SL POWER MINT1500A5614E01
Specifications
Manufacturer
SL Power
Manufacturers Part #
MINT1500A5614E01
Brand
Condor
Series
MINT1500
Factory Pack Quantity
1
Application
General Purpose
Connection Type
Molex/JST
Convection Rating
350 W
Cooling Method
Air-Cooled, Convection
Dimensions
7.00 x 3.30 x 1.50"
Efficiency
92%
Environmental Conditions
General Purpose
Industry
Medical
Input Type
AC
Mechanical Style
Open / Enclosed Frame
Number of Outputs
1
Operating Temperature
0 to +70°C, derate linearly to 50% power from 50-70°C
Output Amps 1
6.3 A
Output Voltage V1 Nominal
56 V
Package Type
Open Frame
Power
500 W
Protection Level
2xMOPP
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
MINT1500 SL POWER 500W Single Output MINT1500 SERIES Medical & ITE Series 500 Watt Medical Power Supply Measures: 7.00 x 3.30 x 1.50” Features 3.3” x 7” x 1.5” Package, Ideal for 1U Applications Up to 500W w/air, 350W convection cooled Universal Input 90 to 270Vac Active current share Class I Input Standby and Fan Output Voltages Inhibit, Power Fail, Output OK Signals rd Approved to IEC60601-1, 3 Edition nd Edition & EN60950 2 2 x MOPP Isolation 93% Efficiency @ 230V Input, 92% @ 115V Input Optional Cover 3 mounting orientations 3 Year Warranty Low inrush Current Description A superior performance 500 Watt AC to DC power supply designed for Medical or Industrial applications. Feature rich and highly efficient, MINT1500 product family with active current share for redundant applications can easily fit in 1U or 2U chassis and provides 350 Watts without cover for convection, or 500 Watts with moving air. Input & output monitoring alarms plus 12V/0.8A fan output and 5V standby voltage are standard features of the MINT1500 family. All models are CE rd nd marked to low voltage directive and approved to IEC60601-1 3 edition, EN60950 2 edition. Model Selection Model Output Current Fan 5V Standby Ripple & Total OVP Number Volts w/200LFM air Convection Output Output Noise¹ Regulation Threshold MINT1500A2414E01 24V 20.8A 14.6A 12Vdc/0.8A 5V@200mA 1% ±2% 27.6 ± 1.0V MINT1500A4814E01 48V 10.4A 7.3A 12Vdc/0.8A 5V@200mA 1% ±2% 55.5 ± 2.0V MINT1500A5614E01 56V 8.9A 6.3A 12Vdc/0.8A 5V@200mA 1% 64.3 ± 2.0V ±2% Notes: 1) Measured with noise probe directly across output terminals with 0.1F ceramic and 10F low ESR capacitors. For main output load of less than 5%, total noise & ripple will increase to 2%. www.slpower.com MINT1500 REV 6.0, 12-18-14 1 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/sl-power-MINT1500-power-supply.html http://power.sager.com SL POWER MINT1500 MINT1500 SERIES 500W 500 W Sing att Medical P le Output ower Supply Medical & ITE Series Measures: 7.00 x 3.30 x 1.50” General Specifications 90-270Vac, 47-63Hz agency approved from 90Vac to 264Vac AC Input 120–300Vdc (External fuse required for DC input) Turn On Time <500mS @115Vac Power supply is protected against brown out condition 115Vac: 5A, 230Vac: 2.5A 20 mS minimum at full load & 100 Vac input Input Current Hold-up Time Power Factor Meets EN61000-3-2, Class A, and D 270Vac, cold start: will not exceed 15A Inrush Current Meets Class C for 500 Watt output Correction Overload F1, F2: T10A, 250Vac, provided on all models 120% to 140% of current rating, Hiccup Mode Input Fuses Protection Main Output Earth Leakage Short Circuit <275A@264Vac, 60Hz, NC; <450μA SFC Self-recovering Current Protection Overvoltage Hiccup Mode, Self-recovering see models chart Efficiency 92% typical at 115Vac, 93% typical at 230Vac for trip ranges. Protection 500W continuous with 200 lfm airflow, up to Overtemperature Provided, self-recovering 350W convection cooled @ 100Vac, 50°C Output Power Automatic power shutdown at TC 135°C/115°C Protection ambient. 500 uS typical for return to within 0.5% of PFC: Variable, 50-500kHz Transient nominal, 50% load step from 5% to 100%. Switching Main Converter: Variable 40-180 kHz, 65Khz Response Δi/Δt: <0.2A/S. F re quency typical Maximum Voltage Deviation = 3% Input-Output: 4000Vac, 2 x MOPP Ripple and Noise See models chart Input-Ground: 1800Vac, 1 x MOPP Isolation Main Output Output-Ground: 700Vdc Operating -10°C to +70°C (Derate output power linearly by 2.5% /˚C See models chart Output Voltage above 50°C to 50% at 70°C) Temperature Voltage Storage +/-5% from nominal -40°C to +85°C Adjustability Temperature Operating: Up to 3000m (derate 5˚C for natural Not required Convection Cooling Applications) Minimum Load Altitude Non-operating: -150 to 12,000m Main Output: ±2%. Relative 12V Fan Output: ±10% (with >0.1A load on main o/p) 5% to 95%, non-condensing Total Regulation Humidity 5Vsb Output: ±2% Operating: 0.003g²/Hz, 1.5grms overall, 3 axes, Operating: Half-sine, 40gpk, 8ms, 3 axes, 6 1 hr/axis Vibration Shock shocks total Operating: 0.026g²/Hz, 5.0grms overall, 3 axes, 10 min/axis W: 3.3” x L: 7.0” x H: 1.5” W: 84mm x L: 178mm x H: 38mm rd EN/CSA/UL/IEC 60601-1, 3 Edition Dimensions Safety Standards With Fan Option: Top Mount: 3.3” x 7.0” x 2.09” With IEC: 3.3” x 8.15” x 1.58” Over 500,000 hours, 25°C Ambient, 115Vac Weight 680g. 750g w/cover MTBF input Single wire current share for up to 3 units. Replace Letter “A” to “C” for this option Please consult Application notes for proper Cover Option Current Share Example: MINT1500C2414E01 wiring www.slpower.com MINT1500 REV 6.0, 12-18-14 2 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/sl-power-MINT1500-power-supply.html http://power.sager.com MINT1500 500W Single Output Medical & ITE Series SL POWER MINT1500 SERIES 500 Watt Medical Power Supply Measures: 7.00 x 3.30 x 1.50” Auxiliary Signals Signal goes HIGH 100-250mS after main During normal operation, this signal is logic output is in regulation, and goes LOW with DC OK: HIGH. Signal will go LOW for output less than 7ms warning time before loss of main output Power Good: 90% of nominal. due to loss of AC input (Output is measured above 90% nominal voltage) Logic High or Open = On Inhibit: Low/ground = Off Current Sharing Active single wire, for up to 3 units in parallel Low or Open = ON PS Off: Logic High = OFF EMI/EMC Compliance Conducted Emissions EN55011/22 Class B, FCC Part 15, Subpart B, Class B Radiated Emissions EN55011/22 Class A; FCC Part 15, Subpart A, Class A EN61000-4-2, Criteria A, 6kV Contact Discharge, 8kV air discharge Static Discharge Immunity EN61000-4-3, 3V/m;10V/M Criteria A, B Radiated RF Immunity EFT/Burst Immunity EN61000-4-4, 2kV/5kHz EN61000-4-5, 1kV differential, 2kV common-mode Line Surge Immunity Conducted RF Immunity EN61000-4-6, 3Vrms EN61000-4-8, 3A/m Power Frequency Magnetic Field Immunity EN61000-4-11, 0% Vin, 10mS; 40% Vin, 100mS (60% load); 70% Vin, Voltage Dip Immunity 500mS (80% load); 0% 5000mS; Criteria A, A, A, B. EN61000-3-2, Class A, and D Line Harmonic Emissions Meets Class C for 500 Watt output Flicker Test EN61000-3-3, Complies Isolation Specifications Parameter Conditions/Description Min Nom Max Units Input/Ground 1 MOPP Insulation Safety Rating Input/Output 2 MOPP Output/Ground Operational Input/Ground 1800 Vac Electric Strength Test Voltage Input/Output 4000 - - Vac Output/Ground 700 Vdc www.slpower.com MINT1500 REV 6.0, 12-18-14 3 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/sl-power-MINT1500-power-supply.html http://power.sager.com MINT1500 500W Single Output Medical & ITE Series SL POWER MINT1500 SERIES 500 Watt Medical Power Supply Measures: 7.00 x 3.30 x 1.50” Mechanical Drawings www.slpower.com MINT1500 REV 6.0, 12-18-14 4 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/sl-power-MINT1500-power-supply.html http://power.sager.com MINT1500 500W Single Output Medical & ITE Series SL POWER MINT1500 SERIES 500 Watt Medical Power Supply Measures: 7.00 x 3.30 x 1.50” Connector Information Input Connector DC Output Fan Output Connector Signal ConnectorJ2 J1 (E Version)) Connector J301 (see Detail B on prior page) PIN 1) GROUND (2) Buss Bars (M5 PIN 1) +12Vfan PIN 1) Remote Sense + PIN 6) Power_Good PIN 3) AC NEUTRAL x 0.5 Screws): PIN 2) RTN PIN 2) Remote Sense – PIN 7) Current Share PIN 5) AC LINE 1) +Vout PIN 3) +5Vsb RTN PIN 8) PS_Off 2) RTN PIN 4) RTN PIN 9) Enable PIN 5) +5Vsb PIN 10) DC_OK Mating Connector: Mating Connector: Mating Connector: Mating Connector: AMP 770849-5 or 647402-5 #M3 Spade or AMP 1375820-2, 3-640441-2, or Molex 90142-0010 Pins= 3-770522-1 or 3-647409-1 Ring Lugs Molex 22-01-3027 Pins = 90119-2109 or 2120 Pins = AMP 1375819-1 or Molex 08- 50-0114 Fan Options Consult Factory Characteristic Curves Output vs. Temperature 350W convection cooled and 500W continuous with 200 LFM airflow. Derate output power to 50% at 70°C. Output Power vs. Ambient Temperature 600 500 400 300 200 100 0 -10 0 10 20 30 40 50 60 70 Ambient Operating Temperature (C) Convection 200LFM Cooling www.slpower.com MINT1500 REV 6.0, 12-18-14 5 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/sl-power-MINT1500-power-supply.html http://power.sager.com Output Power (Watts) MINT1500 500W Single Output Medical & ITE Series SL POWER MINT1500 SERIES 500 Watt Medical Power Supply Measures: 7.00 x 3.30 x 1.50” Power_Good, DC_OK, Inhibit Signals and Current Sharing – J2 1. Power_Good: - Output Signal – J2 Pin 6 During normal operation is Logic High, goes HIGH 100-250 ms after main output is in regulation, and goes LOW with 7ms warning time before loss of main output due to loss of AC input. Note: Power_Good signal is a combination of AC OK (Internal) and DC_OK such that failure of either one will cause the Power_Good signal to go low. Logic High: >4.5V sourcing 16mA Logic Low: <0.5V sinking 16mA Figure 1 2. DC_OK: Output signal – J2 Pin 10 During normal operation, this signal is logic High. It will go logic Low for output less than 90% of its nominal rated voltage. Logic High: >4.5V sourcing 16mA Logic Low: <0.5V sinking 16mA Figure 2 3. Enable: Input signal – J2 Pin 9 Logic High or Open = ON Low/ground = OFF Logic High >3.4V Logic Low <1.2V Internal pull up resistor: 43KΩ to 5V 4. PS_Off: Input signal – J2 Pin 8 Logic Low or Open = ON Logic High = OFF Logic High >3.4V Logic Low <1.2V www.slpower.com MINT1500 REV 6.0, 12-18-14 6 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/sl-power-MINT1500-power-supply.html http://power.sager.com SL POWER MINT1500 MINT1500 SERIES 500W 500 W Sing att Medical P le Output ower Supply Medical & ITE Series Measures: 7.00 x 3.30 x 1.50” Internal pull down resistor: 43KΩ to V-. 5. Remote Sense Output Signal – J2 Pin 1 (+Sense), J2 Pin 2 (-Sense) Less than 250mV voltage drop compensation due to cable loss on each side of main output. See Figure 3 for wiring connection. 6. Stand-By Output – J2 Pin5 (+), J2 Pin 4 (–) The standby output is always available when AC input is present. It is rated for 5V/0.2A. Data Sheet © 2014 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com MINT1500 REV 6.0, 12-18-14 7 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/sl-power-MINT1500-power-supply.html http://power.sager.com
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the MINT1500A5614E01?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers





What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods