SL POWER ME30A0502C01
Specifications
Manufacturer
SL Power
Manufacturers Part #
ME30A0502C01
Brand
Ault
Series
ME30
Factory Pack Quantity
1
Dimensions
3.80 x 2.20 x 1.30"
Mechanical Style
External
Mounting
Wall Mount
Number of Outputs
1
Operating Temperature
- 20 to + 70°C
Output Amps 1
4 A
Output Voltage V1 Nominal
5 VDC
Power
20 W
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
ME30 20 to 30W Single Output External Power Medical Series Features Meets UL/EN/IEC60601-1-2, 4th edition for * EMC Approved to EN/IEC/UL60601-1, 3rd edition 2 MOPP input-output isolation Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 30W of AC-DC Power Universal Input 90-264Vac Input Range Desktop and Wall-Plug versions Meets EN55011/CISPR11, FCC Part 15.109 Class B Conducted & Radiated Emissions, with >6db margin E-cap life of >8 years >1,000,000 hours MTBF IP22 Rated Enclosure 3 Year Warranty Description A high performance AC to DC external power supply family designed for medical applications. The ME30A Medical Series low power external AC-DC power supplies are approved to safety EN/IEC/UL60601-1, 3rd edition with isolation levels * which satisfy the 2 MOPP requirements and designed to UL/EN/IEC60601-1-2, 4th edition for EMC . The ME30A Series models will operate at universal input range of 90 to 264Vac over the wide temperature range of -20°C to +70°C, delivering full rated output power up to +40°C and applicable output power derating at 70°C. These models are available in desktop and wall-plug versions, include an IP22 rating per IEC60529 for the enclosure, and output cable terminated at a variety of output connectors. *Consult Factory for Table 9 compliance information. Model Selection Overvoltage Output Input Model Output Output Ripple & Line Load Number Volts Current Power Noise¹ Regulation Regulation Trip Range Connector Configuration ME30A0503F01 5.0V 4.00A 20W 75mV pk-pk ±1% ±5% 5.75V-7.75V ME30A0903F01 9.0V 3.00A 27W 90mV pk-pk 11.7V-16.2V ±1% ±5% 2.5 x 5.5 x Class I ME30A1203F01 12.0V 2.50A 30W 120mV pk-pk ±1% ±5% 14.4V-16.8V 9.5mm Desktop, ME30A1503F01 15.0V 2.00A 30W 150mV pk-pk ±1% ±5% 18.0V-21.0V Straight Barrel IEC60320 C14 Type, center ME30A1803F01 18.0V 1.67A 30W 180mV pk-pk ±1% ±5% 21.6V-25.2V Receptacle positive ME30A2403F01 24.0V 1.33A 30W 240mV pk-pk 28.8V-33.6V ±1% ±5% ME30A4803F01 48.0V 0.63A 30W 480mV pk-pk ±1% ±5% 55.0V-60.0V ME30A0503N01 5.0V 4.00A 20W 75mV pk-pk ±1% ±5% 5.75V-7.75V ME30A0903N01 9.0V 3.00A 27W 90mV pk-pk ±1% ±5% 11.7V-16.2V 2.5 x 5.5 x Class II ME30A1203N01 12.0V 2.50A 30W 120mV pk-pk 14.4V-16.8V ±1% ±5% 9.5mm Desktop, ME30A1503N01 15.0V 2.00A 30W 150mV pk-pk ±1% ±5% 18.0V-21.0V Straight Barrel IEC60320 C8 Type, center ME30A1803N01 18.0V 1.67A 30W 180mV pk-pk ±1% ±5% 21.6V-25.2V Receptacle positive ME30A2403N01 24.0V 1.33A 30W 240mV pk-pk 28.8V-33.6V ±1% ±5% ME30A4803N01 48.0V 0.63A 30W 480mV pk-pk ±1% ±5% 55.0V-60.0V www.slpower.com ME30 Rev 2.1 9-NOV-17 1 ME30 20 to 30W Single Output External Power Medical Series Model Selection (continued) Model Output Output Ripple & Line Load Overvoltage Output Input Number Volts Current Power Noise¹ Regulation Regulation Trip Range Connector Configuration ME30A0503Q01 5.0V 4.00A 20W 75mV pk-pk ±1% ±5% 5.75V-7.75V ME30A0903Q01 9.0V 3.00A 27W 90mV pk-pk ±1% ±5% 11.7V-16.2V 2.5 x 5.5 x Class II ME30A1203Q01 12.0V 2.50A 30W 120mV pk-pk 14.4V-16.8V ±1% ±5% 9.5mm Desktop, ME30A1503Q01 15.0V 2.00A 30W 150mV pk-pk ±1% ±5% 18.0V-21.0V Straight Barrel IEC60320 C18 Type, center ME30A1803Q01 18.0V 1.67A 30W 180mV pk-pk ±1% ±5% 21.6V-25.2V Receptacle positive ME30A2403Q01 24.0V 1.33A 30W 240mV pk-pk 28.8V-33.6V ±1% ±5% ME30A4803Q01 48.0V 0.63A 30W 480mV pk-pk ±1% ±5% 55.0V-60.0V ME30A0503B01 5.0V 4.00A 20W 75mV pk-pk ±1% ±5% 5.75V-7.75V ME30A0903B01 9.0V 3.00A 27W 90mV pk-pk ±1% ±5% 11.7V-16.2V Class II Wall- 2.5 x 5.5 x Plug, ME30A1203B01 12.0V 2.50A 30W 120mV pk-pk 14.4V-16.8V ±1% ±5% 9.5mm Interchangeabl ME30A1503B01 15.0V 2.00A 30W 150mV pk-pk ±1% ±5% 18.0V-21.0V Straight Barrel e Blades (North Type, center ME30A1803B01 18.0V 1.67A 30W 180mV pk-pk ±1% ±5% 21.6V-25.2V American Blade positive ME30A2403B01 24.0V 1.33A 30W 240mV pk-pk ±1% ±5% 28.8V-33.6V included)² ME30A4803B01 48.0V 0.63A 30W 480mV pk-pk 55.0V-60.0V ±1% ±5% ME30A0503C01 5.0V 4.00A 20W 75mV pk-pk ±1% ±5% 5.75V-7.75V ME30A0903C01 9.0V 3.00A 27W 90mV pk-pk ±1% ±5% 11.7V-16.2V 2.5 x 5.5 x Class II Wall- ME30A1203C01 12.0V 2.50A 30W 120mV pk-pk ±1% ±5% 14.4V-16.8V 9.5mm Plug, Fixed ME30A1503C01 15.0V 2.00A 30W 150mV pk-pk 18.0V-21.0V Straight Barrel ±1% ±5% North American Type, center ME30A1803C01 18.0V 1.67A 30W 180mV pk-pk ±1% ±5% 21.6V-25.2V Blades³ positive ME30A2403C01 24.0V 1.33A 30W 240mV pk-pk ±1% ±5% 28.8V-33.6V ME30A4803C01 48.0V 0.63A 30W 480mV pk-pk 55.0V-60.0V ±1% ±5% Notes: 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. For 5V and 6V models, values listed are typical, 100mV pk-pk maximum with 0.1μF ceramic and 47μF low ESR capacitors used at measurement point. 2. Order blade kit KT-1027K for other blades (EU. UK, Australia) 3. For EU fixed blades, replace “C” in the model number with “M”, for UK blades, replace “C” with “G”, for Australia blades, replace “C” with “H”. 4. All specifications are typical at nominal input, full load, at 25°C ambient unless noted. 5. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (ME30B1203F01). General Specifications Parameter Specification Parameter Specification AC Input 100-240Vac, ±10%, 47-63Hz, 1∅ Turn On Time Less than 700mS @115Vac, full load 115Vac: 1.2A, 230Vac:0.6A 20mS min., at full Load, 100Vac input Input Current Hold-up Time Overtemperature Will shutdown upon an overtemperature Inrush Current 264Vac, cold start: will not exceed 40A condition, auto-recovery. Protection F1, F2: 2.0A, 250Vac fuses (line & neutral Input Fuses Overload Protection 130 to 180% of rating, Hiccup Mode lines) provided on all models Earth Leakage Short Circuit <500μA@264Vac, 60Hz, NC Hiccup Mode, auto recovery. <1mA@264Vac, 60Hz, SFC Current (Input to Ground) Protection Patient Leakage <100μA@264Vac, 60Hz, NC Overvoltage Hiccup mode, see models chart for trip <500µA@264Vac, 60Hz, SFC ranges. Current (Output to Earth) Protection Input-Output: 2 MOPP Efficiency >87%, typical Isolation Input-Ground: 1 MOPP Output-Ground: 1 MOPP 20 to 30W continuous – See models chart for Output Power Safety Standards EN/IEC/UL60601-1-1, 3rd edition specific voltage model ratings. No Load Input <0.1W per DoE Efficiency Level VI Operating -20°C to +70°C. See curve for derating Requirements Power Temperature See models chart on pg 1. -40°C to +85°C Ripple and Noise Storage Temperature Operating: to 5000m. Output Voltage See models chart on pg 1. Altitude Non-operating: -500 to 40,000 ft. 500µs response time for return to within 0.5% Transient of final value for any 50% load step over the Relative Humidity 5% to 95%, non-condensing range of 5% to 100% of rated load,∆i/∆t< Response 0.2A/µs. Max. voltage deviation is +/-3.5%. 1.4m from table top to wooden platform, 6 Regulation See models chart on pg 1. Drop Test faces. www.slpower.com ME30 Rev 2.1 9-NOV-17 2 ME30 20 to 30W Single Output External Power Medical Series General Specifications (continued) Parameter Specification Parameter Specification Operating: 0.003g/Hz, 1.5grms overall, 3 Operating: Half-sine, 20gpk, 10mS, 3 axes, axes, 10 min/axis, 1-500Hz. 6 shocks total Non-Oper.: random waveform, 3 minutes per Non-Operating: Half-sine waveform, impact Vibration axis, 3 axes and Sine waveform, Vib. Shock acceleration of 100G, Pulse duration of 6 frequency/acceleration: 10-500Hz/1g, sweep mS, Number of shocks: 3 for each of the rate of 1 octave / minutes, Vibration time of three axis 10 sweeps / axes, 3 axes >1,000,000 hours, full load, 110 & 220Vac Dimensions See outline drawings MTBF input, 25°C amb., per Telcordia 332 Issue 6. >8 year life based on calculations at 115Vac/60Hz & 230Vac/50Hz, ambient Weight 250g E-Cap Life 25°C at 24 hrs per day, 365 days/year, 6 power up cycles per day. All specifications are typical at nominal input, full load, at 25°C ambient unless noted. EMI/EMC Compliance Parameter Specification Conducted Emissions: EN55011/CISPR11 Class B, FCC Part 15.107, Class B: >6db margin typ, at 115 and 230Vac Radiated Emissions: EN55022/CISPR11 Class B, FCC Part 15.109, Class B: >3db margin typ, at 115 and 230Vac Common Mode Noise: High Frequency (100kHz-20MHz): <40mA pk-pk Electro-Static Discharge (ESD) EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A th IEC60601-1-2, 4 Edition, Table 4 Immunity on Power ports: EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz Radiated RF EM Fields Susceptibility th IEC60601-1-2, 4 Edition, Table 4 EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A Electrical Fast Transients (EFT) /Bursts: th IEC60601-1-2, 4 Edition, Table 5 Surges, Line to Line (Diff Mode) and Line EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A th to GND (CMN Mode) Surpasses IEC60601-1-2, 4 Edition requirements. EN55022/IEC61000-4-6, 3.6V/m – Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur Conducted Disturbances induced by RF radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz Fields th IEC60601-1-2, 4 Edition, Table 5. EN55024/IEC1000-4-8, Level 4: 30A/m, 50/60 Hz Rated Power frequency magnetic fields IEC60601-1-2, 4th Edition, Table 4 EN55024/IECEN61000-4-11: --100% dip for 10 mS, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees, 100% dip for 20mS, 0 deg., Criteria A Voltage Interruptions, Dips, Sags & --100% dip for 5000mS (250/300 cycles), Criteria B Surges -- 60% dip for 100mS, Criteria B -- 30% dip for 500mS, Criteria A IEC60601-1-2, 4th Edition, Table 5 Harmonic Current Emissions EN55011/EN61000-3-2, Class A EN61000-3-3 Flicker Test All specifications are typical at nominal input, full load, at 25°C ambient unless noted. Consult factory for information regarding testing for or usage under special environments. Note: Performance criteria are based are defined as following: A – Normal performance during and after the test B – Temporary degradation, self-recoverable C – Temporary degradation, operator intervention required to recover the operation D – Permanent damage www.slpower.com ME30 Rev 2.1 9-NOV-17 3 ME30 20 to 30W Single Output External Power Medical Series Output Power Derating Output power is derated above 40°C as follows, for operation over the entire AC input range (90-264Vac). 35 30 25 20 5V 12V-48V 15 10 5 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 Ambient Temperature ͦC Mechanical Drawing 54 33.6 55 Cable length for 5V and 9V models is 1200 +/- 50mm Cable length for 5V and 9V models is 1200 +/- 50mm IEC60320 C14 Receptacle, 2.5 x 5.5 x 9.5mm Barrel Connector Interchangeable N.A. Blade, 2.5 x 5.5 x 9.5mm barrel connector Notes: 1. All dimensions in mm. 2. Interchangeable blade models come with North American blade fitted. For other blades (EU, UK, Aust.) order blade kit KT1027K. www.slpower.com ME30 Rev 2.1 9-NOV-17 4 95.5 1450±50 Output Power - Watts 96 1450±50 ME30 20 to 30W Single Output External Power Medical Series Connector Information Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. Other standard options are listed below. The “03” in the standard model number is replaced by the applicable digits below: These are the most common standard connectors. SL Power has the capability to incorporate any non-standard output connector. All output connectors are limited by wattage range and application type. The SL Power applications team is available to provide professional support and can be contacted here: info@slpower.com. DataSheet © 2017 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com ME30 Rev 2.1 9-NOV-17 5
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the ME30A0502C01?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers





What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods