SL POWER PW174KB1503F01
Specifications
Manufacturer
SL Power
Manufacturers Part #
PW174KB1503F01
Selling Alternatives
PW174KB1203F01, PW174KB1803F01
Brand
Ault
Series
PW174KB
Factory Pack Quantity
1
Dimensions
4.25 x 2.68 x 1.57"
Input Type
Universal
Isolation
3000 VAC
Mechanical Style
External
Mounting
Desktop
Number of Outputs
1
Operating Temperature
0 to + 40°C
Output Amps 1
4 A
Output Voltage V1 Nominal
15 VDC
Package Type
Enclosed
Power
60 W
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
APPLICATION NOTE Energy Efficiency Requirements by Levels VI AN-G-001/15 AMERICAS | EUROPE | ASIA APPLICATION NOTE Energy Efficiency Requirements by Levels As early as 1992, the U.S. Environmental Protection Agency started a voluntary program to promote energy efficiency and reduce pollution, which eventually became the Energy Star program. However, it was not until 2004 that the first mandatory regulations dictating average efficiency minimums and no-load power consumption maximums were put into place. As different countries enacted stricter requirements and moved from voluntary to mandatory programs, the Energy Star program defined the International Efficiency Marking Protocol to minimize confusion between regions and their similar standards. The defined markings set minimum average efficiency and maximum no-load power consumption levels for external power supplies: n Level I: Power supply does not meet any of the standards defined. n Level II: Power supply meets minimum efficiencies that were required by China in November 2005. n Level III: Power supply meets Energy Star Tier 1, CEC Tier 1, and Australian MEPS standards. n Level IV: Power supply meets EISA 2007, CEC Tier 2, and the Australian MEPS High Efficiency category. n Level V: Power supply meets CEC Tier 3 and EU phase 2 standards. n Level VI: Power supply meets DOE new standards effective in the US on February 10, 2016. Table I below shows the countries or regions mandating that all external power supplies (EPS) shipped across their borders meet the specified efficiency level (prior to 2/10/2016): LEVEL COUNTRY IV United States IV Canada V European Union TABLE I. Efficiency Level Requirements Level VI Requirement: The new DOE Level VI efficiency standard mandates that No-Load power consumption does not exceed 0.100 W for EPS ranging from <1 W to ≤ 49 W and does not exceed 0.210W for EPS >49W to ≤250W. It boosts the mandatory average efficiency by about 1%, and has set standards for EPS with power ratings above 250 W for the first time. The new regulations apply to all direct and indirect operation EPS. The regulations also extend their scope to encompass lower voltage DC-output EPS, multiple-output voltage EPS, and EPS with nameplate output power ratings exceeding 250 watts. The compliance date for the new requirements is February 10, 2016. AN-G-001/15 | Page 2 I SL Power Electronics I I SL Power Electronics I APPLICATION NOTE The nameplate of single voltage AC-DC EPS are marked with a Roman numeral from the sequence I (least efficient) to VI (most efficient) that corresponds to specific minimum Active average efficiency and No-Load power levels. The performance requirements for each Roman numeral are shown in Table II below. Performance Requirements* – Single-Output EPS Level Nameplate Minimum Average Efficiency in Active Maximum Output Power Mode Power in No- Power Factor (Pno) (expressed as a decimal) Load Mode (W) Used if none of the other criteria are met I <1 watt ≥0.39xPno ≤0.75 1 to ≤10 watts ≥0.107 x Ln(Pno) + 0.39 Not Applicable II >10 to 49 watts ≥0.107 x Ln(Pno) + 0.39 ≤1.0 >49 watts ≥0.82 ≤1 watt ≥0.49xPno ≤0.5 >1 to <10 watts ≥0.09 x Ln(Pno) + 0.49 Not Applicable III 10 to 49 watts ≥0.09 x Ln(Pno) + 0.49 ≤0.75 >49 to 250 watts ≥0.84 <1 watt ≥0.5xPno 1 to 51 watts ≥0.09 x Ln(Pno) + 0.50 ≤0.5 Not Applicable IV >51 to 250 watts ≥0.85 1 Basic Voltage : ≥0.480 x Pno + 0.140 ≤1 watt 2 Low Voltage : ≥0.497 x Pno + 0.067 ≥0.9 at 115Vac/60Hz 1 ≤0.3 Basic Voltage : ≥0.0626 x Ln(Pno) + for power 0.622 >1 to ≤49 watts V supply with 2 Low Voltage : ≥0.0750 x Ln(Pno) + 0.561 input power 1 Basic Voltage : ≥0.870 ≥100 watts ≥50 to ≤250 watts ≤0.5 2 Low Voltage : ≥0.860 1 Basic Voltage : ≥0.5 x Pno + 0.160 ≤1 watt 2 Low Voltage : ≥0.517 x Pno + 0.087 1 Basic Voltage : ≥0.071 x Ln(Pno) - 0.0014 ≤0.100 ≥0.9 at x Pno + 0.67 >1 to ≤49 watts 115Vac/60Hz 2 Low Voltage : ≥0.0834 x Ln(Pno) - 0.0014 for power VI x Pno + 0.609 supply with 1 Basic Voltage : ≥0.880 input power >49 to ≤250 watts ≤0.210 ≥100 watts 2 Low Voltage : ≥0.870 1 Basic Voltage : ≥0.875 >250 watts ≤0.500 2 Low Voltage : ≥0.875 TABLE IIa. Efficiency Level Requirements: Single-Output * Excluding any devce that requires Federal Food and Drug Administration (FDA) listing and approval as a medical device. Consult DoE 10 CFR Part 430 for more details. 1) Basic Voltage: nameplate voltage ≥ 6V. 2) Low Voltage: nameplate output voltage < 6V and nameplate output current ≥550mA. AN-G-001/15 | Page 3 APPLICATION NOTE Performance Requirements – Multiple-Voltage External AC-DC Power Supply Level Nameplate Minimum Average Efficiency in Active Mode Maximum Power in Output Power (expressed as a decimal) No-Load Mode (W) (Pno) <1 watt ≥0.497 x Pno + 0.067 1 to ≤49 watts ≥0.075 x Ln(Pno) + 0.561 ≤0.300 VI >49 watts ≥0.860 TABLE IIb. Efficiency Level Requirements: Multiple-Output Definitions: Direct operation external power supply: an external power supply (EPS) that functions in its end product without the assistance of a battery. External Power Supply (EPS): is an external power supply circuit with its own housing used to covert line voltage AC input into lower voltage AC or DC output electric current, intended to be used with a separate end-use product and connected via either hardwired or connectorized cable or wiring. Indirect operation external power supply: an external power supply that cannot operate the end product without the assistance of a battery and is not a battery charger. Pno: nameplate output power. Ln: natural logarithm. Active mode: The condition in which the input of a power supply is connected to line voltage AC and the output is connected to a DC load drawing a fraction of the power supply’s nameplate power output greater than zero. No-load mode: The condition in which the input of a power supply is connected to an AC source consistent with the power supply’s nameplate AC voltage, but the output is not connected to a product or any other load. Power Factor (true): The true power factor is the ratio of the active, or real, power (P) consumed in watts to the apparent power (S), drawn in volt-amperes (VA). Basic voltage external power supply: an EPS with a nameplate output voltage of greater than or equal to 6 volts. Low voltage external power supply: an EPS with a nameplate output voltage of less than 6 volts and a nameplate output current greater than or equal to 550 milliamps. Test Methodology: The unit under test (UUT) shall be tested at two voltage and frequency combinations: 115Vac, 60 Hz and 230Vac, 50 Hz, if its nameplate input voltage and frequency indicate AN-G-001/15 | Page 4 I SL Power Electronics I I SL Power Electronics I APPLICATION NOTE that it can operate safely under both conditions. The input voltage source shall be capable of delivering at least 10 times the nameplate input power of the UUT (as specified in IEEE 1515-2000). Regardless of the AC source type, the THD (total harmonic distortion) of the supply voltage when supplying the UUT in the specified mode shall not exceed 2%, up to and including the 13th harmonic (as specified in IEC 62301). The peak value of the test voltage shall be within 1.34 and 1.49 times its RMS value (as specified in IEC 62301). The power measurement instrument shall have a resolution of 0.01W or better for power measurements of 10W or less, 0.1W or better for power measurements of greater than 10W up to 100W, and 1W or better for power measurements of greater than 100W. The UUT shall be tested at the load conditions shown in Table III: LOAD CONDITION OUTPUT CURRENT 1 100% ±2% 2 75% ±2% 3 50% ±2% 4 25% ±2% 5 0% TABLE III. Percentage of Nameplate Output Current The UUT shall be operated at 100% of nameplate output current for at least 30 minutes. After this warm-up period, if the power level does not drift by more than 5% from the maximum value observed, the UUT can be considered stable and the measurements can be recorded. If AC input power is not stable over a 5 minute period, the guidelines established by IEC 62301 for measuring average power or accumulated energy over time for both AC input and DC output are followed. Efficiency measurements shall be conducted in sequence from Load Condition 1 to Load Condition 5 as indicated in the table above. Efficiency shall be calculated by dividing the UUT’s measured DC output power at a given load condition by the true AC input power measured at that load condition. Average efficiency shall also be calculated as the arithmetic mean of the efficiency values calculated at Load Conditions 1, 2, 3, and 4. It is critical to use a short and properly sized test cable to reduce cable power loss as much as possible. It is also recommended to measure the output voltage right at the output connector, not through a mating connector. Significant losses may result from the mating connector. Compliance Date: The compliance date for the DOE Level VI regulations is February 10, 2016. Compliance will be based on the date of manufacture and/or date of import into the United States. Any power supply manufactured after this date must comply with the new regulations. AN-G-001/15 | Page 5 North America SL Power Electronics Headquarters 6050 King Drive Ventura, CA 93003 Phone: 800-235-5929 Fax: 805-832-6135 Email: info@slpower.com Sales & Engineering Office - East Coast USA 607 Neponset Street Canton, MA 02121 Phone: 800-235-5929 Fax: 858-712-2040 Email: info@slpower.com Europe Sales & Engineering Office Unit 1 (c/o Davall Gears Ltd) Travellers Lane, Welham Green Hatfield, Hertfordshire AL9 7JB UK Phone: +44 (0) 1769 581311 Fax: +44 (0) 1769 612763 Email: euinfo@slpower.com Asia Sales & Engineering Office Fourth Floor Building 53 1089 Qing Zhou Road North Shanghai, China 200233 Phone: +86 21 64857422 Fax: +866 21 64857433 Email: infor@slpower.com SLpower.com © 2016 SL Power Electronics
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the PW174KB1503F01?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers





What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods