SL POWER TE90A1503F01
Specifications
Manufacturer
SL Power
Manufacturers Part #
TE90A1503F01
Selling Alternatives
CENB1090A1503F01, CENB1080A1503F01
Brand
Ault
Series
TE90
Factory Pack Quantity
1
Application
External Power Supply
Compliance
Level VI
Dimensions
5.91 x 2.58 x 1.34"
Environmental Conditions
General Purpose
Industry
Industrial
Input Type
AC
Isolation
Class I, Class II
Mechanical Style
External
Number of Outputs
1
Operating Temperature
0 to +40°C, Full Load
Output Amps 1
6 A
Output Voltage V1 Nominal
15 V
Package Type
Desktop
Power
90 W
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
TE90 90W Single Output External Power Test & Measurement/Industrial Series Features Meets U.S. DoE Efficiency Level VI and EU CoC Tier 2 Requirements No load input power Average Efficiency Up to 90W of AC-DC Power Universal Input 90-264Vac Input Range IP22 Rated Enclosure Meets “Heavy Industrial” Levels of EN61000 EMC Requirements Meets EN55011/CISPR11, FCC Part 15.109 Class B Conducted & Radiated Emissions, with 6db margin nd Approved to EN/IEC/UL60950-1, 2 Edition, Am. 2 E-cap life of >7 years 3 Year Warranty RoHS/REACH Compliant Description A high performance AC to DC external power supply family designed for test & measurement and industrial applications. Fully compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, and also compliant to the Heavy Industrial levels of various EN61000-4-x standards for EMC. The TE90 series models also meet Class B conducted and radiated EMI per FCC Part 15, EN55022, CISPR22, with margin. Designed to allow easy integration with test and measurement equipment and other industrial applications. Model Selection Model Output Output Ripple & Line Load Output Cable Input & Connector Configuration Number Volts Current Power Noise¹ Regulation Regulation 2 TE90A1251F01 12.0V 7.50A 90W 120mV pk-pk 6 pin Molex Type ±1% ±5% Class I Desktop, TE90A1503F01 15.0V 6.00A 90W 150mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm IEC60320 C14 TE90A1803F01 18.0V 5.00A 90W 180mV pk-pk ±1% ±5% Straight Barrel Type, Receptacle center positive TE90A2403F01 24.0V 3.75A 90W 240mV pk-pk ±1% ±5% 2 TE90A1251N01 12.0V 7.50A 90W 120mV pk-pk ±1% ±5% 6 pin Molex Type Class II Desktop, TE90A1503N01 15.0V 6.00A 90W 150mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm IEC60320 C8 TE90A1803N01 18.0V 5.00A 90W 180mV pk-pk Straight Barrel Type, ±1% ±5% Receptacle center positive TE90A2403N01 24.0V 3.75A 90W 240mV pk-pk ±1% ±5% 2 TE90A1251Q01 12.0V 7.50A 90W 120mV pk-pk ±1% ±5% 6 pin Molex Type Class II Desktop, TE90A1503Q01 15.0V 6.00A 90W 150mV pk-pk ±1% ±5% 2.5 x 5.5 x 9.5mm IEC60320 C18 TE90A1803Q01 18.0V 5.00A 90W 180mV pk-pk Straight Barrel Type, ±1% ±5% Receptacle center positive TE90A2403Q01 24.0V 3.75A 90W 240mV pk-pk ±1% ±5% Notes: 1. Measured at the output connector, with noise probe directly across output and load, terminated with 0.1μF ceramic and 47μF low ESR capacitors. 2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information. 3. For Input Class I models: For AC GND connected to output common (-), insert a “B” in the part number where the “A” is located (TE90B1251F01). 4. All specifications are typical at nominal input, full load, at 25°C ambient unless noted. www.slpower.com TE90 Rev 2.2 01-DEC-16 1 TE90 90W Single Output External Power Test & Measurement/Industrial Series General Specifications AC Input 100-240Vac, ±10%, 47-63Hz, 1∅ Turn On Time Less than 1 sec @115Vac, full load Input Current 115Vac: 1.2A, 230Vac: 0.6A Hold-up Time 20mS min., at full Load, 100Vac input Overtemperature Will shutdown upon an over-temperature Inrush Current 264Vac, cold start: will not exceed 60A condition, auto-recovery. Protection F1, F2: 5A, 250Vac fuses (line & neutral lines) Input Fuses Overload Protection 130 to 180% of rating, Hiccup Mode provided on all models Earth Leakage Input-GND: <500μA@264Vac, 60Hz, NC Short Circuit Hiccup Mode, auto recovery. Output-GND: <4mA@264Vac, 60Hz, NC Current Protection Meets US DoE Efficiency Level VI and EU Overvoltage 130 to 150% of output voltage (max. 60V on Efficiency CoC Tier 2 average efficiency levels Protection 48V model), hiccup mode Input-Output: 4000Vac 90W continuous – See models chart for Output Power Isolation Input-Ground: 1500Vac specific voltage model ratings. Output-Ground: 1500Vac No Load Input <0.150W, Meets DoE Efficiency Level VI and Safety Standards EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2 EU CoC Tier 2 Requirements Power Operating Ripple and Noise See models chart on pg 1. -20°C to +70°C. Derate above 40°C. Temperature Case Temperatures are within regulatory guidelines. Care should be taken to avoid Output Voltage See models chart on pg 1. Case Temperature prolonged contact with skin or other heat sensitive surfaces. 500µs response time for return to within 0.5% Transient of final value for any 50% load step over the Temperature See Derating Chart range of 5% to 100% of rated load,∆i/∆t< Response Derating 0.2A/µs. Max. voltage deviation is +/-3.5%. >7 year life based on calculations at >500,000 hours, full load, 110 & 220Vac 115Vac/60Hz & 230Vac/50Hz, ambient 25°C E-Cap Life MTBF at 24 hrs per day, 365 days/year, 6 power up input, 25°C amb., per Telcordia 332 Issue 6. cycles per day. (80% load on 12V model) Weight 600g Storage Temperature -40°C to +85°C Operating: to 5000m (derate to TBD temp. 1.4m from table top to wooden platform, 6 Safety Drop Test Altitude above 3000m). faces. Non-operating: -500 to 40,000 ft. W: 2.67” x L: 6.02” x H: 1.36” 5% to 95%, non-condensing Dimensions Relative Humidity W: 68mm x L: 153mm x H: 34.5mm Operating: 0.003g/Hz, 1.5grms overall, 3 Operating: Half-sine, 20gpk, 10mS, 3 axes, axes, 10 min/axis, 1-500Hz. 6 shocks total Non-Oper.: random waveform, 3 minutes per Non-Operating: Half-sine waveform, impact Vibration axis, 3 axes and Sine waveform, Vib. Shock acceleration of 100G, Pulse duration of 6 frequency/acceleration: 10-500Hz/1g, sweep mS, Number of shocks: 3 for each of the rate of 1 octave / minutes, Vibration time of 10 three axis sweeps / axes, 3 axes All specifications are typical at nominal input, full load, at 25°C ambient unless noted. www.slpower.com TE90 Rev 2.2 01-DEC-16 2 TE90 90W Single Output External Power Test & Measurement/Industrial Series EMI/EMC Compliance Conducted Emissions: EN55011/CISPR22 Class B, FCC Part 15.107, Class B: 6db margin typ, at 115 and 230Vac EN55022/CISPR22 Class B, FCC Part 15.109, Class B: 3db margin typ, at 115 and 230Vac Radiated Emissions: High Frequency (100kHz-20MHz): <40mA pk-pk Common Mode Noise: Electro-Static Discharge (ESD) EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A Immunity on Power ports: Radiated RF EM Fields Susceptibility EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz Electrical Fast Transients (EFT) /Bursts: EN55024/IEC61000-4-4, Level 4, +/- 4kV, 100Khz rep rate, 40A, Criteria A Surges, Line to Line (Diff Mode) and Line EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A to GND (CMN Mode) Conducted Disturbances induced by RF EN55022/IEC61000-4-6, 10Vrms – Level 4, in ISM and amateur radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz Fields EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz Rated Power frequency magnetic fields EN55024/IECEN61000-4-11: --100% dip for 10 mS, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees; 20mS at 0 degrees. Voltage Interruptions, Dips, Sags & Criteria A --100% dip for 5000mS (250/300 cycles), Criteria B Surges --60% dip for 100mS, Criteria B --30% dip for 500mS, Criteria A Harmonic Current Emissions EN55011/EN61000-3-2, Class A Flicker Test EN61000-3-3 Notes: Performance criteria are based on EN55024. According to the standards, performance criteria are defined as following: A – Normal performance during and after the test B – Temporary degradation, self-recoverable C – Temporary degradation, operator intervention required to recover the operation D – Permanent damage Derating Chart: 100 90 80 70 60 50 12V-24V 40 30 20 10 0 -20 -10 0 10 20 30 40 50 60 70 Ambient Temperature -ͦC www.slpower.com TE90 Rev 2.2 01-DEC-16 3 Output Power - Wwatts TE90 90W Single Output External Power Test & Measurement/Industrial Series Mechanical Drawing: 15V through 24V Models: 2.5 x 5.5 x 9.5mm 12V Models: Output Connector: 6 pin Molex 39-01-2060 Barrel Connector, center positive. or equiv. Pins 1, 4 = (+), pins 3, 6 = (-), pins 2, 5 = NC Notes: 1) All dimensions in mm. 2) The unit should not be covered or enclosed to protect against excessive case temperature rise. Connector Information Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. (#51 for the 12V models). Other standard options are listed below. The “03” in the standard model number is replaced by the applicable digits below: www.slpower.com TE90 Rev 2.2 01-DEC-16 4 TE90 90W Single Output External Power Test & Measurement/Industrial Series Efficiency Level VI Information: TE90A Series Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com TE90 Rev 2.2 01-DEC-16 5
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the TE90A1503F01?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers





What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods