 0° th for 500mS, Criteria A. Also meets proposed IEC60601-1-2, 4 edition standard, Table 5. Enclosure Port Immunity to RF wireless IEC61000-4-3 communications equipment Notes: Performance criteria are based on EN55024. According to the standards, performance criteria are defined as following: A – Normal performance during and after the test B – Temporary degradation, self-recoverable C – Temporary degradation, operator intervention required to recover the operation D – Permanent damage www.slpower.com 3 MB120S 120W Single Output Medical Series Isolation Specifications Parameter Conditions/Description Min Nom Max Units Input/Ground 1 MOPP Insulation Safety Rating Input/Output 2 MOPP Output/Ground 1 MOPP Input/Ground 1500 Vac Electric Strength Test Voltage Input/Output 4000 - - Vac Output/Ground 1500 Vac Mechanical Drawing Connector Information www.slpower.com 4 MB120S 120W Single Output Medical Series Efficiency Information Efficiency vs Output Power - MB120S12E 95% 93% 91% 89% 87% 85% 83% 80 Vac 115Vac 81% 230Vac 264 Vac 79% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Percent Output Power - % Note: Above efficiency curves are typical at 25C convection cooling, after 1 hour warm up time. Efficiency may vary with lower run time prior to measurement. Efficiency vs Output Power - MB120S15E 95% 93% 91% 89% 87% 85% 83% 80 Vac 115Vac 81% 230Vac 264 Vac 79% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Percent Output Power - % Note: Above efficiency curves are typical at 25C convection cooling, after 1 hour warm up time. Efficiency may vary with lower run time prior to measurement. www.slpower.com 5 Efficiency (%) Efficiency (%) MB120S 120W Single Output Medical Series Efficiency vs Output Power - MB120S18E 95% 93% 91% 89% 87% 85% 83% 80 Vac 115Vac 81% 230Vac 264 Vac 79% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Percent Output Power - % Note: Above efficiency curves are typical at 25C convection cooling, after 1 hour warm up time. Efficiency may vary with lower run time prior to measurement. Efficiency vs Output Power - MB120S24E 95% 93% 91% 89% 87% 85% 83% 80 Vac 115Vac 81% 230Vac 264 Vac 79% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Percent Output Power - % Note: Above efficiency curves are typical at 25C convection cooling, after 1 hour warm up time. Efficiency may vary with lower run time prior to measurement. www.slpower.com 6 Efficiency (%) Efficiency (%) MB120S 120W Single Output Medical Series Power Derating Information Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com 7
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the MB120S18K01?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers





What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods