TE CONNECTIVITY 2-1609109-7
Specifications
Manufacturer
TE Connectivity
Manufacturers Part #
2-1609109-7
Lead Time
On Order with Factory
Industry Aliases
2-1609109-7
Sub-Category
Power Entry Modules
Brand
Corcom
Factory Pack Quantity
8
Datasheet

DDEController?Action=srchrtrv&DocNm=1654001_CORCOM_PRODUCT_GUIDE_P_SERIES&DocType=CS&DocLang=English&s_cid=1046.pdf
843 KiB
Extracted Text
Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Versatile Power Entry Module with Small Footprint P Series UL Recognized CSA Certified VDE Approved PE filtered PS non-filtered PS filtered P Series L models feature a high performance medical filter The P series CHAMELEON power entry module offers designed to help bring most digital equipment the most popular features in a small footprint design (including switching power supplies) into compliance As the first 10A module to provide all five power with EN55022, Level B (as well as FCC part 15J, Class entry functions in one compact design, the B) conducted emissions limits. They are available chameleon module readily adapts to its environment with current ratings of 6 and 10A. These high and the needs of international markets. performance versions are only available with • Snap-in or flange mounting mounting ears, single voltage selection, in a complete RFI shield with options for switch, fuses and current • Standard IEC 60321-1 C14 power inlet ratings. Mounting extenders are not compatible with • Both North American and metric fusing the L or Z models. capabilities Z models provide a high performance three element • Two voltage selection options (for 4-voltage differential mode circuit filter, with extended EMI selection, see the M, L or LA Series) attenuation similar to the M Series Z models, to help • Optional DPST on/off switch bring most digital equipment (including switching • Filter options for general purpose, medical and power supplies) into compliance with EN55022, Level high-performance EMI filtering B (as well as FCC Part 15J, Class B) conducted emis- sions limits. They are available with current ratings of The CHAMELEON module’s compact design and 6 and 10A. These high performance versions are only modular construction allows selection of the required available with mounting ears, single voltage selection, power entry feature — without altering the panel in a complete RFI shield with options for switch, fuses cutout. And the CHAMELEON module, with its and current ratings. Mounting extenders are not optional adapters, will fit several common panel compatible with the L or Z models. For minimum cutouts. depth behind the panel, see the M Series B models are non-filtered and incorporate an inter- Filter Types connection block. The block connects the voltage selection terminals of an unfiltered CHAMELEON The CHAMELEON module has four filter and one module with an IEC connector and an optional switch non-filtered option: to reduce external wiring. Compatible with the A or B RFI shield options. S models provide an extended performance two element circuit EMI filter, with attenuation similar to the EEB Series power inlet filter. It offers protection for general purpose applications with stray Line to Ground and Line to Line noise that must be attenu- ated at the power inlet. These filters have limited leakage current and are available in current ratings of 3, 6 and 10A. H models provide susceptibility protection with minimal leakage current, and are suitable for patient care and non-patient care medical equipment. 192 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. Power Inlet Filters & Power Entry Modules Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Versatile Power Entry Module with Small Footprint (continued) P Series Ordering Information Part numbers are constructed by selecting the alphanumeric character which represents the desired feature. Note: For any option where shown as “0” use the digit ZERO (0) not the letter (O). Mounting Extender Switch Voltage Fuse Filter Filter Shield Style Options! Options* Select" Options Type Current Options! P S J 0 XS S 60 Mounting Style Switch Option Fuse Options Filter Current E = Mounting ears 0 = Blank D = Dual fuse 0 = No filter (Horizontal axis) S = Double pole S = Single fuse 3 = 3A S = Snap-in single throw 6 = 6A M = Mounting ears (DPST) X = 10A (Vertical axis) 3 Extender Input Voltage Select Filter Type Shield Options Option 0 = Single voltage 0 = No filter 0 = No shield 0 = None S = Dual voltage" B = Interconnection A = Filter shield C = FN260 select (SMPS) block# B = Complete J = J Series X = Dual voltage" H = Medical Filter Shield L = L Series! select (series/parallel) L = High Performance C = Complete can 4 Medical (for L & Z models) S = General purpose 4 Z = High Performance Notes: Extender for J-Series or others 1 L Series extender cannot be added to units Fuse holder with a shield. No style of extender can be added to units with B or C shields. 2 Dual voltage options are not available with L or Z Filter Types 3 When using the interconnection block, the last 3 digits of the part number are BX (0, A, or B) 4 High performance versions (L or Z filter types) Optional switch are available with any switch or fuse option but only in 6 or 10A with horizontal (PE) or vertical (PM) mounting ears, single voltage (0), complete shield (C) and no extenders * For alternative switch orientation options, please contact technical support or your Corcom product sales representative Optional filter The part number PS0SXSS6B would represent: P Series (P) with a snap-in mount (S) with no extender (0) a switch (S) dual voltage select (X) single fusing (S) general purpose filter (S) for 6A (6) with a B shield (B) 193 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Versatile Power Entry Module with Small Footprint (continued) P Series Voltage Selection Shield Options P series power entry modules include the voltage The P series offers several RF shield options. The selector integral with the fuse holder. Three voltage metal shield, optional on S, H and B filtered models, selection options are each supported by one of three provides shielding from radiated emissions and different fuse holders. The fifth digit of the part provides an RF ground for the filter to the panel. This number specifies which of the three fuse holders is shield is available in two versions; a shield of the filter included to provide the desired voltage selection. components (designated by an A as the final digit) The single voltage fuse holder (option “0”) has no and a complete shield (designated by B as the final voltage indication markings. The dual voltage options digit). select 115V or 230V by removing the fuse holder, flip- The A shield covers the filter portion of the module ping it over, and reinstalling it. Voltage selection is and increases performance of the filter by protecting indicated through a window in the P Series door. The the components from RFI coupling. This shield “SMPS” fuse holder (option “S”) jumpers two inde- allows the use of the C or J extender. pendent P Series terminals to indicate 230V operation to a switching mode power supply. The The B shield covers the entire power entry module “PRSR” parallel/serial fuse holder (option “X”) with metal, protecting the filter from RFI coupling, connects the windings of the equipment’s dual and covering the mounting cut-out to block RFI primary transformer (not included) to step down the entering or leaving the equipment. The B shield voltage or double up the current. The markings on cannot be used with any extender. the voltage selection fuse holders also remind the A complete metal enclosure is integral to both the user to install the appropriate fuse for the current at high performance L and Z models, and must be spec- the selected voltage. ified by a C in the part number’s final digit. This option is only available with the L or Z models. Input Voltage Selection Schemes S - “SPMS” Jumper Type 115V 230V Power on/off Power Hot G A input Note 1 Note 1 B Ground Sel. C Jumpers Note 1 Note 1 Neutral H D SMPS Provision for single fusing X - “PRSR” Parallel / Serial Type for Dual Primary Transformer 115V 230V Power on/off “A” Shield G Hot A 115V Note 1 Note 2 B “B” Shield Ground C Note 1 Note 2 115V Neutral H D Transformer primary Provision for single fusing 194 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. Power Inlet Filters & Power Entry Modules Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Versatile Power Entry Module with Small Footprint (continued) P Series Fuseholder Accessories Another feature of the P series power entry module is GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord the versatile fusing arrangement. The fuse holder can hold two 1/4” x 1-1/4” (3AG) or 5 x 20mm (metric) fuses. Single fusing is supported with a conversion clip that shorts one of the two fuse positions, and is designated by an S in the sixth part number digit. A module designated for a single fuse may be reconfig- ured by the manufacturer or the user to accept two fuses by simply removing the shorting clip. For appli- PA100: Power interconnect assembly cations intended for dual fusing, specify a D in the sixth part number digit. For voltage select models. Designed for use with either filtered or non-filtered units, 6” wire leads Conversion Clip for Single Fuse Applications 3 PA101: Plug only PA102: Pins only for use with PA101 PA105: Same as PA100 but with two wires for units with no voltage selection Interconnection Block PA400: J Extender Installation of the unfiltered versions of the P series Extends P Series height to fit J panel cutout requires wiring of the IEC socket terminals to the optional switch and the switch to the fuse holder. PA410: L Extender Labor can be eliminated by ordering the module Extends P Series width to fit L panel cutout with an interconnection block. This feature, desig- PA420: C Extender nated by “BX” in the seventh and eighth digits, pre wires the module so that only connection to the Extends P Series height to fit C panel cutout equipment must be done during installation. The interconnection block includes a plastic case to prevent access to the internal connections. PA400 The dimensions of this alternative are the same as the Extender for filtered versions. J Series Extender J-Series or others Fuse holder C & L Extenders can not be used with B Shields. L Extender can not be used with shields Optional switch 195 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. Optional filter Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Versatile Power Entry Module with Small Footprint (continued) P Series Specifications Electrical Schematics Maximum leakage current each Line to Ground: H Model H & L Models S & Z Models LINE LOAD @ 120 VAC 60 Hz: 2 A .25 mA @ 250 VAC 50 Hz: 5 A .50 mA Hipot rating (one minute): Line to Ground: 2250 VDC Line to Line: 1450 VDC Rated Voltage(max.): 250VAC S Model LINE LOAD Operating Voltages: Selectable or Fixed 115/230 VAC Operating Frequency: 50/60 Hz Rated Current: Non-Filtered – 10A Filtered – 3, 6 or 10A L Model LINE LOAD Fuseholder: Accepts one or two fuses .25 x 1.25”(not included) or 5 x 20mm (not included) Switch: DPST 10,000 operations at 51A max. inrush Z Model LINE LOAD Case Styles Front View PM PE PS High Performance Version Only 2.88 2.39 2.29 2.496 58.16 63.4 73.15 60.71 1.58 1.22 40.13 30.98 1.22 1.95 49.53 30.98 196 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. Power Inlet Filters & Power Entry Modules Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Versatile Power Entry Module with Small Footprint (continued) P Series Case Styles (continued) Extender Options C Extender - FN260 J Extender - J Series 2.51 2.72 63.75 69.08 Bottom edge Bottom edge Standard Models - Side and Rear View Non-Filtered Filtered 3 2.29 58.16 2.13 .225 1.93 54.10 5.715 49.02 High Performance Models - Side and Rear View PM PE 2.39 2.17 60.71 55.12 1.12 3.93 28.45 1.23 99.82 31.24 4.42 112.27 197 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Versatile Power Entry Module with Small Footprint (continued) P Series Case Styles (continued) Shield Options “A” Shield “B” Shield 2.19 2.19 55.63 55.63 Note: Shields can only be used with filtered models. B shield may not be used with J or C extender Recommended Panel Cutout Cutout PM PE “A” 2.496 “B” 63.40 .06 1.575 R 1.524 40.00 .135 Mounting Hole Diameter 3.43 Note: For snap-in applications, the “A” sides must have a .020 [.508] radius on the installation side. Dimensions are for front mount applications. Rear mount dimensions should be determined based on customer’s application parameters. Snap-in models allow for front mounting only. Not recommended for use in plastic panels. Dimension “A” Dimension “B” +.008 - .000 +.008 - .000 Style No Shield Shielded High Performance Standard High Performance PM 1.06 [26.92] 1.12 [28.45] 1.12 [28.45] 2.13 [54.10] 2.201 [55.91] PE 1.12 [28.45] 1.12 [28.45] 1.15 [29.21] 2.201 [55.91]* 2.201 [55.91] PS 1.06 [26.92] 1.12 [28.45] - 2.201 [55.91]* - PSC 1.06 [26.92] 1.12 [28.45] - 2.52 [64.01] - PSJ 1.06 [26.92] 1.12 [28.45] - 2.60 [66.04] - PSL 1.12 [28.45] - - 2.201 [55.91]* - *For panel thickness of 0.031 - 0.079 [0.787 - 2.01] only. Use 2.213 [56.21] for panel thickness of 0.083 - 0.114 [2.0 - 2.90] 198 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. Power Inlet Filters & Power Entry Modules Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Versatile Power Entry Module with Small Footprint (continued) P Series Performance Data Common Mode / Asymmetrical (L-G) Typical Insertion Loss Differential Mode / Symmetrical (L-L) Measured in closed 50 Ohm system S Models 3A 6A 10A db db db 100 100 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 Frequency in MHz Frequency in MHz Frequency in MHz H Models 3 3A 6A 10A db db db 100 100 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 10 0 0 0 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 Frequency in MHz Frequency in MHz Frequency in MHz L Models 6A 10A db db 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0.01 0.1 1 10 30 0.01 0.1 1 10 30 Frequency in MHz Frequency in MHz Z Models 6A 10A db db 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 0.01 0.1 1 10 30 0.01 0.1 1 10 30 Frequency in MHz Frequency in MHz 199 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Versatile Power Entry Module with Small Footprint (continued) P Series Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 200 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change.
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the 2-1609109-7?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods