SL POWER MU425S12E
Specifications
Manufacturer
SL Power
Manufacturers Part #
MU425S12E
Brand
Condor
Series
MU425S
Factory Pack Quantity
1
Cooling Method
Air-Cooled, Convection
Dimensions
6.20 x 3.30 x 1.62"
Efficiency
88%
Mechanical Style
Open / Enclosed Frame
Mounting
Chassis
Number of Outputs
1
Operating Temperature
- 10 to + 70°C
Output Amps 1
32.2 A
Output Voltage V1 Nominal
12 VDC
Power
425 W
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
MU425S 425W Single Output Medical Power Supply Features 3.3” x 6.2” x 1.62” Package Up to 425W of Air-Cooled Power, 300W Convection Universal Input 90-264Vac Input Range 5V at 2A Standby Output 12V Fan Output Inhibit, Power Fail, DC OK Signals, Remote Sense rd Approved to CSA/EN/IEC/UL60601-1, 3 Edition 2 MOPP Isolation Meets EN61000-4-2, EN61000-4-3 and EN61000-4-6 Requirements for Home Healthcare Applications Efficiency 88% typical 3-Year Warranty RoHS Compliant Description The MU425 family is designed to power the latest professional healthcare devices. All models meet 2 MOPP input-to-output isolation. Models are available with main output voltages of 12V, 18V, 24V and 48V. Model Selection 4 Model Output Current Ripple & Noise³ Total Efficiency OVP (Main Output) Number Volts w/200LFM air¹ Convection² Regulation Threshold (mV pk-pk) 88% 12V 32.2A 22.0A 120mV ±3% 14.0± 1.1V MU425S12E 5Vsb 2.0A 2.0A 100mV ±5% 5.5V – 8.0V 6 5 12V Fan 1.0A 0.5A 360mV ±10% N/A 88% 18V 21.45A 14.6A 180mV ±3% 21.0± 2.0V MU425S18E 5Vsb 2.0A 2.0A 100mV ±5% 5.5V – 8.0V 6 5 12V Fan 1.0A 0.5A 360mV ±10% N/A ±3% 90% 24V 16.8A 11.9A 240mV 28.0± 2.5V MU425S24E 5Vsb 2.0A 2.0A 100mV ±5% 5.5V – 8.0V 6 5 12V Fan 1.0A 0.5A 360mV N/A ±10% ±3% 90% 48V 8.4A 5.9A 480mV 58.0± 2.0V MU425S48E 5Vsb 2.0A 2.0A 100mV ±5% 5.5V – 8.0V 6 5 12V Fan 1.0A 0.5A 360mV N/A ±10% Notes: 1. Total power with 200 lfm of forced air cooling is 425W (408W for 18V, 385W for 12V) including 12V/1A for Fan output and 5V/2A standby. 2. Total convection power is 300W (280W for 12V model). Total power includes 5Vsb and Fan outputs. 3. Measured at 25°C ambient with noise probe directly at end of 6” twisted pair terminated with 0.1μF ceramic and 10μF low ESR capacitors. Values will be higher at ambient temperatures below 0°C. 4. Efficiency values listed are typical and are measured at 115Vac input, full load output current, at an ambient temperature of 25°C. 5. Fan output regulation is with 1A min load on main output. 6. Fan Output: If the load on the output is other than a fan, a short circuit condition on the output can only be remedied by removing both the cause of the short circuit and the load. This will allow the output to resume normal operation. General Specifications Main output: <1 sec. max @115Vac, rise time 30mS max. Turn On Time 100-240Vac, ±10%, 47-63Hz, 1∅ 5Vsb turn-on time is 500mS max., rise time 50mS max. AC Input 120–300Vdc (external fuse required for DC input) (Main Output) Output Voltage rise is monotonic. Main Output: >20ms for 300W @ 120Vac/60 Hz, >16ms Input Current 115Vac: 5.2A, 230Vac: 2.5A Hold-up Time for 367W (90% of 408W) @ 120v/60Hz. 5Vsb Output: >500mS 264Vac, cold start: will not exceed 40Arms Overtemperature Sensing transformer temperature, 135°C (55°C ambient Inrush Current within ½ cycle. I²T = 25A²/Sec maximum temperature at full load), auto recovery. Protection Overload Input Fuses F1, F2: 6.3A, 250Vac 130 to 170% of rating, Hiccup Mode, auto-recovery. Protection Switching Efficiency See chart above. 75kHz, typical Frequency www.slpower.com MU425S REV 3.1 14-APR-16 1 MU425S 425W Single Output Medical Power Supply General Specifications (continued) Earth: <750μA@264Vac, 60Hz, NC Main Output & 5Vsb: Cycling type, auto recovery. Leakage <1.5mA@264Vac, SFC Short Circuit Fan Output: Recovery only after removal of short and Touch: <100uA @264Vac, NC Current Protection load. See note 5 above. <500uA @264Vac, SFC >0.99 @ 115Vac, Full Load Overvoltage OVP latch, see chart for trip ranges. Power Factor >0.95 @ 230Vac, Full Load 5V standby output (latch), see chart for trip range. Protection 425W continuous (24V model), with 200 lfm Input-Output: 2 MOPP airflow. 408W for 18V, 385W for 12V models. Input-Ground: 1 MOPP Output Power Isolation 300W convection cooled (280W for 12V model) Output-Ground: 1500Vdc 50% load step,∆i/∆t: <0.2A/μS. Max Voltage Operating -10 to 70°C. Starts up- 40°C. The unit will meet all Transient Response Deviation = 5%. Recover to within 1% of published specifications after a warm-up period Temperature nominal within 500µS Temperature 0.5%rms, 1% pk-pk, see chart on page 1. Derate output power linearly above 50°C to 50% at 70°C Ripple and Noise Derating Line Frequency: <2.5Vrms @115Vac, <5Vrms@ Common Mode 230Vac, 50/60Hz. For high frequency noise Storage -40°C to +85°C and/or test set-up information, consult SL Noise Temperature Power. Operating: up to 5000m (derating may be required See chart on page 1. Initial setpoint within 0.5% Output Voltage Altitude above 3000m, consult factory) of nominal. Adjustable +/-5% from nominal. Non-operating: -500 to 40,000 ft. Not required for main output or 5Vsb. 12V Fan Minimum Load output requires minimum load of 0.5A on main Relative Humidity 5% to 95%, non-condensing output in order to be within its regulation band Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks total. See chart on page 1. Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks Total Regulation Shock total Operating: 0.003g/Hz, 1.5grms overall, 3 axes, rd Vibration 10 min/axis. Non-Operating: 0.026g2/Hz, Safety Standards EN/CSA/UL/IEC 60601-1, 3 Edition 5.0grms overall, 3 axes, 1 hr/axis W: 3.3” x L: 6.2” x H: 1.62” 356,330 hours, per Telcordia 332, Issue 6, 25°C, full rated Dimensions MTBF W: 84mm x L: 157.5mm x H: 41mm load (w/airflow) at 110Vac input. 7 years, based on typical operation of 12 hours/day, 261 670g Weight E-Cap Life days/year at 40°C ambient temp. Auxiliary Signals Signal is HIGH within 500mS after the main output is within regulation band upon AC turn Goes HIGH when main DC output is above 90% of nominal Power Good/ on. Goes LOW within 4mS min. before the DC OK: voltage and goes LOW when the output is below 90% of Power Fail: main DC output drops to <90% of nominal rated main output DC voltage when AC turns off. 12V@1A (air cooled ) or 0.5A (convection), 5V @ 2A, +/-5% regulation over all changes in 5V Standby Output: Fan Output: +/-10% regulation for load change of 0.5A to FL on the main output load current. main output. Compensates for up to 0.16V voltage drop. Logic HIGH or open = ON Remote Sense: Max. deviation of 5% (main output) any 50% Inhibit: Logic LOW or short to ground = OFF step above 5% load Connector Information Input Connector Main DC Output Fan Output Signal Connector J101 J302, J303 J301 J401 PIN 1) FG PIN 4) NC Term 1 – J302: (+V) PIN 1) 12V Fan (+) PIN 1) Remote Sense (+) PIN 5) Remote Inhibit PIN 8) +5Vsb Output Term 2 – J303: (─V) PIN 2) 12V Fan (─) PIN 2) NC PIN 5) AC Line PIN 2) Common PIN 6) Power Good PIN 9) DC OK PIN 3) AC Neutral PIN 3) Remote Sense (─) PIN 7) +5Vsb Output PIN 10) Common PIN 4) NC Mating Connector: Mating Connector: Mating Connector: Mating Connector: Tyco/AMP 640250-5 Molex 19141-0058 Tyco AMP Molex 90142-0010 Pins: 770476-1 19141-0063 1375820-2 Pins: 90119-2110 19141-0083 Pins: 1375819 www.slpower.com MU425S REV 3.1 14-APR-16 2 MU425S 425W Single Output Medical Power Supply EMI/EMC Compliance EN55011/CISPR22 Class B, FCC Part 15.107, Class B, 6db margin, typical. Conducted Emissions EN55022/CISPR22 Class A, FCC Part 15.109, Class A, 3db margin, typical. Radiated Emissions EN55024/IEC61000-4-2, Level 4, 8kV Contact Discharge, 15kV air discharge, Criteria A Static Discharge Immunity Radiated RF Immunity EN55022/IEC61000-4-3, Level 2, 10V/m, 80-2,700 MHz Criteria A EFT/Burst Immunity EN55024/IEC61000-4-4, Level 3, 2kV (PS Output), 1kV (signal outputs), Criteria A 100Khz Line Surge Immunity EN55024/IEC61000-4-5, Level 3, 1kV diff., 2kV common-mode, Criteria A Conducted RF Immunity EN55022/IEC61000-4-6, Level 3, 3Vrms,0.15-80Mhz and 6V@ISM frequency Criteria A EN55024/IEC61000-4-8, Level 3, 30A/m, Criteria A Power Frequency Magnetic Field Immunity EN55024/IEC61000-4-11, Dips: 100%, 10mS, 8 phase angles ; 100%, 20ms; 30%, 500mS; Voltage Dip Immunity Interruptions: 100%, 5000mS; Performance Criteria A, A (300W), A &B. Line Harmonic Emissions EN55024/IEC61000-3-2, Class A & D at full load Flicker Test EN55024/IEC61000-3-3, Section 5; 50Hz Mechanical Drawing Notes: 1. All dimensions in mm (inches), tolerance is ±0.2mm. 3. FG is safety ground connection 4. Specifications are for convection rating at factory settings at 115Vac input 25°C unless otherwise stated. Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com MU425S REV 3.1 14-APR-16 3
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the MU425S12E?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers





What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods