114-92003
February 20th, 2015 Rev G
Fiber Optic Outside Plant Cables
Buffer Tube
250µm Colored Fiber
Central Strength Member
Buffer Tube
Ripcord
Water Blocking Strength Members
Water Blocking Strength
Members
Polyethylene Outer Jacket
Polyethylene Outer Jacket
Central Tube Dielectric Cable Multi-Tube Dielectric Cable
4-12 Fiber 4-216 Fiber
The number of tubes changes depending on fiber count.
250µm Colored Fiber
Buffer Tube
250µm Colored Fiber
Central Strength Member
Buffer Tube
Water Blocking Strength Water Blocking Strength
Members
Corrugated Steel Armor
Ripcord
Ripcord
Polyethylene Outer Jacket
Corrugated Steel Armor
Polyethylene Outer Jacket
Central Tube Armored Cable
Multi-Tube Armored Cable
4-12 Fiber
4-144 Fiber
The number of tubes changes depending on fiber count.
Additional layers of armor available
Description:
TE Connectivity outside plant cables are designed for campus-type environments or for long
runs between buildings in aerial lashed, duct or direct buried installations. The cables consist
of 250µm inked fibers encased in color coded water blocked buffer tubes (dry or gel). Central
tube designs (4 to 12 fibers) include a single tube surrounded by water blocking strength
members and a medium-density polyethylene outer jacket. Stranded tube designs (24 to 288
fibers) include multiple tubes stranded around a central strength member, then covered by
water blocking strength members and a medium-density polyethylene outer jacket. The cables
are available in all dielectric and corrugated steel tape armored versions. All cables have a
black outer jacket.
© 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved. TE Connectivity, and TE
1 of 7
connectivity (logo) are trademarks. Other logos, product and/or company names might be trademarks of their respective
owners. This specification is subject to change without notice.
114-92003
Standards Compliance:
TE Connectivity OSP cables are designed and tested to conform to the fiber and cable
performance requirements of TIA 568, ISO 11801, Telcordia GR-20-CORE, ICEA S87-640,
and REA/RUS PE-90 Standards.
Cable Print:
Cables will be marked every two feet with:
TE CONNECTIVITY OSP or OSPA XXXXX FEET
Dry Water Blocked Tube Dielectric Part Numbers:
Fiber Count Units x Fibers/Unit 62.5/125 OM1 50/125 OM2 OM3 OM4 OS2 BIF
12 1 x 12 (with 4 fillers) - - - - 6-1553734-3
24 2 x 12 (with 3 fillers) - - - - 6-2193199-3
36 3 x 12 (with 2 fillers) - - - - 6-2193229-3
48 4 x 12 (with 1 filler) - - - - 6-2193200-3
72 6 x 12 - - - - 6-2193230-3
96 8 x 12 - - - - 6-2193231-3
144 12 x 12 - - - - 6-2193276-3
288 24 x 12 - - - - 6-2193158-3
Dry Water Blocked Tube Armored Part Numbers:
Fiber Count Units x Fibers/Unit 62.5/125 OM1 50/125 OM2 OM3 OM4 OS2 BIF
288 24 x 12 - - - - 6-2193441-3
432 36 x 12 - - - - 6-2193442-3
Gel Filled Tube Dielectric Part Numbers:
Fiber Count Units x Fibers/Unit 62.5/125 OM1 50/125 OM2 OM3 OM4 OS2 BIF
4 1 x 4 6-1553386-1 6-1553386-2 6-1553386-4 6-1553386-5 6-1553386-3
6 1 x 6 6-1553387-1 6-1553387-2 6-1553387-4 6-1553387-5 6-1553387-3
8 1 x 8 6-1553388-1 6-1553388-2 6-1553388-4 6-1553388-5 6-1553388-3
12 1 x 12 6-1553389-1 6-1553389-2 6-1553389-4 6-1553389-5 6-1553389-3
24 2 x 12 (with 3 fillers) 6-1553390-1 6-1553390-2 6-1553390-4 6-1553390-5 6-1553390-3
36 3 x 12 (with 2 fillers) 6-1553391-1 6-1553391-2 6-1553391-4 6-1553391-5 6-1553391-3
48 4 x 12 (with 1 filler) 6-1553392-1 6-1553392-2 6-1553392-4 6-1553392-5 6-1553392-3
72 6 x 12 6-1553393-1 6-1553393-2 6-1553393-4 6-1553393-5 6-1553393-3
96 8 x 12 6-1553394-1 6-1553394-2 6-1553394-4 6-1553394-5 6-1553394-3
144 12 x 12 6-1553395-1 6-1553395-2 6-1553395-4 6-1553395-5 6-1553395-3
216 18 x 12 6-1553440-1 6-1553440-2 6-1553440-4 6-1553440-5 6-1553440-3
REV G 2 of 7
114-92003
Gel Filled Tube Armored Part Numbers:
Fiber Count Units x Fibers/Unit 62.5/125 OM1 50/125 OM2 OM3 OM4 OS2 BIF
4 1 x 4 6-1553396-1 6-1553396-2 6-1553396-4 6-1553396-5 6-1553396-3
6 1 x 6 6-1553397-1 6-1553397-2 6-1553397-4 6-1553397-5 6-1553397-3
8 1 x 8 6-1553398-1 6-1553398-2 6-1553398-4 6-1553398-5 6-1553398-3
12 1 x 12 6-1553399-1 6-1553399-2 6-1553399-4 6-1553399-5 6-1553399-3
24 2 x 12 (with 3 fillers) 6-1553400-1 6-1553400-2 6-1553400-4 6-1553400-5 6-1553400-3
36 3 x 12 (with 2 fillers) 6-1553401-1 6-1553401-2 6-1553401-4 6-1553401-5 6-1553401-3
48 4 x 12 (with 1 filler) 6-1553402-1 6-1553402-2 6-1553402-4 6-1553402-5 6-1553402-3
72 6 x 12 6-1553403-1 6-1553403-2 6-1553403-4 6-1553403-5 6-1553403-3
96 8 x 12 6-1553404-1 6-1553404-2 6-1553404-4 6-1553404-5 6-1553404-3
144 12 x 12 6-1553405-1 6-1553405-2 6-1553405-4 6-1553405-5 6-1553405-3
Gel Filled Tube Double Armored Double Jacketed Part Numbers:
Fiber Count Units x Fibers/Unit 62.5/125 OM1 50/125 OM2 OM3 OM4 OS2 BIF
24 2 x 12 (with 3 fillers) - - - - 6-2193458-3
96 8 x 12 - - - - 6-2193459-3
REV G 3 of 7
114-92003
Composite Outdoor Cables:
Total OSP Dry or
Number of Number of Number of Number of
Number (dielectric) or Gel Number of OM4
Single-mode 62.5/125 OM1 50/125 OM2 OM3 Part Number
of OSPA Buffer Fibers
Fibers Fibers Fibers Fibers
Fibers (armored) Tubes
12 OSP Gel 6 - - 6 - 2111077-1
12 OSPA Gel 6 6 - - - 2193275-8
18 OSPA Gel 6 - 12 - - 1499599-1
24 OSP Gel 12 - 12 - - 1553484-8
24 OSP Gel 12 - - 12 - 2111078-1
24 OSP Gel 12 - - - 12 1499948-1
24 OSP Gel 12 12 - - - 4-1664208-5
24 OSPA Gel 12 - - - 12 1499951-1
24 OSPA Gel 12 - - 12 - 2111084-1
36 OSP Gel 12 24 - - - 4-1664209-5
48 OSP Dry 12 - - 12 - 2193278-8
48 OSPA Gel 24 - 24 - - 1553296-1
48 OSP Gel 24 24 - - - 1553602-8
72 OSP Gel 24 48 - - - 4-1664210-5
96 OSP Gel 72 - - - 24 1777231-1
96 OSPA Gel 48 - 48 - - 1553503-8
96 OSPA Gel 48 - - 48 - 1553504-8
144 OSPA Gel 72 72 - - - 2193274-8
Note: Composite cables are constructed in order of core size from smallest to largest. (i.e. single-mode fibers taking the first positions,
followed by 50/125µm then 62.5/125µm).
REV G 4 of 7
114-92003
Dry Water Blocked Tube Mechanical Specifications:
Rated Tensile Load Minimum Bend Radius
Nominal
Fiber Count
Cable Cable O.D. Tube O.D. Weight
Long Long
(tubes x fibers per Install Install
Type mm (in) mm (in) kg/km
Term Term
tube) N (lbf) mm (in)
(lbs/1000ft)
N (lbf) mm (in)
24 10.1±0.5 2.5±0.3
64 (43) 2670 (600) 890 (200) 200 (8) 100 (4)
(1 x 12 with 4 fillers) (0.40±0.02) (0.10±0.01)
24 10.1±0.5 2.5±0.3
64 (43) 2670 (600) 890 (200) 200 (8) 100 (4)
(2 x 12 with 3 fillers) (0.40±0.02) (0.10±0.01)
36 10.1±0.5 2.5±0.3
64 (43) 2670 (600) 890 (200) 200 (8) 100 (4)
(3 x 12 with 2 fillers) (0.40±0.02) (0.10±0.01)
48 10.1±0.5 2.5±0.3
64 (43) 2670 (600) 890 (200) 200 (8) 100 (4)
(4 x 12 with 1 fillers) (0.40±0.02) (0.10±0.01)
72 10.9±0.5 2.5±0.3
Dielectric
75 (50) 2670 (600) 890 (200) 220 (8) 110 (4)
(6 x 12) (0.43±0.02) (0.10±0.01)
96 12.6±0.5 2.5±0.3
97 (65) 2670 (600) 890 (200) 250 (10) 130 (5)
(8 x 12) (0.5±0.02) (0.10±0.01)
144 15.9±0.5 2.5±0.3
156 (105) 2670 (600) 890 (200) 320 (13) 160 (6)
(12 x 12) (0.63±0.02) (0.10±0.01)
288 18.3±0.5 2.5±0.3
216 (145) 2670 (600) 890 (200) 370 (14) 180 (7)
(24 x 12) (0.72±0.02) (0.10±0.01)
288 20.7±0.5 2.5±0.3
310 (208) 2670 (600) 890 (200) 420 (16) 210 (8)
(24 x 12) (0.81±0.02) (0.10±0.01)
Armored
432 23.0±0.5 2.5±0.3
376 (253) 2670 (600) 890 (200) 460 (18) 230 (9)
(36 x 12) (0.90±0.02) (0.10±0.01)
REV G 5 of 7
114-92003
Gel Filled Tube Mechanical Specifications:
Rated Tensile Load Minimum Bend Radius
Nominal
Fiber Count
Cable Cable O.D. Tube O.D. Weight
Long Long
(tubes x fibers per Install Install
Type mm (in) mm (in) kg/km
Term Term
tube) N (lbf) mm (in)
(lbs/1000ft)
N (lbf) mm (in)
4 7.8±0.3 4.2±0.3
50 (34) 2670 (600) 890 (200) 156 (6.1) 78 (3.1)
(1 x 4) (0.31±0.01) (0.16±0.01)
6 7.8±0.3 4.2±0.3
50 (34) 2670 (600) 890 (200) 156 (6.1) 78 (3.1)
(1 x 6) (0.31±0.01) (0.16±0.01)
8 7.8±0.3 4.2±0.3
50 (34) 2670 (600) 890 (200) 156 (6.1) 78 (3.1)
(1 x 8) (0.31±0.01) (0.16±0.01)
12 7.8±0.3 4.2±0.3
50 (34) 2670 (600) 890 (200) 156 (6.1) 78 (3.1)
(1 x 12) (0.31±0.01) (0.16±0.01)
24 10.2±0.9 2.6±0.3
90 (60) 2670 (600) 890 (200) 210 (8.3) 105 (4.1)
(2 x 12 with 3 fillers) (0.40±0.03) (0.10±0.01)
36 10.2±0.9 2.6±0.3
90 (60) 2670 (600) 890 (200) 210 (8.3) 105 (4.1)
(3 x 12 with 2 fillers) (0.40±0.03) (0.10±0.01)
Dielectric
48 10.2±0.9 2.6±0.3
90 (60) 2670 (600) 890 (200) 210 (8.3) 105 (4.1)
(4 x 12 with 1 fillers) (0.40±0.03) (0.10±0.01)
72 10.9±1.1 2.6±0.3
105 (71) 2670 (600) 890 (200) 229 (9) 115 (4.5)
(6 x 12) (0.43±0.04) (0.10±0.01)
96 12.6±1.2 2.6±0.3
125 (84) 2670 (600) 890 (200) 266 (10.5) 133 (5.2)
(8 x 12) (0.50±0.1) (0.10±0.01)
144 16.2±1.3 2.6±0.3
220 (148) 2670 (600) 890 (200) 340 (13.4) 170 (6.7)
(12 x 12) (0.64±0.05) (0.10±0.01)
216 16.4±1.5 2.6±0.3
223 (150) 2670 (600) 890 (200) 348 (13.7) 174 (6.9)
(18 x 12) (0.65±0.06) (0.10±0.01)
4 11.0±1.7 3.6±0.7
140 (94) 2670 (600) 890 (200) 244 (9.6) 122 (4.8)
(1 x 4) (0.43±0.06) (0.14±0.03)
6 11.0±1.7 3.6±0.7
140 (94) 2670 (600) 890 (200) 244 (9.6) 122 (4.8)
(1 x 6) (0.43±0.06) (0.14±0.03)
8 11.0±1.7 3.6±0.7
140 (94) 2670 (600) 890 (200) 244 (9.6) 122 (4.8)
(1 x 8) (0.43±0.06) (0.14±0.03)
12 11.0±1.7 3.6±0.7
140 (94) 2670 (600) 890 (200) 244 (9.6) 122 (4.8)
(1 x 12) (0.43±0.06) (0.14±0.03)
24 12.6±1.6 2.6±0.3
160 (108) 2670 (600) 890 (200) 272 (10.7) 136 (5.4)
(2 x 12 with 3 fillers) (0.49±0.06) (0.10±0.01)
Armored
36 12.6±1.6 2.6±0.3
218 (146) 2670 (600) 890 (200) 272 (10.7) 136 (5.4)
(3 x 12 with 2 fillers) (0.49±0.06) (0.10±0.01)
48 12.6±1.6 2.6±0.3
223 (150) 2670 (600) 890 (200) 272 (10.7) 136 (5.4)
(4 x 12 with 1 fillers) (0.49±0.06) (0.10±0.01)
72 13.4±1.6 2.6±0.3
181 (122) 2670 (600) 890 (200) 288 (11.3) 144 (5.7)
(6 x 12) (0.53±0.06) (0.10±0.01)
96 15.3±1.5 2.6±0.3
215 (144) 2670 (600) 890 (200) 326 (12.8) 163 (6.4)
(8 x 12) (0.60±0.06) (0.10±0.01)
144 18.8±1.7 2.6±0.3
280 (188) 2670 (600) 890 (200) 400 (15.7) 200 (7.9)
(12 x 12) (0.74±0.07) (0.10±0.01)
Double 24 16.3 2.5±0.3
277 (186) 2670 (600) 800 (180) 330 (13) 160 (6)
Jacket (2 x 12 with 3 fillers) (0.64) (0.09±0.01)
Double
96 19.1 2.5±0.3
344 (231) 2670 (600) 800 (180) 380 (15) 190 (8)
Armor (8 x 12) (0.75) (0.09±0.01)
REV G 6 of 7
114-92003
Optical Fiber Types:
Bend Insensitive Bend Insensitive Bend Insensitive Bend Insensitive
62.5/125 µm OM1
50/125 µm OM2 OM3 OM4 Single-mode OS2
(850nm/1300nm)
(850nm/1300nm) (850nm/1300nm) (850nm/1300nm) (1310nm/1550nm)
Maximum Cable
3.5/1.2 dB/km 3.5/1.5 dB/km 3.0/1.0 dB/km 3.0/1.0 dB/km 0.4/0.3dB/km
Attenuation
OFL Bandwidth Not Applicable
200/500 MHzkm 500/500 MHzkm 1500/500 MHzkm 3500/500 MHzkm
850nm Effective
Not Applicable Not Applicable 2000 MHzkm 4700 MHzkm Not Applicable
Modal Bandwidth
10 Gigabit
Ethernet at 850nm 33m 82m 300m 550m Not Applicable
Maximum Distance
TIA-492AAAA TIA-492AAAB TIA-492AAAC TIA-492AAAD
Fiber Specification IEC 60793-2-10 IEC 60793-2-10 IEC 60793-2-10 IEC 60793-2-10 ITU-T G.657.A1
A1b A1a.1 A1a.2 A1a.3
Temperature Ratings:
Operation Installation Storage/Shipping
-40°C to +70°C -30°C to +60°C -40°C to +70°C
(-40°F to +158°F) (-22°F to +140°F) (-40°F to +158°F)
REV G 7 of 7
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods