Electronics Finder chervon right Manufacturers chervon right T chervon right TE CONNECTIVITY chervon right 1534858-1
About product Specifications Datasheet FAQ

TE CONNECTIVITY 1534858-1

Image of TE CONNECTIVITY 1534858-1

Description

Engineering Development Kit Includes 100 Cable Connectors , Hand Crimping Tool, Extraction Tool And Insulation Stripper
1534858-1

Part Number

1534858-1

Price

Request Quote

Manufacturer

TE CONNECTIVITY

Lead Time

Request Quote

Category

Tools and Supplies »  Component Kits

Specifications

Manufacturer

TE Connectivity

Manufacturers Part #

1534858-1

Industry Aliases

1534858-1

Sub-Category

Component Kits

Brand

AMP

Factory Pack Quantity

1

Datasheet

pdf file

DDEController?Action=showdoc&DocId=Catalog+Section%7F889753-3_SOLARLOK_interconnection_system%7F0608%7Fpdf%7FEnglish%7FENG_CS_889753-3_SOLARLOK_interconnection_system_0608.pdf

3215 KiB

Extracted Text

1-SOLARLOK Cover, GB.qxd 19.05.2008 19:47 Uhr Seite 1 RoHS Ready SOLARLOK Interconnection System OBSOLETE NOT the LATEST REVISION 1-SOLARLOK Cover, GB.qxd 19.05.2008 19:47 Uhr Seite 2 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Table of Contents The SOLARLOK Concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Large Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Large Junction Box – Parallel Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Medium Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Small Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Mini Junction Box – Serial Interconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Cable Coupler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 T-Branch Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 DC/AC Converter Receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 AC Inverter Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Solar Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Solar Cable, 1-Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Field Wiring, Switching and Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Wiring Example with Extension Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 SolKlip™ – Ground Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Interconnection Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Application Tooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Assembly and Installation Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Numerical Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Restriction on the Use of Hazardous Substances (RoHS) . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Engineering Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Product Information Center (PIC) Tyco Electronics Online Our PIC team are there to help with any further questions. With our experienced employees in the Product Information Center Internet Homepage: (PIC) we can offer you a reliable source of information and support www.tycoelectronics.com for your technical queries. To contact your local Tyco Electronics subsidiary, Electronic Internet Catalog: please refer to the address page at the back of this catalog. http://catalog.tycoelectronics.com Our website is more than an Internet guide. It is constantly being added to and is an innovative and interactive source for applications Product und Machine Literature tips, product updates and technical information of all types. With our innovative StepSearch software, which has been perfected over a Order quickly and easily by fax: period of several years you can conveniently surf your way through all our products. For Fax No. see address page entry for your specific region. A large product range has extensive product literature. You can request flyers, catalogs and brochures for each of the product sectors of relevance to you. All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:22 Uhr Seite 1 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 The SOLARLOK Concept System Features Junction Box ■ Variable wiring options ■ Easily accessible ■ Simple, fast and cost-effective assembly ■ Flat, low profile design ■ High current carrying capacity ■ Good thermal balance ■ Connectorized or direct wire configurations ■ Up to four outputs possible ■ Up to six internal rails ■ Customer-specific solutions ■ TÜV and UL approved Connector ■ Simple on-site processing ■ Mating safety provided by keyed housings ■ Semi-automatic assembly capability possible ■ Multiple plugging and unplugging cycles ■ Accomodates solar cable with different insulation diameters Tyco Electronics will be con- The male and female cable Simple and Reliable tributing to the establishment of coupler was designed for high ■ High current carrying capacity System Interconnection of this environmentally-friendly voltage and high current-carrying ■ Wide temperature operating Individual Solar Modules technology with the introduction capacity in addition to the well- range Right to the DC/AC of its SOLARLOK connector established IP 67 sealing require- ■ TÜV and UL approved Converters system. ment in the photovoltaic industry. Mating safety is provided by Market expansion of the formerly SOLARLOK delivers a flexible polarity keyed housings, fully regulated energy supply sector, system solution for easy and Solar Cable shrouded contacts, reliable high increased global environmental reliable interconnections from cycle life, and squeeze to release ■ Dual wall insulation awareness and governments photovoltaic modules to the connection system. In addition, ■ Electron beam cross-linked committing themselves to more DC/AC converter. The entire a wide temperature range and ful- ■ Excellent resistance to U.V., stringent environmental targets system concept is based on cost- fillment of worldwide standards water, ozone, fluids, salt, have opened up new opportunities effective and reliable processing for photovoltaic connection general weathering for the photovoltaic industry. of individual interconnection systems complement the robust ■ Excellent resistance to abrasion system components. This Having served a niche market product specification. ■ Halogen free, flame retardant, significantly reduces installation in the past, the photovoltaics low toxicity costs of the solar energy system. The design of the male and industry now has the opportunity ■ Very low smoke emissions female receptacle for the junction to move into mass production, The junction box concept is box and the DC/AC converter ■ Excellent flexibility and realizing economies of scale and based on a flexible, open system follow the cable coupler “click stripping performance gaining a greater market share structure, which allows serial as philosophy” for quick and secure ■ Different cable diameters of the world’s energy mix. well as parallel interconnection mating even in difficult mounting ■ Operating Temperature from via direct wire connect or positions. –40 °C up to +120 °C separable connectors. Within the ■ Voltage Rating up to 2600 V DC junc-tion box, up to six termina- If required by the customer, the ■ IEC 60228 Class 5 (stranded tion places rails are available for junction box can be delivered tin plated copper and flexible) photovoltaic foil connection. pre-configured with diodes, ■ TÜV certified acc. to jumpers, plug connectors, and 2Pfg 1169/08.2007 solar cable pigtails. ■ UL certified All specifications subject to change. Consult Tyco Electronics for latest specifications. 1 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:22 Uhr Seite 2 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Large Junction Box – Serial Interconnection W: 150 mm H: 25 mm SERIAL INTERCONNECTION Interconnection Options Part Package Contact Configuration Plug Connector Diodes Number Quantity Rails Direct Wire Plus Keyed Minus Keyed 1-1394723-6 20 oo oooooo 2-1394723-6 20 oo oooooo oooo 0-1394723-4 20 oo oooooo 0-1394723-3 20 o o oooooo 2 All specifications subject to change. Consult Tyco Electronics for latest specifications. D: 150 mm 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:22 Uhr Seite 3 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Large Junction Box – Parallel Interconnection W: 150 mm H: 25 mm PARALLEL INTERCONNECTION Interconnection Options Part Package Contact Configuration Plug Connector Diodes Number Quantity Rails Direct Wire Plus Keyed Minus Keyed 1394723-5 20 o o oooooo 1394723-6 20 oooo oooooo 1394723-9 20 oooo oooooo All specifications subject to change. Consult Tyco Electronics for latest specifications. 3 D: 150 mm 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:22 Uhr Seite 4 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Medium Junction Box – Serial Interconnection W: 115 mm H: 22.5 mm SERIAL INTERCONNECTION Interconnection Options Part Package Contact Configuration Plug Connector Diodes Number Quantity Rails Direct Wire Plus Keyed Minus Keyed 1740699-1 60 oo oooo ooo SL1010 ✱ 1740699-6 35 oo oooo ooo SL1010 1740700-1 60 o o oooo ooo SL1010 ✱✱ 1740700-3 35 o o oooo ooo SL1010 1740971-1 60 oo oooo ooo SL1515 ✱ 1740971-2 35 oo oooo ooo SL1515 1740972-1 60 o o oooo ooo SL1515 ✱✱ 1740972-3 35 o o oooo ooo SL1515 ✱✱ 2 ) Junction Box Assembly with two 100 cm long 4.0 mm black solar cable and plug connector. ✱✱ 2 ) Junction Box Assembly with one 200 cm long 4.0 mm black solar cable and two plug connectors. 4 All specifications subject to change. Consult Tyco Electronics for latest specifications. D: 135 mm 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 5 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Medium Junction Box – Serial Interconnection (continued) W: 115 mm H: 22.5 mm SERIAL INTERCONNECTION Interconnection Options Part Package Contact Configuration Plug Connector Diodes Number Quantity Rails Direct Wire Plus Keyed Minus Keyed ooo SL1010 0-1740657-7 60 oo oooo ooo SL1515 ooo SL1010 ✱ 0-1740657-8 35 oo oooo ooo SL1515 ooo SL1010 0-1740658-1 60 o o oooo ooo SL1515 ooo SL1010 ✱✱ 0-1740658-3 35 o o oooo ooo SL1515 0-1740657-9 60 oo oooo ooo SL1515 ✱ 1-1740657-0 35 oo oooo ooo SL1515 0-1740658-4 60 o o oooo ooo SL1515 ✱✱ 0-1740658-5 35 o o oooo ooo SL1515 ✱✱ 2 ) Junction Box Assembly with two 100 cm long 4.0 mm black solar cable and plug connector. ✱✱ 2 ) Junction Box Assembly with one 200 cm long 4.0 mm black solar cable and two plug connectors. All specifications subject to change. Consult Tyco Electronics for latest specifications. 5 D: 135 mm 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 6 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Small Junction Box – Serial Interconnection W: 90 mm H: 22 mm SERIAL INTERCONNECTION Interconnection Options Part Package Contact Configuration Plug Connector Diodes Number Quantity Rails Direct Wire Plus Keyed Minus Keyed 1740220-4 80 oo ooo 1740220-2 80 oo ooo oo ✱ ✱ 1740425-3 48 oo ooo oo 1740220-3 80 oo ooo 1740220-1 80 oo ooo oo ✱✱ ✱✱ 1740425-1 48 oo ooo oo ✱✱ 2 ) Junction Box Assembly with two 70 cm long 4.0 mm black solar cable and plug connector. ✱✱ 2 ) Junction Box Assembly with two 85 cm long 4.0 mm black solar cable and plug connectors. 6 All specifications subject to change. Consult Tyco Electronics for latest specifications. D: 138 mm 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 7 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Small Junction Box – Serial Interconnection (continued) W: 90 mm H: 22 mm SERIAL INTERCONNECTION Interconnection Options Part Package Contact Configuration Plug Connector Diodes Number Quantity Rails Direct Wire Plus Keyed Minus Keyed 0-1418867-2 80 oo ooo 0-1418867-5 80 oo ooo oo ✱ 1-1418867-3 48 oo ooo oo 0-1418867-1 80 o o ooo 0-1418867-6 80 o o ooo oo ✱✱ 1-1418867-2 48 o o ooo oo ✱✱ 2 ) Junction Box Assembly with one 140 cm long 4.0 mm black solar cable and two plug connectors. ✱✱ 2 ) Junction Box Assembly with one 170 cm long 4.0 mm black solar cable and two plug connectors. All specifications subject to change. Consult Tyco Electronics for latest specifications. 7 D: 138 mm 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 8 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Mini Junction Box – Serial Interconnection W: 76 mm H: 19 mm SERIAL INTERCONNECTION Part Package Contact Rail Contact Configuration Direct Wire Diodes Number Quantity Shape Rails ✱ 1740863-1 80 Straight oo oo o ✱ 1740863-2 80 Right-Angle oo oo o ✱ 2 ) Junction Box Assembly with two 85 cm long 4.0 mm black solar cable and plug connector. 8 All specifications subject to change. Consult Tyco Electronics for latest specifications. D: 111 mm 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 9 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Cable Coupler Female Cable Coupler Male Cable Coupler Wire Size Package 2 (mm ) Quantity Plus Keyed Minus Keyed Plus Keyed Minus Keyed 2.5 0-1394462-1 0-1394462-2 0-1394461-1 0-1394461-2 100 4.0 0-1394462-3 0-1394462-4 0-1394461-3 0-1394461-4 100 6.0 5-1394462-5 5-1394462-6 6-1394461-5 6-1394461-6 100 Male Cable Coupler Wire Size Package Not Keyed, only for Junction Male Cable Coupler 2 (mm ) Quantity Box Serial Interconnection 2.5 6-1394461-1 100 4.0 6-1394461-2 100 6.0 6-1394461-4 100 Cable Coupler with Connector Latch Locking Clip Connector Latch Package Locking Clip Quantity 0-1534226-1 100 All specifications subject to change. Consult Tyco Electronics for latest specifications. 9 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 10 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 T-Branch Connector Parallel Interconnection using T-Branch Connector (Male-to-Male) T-Branch Connector Package Part Number Quantity Plus Keyed Minus Keyed o 1534611-1 20 o 1534611-2 20 Parallel Interconnection using T-Branch Connector (Female-to-Male) T-Branch Connector Package Part Number Quantity Plus Keyed Minus Keyed o 1740277-1 20 o 1740277-2 20 10 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 11 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 DC/AC Converter Receptacle O-Ring and Metal Nut Flat Seal and Plastic Nut With Cover Wire Size Keying Package 2 2 Part Number Remarks 2.5 mm 4.0 mm Quantity Plus Minus (AWG 14) (AWG 12) oo 1394738-1 100 oo 1394738-2 100 O-Ring and Metal Nut oo 1394738-3 100 oo 1394738-4 100 oo 1740210-1 100 oo 1740210-2 100 Flat Seal and Plastic Nut – Black oo 1740210-3 100 oo 1740210-4 100 oo 1740210-7 100 Flat Seal and Plastic Nut – Red oo 1740210-8 100 Flat Seal and Plastic Nut – Blue oo 1740210-9 100 Flat Seal and Plastic Nut – Red oo 1-1740210-0-0 100 Flat Seal and Plastic Nut – Blue oooo 1394739-1 100 Cover All specifications subject to change. Consult Tyco Electronics for latest specifications. 11 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 12 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 AC Inverter Connector Product Facts ■ Current Rating: 30 A ■ Voltage Rating: 400 V ■ Protection Degree: IP67 (mated) ■ No. of Positions: 5 Poles ■ Temperature Range: –40 °C up to +50 °C ■ Wire Size Range: 2 2.5–6.0 mm ■ Approvals: • VDE certified • UL pending Cable Length Package Configuration 5 Pole 200 mm Metall Nut Plastic Nut Part Number Quantity 2 (5 x 4 mm ) Receptacle ooo 1740483-1 24 Receptacle oo o 1740483-2 24 Header o 1740479-1 24 Assembly ooo 1740493-1 24 Assembly oo o 1740493-2 24 12 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 13 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Solar Cable Product Facts ■ Dual wall insulation ■ Electron beam cross-linked ■ Excellent resistance to UV, water, ozone, fluids, salt, general weathering ■ Excellent resistance to abrasion ■ Halogen free, flame retardant, low toxicity ■ Very low smoke emissions ■ Excellent flexibility and stripping performance 2 ■ Wire size from 2.5 mm 2 up to 6.0 mm As part of expanding the The flexible, dual wall, halogen In addition, it has excellent SOLARLOK Product Line, free and cross linked solar resistance to abrasion and Tyco Electronics has specified wire offers long term stability temperature extremes. a wire that is designed to meet and TÜV approval. The wire has a high dielectric the harsh environmental Its outstanding features in- withstand voltage and with conditions typical in the wiring clude: high resistance against its fine-stranded, tin plated of photovoltaic installations. environmental conditions like copper conductor, it is easy humidity, UV-radiation and to handle and to strip. ozone. Standards Material and Finish Mechanical Features Electrical Features Approval: Conductor: Max. Conductor Temperature Voltage Rating U /U: O • IEC 60228 Class 5 Stranded tin plated copper Continuous: +120 °C 1800/3000 V AC / 2600 V DC (stranded tin plated copper At Short Circuit: +250 °C Insulation: Test Voltage for 5 Minutes: and flexible); Min. Operating Temperature Electron beam cross-linked 6000 V • TÜV certified acc. to Polyolefin Free Installation: –25 °C 2Pfg 1169/08.2007 Max. Current Carrying Capacity Fixed Installation: –40 °C Sheath: (Free in Air): Wire Size Range: Electron beam cross-linked 36 A up to 116 A (size dependent) 2 halogen free Polyolefin 2.5 mm (AWG 14), 2 4.0 mm (AWG 12), Color: 2 6.0 mm (AWG 10) Black, blue, red Min. Bending Radius: 5 x cable wire diameter, fixed installation All specifications subject to change. Consult Tyco Electronics for latest specifications. 13 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 14 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Solar Cable, 1-Pole Tyco Electronics Solar Cable, 1-Pole ■ TÜV approved ■ UL approved Wire Size Range Outer Diameter Package Quantity Approbation Color Part Number 2 (mm ) (AWG) (mm) (Inch) (m) (Feet) TÜV 0-956297-4 500 – o Black 1-956297-4 100 – o 0-956297-5 500 – o 2.5 – 5.1 0.20 Red 1-956297-5 100 – o 0-956297-6 500 – o Blue 1-956297-6 100 – o 0-956298-4 500 – o Black 1-956298-4 100 – o 0-956298-5 500 – o 4.0 – 5.7 0.22 Red 1-956298-5 100 – o 0-956298-6 500 – o Blue 1-956298-6 100 – o 0-956299-4 500 – o Black 1-956299-4 100 – o 0-956299-5 500 – o 6.0 – 6.2 0.24 Red 1-956299-5 100 – o 0-956299-6 500 – o Blue 1-956299-6 100 – o Wire Size Range Outer Diameter Package Quantity Approbation Color Part Number 2 (mm ) (AWG) (mm) (Inch) (m) (Feet) UL ✱ -1986166-2 – 500 o – 14 – 0.17 Black ✱ -1986166-3 – 2500 o ✱ -1986165-2 – 500 o – 12 – 0.19 Black ✱ -1986165-3 – 1500 o ✱ -1986164-2 – 500 o – 10 – 0.21 Black ✱ -1986164-3 – 1000 o ✱ ) Technical Data upon request. 14 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 15 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Field Wiring, Switching and Protection Product Features Switching Collecting Protecting ■ Modular product concept ■ One- / two-pole switches ■ Current up to 80 A DC ■ Voltage up to 1000 VDC ■ Compact, standardized design ■ Proven quality ■ One- / two-pole switch ■ 1 to 10 strings input ■ Lightning protection ■ Main switch function ■ Cable cross section 2 up to 10 mm ■ Lockable ■ SOLARLOK connectors ■ Current up to 63 A DC ■ Various cable glands ■ Voltage up to 900 V Uoc ■ Current up to 80 A DC ■ Voltage up to 1000 V DC Your Solution The photovoltaic integrator looks for best fit solutions to wire various types and sizes of solar generators. The new product concept from Tyco Electronics provides this flexibility to photovoltaic integrators. The modular product can be comprised of a switch, lightning protection, fuses or any combination of these or other commonly available components. We can customize a product to fit your specific application. Please contact us with your requirements. All specifications subject to change. Consult Tyco Electronics for latest specifications. 15 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 16 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Wiring Example with Extension Cables 2 3 Clearance (e.g. Roof Window) 2 2 1 Male Cable Coupler (+) Female Cable Coupler (+) 1 1394461-3 1394462-3 Male Cable Coupler (–) Female Cable Coupler (–) 2 1394461-4 1394462-4 Female Cable Coupler (+) Female Cable Coupler (+) 3 1394462-3 1394462-3 Inverter 2 Configuration Example at 4.0 mm . Cable Assembly Part Numbers for Cable Length Cable Assembly Version 1 m 3 m 5 m 10 m 20 m Wire Size: 2 4.0 mm 1 2-1987376-1 2-1987376-2 2-1987376-3 2-1987376-4 2-1987376-5 Color: 2 1-1987376-1 1-1987376-2 1-1987376-3 1-1987376-4 1-1987376-5 Black 3 2-1987376-1 2-1987376-2 2-1987376-3 2-1987376-4 2-1987376-5 More variants (cable length, wire diameter, color) upon request. 16 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 17 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Wiring Example with Extension Cables (continued) 5 5 3 Clearance (e.g. Roof Window) 4 2 1 Male Cable Coupler (+) Female Cable Coupler (+) 1 1394461-3 1394462-3 Male Cable Coupler (–) Female Cable Coupler (–) 2 1394461-4 1394462-4 Female Cable Coupler (+) Female Cable Coupler (+) 3 1394462-3 1394462-3 Inverter Female Cable Coupler (–) Female Cable Coupler (–) 4 1394462-4 1394462-4 Female Cable Coupler (–) Female Cable Coupler (+) 5 1394462-4 1394462-3 2 Configuration Example at 4.0 mm . Cable Assembly Part Numbers for Cable Length Cable Assembly Version 1 m 3 m 5 m 10 m 20 m Wire Size: 2 4.0 mm 1 2-1987376-1 2-1987376-2 2-1987376-3 2-1987376-4 2-1987376-5 Color: 2 1-1987376-1 1-1987376-2 1-1987376-3 1-1987376-4 1-1987376-5 Black 3 2-1987376-1 2-1987376-2 2-1987376-3 2-1987376-4 2-1987376-5 4 3-1987376-1 3-1987376-2 3-1987376-3 3-1987376-4 3-1987376-5 5 4-1987376-1 4-1987376-2 4-1987376-3 4-1987376-4 4-1987376-5 More variants (cable length, wire diameter, color) upon request. All specifications subject to change. Consult Tyco Electronics for latest specifications. 17 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 18 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 SolKlip™ – Ground Clip Product Features ■ Self-tapping screw ■ Quick and easy mounting ■ Four-point contact to wire ■ Low interface resistance ■ Toolless termination ■ Re-terminateable up to 5 times ■ UV resistant ■ Weather-proof ■ UL approved ■ RoHS compliant Tyco Electronics’ newest Termination times are meas- With a tensile strength of up innovation provides the photo- ured in seconds using the to 36 kg, the UV-resistant voltaic integrator with a solu- pre-mounted Tyco Electronics enclosure provides a secure tion for grounding PV panels SolKlip thereby saving time termination even in roughest and mounting frames. The and reducing wiring costs environmental and assembly Tyco Electronics SolKlip brings substantially. The four-point conditions. As an added a new ground connection wire contact inherent in the benefit, the connection can solution to the market by the design optimizes grounding be opened and re-terminated utilizing well-known insulation performance and provides again up to five times. displacement termination protection against contact Retrofitting the Tyco Electronics technology. problems due to its low inter- SolKlip on panels or frames face resistance. Existing solutions typically can be done at any time by require the use of ring tongue The Tyco Electronics SolKlip simply by drilling mounting hole crimp terminals which have to can be used with un-insulated in the frame and attaching be crimped first at a specific copper wires from 12 AWG to the terminal to the frame using location on the wire, a hole is 10 AWG. The retained-force the integrated, self-tapping then drilled into the mounting nature of the contact provides screw. This ensures a secure surface, and the product is a robust interface that mini- connection with the panel finally mounted on the frame mizes vibration or thermally and/or frame. with a separate thread forming induced termination problems The patent-pending Tyco or self-tapping screw. The that often occur with traditional Electronics SolKlip ground new Tyco Electronics SolKlip ground-screw connections. terminal supplements the provides an extremely simpli- Termination of the wire is safely existing Tyco Electronics fied solution for terminating a and easily accomplished tool- SOLARLOK product portfolio continuous-run ground wire. lessly by simply inserting the and offers the electrician yet wire and closing the cover. another valuable component for simple and fast wiring of a PV-system. 18 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 19 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 SolKlip™ – Ground Clip (continued) 3 Easy Steps to – + – + – + Ground Your PV System Yesterday • Screw • Screwdriver • Washer • Drill • Lock Washer • Pliers Insert ... • Ring Tongue – – – + + + ... Push ... Today • SolKlip ... Ready! Click Click Click Description Electrical Standards and Specifications Mechanical SolKlip ground clips are designed The electrical performance of SolKlip Grounding Clip: The mechanical properties of for solar panel grounding appli- this product will meet the tough UL 467 pending, a requirement this product will meet the tough cations using solid un-insulated requirements of photovoltaic for UL 1703 solar panel listing. requirements for grounding copper 10 AWG and 12 AWG. grounding applications. applications layed down in the UL 486A-B pending, also a UL requirements. requirement as part of the UL 1703 approval listing. Applications Product Offering & Dimensions Solar panels and related products SolKlip for Solar Grounding that require grounding for safety Part No. 1954381-1 to handle Materials reasons. 12–10 AWG solid, un-insulated Housing: ground wire. Applications include: wire Durable PPT jumpers between solar panels, Contact: solar roof tiles and between Application Tooling High conductivity copper alloy panels and the AC/DC inverters. No special tooling required. All specifications subject to change. Consult Tyco Electronics for latest specifications. 19 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 20 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Interconnection Examples Serial Interconnection for Junction Boxes with Cable Glands 2 (4.0 mm Wiring) 1394462-4 6-1394461-2 1394461-4 1394462-3 1394462-3 1394462-4 1394738-4 1394738-3 DC/AC Converter 20 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 21 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Interconnection Examples (continued) Serial Interconnection for Junction Boxes with Plug Connectors 2 (4.0 mm Wiring) 1394462-4 1394462-3 1394462-3 1394462-4 1394462-4 1394462-3 1394738-4 1394738-3 DC/AC Converter All specifications subject to change. Consult Tyco Electronics for latest specifications. 21 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 22 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Application Tooling Hand Crimping Tool Cable Assembly Tooling incl. Vario Crimp Head and Locator Part Numbers 2 1-1579004-1 (1.5 + 2.5 mm ) 2 1-1579004-2 (4.0 + 6.0 mm ) Vario Crimp Head 2 7-1579001-8 (1.5 + 2.5 mm ) 2 7-1579001-9 (4.0 + 6.0 mm ) Hand Crimping Tool incl. Vario Crimp Head and Locator Part No. 1579004-8 2 (for 1.5 + 2.5 + 4.0 + 6.0 mm ) Die Set Part No. 6-1579001-6 2 (for 1.5 + 2.5 + 4.0 + 6.0 mm ) Extraction Tool suitable for all wire sizes Part No. 1102855-3 Insulation Stripper includes length stop for all wire 2 2 2 sizes: 1.5 mm , 2.5 mm ,4.0 mm 2 and 6.0 mm . Suitable for Tyco Electronics Solar Cable. Part No. 4-1579002-2 Adapter for Vario Crimp Head: SOLARLOK Part No. 1579000-4 Electric Terminator CS 200 Base Machine: Part No. 539630-1 Vario Crimp Head 2 (1.5 and 2.5 mm ): Part No. 7-1579001-8 Vario Crimp Head 2 (4.0 and 6.0 mm ): Part No. 7-1579001-9 Vario Crimp Head (AWG 10): Part No. 8-1579001-2 Vario Crimp Head (AWG 12): Part No. 5-1579001-5 Vario Crimpkopf (AWG 14): Part No. 5-1579001-4 22 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 23 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Application Tooling (continued) Wire Spring Clamp Tool Junction Box Assembly Tooling Part No. 1579007-2 Dioden / Jumper Spring Clamp Tool Part No. 1579007-5 Foil Spring Clamp Tool Part No. 1579007-3 Large Box Part No. 1740969-1 Medium Box Part No. 1740969-2 Small Box Kit includes the following parts: Field Service Kit ■ 100 Cable Coupler Part No. 1534858-1 (Housings, Plus and Minus (Metric Wire) coded) ■ Crimp Contacts 2 (4.0 and 6.0 mm ) ■ Strain Relief ■ Seals ■ Hand Crimp Tool: Part No. 1-1579004-2 ■ Extraction Tool: Part No. 1102855-3 ■ Insulation Stripper: Part No. 4-1579002-2 All specifications subject to change. Consult Tyco Electronics for latest specifications. 23 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 24 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Assembly and Installation Guidelines Table of Contents Page SOLARLOK Plug Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 1. General Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 2. Termination of the Cable Wires / Crimping of the Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 3. Handling of the Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 3.1 Selection of Sealing Grommet for Cable Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 3.2 Connector Latching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3.3 Disconnecting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3.4 DC/AC Converter Receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 4. Application Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 5. Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 6. Tooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 SOLARLOK Plug Connector Attention: This connector is to be used only to interconnect firmly fixed cables. Do not disconnect under load. Current path should only be disconnected using approved disconnect devices. Cable assemblies shall be labeled with Part No. 1394470-1. To protect against shock, ensure that conductors and their associated connectors are separated from opposite polarity components. 1. General Comments Any kind of pollution (dust, oil, humidity, etc.) during the assembly process or to the unmated connector can degrade contact and connector performance. This applies in particular to the seals and the crimping of the contacts. A clean assembly environment is therefore essential. 2. Termination of the SOLARLOK connectors use different crimp contacts for various wire gauges. 2 2 2 2 2 Cable Wires and Crimping Possible wire gauges are 1.5 mm , 2.5 mm , 4.0 mm , 5.3 mm und 6.0 mm resp. of the Contacts AWG 16, AWG 14, AWG 12 and AWG 10. The tools to be used are selected based upon the wire gauge. For the application specification, please refer to specification # 114-74013. 3.1 Handling of the Connectors 3.1 Selection of Use only appropriate wire gauges. 3.1 Sealing Grommet Besides the standard seal/pinch ring combination further five different seals are available. 3.1 for Cable Connectors ■ 4.0 mm grommet inner diameter (for insulation diameter from 3.2 to 4.3 mm), Part No. 1394465-5 ■ 5.0 mm grommet inner diameter (for insulation diameter from 4.3 to 5.3 mm), Part No. 1394465-1 ■ 6.0 mm grommet inner diameter (for insulation diameter from 5.3 to 6.2 mm), Part No. 1394465-2 ■ 7.0 mm grommet inner diameter (for insulation diameter from 6.2 to 7.2 mm), Part No. 1394465-3 ■ 8.0 mm grommet inner diameter (for insulation diameter from 7.2 to 8.0 mm), Part No. 1394465-4 The grommet has to be matched with the outer diameter of the solar cable (see customer drawing, Part No. 1394461 and Part No. 1394462) and the pinch ring (Part No. 1418677-2) must be applied. 24 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 25 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Assembly and Installation Guidelines (continued) When assembling the connectors, the following sequence must be followed: 1 Stripping the Wire (please refer to application specification # 114-74013) Fig. 1 8,0 mm 2 Insert the stripped wire into the wire crimp barrel until it stops. While holding the wire in place, squeeze tool handles together until ratchet releases. Fig. 2 3 Place seal/pinch ring combination into the connector housing until it stops. Fig. 3 4 Place backshell onto the connector housing. Fig. 4 5 Push contact with cable into the connector housing until you hear the contact is locked into position Fig. 5 6 Tighten backshell nut to 1.5 Nm Fig. 6 All specifications subject to change. Consult Tyco Electronics for latest specifications. 25 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 26 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Assembly and Installation Guidelines (continued) 3.2 Connector Latching When mating the SOLARLOK connectors, ensure the following: ■ Connectors labeled with a plus or minus are keyed and can only be mated to similarly marked and keyed connectors. CAUTION: The “neutral” designated pin connectors incorporate no keying features and must only be used for Serial Interconnection of Photovoltaic Modules. The neutral product should not be used where maintaining polarity is critical. The polarity of the “neutral” connector must labeled with Part No. 1394725-1 or Part No. 1394725-2 nearby the connector. ■ The connector system is fully latched only when the latches are flush with the mating connector. ■ After the connector is fully latched, the optional latch locking clip may be snapped into place. Fig. 7 (Female Connector) 3.3 Disconnecting CAUTION: This connector must not be disconnected under load. Disconnect circuit from load before unplugging connectors. Cable assemblies should be labeled using Tyco Electronics Label, Part No. 1394470-1. Unmating of the connector CAUTION: Do not disconnect the connector under load! 1 2 Fig. 8 1 1 The locking mechanism is opened by depressing the latches. 2 Pull out the connectors. While depressing the latches, disconnect the connector by pulling the connector halves apart. 26 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 27 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Assembly and Installation Guidelines (continued) 3.4 DC/AC Converter Receptacle 1 Place a single wire seal onto the wire and strip wire (single wire seals are not available with every version). Fig. 9 2 Crimp the contact using the correct applicator for the wire gauge (# 114-74013) Fig. 10 3 Place O-ring onto the connector housing; push in wire to stop until contact locks into the housing Fig. 11 4 Push seal into the housing Fig. 12 5 Assembly of the cover cap (not available with every version) and mounting in front panel Fig. 13 ■ Required panel mount hole diameter: Diameter 12.5 mm. ■ The panel thickness must not be under 1.0 mm. ■ For environmental protection of the unmated connector, use of the covering cap is recommended. Cover: Part No. 1394739-1 All specifications subject to change. Consult Tyco Electronics for latest specifications. 27 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 28 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Assembly and Installation Guidelines (continued) 4. Application Examples Fig. 14: Serial (Wire Diagram) Fig. 15: Parallel (Wire Diagram) 5. Storage See Product Specification 108-18701 6. Tooling ■ The following tools are available for the contact crimping (please specify wire gauge required): ● Hand Tool, integral Locator and Die (Part No. 1-1105851-8), use ‘HVT’ position on locator ● Hand Tool, only (Part No. 539973-1) ■ An extraction tool (Part No. 1102855-3) is needed to disassemble the connector components. This tool is used to unlock the contact retention features, after which the contact can be removed and re-used if necessary. Technical Description Fig. 16 28 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 29 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Technical Data (Junction Box and One Pole Plug Connectors) Materials Socket and Pin Contacts: CuZn Housing: PPO, weatherproof against UV radiation and ozone Color Connector, Junction Box: Black Electrical Features Withstanding Voltage: 1000 V DC Current Rating: up to 25 A Contact Resistance: �5 m� Contact Resistance (typical): 1 m� Protection Class: II Mechanical Features Junction Boxes Dimensions: Depending on junction box type Temperature Range: –40 °C to +105 °C Wire Size Range: up to AWG 12 Protection Degree: IP 65, closed Connector Dimensions: Diameter 18 mm, (diameter 0.71 inch) Temperature Range: –40 °C to +105 °C Wire Size Range: AWG 14, AWG 12, AWG 10 stranded wire Protection Degree: IP 67, mated Contact Finish: silver plated, Mating Cycles: 50, silver plated Unmating Force: 30–40 Newton Additional Features: Coded housing ensures mating safety Contact voltage-proof Connector with crimp technology Standards IEC 61215 Edition 2, 61646, IEC 61730, Protection Class II, UL 1703 Subject to Change. All specifications subject to change. Consult Tyco Electronics for latest specifications. 29 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 30 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Numerical Index Part Number Page Part Number Page Part Number Page Part Number Page 539630-1 22 1394470-1 26 1740210-7 11 1987376-2 16, 17 539973-1 28 1394470-1 24 1740210-8 11 1987376-3 16, 17 956297-4 14 1394723-3 2 1740210-9 11 1987376-4 16, 17 956297-5 14 1394723-4 21-1740210-0 11 1987376-5 16, 17 956297-6 14 1394723-5 3 1740220-1 6 1-1987376-1 16, 17 1-956297-4 14 1394723-6 3 1740220-2 6 1-1987376-2 16, 17 1-956297-5 14 1394723-9 3 1740220-3 6 1-1987376-3 16, 17 1-956297-6 141-1394723-6 2 1740220-4 6 1-1987376-4 16, 17 956298-4 142-1394723-6 2 1740277-1 10 1-1987376-5 16, 17 956298-5 14 1394725-1 26 1740277-2 10 2-1987376-1 16, 17 956298-6 14 1394725-2 26 1740425-1 6 2-1987376-2 16, 17 1-956298-4 14 1394738-1 11 1740425-3 6 2-1987376-3 16, 17 1-956298-5 14 1394738-2 11 1740479-1 12 2-1987376-4 16, 17 1-956298-6 14 1394738-3 11,20,21 1740483-1 12 2-1987376-5 16, 17 956299-4 14 1394738-4 11,20,21 1740483-2 12 3-1987376-1 17 956299-5 14 1394739-1 11,27 1740493-1 12 3-1987376-2 17 956299-6 14 1418677-2 24 1740493-2 12 3-1987376-3 17 1-956299-4 14 1418867-1 7 1740657-7 5 3-1987376-4 17 1-956299-5 14 1418867-2 7 1740657-8 5 3-1987376-5 17 1-956299-6 14 1418867-5 7 1740657-9 5 4-1987376-1 17 1102855-3 22,23,28 1418867-6 71-1740657-0 5 4-1987376-2 17 1-1105851-8 281-1418867-2 7 1740658-1 5 4-1987376-3 17 1394461-1 91-1418867-3 7 1740658-3 5 4-1987376-4 17 1394461-2 9 1534226-1 9 1740658-4 5 4-1987376-5 17 1394461-3 9,16,17 1534611-1 10 1740658-5 5 1394461-4 9,16,17, 1534611-2 10 1740699-1 4 20 1534858-1 23 1740699-6 4 6-1394461-1 9 1579000-4 22 1740700-1 4 6-1394461-2 9,205-1579001-4 22 1740700-3 4 6-1394461-4 95-1579001-5 22 1740863-1 8 6-1394461-5 96-1579001-6 22 1740863-2 8 6-1394461-6 97-1579001-8 22 1740969-1 23 1394462-1 97-1579001-9 22 1740969-2 23 1394462-2 98-1579001-2 22 1740971-1 4 1394462-3 9,16,17, 4-1579002-2 22,23 1740971-2 4 20, 21 1579004-8 22 1740972-1 4 1394462-4 9,16,17,1-1579004-1 22 1740972-3 4 20, 21 1-1579004-2 22,23 1954381-1 19 5-1394462-5 9 1579007-2 23 1986164-2 14 5-1394462-6 9 1579007-3 23 1986164-3 14 1394465-1 24 1579007-5 23 1986165-2 14 1394465-2 24 1740210-1 11 1986165-3 14 1394465-3 24 1740210-2 11 1986166-2 14 1394465-4 24 1740210-3 11 1986166-3 14 1394465-5 24 1740210-4 11 1987376-1 16, 17 30 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 31 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Restriction on the Use of Hazardous Substances (RoHS) At Tyco Electronics, we’re ready to support your RoHS requirements. We’ve assessed more Restriction on the Use than 1.5 million end items/components for RoHS compliance, and issued new part numbers of Hazardous Substances where any change was required to eliminate the restricted materials. Part numbers in this catalog (RoHS) are identified as: RoHS Compliant Part numbers in this catalog are RoHS Compliant, unless marked otherwise. These products comply with European Union Directive 2002/95/EC as amended 1 January 2006 that restricts the use of lead, mercury, cadmium, hexavalent chromium, PBB, and PBDE in certain electrical and electronic products sold into the EU as of 1 July 2006. Note: For purposes of this Catalog, included within the definition of RoHS Compliant are products that are clearly “Out of Scope” of the RoHS Directive such as hand tools and other non-electrical accessories. Non-RoHS Compliant These part numbers are identified with a “t” symbol. These products do not comply with the material restrictions of the European Union Directive 2002/95/EC. 5 of 6 Compliant A “l” symbol identifies these part numbers. These products do not fully comply with the European Union Directive 2002/95/EC because they contain lead in solderable interfaces (they do not contain any of the other five restricted substances above allowable limits). However, these prod- ucts may be suitable for use in RoHS applications where there is an application-based exception for lead in solders, such as the server, storage, or networking infrastructure exemption. Note: Information regarding RoHS compliance is provided based on reasonable inquiry of our suppliers and represents our current actual knowledge based on the information provided by our suppliers. This information is subject to change. For latest compliance status, refer to our website referenced below. Getting the Information You Need Our comprehensive on-line RoHS Customer Support Center provides a forum to answer your questions and support your RoHS needs. A RoHS FAQ (Frequently Asked Questions) is available with links to more detailed information. You can also submit RoHS questions and receive a response within 24 hours during a normal work week. The Support Center also provides: ■ Cross-Reference from Non-compliant to Compliant Products ■ Ability to browse RoHS Compliant Products in our on-line catalog: RoHS http://ecommas.tycoelectronics.com/commerce/alt/RohsAltHome.do Customer ■ Downloadable Technical Data Customer Information Presentation Support ■ More detailed information regarding the definitions used above Center So whatever your questions when it comes to RoHS, we’ve got the answers at www.tycoelectronics.com/leadfree All specifications subject to change. Consult Tyco Electronics for latest specifications. 31 2-SOLARLOK Inhalt, GB.qxd 20.05.2008 13:23 Uhr Seite 32 SOLARLOK Interconnection System Catalog 889753-3 Revised 6-2008 Engineering Notes All specifications subject to change. Consult Tyco Electronics for latest specifications. 32 1-SOLARLOK Cover, GB.qxd 19.05.2008 19:47 Uhr Seite 3 Global Contacts Americas Argentina – Buenos Aires Canada – Toronto Mexico – Mexico City United States Phone: +54-11-4733-2200 Phone: +1-905-475-6222 Phone: +52-55-1106-0800 Harrisburg, PA Fax: +54-11-4733-2211 Fax: +1-905-474-5520 +01-800-733-8926 Phone: +1-717-564-0100 Product Information Center: Fax: +52-55-1106-0901 Fax: +1-717-986-7575 Brasil – São Paulo Phone: +1-905-470-4425 Product Information Center: Phone: +55-11-3611-1311 Fax: +1-905-474-5525 Phone: +1-800-522-6752 Fax: +55-11-3611-0397 For Latin/South American Fax: +1-717-986-7575 Colombia – Bogota Countries not shown Troy, MI Phone: +57-1-231-9398 Phone: +54-11-4733-2015 Phone: +1-248-273-3359 Fax: +57-1-660-0206 Fax: +54-11-4733-2083 Fax: +1-248-273-3322 Asia/Pacific Australia – Sydney Japan – Kawasaki, Kanagawa New Zealand – Auckland Singapore – Singapore Phone: +61-2-9554-2600 Phone: +81-44-844-8111 Phone: +64-9-634-4580 Phone: +65-6482-0311 Fax: +61-2-9502-2556 Fax: +81-44-812-3207 Fax: +64-9-634-4586 Fax: +65-6482-1012 Product Information Center: Product Information Center: Philippines – Makati City Taiwan – Taipei Phone: +61-2-9840-8200 Phone: +81-44-844-8013 Phone: +632-848-0171 Phone: +886-2-8768-2788 Fax: +61-2-9634-6188 Fax: +81-44-812-3200 Fax: +632-867-8661 Fax: +886-2-8768-2268 India – Bangalore Korea – Seoul People’s Republic of China Thailand – Bangkok Phone: +91-80-285-40800 Phone: +82-2-3415-4500 Hong Kong Phone: +66-2-955-0500 Fax: +91-80-285-40820 Fax: +82-2-3486-3810 Phone: +852-2735-1628 Fax: +66-2-955-0505 Indonesia – Jakarta Malaysia – Selangor Fax: +852-2735-0243 Vietnam – Ho Chi Minh City Phone: +65-6482-0311 Phone: +60-3-7805-3055 Shanghai Phone: +84-8-930-5546 Fax: +65-6482-1012 Fax: +60-3-7805-3066 Phone: +86-21-2407-1588 Fax: +84-8-930-3443 Fax: +86-21-2407-1599 Europe/Middle East/Africa Austria – Vienna France – Cergy-Pontoise Cedex Lithuania and Latvia South Africa – Port Elizabeth Phone: +43-1-905-60-0 Phone: +33-1-3420-8888 Lithuania – Vilnius Phone: +27-41-503-4500 Fax: +43-1-905-60-1333 Fax: +33-1-3420-8600 Phone: +370-5-213-1402 Fax: +27-41-581-0440 Product Information Center: Product Information Center: Fax: +370-5-213-1403 Spain – Barcelona Phone: +43-1-905-60-1249 Phone: +33-1-3420-8686 Product Information Center: Phone: +34-93-291-0330 Fax: +43-1-905-60-1251 Fax: +33-1-3420-8623 Phone: +370-5-211-3016 Fax: +34-93-201-7879 Fax: +370-5-213-1403 Belarus – Minsk France Export Divisions – Sweden – Upplands Väsby Phone: +375-17-237-47-94 Cergy-Pontoise Cedex Netherlands – ’s-Hertogenbosch Phone: +46-8-50-72-50-00 Fax: +375-17-237-47-94 Phone: +33-1-3420-8804 Phone: +31-73-6246-246 Fax: +46-8-50-72-50-01 Fax: +33-1-3420-8699 Fax: +31-73-6212-365 Belgium – Kessel-Lo Product Information Center: Switzerland – Steinach Phone: +32-16-352-300 Germany – Bensheim Phone: +31-73-6246-999 Phone: +41-71-447-0447 Fax: +32-16-352-352 Phone: +49-6251-133-0 Fax: +31-73-6246-998 Fax: +41-71-447-0444 Fax: +49-6251-133-1600 Bulgaria – Sofia Product Information Center: Norway – Nesbru Turkey – Istanbul Phone: +359-2-971-2152 Phone: +49-6251-133-1999 Phone: +47-66-77-88-50 Phone: +90-212-281-8181-83 Fax: +359-2-971-2153 Fax: +49-6251-133-1988 Fax: +47-66-77-88-55 +90-212-282-5130/5430 Czech Republic and Slovakia Fax: +90-212-281-8184 Greece – Athens Poland – Warsaw Czech Republic – Kurim Phone: +30-210-9370-396/397 Phone: +48-22-4576-700 Ukraine – Kiev Phone: +420-541-162-111 Fax: +30-210-9370-655 Fax: +48-22-4576-720 Phone: +380-44-206-2265 Fax: +420-541-162-223 Product Information Center: Fax: +380-44-206-2264 Product Information Center: Hungary – Budapest Phone: +48-22-4576-704 Product Information Center: Phone: +420-541-162-113 Phone: +36-1-289-1000 Fax: +48-22-4576-720 Phone: +380-44-206-2265 Fax: +420-541-162-132 Fax: +36-1-289-1010 Fax: +380-44-206-2264 Product Information Center: Romania – Bucharest Denmark – Glostrup Phone: +36-1-289-1016 Phone: +40-21-311-3479/3596 United Kingdom – Phone: +45-43-48-04-00 Fax: +36-1-289-1017 Fax: +40-21-312-0574 Stanmore, Middlesex Fax: +45-43-44-14-14 Phone: +44-8706-080208 Ireland – Dublin Russia – Moscow Egypt – Cairo Fax: +44-208-954-6234 Phone: +353-1-866-5612 Phone: +7-495-790-7902 Phone: +202-419-2334 Product Information Center: Fax: +353-1-866-5714 Fax: +7-495-721-1893 Fax: +202-417-7647 Freephone (UK only): Product Information Center: Israel – Petach-Tikva +0800-267-666 Phone: +7-495-790-7902-404 Estonia – Tartu Phone: +972-3-929-0999 Phone: +44-8706-080208 Fax: +7-495-790-7902-401 Phone: +372-5138-274 Fax: +972-3-919-1088 Fax: +44-208-420-8095 Fax: +372-7400-779 Russia – St. Petersburg Italy – Collegno (Torino) Phone: +7-812-718-8192 Finland – Helsinki Phone: +39-011-4012-111 Fax: +7-812-718-8193 Phone: +358-95-12-34-20 Fax: +39-011-4031-116 Fax: +358-95-12-34-250 Product Information Center: Slovenia – Ljubljana Phone: +39-011-4012-428 Phone: +386-1561-3270 Fax: +39-011-40-287-428 Fax: +386-1561-3240 www.tycoelectronics.com 1-SOLARLOK Cover, GB.qxd 19.05.2008 19:47 Uhr Seite 4 Tyco Electronics AMP GmbH Siemensstr. 13 67346 Speyer / Germany Phone: +49-(0)6232-30-2520 Fax: +49-(0)6232-30-2243 www.tycoelectronics.com AMP, SOLARLOK, SOLKLIP, TE Logo and Tyco Electronics are trademarks. © 2008 Tyco Electronics Ltd. 889753-3 Revised 6-2008 5M ST

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the 1534858-1?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

High Frequency Chip Inductors In Laboratory Kits 1-1624110-0

product

High Frequency Chip Inductors In Laboratory Kits 1-1624110-2

product

High Frequency Chip Inductors In Laboratory Kits 1-1624110-3

product

Cable Connector Kits M Series 1-213684-0

product

Kits Include A 110V Battery Charger 1213890-1

product

Modular Plug Tools And Pistol Grip Tool Kit 1-231666-4