Electronics Finder chervon right Manufacturers chervon right T chervon right TE CONNECTIVITY chervon right 3EXM4S
About product Specifications Datasheet FAQ

TE CONNECTIVITY 3EXM4S

Image of TE CONNECTIVITY 3EXM4S

Description

Power Entry Module EMI/RFI Filtered M 3 POS 240VAC 3A Switch/Fuse ST 1 Port
3EXM4S

Part Number

3EXM4S

Price

Request Quote

Manufacturer

TE CONNECTIVITY

Lead Time

Request Quote

Category

Connectors »  Power Entry Module

Specifications

Manufacturer

TE Connectivity

Manufacturers Part #

3EXM4S

Industry Aliases

3EXM4S, 6609131-9

Sub-Category

Power Entry Modules

Brand

Corcom

Factory Pack Quantity

4

Datasheet

pdf file

DDEController?Action=srchrtrv&DocNm=1654001_CORCOM_PRODUCT_GUIDE_M_SERIES&DocType=Catalog+Section&DocLang=English&PartCntxt=6609131-7.pdf

842 KiB

Extracted Text

Power Inlet Filters & Power Entry Modules Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Slim Power Entry Module Family with Multiple Options M Series UL Recognized CSA Certified VDE Approved XM / ZM VM Ordering Information M Series • Family of slim power entry modules that consume 5 E F M 4 S C minimal depth behind panel Mounting Type • Four compact modules each provide a different C– Snap-In option combination Omit for flange mount • Available non-filtered or with one of four filter 3 circuits designed to meet a wide variety of Switch Option applications S – DPST on/off switch • Optional voltage selector configured for either Omit for none 2 or 4 voltage selection • Optional DPST on/off switch Voltage Selection Positions • Included fuseholder accepts either single 3AG fuse 1 or 4 or dual metric fuses M Series • Snap-in or flange mounting styles Filter Type Filter Types F – General purpose H – Medical H Models provide a basic performance dual X – High performance element circuit EMI filter with minimal leakage Z – Premium performance current, suitable for medical applications, with attenuation similar to the EAH Series power inIet V – Non-filtered filter. Leakage current designation F Models provide a basic performance dual E – Low leakage (<0.5 mA) element circuit EMI filter, with attenuation similar (Filtered models only) to the EEA Series Power Inlet Filter. X Models provide a high performance three Current Rating @120 VAC element differential circuit filter, with extended 3, 5 or 6A EMI attenuation similar to the X Series chassis filter, suitable for bringing most digital equipment (including switching power supplies) into compli- ance with FCC Part 15J, Class B conducted emissions limits. Z Models provide a premium performance three element differential circuit filter, with enhanced EMI low frequency attenuation similar to the P Series Z models, suitable for bringing most digital equipment (including switching power supplies) into compliance with EN55022 Level B as well as FCC Part 15J. For minimum panel footprint, see the P series on page 192. 183 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. 2 4 Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Slim Power Entry Module Family with Multiple Options (continued) M Series Specifications Accessories Maximum leakage current each Line to Ground: GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord HM FM XM/ZM @ 120 VAC 60 Hz: 2 A .25 mA .30 mA @250 VAC 50 Hz: 5 A .50 mA .50 mA Hipot rating (one minute): Line to Ground: 2250 VDC Line to Line: 1450 VDC Line to Load (switch off) non-filtered: 2500 VAC Rated Voltage (max.): 250VAC MA100: Power interconnect assembly Operating Frequency: 50/60 Hz For voltage select models. 8.5” wire leads Rated Current @ 120 VAC: 3 to 6A Rated Current @ 250 VAC: 3A models: 2A 5A models: 4A 6A Switched models: 5A 6A non-switched models: 6A MA101 : Plug only Required Fuse(s): Reversible fuseholder accepts one .25 x 1.25” (not included) MA102: Strip of 100 pins for use with MA101 or two 5 x 20mm (not included) MA104: Individual pins for use with MA101 Switch: DPST 100,000 operations at 70A max. inrush MA302: Two Voltage Selection Card Marked 120V/240V. One card comes standard with every 2 voltage M series module MA304: Four Voltage Selection Card Marked 100V/120V/230V/240V. One card comes standard with every 4 voltage M series module Available Part Numbers Non-Filtered Models Voltage Flange Mount Snap-In Selections 1 6VM1 6VM1S 6VM1C 6VM1SC 2 6VM2 6VM2S 4 6VM4 6VM4S 6VM4C 6VM4SC 0 0 1 General Purpose Filters 1 5EFM1 5EFM1S 5EFM1C 5EFM1SC MA400: Medical safety bracket assembly 4 5EFM4 5EFM4S 5EFM4C 5EFM4SC Prevents inadvertent removal of fuse(s) Medical Filters 1 5EHM1 5EHM1S 4 5EHM4 5EHM4S High Performance - FCC-B 1 3EXM1S MA401: Bracket only 4 3EXM4 3EXM4S MA402: Standoff only Premium Performance - EN55022-B 1 3EZM1S 4 3EZM4 3EZM4S 184 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. 0 1 2 0 2 3 Power Inlet Filters & Power Entry Modules 1 2 3 1 2 2 4 Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Slim Power Entry Module Family with Multiple Options (continued) M Series Accessories Fuse Installation Instructions (continued) MA601 - 604: Insulating Boot Plastic shroud for back of M series to prevent inadvertent access to connections 1. Remove power cord 2. Insert a pocket screwdriver at point “X” as shown A MA601: Fits M4S versions USE ONLY WITH MA602: Fits M1S versions 250V FUSES DISCONNECT POWER BEFORE REPLACING FUSES MA603: Fits M4 versions “X” MA604: First M1 versions A Section A-A 3 3. Gently lift the entire door UP approximately 1/4" (minimum) Once lifted, the door will pivot on it’s hinges to expose Voltage Selection the fuse holder 1. Open cover, using small blade screwdriver or Lift Up similar tool (see illustration on right) 2. Set aside cover/fuse block assembly 3. Pull voltage selector card straight out of housing, using indicator pin 4. When the fuse holder is installed in the single fuse position, 4. Orient selector card so that desired voltage is apply the screwdriver as shown and gently lift up Use screwdriver as shown, do not use fingers readable at the bottom NOT here 5. Orient indicator pin to point up when desired voltage is readable at bottom (note that when indi- cator pin is fixed, successive voltages are selected by rotating the card 90° clockwise) Insert Here 6. Insert voltage selector card into housing, printed When the fuse holder is installed in the dual fuse position, side of card facing forward toward IEC connector it will normally release as soon as the door is opened and edge containing the desired voltage first 7. Replace cover, and verify that indicator pin shows 5. Install one (1) AG fuse or two (2) metric fuses (see below) the desired voltage 6. Replace fuse holder into housing 7. Swing and push to snap door back in place Fuse Options 1 0 0 1 2 0 100V 120V 0 0 North American Metric single fuse installation dual fuse installation 2 3 0 2 4 0 Install fuses on one side only, do not install both AG and metric fuses at the same time 230V 240V 185 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. 0 0 0 2 4 1 2 0 0 0 0 0 0 1 0 2 3 0 1 2 3 2 4 Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Slim Power Entry Module Family with Multiple Options (continued) M Series Electrical Schematics Non-Filtered Models Filtered Models VM1 FM1 & HM1 Power On/Off Power On/Off Note 3 Neutral Note 2 HB K Neutral K Note 1 Note 2 Note 3 120V Phase J F L L G Hot Customer G Transformer Primaries VM2 FM4 & HM4 Power On/Off 120V 240V 120V 230V A Note 3 A 100V 240V 120V 20V HB B Power On/Off A A Neutral K 120V Note 2 Note 1 Note 2 H 100V Neutral K B C C Note 1 Note 4 D D C C 120V Note 3 D D E E 120V Hot J F F L F E E Note 1 Note 4 120V G Customer J F F L Phase Transformer Primaries Note 4 G Customer Transformer Primaries VM4 XM1 & ZM1 120V 230V Power On/Off Power On/Off 100V 240V 20V Note 2 Note 3 A A HB Neutral 100V Note 1 HB K Neutral Note 2 Note 1 C C D D JF E E 120V Phase J F L F Hot Note 1 G Customer G Transformer Primaries XM4 & ZM4   120V 230V 100V 240V   20V Power On/Off A A   Note 4 Note 2 100V K H B Neutral   Note 1 C  C D D  E E 120V Phase J F F L Note 4 G Customer Transformer Primaries            186 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. Power Inlet Filters & Power Entry Modules Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Slim Power Entry Module Family with Multiple Options (continued) M Series Case Styles - Non-filtered Models 6VM1 6VM2 & 6VM4 100V USE ONLY WITH USE ONLY WITH 120V 250V FUSES C 250V FUSES 230V C 240V DISCONNECT POWER DISCONNECT POWER BEFORE REPLACING FUSES BEFORE REPLACING FUSES E D E D B B A A                 6VM1C 6VM4C 100V USE ONLY WITH 120V 3 USE ONLY WITH 250V FUSES 230V 250V FUSES C C 240V DISCONNECT POWER DISCONNECT POWER BEFORE REPLACING FUSES BEFORE REPLACING FUSES D D E E A A           6VM1S 6VM2S & 6VM4S 100V USE ONLY WITH USE ONLY WITH 120V 250V FUSES 250V FUSES C 230V C 240V DISCONNECT POWER DISCONNECT POWER BEFORE REPLACING FUSES BEFORE REPLACING FUSES E D E D B B A A                 6VM1SC 6VM4SC 100V USE ONLY WITH USE ONLY WITH 120V 250V FUSES 250V FUSES 230V C C 240V DISCONNECT POWER DISCONNECT POWER BEFORE REPLACING FUSES BEFORE REPLACING FUSES B D E E A A           187 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Slim Power Entry Module Family with Multiple Options (continued) M Series Case Styles - Filtered Models 3EXM1S & 3EZM1S 3EXM4S & 3EZM4S Threaded G G Threaded Insert Insert 1.17* 1.13* 29.7 28.7 1.88* 1.88* 3.09 3.09 Max. Max. 47.8 47.8 78.49 78.49 100V USE ONLY WITH 120V USE ONLY WITH 250V FUSES 230V 250V FUSES 240V C C DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES D D E E B B *±.020 [.508] *±.020 [.508] A A                     3EXM4 & 3EZM4 5EHM1 & 5EFM1 G Threaded Insert USE ONLY WITH 250V FUSES C DISCONNECT POWER BEFORE REPLACING FUSES 1.13* 28.7 E D 1.88* 3.09 B Max. 47.8 78.49 A 100V USE ONLY WITH 120V 250V FUSES 230V C 240V DISCONNECT POWER BEFORE REPLACING FUSES D E B *±.020 [.508] A                   188 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. Power Inlet Filters & Power Entry Modules Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Slim Power Entry Module Family with Multiple Options (continued) M Series Case Styles - Filtered Models (continued) 5EFM1C 5EHM4 & 5EFM4 100V USE ONLY WITH USE ONLY WITH 120V C 250V FUSES 250V FUSES 230V C 240V DISCONNECT POWER DISCONNECT POWER BEFORE REPLACING FUSES BEFORE REPLACING FUSES E D D E A B A             3  5EHM1S & 5EFM1S 5EFM4C USE ONLY WITH 100V USE ONLY WITH 250V FUSES C 120V 250V FUSES 230V C DISCONNECT POWER 240V BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES E D D E B A A              5EFM1SC 5EHM4S & 5EFM4S 100V USE ONLY WITH USE ONLY WITH 120V C 250V FUSES 250V FUSES 230V C 240V DISCONNECT POWER DISCONNECT POWER BEFORE REPLACING FUSES BEFORE REPLACING FUSES E D D E B A A              189 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Slim Power Entry Module Family with Multiple Options (continued) M Series Case Styles - Filtered Models Case Dimensions (continued) 5EFM4SC A B CD E F G Part No.         100V USE ONLY WITH 120V 250V FUSES 230V       C 240V DISCONNECT POWER  6VM1 BEFORE REPLACING FUSES       D E        6VM1C A             6VM1S              6VM1SC      6VM2        6VM4                 6VM4C        6VM2S        6VM4S              6VM4SC             3EXM1S Recommended Panel Cutouts 3EZM1S        3EXM4        3EZM4        Insert on XM and ZM .170 Dia. 3EXM4S        models only 4.32 1.17* 3EZM4S 1.88*        4S Models 29.7 47.8       5EHM1 1.13*  1S & 4 models 28.7 5EFM1       0.13 R 3.30      .570   5EFM1C 14.5 1.145      .170 29.08 Dia. 5EHM1S       4.32  5EFM1S       .175      F   4.45 *± .020 [.508] 5EFM1SC      B       5EHM4    5EFM4                5EFM4C        5EHM4S        5EFM4S              5EFM4SC      190 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change. Power Inlet Filters & Power Entry Modules Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 Slim Power Entry Module Family with Multiple Options (continued) M Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 5EHM 5EFM 3EXM 3EZM db db db db 100 100 100 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 10 0 0 0 0 0.1 . 1 5 1 10 30 0.1 . 1 5 1 10 30 0.1 1 10 30 0.1 1 10 30 Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz 3 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system Differential Mode / Symmetrical (Line to Line) Common Mode / Asymmetrical (Line to Ground)                                                                                 191 Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specifications subject to change.

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the 3EXM4S?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Power Entry Module EMI/RFI Filtered M 3 POS 250VAC 10A/Contact Switch ST 1 Port 10CBE1

product

Power Entry Module EMI/RFI Filtered M 3 POS 250VAC 10A/Contact Switch ST 1 Port 10CBS1

product

Power Entry Module EMI/RFI Filtered M 3 POS 250VAC 10A/Contact Switch ST 1 Port 10CE1

product

Power Entry Module EMI/RFI Filtered M 3 POS 250VAC 10A Switch ST 1 Port 10CFE1

product

Power Entry Module EMI/RFI Filtered M 3 POS 250VAC 10A Switch ST 1 Port 10CFS1

product

Power Entry Module EMI/RFI Filtered M 3 POS 250VAC 10A Switch ST 1 Port 10CHE1