SL POWER ME40A1802F01
Specifications
Manufacturer
SL Power
Manufacturers Part #
ME40A1802F01
Brand
Ault
Series
ME40
Factory Pack Quantity
1
Dimensions
3.80 x 2.10 x 1.20"
Mechanical Style
External
Mounting
Desktop
Number of Outputs
1
Operating Temperature
- 20 to + 70°C
Output Amps 1
2.22 A
Output Voltage V1 Nominal
18 VDC
Power
40 W
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
ME40 40W Single Output External Power Medical Series Features * Meets UL/EN/IEC60601-1-2, 4th edition for EMC Approved to EN/IEC/UL60601-1, 3rd edition 2 MOPP Input to Output Isolation Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 40W of AC-DC Power Universal Input 90-264Vac Input Range Desktop and Wall-Plug versions Meets EN55011/CISPR11, FCC Part 15.109 Class B Conducted & Radiated Emissions, with 6db margin IP22 Rated Enclosure E-cap life of >8 years >1,000,000 hours MTBF 3 Year Warranty Description A high performance AC to DC external power supply family designed for medical applications. The ME40A Medical Series low power external AC-DC power supplies are approved to safety EN/IEC/UL60601-1, 3rd edition with isolation levels which satisfy the 2 MOPP * requirements and designed to UL/EN/IEC60601-1-2, 4th edition for EMC . The ME40A Series models will operate at universal input range of 90 to 264Vac over the wide temperature range of -20°C to +70°C, delivering full rated output power up to +40°C and applicable output power derating at 70°C. These models are available in desktop and wall-plug versions, include an IP22 rating per IEC60529 for the enclosure, and output cable terminated at a variety of output connectors. *Consult Factory for Table 9 compliance information. Model Selection Overvoltage Output Input Model Output Output Ripple & Line Load Number Volts Current Power Noise¹ Regulation Regulation Trip Range Connector Configuration ME40A0503F01 5.0V 5.00A 25W 100mV pk-pk 120%-150% ±1% ±5% ME40A0903F01 9.0V 4.00A 36W 100mV pk-pk ±1% ±5% 120%-150% 2.5 x 5.5 x 9.5mm Class I Desktop, ME40A1203F01 12.0V 3.40A 40W 120mV pk-pk ±1% ±5% 120%-150% Straight Barrel Type, IEC60320 C14 center positive Receptacle ME40A1803F01 18.0V 2.22A 40W 180mV pk-pk 120%-150% ±1% ±5% ME40A2403F01 24.0V 1.70A 40W 240mV pk-pk ±1% ±5% 120%-140% ME40A0503N01 5.0V 5.00A 25W 100mV pk-pk ±1% ±5% 120%-150% ME40A0903N01 9.0V 4.00A 36W 100mV pk-pk ±1% ±5% 120%-150% 2.5 x 5.5 x 9.5mm Class II Desktop, ME40A1203N01 12.0V 3.40A 40W 120mV pk-pk ±1% ±5% 120%-150% Straight Barrel Type, IEC60320 C8 center positive Receptacle ME40A1803N01 18.0V 2.22A 40W 180mV pk-pk ±1% ±5% 120%-150% ME40A2403N01 24.0V 1.70A 40W 240mV pk-pk ±1% ±5% 120%-140% ME40A0503Q01 5.0V 5.00A 25W 100mV pk-pk ±1% ±5% 120%-150% ME40A0903Q01 9.0V 4.00A 36W 100mV pk-pk ±1% ±5% 120%-150% 2.5 x 5.5 x 9.5mm Class II Desktop, ME40A1203Q01 12.0V 3.40A 40W 120mV pk-pk 120%-150% Straight Barrel Type, IEC60320 C18 ±1% ±5% center positive Receptacle ME40A1803Q01 18.0V 2.22A 40W 180mV pk-pk 120%-150% ±1% ±5% ME40A2403Q01 24.0V 1.70A 40W 240mV pk-pk 120%-140% ±1% ±5% ME40A0503B01 5.0V 5.00A 25W 100mV pk-pk 120%-150% ±1% ±5% ME40A0903B01 9.0V 4.00A 36W 100mV pk-pk ±1% ±5% 120%-150% Class II Wall-Plug, 2.5 x 5.5 x 9.5mm Interchangeable ME40A1203B01 12.0V 3.40A 40W 120mV pk-pk ±1% ±5% 120%-150% Straight Barrel Type, center positive Blades² ME40A1803B01 18.0V 2.22A 40W 180mV pk-pk ±1% ±5% 120%-150% ME40A2403B01 24.0V 1.70A 40W 240mV pk-pk ±1% ±5% 120%-140% ME40A0503C01 5.0V 5.00A 25W 100mV pk-pk ±1% ±5% 120%-150% ME40A0903C01 9.0V 4.00A 36W 100mV pk-pk ±1% ±5% 120%-150% 2.5 x 5.5 x 9.5mm Class II Wall-Plug, Straight Barrel Type, Fixed North ME40A1203C01 12.0V 3.40A 40W 120mV pk-pk ±1% ±5% 120%-150% center positive American Blades³ ME40A1803C01 18.0V 2.22A 40W 180mV pk-pk ±1% ±5% 120%-150% ME40A2403C01 24.0V 1.70A 40W 240mV pk-pk ±1% ±5% 120%-140% Notes: 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. 2. Standard models are fitted with North American blades. Order blade kit KT-1027K for other blades (EU. UK, Australia) 3. For EU fixed blades, replace “C” in the model number with “M”, for UK blades, replace “C” with “G”, for Australia blades, replace “C” with “H”. 4. All specifications are typical at nominal input, full load, at 25°C ambient unless noted. 5. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE40B1203F01). www.slpower.com ME40 Rev 2.4 15-NOV-16 1 ME40 40W Single Output External Power Medical Series General Specifications AC Input 100-240Vac, ±10%, 47-63Hz, 1∅ Turn On Time Less than 700mS @115Vac, full load Input Current 115Vac: 1.2A, 230Vac: 01.6A Hold-up Time 20mS min., at full Load, 100Vac input Overtemperature Will shutdown upon an over-temperature Inrush Current 264Vac, cold start: will not exceed 40A condition, auto-recovery. Protection F1, F2: 2.0A, 250Vac fuses (line & neutral Input Fuses Overload Protection 130 to 180% of rating, Hiccup Mode lines) provided on all models Earth Leakage Input-GND: <500μA@264Vac, 60Hz, NC Short Circuit Hiccup Mode, auto recovery. Output-GND: <4mA@264Vac, 60Hz, NC Current Protection Overvoltage Hiccup mode. See models chart for trip Efficiency >87%, typical Protection ranges. Input-Output: 2 MOPP 40W continuous – See models chart for Output Power Isolation Input-Ground: 1 MOPP specific voltage model ratings. Output-Ground: 1 MOPP No Load Input <0.1W per DoE Efficiency Level VI Safety Standards EN/IEC/UL60601-1, 3rd edition and Requirements Power Operating Ripple and Noise See models chart on pg 1. -20°C to +70°C Temperature Temperature See models chart on pg 1. See derating chart Output Voltage Derating 500µs response time for return to within 0.5% Transient of final value for any 50% load step over the Storage Temperature -40°C to +85°C Response range of 5% to 100% of rated load,∆i/∆t< 0.2A/µs. Max. voltage deviation is +/-3.5%. Operating: to 5000m. See models chart on pg 1. Regulation Altitude Non-operating: -500 to 40,000 ft. 1.4m from table top to wooden platform, 6 Drop Test Relative Humidity 5% to 95%, non-condensing faces. Operating: 0.003g/Hz, 1.5grms overall, 3 Operating: Half-sine, 20gpk, 10mS, 3 axes, axes, 10 min/axis, 1-500Hz. 6 shocks total Non-Oper.: random waveform, 3 minutes per Non-Operating: Half-sine waveform, impact Vibration axis, 3 axes and Sine waveform, Vib. Shock acceleration of 100G, Pulse duration of 6 frequency/acceleration: 10-500Hz/1g, sweep mS, Number of shocks: 3 for each of the rate of 1 octave / minutes, Vibration time of 10 three axis sweeps / axes, 3 axes >1,000,000 hours, full load, 110 & 220Vac Dimensions See outline drawings MTBF input, 25°C amb., per Telcordia 332 Issue 6. >8 year life based on calculations at 115Vac/60Hz & 230Vac/50Hz, ambient 25°C 250g Weight E-Cap Life at 24 hrs per day, 365 days/year, 6 power up cycles per day. All specifications are typical at nominal input, full load, at 25°C ambient unless noted. www.slpower.com ME40 Rev 2.4 15-NOV-16 2 ME40 40W Single Output External Power Medical Series EMI/EMC Compliance EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac Conducted Emissions: Radiated Emissions: EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac High Frequency (100kHz-20MHz): <40mA pk-pk Common Mode Noise: Electro-Static Discharge (ESD) EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A th IEC60601-1-2, 4 Edition, Table 4 Immunity on Power ports: EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz Radiated RF EM Fields Susceptibility th IEC60601-1-2, 4 Edition, Table 4 EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A Electrical Fast Transients (EFT) /Bursts: th IEC60601-1-2, 4 Edition, Table 5 Surges, Line to Line (Diff Mode) and Line EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A th Surpasses IEC60601-1-2, 4 Edition requirements. to GND (CMN Mode) EN55022/IEC61000-4-6, 3.6V/m – Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur Conducted Disturbances induced by RF radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz Fields th IEC60601-1-2, 4 Edition, Table 5. EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz Rated Power frequency magnetic fields IEC60601-1-2, 4th Edition, Table 4 EN55024/IECEN61000-4-11: --100% dip for 10 mS, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees, 100% dip for 20mS, 0 deg., Criteria A Voltage Interruptions, Dips, Sags & --100% dip for 5000mS (250/300 cycles), Criteria B --60% dip for 100mS, Criteria B Surges --30% dip for 500mS, Criteria A IEC60601-1-2, 4th Edition, Table 5 EN55011/EN61000-3-2, Class A Harmonic Current Emissions Flicker Test EN61000-3-3 All specifications are typical at nominal input, full load, at 25°C ambient unless noted. Consult factory for information regarding testing for or usage under special environments. Mechanical Drawing 54 33.6 55 IEC60320 C14 Receptacle, 2.5 x 5.5 x 9.5mm Barrel Connector Interchangeable N.A. Blade, 2.5 x 5.5 x 9.5mm barrel connector Notes: 1. All dimensions in mm. 2. Interchangeable blade models come with North American blade fitted. For other blades (EU, UK, Aust.) order blade kit KT1027K. www.slpower.com ME40 Rev 2.4 15-NOV-16 3 95.5 1450±50 96 1450±50 ME40 40W Single Output External Power Medical Series Derating Chart: ME40 Series Power Derating 45 40 35 30 25 5V 20 12V 15 18V 10 24V 5 0 -20° -10° 0° 10° 20° 30° 40° 50° 60° 70° Ambient Operating Temperature (°C) Connector Information Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. Other standard options are listed below. The “03” in the standard model number is replaced by the applicable digits below: Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com ME40 Rev 2.4 15-NOV-16 4 Output Power (Watts)
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the ME40A1802F01?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers





What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods