Electronics Finder chervon right Manufacturers chervon right T chervon right TE CONNECTIVITY chervon right 1472962-1
About product Specifications Datasheet FAQ

TE CONNECTIVITY 1472962-1

Image of TE CONNECTIVITY 1472962-1

Description

Time Delay Relay 48VDC 48VAC 10A DPDT(50x50x83)mm Plug-In
1472962-1

Part Number

1472962-1

Price

Request Quote

Manufacturer

TE CONNECTIVITY

Lead Time

Request Quote

Category

Relays and I/O Modules »  Time Delay Relay

Specifications

Manufacturer

TE Connectivity

Manufacturers Part #

1472962-1

Industry Aliases

1472962-1

Sub-Category

Time Delay Relays

Brand

P&B

Factory Pack Quantity

1

Datasheet

pdf file

DDEController?Action=srchrtrv&DocNm=5-1773450-5_Section12&DocType=CS&DocLang=English&s_cid=1046.pdf

5435 KiB

Extracted Text

Specialty Relays Specialty Relays Table of Contents MDR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-2, 12-3 2100 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-4 – 12-7 7000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-8 – 12-14 E7000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-15 – 12-20 EGP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-21 – 12-27 EML Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-21 – 12-27 ETR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-21 – 12-27 GP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-28 – 12-30 ML Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-28, 12-29, 12-32 TR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-28, 12-31, 12-32 VCA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-33 VMA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-34 SCB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-35 SCC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-35 SCE Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-36 SCF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-37 SRC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-38 SSC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-39 SSF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-40 SST Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-41 STA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-42 VTM1 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-43 VTM-1 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-44 VTM2 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-45 12 VTM3 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-46 VTM4 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-47 VTM7 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-48 VTMA1 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-49 VTMR1 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-50 12–1 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays MDR Series, 10 Amp Rotary Relay For Demanding Shock & Vibration Applications Product Facts n AC and DC coils, latching and non-latching n 4PDT through 24PDT contact arrangements n Designed to withstand high impact shock per MIL-S-901 Small 8PDT Medium 24PDT Operate Data @ 77°F [25°C] Specifications Typ. Operate Typ. Release Type Contact Data Time (ms) Time (ms) Arrangements — 4 Form C (4PDT) Small AC Non-Latching 5 to 12 5 to 18 through 24 Form C (24 PDT). Small DC Non-Latching 15 to 30 5 to 15 Small AC Latching 6 to 12 N/A Contact Ratings Small DC Latching 10 to 16 N/A Single Two Contacts Contacts in Series Medium AC Non-Latching 6 to 12 6 to 20 10 A, 3 A, Medium DC Non-Latching 65 to 90 10 to 30 115 VAC 440 VAC Medium AC Latching 50 (max.) N/A 3 A, 15 A, Medium DC Latching 30 to 80 N/A 28 VDC 115 VAC 0.8 A, 1.5 A, 125 VDC 125 VDC Latching Two-Position Types — Except for the latching feature, MDR The above AC contact ratings are based on contact loads having a latching relays utilize the same general 50% power factor. The DC contact construction as non-latching types. They ratings are based on resistive loads. have two sets of coils and provide a latching two-position operation. Contact Section L M K 1 3 A J Coil Coil B H Contacts Shown With Coil 1-2 De-Energized G C 2 4 and Coil 3-4 Energized. Fixed F D E Contact Coils Must be Energized Alternately, Not Simultaneously. Environmental Data Temperature Range — Standard models — 0°F to +149°F [0°C to +65°C] Special order models — 0°F to +194°F [0°C to +90°C] Mechanical Data Termination — #5-40 screw terminals supplied Weight (Approx.) — Small — 4 & 8PDT — 32 oz. [0.914 kg]; 12PDT — 33 oz. [0.943 kg] Medium — 16PDT — 72 oz. [2.04 kg]; 24PDT — 74 oz. [2.10 kg] 12–2 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. G J H K J L Specialty Relays K M L A M B Specialty Relays MDR Series, 10 Amp Rotary Relay For Demanding Shock & Vibration Applications (Continued) Ordering Information and Coil Characteristics — No models in this series are maintained in stock. Coil Voltage Part Coil Power* Breakdown Type Contacts (60 Hz. Number (Watts) (Volts RMS) for AC) MDR-131-1 4PDT 115 VAC 6.5 1,230 MDR-131-2 4PDT 440 VAC 5.1 1,880 MDR-135-1 4PDT 28 VDC 10.0 1,308 MDR-137-8 4PDT 125 VDC 10.3 2,375 MDR-134-1 8PDT 115 VAC 6.5 1,230 Small Non-Latching MDR-134-2 8PDT 440 VAC 5.1 1,880 MDR-136-1 8PDT 28 VDC 10.0 1,308 MDR-138-8 8PDT 125 VDC 10.3 2,375 MDR-163-1 12PDT 115 VAC 6.9 1,230 MDR-163-2 12PDT 440 VAC 6.3 1,880 MDR-170-1 16PDT 115 VAC 17.0 1,230 MDR-170-2 16PDT 440 VAC 17.0 1,880 MDR-172-1 16PDT 28 VDC 18.7 1,308 Medium MDR-173-1 16PDT 125 VDC 16.0 2,375 Non-Latching MDR-141-1 24PDT 115 VAC 17.0 1,230 MDR-141-2 24PDT 440 VAC 17.0 1,880 MDR-167-1 24PDT 28 VDC 18.7 1,308 MDR-142-1 24PDT 125 VDC 16.0 2,375 MDR-67-2 4PDT 115 VAC 5.5 1,230 MDR-4091 4PDT 440 VAC 3.0 1,880 MDR-67-3 4PDT 28 VDC 21.8 1,308 MDR-5060 4PDT 125 VDC 20.6 2,375 Small Latching MDR-4076 8PDT 115 VAC 5.5 1,230 MDR-4092 8PDT 440 VAC 3.0 1,880 MDR-5035 8PDT 28 VDC 21.8 1,308 MDR-5061 8PDT 125 VDC 20.6 2,375 MDR-6064 12PDT 115 VAC 12.0 1,230 MDR-6065 12PDT 440 VAC 5.7 1,880 MDR-7020 12PDT 28 VDC 8.8 1,308 Note: All values are for reference, MDR-7035 12PDT 125 VDC 10.4 2,375 Medium specific values may be different and 12 Latching MDR-66-4 16PDT 115 VAC 12.0 1,230 subject to environmental factors MDR-6066 16PDT 440 VAC 5.7 1,880 such as temperature, humidity, MDR-7025 16PDT 28 VDC 8.8 1,308 pressure or variations in voltage. MDR-7036 16PDT 125 VDC 10.4 2,375 *Actual Wattmeter readings. Outline Dimensions Tolerances: Decimals ± .010 [±.25] Unless Otherwise Specified. Small Models Medium Models .196 .005 Dia. .281 .005 6 [4.98 .13] Dia. [7.14 .13] 4 Plcs. 3 5 4 Plcs. 2 4 1 3 2 1 12 2.125 Coil 12 [53.98] Overall Height 3.250 2.625 [82.55] 4PDT 3.13 [79.5] Max. [66.68] (2X) 8PDT 3.53 [89.7] Max. 4.190 Coil 12PDT 3.88 [98.6] Max. [106.43] 2X Overall Height Coil and Contact Terminal Screws 12PDT 4.63 [117.6] Max. #5-40 Supplied. 16PDT 5.00 [127.0] Max. 24PDT 5.75 [146.1] Max. Coil and Contact Terminal Screws #5-40 Supplied. 12–3 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. A C B C D E D F E F G H Specialty Relays AGASTAT 2100 Series, Miniature Electropneumatic Timing Relay Repeat Accuracy — NORMAL VER TI CAL PO SI TION Operation ±5% at 25°C; ±7% at 85°C; ±8% at -55°C. Series 2112 The average time between -55°C and 85°C will be within ±20% of the average @ (On-Delay) — 25°C with a pro por tion al ly reduced effect at lesser extremes. Ap ply ing rated volt- In extremely short delay settings an additional 8 msec. vari a tion may result on AC age to the solenoid models due to "half cycle" al ter nat ing current effect. coil starts the pre set time de lay. At the Setting Tolerance — Factory time setting, when specified, subject to ad di tion al end of the delay pe - +5% tolerance. ri od the NC con tacts break and the NO Position Sensitivity — con tacts make. Con tacts re main in this HORIZONTAL POSITION — Approximately 5% increase from the initial time in the po si tion un til the coil is de-en er gized, vertical position. when the switch in stan ta neous ly re turns INVERTED POSITION — Approximately 10% increase from the initial time in the ver- to its orig i nal po si tion. De-en er giz ing ti cal position. Product Facts the coil, ei ther during or after the de lay Re set Time — 2112 Series: 25 msec.; 2122 Series: 75 msec. pe ri od, will im me di ate ly (with in 25 msec.) n High Repeat Accuracy over Relay Release Time — 25 msec. (2112 Series) re cy cle the unit. It will then provide an- voltage and temperature oth er full delay period on re-energization. Relay Operate Time — 75 msec. (2122 Series) extremes Series 2122 Operating Voltage — Coil Data n Hermetically sealed units (Off-Delay) — Nominal Re sis tance Ap ply ing rated volt- Code Operating Ohms are designed for high shock Voltage ±10% age to the coil for at and vibration applications M 12VDC 30 least 75 msec. (for n Instant recycling — accurate timing) will N 28VDC 131 easy linear adjustment in stan ta neous ly P 48VDC 500 transfer the switch, R 110VDC 3200 n Exclusive Dial Head break ing the NC con tacts and mak ing S 120V 60 Hz 190 (2112 Series) adjustment — no needle the NO contacts. Contacts re main in this S 120V 60Hz 285 (2122 Series) valves position as long as the coil is energized. T 240V 60Hz 765 The pre set time delay period begins as n Delay ranges from U 115V 400Hz 2600 soon as the coil is de-energized, at the milliseconds to 3 minutes Y 125VDC 3380 end of which the switch re turns to its n DPDT contacts original po si tion. No power is Transients — Insensitive to transients of ±1500 VAC for 10 mil li sec onds required during the tim ing period. Dielectric — 1000V RMS @ 60Hz between non-connected ter mi nals. Re-energizing the coil, either during or Design & Construction Contact Rating (DPDT Contacts) — after the delay period, will immediately Sealed patented timing head — 30V 110V 120V 120V 240V start a new cycle with full delay period. DC DC 60Hz 400Hz 60Hz cir cu lates air un der con trolled pressure Operation (Listed values at nom. Inductive (Amps) 2 .75 3 2 1.5 through a vari able or i fice to pro vide ad- voltage, 25°C unless noted) just able tim ing. Cir cu lar-path Dial Head Resistive (Amps) 10 1 10 10 5 prin ci ple re plac es tra di tion al needle valve. Operating Mode — Based on 100,000 operations electrical, 1,000,000 me chan i cal. Inductive and capaci- Snap-action switch as sem bly — 2112 — On-delay (delay on pull-in); tive load should not have inrush currents that exceed five times normal op er at ing load. pro vides sus tained contact pres sure dur- 2122 — Off-delay (delay on drop-out) Ambient Temperature Range — -55°C to +85°C ing tim ing cy cles. Spe cial ly de signed Timing Adjustment — All standard Weight — Maximum, any unit - 17 ozs. over cen ter mech a nism as sures flut ter-free models of fer easy lin ear ad just ment over Mounting/Terminals — Chassis mounting tabs, octal plugs and external (-4) or load trans fer after ex tende d de lay periods. one of nine tim ing ranges listed below. in ter nal (-5) adjustment. Panel mounting back plate, internal ad just ment, and solder For ap pli ca tions requiring frequent re ad- Precision-wound solenoid hook terminals (-9). just ment, the external knob model is rec- as sem bly — supplies the ba sic mo tive ommended. For tamper-proof force when the con trol cir cuit is closed. installation or where readjustment is These assemblies are mounted in a rigid infrequent, the internal key model may self-sup port ing frame work within a steel be pre ferred. This model requires enclosure. This rug ged con struc tion as - removal of the cover plate for timing ad - sures permanent align ment of all op er at- just ment. Her met i cal ly sealed mod els ing mem bers, the key to this unit's long provide a slot ted adjusting screw under trou ble-free operation. the cap nut on the top cover. Timing Ranges — Code Range A .03 to .1 sec. B .1 to .3 sec. C .15 to 1.0 sec. Users should thoroughly review the technical data before selecting a product D .375 to 3.0 sec. part number. It is recommended that E .75 to 10.0 sec. -4 -5 -9 users also seek out the pertinent F 1.0 to 30.0 sec. approvals files of the agencies/laborato- G 2.0 to 60.0 sec. These are minimum stan dards; where more se vere environmen- ries and review them to ensure the prod- tal con di tions must be met, please con sult the factory. H 5.0 to 120.0 sec. uct meets the requirements for a given J 5.0 to 180.0 sec. application. K 1.5 to 30.0 cycles L 3.0 to 120.0 cycles 12–4 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays AGASTAT 2100 Series, Miniature Electropneumatic Timing Relay (Continued) Outline Dimensions for Industrial Models (Dimensions in inches. Multiply by 25.4 to obtain millimeters.) Ordering Information for Industrial Models 12 Typical Part No. ‰ 21 12 D 4 N B 1. Basic Series: 21 = 2100 Miniature electropneumatic timing relay 2. Operation: 1 = On-delay 2 = Off-delay 3. Contact Arrangement: 2 = DPDT (2 form C) 4. Operating Voltage: A = AC D = DC 5. Physical Characteristics: Code Enclosure Adjustment Connector Mounting 4 = Unsealed External Knob Octal Plug Chassis Mount 5 = Unsealed Internal Key Octal Plug Chassis Mount 9 = Unsealed Internal Key Solder Hook Panel Mount Plate 6. Coil Voltage: M = 12VDC N = 28VDC P = 48VDC R = 110VDC Y = 125VDC S = 120VAC, 50/60 Hz. T = 240VAC, 60 Hz. 7. Timing Range: A = .03 to .1 sec. C = .15 to 1.0 sec. E = .75 to 10.0 sec. H = 5.0 to 120.0 sec. K = 1.5 to 30.0 cycles B = .1 to .3 sec. D = .375 to 3.0 sec. F = 1.0 to 30.0 sec. J = 5.0 to 180.0 sec. L = 3.0 to 120.0 cycles Our authorized distributors are more likely to maintain the following items in stock for immediate delivery. None at present. 12–5 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays AGASTAT 2100 Series, Miniature Electropneumatic Timing Relay (Continued) Specifications for Hermetically Sealed Models Dielectric — Withstands 1,000 Volts RMS at 60 Hz between non-con nect ed terminals. Other — AGASTAT Miniature Timing Relays also conform to ap pli ca ble requirements covering: Moisture Ozone Humidity Sunshine Sand/Dust Acoustic Noise Salt Spray Prolonged Storage Outline Dimensions for Hermetically Sealed Models (In inches. Multiply by 25.4 for millimeters.) 8 Pin Solder Hook or MS/AN 8 Pin Solder Connector Hook or MS/AN Connector Panel Mount Panel Mount -H1, -H3 -9 Octal Plug (with Internal Octal Plug (with Internal Adjustment or External Adjustment or External Adjustment Knob) Adjustment Knob) Chassis Mount Chassis Mount -H2 -4, -5 12–6 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays AGASTAT 2100 Series, Miniature Electropneumatic Timing Relay (Continued) Ordering Information for Hermetically Sealed & Unsealed Models Typical Part No. ‰ 21 12 D H1 NB 1. Basic Series: 21 = 2100 Miniature electropneumatic timing relay 2. Operation: 1 = On-delay 2 = Off-delay 3. Contact Arrangement: 2 = DPDT (2 form C) 4. Operating Voltage: A = AC D = DC 5. Physical Characteristics: Code Enclosure Adjustment Connector Mounting H1 = Hermetically Sealed External Screw Solder Hook Panel Mount Plate H2 = Hermetically Sealed External Screw Octal Plug Chassis Mount H3 = Hermetically Sealed External Screw “AN” Connector Panel Mount Plate 4 = Unsealed External Knob Octal Plug Chassis Mount 5 = Unsealed Internal Key Octal Plug Chassis Mount 9 = Unsealed Internal Key Solder Hook Panel Mount Plate 6. Coil Voltage: M = 12VDC N = 28VDC P = 48VDC R = 110VDC Y = 125VDC S = 120VAC, 50/60 Hz. T = 240VAC, 60 Hz. U = 115VAC, 400 Hz. 7. Timing Range: A = .03 to .1 sec. C = .15 to 1.0 sec. E = .75 to 10.0 sec. H = 5.0 to 120.0 sec. K = 1.5 to 30.0 cycles B = .1 to .3 sec. D = .375 to 3.0 sec. F = 1.0 to 30.0 sec. J = 5.0 to 180.0 sec. L = 3.0 to 120.0 cycles Our authorized distributors are more likely to maintain the following items in stock for immediate delivery. None at present. 12 12–7 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay Design & Construction On-delay model 7012 (delay on pickup) There are three main components of Applying voltage to the coil (L1-L2) for Series 7000 Timing Relays: at least 50 msec starts a time delay Timing Head cir cu lates air through a lasting for the preset time. During this vari able length to provide linearly pe ri od the nor mal ly closed con tacts adjustable timing. Pat ent ed design pro- (3-5 and 4-6) re main closed. At the end vides easy ad just ment and long service of the delay period the norm al ly closed life under severe operating con di tions. contacts break and the normally open Precision-Wound Potted Coil contacts (1-5 and 2-6) make. The Total sealing without external leads con tacts re main in this trans ferred eliminates moisture prob lems, gives po si tion until the coil is deenergized, maximum insulation value. at which time the switch ret urns to its Snap-Action Switch Assembly — orig i nal position. custom-de signed over-center mecha- De-energizing the coil, either dur ing or Product Facts nism provides snap action. Standard after the de lay pe ri od, will re cy cle the switches are DPDT arrangement. unit within 50 msec. n Available in on-delay, true Each of these subassemblies forms off-delay, and on/off-delay It will then pro vide a full delay period self-con tained mod ules assembled at upon re-energization, re gard less of how n Timing from 0.1 seconds to the factory with the other two to afford often the coil voltage is in ter rupt ed a wide choice of operating types, coil 60 minutes, in linear before the unit has been per mit ted to voltages, and timing ranges. increments "time-out" to its full delay setting. The squared design with front terminals n Oversize adjustment knobs, and rear mounting permits the grouping of serrated with high-resolution Series 7000 units side-by-side in mini- markings visible from all mum panel space. Auxiliary switch es may Off-delay model 7022 (delay on dropout) angles makes the timer be add ed in the base of the unit, without easy to set timers affecting the overall width or depth. Applying voltage to the coil (for at least 50 msec) will transfer the switch, n Inherent transient immunity Operation breaking the nor mal ly closed contacts Two basic operating types are available. n Standard voltages from (1-5 and 2-6), and mak ing the nor mal ly “On-De lay” mod els provide a delay period 6-550VAC and 12-550VDC open contacts (3-5 and 4-6). Contacts on energization, at the end of which the (special voltages available) remain in this transferred position as long switch transfers the load from one set of as the coil is en er gized. The time delay n Available in 2-pole or 4-pole contacts to an oth er. De-energizing the be gins immediately upon de-energization. models unit dur ing the delay period im me di ate ly At the end of the de lay period the switch recycles the unit, ready ing it for another n Numerous enclosure returns to its normal po si tion. full de lay period on re-energization. options — explosion proof, Re-energizing the coil during the delay In "Off-Delay" models the switch trans- dust tight, watertight, period will im me di ate ly return the timing fers the load im me di ate ly upon energiza- hermetically-sealed, mechanism to a point where it will pro- tion and the delay period does not be gin vide a full delay period upon sub se quent NEMA 1 until the unit is de-energized. At the end de-energization. The switch remains in of the delay period the switch returns to n Auxiliary timed and the transferred position. its original po si tion. Re- en er giz ing the instantaneous switches can unit during the delay period im me di ate ly be added for greater resets the timing, ready ing it for another switching flexibility full delay period on de-energization. No power is required during the timing n Many mounting options — period, providing a true off delay. Surface mount, Panel In addition to these basic operating types, mount, Octal plug-in “Double-Head” models offer sequential mounting delays on pull-in and drop-out in one n Options: quick-connect unit. With the addition of auxiliary terminals, dial stops, and switches the basic models provide two- step timing. transient pro tec tion module Note: Seismic & radiation tested n Easy-to-reach screw E7000 models are available. terminals, all on the face of Consult factory for detailed the unit, clearly identified in for ma tion. n Modular assembly — timing head, coil as sem bly and switchblock are all individual modules, with switches field-replaceable Note: 7032 types and certain models with accessories are not agency approved. n File E15631, Users should thoroughly review the technical data before selecting a product part File LR29186 number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements R for a given application. R Consult factory for ordering information. 12–8 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay (Continued) 4. De-energizing coil resets both 4. Main switch transfers after total Auxiliary Switch Options for Auxiliary Switch Options switches instantly. First delay is preset delay. First delay is independ- On-Delay To increase the versatility of the basic independently adjustable, up to 30% ently adjustable, up to 30% of over all timer mod els, aux il ia ry switches may be Instant Transfer (Auxiliary Switch of over all delay. (Rec om mend ed delay. (Rec om mend ed maximum added to either on-delay or off-delay Code L, max i mum of 2 per relay.) maximum 100 sec onds.) 100 sec onds.) types. They switch additional circuits, 1. Energizing coil begins time delay and Instant Transfer (Auxiliary Switch pro vide two-step timing action, or fur- Auxiliary Switch Options for transfers aux il ia ry switch. Code L, max i mum of 1 per relay.) nish electrical in ter lock for sus tained Off-Delay 2. Main switch transfers after total coil energization from a momentary 1. Energizing coil transfers main and preset delay. In these models the same auxiliary impulse, depending on the type selected auxiliary switch es in stant ly. switch provides ei ther two-step timing or 3. De-energizing coil resets both and its ad just ment. They are installed at 2. De-energizing coil resets auxiliary instant transfer action, de pend ing on the switches instantly. the factory. All aux il ia ry switches are switch and be gins time delay. ad just ment of the actuator. Auxiliary switch is nonadjustable. SPDT with UL listings of 10A @ 125, 3. Main switch transfers after total Two-Step Timing (Auxiliary Switch 250, or 480 VAC. A maximum of one Two-Step Timing (Auxiliary Switch preset delay. Code T, max i mum of 1 per relay.) Code T or two Code L auxiliary switch es Code T, max i mum of 1 per relay.) Auxiliary switch is factory adjusted to 1. Energizing coil transfers main and may be added to each relay. The L or LL 1. Energizing coil begins time delay. give instant trans fer op er a tion. Two-step auxiliary switch es in stant ly. switch is available with on-delay relays 2. After first delay auxiliary switch timing may be set at the factory to cus- only. The T switch is available with both 2. De-energizing coil begins time delay. transfers. tomer specification up to a 3:2 ratio. the on-delay and off-de lay relays. 3. After first delay auxiliary switch 3. Main switch transfers after total transfers. preset delay. On-delay, Off-delay Model 7032 (Double Head) The Double Head model provides delayed switch trans fer on energization of its coil, and de layed resetting upon coil de- energization. Each delay period is in de pen dent ly adjustable. In new circuit designs or the improvement of ex ist ing con trols now using two or more conventional tim ers, the Double Head unit offers distinct advantages. Its compact design saves panel space, while the simplified wiring reduces costly in ter con nec tion. 12 On-delay Model 7014, Off-delay Model 7024 With the addition of an extra switch block at the bot tom of the basic unit, this version of the Series 7000 offers four pole switch capacity with simul taneous tim ing or two-step timing. The two-step operation is achieved by factory adjustment to your specifications. For two-step operation, a maximum timing ratio be tween upper and lower switches of 3:2 is rec om mend ed. Once ad- just ed at the factory, this ratio remains con stant regardless of changes in dial settings. (Ex: If up per switch transfer is set on dial at 60 sec., minimum time on lower switch should be 40 sec.) This Series 7000 unit offers many of the per for m ance fea- tures found in basic models — voltage ranges, timing and switch capacities. Four pole models add approximately 1-1/4" to the max i- mum height of the basic model, approximately 1/8" to the depth. They are designed for vertical op er a tion only. 12–9 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay (Continued) Surge/Transient Protection Option The Surge/Transient Protection Option pro tects elec tron ic Product Facts con trol cir cuits from tran sients and surg es which are n Protect electronic control gen er at ed when the timer coil is ac ti vat ed. The de vice is not circuits from voltage po lar i ty sen si tive and permits the user to ini tiate, delay, transients generated by the sequence and pro gram equip ment ac tions over a wide range timer coil of ap pli ca tions under the most se vere operating con di tions. The varistor will not affect the operating characteristics of n Fast response to the rapidly the 7000 Tim er. The varistor has bilateral and symmetrical rising back E.M.F. voltage and current characteristics. n High performance clamping voltage char ac ter is tics n UL recognized, (except varistor and coil together). Transient Suppressor Option "V" n Timer NOT polarity sensitive Timing Specifications (All values shown are at nominal voltage and 25°C unless otherwise specified) Operating Modes — Operating Voltage Coil Data (for DPDT) Model 7012/7014 — On-delay (delay on pick-up). Operating* Operating Model 7022/7024 — Off-delay (delay on drop-out). Coil Code Rated Voltage Rated Voltage Part # Letter Voltage Range Volt age Range Model 7032 — On-delay, off-delay (double head). @ 60Hz @50Hz Timing Adjustment — Timing is set by simply turning the dial to the desired time 7000 A 120 102-132 110 93.5-121 value. In the zone of approximately 25° sep a rat ing the high and low end of timing B 240 204-264 220 187-242 ranges A,D,E, and K, in stan ta neous operation (no time delay) will occur. All other C 480 408-528 ranges produce an infinite time de lay when the dial is set in this zone. D 550 468-605 Models 7014 and 7032 are available with letter dials only. The upper end of the time E 24 20.5-26.5 ranges in these models may be twice the values shown. AC F 127 108-140 Linear Timing Ranges — G 240 204-264 Models 7012, Models 7014, Code H 12 10.2-13.2 7022, 7024 7032 I6 5.1-6.6 A .1 to 1 Sec. .2 to 2 Sec. J 208 178-229 B .5 to 5 Sec. .7 to 7 Sec. Dual Voltage Coil C 1.5 to 15 Sec 2 to 20 Sec. K (Combines A&B) D 5 to 50 Sec. 10 to 100 Sec. Special AC Coils E 20 to 200 Sec. 30 to 300 Sec. L (L1, L2, etc.) F 1 to 10 Min. 1.5 to 15 Min. 7010 M 28 22.4-30.8 H 3 to 30 Min. 3 to 30 Min. N 48 38.4-52.8 I 6 to 60 Min. Not Avail. O 24 19.2-26.4 J 3 to 120 Cyc. Not Avail. P 125 100-137.5 K 1 to 300 Sec. Not Avail. Q 12 9.6-13.2 R 60 48-66 Repeat Accuracy — DC S 250 200-275 For delays of 200 seconds or less: 7012*, 7022, 7024: ±5% T 550 440-605 7014*: ±10% U 16 12.8-17.6 7032: ±15% V 32 25.8-35.2 For delays greater than 200 seconds: 7012*, 7022, 7014*, 7024: ±10% W 96 76.8-105.6 7032: ±15% Y6 4.8-6.6 * The first time delay afforded by Model 7012 with H (3 to 30 min.) and I (6 to 60 Z 220 176-242 min.) time ranges or Model 7014 with H time range will be approx. 15% long er than Special DC Coils sub se quent delays due to coil temperature rise. X (X1, X2, etc.) Reset Time — 50 msec. (except model 7032) *Four pole Models: Operational voltage range 90% to 110% for AC units; 85% to Relay Release Time — 50 msec. for on-delay models (7012/7014) 110% for DC units. Relay Operate Time — 50 msec. for off-delay models (7022/7024) See next page for more coil data. 12–10 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay (Continued) Timing Specifications (All values shown are at nominal voltage and 25°C unless otherwise specified) Minimum operating voltages are based on ver ti cal ly mount ed 7012 units. 7012 hor i- Dielectric — Withstands 1500 volts RMS 60Hz between terminals and ground. zon tal ly mounted or 7022 ver ti cal ly or horizontally mounted units will operate sat is- 1,000 volts RMS 60 Hz between non-con nect ed terminals. For dielectric specification fac to ri ly at minimum voltages approximately 5% low er than those list ed. on hermetically sealed mod els consult factory. AC units drop out at approximately 50% of rated voltage. DC units drop out at ap prox- Insulation Resistance — 500 Megohms with 500VDC applied. i mate ly 10% of rated voltage. Temperature Range — All units may be operated on intermittent duty cy cles at voltages 10% above the listed Operating — -20°F to +165°F (-29°C to 74°C) maximums (in ter mit tent duty - maximum 50% duty cycle and 30 minutes “on” time.) Storage — -67°F to +165°F (-55°C to 74°C) Surge/Transient Protection Option Characteristics (DC Timers Only) Temperature Variation — Using a fixed time delay which was set and measured when the ambient temperature was 77°F (25°C), the maximum observed shift in the Coil Voltage Max Excess Max De-energization Nominal (DC) Energy Capacity (Joule) Tran sient Voltage average of three con sec u tive time de lays was -20% at -20°F (-29°C) and +20% at 165°F (74°C). 12 V 0.4 J 48 V 24 V 1.8 J 93 V Mounting/Terminals — Normal mounting of the basic unit is in a vertical po si tion, from the back of the panel. All units are tested for vertical operation. Basic 28 V 1.8 J 93 V models (7012, 7022) may also be horizontally mount ed, and will be adjusted ac cord- 32 V 2.5 J 135 V ing ly when Accessory Y1 is spec i fied in your order. 48 V 3.57 J 145 V Standard screw terminals (8-32 truss head screws sup plied) are located on the front of 60 V 6 J 250 V the unit, with per ma nent sche mat ic markings. Barrier isolation is de signed to ac com- 96 V 10 J 340 V mo date spade or ring tongue ter mi nals, with spacing to meet all industrial control 110 V 10 J 340 V spec i fi ca tions. 125 V 10 J 340 V The basic Series 7000 may also be panel mounted with the addition of a panel mount 220 V 17 J 366 V kit, X option, that includes all nec es sary hardware and faceplate. This offers the 250 V 17 J 366 V con ve nience of “out-front” adjustment, with large dial skirt knob. The faceplate and Surge Life — knob blend with ad vanced equipment and console designs, while the body of the unit Applied 100,000 times continuously with the in ter val of 10 seconds at room tempera- and its wiring are protected behind the panel. ture. Below 68 VAC: 12A; Above 68 VAC: 35A Other mounting options include plug-in styles and special configurations to meet Temperature Range — unusual installation re quire ments. Contact factory for details. Operating — -22°F to +167°F (-30°C to + 75°C) Power Consumption — Approximately 8 watts power at rated voltage . Storage — -40°F to +167°F (-40°C to +75°C) Approximate Weights — Output/Life Contact Ratings — Contact Capacity in Amps (Resistive Load) Models 7012, 7022 . . . . . . . . . . . . . . . . . . . . . . . 2 lbs. 4 ozs. Contact Min. 100,000 Min. 1,000,000 7014, 7024 . . . . . . . . . . . . . . . . . . . . . . 2 lbs. 10 ozs. Voltage Operations Operations 7032 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 lbs. 5 ozs. 12 30 VDC 15.0 7.0 Weight may vary slightly with coil voltage. 110 VDC 1.0 0.5 120 V 60Hz 20.0 15.0 240 V 60Hz 20.0 15.0 480 V 60Hz 12.0 10.0 10 Amps Resistive, 240 VAC 1/4 Horsepower, 120 VAC/240VAC (per pole) 15 Amps 30 VDC (per pole) 5 Amps, General Purpose, 600VAC (per pole) 12–11 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay (Continued) Outline Dimensions (Dimensions in inches) Models 7012, 7022 Models 7014, 7024 Model 7032 Panel Mount Option “X” Surge/Transient Protection Option 12–12 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay (Continued) Ordering Information Typical Part No. ‰ 70 12 A D GZ 1. Basic Series: 70 = 7000 series electropneumatic timing relay 2. Operation: 1 = On-delay 3 = On-delay, off-delay (double head) 2 = Off-delay 3. Contact Arrangement: 2 = 2PDT (2 form C) **4 = 4PDT (4 form C) 4. Coil Voltage: AC Coils DC Coils A = 120VAC, 60 Hz.; 110VAC, 50Hz. M = 28VDC B = 240VAC, 60 Hz.; 220VAC, 50Hz. N = 48VDC C = 480VAC, 60 Hz. O = 24VDC D = 550VAC, 60 Hz. P = 125VDC E = 24VAC, 60 Hz. Q = 12VDC F = 127VAC, 50 Hz. R = 60VDC G = 240VAC, 50Hz. S = 250VDC H = 12VAC, 60 Hz. T = 550VDC K = Dual voltage (combines A & B) U = 16VDC L = Special AC coils (L1, L2, etc.) V = 32VDC W = 96VDC Y = 6VDC Z = 220VDC X = Special DC coils (X1, X2, etc.) 5. Timing Range: Models 7012, 7022 & 7024 †Models 7014 & 7032 A = .1 to 1 sec. For model 7032 specify separate time B = .5 to 5 sec. range code for each head. Example: AB. C = 1.5 to 15 sec. Any two ranges may be selected. D = 5 to 50 sec. A = .2 to 2 sec. E = 20 to 200 sec. B = .7 to 7 sec. F = 1 to 10 min. C = 2 to 20 sec. H = 3 to 30 min. D = 10 to 100 sec. I = 6 to 60 min. E = 30 to 300 sec. 12 J = 3 to 120 cyc. F = 1.5 to 15 min. K = 1 to 300 sec. H = 3 to 30 min. 6. Options: A1 = Single quick-connect terminals (note 4). l2 = Tamper-proof Cap, transparent (Cannot be combined with Option X). A2 = Double quick-connect terminals (note 4). L = Auxiliary Switch, instant transfer. 7012 only (notes 2 & 6). B = Plug-in connectors (note 4). LL = Two Aux. Switches, instant transfer. On Model 7014 Factory Installed Only. (notes 2 & 6) GZ = Enclosure with bottom knockouts (note 1). M = Dust-tight Gasketing (notes 4 & 5). H2 = Hermetically sealed enclosure, 8 pin solder (notes 1 & 4). P = Octal Plug Adapter. Can be combined only with options l1,l2. M, S, X, or Y1. (note 4). H3 = Hermetically sealed enclosure, 8 pin octal (notes 1 & 4). S = Dial Stops. H4 = Hermetically sealed enclosure, 8 screw terminal block (notes 1 & 4). T = Auxiliary Switch, two-step timing (notes 2 & 6). *H6 = Hermetically sealed enclosure, 11 pin solder (notes 1 & 4). V = Transient/Surge Protection (for DC coil voltage only). *H7 = Hermetically sealed enclosure, 11 pin octal (notes 1 & 4). X = Panelmount includes hardware and adjustment for horizontal operation (note 4) *H8 = Hermetically sealed enclosure, 11 screw terminal block (notes 1 & 4). Y1 = Horizontal testing, for horizontal operation without panel mounting (note 4). l1 = Tamper-proof Cap, opaque black (Cannot be combined with Option X). Y2 = Horizontal testing, with Compensating Spring for vertical operation (note 4). Notes: 1. Cannot be combined with B, P or X Options 2. Cannot be combined with B, P or Y2 Options 3. Cannot be combined with GZ, H, l1, l2, K, W or Y1 Options 4. Not Avail. on 4-Pole Models 5. Not Available with L, T or LL options. 6. Not Available on hermetically sealed units. * Sized to accommodate one L or T Auxiliary Switch ** Not available on 7032 model. † Available with letter graduated dials only. Upper end of time range may be twice the value shown †† 120 cycles = 2 sec. Our authorized distributors are more likely to maintain the following items in stock for immediate delivery. 7012AA 7012AE 7012ACL 7012PB 7012PJ 7022AA 7022AE 7022AJ 7022PA 7012AB 7012AF 7012BC 7012PC 7012PK 7022AB 7022AF 7022AKT 7022PB 7012AC 7012AH 7012NC 7012PD 7012PKX 7022AC 7022AH 7022BC 7022PC 7012AD 7012AK 7012PA 7012PF 7012PJX 7022AD 7022AI 7022BK 7022PK 12–13 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay (Continued) Ordering Options — Can only be ordered as factory installed options (Dimensions, where shown, are in inches) A1 – Single Quick-Connect A2 – Double Quick-Connect B – Plug-In Connectors GZ – Metal En clo sure Ter mi nals Ter mi nals Use with Accessory “C” or “D” below. With knockouts for bottom connection. 3.16" W x 3.84" D x 7.63"H H – Hermetically Sealed I – Tamper-Proof Cover L – Auxiliary Switch LL – Auxiliary Switch Enclosure M – Dust tight P – Octal Plug Adapter S – Dial Stops T – Auxiliary Switch Gasket Gasket V – Transient/Surge Protection X – Panelmount Kit Mounting hardware included. Transient Protection Accessories (Not available for 7032 models) Plug-In Receptacle (Accessory C) Plug-In Receptacle (Accessory D) Screw Terminals Quick Connect Terminals Catalog No. 700137. Catalog No. 700141. For use with “B” Option. For use with “B” Option. Ordering options can only be ordered as factory installed options. 12–14 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays AGASTAT E7000 Series, Nuclear Qualified Time Delay Relays Seismic and Radiation Tested In order to satisfy the grow- Qualifying Class 1E Equip - The present E7000 Series ing need for electrical con- ment for Nuclear Power design has evolved over trol components suitable for Generating Stations) and 40 years of continual field class 1E service in nuclear IEEE Standard 344-1975 use in a wider range of power generating stations, (Seismic Qualifications for industrial applications. AGASTAT timing relays have Nuclear Power Generating On-Delay, Off-Delay and been tested for three appli- Stations). Testing was also Four-Pole versions are avail- cations. These E7000 Series referenced to ANSI/IEEE able for use with a choice electropneumatic devices C37.98 (formerly IEEE of 23 coil voltages, as well have demon strated compli- Standard 501-1978, as time delay adjustment to ance with the requirements Standard for Seismic as long as 60 minutes. of IEEE Standards 323- Testing of Relays). 1974 (Standard for Test Procedure Operate Time (milliseconds) Test Procedure Temperature Aging Hostile Environment Recycle Time (milliseconds) AGASTAT timing relay Models E7012, This test subjected the relays to a tem- Since the timing relays are intended for Time Delay (seconds) E7022, E7014 and E7024 were tested in perature of 100°C for 42 days, with per- use in auxiliary and control buildings, Repeatability (percent) accordance with the requirements of IEEE formance measured before and after and not in the reactor containment areas, Contact Bounce STD. 323-1974 (Standard for Qualifying thermal stress. a hostile environment test was per- (milliseconds at 28VDC, 1 amp) Class 1E Equipment for Nuclear Power formed in place of the Loss of Coolant Seismic Aging Contact Resistance Generating Stations), IEEE STD. 344-1975 Accident (LOCA) test. Relays were (milliohms at 28VDC, 1 amp) Sufficient interactions were performed at (Seismic Qualification for Nuclear Power subjected to combination extreme levels less than the fragility levels of the Data was measured and recorded and Generating Stations) and referenced to temperature/humidity plus under/over devices in order to satisfy the seismic used for comparison throughout the ANSI/EEE C37.98 (formerly IEEE voltage testing to prove their ability to aging requirements of IEEE STD 323- qualification test program in order to Standard 501-1978, Standard for function under adverse conditions even 1974 and IEEE STD 344-1975. detect any degradation of performance. Seismic Testing of Relays). The relays after having undergone all the previous were tested according to parameters aging simulation and seismic testing. Seismic Qualification Radiation Aging which in practice, should encompass the The devices were operated at minimum Artificially aged relays were subjected to Relays were subjected to a radiation majority of applications. Documented and maximum voltage extremes: 85 and 5 simulated seismic vibration, which veri- dosage of 2.0 x 10 Rads, which is con- data applies to timing relays which were 120 percent of rated voltage for AC fied the ability of the individual device to 12 sidered to exceed adverse plant operat- mounted on rigid test fixtures. The units, and 80 and 120 percent of rated perform its required function before, dur- ing requirements for such areas as following descriptions of the tests voltage for DC units, with temperatures ing and/or following design basis earth- auxiliary and control buildings. performed are presented in their actual ranging from 40°F to 172°F at 95 per- quakes. Relays were tested in the sequence. cent relative humidity. Cycling with Load Aging non-operating, operating and transi- The radiated units were then subjected to Baseline Performance tional modes. 27,500 operations at accelerated rate, In addition to aging tests, a series of with one set of contacts loaded to baseline tests were conducted before, 120VAC, 60Hz at 10 amps; or 125VDC and immediately after each aging at 1 amp, and the number of mechanical sequence: operations exceeding those experienced Pull-in Voltage in actual service. Drop-out Voltage Dielectric Strength at 1650V 60Hz Insulation Resistance The SRS shape (at 5 percent damping), is defined by four points: point A = 1.0 Hz and an acceleration equal to 25 percent of the Zero Period Acceleration point D = 4.0 Hz and 250 percent of the ZPA point E = 16.0 Hz and 250 percent of the ZPA point G = 33.0 Hz and a level equal to the ZPA SPECIMEN 1 & 3 (E7012 SERIES) RELAY STATE: TRANSITIONAL MODE (TD X 2) AXIS (H + V): TEST RUN NO. 41, 45, 60, 63 COMPOSITE OF FB/V-, SS/V-, SS/V+, FB/V+ X .707 DUE TO 45° INCLINATION OF TEST MACHINE. Figure 1. Response Spectrum, Transitional Mode 12–15 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays AGASTAT E7000 Series, Nuclear Qualified Time Delay Relays (Continued) Operation Two basic operating types are available: In off-delay models the switch transfers On-delay models provide a delay period the load immediately upon energization, on energization, at the end of which the and the delay period does not begin until switch transfers the load from one set of the unit is deenergized. At the end of the contacts to another. Deenergizing the delay period the switch returns to its unit during the delay period immediately original position. Reenergizing the unit recycles the unit, readying it for another during the delay period immediately full delay period on reenergization. resets the timing, readying it for another full delay period on deenergization. No power is required during the timing period. On-Delay Models, E7012 Off-Delay Models, E7022 (Delay on pick-up) (Delay on drop-out) Applying for at least 50 msec voltage Applying voltage to the coil (for at to the coil (L1-L2) starts a time delay least .050 second) will instantaneously lasting for the preset time. During this transfer the switch, breaking the normally period the normally closed contacts closed contacts (1–5 and 2–6), and (3–5 and 4–6) remain closed. At the end making the normally open contacts of the delay period the normally closed (3–5 and 4–6). Contacts remain in this contacts break and the normally open transferred position as long as the coil is contacts (1–5 and 2–6) make. The con- energized. The time delay begins imme- tacts remain in this transferred position diately upon deenergization. At the end until the coil is deenergized, at which of the delay period the switch returns to time the switch instantaneously returns its normal position. to its original position. Reenergizing the coil during the delay Deenergizing the coil, either during or period will immediately return the timing after the delay period, will recycle the mechanism to a point where it will pro- unit within .050 second. It will then vide a full delay period upon subsequent provide a full delay period upon reener- deenergization. The switch remains in gization, regardless of how often the coil the transferred position. voltage is interrupted before the unit has Four Pole Models, E7014, been permitted to “time-out” to its full E7024 delay setting. With the addition of an extra switch block at the bottom of the basic units, this version of the E7000 Series offers four pole switch capacity with simultaneous timing or two-step timing. The two-step operation is achieved by factory adjust- ment to your specifications. 12–16 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays AGASTAT E7000 Series, Nuclear Qualified Time Delay Relays (Continued) Time Delay Information Delay Setting Contact Ratings — Nuclear All units are furnished with dials in Dial graduations are provided to minimize Resistive at 125 VDC . . . . . . . . 1.0 Amp linear increments covering the range the time required to set the unit to a Resistive at 120 VAC 60 Hz. . . 10.0 Amp selected. (See “Catalog Number Code”). specific delay. Rotate the dial clockwise Contact Ratings — Non-Nuclear In addition, ranges B through K provide to increase the delay; counter-clockwise Contact Capacity in Amps non-linear adjustment from .2 second to to decrease it. (Resistive Loads) the beginning of the linear zone. The following procedure is recom- Contact Min. 100,000 mended if the unit must be set to a very Repeat Accuracy Voltage Operations precise delay value: Repeat accuracy at any fixed temperature 30VDC 15.0 1. Set dial to desired time delay. (On is defined as: 110VDC 1.0 letter-graduated units, this requires *The repeat accuracy deviation (A ) of R 120V 60Hz 20.0 an approximation of a percentage a time-delay relay is a measure of the 240V 60 Hz 20.0 value between the arrowhead “” maximum deviation in the time-delay on the dial, which provides minimum 480V 60 Hz 12.0 that will be experienced in successive time, and the letter “E,” which Four pole models add approximately operations at any particular time setting provides maximum time.) 1-1/4" to the maximum height of the of the relay and for any particular 2. Record as many time delays as basic model, approximately 1/8" to the operating voltage or current. required to establish a stable average. depth. They are designed for vertical Repeat accuracy is obtained from the 3. If the recorded average delay is operation only. following formula: shorter than the desired time, turn (T –T ) Timing Adjustment 1 2 dial slightly clockwise; if it is longer, A = ± 100 R (T + T ) 1 2 The AGASTAT E7000 Series is the first turn dial counter-clockwise. Where — electropneumatic timer to offer the ease 4. Repeat step 2 after each adjustment, T = Maximum time delay. of adjustment and resetting of a graduated 1 until required delay is recorded. T = Minimum time delay. dial head. Discrete ranges covering a 2 Because of the variety of environments total span from .1 second to 60 minutes *NEMA part ICS 2-218.02 in which time delay relays are applied, are available. (See table on page 12-20.) Repeat accuracy at any fixed temperature we recommend a re-check of the time Each has its own graduated, clearly is ± 10% of setting. delay after approximately three hours of identified dial. Timing is set by simply The first time delay afforded by units operation. If any change from the initial turning the dial to the desired time value. with H (3 to 30 minutes) and I (6 to 60 time setting is apparent, the relay should In the zone of approximately 25° sepa- minutes) time ranges may be up to 15% be reset to the desired delay. The time rating the high and low ends of timing longer than subsequent delays, due to delay accuracy should then be moni- ranges A, D, E, and K, instantaneous coil temperature rise. tored on a monthly basis for several operation (no time delay) will occur. All months, and if no substantial change in Dial position error is not included in the other ranges produce an infinite time 12 time delay has taken place, the frequency repeat accuracy specification above. delay when the dial is set in this zone. of checking may be reduced. It is recommended that this procedure be incorporated in the Operating Instructions for your equipment. 12–17 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays AGASTAT E7000 Series, Nuclear Qualified Time Delay Relays (Continued) Relay Release (Recycle) Time — Environmental Characteristics Operating Conditions Model E7012 — 50 ms max. with DC or (Qualified Life) Parameter (Normal Environment) AC coils Temperature — Coil Operating Voltage, Nominal Model E7022 — N/A Minimum — 40°F (Rated) — Contact Ratings, Continuous — Normal — 70°F - 104°F Pull-in (% of rated value) — (Resistive at 125 Vdc) — Maximum — 156°F 80% min. with DC; 85% min. with 1.0 amp with DC or AC coils AC coils Humidity (R.H. %) — (Resistive at 120 Vac, 60 Hz) — Drop-out (% of rated value) — Minimum — 10% 10.0 amp with DC or AC coils 10% approx. with DC coils; Normal — 40-60% 50% approx. with AC coils Insulation Resistance Maximum — 95% Power (Watts at rated value) — (In megohms at 500 Vdc) — Pressure — Atmospheric 8 approx. with DC or AC coils 500 min. with DC or AC coils Radiation (rads) — Relay Operate Time — Dielectric (Vrms, 60 Hz) — 5 2.0 X 10 Gamma max. Model E7012 — N/A Between Terminals and Ground — Model E7022 — 50 ms. max. with DC 1,500 with DC or AC coils or AC coils Between Non-connected Terminals — 1,000 with DC or AC coils Repeat Accuracy — ±10% with DC or AC coils Operating Conditions (Abnormal Environment) Adverse Operating Normal DBE “A” DBE “B” DBE “C” DBE “D” Specifications Temperature (°F) 70-104 40 120 145 156 Humidity (R.H. %) 40-60 10-95 10-95 10-95 10-95 Coil Operating Voltage * (% of Rated) Model E7012 (AC) 85-110 85-110 85-110 85-110 85-110 (DC) 80-110 80-110 80-110 90-110 90-110 Model E7022 (AC) 85-110 85-110 85-110 85-110 85-110 (DC) 80-110 80-110 80-110 80-110 80-110 *All coils may be operated on intermittent duty cycles at voltages 10% above listed maximums (Intermittent Duty = Maximum 50% duty cycle and 30 minutes “ON” time.) Contact ratings as listed under Approximate Weight — The date of manufacture can be found REPLACEMENT SCHEDULE the UL Component Recognition in the first four (4) digits of the serial Model E7012 and E7022 with AC Program for 100,000 operations number on the nameplate: The qualified life of this unit is Coils — 2.13 lbs. (Per pole) — 25,000 operations or 10 years First two digits indicate XX XX Model E7012 and E7022 with DC 10 Amps, resistive, 240 VAC; the year from the date of manufacture, Coils — 2.25 lbs. 1/4 horsepower, 120 VAC/240 VAC; whichever occurs first. Second two digits indicate Model E7014 and E7024 with AC 15 Amps, 30 VDC; the week. Coils — 2.43 lbs. 5 Amps, General Purpose, 600 VAC Example: Date code 8014: 80 indicates Model E7014 and E7024 with DC Coil Data — 1980; 14 indicates the week of April 2 Coils — 2.57 lbs. All units draw approximately 8 watts through 8. (Weight may vary slightly with particular power at rated voltage. coil voltage.) The operating voltage range for AC MODEL E7012PC003 Terminals — relays is 85 to 110 percent of nominal COIL 125VDC Serial 8014 – Standard screw terminals (#8 – 32 truss rated value. TIME 1.5 TO 15 SEC. head screws supplied) are located on the AC units drop-out at approximately 50% L1 L2 front of the unit, with permanent of rated voltage. schematic markings. Barrier isolation is The operating range of DC relays is 80 designed to accommodate spade or to 110 percent of nominal rated value. ring-tongue terminals with spacing to DC units drop-out at approximately 10% meet industrial control specifications. of rated voltage. Note: TE Connectivity Corporation All units may be operated on intermittent cannot recommend the use of its duty cycles (50% on/off, maximum 30 products in the containment areas of minutes on) at voltages 10% above the Nuclear Power Generating Stations. listed maximums. 12–18 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays AGASTAT E7000 Series, Nuclear Qualified Time Delay Relays (Continued) Dimensions and Mounting 12 L1 L2 M M The E7000 Series relay must A bracket for mounting the are provided in the rear of Mounting Instructions be mounted in the vertical device and the screws and the device for attaching the position. All performance lockwashers required to mounting bracket, or for specifications of these units attach it to the relay are mounting the relay directly are valid only when they are supplied with each unit. to a panel, from the rear. mounted in this manner. Four #8–32 tapped holes 12–19 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays AGASTAT E7000 Series, Nuclear Qualified Time Delay Relays (Continued) Ordering Information Catalog Number Code E 70 1 2 A A **004 Nuclear AGASTAT Operation Contact Arrangement Coil Time Range Configuration Safety 7000 Series 1 – On-delay 2 – Double Pole Voltage E7012, E7022 Code Related Timing Relay 2 – Off-delay Double Throw 4 – Four Pole Double Code Code Throw A 120V 60 Hz A .1 to 1 sec. 110V 50 Hz B .5 to 5 sec. B 240V 60Hz C 1.5 to 15 sec. 220V 50Hz D 5 to 50 sec. C 480V 60Hz E 20 to 200 sec. D 550V 60Hz F 1 to 10 min. AC E 24V 60Hz H 3 to 30 min. F 127V 50Hz I 6 to 60 min. G 240V 50Hz K 1 to 300 sec. H 12V 60Hz I 6V 60Hz *E7014 J 208V 60Hz A .2 to 2 sec. B .7 to 7 sec. M 28 VDC C 2 to 20 sec. N 48 VDC D 10 to 100 sec. O 24 VDC E 30 to 300 sec. P 125 VDC F 1.5 to 15 min. Q 12 VDC H 3 to 30 min. R 60 VDC * Model E7014 is available with letter-graduated dials only. The DC S 250 VDC E7024 upper end of the time ranges in these models may be twice the T 550 VDC A .1 to 1 sec. values shown. U 16 VDC B .5 to 5 sec. ** Configuration Code V 32 VDC C 1.5 to 15 sec. The Configuration Code is a suffix to the Model Number which W 96 VDC D 5 to 50 sec. provides a means of identification. When a significant product Y 6 VDC E 20 to 200 sec. change is introduced, the Configuration code and specification Z 220 VDC F 1 to 10 min. sheets will be revised. (001, 002, 003, 004, etc.). H 3 to 30 min. I 6 to 60 min. K 1 to 300 sec. Relay Classifications Control Code Summary Configuration Control Product Code – 001 Code – 002 Code – 003 Code – 004 E7000 Contains all materials present in Sept. 1981 — Elastomer gasket March 1989 — Paint change to Dec. 1991 — Paint change to original qualification testing. material change to improve timing head portion of relay. timing head portion of relay. thermal aging properties. New paint: Sherwin-Williams New paint: Prime coatings Material changed for Buna-N or E61YC37 primer and PPG No. 28032 Enamel. No primer Neoprene to Neoprene only. W48392 silver polyester top is used with this finish. coat. Configuration Code: The Configuration code is a suffix to the Model Number which provides a means of identification. When a significant product change is introduced, the Configuration code and specification sheets will be revised. (001, 002, 003, 004, etc.) PPG is a trademark of PPG Industries. Sherwin-Williams is a trademark of The Sherwin-Williams Company. 12–20 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays AGASTAT EGP/EML/ETR Series, Nuclear Qualified Control Relays Seismic and Radiation Tested In order to satisfy the qualifying Class 1E Equip - The design of Series EGP, need for electrical control ment for Nuclear Power EML and ETR control relays components suitable for Generating Stations) and has evolved over 20 years class 1E service in nuclear IEEE Standard 344-1975 of continual use in a wide power generating stations, (Seismic Qualification for range of industrial AGASTAT control relays have Nuclear Power Generating applications. Control Relay, been tested for these appli- Stations). Testing was also Magnetic Latch and Timing cations. Series EGP, EML referenced to ANSI/IEEE Relay versions are available and ETR have demonstrated C37.98 (formerly IEEE for use with a choice of compliance with the require- Standard 501-1978, coil voltages, as well as an ments of IEEE Standards Standard for Seismic internal fixed or adjustable 323-1974 (Standard for Testing of Relays). potentiometer in the Series ETR time delay version. Test Procedure Recycle Time (milliseconds) Test Procedure Temperature Aging Hostile Environment Time Delay (seconds) Series ETR AGASTAT control relay Series EGP, EML This test subjected the relays to a tem- Since the timing relays are intended for } Repeatability (percent) only and ETR were tested in accordance with perature of 100°C for 42 days, with per- use in auxiliary and control buildings, Contact Bounce the requirements of IEEE STD. 323-1974 formance measured before and after and not in the reactor containment areas, (milliseconds at 28VDC, 1 amp) (Standard for Qualifying Class 1E thermal stress. a hostile environment test was per- Contact Resistance Equipment for Nuclear Power Generating formed in place of the Loss of Coolant Seismic Aging (milliohms at 28VDC, 1 amp) Stations), IEEE STD. 344-1975 (Seismic Accident (LOCA) test. Relays were Sufficient interactions were performed at Data was measured and recorded and Qualification for Nuclear Power subjected to combination extreme levels less than the fragility levels of the used for comparison throughout the Generating Stations) and referenced to temperature/humidity plus under/over devices in order to satisfy the seismic qualification test program in order to ANSI/IEEE C37.98 (formerly IEEE voltage testing to prove their ability to aging requirements of IEEE STD 323- detect any degradation of performance. Standard 501-1978, Standard for function under adverse conditions even 1974 and IEEE STD 344-1975. Seismic Testing of Relays). The relays after having undergone all the previous Radiation Aging were tested according to parameters aging simulation and seismic testing. Seismic Qualification Relays were subjected to a radiation which in practice, should encompass the The devices were operated at minimum 5 Artificially aged relays were subjected to dosage of 2.0 x 10 Rads, which is con- majority of applications. Documented and maximum voltage extremes: 85 and simulated seismic vibration, which veri- sidered to exceed adverse plant operat- data applies to relays which were 120 percent of rated voltage for AC fied the ability of the individual device to 12 ing requirements for such areas as mounted on rigid test fixtures. The units, and 80 and 120 percent of rated perform its required function before, dur- auxiliary and control buildings. following descriptions of the tests voltage for DC units, with temperatures ing and/or following design basis earth- performed are presented in their actual ranging from 40°F to 172°F at 95 Cycling with Load Aging quakes. Relays were tested in the sequence. percent relative humidity. The radiated units were then subjected to non-operating, operating and transi- 27,500 operations at accelerated rate, Baseline Performance tional modes. with one set of contacts loaded to In addition to aging tests, a series of 120VAC, 60Hz at 10 amps; or 125VDC baseline tests were conducted before, at 1 amp, and the number of mechanical and immediately after each aging operations exceeding those experienced sequence: in actual service. Pull-in Voltage Drop-out Voltage Dielectric Strength at 1650V 60Hz Insulation Resistance Operate Time (milliseconds) The SRS shape (at 5 percent damping), is defined by four points: point A = 1.0 Hz and an acceleration equal to 25 percent of the Zero Period Acceleration (ZPA) point D = 4.0 Hz and 250 percent of the ZPA point E = 16.0 Hz and 250 percent of the ZPA point G = 33.0 Hz and a level equal to the ZPA Specimen 13, 15 & 16 (EGP Series) Relay State: Non-Operate Mode (De-ener.) Test Run No. 318, 319, (205-206), (198-199) Axis (H + V): Composite of FB/V-, SS/V, FB/V+ X .707 Due to 45° inclination of test machine. Additional Seismic Response Curves are available on request. Relay State: Non-Operate Mode (De-ener.) Test Run No. 318, 319, (205-206), (198-199) Figure 1. Model EGP, Response Spectrum, Non-Operate Mode 12–21 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays AGASTAT EGP/EML/ETR Series, Nuclear Qualified Control Relays (Continued) Operation Series EGP The ML Relay is not symmetrical due R-C Values Power Relay to its three coil connections. RC Nominal Voltage Ohms Applying a voltage to the coil (B1-B4) The relays are normally delivered Watts UF VDC VDC ±5% for more than 50 msec energizes the polarized so that terminal B4 carries 12 62 2 5000 15 coil and instantaneously transfers the the negative voltage. To reverse the 24 240 2 2000 50 switch, breaking the normally closed polarity, a deenergize/energize cycle 48 1000 2 500 100 contacts (M1-R1, M2-R2, M3-R3, M4- should be carried out using a voltage 125 6200 2 150 150 R4) and making the normally open 50% greater than the normal rating. contacts (M1-T1, M2-T2, M3-T3, M4- Series ETR T4). The contacts remain in this trans- M1 R1 R3 M3 Time Delay Relay ferred position until the coil is (Delay on Energization) deenergized, at which time the switch B1 T3 instantaneously returns the contacts to T1 B3 Applying a voltage to the input their original position. terminals (B1-B4) for more than 50 msec starts a time delay lasting for the preset time period. During this period the normally closed contacts (Four B2 T4 T2 B4 M-R sets) remain closed. At the end of the delay period, the normally closed contacts break and the normally open M2 R2 R4 M4 contacts (Four M-T sets) make. The contacts remain in this position until Continuous Duty Wiring the relay is deenergized, at which time Since the double wound coil does not the contacts instantaneously return to have a continuous duty rating, voltage their normal position. Deenergizing the pulses to the coils should not exceed relay, either during or after the delay a ratio of 40% on, to 60% off, with period will recycle the unit within maximum power-on periods not to .075 second. It will then provide a Series EML exceed 10 minutes. full delay period upon reenergization, Magnetic Latch regardless of how often the voltage is If continuous energizing only is Application of a voltage to the latching interrupted before the unit has been available, a resistor/capacitor network input (B1-B4) will cause the relay to permitted to “time-out” to its full delay should be connected as shown below. latch in (Make the N.O. Contacts, setting. In this case the shortest time between break the N.C. Contacts). When this two operations must not be less than voltage is removed, the relay will 5 seconds. remain in this “Latched” condition. The relay will always assume the Application of a voltage to the un- energized position in the event of latching input (B3-B4) will cause the both windings being energized relay to dropout (Break the N.O. simultaneously. Contacts, make the N.C. Contacts). When this voltage is removed, the It is advisable not to put another load relay will remain in this “Unlatched” in parallel with the windings of the condition. ML relay. ML Series Relay for DC Operation with a Resistor/Capacitor Network Wiring Diagram (Wiring and Connections) The ML relay has three terminals for the windings: latching winding between ter- minals B1 and B4, un-latching winding between terminals B3 and B4. 12–22 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays AGASTAT EGP/EML/ETR Series, Nuclear Qualified Control Relays (Continued) The date of manufacture can be found Specifications in the first four (4) digits of the serial Contact Ratings — number on the nameplate: Series EGP/EML/ETR — First two digits indicate XX XX Contact Capacity in Amperes the year (Resistive) Second two digits indicate Contact Min. 1,000,000 Voltage Operations the week. 24 Vdc 10.0 Amps Example: In the date code 7814 below: 125 Vdc 1.0 Amp “78” indicates the year 1978; “14” indicates the 14th week 120 Vac, 60 Hz 10.0 Amps (or April 3 through April 7). 240 Vac, 60 Hz 7.5 Amps Contact Ratings, UL — Series EGP/EML Only — Model Contact ratings as Listed under Coil 125 VDC the Underwriters Laboratory Serial 78140028 Component Recognition Program. (Two poles per load): Note: TE Corporation does not recom- 1/3 Horsepower, 120 Vac mend the use of its products in the 10 Amps, General Purpose, 240 Vac containment areas of Nuclear Power 120 Vdc, 1.0 Amp Generating Stations. Mechanical Life — Series EGP/EML/ETR — 25,000 mechanical operations Approximate Weight — Series EGP/EML/ETR — 1 lb. Transient Protection — Series ETR Only — A 1500 volt transient of less than 100 microseconds, or 1000 volts of less than 1 millisecond will not affect timing accuracy Timing Adjustment — Series ETR Only — 12 Internal Fixed Internal Potentiometer Time Ranges — Series ETR Only — A — .15 to 3 sec. B — .55 to 15 sec. C — 1 to 30 sec. D — 2 to 60 sec. E — 4 to 120 sec. G — 10 to 300 sec. I — 2 to 60 min. REPLACEMENT SCHEDULE N — 1 to 30 min. Series EGP/EML/ETR Repeat Accuracy — The qualified life of these relays Series ETR Only — is 25,000 electrical operations The repeat accuracy deviation (A ) of a R or 10 years from the date of time-delay relay is a measure of the manufacture, whichever maximum deviation in the time-delay that will be experienced in five successive occurs first. operations at any particular time setting of the relay and over the operating voltage and temperature range specified. Repeat accuracy is obtained from the following formula: (T - T ) 1 2 A = ± 100 R (T + T ) 1 2 Where — T = Maximum Time Delay 1 T = Minimum Time Delay 2 12–23 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays AGASTAT EGP/EML/ETR Series, Nuclear Qualified Control Relays (Continued) Operating Characteristics Environmental Conditions (Qualified Life) — Series EGP/EML/ETR Parameter Min. Normal Max. Temperature (°F) 40 70-104 156 Humidity (R.H. %) 10 40-60 95 Pressure — Atmospheric — 5 Radiation (rads) —— 2.0 x 10 (Gamma) Operating Conditions, Normal Environment – Series EGP/EML/ETR Normal Operating Specifications With DC Coils With AC Coils EGP EML ETR EGP ETR Coil Operating Voltage, Nominal (rated)* As Spec. As Spec. As Spec. As Spec. As Spec. Pull-in (% of rated value) 80% Min. 85% Min. 80% Min. 85% Min. 85% Min. Drop-out (% of rated value) 5-45% 85% Min. 5-45% 5-45% 5-50% Continuous (% of rated value) 110% Max. N/A 110% Max. 110% Max. 110% Max. Power (Watts at rated value) Pull-in 6 Apprx. 15 Apprx. 6 Apprx. 6 Apprx. 6 Apprx. Drop-out N/A 13 Apprx. N/A N/A N/A Relay Operate Time 30 ms Max. 25 ms Max. N/A 35 ms Max. N/A With min. latch pulse of 30 ms. Relay Release (Recycle) Time 25 ms Max. 20 ms Max. 75 ms Max. 85 ms Max. 75 ms Max. With min. latch pulse of 30 ms. Contact Ratings, Continuous Resistive at 125 vdc 1.0 amp. 1.0 amp. 1.0 amp. 1.0 amp. 1.0 amp. Resistive at 120 vac, 60 Hz 10.0 amp. 10.0 amp. 10.0 amp. 10.0 amp. 10.0 amp. Insulation Resistance (In megohms at 500 vdc) 500 Min. 500 Min. 500 Min. 500 Min. 500 Min. Dielectric (vrms, 60 Hz) Between Terminals and Ground 1,500 1,500 1,500 1,500 1,500 Between Non-connected Terminals 1,500 1,500 1,500 1,500 1,500 Repeat Accuracy N/A N/A ±5% N/A ±5% Operating Conditions, Abnormal Environment – Series EGP/EML Adverse Operating Specifications Normal DB “A” DB “B” DB “C” DB “D” Temperature (°F) 70-104 40 120 145 156 Humidity (R.H. %) 40-60 10-95 10-95 10-95 10-95 Coil Operating Voltage (% of rated)* AC (Series EGP only) 85-110 85-110 85-110 85-110 85-110 DC (Series EGP only) 80-110 80-110 80-110 80-110 80-110 DC (Series EML only) 85-110 85-110 85-110 85-110 85-110 Relay Operate Time (ms) AC (Series EGP only) 35 Max. 35 Max. 35 Max. 35 Max. 35 Max. DC (Series EGP, Series EML) 30 Max. 25 Max. 37 Max. 40 Max. 40 Max. Operating Conditions, Abnormal Environment – Series ETR Adverse Operating Specifications With DC Coils With AC Coils Coil Operating Voltage (rated)* As Spec. As Spec. Pull-in (% of rated value) 80% Min. 85% Min. Continuous (% of rated value) 110% Max. 110% Max. Drop-out (% of rated value) 5-45% 5-50% Power (Watts at rated value) 6 Apprx. 6 Apprx. Relay Release (Recycle) Time 75 ms Max. 75 ms Max. Contact Ratings, Continuous Resistive at 125 vdc 1.0 amp. 1.0 amp. Resistive at 120 vac, 60 Hz 10.0 amp. 10.0 amp. Repeat Accuracy ±10% ±10% *All coils may be operated on intermittent duty cycles at voltages 10% above listed maximums (Intermittent Duty = Maximum 50% duty cycle and 30 minutes “ON” time.) 12–24 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays AGASTAT EGP/EML/ETR Series, Nuclear Qualified Control Relays (Continued) Dimensions and Mounting 12 Series EGP, EML and ETR AGASTAT control relays must be mounted in the horizontal position; performance specifications of these units are valid only when they are mounted as indicated in either of the above drawings. All dimensions in inches. 12–25 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays AGASTAT EGP/EML/ETR Series, Nuclear Qualified Control Relays (Continued) Ordering Information Catalog Number Code — Series EGP and EML E GP A 004 Nuclear AGASTAT Coil Configuration Safety Control Voltage Code* Related Relay Model Code Code Code Code 004 E GP – Power A – 12 VDC Relay B – 24 VDC ML – Magnetic C – 48 VDC DC Latch D – 125 VDC E – 110 VDC F – 250 VDC (Series EGP Only) G – 24 VAC 60 Hz (Series EGP Only) H – 48 VAC 60 Hz (Series EGP Only) AC I – 120 VAC 60 Hz (Series EGP Only) J – 220 VAC 60 Hz (Series EGP Only) * Configuration Code The Configuration Code is a suffix to the Model Number which provides a means of identification. When a significant product change is introduced, the Configuration code and specification sheets will be revised. E TR14 B 1 A **004 Nuclear AGASTAT Operating Timing Time Configuration Safety Control Voltage Adjustment Range Code Related Relay Model Code Code Code Code Code Code B – 24 VDC 1 – Internal A – .15 to 3 sec. 004 DC E TR14 – Time D – 125 VDC Fixed B – .55 to 15 sec. Delay 3 – Internal C – 1 to 30 sec. Relay AC I – 120 VAC 60Hz Potentiometer D – 2 to 60 sec. (Delay E – 4 to 120 sec. on G – 10 to 300 sec. Pull-in) I – 2 to 60 min. N – 1 to 30 min. * Configuration Code The Configuration Code is a suffix to the Model Number which provides a means of identification. When a significant product change is introduced, the Configuration code and specification sheets will be revised. 12–26 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays AGASTAT EGP/EML/ETR Series, Nuclear Qualified Control Relays (Continued) Relay Classifications Control Code Summary Configuration Control Product Code – 001 Code – 002 Code – 003 Code – 004 EGP Contains all materials present in Nov. 1981 — Material change Dec. 1987 — Material change Dec. 1995 — Material change original qualification testing. to coil wrapping tape and lead on leaf spring from nickel on bobbin from Nylon wire insulation to improve copper to beryllium copper. ZYTEL 101 to RYNITE FR530. thermal life. Material change on base from Melamine Phenolic to GRILON PMV-5HV0. EML Contains all materials present in Nov. 1981 — Material change Dec. 1987 — Material change Dec. 1995 — Material change original qualification testing. to coil wrapping tape and lead on leaf spring from nickel on bobbin from Nylon wire insulation to improve copper to beryllium copper. ZYTEL 101 to RYNITE FR530. thermal life. Material change on base from Melamine Phenolic to GRILON PMV-5HV0. ETR Contains all materials present in Nov. 1981 — Material change Dec. 1987 — Material change Dec. 1995 — Material change original qualification testing. to coil wrapping tape and lead on leaf spring from nickel on bobbin from Nylon wire insulation to improve copper to beryllium copper. ZYTEL 101 to RYNITE FR530. thermal life. Material change on base from Melamine Phenolic to GRILON PMV-5HV0. ECR0001 Contains all materials present in June 1989 — Material change original qualification testing. from NORYL N-225 std. black to NORYL SE-I-701AA black. ECR0002 Contains all materials present in June 1989 — Material change original qualification testing. from NORYL N-225 std. black to NORYL SE-I-701AA black. ECR0095 Contains all materials present in June 1989 — Material change original qualification testing. from NORYL N-225 std. black to NORYL SE-I-701AA black. ECR0133 Contains all materials present in original qualification testing. ECR0155 Contains all materials present in original qualification testing. Configuration Code: The Configuration code is a suffix to the Model Number which provides a means of identification. When a significant product change is introduced, the Configuration code and specification sheets will be revised. (001, 002, 003, 004, etc.) 12 GRILON is a trademark of EMS-Chemie AG. NORYL is a trademark of SABIC Innovative Plastics. RYNITE and ZYTEL are trademarks of E.I. du Pont de Nemours and Company. 12–27 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays AGASTAT GP/ML/TR Series, 10 Amp Control Relay, Non-latching, Latching & Timing Versions GP/ML/TR Design Features This consists of a W-shaped The absence of metal-to- mechanism, shown in metal friction, the sym met ri- Among the advances Figure 1. When the center cal design of the contact AGASTAT control relays of the W is moved vertically ar range ment and the lack offer over existing designs is the lower extremities move of heavy impacts provides a unique contact operating closer to each other as can a mechanical life of mechanism. An articulated be seen in the illustration. 100,000,000 operations. arm assembly amplifies the The center of the W mech a- movement of the solenoid For use in AC circuits, the nism is connected to the core, allowing the use of a relay is supplied with a moving core of the elec tro- short stroke coil to produce built-in rectification circuit, mag net and the two lower thus retaining the high DC an extremely wide contact points are con nect ed to the gap. The long support efficiency of the electro- moving contacts. arms used in conventional magnet. The current peak SERIES GP SERIES TR re lays are eliminated. Both Two of these mechanisms on energizing is also elimi- are placed side-by-side to nated and con se quent ly current capacity and shock/ Product Facts vi bra tion tolerance are actuate the four contacts the re lay can operate with n Occupies very small panel greatly increased, as well sets of the relay. These a re sis tance in series (e.g. space as life ex pect an cy. arms act as return springs for high voltages or for for their corresponding drop-out by shorting the n May be mounted singly, in Design/Construction con tacts. coil). The use of the rectifi- continuous rows or in AGASTAT control relays are cation circuit offers still groups The mechanical amplification operated by a moving core other ad van tag es. The of the motion of the electro- n Available with screw electromagnet whose main same model can operated magnet permits a greater terminal molded socket. gap is at the center of the at frequencies ranging from distance between the con- coil. 40 to 400 cycles. Operation n 4 SPDT contacts tacts, while the high effi- of the relay is possible even The coil provides a low ciency of the electromagnet n Magnetic blowout device with a low AC voltage. mean turn length and also provides a nominal contact option increases DC assists heat dissipation. force in excess of 100 The plastic dust cover has current carrying ability Since the maximum travel of grams on the normally open two windows to facilitate approximately ten times the elec tro mag net does not contacts. cooling and also to allow for both N.O. and N.C. provide optimum contacts direct mounting of the relay. All the contacts are posi- contacts. In both AC and move ment, an ingenious tioned well away from the DC operation, the addition amplifying device has been cover and are well ventilated of the device will normally de signed. and separated from each double the contact life, due other by insulating walls. to reduced arcing. n File E15631, File LR29186 R R Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets Figure 1 — the requirements for a given application. Illustration of Amplification This diagram illustrates am pli fi ca tion ob tained by the ar tic u lat ed op er at ing mech a nism. Note: Seismic & radiation tested EGP, EML and ETR models are available. Consult factory for detailed in for ma tion. 12–28 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays AGASTAT GP/ML/TR Series, 10 Amp Control Relay, Non-latching, Latching & Timing Versions (Continued) GP/ML Contact Data @ 25°C Arrangements — 4 Form C (4PDT) Material — Silver plated Expected Life — Mechanical — 100 million operations Electrical — See chart and graph Contact Ratings and Expected Life Power Factor Number of Current or Electrical Voltage (Amps) Time Constant Op er a tions Remarks 540 VAC 3 COS Ø = 0.5 15,000 2 contacts in series 380 VAC 15 Resistive 10,000 2 contacts in parallel 380 VAC 10 Resistive 200,000 380 VAC 3 x 3.3 COS Ø = 0.8 200,000 3hp motor 220 VAC 20 Resistive 20,000 2 contacts in parallel 220 VAC 15 COS Ø = 0.5 20,000 2 contacts in parallel 220 VAC 10 Resistive 400,000 220 VAC 3 x 6 COS Ø = 0.8 200,000 3 hp motor 220 VAC 5 1,500,000 Filament lamps 220 VAC 5 Resistive 3,000,000 220 VAC 2.5 COS Ø = 0.25 2,000,000 220 VAC 2 Resistive 15,000,000 220 VAC 1.25 Resistive 30,000,000 Load Life Curve 120 VDC 1.5 Resistive 20,000,000 with blow-out device 48 VDC 10 Resistive 1,000,000 48 VDC 1.5 5 ms 18,000,000 Initial Dielectric Strength — Coil Operating Voltage Environmental Data Between non-connected terminals — Operating Temperature Range: 0°C to DC AC, 50/60Hz 2,000V rms, 60 Hz 12 +60°C. Nominal Coil Voltage 12 24 48 125 250 24 120 220 Between non-connected terminals & Vibration: Single axis fragility curve data Minimum Pick-up relay yoke — 2,000V rms, 60 Hz are available on request at frequencies Voltage at 20°C 9 18 36 94 187 19 92 175 Initial Insulation Resistance — from 5 Hz. to 33 Hz. Minimum Pick-up Between non-connected terminals — Shock: The relay, when kept energized Voltage at 40°C 9.5 19 38 100 200 20 102 188 109 ohms at 500VDC by means of one of its own contact sets, Maximum voltage Between non-connected terminals & will withstand 40g shock load when for continuous use 13.5 27 53 143 275 27 137 245 relay yoke — 109 ohms at 500VDC operating on DC, and 150g shock load For 380VAC – Use 6800 ohms 4 watt resistor in series with 220VAC relay. Coil Data on AC. For 440VAC – Use 8200 ohms 6 watt resistor in series with 220VAC relay. Voltage — 24, 120 & 220VAC, 60 Hz; Mechanical Data Drop-out voltage is between 10% and 40% of the nominal voltages for both DC and Add series resistor for 380-440VDC; Mounting Terminals — AC (For example: in a 120 VAC unit, drop-out will occur between 12 and 48 volts.) 12, 24, 48, 125 & 250VDC 16 flat base pins. Screw terminal sockets DC relays will function with unfiltered DC from a full-wave bridge rectifier. Duty Cycle — Continuous are available. Nominal Coil Power — Wire Connection — The 16 flat pins 6VA for AC coils; 6W for DC coils. Operate Data @ 20°C are arranged in four sym met ri cal rows of There is no surge current during four pins; the pitch in both di rec tions Operate Time at Rated Voltage — operation. being .394”. Connection may be made Between energizing and opening of to the relay by soldering. Sockets are normally closed contacts — less than available with screw terminals. 18 milliseconds on AC and less than 15 milliseconds on DC. The internal wiring of the relay is also symmetrical as shown in the adjacent Release Time — figure, allowing the relay to be inserted Between energizing and closing of into the socket in either of two positions. normally open contacts — less than Ter mi nals B2 and B3 are provided as extra 35 milliseconds on AC and less than connections for special app li ca tions. 30 milliseconds on DC. Between de-energizing and opening of Weight — normally open contacts — less than 10.9 oz. (308g) approximately 70 milliseconds on AC and less than 8 milliseconds on DC. Between de-energizing and closing of normally closed contacts — less than 85 milliseconds on AC and less than 25 milliseconds on DC. 12–29 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays AGASTAT GP/ML/TR Series, 10 Amp Control Relay, Non-latching, Latching & Timing Versions (Continued) Ordering Information Typical Part No. ‰ GP IN 1. Basic Series: GP = Non-latching Control Relay ML = Magnetic Latching Control Relay 2. Coil Voltage: A = 12VDC G = 24VAC, 60 Hz. B = 24VDC I = 120VAC, 60 Hz. C = 48VDC J = 220VAC, 60 Hz. D = 125VDC F = 250VDC 3. Options: N = Magnetic Blow-out Device Q = Light to indicate coil energization (GP only. 120VAC, 125VDC, 220VAC and 250VDC voltages only.) R = Internal diode to suppress coil de-energization transient. (GP only. When used on DC unit, relay release time increases to same value as AC unit). Our authorized distributors are more likely to maintain the following items in stock for immediate delivery. GPD GPDN Outline Dimensions Wiring Diagrams (Bottom Views) 12–30 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays AGASTAT GP/ML/TR Series, 10 Amp Control Relay, Non-latching, Latching & Timing Versions (Continued) TR Series Expected Life — TR Design/Construction Timing Specifications Mechanical — 100 million operations Operating Mode — Product Facts Couples an advanced Electrical — See load/life graph On-Delay (Delay on energization) electromechanical design n 8 timing ranges Initial Dielectric Strength — Timing Adjustment — with a field-proven solid- Between terminals and case and between Internal fixed or internal potentiometer n 4 SPDT contacts state timing network, an mutually-isolated contacts — 2,000VAC Timing Ranges — ad ap ta tion of the circuit n Magnetic blowout device Initial Insulation Resistance — .15 to 3 sec. used in the AGASTAT option increases DC Between non-connected terminals — .55 to 15 sec. premium grade SSC Timer. current carrying ability 109 ohms at 500VDC 1 to 30 sec. Between non-connected terminals & approximately ten times 2 to 60 sec. This unique circuit also relay yoke — 109 ohms at 500VDC for both N.O. and N.C. 4 to 120 sec. eliminates the need for sup- contacts. In both AC and 10 to 300 sec. Coil Data ple men ta ry temperature- 1 to 30 min. DC operation, the addition compensation com po nents, Voltage — 120VAC, 50-60 Hz.; 24 & 2 to 60 min. of the device will normally 125VDC af ford ing unusual stability Accuracy — double the contact life, due over a realistically broad Transient Protection — Repeat — ±2% as fixed temperature and to reduced arcing. 1,500 volt transient of less than 100 op er at ing tem per a ture voltage microseconds, or 1,000 volts or less range. It also provides Overall — ±5% over combined rated transient pro tec tion and extremes of temperature and voltage Environmental Data protection against prema- Reset Time — 75ms. Operating Temperature Range — ture switching of the output 0°C to +50°C Contact Data @ 25°C contacts due to power Mechanical Data Arrangements — 4 Form C (4PDT) interruption during tim ing. Mounting Terminals — Nominal Rating — 10A @ 120VAC 16 flat base pins. Screw terminal sockets Contact Pressure — are available. Between movable and normally closed Weight — 11 oz. (311g) approximately. contacts — 30 g, typical. Between movable and normally open contacts — 100 g, typical. 12 Ordering Information Typical Part No. ‰ TR 14 B 1 A N 1. Basic Series: TR = Timing control relay 2. Operation: 1 = On-delay 3. Output: 4 = 4PDT (4 form C) 4. Operating Voltage: B = 24VDC D = 215VDC I = 120VAC, 50/60 Hz. 5. Timing Adjustment: 1 = Internal fixed. 3 = Internal potentiometer. 6. Timing Range: A = .15 to 3 sec. C = 1 to 30 sec. E = 4 to 120 sec. I = 2 to 60 min. Load Life Curve B = .55 to 15 sec. D = 2 to 60 sec. G = 10 to 300 sec. N = 1 to 30 min. 7. Options: N = Magnetic blow-out device. Our authorized distributors are more likely to maintain the following items in stock for immediate delivery. None at present. For Outline Dimensions see page 12-30 Wiring Diagram (Bottom View) 12–31 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays AGASTAT GP/ML/TR Series, 10 Amp Control Relay, Non-latching, Latching & Timing Versions (Continued) Accessories for GP/ML/TR Series Control Relays Front Connected Sockets Cat. No. CR0001 With captive clamp ter mi nals Cat. No. CR0002 With (#6) binding head screws Cat. No. CR0095 With (#6) screw terminals Cat. No. CR0067 With (#6) screw terminals Hold Down (Locking) Springs Cat. No. CR0069 Cat. No. CR0070 Cat. No. CR0111 For socket: CR0067 For socket: CR0095 For sockets: CR0001& CR0002 Heavy-duty Hold Down (Locking) Straps *Cat. No. CR0133 *Cat. No. CR0155 For socket: CR0001 & CR0002 For socket: CR0095 * Catalog number includes strap, strap plate and necessary brackets. Magnetic Blowout Device Extracting Handle Cat. No. CR0190 Cat. No. CR0179 Reduces arcing on the relay contacts Used to remove GP, ML and TR units when they make or break contact, either from mounting bases. upon energizing or de-energizing, resulting in less contact degra dation. Extends the life of the contact. 12–32 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays VCA Series, Single Phase, Undervoltage Relay Function Input Data Single phase undervoltage relay Voltage — 120VAC, 240VAC Power Requirement — 4W max. Sensing Specifications Transient Protection — Voltage Set-Point Adjustment — 120VAC . . . . . . . . . 30 joules Internal potentiometer (screwdriver 240VDC . . . . . . . . . 30 joules adjustable) with linear calibrated dial 120VAC . . . . . . . . . 10 joules Response Time — Depending on 120VDC . . . . . . . . . 10 joules severity of undervoltage: 0.1 - 1 sec. Environmental Data Accuracy — Repeat Accuracy — ±0.2% Temperature Range — Overall Accuracy — ±1% Storage — -40°C to +85°C Operating — -23°C to +55°C Output Data Mechanical Data Arrangement — 1 Form C (SPDT) Mounting — Panel mount with one Rating — 7A @ 250VAC; 1/6 HP @ Product Facts #8 screw 250VAC; 300VA @ 120/240VAC; 3A @ 30VDC Termination — 0.250 in (6.35) quick n Automatic reset minimizes connect terminals Expected Mechanical Life — equipment downtime 10,000,000 operations Status Indication — LED indicates n Fixed pickup point prevents normal voltage condition Expected Electrical Life — 100,000 low voltage start-up operations at rated resistive load Weight — 3.2 oz. (90.7g) approximately n Adjustable dropout Initial Dielectric Strength — point protects against Between Terminals and Case — 1,480V Between Relay Contacts and Active undervoltage operation Circuitry — 1,480V n Delayed dropout prevents nuisance tripping n Compact, inexpensive design saves space, reduces cost Ordering Information n Solid state circuitry for Part Number Operating Voltage enhanced accuracy and VCAA 120VAC 12 long life VCAB 240VAC n LED indicates normal voltage condition Authorized distributors are likely to stock the following: n File E60363 R None at present. 2.00 (50.8) .763 OUTPUT RELAY (19.4) .278 (7.06) OUTPUT RELAY .286 (7.26) UNDER 2.00 VOLTAGE (50.8) ADJUST INPUT VOLTAGE .885 .170 DIA (22.5) (4.32) .250 (6.35) X .032 (.813) ACCEPTS 1.25 Users should thoroughly review the QUICK CONNECTS #8 SCREW (31.8) technical data before selecting a product part number. It is recommended that user Outline Dimensions and Wiring Diagram also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. 12–33 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays VMA series, Single Phase, Plug-in, Undervoltage Relay Initial Dielectric Strength — Function Mechanical Data Between Terminals and Case — 1,480V Single phase undervoltage relay Mounting — Octal plug. Fits 27E122 Between Relay Contacts and Active or 27E891 (snap-on) screw terminal Sensing Specifications Circuitry — 1,480V socket. Order socket separately. Voltage Set-Point Adjustment — Input Data Enclosure — Nylon cover protects Locking potentiometer with calibrated against particles. Voltage — See ordering information. dial Status Indication — LED indicates Power Requirement — 4W max. Response Time — Standard 0.5 sec. normal voltage condition. Transient Protection — delay on dropout Weight — 6 oz. (168g) approximately. 24VAC . . . . . . . . . . 1.5 joules Accuracy — 24VDC . . . . . . . . . . 1.5 joules Repeat Accuracy — ±0.5% under fixed 48VDC . . . . . . . . . . 10 joules conditions 120VAC . . . . . . . . . 10 joules Overall Accuracy — ±1% 125VDC . . . . . . . . . 10 joules Temperature Coefficient — 240VDC . . . . . . . . . 20 joules ±0.02%/°C (Max.) Reverse Polarity Protection — Product Facts Output Data On DC models Arrangement — 2 Form C (DPDT) Duty Cycle — Continuous n Automatic reset minimizes Rating — 7A @ 250VAC; 1/6 HP @ equipment downtime Environmental Data 250VAC; 300VA @ 120/240VAC; n Fixed pickup point prevents Temperature Range — 3A @ 30VDC Storage — -30°C to +60°C low voltage start-up Expected Mechanical Life — Operating — -10°C to +55°C 10,000,000 operations n Adjustable dropout point protects against Expected Electrical Life — 100,000 operations at rated resistive load undervoltage operation n Locking potentiometer maintains selected set point n Delayed dropout prevents nuisance tripping n Plug-in mounting for easier installation Ordering Information n Built-in protection against Part Number Nominal Voltage Pick-Up (V) Drop-Out Range (V) polarity reversal VMAXEA 24VAC 21 15 to 20 n LED indicates normal VMAXAA 120VAC 104 78 to 99 voltage condition VMAXBA 240VAC 209 156 to 199 VMAXOA 24VDC 21 15 to 20 n File E60363 R VMAXNA 48VDC 42 31 to 40 VMAXPA 125VDC 109 81 to 103 Authorized distributors are likely to stock the following: None at present. Users should thoroughly review the Wiring Diagram technical data before selecting a product (Bottom View) Outline Dimensions part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. 12–34 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays SCB/SCC Series, Specification Grade Discrete Plug-in, Time Delay Relay Timing Specifications Contact Data @ 25°C Environmental Data Timing Modes — Arrangements — 2 Form C (DPDT) Temperature Range — On-Delay, Off-Delay and Interval Storage — Rating — 10A @ 28VDC or 120VAC, SCB and SCC — -40°C to +85°C Timing Ranges — 6 to 180 cycles; resistive; 1/3 HP @ 120/240VAC; Operating — 0.1 to 3 / 0.1 to 10 / 0.33 to 10 / 1 to 30 345VA. Same polarity. SCB: -30°C to +65°C; / 4 to 120 sec.; 0.33 to 10 / 1 to 30 / 2 to Expected Mechanical Life — SCC: -30°C to +50°C 60 min.; 0.33 to 10 hr. (All are +5%, – 10 million operations 0% of maximum values). Mechanical Data Expected Electrical Life — 500,000 Timing Adjustment — operations, min., at rated resistive load Mounting/Termination — Knob or fixed time (internal fixed resis- SCB — UL recognized. Optional 8- or Initial Dielectric Strength — tor) — all models; customer supplied 11-pin octal-type sockets may be Between Terminals and Case — external potentiometer or resistor — ordered separately. 1,000VAC plus twice the nominal volt- On-Delay and Interval models only. SCC — 8- or 11-pin octal type sockets age for one minute. Accuracy — supplied with timer. (Must be used to Input Data @ 25°C Repeat Accuracy — ±0.5% ±0.004 sec. qualify as "UL Listed" device.) Overall Accuracy — ±2% max. Voltage — See Ordering Information Product Facts Weight — SCB: 5.3 oz. (149g) approx.; section for details. Reset Time — 25 ms. SCC: 7.5 oz. (210g) approx. n On-Delay, Off-Delay and Power Requirement — 3W, max. Relay Operate Time — Interval timing modes Off-Delay mode — 30 ms; Transient Protection: Non-repetitive tran- n 13 timing ranges from 0.1 Interval mode — 20 ms.. sients of the following magnitudes will not cause spurious operation of affect sec. to 60 min. Relay Release Time — function and accuracy. On-Delay mode only — 15 ms. n 10A DPDT output contacts Operating <0.1 ms <1 ms Voltage n Knob, fixed or external All except timing adjustment. 3,000V 2,500 12 & 24 n Rated for pilot duty 12 & 24 Consult Factory Users should thoroughly review the technical data before selecting a product n Premium components part number. It is recommended that user n File 3520, File E60363, also seek out the pertinent approvals File LR51332, files of the agencies/laboratories and File E60363 (SCC only) review them to ensure the product meets the requirements for a given application. Ordering Information (All "X's" must be included to complete part number) R R R 12 SCB RX 01 2XX A A XA | | | | | | | | | | | Series SCB Operating Mode Timing Range | | | | Series SCC 01 = On-Delay A =0 .1 to 3 sec. 1.97 .70 3.25 | | | | (50) (18) (83) | | | | Discrete 02 = Off-Delay B = 0.5 to 15 sec. | | | | Industrial 03 = Interval C = 1 to 30 sec. | | | | Timer D = 2 to 60 sec. 1.97 | | | (50) Output E = 4 to 120 sec. | | | 2XX = DPDT | F = 6 to 180 sec. | Mounting Series SCB | | Relay G = 10 to 300 sec. RX = 8- or 11-pin socket | | I = 2 to 60 min. Outline Dimensions | | (order separately) K = 3 to 180 cycles | | Mounting Series SCC L = 0.33 to 10 min. | | LA = 8-pin socket p/n | M = 0.5 to 15 min. | BCSA08SC for oper- | | Wiring Diagrams (Bottom Views) N = 1 to 30 min. ating mode 01 or 03 | | P = 0.1 to 10 min. | | with knob adjust or Insulated, shielded two-conductor | | fixed time. cable similar to BELDEN 8719, 8720 LC = 11-pin socket p/n Operating Voltage Timing Adjustment or 8769 required for leads longer BCSA11SC for oper- (+10%, –15%) XA = Knob Adjust than 6 inches. Max. permissible length is 50 feet. ating mode 02; or 01 A = 120VAC, 50/60 Hz. XB = External or 03 with external / 120VDC Potentiometer or resis- potentiometer or B = 240VAC, 50/60 Hz. tor (Operating modes 1 resistor. E = 24VAC, 50/60 Hz. / and 3 only). 24VDC XF =Fixed Times –Specify F = 48VAC, 50/60 Hz. / time delay in seconds 48VDC per the following Q = 12VDC examples: XF9.000 = 9 sec. Off-Delay On-Delay & Interval On-Delay & Interval XF99.00 = 99 sec. Fixed or Knob Fixed or Knob External Potentiometer XF999.0 = 9999 sec. Adjust Adjust or Resistor Adjust XF1000 = 1000 sec. Authorized distributors are likely to stock the following: BELDEN is a trademark of Belden None at present. Technologies, Inc. 12–35 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays SCE Series, Specification Grade Discrete Plug-in, True Off-Delay Time Delay Relay Accuracy — CAUTION: If unit has not been Input Data @ 25°C Repeat Accuracy — ±1 energized for several months, Voltage — See Ordering Information Overall Accuracy — ±5% apply operating voltage for 20 section for details Reset Time — 30 ms. min. minutes prior to initial time Power Requirement — 750mW Relay Operate Time — 30 ms. delay. Transient Protection — 1,000V plus twice rated voltage for 0.1 ms Contact Data @ 25°C Timing Specifications Arrangements — 1 Form C (SPDT) Timing Modes — Environmental Data and 2 Form C (DPDT) True Off-Delay — Upon application of Temperature Range — operating voltage (min. 100ms), output Rating — Storage — -40°C to +85°C relay contacts transfer. When operating 1 Form C — 10A @ 120/240VAC, Operating — -30°C to +65°C voltage is removed, the time delay resistive; 1/3 HP @ 120VAC; 345VA @ Mechanical Data period is initiated. At the end of the delay 120VAC; 1/4 HP @ 240VAC; 275VA @ period, output relay contacts release. Mounting/Termination — 8-pin 240VAC. Same polarity. If operating voltage is reapplied prior to octal plug fits either 27E122 or 27E891 2 Form C — 5A @ 28VDC or expiration of the delay period, the delay (snap-on) socket (order separately) 120/240VAC, resistive; 1/6 HP @ Product Facts will be cancelled and output relay con- 120/240VAC; 200VA @ 120/240VAC. Weight — 4 oz. (112g) approximately tacts will remain transferred. Same polarity. n True Off-Delay timing modes Timing Ranges — Expected Mechanical Life — n Six time delays from 0.1 0.1 to 3 / 0.5 to 15 / 1 to 30 / 4 to 120 / 10 million operations sec. to 10 min. 10 to 300 sec.; 0.33 to 10 min. Expected Electrical Life — 200,000 Timing Adjustment — operations, min., at rated resistive load n 10A SPDT or 5A DPDT Knob adjustment — Internal poten- output contacts Initial Dielectric Strength — tiometer with external knob adjustment. Between Terminals and Case and relay n Excellent repeat Maximum time calibrated with +10%, – contacts and active circuitry — accuracy — typically better 0% of values shown below at rated volt- 1,480VAC for one minute age, at 68°F. than ±1% Fixed time — internal fixed resistor. n 8-pin octal plug. n File E15631, File LR51332 Users should thoroughly review the technical data before selecting a product R R part number. It is recommended that user Ordering Information (All "X's" must be included to complete part number) also seek out the pertinent approvals files of the agencies/laboratories and SCE R X 2 2 A C A review them to ensure the product meets | | | | | | | | the requirements for a given application. | | | | Series SCE Output Rating Output Timing Range | | | | True W = 10A (SPDT) 1 = SPDT (W) A =0 .1 to 3 sec. | | | | | | | | Off-delay X = 5A (DPDT) 2 = DPDT (W) B = 0.5 to 15 sec. | | | | Timer C = 1 to 30 sec. .60 3.25 1.97 | | | | (50) (15) (83) E = 4 to 120 sec. | | Agency Operating G = 10 to 300 sec. | | Recognition Mode | L = 0.33 to 10 min. | | | R = UL recognized 2 = True 1.97 | Off-Delay (50) Operating Voltage | (+10%, –15%) | A = 120VAC, 50/60 Timing Adjustment Hz. / 125VDC Outline Dimensions A = Knob Adjust E = 24VAC, 50/60 Hz. F = Fixed Times –Specify / 24VDC time delay in seconds F = 48VAC, 50/60 Hz. per the following / 48VDC examples: XF9.000 = 9 sec. Wiring Diagrams (Bottom Views) XF99.00 = 99 sec. XF999.0 = 9999 sec. XF1000 = 1000 sec. Fixed Time Fixed Time Or Knob Adjust Or Knob Adjust Authorized distributors are likely to stock the following: None at present. 12–36 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays SCF Series, Programmable, Time Delay Relay Timing Modes Contact Data @ 25°C Operating <0.1 ms <1 ms Voltage Modes are user selectable via screw- Arrangements — 2 Form C (DPDT). 12VDC 1,000V 240V* driver adjustment of recessed 4-position Rating — 10A @ 28VDC or 120VAC, 24VAC/VDC 1,000V 240V* selector dial. resistive; 1/3 HP @ 120/240VAC; 48 VAC/VDC 1,000V 480V* Modes offered are: On-Delay, Off-Delay, 345VA. 120 VAC, Interval and Latching Interval. Expected Mechanical Life — 3,000V 2,500V* 125VDC 10 million operations. Timing Specifications 240VAC/VDC 3,000V 2,500V* Expected Electrical Life — 500,000 Timing Ranges — 0.1 to 3 / 0.33 to *Minimum source impedance of 100 ohm operations, min., at rated resistive load. 10 / 1 to 30 / 4 to 120 sec.; 0.33 to 10 / Environmental Data Initial Dielectric Strength — 1 to 30 / 2 to 60 min.; 0.33 to 10 hr. Between Terminals and Case — Temperature Range — Timing Range Selection — 1,000VAC plus twice the nominal volt- Storage — -40°C to +85°C. Screwdriver select via recessed age for one minute. Operating — -30°C to +65°C. 8-position selector dial. Input Data @ 25°C Timing Adjustment — External knob Mechanical Data Product Facts potentiometer adjustment with reference Voltage — See Ordering Information Mounting/Termination — 11-pin calibrations. section for details. octal-type plug for use with mating n 4 user-programmable Accuracy — socket. Mount relay in horizontal position Power Requirement — 2W, max. timing modes Repeat Accuracy — ±1% ±0.01 sec. (pins horizontal, knob down, LEDs up). Transient Protection — n 0.1 sec. to 10 hr. Overall Accuracy — ±3% ±0.01 sec. Status Indication — Power On LED Non-repetitive transients of the following programmable timing range Reset Time — 30 ms. and Output Contacts LED. magnitudes will not cause spurious operation of affect function and accuracy. Relay Operate Time — On-Delay Weight — Relay: 3.5 oz. (156g) n Parameters set with and Interval mode: 55 ms. approx.; Socket: 1.7 oz. (48.3g) approx. recessed dials Relay Release Time — Off-Delay, n Narrow width saves panel Interval and Latching Interval: 40 ms. space n 10A DPDT output relay Outline Dimensions n Socket can be DIN-rail or M3 X 0.5 CAPTIVE .84 back panel mounted CLAMP SCREWS (21) CLEARANCE HOLE FOR M4 OR #8 n File E15631(relay) and MACHINE E140494 (socket) SCREW R 3.29 (84) n File LR29186 (relay) and 12 1.38 LR29513M7 (socket) 1.645 R (35) (42) 0.372 (10) .21 Users should thoroughly review the 1.42 (5) (36) technical data before selecting a product 0.71 .109 (3) DIA. part number. It is recommended that user (18) ANTI-ROTATION PIN BETWEEN also seek out the pertinent approvals TERMS 10 & 2 files of the agencies/laboratories and review them to ensure the product meets SCF Timer BCSF11SC Socket the requirements for a given application. Ordering Information (All "X's" must be included to complete part number) SCF RX 90 2 A A | | | | | | | | | Series SCF Operating Mode Output Rating | | | Plug-In | | | | | | Programmable 90 = Multiple Modes A = 10 Amp | | | Timer On-Delay B = 5 Amp | | | Off-Delay | | | Interval | | | | Latching Interval | | | | Output Mounting Operating Voltage (+10%, –15%) 2 = DPDT Relay RX = Without Socket RF = With Socket A = 120VAC, 50/60 Hz. / 125VDC Wiring Diagram B = 240VAC, 50/60 Hz. § (Bottom View) E = 24VAC, 50/60 Hz. / 24VDC § Voltage Option B is only available with F = 48VAC, 50/60 Hz. / 24VDC 5 Amp output option. Q = 12VDC Authorized distributors are likely to stock the following: None at present. 12–37 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays SRC Series, Specification Grade Repeat Cycle, Plug-in Time Delay Relay Timing Specifications Contact Data @ 25°C Operating <0.1 ms <1 ms Voltage Timing Modes — Arrangements — 2 Form C (DPDT). 12VDC 1,000V 240V* Repeat Cycle: Application of line voltage Rating — 10A @ 28VDC or 120VAC, 12VDC 1,000V 240V* starts the pre-set OFF-time period Upon resistive; 1/3 HP @ 120/240VAC. 24VAC/VDC 1,000V 240V* expiration of the period, the output relay Expected Mechanical Life — 48 VAC/VDC 1,000V 480V* is energized, its contacts transfer, and 10 million operations the pre-set ON-time period begins. At 120 VAC/VDC 3,000V 2,500V* Expected Electrical Life — 500,000 the end of this period the output relay is 240VAC 3,000V 2,500V* operations, min., at rated resistive load. deenergized, and a new cycle begins. *Minimum source impedance of 100 ohm Initial Dielectric Strength — The OFF and ON cycles continue until Between Terminals & Case and Mutually Environmental Data power is removed. To reset the timer, Isolated Contacts — 1,480VAC. input voltage must be removed for at Temperature Range — least 25 ms. Storage — -40°C to +85°C Input Data @ 25°C Operating — -30°C to +65°C Timing Ranges — OFF time and ON Voltage — See Ordering Information time ranges need not be the same. section for details. Mechanical Data 6 to 180 cycles; 0.1 to 3 / 1 to 10 / 0.5 Product Facts Power Requirement — 3W max. Mounting/Termination — to 15 / 1 to 30 / 2 to 60 / 4 to 120 / 6 to Transient Protection — Non-repeti- Quick connect terminals fit either n Repeat Cycle timing mode 180 / 10 to 300 sec.; 0.33 to 10 / 0.5 to tive transients of the following magni- 27E121 or 27E893 (snap-on) socket 15 / 1 to 30 / 2 to 60 min. (All are n Dual knobs for user tudes will not cause spurious operation (order separately) +10%, –1% of maximum values). adjustment of on and off of affect function and accuracy. Weight — 5.3 oz. (149g) approximately Timing Adjustment — Two internal times potentiometers with external knobs. n 13 timing ranges from 0.1 Accuracy — sec. to 60 min. Repeat Accuracy — ±1% ±0.004 sec. Overall Accuracy — ±2.25% max. n 10A DPDT output contacts Reset Time — 25 ms. max. (between n Exceptional immunity to line deenergization and reenergization with- transients and noise out affecting accuracy.) Relay Operate Time — 20 ms. n Premium components Relay Release Time — 15 ms. enhance reliability Ordering Information n Superior reset time of 24 SRC 7 2 A C C A msec. | | | | | | | | | | Series SRC Output Timing Range Timing | | | Repeat 2 = DPDT Off-Time Adjustment | | | Users should thoroughly review the Cycle | Relay | A =0 .1 to 3 sec. | A = Dual Knob technical data before selecting a product | | | Timer. B = 0.5 to 15 sec. Adjust | | | part number. It is recommended that user C = 1 to 30 sec. | | also seek out the pertinent approvals Operating Mode D = 2 to 60 sec. | | files of the agencies/laboratories and 7= Repeat Cycle E = 4 to 120 sec. | | review them to ensure the product meets | | F = 6 to 180 sec. | | the requirements for a given application. G = 10 to 300 sec. | | I = 2 to 60 min. | | K = 3 to 180 cycles | Timing Range | L = 0.33 to 10 min. On-Time | M = 0.5 to 15 min. | A =0 .1 to 3 sec. N = 1 to 30 min. 1.97 3.7 MAX. | B = 0.5 to 15 sec. (50) .40 P = 0.1 to 10 sec. (94) | C = 1 to 30 sec. (10) Operating Voltage D = 2 to 60 sec. (+10%, –15%) E = 4 to 120 sec. 1.97 A = 120VAC, 50/60 F = 6 to 180 sec. (50) Hz. / 120VDC G = 10 to 300 sec. B = 240VAC, 50/60 I = 2 to 60 min. Hz. K = 3 to 180 cycles E = 24VAC, 50/60 Hz. L = 0.33 to 10 min. Outline Dimensions / 24VDC M = 0.5 to 15 min. F = 48VAC, 50/60 Hz. N = 1 to 30 min. / 48VDC P = 0.1 to 10 sec. Q = 12VDC Authorized distributors are likely to stock the following: Wiring Diagram (Bottom View) None at present. 12–38 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays SSC Series, Specification Grade Discrete Plug-in, Time Delay Relay Timing Specifications Contact Data @ 25°C Input Data @ 25°C Timing Modes — Arrangements — 2 Form C (DPDT). Voltage — See Ordering Information On-Delay, Off-Delay and Interval. section for details. Rating — 10A @ 28VDC or 120VAC, Timing Ranges — 6 to 180 cycles; resistive; 1/3 HP @ 120/240VAC. Power Requirement — 3W max. 0.1 to 3 / 0.1 to 10 / 0.33 to 10 / 1 to 30 Expected Mechanical Life — Transient Protection — / 4 to 120 sec.; 0.33 to 10 / 1 to 30 / 2 to 10 million operations Non-repetitive transients of the following 60 min.; 0.33 to 10 hr. (All are +10%, – magnitudes will not cause spurious Expected Electrical Life — 500,000 1% of maximum values). operation of affect function and accuracy. operations, min., at rated resistive load. Timing Adjustment — Knob or fixed Operating Initial Dielectric Strength — <0.1 ms <1 ms time (internal fixed resistor) – all mod- Voltage Between Terminals and Case — els; customer supplied external poten- 12VDC 1,000V 240V* 1,000VAC plus twice the nominal tiometer or resistor – On-Delay and 12VDC 1,000V 240V* voltage for one minute. Interval models only. 24VAC/VDC 1,000V 240V* Accuracy — 48 VAC/VDC 1,000V 480V* Repeat Accuracy — ±1% ±0.004 sec. at Product Facts 120 VAC/VDC 3,000V 2,500V* any combination of operating tempera- 240VAC 3,000V 2,500V* n On-Delay, Off-Delay and ture and voltage. *Minimum source impedance of 100 ohm Interval timing modes Overall Accuracy — ±5.25% throughout operating temperature and voltage Environmental Data n 13 timing ranges from 0.1 ranges. Temperature Range — sec. to 60 min. Reset Time — 25 ms. (minimum Storage — -40°C to +85°C n 10A DPDT output contacts deenergized interval for on-delay or off- Operating — -30°C to +65°C delay models, or minimum required clo- n Excellent repeatability of Mechanical Data sure interval for interval models without ±1% or better. affecting accuracy.) Mounting/Termination — 8- or 11-pin octal type plug. 8-pin types n Exceptional immunity to Relay Operate Time — Off-Delay fit either 27E122 or 27E891, while mode only: 35 ms. transients and noise. 11-pin types fit 27E123 or 27E892. Relay Release Time — On-Delay n Wide operating temperature Weight — 4 oz. (112g) approximately mode only: 20 ms. range. n File 3520, File LR29186 R Ordering Information 12 SSC 01 2 A A A Users should thoroughly review the technical data before selecting a product | | | | | | part number. It is recommended that user | | | Series SSC Output Timing Range also seek out the pertinent approvals | | | Discrete 2 = DPDT Relay A =0 .1 to 3 sec. | | | files of the agencies/laboratories and | | | Industrial B = 0.5 to 15 sec. review them to ensure the product meets | | | Timer C = 1 to 30 sec. the requirements for a given application. | | | D = 2 to 60 sec. | | Operating Mode E = 4 to 120 sec. | | 1.97 .70 3.25 01 = On-Delay | F = 6 to 180 sec. | (50) (18) (83) | | 02 = Off-Delay G = 10 to 300 sec. | | 03 = Interval I = 2 to 60 min. | | 1.97 K = 3 to 180 cycles | | (50) L = 0.33 to 10 min. | | | M = 0.5 to 15 min. | | | N = 1 to 30 min. | | Outline Dimensions P = 0.1 to 10 min. | | Insulated, shielded two-conductor Operating Voltage Timing Adjustment cable similar to BELDEN 8719, (+10%, –15%) A = Knob Adjust 8720 or 8769 required for leads A = 120VAC, 50/60 Hz. B = External Potentiometer longer than 6 inches. Max. / 120VDC or resistor (Operating permissible length is 50 feet. B = 240VAC, 50/60 Hz. modes 1 and 3 only). E = 24VAC, 50/60 Hz. / F = Fixed Times –Specify 24VDC time delay in seconds F = 48VAC, 50/60 Hz. / per the following 48VDC examples: Q = 12VDC (±10%) F9.000 = 9 sec. F99.00 = 99 sec. F999.0 = 9999 sec. Off-Delay On-Delay & Interval On-Delay & Interval F1000 = 1000 sec. Fixed or Knob Fixed or Knob External Potentiometer Adjust Adjust or Resistor Adjust Authorized distributors are likely to stock the following: Wiring Diagrams (Bottom Views) SSC12AAA SSC12ACA SSC12AGA BELDEN is a trademark of Belden Technologies, Inc. SSC12ABA SSC12ADA SSC12ALA 12–39 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays SSF Series, Programmable Time Delay Relay Transient Protection — Timing Specifications Contact Data @ 25°C Non-repetitive transients of the following Timing Modes — Arrangements — 2 Form C (DPDT). magnitudes will not cause spurious Modes are user selectable via Rating — 10A @ 28VDC or 120VAC, operation of affect function and accuracy. screwdriver adjustment of recessed resistive; 1/3 HP @ 120/240VAC 345VA. 4-position selector dial. Operating Expected Mechanical Life — <0.1 ms <1 ms Voltage Modes offered are: On-Delay, Off-Delay, 10 million operations (with factory- 24, Interval and Latching Interval. 1,000V 480V installed relay). 48 VAC/VDC Timing Ranges — 0.1 to 3 / 0.33 to Expected Electrical Life — 500,000 120, 10 / 1 to 30 / 4 to 120 sec.; 0.33 to 10 / 3,000V 2500V* 240VAC/VDC operations, min., at rated resistive load 1 to 30 / 2 to 60 min.; 0.33 to 10 hr. (with factory-installed relay). * Min. source impedance of 100 Timing Range Selection — ohm@120/240VAC, 3000V <0.1 , Initial Dielectric Strength — Screwdriver select via recessed sec.Environmental Data Between Coil/Control Switch and 8-position selector dial. Contacts — 1,500VAC for one minute. Environmental Data Timing Adjustment — Recessed Input Data @ 25°C Temperature Range — potentiometer adjustment with reference Product Facts Storage — -40°C to +85°C calibrations. Voltage — See Ordering Information n 4 user-programmable Operating — -30°C to +65°C section for details. Accuracy — timing modes Repeat Accuracy — ±1% ±0.01 sec. Power Requirement — 2W max. Mechanical Data Overall Accuracy — ±3% ±0.01 sec. n 0.1 sec. to 10 hr. Mounting/Termination — Panel, Reset Time — 30 ms. programmable timing range DIN-rail, Machine Tool mounting track Relay Operate Time — On-Delay mounting case with screw terminals. n Parameters set with and Interval mode: 30 ms. Weight — 5.5 oz. (156g) approxi- recessed screwdriver dials Relay Release Time — Off-Delay, mately n Universal voltage (plug-in Interval and Latching Interval: 30 ms. (with factory-installed relay). relay dependent) n 10A DPDT replaceable output relay minimizes 0.188 (5) WIDE SLOT FOR #8 OR M4 MACHINE SCREW 2.19 downtime 2.67 (56) 1.095 (68) (28) n Front screw terminals 0.342 (9) n DIN-rail, panel or machine tool track mount 3.125 2 3 4 5 n File E15631, File LR29186 (79) 1 6 DIN HOLE R TRACK PATTERN 3.81 R (97) MOUNT FOR SCREW MOUNT 8 10 7 9 Users should thoroughly review the 0.343 (9) technical data before selecting a product 0.322 6-32 CAPTIVE part number. It is recommended that user (8) CLAMP SCREWS also seek out the pertinent approvals Outline Dimensions files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Ordering Information SSF R 90 A || | | Series SSF R = UL Operating Mode 90 Operating Voltage Universal Recognized Multiple modes - (+10%, –15%) Timer Component On-Delay A = 120VAC, 50/60 Hz. Off-Delay B = 240VAC, 50/60 Hz. Interval E = 24VAC, 50/60 Hz. Latching Interval F = 48VAC, 50/60 Hz. N = 48VDC O =24VDC P = 125VDC X = No factory-installed relay.† † Voltage determined by customer-supplied relay. Only relays that operate on the above-listed voltages should be used. Timer operation using other relay voltages is not recommended. Authorized distributors are likely to stock the following: Wiring Diagram (Top View) SSFR90A SSFR90X 12–40 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays SST Series, Industrial Grade Discrete Plug-in, Time Delay Relay Expected Mechanical Life — Timing Specifications Operating <0.1 ms <1 ms 10 million operations Voltage Timing Modes — 12VDC 1,000V 240V* Expected Electrical Life — 500,000 On-Delay, Off-Delay, Interval, One Shot operations, min., at rated resistive load. 12 & (Latching Interval) or Repeat Cycle. 860V 208V* 24 VAC/VDC Initial Dielectric Strength — Timing Ranges — Nine ranges span- 120 VAC 2,580V 2,150V* Between Contacts, Line Inputs and ning 0.1 sec. to 120 min. *Minimum source impedance of 100 ohm. Control Circuits — 1,500V RMS, Timing Adjustment — Knob adjust. minimum, at 60 Hz. Environmental Data Accuracy — Repeat Accuracy — ±1% Input Data @ 25°C Temperature Range — Overall Accuracy — ±5% Storage — -23°C to +71°C Voltage — See Ordering Information Operating — -23°C to +54°C Reset Time — 50 ms., max., (25 ms section for details. typ.) for on-delay and interval; 300 ms, Power Requirement — 3W max. Mechanical Data max., for off-delay and one shot; 500 Transient Protection — Mounting/Termination — On-Delay, ms, max., for repeat type. Non-repetitive transients of the following Interval and Repeat types have 8- pin Product Facts Relay Operate Time — 50 ms. magnitudes will not cause spurious octal plug that fits either 27E122 or Relay Release Time — 30 ms. operation of affect function and accuracy. n On-Delay, Off-Delay, 27E891 socket. Off-Delay and One Shot types have 11-pin octal-type plug that Interval, One Shot & Repeat Contact Data @ 25°C fits 27E123 or 27E892. Sockets must be modes Arrangements — 2 Form C (DPDT) ordered separately. n Time delays to 120 min. Rating — 10A @ 120/240VAC, resis- Weight — 4 oz. (112g) approximately tive; 1/3 HP @ 120/240VAC, 50/60 Hz. n Fast setting with time calibrated knobs n Superior transient protection 2.0 MAX. (50.8) n Rugged construction with SQUARE 8- or 11-pin plug .812 MAX. 3.20 MAX. n Flame retardant housing (20.6) (81.3) 4.60 MAX. (116.8) n File E15631, File LR33434 R Outline Dimensions Wiring Diagrams (Bottom Views) R 12 Ordering Information SST1 – On Delay Types SST2 – Off Delay Types SST4 – One Shot* Types SST7 – Repeat Cycle Types Input Time Range Part No. Input Time Range Part No. Input Time Range Part No. Input Time Range Part No. 0.1 - 10 sec. SST12AAA 0.1 - 10 sec. SST22AAA 0.1 - 10 sec. SST42AAA 0.1 - 10 sec. SST72AAA 0.6 - 60 sec. SST12ACA 1.8 - 180 sec. SST22ADA 1.8 - 180 sec. SST42ADA 1.8 - 180 sec. SST72ADA 120 120 120 1.8 - 180 sec. SST12ADA 3 - 300 sec. SST22AEA 3 - 300 sec. SST42AEA 3 - 300 sec. SST72AEA 120 VAC VAC VAC VAC 3 - 300 sec. SST12AEA 18 sec. - 30 min. SST22AGA 18 sec. - 30 min. SST42AGA 18 sec. - 30 min. SST72AGA 18 sec. - 30 min. SST12AGA 36 sec. - 60 min. SST22AHA 36 sec. - 60 min. SST42AHA 36 sec. - 60 min. SST72AHA 36 sec. - 60 min. SST12AHA 0.1 - 10 sec. SST22EAA 0.1 - 10 sec. SST42EAA 0.1 - 10 sec. SST72EAA 24 24 24 VAC VAC VAC 0.1 - 10 sec. SST12EAA 1.8 - 180 sec. SST22EDA 1.8 - 180 sec. SST42EDA 1.8 - 180 sec. SST72EDA 24 1.8 - 180 sec. SST12EDA 0.1 - 10 sec. SST22OAA 0.1 - 10 sec. SST42OAA 0.1 - 10 sec. SST72OAA 24 24 24 VAC VDC VDC VDC 3 - 300 sec. SST12EEA 1.8 - 180 sec. SST22ODA 1.8 - 180 sec. SST42ODA 1.8 - 180 sec. SST72ODA 0.1 - 10 sec. SST12OAA 0.1 - 10 sec. SST22QAA 0.1 - 10 sec. SST42QAA 0.1 - 10 sec. SST72QAA 12 12 12 24 VDC VDC VDC 1.8 - 180 sec. SST12ODA 1.8 - 180 sec. SST22QDA 1.8 - 180 sec. SST42QDA 1.8 - 180 sec. SST72QDA VDC 3 - 300 sec. SST12OEA * Also known as Latching Interval SST3 – Interval Types 0.1 - 10 sec. SST12QAA 12 Input Time Range Part No. 1.8 - 180 sec. SST12QDA VDC 0.1 - 10 sec. SST32AAA 3 - 300 sec. SST12QEA 1.8 - 180 sec. SST32ADA 120 VAC 3 - 300 sec. SST32AEA 36 sec. - 60 min. SST32AHA 0.1 - 10 sec. SST32EAA 24 VAC 1.8 - 180 sec. SST32EDA Users should thoroughly review the technical data before selecting a product 0.1 - 10 sec. SST32OAA 24 part number. It is recommended that user VDC 1.8 - 180 sec. SST32ODA also seek out the pertinent approvals 0.1 - 10 sec. SST32QAA 12 files of the agencies/laboratories and Authorized distributors are likely to stock the following: VDC 1.8 - 180 sec. SST32QDA review them to ensure the product meets None at present. the requirements for a given application. 12–41 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays STA Series, Specification Grade Discrete Plug-in, Time Delay Relay With QC Terminals Timing Specifications Contact Data @ 25°C Input Data @ 25°C Timing Modes — Arrangements — 2 Form C (DPDT). Voltage — See Ordering Information On-Delay, Off-Delay, Interval and section for details. Rating — 10A @ 28VDC or 120VAC, Accumulating On-Delay. resistive; 1/3 HP @ 120/240VAC; Power Requirement — 3W max. Timing Ranges — 6 to 180 cycles; 345VA. Same polarity. Transient Protection — 0.1 to 3 / 0.5 to 15 / 1 to 30 / 2 to 60 / Expected Mechanical Life — Non-repetitive transients of the following 4 to 120 / 6 to 180 / 10 to 300 sec.; 10 million operations magnitudes will not cause spurious 0.33 to 10 / 0.5 to 15 / 1 to 30 min.; operation of affect function and accuracy. Expected Electrical Life — 500,000 1 to 6 / 2 to 48 hr. (All are +5%, –0% of operations, min., at rated resistive load. Operating maximum values). <0.1 ms <1 ms Voltage Initial Dielectric Strength — Timing Adjustment — Knob or fixed All except 1,000VAC plus twice the nominal 3,000V 2,500 time (internal fixed resistor) – all mod- 12 & 24 voltage for one minute. els; customer supplied external poten- Consult 12 & 24 Factory tiometer or resistor – On-Delay and Interval models only. Environmental Data Accuracy — Temperature Range — Repeat Accuracy — ±.5% ±0.004 sec. Storage — -40°C to +85°C Product Facts Overall Accuracy — ±2% throughout Operating — -30°C to +65°C operating temperature and voltage n On-Delay, Off-Delay, ranges. Mechanical Data Interval and Accumulating Reset Time — 30 ms. min. (between Mounting/Termination — On-Delay timing modes deenergization and reenergization with- Quick connect terminals fit either n 13 timing ranges from out affecting accuracy.) 27E121 or 27E893 (snap-on) socket (order separately). 0.1 sec. to 48 hr. Relay Operate Time — Off-Delay mode: 35 ms.; Interval mode — 20 ms. Status Indication — Power On LED n 10A DPDT output contacts and Output Contacts LED (optional). Relay Release Time — On-Delay n Knob, fixed or external and Accumulating On-Delay modes — Weight — 4.2 oz. (119g) approxi- timing adjustment 20 ms mately. n QC plug-in terminals save space, two LEDs show Users should thoroughly review the Ordering Information (All "X's" must be included to complete part number) technical data before selecting a product status part number. It is recommended that user S STA RX 01 2X A A XA n File 3520, File E60363, also seek out the pertinent approvals File LR51332 files of the agencies/laboratories and | | | | | | | | | | | | review them to ensure the product meets R Series STA Operating Mode Status Timing Range | | | | R the requirements for a given application. Indication Discrete 01 = On-Delay A =0 .1 to 3 sec. | | | | Industrial | 02 = Off-Delay | S = LEDs | B = 0.5 to 15 sec. | | | | | X = No LEDs Timer 03 = Interval C = 1 to 30 sec. | | | | With 09 = Accumulating D = 2 to 60 sec. | | | | Tab-type On-Delay E = 4 to 120 sec. | | | | 1.500 MAX. Terms. F = 6 to 180 sec. | | | | (38) | | | | G = 10 to 300 sec. | | I = 2 to 60 min. Mounting Series Output | | .281 REF. .660 MAX. 3.045 1.390 MAX. J = 1 to 6 hr. RX = 11-pin tab-type 2X = DPDT | | (7) (17) (77) (35) K = 3 to 180 cycles header (order socket Relay | | | L = 0.33 to 10 min. | separately) Outline Dimensions | | M = 0.5 to 15 min. | | N = 1 to 30 min. | | Insulated, shielded two-conductor R = 2 to 48 hr. | | cable similar to BELDEN 8719, | | 8720 or 8769 required for leads longer than 6 inches. Maximum per- Operating Voltage Timing Adjustment missible length is 50 feet. (+10%, –15%) XA = Knob Adjust A = 120VAC, 50/60 XB = External Hz. / 120VDC Potentiometer or E = 24VAC, 50/60 Hz. resistor (Operating / 24VDC modes 1 and 3 only). F = 48VAC, 50/60 Hz. XF =Fixed Times –Specify / 48VDC time delay in seconds Q = 12VDC per the following Off-Delay & On-Delay On-Delay examples: Accumulating && XF9.000 = 9 sec. On-Delay Interval Interval XF99.00 = 99 sec. Fixed or Knob Fixed or Knob External Potentiometer XF999.0 = 9999 sec. Adjust Adjust or Resistor Adjust XF1000 = 1000 sec. Wiring Diagrams (Bottom Views) Authorized distributors are likely to stock the following: BELDEN is a trademark of Belden Technologies, Inc. None at present. 12–42 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays VTM1 Series, On-Delay, Timing Module Timing Specifications Output Switch Data Input Data @ 25°C Timing Mode — On-Delay Arrangement — Solid state 1 Form A Voltage — 12 VAC/VDC, 24VAC/VDC, (SPST-NO) 120 VAC/VDC. Timing Ranges — 0.5 to 10 / 3 to 60 sec.; 0.5 to 10 / 3 to 60 min. Rating — 1A, inductive, at nominal Power Requirement — 3W max. operating voltage. Timing Range Selection — Transient Protection — Screwdriver select via recessed Expected Electrical Life — Non-repetitive transients of the following 8-position selector dial. 10,000,000 operations at rated load. magnitudes will not cause spurious operation of affect function and accuracy. Timing Adjustment — External Initial Dielectric Strength — resistor or potentiometer. An external Between Terminals and Mounting — Operating <0.1 ms <1 ms Voltage resistance of 1 megohm is required to 3,000VAC rms. obtain the maximum time for all ranges. Between Input and Output — 12, 860V* 208V* 24 VAC/VDC To determine the actual resistance 1,500VAC rms. 120 VAC/VDC 2,580V 2,150V* needed to obtain the required time delay, use the following formula: * Min. source impedance of 100 ohm. (T - T ) REQ MIN Environmental Data R = x 1,000,000 ohms T Product Facts T - T MAX MIN Temperature Range — Accuracy — n On-delay timing mode Storage — -40°C to +85°C Repeat Accuracy — ±1% Operating — -40°C to +65°C n Reliable solid state timing Overall Accuracy — ±2% at circuitry Mechanical Data R = 1 megohm Mounting — Panel mount with one Reset Time — 100 ms, max., before n Excellent transient #8 screw. time-out; 10 ms, max., after time-out. protection Termination — 0.250 in (6.35) quick n Compact design connect terminals. Weight — 3 oz. (84g) approximately n Flame retardant, solvent 1.25 resistant housing 2.00 (31.8) (50.8) .885 n File E60363, File LR33434 (22.5) R R 2.00 (50.8) 12 .170 DIA (4.32) .250 (6.35) X .032 (.813) QUICK CONNECTS ACCEPTS #8 SCREW Outline Dimensions An external resistance of 1 megohm is required to obtain the maximum time LOAD for all ranges. To determine the actual resistance needed to obtain the required INPUT time delay, use the following formula: VOLTAGE (T - T ) REQ MIN R = x 1,000,000 ohms T T - T MAX MIN Wiring Diagram Ordering Information VTM1 A CD || | Series VTM1 Input Voltage Time Range On-Delay A = 120VAC/VDC CD = 0.5 - 10 sec. Timing Module E = 24VAC/VDC DD = 3 - 60 sec. Q = 12VAC/VDC FD = 0.5 - 10 min. GD = 3 - 60 min. Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals Authorized distributors are likely to stock the following: files of the agencies/laboratories and VTM1ECD review them to ensure the product meets the requirements for a given application. VTM1EDD 12–43 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays VTM-1 Series, Specification Grade, On-Delay, Timing Module Timing Specifications Output Switch Data Input Data @ 25°C Timing Mode — On-Delay – VTM-1 Arrangement — 1 Form A (SPST-NO) Operating Voltage — Universal — in-line timing module is wired in series 24-240VAC/VDC (19-288VAC/VDC). Rating — 5A, inductive, at nominal with the load circuit. Time delay is operating voltage. Current — 2mA (max.) required to initiated when power is applied to the operate timer regardless of output state. Inrush — Not to exceed 10A for one series network. Connecting a resistor cycle. Power Requirement — 3W max. across the center terminals provides Max. Leakage Current — 4mA rms Transient Protection — tamper-proof setting of time delay from MOV across input 2,000V for 11μs on Expected Electrical Life — 1-1000 sec. line side of load. 10,000,000 operations at rated load. Timing Ranges — 1 to 1,000 sec. Initial Dielectric Strength — Environmental Data Timing Adjustment — Time delay is Between Active Terminals and Outside set by connecting an appropriately rated Temperature Range — of Case — 1,480VAC for one min. resistor or potentiometer between the cen- Storage — -40°C to +85°C ter two terminals. As supplied, the unit pro- Operating — -30°C to +65°C vides a nominal 1 second delay. Add 10k Product Facts Mechanical Data ohm of resistance for every additional sec- n On-delay timing mode Mounting — Screw mount in horizon- ond of delay required. For example: 5 sec- tal or vertical position through built-in onds = 40k ohms; 10 seconds = 90k ohms. n Timing from 1 to 1000 sec. mounting ears. Accuracy — n 1A solid state SPST-NO Termination — 0.250 in (6.35) quick Repeat Accuracy — ±2% output connect terminals for input line, load Reset Time — 100 ms, max., in the output and timing resistor connection. timing or time-out condition. n 0.25" (6.35) quick connect Weight — 3 oz. (84g) approximately terminals n Universal voltage: 24 to 240VAC/VDC n Rated to 10 million operations n File E60363, File LR51332 R R Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Outline Dimensions Ordering Information Part Number Mode Input Voltage Wiring Diagram || | VTM-1 On-Delay 24-240VAC or VDC Notes: 1. Do not operate timer without connect- ing load in series with line voltage. 2. For a time delay of 1 second, connect Authorized distributors are likely to stock the following: a jumper across the center two terminals. VTM-1 12–44 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays VTM2 Series, Off-Delay, Timing Module Timing Specifications Output Switch Data Input Data @ 25°C Timing Mode — Off-Delay Arrangement — Solid state 1 Form A Voltage (±10%) — 12 VAC/VDC, (SPST-NO) 24VAC/VDC, 120 VAC/VDC. Timing Ranges — 0.5 to 10 / 3 to 60 sec.; 3 to 60 min. Rating — 1A, inductive, at nominal Power Requirement — 4W with operating voltage. rated load Timing Adjustment — External resistor or potentiometer. An external Expected Electrical Life — Transient Protection — resistance of 1 megohm is required to 10,000,000 operations at rated load. Non-repetitive transients of the following obtain the maximum time for all ranges. magnitudes will not cause spurious Initial Dielectric Strength — To determine the actual resistance operation of affect function and accuracy. Between Terminals and Mounting — needed to obtain the required time delay, 3,000VAC rms. Operating <0.1 ms <1 ms use the following formula: Voltage Between Input and Output — (T - T ) 1,500VAC rms. 12, REQ MIN 860V* 208V* R = x 1,000,000 ohms T 24 VAC/VDC T - T MAX MIN 120 VAC/VDC 2,580V 2,150V* Accuracy — * Min. source impedance of 100 ohm. Repeat Accuracy — ±1% Product Facts Overall Accuracy — ±2% at Environmental Data R = 1 megohm n Off-delay timing mode Temperature Range — Reset Time — 50 ms, max. Storage — -40°C to +85°C n Reliable solid state timing Operating — -40°C to +65°C circuitry Mechanical Data n Excellent transient Mounting — Panel mount with one protection #8 screw. n Compact design Termination — 0.250 in (6.35) quick connect terminals. n Flame retardant, solvent 1.25 2.00 (31.8) resistant housing Weight — 4 oz. (112g) approximately (50.8) .885 (22.5) n File E60363, File LR33434 R R 2.00 (50.8) 12 .170 DIA (4.32) .250 (6.35) X .032 (.813) QUICK CONNECTS ACCEPTS #8 SCREW Ou tline Dimensions START POLARITY SHOWN SWITCH FOR DC An external resistance of 1 megohm MODELS is required to obtain the maximum time 1 5 for all ranges. To determine the actual LOAD 7 6 resistance needed to obtain the required R t time delay, use the following formula: 2 4 (T - T ) REQ MIN INPUT R = x 1,000,000 ohms T VOLTAGE T - T MAX MIN 3 Wiring Diagram Ordering Information VTM2 A CD || | Series VTM2 Input Voltage Time Range Off-Delay A = 120VAC/VDC CD = 0.5 - 10 sec. Timing Module E = 24VAC/VDC DD = 3 - 60 sec. Q = 12VAC/VDC GD = 3 - 60 min. Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and Authorized distributors are likely to stock the following: review them to ensure the product meets the requirements for a given application. None at present. 12–45 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays VTM3 Series, Interval, Timing Module Transient Protection — Timing Specifications Output Switch Data Non-repetitive transients of the following Timing Mode — Interval Arrangement — Solid state 1 Form A magnitudes will not cause spurious (SPST-NO) Timing Ranges — 0.5 to 10 / 3 to 60 operation of affect function and accuracy. sec.; 3 to 60 min. Rating — 1A, inductive, at nominal Operating operating voltage. Timing Adjustment — External <0.1 ms <1 ms Voltage resistor or potentiometer. An external Expected Electrical Life — 12, 860V* 208V* resistance of 1 megohm is required to 10,000,000 operations at rated load. 24 VAC/VDC obtain the maximum time for all ranges. Initial Dielectric Strength — 120 VAC/VDC 2,580V 2,150V* To determine the actual resistance Between Terminals and Mounting — * Min. source impedance of 100 ohms. needed to obtain the required time delay, 3,000VAC rms. Current Drain — Less than 5mA. use the following formula: Between Input and Output — (T - T ) 1,500VAC rms. REQ MIN Environmental Data R = x 1,000,000 ohms T T - T MAX MIN Temperature Range — Input Data @ 25°C Accuracy — Storage — -40°C to +85°C Voltage (±10%) — 12 VAC/VDC, Repeat Accuracy — ±1% Operating — -40°C to +65°C 24VAC/VDC, 120 VAC/VDC. Product Facts Overall Accuracy — ±2% at Mechanical Data Power Requirement — 4W with R = 1 megohm n Interval timing mode rated load Mounting — Panel mount with one Reset Time — 50 ms, max. n Reliable solid state timing #8 screw. circuitry Termination — 0.250 in (6.35) quick connect terminals. n Excellent transient Weight — 4 oz. (112g) approximately protection n Compact design n Flame retardant, solvent 1.25 2.00 (31.8) resistant housing (50.8) .885 (22.5) n File E60363, File LR33434 R R 2.00 (50.8) .170 DIA (4.32) .250 (6.35) X .032 (.813) QUICK CONNECTS ACCEPTS #8 SCREW Ou tline Dimensions POLARITY SHOWN FOR DC An external resistance of 1 megohm MODELS is required to obtain the maximum time 1 5 LOAD for all ranges. To determine the actual R resistance needed to obtain the required t time delay, use the following formula: 2 4 INPUT (T - T ) REQ MIN R = x 1,000,000 ohms VOLTAGE T 3 T - T MAX MIN Wiring Diagram Ordering Information VTM3 A CD || | Series VTM3 Input Voltage Time Range Interval A = 120VAC/VDC CD = 0.5 - 10 sec. Timing Module E = 24VAC/VDC DD = 3 - 60 sec. Users should thoroughly review the Q = 12VAC/VDC GD = 3 - 60 min. technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and Authorized distributors are likely to stock the following: review them to ensure the product meets the requirements for a given application. None at present. 12–46 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays VTM4 Series, One Shot (Latching Interval), Timing Module Timing Specifications Output Switch Data Input Data @ 25°C Timing Mode — One Shot (Latching Arrangement — Solid state 1 Form A Voltage (±10%) — 12 VAC/VDC, Interval) (SPST-NO) 24VAC/VDC, 120 VAC/VDC. Timing Ranges — 0.5 to 10 / 3 to 60 Rating — 1A, inductive, at nominal Power Requirement — 4W with sec.; 0.5 to 10 / 3 to 60 min. operating voltage. rated load Timing Adjustment — External Expected Electrical Life — Transient Protection — resistor or potentiometer. An external 10,000,000 operations at rated load. Non-repetitive transients of the following resistance of 1 megohm is required to magnitudes will not cause spurious Initial Dielectric Strength — obtain the maximum time for all ranges. operation of affect function and accuracy. Between Terminals and Mounting — To determine the actual resistance 3,000VAC rms. Operating <0.1 ms <1 ms needed to obtain the required time delay, Voltage Between Input and Output — use the following formula: 1,500VAC rms. 12, 860V* 208V* 24 VAC/VDC (T - T ) REQ MIN R = x 1,000,000 ohms T 120 VAC/VDC 2,580V 2,150V* T - T MAX MIN * Min. source impedance of 100 ohms. Accuracy — Product Facts Repeat Accuracy — ±1% Current Drain — Less than 5mA. Overall Accuracy — ±2% at n One shot (latching interval) Environmental Data R = 1 megohm timing mode Temperature Range — Reset Time — 50 ms, max. Storage — -40°C to +85°C n Reliable solid state timing Operating — -40°C to +65°C circuitry Mechanical Data n Excellent transient Mounting — Panel mount with one protection #8 screw. n Compact design 1.25 Termination — 0.250 in (6.35) quick 2.00 (31.8) n Flame retardant, solvent connect terminals. (50.8) .885 resistant housing (22.5) Weight — 4 oz. (112g) approximately n File E60363, File LR33434 2.00 R (50.8) R .170 DIA (4.32) .250 (6.35) X .032 (.813) 12 QUICK CONNECTS ACCEPTS #8 SCREW Outline Dimensions START POLARITY SHOWN SWITCH FOR DC MODELS An external resistance of 1 megohm is required to obtain the maximum time 1 5 LOAD 7 6 for all ranges. To determine the actual R resistance needed to obtain the required 2 4 time delay, use the following formula: INPUT (T - T ) REQ MIN VOLTAGE R = x 1,000,000 ohms T 3 T - T MAX MIN Wiring Diagram Ordering Information VTM4 A CD || | Series VTM4 Input Voltage Time Range One Shot A = 120VAC/VDC CD = 0.5 - 10 sec. (Latching Interval) E = 24VAC/VDC DD = 3 - 60 sec. Timing Module Q = 12VAC/VDC FD = 0.5 - 10 min. Users should thoroughly review the GD = 3 - 60 min. technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and Authorized distributors are likely to stock the following: review them to ensure the product meets the requirements for a given application. None at present. 12–47 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays VTM7 Series, Repeat Cycle, Timing Module Timing Specifications Output Switch Data Input Data @ 25°C Timing Mode — Repeat Cycle Arrangement — Solid state 1 Form A Voltage (±10%) — 12 VAC/VDC, (SPST-NO) 24VAC/VDC, 120 VAC/VDC. Timing Ranges — 0.5 to 10 / 3 to 60 sec.; 3 to 60 min. Rating — 1A, inductive, at nominal Power Requirement — 4W with operating voltage. rated load Timing Adjustment — External resistor or potentiometer. An external Expected Electrical Life — Transient Protection — resistance of 1 megohm is required to 10,000,000 operations at rated load. Non-repetitive transients of the following obtain the maximum time for all ranges. magnitudes will not cause spurious Initial Dielectric Strength — To determine the actual resistance operation of affect function and accuracy. Between Terminals and Mounting — needed to obtain the required time delay, 3,000VAC rms. Operating <0.1 ms <1 ms use the following formula: Voltage Between Input and Output — (T - T ) 1,500VAC rms. 12, REQ MIN 860V* 208V* R = x 1,000,000 ohms T 24 VAC/VDC T - T MAX MIN 120 VAC/VDC 2,580V 2,150V* Accuracy — * Min. source impedance of 100 ohms. Repeat Accuracy — ±1% Product Facts Overall Accuracy — ±2% at Current Drain — Less than 5mA. R = 1 megohm n Repeat cycle timing mode Environmental Data Reset Time — 500 ms n Independently adjustable Temperature Range — Storage — -40°C to +85°C On and Off times Operating — -40°C to +65°C n Reliable solid state timing Mechanical Data circuitry Mounting — Panel mount with one n Excellent transient 1.25 #8 screw. 2.00 protection (31.8) Termination — 0.250 in (6.35) quick (50.8) .885 n Compact design connect terminals. (22.5) Weight — 4 oz. (112g) approximately n Flame retardant, solvent 2.00 resistant housing (50.8) n File E60363, File LR33434 R R .250 (6.35) X .032 (.813) .170 DIA (4.32) ACCEPTS #8 SCREW QUICK CONNECTS Outline Dimensions R POLARITY SHOWN t FOR DC OFF MODELS An external resistance of 1 megohm 5 LOAD 1 is required to obtain the maximum time 7 6 for all ranges. To determine the actual R resistance needed to obtain the required 2 4 ON time delay, use the following formula: INPUT VOLTAGE (T - T ) REQ MIN 3 R = x 1,000,000 ohms T T - T MAX MIN Wiring Diagram Ordering Information VTM7 A CD || | Series VTM7 Input Voltage Time Range Repeat Cycle A = 120VAC/VDC CD = 0.5 - 10 sec. Timing Module E = 24VAC/VDC DD = 3 - 60 sec. Q = 12VAC/VDC GD = 3 - 60 min. Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and Authorized distributors are likely to stock the following: review them to ensure the product meets the requirements for a given application. None at present. 12–48 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays Specialty Relays VTMA1 Series, On-Delay Timing Module, With Internal Potentiometer Timing Specifications Output Switch Data Input Data @ 25°C Timing Mode — On-Delay Arrangement — Solid state 1 Form A Voltage (±10%) — 120VAC/VDC (SPST-NO) (unfiltered DC must be full-wave Timing Ranges — rectified) or 24 to 240 VAC/VDC. VTMA1ULA only — 24 to 480 sec. Rating — 1A, inductive, at nominal All others — 0.5 to 10 / 3 to 60 /15 to operating voltage. Power Requirement — 250mW 300 sec.; 3 to 60 min. during timing; 3W, max. after time out. Expected Electrical Life — Timing Adjustment — 10,000,000 operations at rated load. Transient Protection — Internal potentiometer Non-repetitive transients of the following Initial Dielectric Strength — magnitudes will not cause spurious Accuracy — Between Terminals and Mounting — operation of affect function and accuracy. Repeat Accuracy — ±5% 3,000VAC rms. Overall Accuracy — Between Input and Output — Operating <0.1 ms <1 ms Voltage Max. Time: –0%, +10%. 1,500VAC rms. Min. Time: –30%, +10%. 24 VAC/VDC 860V* 208V* 120/ Reset Time — 250 ms, max., before 2,580V 2,150V* 240 VAC/VDC time-out; 10 ms, max., after time-out. * Min. source impedance of 100 ohms. Product Facts Current Drain — 2mA, Max. n On-delay timing mode Environmental Data Temperature Range — n Discrete voltage or Storage — -40°C to +85°C universal type Operating — -40°C to +65°C n Internal potentiometer for Mechanical Data timing adjustment Mounting — Panel mount with one n Reliable solid state timing #8 screw. circuitry Termination — 0.250 in (6.35) quick connect terminals. n Excellent transient 2.00 1.25 Weight — 4 oz. (112g) approximately protection (50.8) (31.8) .388 .885 (9.85) n Flame retardant, solvent (22.5) resistant housing TIME DELAY n File E60363, File LR33434 .427 ADJUSTMENT (10.8) R 12 R 2.00 .170 DIA (50.8) (4.32) ACCEPTS #8 SCREW .250 (6.35) X .032 (.813) INPUT LOAD VOLTAGE QUICK CONNECTS L1 L2 Outline Dimensions and Wiring Diagram Ordering Information Part Number Time Range Input Voltage VTMA1ACA 0.5 to 10 sec. 120VAC or VDC VTMA1ADA 3 to 60 sec. VTMA1ULA 24 to 480 sec. 24-240VAC or VDC Users should thoroughly review the technical data before selecting a product Authorized distributors are likely to stock the following: part number. It is recommended that user None at present. also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. 12–49 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change. Specialty Relays VTMR1 Series, On-Delay Timing Module, With Internal Potentiometer, Relay Output Timing Specifications Output Switch Data Input Data @ 25°C Timing Mode — On-Delay Arrangement — 1 Form C (SPDT) Voltage (±10%) — 120VAC/VDC Timing Ranges — 15 to 300 sec. Rating — 8A, resistive, at nominal Power Requirement — 3.5VA max. operating voltage. during timing; 3W, max. after time out. Timing Adjustment — Internal potentiometer Expected Mechanical Life — Transient Protection — 10,000,000 operations Non-repetitive transients of the following Accuracy — magnitudes will not cause spurious Repeat Accuracy — Expected Electrical Life — operation of affect function and accuracy. ±5% max. (0.25% typ.) 100,000 operations Overall Accuracy — Operating Initial Dielectric Strength — <0.1 ms <1 ms Voltage Max. Time: –0%, +10%. Between Terminals and Mounting — Min. Time: –30%, +10%. 120 VAC/VDC 2,580V 2,150V* 3,000VAC rms. Reset Time — 250 ms, max. Between Input and Output — * Min. source impedance of 100 ohms. 1,500VAC rms. Current Drain — 30mA, Max. Environmental Data Temperature Range — Product Facts Storage — -40°C to +70°C Operating — -40°C to +70°C n On-delay timing mode Mechanical Data n 8A SPDT relay output Mounting — Panel mount with one n Internal potentiometer for #8 screw. timing adjustment Termination — 0.250 in (6.35) quick connect terminals. n Reliable solid state timing Weight — 4 oz. (112g) approximately circuitry n Excellent transient 2.00 protection (50.8) .763 OUTPUT RELAY (19.4) n Flame retardant, solvent .278 (7.06) resistant housing OUTPUT n File E60363, File LR33434 RELAY .286 TIME R (7.26) R DELAY ADJUST 2.00 (50.8) INPUT VOLTAGE .885 .170 DIA (22.5) (4.32) .250 (6.35) X .032 (.813) 1.25 ACCEPTS QUICK CONNECTS (31.8) #8 SCREW Outline Dimensions and Wiring Diagram Ordering Information Part Number Time Range Input Voltage VTMR1AEA 15 to 300 sec. 120VAC Authorized distributors are likely to stock the following: None at present. Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. 12–50 Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com Specifications subject UK: +44 800 267 666 www.te.com to change.

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the 1472962-1?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Time Delay Relay 125VDC 10A DPDT(114.8x82.6x78.5)mm Panel 1-1437457-3

product

Time Delay Relay 125VDC 120VAC 10A DPDT(50x50x83)mm Socket 1-1437467-1

product

Time Delay Relay 24VDC 24VAC 10A DPDT (( 50mm 50mm 83mm)) Socket 1-1437468-3

product

Time Delay Relay 125VDC 120VAC 10A DPDT (( 38mm 35mm 77mm)) Socket 1-1437476-7

product

Time Delay Relay 28VDC 10A DPDT(63.5x38.6x123.9)mm Panel 1423152-2

product

Time Delay Relay 125VDC 10A DPDT(63.5x38.6x123.9)mm Chassis 1423154-1