SL POWER ME60A0551F01
Specifications
Manufacturer
SL Power
Manufacturers Part #
ME60A0551F01
Brand
Ault
Series
ME60
Factory Pack Quantity
1
Dimensions
4.25 x 2.67 x 1.29"
Mechanical Style
External
Mounting
Desktop
Number of Outputs
1
Operating Temperature
- 20 to + 70°C
Output Amps 1
7 A
Output Voltage V1 Nominal
5 VDC
Power
35 W
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
ME60 60W Single Output External Power Medical Series Features Meets UL/EN/IEC60601-1-2, 4th edition for * EMC Approved to EN/IEC/UL60601-1, 3rd edition with isolation levels which satisfy the 2 MOPP requirements Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 60W of AC-DC Power Universal Input 90-264Vac Input Range Desktop Style Package Meets EN55011/CISPR11, FCC Part 15.109 Class B Conducted & Radiated Emissions, with 6db margin E-cap life of >7 years 3 Year Warranty IP22 Rated Enclosure Description A high performance AC to DC external power supply family designed for medical applications. The ME60A Medical Series low power external AC-DC power supplies are approved to safety EN/IEC/UL60601-1, 3rd edition and EN/IEC/UL60601-1-11:2010 for Home Healthcare (non-hospital use) applications with and isolation levels which satisfy the 2 MOPP requirements and * designed to UL/EN/IEC60601-1-2, 4th edition for EMC . The ME60A Series models will operate at universal input range of 90 to 264Vac over the wide temperature range of -20°C to +70°C, delivering full rated output power up to +40°C and applicable output power derating at 70°C. These models are available in desktop versions, include an IP22 rating per IEC60529 for the enclosure, and the output cable can be terminated at a variety of output connectors. *Consult Factory for Table 9 compliance information. Model Selection Output Output Input Model Output Output Ripple & Line Load Number Volts Current Power Noise¹ Regulation Regulation Connector Cable Configuration 2 ME60A0551F01 5.0V 7.00A 35W 75mV pk-pk ±1% ±5% 6 pin Molex Type 1150mm, #18AWG ME60A0903F01 9.0V 6.00A 56W 90mV pk-pk ±1% ±5% ME60A1203F01 12.0V 5.00A 60W 120mV pk-pk ±1% ±5% Class I Desktop, 2.5 x 5.5 x 9.5mm 9V:1150mm ME60A1503F01 15.0V 4.00A 60W 150mV pk-pk ±1% ±5% IEC60320 C14 Straight Barrel 18AWG Receptacle Type, center All others: ME60A1803F01 18.0V 3.30A 60W 180mV pk-pk ±1% ±5% positive 1500mm, #18AWG ME60A2403F01 24.0V 2.70A 60W 240mV pk-pk ±1% ±5% ME60A4803F01 48.0V 1.35A 60W 480mV pk-pk ±1% ±5% 3 ME60A0551N01 5.0V 7.00A 35W 75mV pk-pk ±1% ±5% 6 pin Molex Type 1150mm, #18AWG ME60A0903N01 9.0V 6.00A 56W 90mV pk-pk ±1% ±5% ME60A1203N01 12.0V 5.00A 60W 120mV pk-pk ±1% ±5% Class II Desktop, 2.5 x 5.5 x 9.5mm 9V:1150mm ME60A1503N01 15.0V 4.00A 60W 150mV pk-pk IEC60320 C8 ±1% ±5% Straight Barrel 18AWG Receptacle Type, center All others: ME60A1803N01 18.0V 3.30A 60W 180mV pk-pk ±1% ±5% positive 1500mm, #18AWG ME60A2403N01 24.0V 2.70A 60W 240mV pk-pk ±1% ±5% ME60A4803N01 48.0V 1.35A 60W 480mV pk-pk ±1% ±5% 3 ME60A0551Q01 5.0V 7.00A 35W 75mV pk-pk ±1% ±5% 6 pin Molex Type 1150mm, #18AWG ME60A0903Q01 9.0V 6.00A 56W 90mV pk-pk ±1% ±5% ME60A1203Q01 12.0V 5.00A 60W 120mV pk-pk ±1% ±5% Class II Desktop, 2.5 x 5.5 x 9.5mm 9V:1150mm ME60A1503Q01 15.0V 4.00A 60W 150mV pk-pk ±1% ±5% IEC60320 C18 Straight Barrel 18AWG Receptacle Type, center All others: ME60A1803Q01 18.0V 3.30A 60W 180mV pk-pk ±1% ±5% positive 1500mm, #18AWG ME60A2403Q01 24.0V 2.70A 60W 240mV pk-pk ±1% ±5% ME60A4803Q01 48.0V 1.35A 60W 480mV pk-pk ±1% ±5% Notes: 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. For 5V models, values listed are typical, 100mV pk-pk maximum. 2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information. 3. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE60B1203F01). 4. All specifications are typical at nominal input, full load, at 25°C ambient unless noted. www.slpower.com ME60 Rev 2.9 9-NOV-17 1 ME60 60W Single Output External Power Medical Series General Specifications Parameter Specification Parameter Specification Less than 1 sec @115Vac, full load AC Input 100-240Vac, ±10%, 47-63Hz, 1∅ Turn On Time Input Current 100Vac: 1.5A, 240Vac: 0.7A Hold-up Time 20mS min., at full Load, 100Vac input Overtemperature Will shutdown upon an overtemperature Inrush Current 264Vac, cold start: will not exceed 40A condition, auto-recovery. Protection F1, F2: 2A, 250Vac fuses (line & neutral lines) 130 to 180% of rating, Hiccup Mode Input Fuses Overload Protection provided on all models Earth Leakage <500μA@264Vac, 60Hz, NC Short Circuit Hiccup Mode, auto recovery. Current (Input to Ground) <1mA@264Vac, 60Hz, SFC Protection Patient Leakage <100μA@264Vac, 60Hz, NC Overvoltage 130 to 150% of output voltage (max. 60V on <500µA@264Vac, 60Hz, SFC 48V model), hiccup mode Current (Output to Earth) Protection Input-Output: 2 MOPP >88%, typical Input-Ground: 1 MOPP Efficiency Isolation Output-Ground: 1 MOPP 60W continuous – See models chart for Output Power Safety Standards EN/IEC/UL60601-1, 3rd edition specific voltage model ratings. No Load Input <0.210W (meets DoE Efficiency Level VI Operating -20°C to +70°C. See curve for derating. Requirements) Power Temperature Ripple and Noise See models chart on pg 1. Storage Temperature -40°C to +85°C Operating: to 5000m. Output Voltage See models chart on pg 1. Altitude Non-operating: -500 to 40,000 ft. 500µs response time for return to within 0.5% Transient of final value for any 50% load step over the Relative Humidity 5% to 95%, non-condensing Response range of 5% to 100% of rated load,∆i/∆t< 0.2A/µs. Max. voltage deviation is +/-3.5%. 1.4m from table top to wooden platform, 4 See models chart on pg 1. Regulation Drop Test faces. Operating: 0.003g/Hz, 1.5grms overall, 3 Operating: Half-sine, 20gpk, 10mS, 3 axes, axes, 10 min/axis, 1-500Hz. 6 shocks total Non-Oper.: random waveform, 3 minutes per Non-Operating: Half-sine waveform, impact Vibration axis, 3 axes and Sine waveform, Vib. Shock acceleration of 100G, Pulse duration of 6 frequency/acceleration: 10-500Hz/1g, sweep mS, Number of shocks: 3 for each of the rate of 1 octave / minutes, Vibration time of 10 three axis sweeps / axes, 3 axes W: 2.67” x L: 4.25” x H: 1.29” >250,000 hours, full load, 110 & 220Vac Dimensions MTBF W: 67.9mm x L: 108mm x H: 32.7mm input, 25°C amb., per Telcordia 332 Issue 6. >7 year life based on calculations at 115Vac/60Hz & 230Vac/50Hz, ambient 25°C 400g Weight E-Cap Life at 24 hrs per day, 365 days/year, 6 power up cycles per day. (80% load on 5V, 12V model) All specifications are typical at nominal input, full load, at 25°C ambient unless noted. www.slpower.com ME60 Rev 2.9 9-NOV-17 2 ME60 60W Single Output External Power Medical Series EMI/EMC Compliance Parameter Specification EN55011/CISPR11 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac Conducted Emissions: Radiated Emissions: EN55011/CISPR11 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac High Frequency (100kHz-20MHz): <40mA pk-pk Common Mode Noise: Electro-Static Discharge (ESD) EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A th IEC60601-1-2, 4 Edition, Table 4 Immunity on Power ports: EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz Radiated RF EM Fields Susceptibility th IEC60601-1-2, 4 Edition, Table 4 EN55024/IEC61000-4-4, Level 4, +/- 4.4kV, 100Khz rep rate, 40A, Criteria A Electrical Fast Transients (EFT) /Bursts: th IEC60601-1-2, 4 Edition, Table 5 Surges, Line to Line (Diff Mode) and Line EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A th Surpasses IEC60601-1-2, 4 Edition requirements. to GND (CMN Mode) EN55022/IEC61000-4-6, 3.6V/m – Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur Conducted Disturbances induced by RF radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz Fields th IEC60601-1-2, 4 Edition, Table 5 EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz Rated Power frequency magnetic fields IEC60601-1-2, 4th Edition, Table 4 EN55024/IECEN61000-4-11: --100% dip for 10 mS, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees, 100% dip for 20mS, 0 deg., Criteria A Voltage Interruptions, Dips, Sags & --100% dip for 5000mS (250/300 cycles), Criteria B --60% dip for 100mS, Criteria B Surges --30% dip for 500mS, Criteria A IEC60601-1-2, 4th Edition, Table 5 Harmonic Current Emissions EN55011/EN61000-3-2, Class A EN61000-3-3 Flicker Test All specifications are typical at nominal input, full load, at 25°C ambient unless noted. Consult factory for information regarding testing for or usage under special environments. Mechanical Drawing See Note 3: 9V through 48V Models: 2.5 x 5.5 x 9.5mm 5V Models: Output Connector: 6 pin Molex 39-01-2060 Barrel Connector, center positive² or equiv. Pins 1, 4 = (+), pins 3, 6 = (-), pins 2, 5 = NC² Notes: 1) All dimensions in mm. 2) Other options are available. 3) Cable length on 12V through 48V models is 1500mm, nominal. 4) The unit should not be covered or enclosed to protect against excessive case temperature rise. www.slpower.com ME60 Rev 2.9 9-NOV-17 3 ME60 60W Single Output External Power Medical Series Derating Chart: 70 60 50 40 12V 18V 30 24V 20 48V 10 0 -20 -10 0 10 20 30 40 50 60 70 Ambient Temperature- ͦC Connector Information Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive (6-pin Molex type - #51 – on 5V models). Other standard options are listed below. The “03” in the standard model number is replaced by the applicable digits below: These are the most common standard connectors. SL Power has the capability to incorporate any non-standard output connector. All output connectors are limited by wattage range and application type. The SL Power applications team is available to provide professional support and can be contacted here: info@slpower.com. Data Sheet © 2017 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com ME60 Rev 2.9 9-NOV-17 4 Output Power- Watts
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the ME60A0551F01?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers





What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods