Specifications
Manufacturer
SL Power
Manufacturers Part #
TE30A1503C01
Selling Alternatives
CENB1030A1503C01, CENB1030A1503B01
Brand
Ault
Series
TE30
Factory Pack Quantity
1
Dimensions
3.80 x 2.20 x 1.30"
Isolation
4000 VAC
Mechanical Style
External
Mounting
Wall Mount
Number of Outputs
1
Operating Temperature
- 20 to + 70°C
Output Amps 1
2 A
Output Voltage V1 Nominal
15 VDC
Power
30 W
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
TE30 20W-30W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 30W of AC-DC Power Universal Input 90-264Vac Input Range Desktop and Wall-Plug versions Meets “Heavy Industrial” Levels of EN61000 EMC Requirements Meets EN55032/CISPR22 and FCC Part 15.109 Class B Conducted & Radiated Emissions, with 6db margin nd Approved to EN/IEC/UL60950-1, 2 Ed., Am. 2 E-cap life of >8 years >1,000,000 hours MTBF 3 Year Warranty Description A high performance AC to DC external power supply family designed for test & measurement and industrial applications. The TE30A Series models are compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, PLUS Heavy Industrial levels of various EN61000-4-x standards for EMC. Model Selection Model Output Output Ripple & Line Load Output Input Connector Configuration Number Volts Current Power Noise¹ Regulation Regulation TE30A0503F01 5.0V 4.00A 20W 75mV pk-pk ±1% ±5% TE30A0903F01 9.0V 3.00A 27W 90mV pk-pk ±1% ±5% TE30A1203F01 12.0V 2.50A 30W 120mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm Class I Desktop, TE30A1503F01 15.0V 2.00A 30W 150mV pk-pk ±1% ±5% Straight Barrel Type, IEC60320 C14 TE30A1803F01 18.0V 1.67A 30W 180mV pk-pk ±1% ±5% center positive Receptacle TE30A2403F01 24.0V 1.33A 30W 240mV pk-pk ±1% ±5% TE30A4803F01 48.0V 0.63A 30W 480mV pk-pk ±1% ±5% TE30A0503N01 5.0V 4.00A 20W 75mV pk-pk ±1% ±5% TE30A0903N01 9.0V 3.00A 27W 90mV pk-pk ±1% ±5% TE30A1203N01 12.0V 2.50A 30W 120mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm Class II Desktop, TE30A1503N01 15.0V 2.00A 30W 150mV pk-pk ±1% ±5% Straight Barrel Type, IEC60320 C8 TE30A1803N01 18.0V 1.67A 30W 180mV pk-pk ±1% ±5% center positive Receptacle TE30A2403N01 24.0V 1.33A 30W 240mV pk-pk ±1% ±5% TE30A4803N01 48.0V 0.63A 30W 480mV pk-pk ±1% ±5% TE30A0503Q01 5.0V 4.00A 20W 75mV pk-pk ±1% ±5% TE30A0903Q01 9.0V 3.00A 27W 90mV pk-pk ±1% ±5% TE30A1203Q01 12.0V 2.50A 30W 120mV pk-pk 2.5 x 5.5 x 9.5mm Class II Desktop, ±1% ±5% TE30A1503Q01 15.0V 2.00A 30W 150mV pk-pk ±1% ±5% Straight Barrel Type, IEC60320 C18 TE30A1803Q01 18.0V 1.67A 30W 180mV pk-pk ±1% ±5% center positive Receptacle TE30A2403Q01 24.0V 1.33A 30W 240mV pk-pk ±1% ±5% TE30A4803Q01 48.0V 0.63A 30W 480mV pk-pk ±1% ±5% TE30A0503B01 5.0V 4.00A 20W 75mV pk-pk ±1% ±5% TE30A0903B01 9.0V 3.00A 27W 90mV pk-pk ±1% ±5% Class II Wall-Plug, TE30A1203B01 12.0V 2.50A 30W 120mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm Interchangeable TE30A1503B01 15.0V 2.00A 30W 150mV pk-pk ±1% ±5% Straight Barrel Type, Blades (North TE30A1803B01 18.0V 1.67A 30W 180mV pk-pk ±1% ±5% center positive American Blade included)² TE30A2403B01 24.0V 1.33A 30W 240mV pk-pk ±1% ±5% TE30A4803B01 48.0V 0.63A 30W 480mV pk-pk ±1% ±5% TE30A0503C01 5.0V 4.00A 20W 75mV pk-pk ±1% ±5% TE30A0903C01 9.0V 3.00A 27W 90mV pk-pk ±1% ±5% TE30A1203C01 12.0V 2.50A 30W 120mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm Class II Wall-Plug, TE30A1503C01 15.0V 2.00A 30W 150mV pk-pk ±1% ±5% Straight Barrel Type, Fixed North TE30A1803C01 18.0V 1.67A 30W 180mV pk-pk ±1% ±5% center positive American Blades³ TE30A2403C01 24.0V 1.33A 30W 240mV pk-pk ±1% ±5% TE30A4803C01 48.0V 0.63A 30W 480mV pk-pk ±1% ±5% Notes: 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. For 5V and 6V models, values listed are typical, 100mV pk-pk maximum with 0.1μF ceramic and 47μF low ESR capacitors used at measurement point. 2. Order blade kit KT-1027K for other blades (EU. UK, Australia) 3. For EU fixed blades, replace “C” in the model number with “M”, for UK blades, replace “C” with “G”, for Australia blades, replace “C” with “H”. 4. All specifications are typical at nominal input, full load, at 25C ambient unless noted. 5. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE30B1203F01). www.slpower.com TE30 Rev 1.8 5-JAN-17 1 TE30 20W-30W Single Output External Power Test & Measurement/Industrial Series General Specifications Less than 700mS @115Vac, full load AC Input 100-240Vac, ±10%, 47-63Hz, 1∅ Turn On Time Input Current 115Vac: 1.2A, 230Vac: 0.6A Hold-up Time 20mS min., at full Load, 100Vac input Overtemperature Will shutdown upon an overtemperature Inrush Current 264Vac, cold start: will not exceed 40A condition, auto-recovery. Protection Input Fuse 2.0A, 250Vac Overload Protection 130 to 180% of rating, Hiccup Mode Earth Leakage Input-GND: <500μA@264Vac, 60Hz, NC Short Circuit Hiccup Mode, auto recovery. Current Output-GND: <4mA@264Vac, 60Hz, NC Protection Overvoltage Meets US DoE Efficiency Level VI Average Hiccup Mode. See model chart above for Efficiency efficiency levels trip ranges. Protection Input-Output: 4000Vac 20 to 30W continuous – See models chart for Output Power Isolation Input-Ground: 1500Vac specific voltage model ratings. Output-Ground: 1500Vac No Load Input <0.1W per DoE Efficiency Level VI Safety Standards EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2 Requirements Power -20°C to +70°C Operating Ripple and Noise See models chart on pg 1. Start Up at -40°C, full load, (warmup period before Temperature all parameters are within published specifications). Temperature Output Voltage See models chart on pg 1. See Derating Charts below. Derating 500µs response time for return to within 0.5% Transient of final value for any 50% load step over the -40°C to +85°C Storage Temperature range of 5% to 100% of rated load,∆i/∆t< Response 0.2A/µs. Max. voltage deviation is +/-3.5%. Operating: to 5000m. Regulation See models chart on pg 1. Altitude Non-operating: -500 to 40,000 ft. 1.4m from table top to wooden platform, 4 5% to 95%, non-condensing Drop Test Relative Humidity faces. Operating: 0.003g/Hz, 1.5grms overall, 3 Operating: Half-sine, 20gpk, 10mS, 3 axes, axes, 10 min/axis, 1-500Hz. 6 shocks total Non-Oper.: random waveform, 3 minutes per Non-Operating: Half-sine waveform, impact Vibration axis, 3 axes and Sine waveform, Vib. Shock acceleration of 100G, Pulse duration of 6 frequency/acceleration: 10-500Hz/1g, sweep mS, Number of shocks: 3 for each of the rate of 1 octave / minutes, Vibration time of 10 three axis sweeps / axes, 3 axes >1,000,000 hours, full load, 110 & 220Vac Dimensions See outline drawings MTBF input, 25°C amb., per Telcordia 332 Issue 6. >8 year life based on calculations at 115Vac/60Hz & 230Vac/50Hz, ambient 25°C Weight 250g E-Cap Life at 24 hrs per day, 365 days/year, 6 power up cycles per day. All specifications are typical at nominal input, full load, at 25°C ambient unless noted. www.slpower.com TE30 Rev 1.8 5-JAN-17 2 TE30 20W-30W Single Output External Power Test & Measurement/Industrial Series EMI/EMC Compliance Conducted Emissions: EN55032/CISPR22 Class B, FCC Part 15, Class B: 6db margin typ, at 115 and 230Vac Radiated Emissions: EN55032/CISPR22 Class B, FCC Part 15, Class B: 3db margin typ, at 115 and 230Vac Common Mode Noise: High Frequency (100kHz-20MHz): <40mA pk-pk Electro-Static Discharge (ESD) EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A Immunity on Power ports: EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz Radiated RF EM Fields Susceptibility Electrical Fast Transients (EFT) /Bursts: EN55024/IEC61000-4-4, Level 4, +/- 4.4kV, 100Khz rep rate, 40A, Criteria A Surges, Line to Line (Diff Mode) and Line EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A to GND (CMN Mode) Conducted Disturbances induced by RF EN55022/IEC61000-4-6, 3.6V/m – Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz Fields Rated Power frequency magnetic fields EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz EN55024/IECEN61000-4-11: --100% dip for 20mS, Criteria A Voltage Interruptions, Dips, Sags & --100% dip for 5000mS (250/300 cycles), Criteria B Surges --60% dip for 100mS, Criteria B --30% dip for 500mS, Criteria A Harmonic Current Emissions EN55011/EN61000-3-2, Class A Flicker Test EN61000-3-3 All specifications are typical at nominal input, full load, at 25°C ambient unless noted. Output Power Derating Output power is derated above 40°C as follows, for operation over the entire AC input range (90-264Vac). 35 30 25 20 5V Models 15 9V Models 12V-48V Models 10 5 0 -20° -10° 0° 10° 20° 30° 40° 50° 60° 70° Ambient Operating Temperature (°C) www.slpower.com TE30 Rev 1.8 5-JAN-17 3 Output Power TE30 20W-30W Single Output External Power Test & Measurement/Industrial Series Mechanical Drawing 54 33.6 55 Cable length for 5V and 9V models is 1200 +/- 50mm Cable length for 5V and 9V models is 1200 +/- 50mm IEC60320 C14 Receptacle, 2.5 x 5.5 x 9.5mm Barrel Connector Interchangeable N.A. Blade, 2.5 x 5.5 x 9.5mm barrel connector Notes: 1. All dimensions in mm. 2. Interchangeable blade models come with North American blade fitted. For other blades (EU, UK, Aust.) order blade kit KT1027K. Connector Information Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. Other standard options are listed below. The “03” in the standard model number is replaced by the applicable digits below: www.slpower.com TE30 Rev 1.8 5-JAN-17 4 95.5 1450±50 96 1450±50 TE30 20W-30W Single Output External Power Test & Measurement/Industrial Series Efficiency Level VI Information: TE30A Series 9V-48V models TE30A Series 5V models Data Sheet © 2017 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com TE30 Rev 1.8 5-JAN-17 5
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the TE30A1503C01?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers





What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods