Electronics Finder chervon right Manufacturers chervon right T chervon right THOMAS & BETTS chervon right 1215TB
About product Specifications Datasheet FAQ

THOMAS & BETTS 1215TB

Image of THOMAS & BETTS 1215TB

Description

Fittings Strap 1.5in Steel
1215TB

Part Number

1215TB

Price

Request Quote

Manufacturer

THOMAS & BETTS

Lead Time

Request Quote

Category

Fasteners, Hardware and Fluid Transfer »  Fittings

Specifications

Manufacturer

Thomas & Betts

Manufacturers Part #

1215TB

Sub-Category

Fittings

Factory Pack Quantity

1

Datasheet

pdf file

rigid-and-intermediate-metal-conduit-fittings.pdf

9117 KiB

Extracted Text

® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Locknuts Cat. No. Dimensions (in.) Size (in.) Stl. or M.I. Alum. SST A B † 1/4 27/32 5/32 139* — — 3/8 15/16 5/32 140* — — 1/2 1-7/64 5/32 141** 141AL 141SST 3/4 1-3/8 3/16 142-TB** 142AL 142SST A (B) Thickness 1 1-11/16 13/64 143 143AL 143SST 1-1/4 2-5/32 13/64 144 144AL 144SST 1-1/2 2-1/2 13/64 145 145AL 145SST 2 3 7/32 146-TB 146AL 146SST 2-1/2 3-9/16 13/32 147 147AL — 3 4-3/16 13/32 148 148AL — Steel or malleable iron (steel thru 2 in.) 3-1/2 4-13/16 15/32 149 149AL — or Aluminum 624 4 5-5/16 15/32 150 150AL — Many of the T&B standard conduit and cable fittings are furnished with “case hardened locknuts”. This exclusive feature means the locknut tightens up against 4-1/2 5-15/16 17/32 151 151AL — the box without deforming; the locknut bites into the box providing a positive 5 6 -1/2 17/32 152 152AL — ground; the fitting can be tightened from outside the box 6 7-3/4 17/32 153 153AL — * Hex shape ** Case hardened locknuts Aluminum locknuts comply with federal standard of copper-free aluminum; less than 0.4% copper † Not UL or CSA certified Bonding Locknuts Dimensions (in.) Cat. No. Size (in.) Screw Size (in.) (B) Thickness A A B 1/2 1-3/8 0.125 106 3/4 1-5/8 0.140 107 1 1-15/16 0.170 108 8-32 x 7/16 1-1/4 2-5/32 0.170 109 Steel or malleable iron (steel thru 2 in.) 1-1/2 2-1/2 0.170 110-TB Use anywhere an ordinary locknut is installed to ensure positive bonding of 2 3 0.187 111 conduit to box and prevent loosening due to vibration. Also can be used for 2-1/2 3-13/32 0.375 112-TB Service Entrance applications in conformance with Code. T&B rigid conduit and EMT (thinwall) fittings comply with Federal Specification WF 408c. 3 4-13/16 0.375 113-TB 1/4-20 x 5/8 3-1/2 4-29/32 0.438 114 4 5-7/16 0.438 115-TB Steel finish: zinc plated Fittings Dimensions (in.) A Cat. No. Size (in.) A B C 141SL 1/2 1.140 1/8 1/4 142SL 3/4 1.420 5/32 9/32 143SL 1 1.770 11/64 9/32 144SL 1-1/4 2.281 11/64 5/16 B 145SL 1-1/2 2.598 11/64 9/32 C 2 3.175 3/16 19/64 146SL Steel finish: zinc plated Molded Santprene Seal / Colour: Blue Provides positive seal against water and oil. For use with rigid and intermediate metal conduits, or fittings to provide watertight or raintight seal at all enclosures. NPS threads.. w w w .tnb .c a B9 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Sealing Rings with Stainless Steel Retainer Dimensions (in.) Cat. No. Conduit Size (in.) A B±1/64 5302 1/2 1-11/64 3/4 A B 5303 3/4 1-1/2 15/16 5304 1 1-3/4 1-11/64 5305 1-1/4 2-9/64 1-1/2 5306 1-1/2 2-27/64 1-3/4 5307 2 2-59/64 2-15/64 Sealing Ring-Santoprene Thermoplastic Rubber 5308 2-1/2 3-7/16 2-43/64 These sealing rings provide a liquid tight, dust tight, seal of fitting at 5309 3 4-5/64 3-19/64 enclosures 5311 4 5-9/32 4-19/64 NEMA 3R, 4, 6 and 13 Bonding and Grounding Wedges Application Standard Material/Finish To effectively bond terminating fitting or 1/2 in. size conduit to a box or enclosure Steel/Electro-zinc Plated Features 3/4 in. thru 6 in. size Series 3650 • Sizes 3/4 in. thru 6 in. equipped with an Bronze/TiPlated additional bonding screw to install Range bonding jumper where required 1/2 in. thru 6 in. conduit • Can be added to an existing installation Conformity without disconnecting conductors UL 467 C.S.A. C22.2 No. 41 NFPA70-2008 (ANSI) Federal Specification A-A-50552 Series 3651 Especially suited for grounding old work, but equally Bonding and Grounding convenient for new, grounding wedges provide ground- Wedges ing without a jumper except in concentric knockouts. When a jumper is required, it fits under a set screw in the grounding wedge. Cat. No. Size (in.) 3650 1/2 Update existing installations to meet code require- 3651 3/4 ments for bonding (CEC Section 10-806) without 3652 1 disconnecting wiring. Use on new wiring also. 3653 1-1/4 1. Loosen bushing and position wedge 3654 1-1/2 2. Tighten bushing and bonding screw 3655 2 3656 2-1/2 3657 3 3658 3-1/2 3659 4 3661 5 3662 6 w w w .tnb .c a B10 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings ® Blackjack — Conduit Grounding Bushings Innovative design makes installation quicker, Innovative design improves performance Mounting Integral grounding Insulating nylon easier. ® screw with lug enhances surface is 150°C The Blackjack bushing provides superior ground ® nylon locking ground continuity. rated and covers The Blackjack Grounding Bushing never has to continuity patch has a Added ground top of bushing, be threaded onto a conduit. It is simply placed in cone point to wire range taking including lug ® The design of the Blackjack bushing has an position on either a threaded or non-threaded rigid lock bushing reduces inventory. corners securely Accepts c opper or integral, cast-on grounding lug for better ground or IMC conduit, with the grounding lug in perfect Angle of lug in place aluminum ground ® screw improves continuity. This means that the Blackjack bushing position to accept the grounding wire. Even in tight wires accessibility stands up to intense loads. installations, it’s as simple as one, two, three. when securing Compare the installation with conventional grounding wire Secure grip forms lasting bond bushings that must be threaded onto the conduit. ® In tight areas, you may have to remove the The Blackjack bushing’s cone grounding lug, keep up with the loose parts, and point mounting screw bites then reattach the lug. Then you still have to twist securely into both threaded and turn the bushing to get the lug in position to and non-threaded rigid ® ® accept the grounding wire. The Blackjack conduits. And the Blackjack bushing does away with these needless delays bushing’s nylon locking patch for good, making it the ideal grounding bushing is designed to prevent the and the only logical choice for small spaces, screw from loosening due to corners, and multiple conduit runs. And, because vibration. the grounding lug is an integral part of the bushing, Reduce inventory it is designed not to fall off or get lost. ® Because the Blackjack Grounding Bushing is designed for threaded and non-threaded conduits, and the ground lugs are designed to handle an extended range, the number of parts in inventory is reduced by up to two-thirds without losing any application coverage. Insulator surface Cast “threads” features a rounded opposite the design to reduce mounting screw drag and prevent tighten the fit abrasion during during installation wire pulling ® Blackjack — Conduit Grounding Bushings Lug Screw: Range • 14-4: Slotted Conduit: 1/2 in. thru 6 in. threaded or threadless rigid/IMC • 14-2/0: Slotted Wire Range: #14 AWG to 4/0 AWG CU/AL • 6-4/0: Internal Hex Drive Conformity Standard Material/Finish UL 514B & UL 467 Body: Malleable Iron or Aluminum Mounting Screw: (1/2 in.-2 in.) CSA C22.2 No. 18.3 & CSA C22.2 Stainless Steel, No. 41 (2-1/2 in.-6 in.) Brass Lug Screw: Stainless Steel Finish: Zinc Plated or Mechanical Galvanized w w w .tnb .c a B11 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings ® Blackjack – Conduit Grounding Bushings Cat. No. Dim. Conduit Size Wire Range Zinc Plated ØA ØB ØC ØD E (in.) Aluminum Malleable Iron Max. Max. Max. Max. Max. 1.251 0.569 1.181 2.134 14-2/0 BG050-14-20 BGA050-14-20 1/2 1.251 0.569 1.027 1.940 14-4 BG050-14-4 BGA050-14-4 1.533 0.772 1.221 2.414 14-2/0 BG075-14-20 BGA075-14-20 3/4 0.696 1.533 0.772 1.030 2.168 14-4 BG075-14-4 BGA075-14-4 1.783 0.993 1.181 2.581 14-2/0 BG100-14-20 BGA100-14-20 1 1.783 0.993 1.027 2.368 14-4 BG100-14-4 BGA100-14-4 1-1/4 2.220 1.319 1.181 2.987 0.759 14-2/0 BG125-14-20 BGA125-14-20 1-1/2 2.470 1.553 1.181 3.236 14-2/0 BG150-14-20 BGA150-14-20 0.696 2 2.830 2.010 1.181 3.766 14-2/0 BG200-14-20 BGA200-14-20 3.148 2.412 1.181 4.341 14-2/0 BG250-14-20 BGA250-14-20 2-1/2 3.148 2.412 1.524 4.526 6-4/0 BG250-6-40 BGA250-6-40 4.042 3.022 1.181 4.966 14-2/0 BG300-14-20 BGA300-14-20 3 4.042 3.022 1.524 5.139 6-4/0 BG300-6-40 BGA300-6-40 4.542 3.491 1.181 5.467 14-2/0 BG350-14-20 BGA350-14-20 3-1/2 4.542 3.491 1.524 5.639 6-4/0 BG350-6-40 BGA350-6-40 0.978 5.042 3.975 1.181 5.966 14-2/0 BG400-14-20 BGA400-14-20 4 5.042 3.975 1.524 6.139 6-4/0 BG400-6-40 BGA400-6-40 6.136 4.991 1.181 7.045 14-2/0 BG500-14-20 BGA500-14-20 5 6.136 4.991 1.524 7.207 6-4/0 BG500-6-40 BGA500-6-40 7.199 6.009 1.181 8.087 14-2/0 BG600-14-20 BGA600-14-20 6 7.199 6.009 1.524 8.409 6-4/0 BG600-6-40 BGA600-6-40 Suggested Specifications Insulated grounding and bonding bushing (Series BG050-BG600) Where code requires bonding and grounding of single or multiple metal conduits, or positive bonding and grounding of metal conduit to the box, enclosure or auxiliary gutter, the end of the conduit shall be equipped with an insulated metallic grounding and bonding bushing Series BG050-14-20 as manufactured by Thomas & Betts. Grounding and bonding bushings used shall be approved for the purpose and (i) Shall be of malleable iron/steel/aluminum construction adequately protected against corrosion. (ii) B ushing insulator shall be listed or certified for 150°C/302°F application with a flammability rating of 94V-O. Insulator must be positively locked in place. * Mechanical galvanization is available in the 3870 Series; add suffix MG to Cat. No. Nylon Insulator (150°C) Mounting Screw Lug Screw 14-4: Slotted 14-2/0: Slotted 6-4/0: Internal hex drive C ØA E D ØB For Threaded & Threadless Rigid & IMC Conduit Throat I.D. w w w .tnb .c a B12 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Application Standard Material / Finish Threaded Insulated • F or quick installation of bonding Body: Electro-zinc plated Grounding Bushing jumper to multiple metal conduits Lay-in lug: Aluminum/tin-plated (Rigid and IMC) Insulator: Thermoplastic • D esigned to bush conductors and 150°C/302°F prevent insulation damage Application with 94V-0 flammability Features • E ase of installation, lay in lug design • C ast malleable iron body designed to lock insulator in place within body, reducing common assembly problem resulting in dislodging of insulator • I nsulator rated for 150°C/302°F application Wire Conduit Bushing Throat Lug Swing Bushing Wire Range Clamping Screw Cat. No. Size (in.) Dia. (in.) Dia. (in.) Lenght (in.) Radius (in.) Height (in.) AWG CU/AL Lay-In* Insulator Lug 1.125 0.560 1.310 1.212 14-4 3870-TB 1/2 0.657 3861 1.125 0.560 1.675 1.402 8-2/0 Set-Screw 3871-TB 1.420 0.742 1.310 1.360 14-4 (one) 3/4 0.660 1.420 0.742 1.675 1.550 8-2/0 3862 1.770 0.944 1.310 1.535 14-4 3872 1 3882 1.770 0.944 1.675 1.725 8-2/0 0.735 Bushing 3873 2.190 1.242 1.310 1.745 14-4 1-1/4 Casting 2.190 1.242 1.675 1.935 8-2/0 3883 3874 2.468 1.449 1.310 1.884 14-4 1-1/2 3884 2.468 1.449 1.675 2.074 8-2/0 0.770 3.031 1.860 1.310 2.165 14-4 3875 2 3.031 1.860 1.675 2.355 8-2/0 3889 3876 3.516 2.222 1.310 2.408 14-4 3886 2-1/2 3.516 2.222 1.675 2.598 0.940 8-2/0 3.516 2.222 2.230 2.928 6-4/0 3993 3877 4.234 2.761 1.310 2.767 14-4 3887 3 4.234 2.761 1.675 2.957 8-2/0 4.234 2.761 2.230 3.287 6-4/0 3994 0.975 4.781 3.193 1.310 3.040 14-4 3878 3863 3-1/2 4.781 3.193 1.675 3.230 8-2/0 3995 4.781 3.193 2.230 3.560 6-4/0 5.328 3.623 1.310 3.314 14-4 3879 3864 4 5.328 3.623 1.675 3.504 0.980 8-2/0 3996 5.328 3.623 2.230 3.834 6-4/0 6.328 4.542 1.310 3.814 14-4 3880 5 6.328 4.542 1.675 4.000 0.985 8-2/0 3865 3998 6.328 4.542 2.230 4.334 6-4/0 3881 7.406 5.458 1.310 4.353 14-4 6 7.406 5.458 1.675 4.543 1.200 8-2/0 3866 3999 7.406 5.458 2.230 4.875 6-4/0 Temperature rating 150°C Meets Coast Guard Regulation CG293 *Contact your Regional Sales Office for copper lay in lug w w w .tnb .c a B13 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings A Insulated Throat Fittings Cat. No. Dimensions (in.) B Size (in.) Steel or M.I. Aluminum A B 1222 1222AL 1/2 1-1/32 29/64 1223 1223AL 3/4 1-9/32 31/64 1224 1224AL 1 1-19/32 19/32 Nylon insulated metallic bushings 1225 1225AL 1-1/4 1-15/16 21/32 Steel or malleable iron (Steel thru 1-1/2 in.) 1226 1226AL 1-1/2 2-3/16 23/32 The Canadian Electric Code 10-906 (2) calls for protetion of 2 2-11/16 7/8 1227 1227AL ungrounded conductors by means of smoothly rounded insulating 2-1/2 3-3/16 31/32 1228 1228AL surfaces at the entrance to raceways, pull boxes, junction boxes, etc. T&B insulated throat fittings, recognizable by the 3 3-27/32 15/16 1229 1229AL distinctive trademarked blue insulating liner in the throat, meet 3-1/2 4-7/16 1-1/16 1230 1230AL and surpass this Code requirement. In addition, T&B insulated 1231 1231AL 4 4-7/8 1-3/32 fittings also reduce wire pulling effort by as much as 50%. 1232† 1232AL† 4-1/2 5-7/16 1-15/64 Temperature rating 105°C. 586 586AL 5 5-31/32 1-9/32 587 587AL 6 7-3/16 1-11/32 † Not CSA Certified The aluminum series are not CSA certified Metallic Bushings Cat. No. Dimensions (in.) Size (in.) B Steel or M.I. Aluminum A B 122 122AL 1/2 1-1/32 13/32 123 123AL* 3/4 1-9/32 13/32 A 124 124AL 1 1-19/32 1/2 125-TB 125AL 1-1/4 1-15/16 9/16 Aluminum, steel or malleable iron 126 126AL 1-1/2 2-3/16 9/16 (steel thru 1-1/2 in.) Smoothly rounded shoulder covers end of conduit; broad flange covers 127 127AL 2 2-11/16 19/32 knockout hole. High ribs make tightening easy with fingers or with 128 128AL 2-1/2 3-3/16 13/16 wrench. 1/2 in.-1-1/2 in. sizes, formed in steel, have extra smooth 3 3-27/32 13/16 129 129AL shoulders. Locknut-type base gives improved bonding and resists 3-1/2 4-7/16 15/16 130-TB 130AL loosening under conditions of vibration. 4 4-7/8 1 131-TB 131AL 4-1/2 5-7/16 1-5/64 132-TB — 133-TB 133AL 5 6-1/16 1-1/16 134-TB 134AL 6 7-3/16 1-1/16 * Not UL Listed or CSA Certified Plastic Insulating Bushings A Dimensions (in.) Cat. No. Size (in.) A B 222-TB 1/2 1-1/16 3/8 B 3/4 1-9/32 13/32 223-TB 1 1-37/64 9/16 224 1-1/4 2-1/32 9/16 225-TB 1-1/2 2-15/64 9/16 226 227 2 2-25/32 5/8 All Plastic Insulating Bushings 228-TB 2-1/2 3-13/32 3/4 Impact-resistant plastic insulation. These bushings have ribs for 229-TB 3 4-3/32 3/4 gripping when installing. Perfect threads for easy thread on. UL Listed 230-TB 3-1/2 4-5/8 7/8 105°C. NPT threaded. 231 4 5-3/16 7/8 232 4-1/2 5-5/8 7/8 233 5 6-3/8 1 234 6 7-7/16 1 Flame retardant. UL Rated 94V-1 w w w .tnb .c a B14 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Insulating Bushing for Threadless Rigid Conduit and Intermediate Metal Conduit Application Standard Material • W hen assembled to the end of a threadless High impact thermoplastic listed for 105°C conduit, provides a well rounded insulating (221°F) application surface over which conductors may be Flammability Classification 94V-1 pulled or on which conductors may bear Standard Finish while in service As molded Features Range • D esigned to be popped onto, and bush, 1/2 in. through 4 in. conduit conduit end Conformity • F ast easy installation without screws • H igh impact thermoplastic construction UL 514B ANSI C80.4 NFPA 70-2008 (ANSI) TRIB50 Series 1. Cut conduit end squarely. Remove sharp edges and burrs on inside and outside diameters by reaming or filing. 2. Slip the pop-on bushing over the end of the conduit. 3. Using the flat surface of any standard utility tool such as an electricians pliers (or a hammer with a block of wood, for the larger sizes), strike the bushing on its top surface using a Series of light blows until the end of the conduit rests against the bushing throat and conduit stop. Insulated Metallic Bushing Dimensions (in.) Cat. No. Size (in.) A B C 1/2 19/32 1-9/32 1-1/16 TRIB-50 3/4 25/32 1-25/64 1-1/4 TRIB-75 1 1 1-1/2 1-9/16 TRIB-100 1-1/4 1-5/16 1-5/8 1-59/64 TRIB-125 1-1/2 1-17/32 1-21/32 2-11/64 TRIB-150 2 1-31/32 1-13/16 2-11/16 TRIB-200 A 2-1/2 2-23/64 2 3-1/4 TRIB-250 3 2-59/64 2-7/32 3-29/32 TRIB-300 3-1/2 3-3/8 2-5/16 4-29/64 TRIB-350 B 4 3-27/32 2-13/32 5 TRIB-400 I.M.C. sizes 1/2 in. thru 4 in. UL Rated flame retardant 94V-1 C w w w .tnb .c a B15 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Application Standard Finish • T o bush knockout openings in metal boxes As molded or enclosures Range Features • 0 .875 in. through 2.469 in. nominal • O ne piece construction designed to snap diameter knockout opening (1/2 in. through in place 2 in. trade size knockouts) • H igh impact strength self-extinguishing, • H Wall thickness of box or enclosure 0.095 non-dripping (per UL 94) thermoplastic in. max. up to 1 in. trade size. 0.140 in. construction max. 1-1/4 in. through 2 in. trade size Standard Material Conformity Thermoplastic rated for 105°C (221°F) UL 514B application CSA C22.2 No. 18.3 3210 Series NFPA 70-2008 (ANSI) C Knockout Bushings A For use in Wall Trade A B C D Cat. No. KO* Thickness of Elec. Size (in.) (in.) (in.) (in.) (in.) +.032/-0.16 (in.) Box (in.) 3210 1/2 0.875 1.000 0.725 3211 3/4 1.109 1.215 0.940 0.095 MAX 0.360 0.180 D B 3212 1 1.375 1.500 1.200 3213 1-1/4 1.734 1.865 1.550 0.400 0.210 3214 1-1/2 1.984 2.240 1.760 0.140 MAX One-piece knockout bushing quickly snaps into outlet box, switch box, 0.530 0.310 or other enclosure left vacant by wiring modifications or maintenance 3215 2 2.469 2.740 2.245 changes. Provides smooth, rounded insulation surface for easy wire * Per UL and NEMA standards pulling. Easily installed by hand, they are available to fit 1/2 in. through Material: Thermoplastic 2 in. knockouts. UL Listed 105°C. High impact thermoplastic. Flammability classification of 94V-1 Per UL 94 Service temperature: -40°C to 105°C ® INSULINER Sleeves Dimensions (in.) Cat. No. Size (in.) A B 422 1/2 5/8 0.022 423 3/4 11/16 0.025 424 1 7/8 0.040 425 1-1/4 1 426-TB 1-1/2 1 0.050 427-TB 2 1-1/8 B 428-TB 2-1/2 1-1/4 A 429 3 1-1/2 430-TB 3-1/2 1-25/32 0.035 431 4 2-1/32 Slip over wires — insert into bushing — snaps into place High dielectric 433 5 2-1/2 nylon, 105°C. ® An Insuliner sleeve snapped into a regular bushing makes a CSA Listed 434 6 2-1/2 insulated bushing. For standard rigid conduit, EMT (thinwall conduit) Oxygen index >28° or any standard bushed outlet. Especially suitable for use with flexible metallic conduit. Converts ordinary bushing to code approved insulated bushing without disturbing wiring. w w w .tnb .c a B16 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Knockout Plugs Application Range • T o bush knockout openings in metal boxes or enclosures • 0.875 in. through 2.469 in. nominal diameter knockout opening (1/2 in. through 2 in. trade size knockouts) Features • W all thickness of box or enclosure • O ne piece construction designed to snap in place 0.095 in. max. up to 1 in. trade size • H igh impact strength self extinguishing non-dripping 0.140 in. max. 1-1/4 in. through 2 in. trade size (per UL 94) thermoplastic construction Conformity Standard Material UL 514B Thermoplastic rated for 105°C (221ºF) application CSA C22.2 No. 18.3 Standard Finish NFPA 70-2008 (ANSI) As molded Dimensions (in.) Knockout Cat. No. Trade Size (in.) A B 1451 1/2 1.060 1452 3/4 1.300 0.400 B 1453 1 1.590 1454 1-1/4 1.860 0.450 A 1455 1-1/2 2.240 0.570 105°C rated by UL Made from flame retardant, non-dripping 1456 2 2.740 thermoplastic. Wall thickness of electrical box 0.095 max. Meets Coast Guard Regulation CB293 Pennies — Steel Cat. No. Size (in.) 815-TB 1/2 816 3/4 817 1 818 1-1/4 819 1-1/2 820 2 821 2-1/2 822 3 A penny under a bushing will seal the end of the conduit during 824-TB 3-1/2 construction. Made to fit any bushing. Completely salvageable. 823 4 UL not applicable w w w .tnb .c a B17 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings ® Plug, Conduit, Connectors (Push-Penny Plugs) Application Conformity • T o plug open end of conduit or fitting in order to prevent ingress CSA C22.2 No. 18 of trash, dirt or moisture during construction and remodeling ANSI C80.4 Features NFPA 70-2008 (ANSI) • W ide range of application; can be used with rigid metal conduit, NEMA FB-1 intermediate metal conduit, electrical metallic tubing, all connectors CEC Rule: 12-3024 and all bushings “Unused openings in boxes, cabinets and fittings shall be effectively • D esigned to stand up to normal handling and is functionally closed by plugs or plates affording protection substantially equivalent unaffected by moisture to that of the wall of the box, cabinet or fittings.” Standard Material Polyethylene Standard Finish As molded ® Bushings and Push-Penny Plugs Assembly consist of Cat. No. Size (in.) A (in.) Bushing Push-Penny 1460 1/2 1-1/32 122 1470-TB A 1461 3/4 1-9/32 123 1471 1462 1 1-19/32 124 1472 1463 1-1/4 1-15/16 125 1473 1464 1-1/2 2-3/16 126 1474 1465* 2 2-21/32 127 1475 * Maleable Iron Available in Aluminum Add suffix AL to Cat. No. ® Push-Penny Plugs Cat. No. Size (in.) 1470-TB 1/2 1471 3/4 1472 1 1473 1-1/4 1474 1-1/2 1475 2 1476* 2-1/2 1477* 3 1478* 3-1/2 1479* 4 *Not CSA Certified UL not applicable w w w .tnb .c a B18 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Application 1942 Series Electro-zinc Plated & Chromate Coated • T o effectively bush factory or field-punched, cut, or drilled holes in 842AL Series Degreased metal boxes or enclosures Range 1942 & 842AL Series • T o couple boxes back-to-back 1/2 in. through 6 in. Features All hub threads straight pipe (NPS) • Rugged construction Conformity • I nsulator curled over to: Bush conductors entering/leaving at NPS Threads UL 514B any angle. Reduce wire pull effort. Protect threads against damage CSA C22.2 No. 18.3 in handling Federal Specification W-F-408 Standard Material ANSI C80.4 1942 Series NFPA 70-2008 (ANSI) Body 1/2in.-Steel 1942 Series NEMA FB-1 3/8 in., 3/4 in. through 6 in. - Malleable Iron 842AL Series Federal Standard H-28 (Threads) Insulator Nylon (Non Insulated) 842AL Series All Copper-free Aluminum (less than 0.4% copper) ® Standard Finish CHASE Nipples Cat. No. Dimensions (in.) Size (in.) Stl. or M.I. Alum. A B 841TB — 3/8 13/16 7/16 842TB 842ALTB† 1/2 15/16 11/32 843TB 843ALTB 3/4 1-3/16 11/32 844 844AL† 1 1-7/16 21/32 Steel, malleable iron or aluminum 845 845AL† 1-1/4 1-3/4 3/4 1-1/2 2-1/16 13/16 846 846AL 2 2-1/2 31/32 847 847AL 2-1/2 3-1/16 1-1/16 848 848AL 3 3-13/16 1-3/16 849 849AL 850 850AL 3-1/2 4-3/8 1-5/16 851 851AL 4 4-3/4 1-5/16 B 853 853AL 5 5-7/8 1-5/16 854 854AL 6 6-15/16 1-3/8 A † Not UL Listed ® CHASE Nipples – Nylon Insulated Dimensions (in.) Cat. No. Size (in.) A B C 1942 1/2 15/16 1/2 19/32 1943 3/4 1-3/16 17/32 23/32 1944 1 1-7/16 21/32 7/8 Steel or malleable iron 1945 1-1/4 1-3/4 25/32 1-1/32 1946 1-1/2 2-1/16 13/16 1-3/32 1947 2 2-9/16 31/32 1-11/32 1948 2-1/2 3-1/16 1-1/16 1-7/16 3 3-13/16 1-3/16 1-19/32 1949 3-1/2 4-3/8 1-5/16 1-25/32 1950 C 4 4-5/8 1-5/16 1-13/16 1951 B 5 5-29/32 1-5/16 1-13/16 1953 A 1954 6 6-13/16 1-3/8 1-7/8 w w w .tnb .c a B19 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings ® Threaded Hubs (Bullet Hubs) for Threaded Rigid Metal Conduit/IMC/PVC Coated Rigid Metal Conduit Application • P VC coated 485 Series (A) • T o connect threaded metal conduit (1) P rotects fitting from extremely (ferrous rigid/nonferrous rigid/PVC coated/ corrosive surroundings without or intermediate metal) to a threadless affecting integrity of electrical Predetermined opening in a box or enclosure in outdoor grounding path (F) Compression (B) or indoor location exposed to continuous or (2) Provided with overlapping sleeve intermittent moisture for additional seal (G) • T o positively bond conduit to box Canadian Electric Code Rule 10-602 states (C) or enclosure that, “Where dissimilar metals cannot be (E) (D) avoided at bonding connections as indicated Features in Rule 2-112 (2). Connections shall be made • R ugged steel/malleable iron/copper-free using methods or material that will minimize aluminum construction. deterioration from galvanic action”. 370 Series • T apered internal threads for watertight/ 370AL Series Joint Industrial Council (JIC) Electrical Stan- dust tight union (A) dards also forbid dissimilar metals in contact • T hreads relieved to prevent bottoming of for the same reason and require that the conduit ensuring sound assembly (B) fittings for metal conduit be of malleable iron (G) • R ecessed sealing ring at box end. or ductile iron and have impact strength com- Captive sealing ring (C) parable to that of the conduit. • H ardened steel/malleable iron/copper-free (A) “Copper-free Aluminum” aluminum locknuts designed to • Copper-free aluminum castings (F) provide high quality ground continuity; for fittings have a maximum of 0.4% extended reach of locknut permits copper. The most detrimental effect of clamping on thin boxes and enclosures (D) higher percentage of copper on (B) • I nsulated throat protects conductors, aluminum base alloy is its decrease in cor- (G) prevents abrasion and thinning of rosion resistance. conductor insulation, reduces wire (C) pull effort (E) • S uitable for hazardous location use (E) (D) per following: (1) C lass II, Division 1 Groups E, F, G, 485 Series CEC Rule 18-202 Class II, Division 2 Groups E, F, G, CEC Rule 18-252 Class III, Division 1 Rule 18-302 Class III, Division 2 Rule 18-352 w w w .tnb .c a B20 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings ® Threaded Hubs (Bullet Hubs) for Threaded Rigid Metal Conduit/IMC/PVC Coated Rigid Metal Conduit (cont’d) Standard Material 370-485 Series 370AL Series Body 1/2 in. thru 1 in. Steel All Copper-Free Aluminum 1-1/4 in. thru 6 in. Malleable Iron Locknut 1/2 in. thru 2 in. Steel (hardened) 1/2 in. thru 2 in. Steel (hardened) 2-1/2 in. thru 6 in. Malleable Iron 2-1/2 in. thru 4 in. Copper-free Aluminum Screws Steel (hardened) ‘O’ Ring Buna N Insulator Nylon Coating PVC Standard Finish 370 Series 370AL Series 485 Series Hub Electro-zinc Plated As Cast PVC — Outside Chromate Coated Electro-zinc Locknuts All Ferrous locknuts Plated Chromate Electro-Zinc Plated Coated-Inside and Chromate Coated Screws All Electro-Zinc Plated & Chromate Coated Range 1/2 in. thru 6 in. Conduit 370 Series 1/2 in. thru 4 in. Conduit 370AL & 485 Series All hub threads — straight pipe All female threads — taper pipe (NPT) Conformity UL 514B CSA 22.2 No. 18.3 ANSI C80.4 NFPA 70-2008 (ANSI) NEMA FB-1 JIC EGP1; JIC EMP 1 Federal Specification W-F-408 Federal Standard H-28 (Threads) w w w .tnb .c a B21 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings † Steel/Malleable Iron and Aluminum Hub Fittings Cat. No. Dimensions (in.) Wall Thk. Size (in.) Max. (in.) Stl. or M.I. Alum.** A B C 1/2 1-3/8 1-5/16 3/4 370 370AL 3/4 1-5/8 1-3/8 7/8 371 371AL 1 2-3/32 1-23/32 1-7/32 372 372AL 1-1/4 2-9/16 2 1-11/32 5/16 373 373AL 1-1/2 3-3/32 2 1-11/32 374 374AL 2 3-5/8 1-31/32 1-11/32 375 375AL Nylon insulated 2-1/2 4-1/8 2-21/32 1-15/16 376 — Aluminum, steel, or malleable iron (steel through 1 in.). With Neoprene “O” Ring provides a watertight threaded hub on 3 5 2-31/32 2 377 — enclosures. UL Listed 105°C. 378 — 3-1/2 5-9/16 3-1/8 2-1/8 379-TB — 4 6-9/16 3-1/8 2-1/8 1/2 381-TB — 5 8 4 2-3/16 382-TB — 6 9-3/16 4 2-3/16 C A ** Aluminum not available with insulated throat † UL Listed raintight and CSA Certified watertight and dust tight B ® Bullet Hub Fittings with Bonding Locknut – Nylon Insulated Cat. No. Size (in.) Description 401 1/2 402 3/4 403-TB 1 Available in steel or malleable iron 407 2-1/2 Supplied with 106 Series bonding nut. Tem perature rating: 105°C. 408 3 409 3-1/2 410-TB 4 CSA certified watertight and dust tight w w w .tnb .c a B22 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings PVC Coated Hub for Rigid Conduit Dimensions (in.) Cat. No. Size (in.) A B C 485 1/2 1-21/64 2-1/8 1-7/8 486 3/4 1-19/32 2-3/8 2-1/8 1 1-27/32 2-3/4 2-3/8 487 Steel or malleable iron (steel thru 1-1/4 in.) 488 1-1/4 2-15/32 3-3/8 3-1/8 489 1-1/2 2-29/32 3-5/8 3-1/2 B PVC Plastic 2 3-3/8 3-3/4 4 Locknut 490 Coating 2-1/2 3-27/32 4 4-1/2 491 492 3 4-21/32 4-5/8 5-3/8 NFS Thread 493 3-1/2 5-9/64 4-13/16 5-7/8 C A 4 5-3/4 4-9/16 6-7/16 494 *485 Series are CSA Certified Watertight and Dustight for Ordinary Locations Insulator Sealing ring ® Spacing Chart for Bullet Hubs Min. Space from Center to Center Spacing KO Center of Conduit Sizes (in.) Diameter Bullet® Hub to Wall Min. (in.) 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 of Box (in.) 1/2 1-7/16 1-5/8 1-3/4 2-1/8 2-3/8 2-5/8 2-7/8 3-5/16 3-1/2 3-7/8 3/4 7/8 3/4 — 1-3/4 1-7/8 2-1/4 2-1/2 2-3/4 3 3-1/2 3-3/4 4-1/8 7/8 1-1/8 1 — — 2 2-3/8 2-5/8 2-7/8 3-1/8 3-5/8 3-7/8 4-1/4 1-1/8 1-3/8 1-1/4 — — — 2-11/16 2-15/16 3-1/4 3-1/2 4 4-1/4 4-1/2 1-3/8 1-3/4 1-1/2 — — — — 3-1/8 3-1/2 3-3/4 4-1/8 4-3/8 4-3/4 1-5/8 2 2 — — — — — 3-3/4 4 4-1/2 4-3/4 5 1-7/8 2-1/2 2-1/2 — — — — — — 4-1/4 4-3/4 5 5-3/8 2-1/8 3 3 — — — — — — — 5-1/8 5-3/8 5-3/4 2-5/8 3-5/8 3-1/2 — — — — — — — — 5-5/8 6 2-7/8 4-1/8 4 — — — — — — — — — 6-1/4 3-1/4 4-5/8 ® T&B Hub Centerline Spacing Chart Conduit Trade Size 1/2 (in.) 3/4 (in.) 1 (in.) 1-1/4 (in.) 1-1/2 (in.) 2 (in.) 2-1/2 (in.) 3 (in.) 3-1/2 (in.) 4 (in.) 5 (in.) 6 (in.) (in.) 1/2 1-9/16 3/4 1-43/64 1-25/32 1 1-27/32 1-61/64 2-1/8 1-1/4 2-1/32 2-9/64 2-5/16 2-1/2 1-1/2 2-7/32 2-21/64 2-1/2 2-11/16 2-7/8 2 2-15/32 2-37/64 2-3/4 2-15/16 3-1/8 3-3/8 2-1/2 2-23/32 2-53/64 3 3-3/16 3-3/8 3-5/8 3-7/8 3 3-1/32 3-9/64 3-5/16 3-1/2 3-11/16 3-15/16 4-3/16 4-1/2 3-1/2 3-11/32 3-21/64 3-5/8 3-13/16 4 4-1/4 4-1/2 4-13/16 5-1/8 4 3-19/32 3} 3-7/8 4-1/16 4-1/4 4-1/2 4-3/4 5-1/16 5-3/8 5-5/8 5 4-9/32 3-25/64 4-9/16 4-3/4 4-15/16 5-3/16 5-7/16 5-3/4 6-1/16 6-5/16 7 6 4-11/16 4-51/64 4-31/32 5-5/32 5-11/32 5-19/32 5-27/32 6-5/32 6-15/32 6-23/32 7-13/32 7-13/16 Nearest obstruction to center of hub 27/32 61/64 1-1/8 1-5/16 1-1/2 1-3/4 2 2-5/16 2-5/8 2-7/8 2-9/16 3-31/32 w w w .tnb .c a B23 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings ® The T&B Hub Never before has a single hub fit like this one. Designed for unequalled performance. The innovative ® engineering of the T&B Hub will, quite simply, raise your performance expectations for threaded hubs. The revolution in hub design is here, and the fate of our competition is sealed. 4 5 30º 3 1 6 2 Figure 1 Figure 2 Figure 3 1. Sealing ring and groove with innovative profile 2. Locknut design with periph er al slots and a 5. Precision machined tapered threads designed outperforms standard ’O’ ring design. Sealing hexagonal/angled spline spaced every 30° to create watertight union. ring is captive before installation and resists enables easy application of torque with wrench 6. Insulated throat molded from 105°C buckling or slipping during installation. The seal or hammer and screw driv er. (See Figures 2 & 3) rated thermoplastic with a flammability rating of groove is designed for op ti mum compression of 3. Sharper and deeper teeth on locknut and body 94V-O. the sealing ring. The sealing ring is designed to designed for a more penetrating bite for im- provide a complete 360° seal, even when the proved bonding to the enclosure. conduit is not perpendicular with the enclosure. (See Figure 1) 4. Hexagonal / splined body design for fast, easy installation with wrench or hammer and screwdriver. ® T&B Hub Max. Panel Throat Dia. (in.) Cat. No. Cat. No. Trade Size Thickness Dia. Zinc Aluminum (in.) A B C D (in.) E (in.) 1/2 1-7/16 1-9/16 7/8 19/32 H050-TB H050A 3/16 3/4 1-21/32 1-19/32 29/32 25/32 H075-TB H075A 1 2 1-13/16 1-1/16 1 H100-TB H100A 1-1/4 2-3/8 1-7/8 1-1/16 1-5/16 H125-TB H125A 1-1/2 2-3/4 1-7/8 1-1/16 1-17/32 H150-TB H150A 2 3-1/4 1-15/16 1-5/32 1-31/32 H200-TB H200A 2-1/2 3-3/4 2-9/16 1-9/16 2-13/32 H250-TB H250A Throat Dia. 1/4 3 4-3/8 2-21/32 1-19/32 2-31/32 E H300-TB H300A 3-1/2 5 2-23/32 1-5/8 3-13/32 H350-TB H350A 4 5-1/2 2-23/32 1-5/8 3-7/8 H400-TB H400A 5 6-7/8 3-1/32 1-15/16 4-15/16 H500-TB H500A D 6 7-11/16 3-5/32 2 6 H600-TB H600A B Material – Hub and Locknut: zinc or copper free aluminum C Insulating Throat: thermoplastic temp. rating 105°C, Flammability Rating: 94V-0 Sealing Ring Nitrile (BUNA “N”) For Chrome Plated Hubs add suffix CP (i.e. H050CP). Meets NEMA sealing requirements for NEMA 3R, 4 & 13 enclosures. A U.L. Listed and CSA Certified. CSA Certified use in hazardous locations Class I, Division 2, Class II, Groups E, F and G, Class III, Division 1, 2 and Type 4. Chrome Plated Hubs (suffix-“CP”) are rated NEMA 4X. For Aluminum Hubs add suffix A (i.e. H050A). w w w .tnb .c a B24 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings T&B Grounding Hub Dimensions (in.) Cat. No. Cat. No. Trade Size D E Dia. (in.) Zinc Aluminum (in.) Max. Panel Throat A B C Thickness Dia. 1/2 17/16 19/16 7/8 3/16 19/32 H050GR-C H050GRA-C 3/4 12-1/32 1-19/32 29/32 3/16 25/32 H075GR-C H075GRA-C 1 2 1-13/16 1-1/16 1/4 1 H100GR-C H100GRA-C 1-1/4 2-3/8 1-7/8 1-1/16 1/4 1-5/16 H125GR-C H125GRA-C 1-1/2 2-3/4 1-7/8 1-1/16 1/4 1-17/32 H150GR-C H150GRA-C Throat Dia. 2 3-1/4 1-15/16 1-15/32 1/4 1-31/32 H200GR-C H200GRA-C E 2-1/2 3-3/4 2-9/16 1-9/16 1/4 2-13/32 H250GR-C H250GRA-C 3 4-3/8 2-21/32 1-19/32 1/4 2-31/32 H300GR-C H300GRA-C 3-1/2 5 2-23/32 1-5/8 1/4 3-13/32 H350GR-C H350GRA-C D 4 5-1/2 2-23/32 1-5/8 1/4 3-7/8 H400GR-C H400GRA-C B 5 6-7/8 3-1/32 1-15/16 1/4 4-15/16 H500GR-C H500GRA-C C 6 7-11/16 3-5/32 2 5/16 6 H600GR-C H600GRA-C Material— Hub and Locknut: zinc or copper-free aluminum Insulating Throat: thermoplastic temp. rating 105°C; A flammability rating: 94V-0 Sealing Ring: Nitrile (BUNA “N”) For Chrome Plated Hubs add suffix CP (i.e. H050GRCP) For 316 Stainless Steel Hubs add suffix SST (i.e. H050GRSST) For PVC coating add suffix PVC (i.e. H050GRPVC-C) Meets NEMA sealing requirements for NEMA 3R, 4 & 13 enclosures UL Listed and CSA Certified CSA approved for use in hazardous locations: Class I, Division 2, Class II, Divisions 1 & 2, Groups E, F & G, Class III, Division 1, 2 and Type 4. T&B Grounding and Bonding Locknut Cat. No. Cat. No. Max. Trade Size A B Ground with without Conductor (in.) Dia. (in.) Height (in.) Screw (in.) Lay-In Lug Lay-In Lug Size L050GRL L050GR-C 1/2 1-1/2 13/32 #10-32 x 1/4 #10 L075GRL L075GR-C 3/4 1-11/16 13/32 #10-32 x 1/4 #10 L100GRL L100GR-C 1 2 13/32 #10-32 x 1/4 #10 L125GRL L125GR-C 1-1/4 2-3/8 15/32 1/4-20 x 1/4 #10 Grounding Locknut for Hubs L150GRL L150GR-C 1-1/2 2-3/4 15/32 1/4-20 x 5/16 #8 L200GRL L200GR-C 2 3-1/4 15/32 1/4-20 x 5/16 #8 L250GRL L250GR-C 2-1/2 3-3/4 11/16 1/4-20 x 5/16 #6 A L300GRL L300GR-C 3 4-3/8 23/32 1/4-20 x 5/16 #6 L350GRL L350GR-C 3-1/2 5 23/32 1/4-20 x 5/16 #6 L400GRL L400GR-C 4 5-1/2 23/32 1/4-20 x 5/16 #4 Material — Locknut: zinc or copper-free aluminum B For Aluminum Locknuts add suffix A. (i.e. L050GRA-C) For Chrome Plated Locknuts add suffix CP. (i.e. L050GR-CP) For 316 Stainless Steel Locknuts add suffix SST (i.e. L050GRSST). w w w .tnb .c a B25 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings T&B Bulkhead Fittings Bulkhead Fitting Cat. No. Cat. No. Trade Size (in.) Zinc Aluminum Diameter Across Flats H050BHD H050BHDA 1/2 H075BHD H075BHDA 3/4 H100BHD H100BHDA 1 1-1/4 H125BHD H125BHDA 1-1/2 H150BHD H150BHDA 2 H200BHD H200BHDA 2-1/2 H250BHD H250BHDA H300BHD H300BHDA 3 H350BHD H350BHDA 3-1/2 Thread H400BHD H400BHDA 4 H500BHD H500BHDA 5 H600BHD H600BHDA 6 Nipple Nut Thru Bulkhead Fitting Not Included Cat. No. Cat. No. Size (in.) Zinc Aluminum 1/2 H050TBF H050TBFA Height 3/4 H075TBF H075TBFA 1 H100TBF H100TBFA 1-1/4 H125TBF H125TBFA H150TBF H150TBFA 1-1/2 H200TBF H200TBFA 2 Nipple Nut Thru Bulkhead Hub Not Included Cat. No. Cat. No. Size (in.) Zinc Aluminum H050TBH H050TBHA 1/2 A H075TBH H075TBHA 3/4 NPT THREAD H100TBH H100TBHA 1 H125TBH H125TBHA 1-1/4 H150TBH H150TBHA 1-1/2 H200TBH H200TBHA 2 Trade Size (in.) Thread (in.) Height (in.) Diameter (in.) Across Flats (in.) A (in.) B (in.) NPSL THREAD B 1/2 1/2-14 1-13/32 1-7/16 1 3/4 1/2 3/4 3/4-14 1-15/32 1-11/16 1-1/4 25/32 17/32 1 1-11-1/2 1-11/16 2 1-17/32 29/32 19/32 1/4 1-1/4-11-1/2 1-25/32 2-3/8 1-27/32 29/32 21/32 1-1/2 1-1/2-11-1/2 1-13/16 2-3/4 1-1/8 29/32 21/32 2 2-1-1/2 1-27/32 3-1/4 2-5/8 15/16 21/32 2-1/2 2-1/2-8 29/32 3-3/4 3-1/8 17/32 7/8 3 3-8 2-9/16 4-3/8 3-25/32 15/16 29/32 3-1/2 3-1/2-8 2-9/16 5 4-9/32 1-3/8 7/8 4 4-8 2-9/16 5-1/2 4-27/32 1-3/8 7/8 5 5-8 2-23/32 6-5/8 5-29/32 1-15/32 7/8 6 6-8 3 7-11/16 7-1/32 1-1/2 31/32 Material— Hub, Body and Locknut: zinc or copper-free aluminum Insulating Throat: thermoplastic temp. rating 105°C; Flammability rating: 94V-0 Sealing Ring: Nitrile (BUNA “N”) For Chrome Plated Bulkhead add suffix CP w w w .tnb .c a B26 TYPE 4 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings T&B XD Expansion/Deflection Coupling for Rigid Conduit Watertight, flexible connections support movement and thermal expansion Use the XD Expansion/Deflection Coupling to join two conduit runs in applications where movement in any direction is required. The coupling provides a flexible, watertight connection, accommodating axial or parallel movement of up to 3/4 in. and angular movement of up to 30˚ from normal position. While similar fittings exist on the market today, this new and enhanced XD Expansion/Deflection Coupling ships complete with an ® Erickson conduit union to significantly reduce installation time and effort and includes a stainless steel inner sleeve for extreme durability, protection and easier wire pulling. The hubs are zinc-plated and then coated with aluminum acrylic paint for dual-layer corrosion protection. In addition, the copper ground mounting plates and internal grounding bonding jumper are entirely enclosed inside the coupling for added security against vandalism and theft. • Accommodates axial expansion/contraction up to 3/4 in., parallel deflection up to 3/4 in. and angular misalignment up to 30˚ • Suitable for use indoors, outdoors, direct buried or embedded in concrete • Watertight, flexible neoprene outer jacket, zinc-plated and acrylic-painted hubs and stainless steel tamper-proof straps ensure superior corrosion resistance — ideal for use in harsh environments Relaxed Up to 3/4 in. Up to 3/4 Up to 3/4 in. Up to 30˚ Expansion From Contraction From Angular in. Parallel Position • Copper ground mounting plates and internal grounding bonding jumper both entirely Relaxed Position Relaxed Position Deflection Deflection enclosed to safeguard against theft ® Standard Material/Finish • Includes an Erickson conduit union for faster, easier installation to reduce labor costs Hub ............... Ductile cast iron, zinc-plated • Durable stainless steel inner sleeve provides a constant, smooth inner diameter in any and aluminum acrylic painted position to ease wire pulling and protect wire insulation from damage Inner Sleeve ........ Sainless Steel • NPT threaded hubs fit standard threaded rigid metal conduit Internal Grounding • Can also be used with rigid PVC conduit with the use of standard adapters (not supplied) Bonding Jumper. . . . . Flexible copper braid A Ground Mounting B C Plates ............. Copper Hub Rings .......... Zinc-plated steel Outer Jacket ........ Molded neoprene (natural black) Jacket Straps ....... Stainless Steel D Internal flexible copper Watertight, flexible braid grounding ® neoprene outer jacket bonding jumper Erickson conduit union Stainless steel inner sleeve Dimensions (in.) Hub Size Cat. No. (in.) A B C D 1 9-13/16 8-15/32 6-7/16 3-11/32 XD3-TB 1-1/4 9-3/16 8-3/8 6-7/8 3-7/8 XD4-TB Hex gland XD5-TB 1-1/2 9-1/4 8-7/32 6-3/4 4-5/32 nut XD6-TB 2 9-3/4 8-21/32 7-1/4 4-11/16 2-1/2 11-3/4 11-3/8 8-1/2 4-7/8 XD7-TB Ground Tamperproof stainless Ground mounting plates steel jacket straps mounting plates XD8-TB 3 10-1/2 9-21/32 7-21/32 5-15/16 XD9-TB 3-1/2 10-9/16 9-3/4 7-3/4 6-5/8 4 13-3/16 11-27/32 8-7/8 7-9/32 XD010-TB Certifications/Compliances 5 14 12-15/16 11 8-9/32 XD012-TB • CSA Certified to C22.2 and UL Listed to UL 514B No. 18 XD014-TB 6 14-5/16 13-3/8 11-3/8 9-19/32 Suitable for Wet Locations (hub sizes 1 in.–2-1/2 in.) • Watertight • NEC Article 250.98 compliant w w w .tnb .c a B27 30º ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings 4" Movement Shown T&B XJG Conduit Expansion Couplings for Rigid Conduit Internal Bonding Gland Nut Jumper Easy to Install — Save Time and Money on the Job No Disassembly Required! S Suggested Specifications for expansion fittings for rigid steel or Intermediate Metal Conduit Used where: 8" Movement Shown • Raceways require expansion fittings to compensate for thermal Bonding expansion and contraction. Bushing • Expansion fittings and telescoping sections of metal raceway must be made ® Teflon Packing Ring Moving (E.I. DuPont Trademark) Conduit electrically continuous by bonding jumpers or other means (not supplied) Internal Sliding Stationary Conduit Bushing (Keyed) – Fitting will be constructed from cast iron with exterior and interior zinc plating for corrosion protection (not supplied) – The fitting shall be constructed so that disassembly is not required during installation – Fitting shall be raintight after installation – The fitting shall have an internal bonding jumper constructed of a copper braid, sized to meet UL fault Standard Material/Finish current test requirements and comply with bonding requirements — CEC article 10-612 and 10-614 Body .............. Malleable or Ductile Iron, – External bonding jumper shall not be required to comply with CEC requirements available PVC Coated – Accepted Manufacturer: Thomas & Betts — XJG-TB Series Internal Bonding Jumper. . . . . Copper Braid Exterior and B Interior Finish ....... Zinc plating, aluminum acrylic paint Packing ............ PTFE/Synthetic fiber Material C ® A (Teflon Coated) ® Teflon is a trademark of DuPont. 1 Dimensions (in.) Cat. No. Size (in.) Movement (in.) A B C 3⁄4 4 2.43 10.00 2.75 XJG24-TB XJG28-TB 3⁄4 8 2.43 14.00 2.75 XJG34-TB 1 4 2.67 10.00 2.99 Slide the fitting onto the conduit until 1 8 2.67 14.00 2.99 XJG38-TB it stops at the internal sliding bushing. Tighten and you’re ready. No parts to XJG44-TB 1-1⁄4 4 3.36 10.56 3.68 reassemble! XJG48-TB 1-1⁄4 8 3.36 14.56 3.68 2 1-1⁄2 4 3.36 10.56 3.68 XJG54-TB XJG58-TB 1-1⁄2 8 3.36 14.56 3.68 XJG64-TB 2 4 3.86 11.25 4.18 2 8 3.86 15.25 4.18 XJG68-TB 2-1⁄2 4 4.96 12.12 5.25 XJG74-TB XJG78-TB 2-1⁄2 8 4.96 16.12 5.25 With a wrench, tighten the gland nut to ® compress the Teflon packing, creating a XJG84-TB 3 4 4.96 12.12 5.25 raintight seal around the conduit. 3 3 8 4.96 16.12 5.25 XJG88-TB XJG94-TB 3-1⁄2 4 6.37 12.87 6.75 XJG98-TB 3-1⁄2 8 6.37 16.87 6.75 4 4 6.37 12.87 6.75 XJG104-TB 4 8 6.37 16.87 6.75 XJG108-TB XJG1208-TB 5 8 7.99 18.87 8.56 Also available in PVC Ocal™ coating and for EMT. Thread the next length of conduit into the other end of the fitting and tighten. You’re done! w w w .tnb .c a B28 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings T&B XJG-EMT Conduit Expansion Couplings for EMT Features • Fast and easy installation — no disassembly required • No external grounding strap needed — internal bonding jumper is protected from tampering and the environment Standard Material/Finish Body .............. Malleable or ductile iron Internal Bonding Jumper. . . . . Tinned copper braid Exterior and Interior Finish ....... Zinc plating, aluminum acrylic paint Packing ............ PTFE/Synthetic fiber material Certifications/Compliances • CSA Certified to C22.2 and UL Listed to UL 514B No. 18 Suitable for Wet Locations (hub sizes 1 in.–2-1/2 in.) A • NEC Article 250.98 compliant B Note: XJG-EMT couplings are not raintight and are for use in dr y locations only. They are UL Listed for use with aluminum EMT. A B Cat. No. Size (in.) Movement (in.) (length in.) (height in.) 3⁄4 4 17.39 2.75 XJG24-EMT XJG28-EMT 3⁄4 8 21.39 2.75 1 4 17.42 2.99 XJG34-EMT XJG38-EMT 1 8 21.42 2.99 XJG44-EMT 1-1⁄4 4 18.27 3.46 1-1⁄4 8 22.27 3.46 XJG48-EMT 1-1⁄2 4 18.69 3.68 XJG54-EMT XJG58-EMT 1-1⁄2 8 22.69 3.68 XJG64-EMT 2 4 19.04 4.18 2 8 23.04 4.18 XJG68-EMT XJG74-EMT 2-1⁄2 4 23.23 4.52 XJG78-EMT 2-1⁄2 8 27.23 4.52 3 4 24.09 5.25 XJG84-EMT 3 8 28.09 5.25 XJG88-EMT XJG94-EMT 3-1⁄2 4 28.70 6.00 XJG98-EMT 3-1⁄2 8 28.70 6.00 4 4 29.30 6.75 XJG104-EMT XJG108-EMT 4 8 29.30 6.75 w w w .tnb .c a B29 TYPE 4 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Offset Reducers Dimensions (in.) Cat. No. Cat. No. Trade Height Diameter Zinc Aluminum Size (in.) (in.) (in.) A B C D E 1-1/2-3/4 1-21/32 2-3/4 15/16 23/32 1-29/32 1-9/32 11/32 H150-075ORGR-TB H150-075ORGRA-TB 1-1/2-1 1-25/32 2-3/4 1-1/16 23/32 1-29/32 1-9/16 7/32 H150-100ORGR-TB H150-100ORGRA-TB 1-1/2-1-1/4 1-25/32 2-3/4 1-1/16 23/32 1-29/32 1-7/8 1/32 H150-125ORGR-TB H150-125ORGRA-TB 2-1/2-2 2-1/8 3-3/4 1-3/16 15/16 2-29/32 2-21/32 3/32 H250-200ORGR-TB H250-200ORGRA-TB Material— Offset Reducer and Locknut: zinc or copper-free aluminum Insulating Throat: thermoplastic temp. rating 105°C; Flammability rating 94V-0 Sealing Ring: Nitrile (BUNA “N”) For Chrome Plated Offset Reducer add suffix CP. (i.e. H150-125ORGRCP-TB) Dia. (0) C B D Height A Dia. (Ø) E Capoffs Dimensions (in.) Cat. No. Cat. No. Trade Size Height Diameter Zinc Aluminum (in.) (in.) (in.) A B C 1/2 1-13/32 1-7/16 19/32 27/32 3/16 H050CAP H050CAPA 3/4 1-15/32 1-11/16 19/32 1-1/16 3/16 H075CAP H075CAPA 1 1-11/16 2 11/16 1-5/16 1/4 H100CAP H100CAPA 1-1/4 1-25/32 2-3/8 23/32 1-21/32 1/4 H125CAP H125CAPA 1-1/2 1-13/16 2-3/4 23/32 1-29/32 1/4 H150CAP H150CAPA 2 1-27/32 3-1/4 23/32 2-3/8 1/4 H200CAP H200CAPA 2-1/2 2-9/32 3-3/4 7/8 2-29/32 1/4 H250CAP H250CAPA 3 2-9/16 4-3/8 7/8 3-1/32 11/32 H300CAP H300CAPA 3-1/2 2-9/16 5 29/32 4-1/32 11/32 H350CAP H350CAPA 4 2-9/16 5-1/2 29/32 4-1/2 11/32 H400CAP H400CAPA 5 2-23/32 6-5/8 29/32 5-9/16 11/32 H500CAP H500CAPA 6 3 7-5/8 31/32 6-5/8 11/32 H600CAP H600CAPA Material— Capoff and Locknut: zinc or copper-free aluminum B Insulating Throat: thermoplastic temp. rating 105°C; flammability rating 94V-0 Sealing Ring: Nitrile (BUNA “N”) For Chrome Plated Capoff add suffix CP. (i.e. H050CAPCP) A Height C Capoff Dia. w w w .tnb .c a B30 TYPE 4 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Threadless Fittings/Couplings for Threadless Rigid Metal Con- duit and Intermediate Metal Conduit Application Range • T o connect and effectively bond threadless • 81 23 & 8120 Series 1/2 in. through rigid metal conduit/intermediate metal 4 in. Size Conduit conduit to a box or enclosure, or to couple • 81 30 Series 1/2 in. and 3/4 in. ends of threadless conduit Size Conduit Features • A ll hub threads Straight Pipe (NPS) • S teel/Malleable Iron Construction Conformity 8123 Series • C ase hardened ring bites into conduit for UL 514B high quality continuity and grip CSA C22.2 No. 18.3 • N ylon insulator firmly secured in place ANSI C80.4 protects conductors and reduces wire NFPA 70-2008 (ANSI) pulling effort by as much as 50%; prevents thread damage in handling NEMA FB-1 • C ase hardened steel locknut or malleable Federal Specification W-F-408 iron locknut designed to provide a positive Federal Standard H-28 (Threads) bond • S uitable for concrete tight application • R aintight application 8130 Series • C apable of carrying ground fault currents up to 10,000 amps RMS (1/2 in. through 1-1/2 in. size) and 20,000 amps RMS (2 in. and above sizes) duration of current 3 cycles Standard Material Nut, Gland 1/2 in. to 1 in. Steel 1-1/4 in. to 4 in. Malleable Iron Body All Malleable Iron Ring Steel (case hardened) 8120 Series Insulator Nylon Locknut 1/2 in. thru 2 in. Steel (hardened) 2 in. thru 4 in. Malleable Iron Standard Finish Electro Zinc Plated & Chromate Coated w w w .tnb .c a B31 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Nylon Insulated Threadless Fittings Cat. No. Dimensions (in.) Conduit Size (in.) Nylon Insul. Non-Insul. A B C 8123 8121 1/2 1-11/32 1-15/16 3/4 8223 8221 3/4 1-5/8 2 3/4 B 8323 8321 1 1-7/8 2-7/16 7/8 8423 8421 1-1/4 2-3/8 2-9/16 11/16 8523 8521 1-1/2 2-5/8 2-3/4 3/4 A 8623 8621 2 3-1/4 2-15/16 27/32 8723-TB 8721 2-1/2 3-15/16 3-15/16 1-1/8 8823-TB 8821 3 4-11/16 4-1/8 1-7/32 C 8853 8851 3-1/2 5-3/16 4-1/4 1-1/8 A split steel ring with diagonal serrations grips the conduit and 8973 8971 4 5-11/16 5 1-1/8 bites into it for positive ground. Makes a permanent connection and eliminates the need for cutting a thread on the conduit. Insulation helps to guarantee continuity of service with protection of the conductor at the critical point — the fitting bushing. Malleable iron construction. Threadless Couplings Dimensions (in.) Cat. No. Size (in.) A B 1/2 1-9/32 2 8120 3/4 1-19/32 2-5/16 8220 B 1 1-7/8 2-11/16 8320 1-1/4 2-3/8 2-13/16 8420 1-1/2 2-5/8 3-5/8 8520 A 2 3-1/4 3-13/16 8620 2-1/2 3-15/16 5-3/8 8720 3 4-11/16 5-1/2 8820 Eliminate conduit threading. When tightened with a wrench they 3-1/2 5-3/16 5-1/2 8850 make a UL Listed and CSA Certified concrete-tight connection 4 5-11/16 5-1/2 8970 Malleable iron construction. Threadless Short Elbows – Nylon Insulated Dimensions (in.) Cat. No. Size (in.) A B C 8130 1/2 1-11/32 1-1/2 1/2 B 8131 3/4 1-5/8 1-3/4 9/16 8132 1 1-7/8 1-15/16 11/16 A 8134 1-1/2 2-23/32 3-1/8 13/16 C Ideal for entering enclosure or conduit body at right angles. Eliminates need to thread conduit. As with straight couplings, this fitting makes a concrete-tight connection. Malleable iron construction. w w w .tnb .c a B32 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Specifications — Set-Screw Fitting/Coupling for Threadless Rigid Metal Conduit and Intermediate Metal Conduit Application • T o connect and effectively bond threadless rigid metal conduit or intermediate metal conduit to a box or enclosure or to couple ends of threadless conduit Features • T hickwall steel or malleable iron body • H ardened hex head cup point screw to provide high quality bond • C aptive screw, will not vibrate loose • N ylon insulated throat meets and exceeds all codes requirements for bushing: (1) Prevents thinning of insulation (2) Reduces installation effort (3) Prevents first thread damage 8125 Series • C oupling provided with positive center stop • S uitable for concrete-tight application • C apable of carrying ground fault currents up to 10,000 amps RMS (1/2 through 1-1/2 in. size) and 20,000 amps RMS (2 in. and above sizes) Standard Material Body 1/2 in. thru 2 in. Steel 2-1/2 in. thru 4 in. Malleable Iron Locknut 1/2 in. thru 2 in. Steel (hardened) 2-1/2 in. thru 4 in. Malleable Iron Screw Steel (hardened) Insulator Nylon 8124 Series Standard Finish Electro Zinc Plated & Chromate Coated Conformity UL 514B CSA C22.2 No. 18.3 ANSI C80.4 NFPA 70-2008 (ANSI) NEMA FB-1 Federal Specification W-F-408 Federal Standard H-28 (Threads) w w w .tnb .c a B33 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Insulated Set-Screw Fitting Dimensions (in.) Cat. No. Conduit Size (in.) A B 8125 1/2 1-3/8 13/32 8225 3/4 1-1/2 7/16 8325 1 1-13/16 35/65 8425 1-1/4 2 5/8 B 8525-TB 1-1/2 2-5/16 5/8 8625 2 2-7/16 11/16 8725-TB 2-1/2 3-3/8 1 8825 3 3-7/16 1 8855 3-1/2 3-7/8 1-1/16 8975 4 4-3/16 1-1/8 Sizes 1/2 in.-2 in. made of steel. Sizes 2-1/2 in.-4 in. are malleable iron A Eliminate conduit threading with these set screw fittings. Captive hex head screws tighten down onto conduit for positive holding strength and ground. The fittings are furnished with insulated throats reducing wire pulling effort by as much as 50%. Approved concrete-tight. Set Screw Coupling Dimensions (in.) Cat. No. Conduit Size (in.) A 8124 1/2 2-1/2 8224 3/4 2-11/16 8324-TB 1 2-27/32 8424 1-1/4 3 8524 1-1/2 3-3/8 8624 2 3-5/8 8724-TB 2-1/2 3-7/8 8824-TB 3 4-1/4 8974 4 5-3/8 Sizes 1/2 in.-2 in. made of steel; sizes 2-1/2 in.-4 in. are malleable iron A Eliminate the need for threading conduit ends when joining rigid conduit with these set screw couplings. Captive hex head screws provide positive holding strength and ground continuity. Approved concrete-tight. w w w .tnb .c a B34 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Bushed Elbows Dimensions (in.) Cat. No. Size (in.) A B C 460TB 1/2 1-13/16 1-1/8 5/8 461TB 3/4 2-1/4 1-1/2 9/16 B 462 1 2-23/32 1-23/32 11/16 463 1-1/4 3-1/8 2-1/16 25/32 A C The noninsulated elbow has smoothly rounded shoulders to protect conductor insulation Malleable iron – Short Elbows Nylon Insulated Dimensions (in.) Cat. No. Size (in.) A B C 4290 1/2 1-7/32 1-1/4 1/2 4291 3/4 1-7/16 1-5/16 9/16 4292 1 1-23/32 1-9/16 11/16 B 4293 1-1/4 2-7/32 2-1/16 13/16 4294 1-1/2 2-15/32 2-3/16 13/16 Not UL Listed A C The integral insulation of the insulated elbow is a guarantee that the bushing of every fitting will be smooth Malleable iron B Short Elbows Dimensions (in.) A Cat. No. Size (in.) A B C 4250 1/2 1-5/16 1-1/4 7/16 4251 3/4 1-17/32 1-5/16 1/2 C 4252 1 1-13/16 1-9/16 5/8 4253 1-1/4 2-9/32 2-1/16 11/16 4254 1-1/2 2-9/16 2-3/16 11/16 When an insulated elbow is not desired, the non-insulated short elbow should be used 4255 2 3-3/32 2-9/16 11/16 Malleable iron w w w .tnb .c a B35 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings ® Threaded Couplings (ERICKSON ) Couplings for Threaded Rigid Metal Conduit and Intermediate Metal Conduit Application 675AL Series • T o couple and effectively bond threaded Bushing and Body Aluminum ends of rigid metal conduit/intermediate Ring Aluminum metal conduit where neither length of Standard Finish conduit can be rotated 674 Series: Electro Zinc Plated & Features Chromate Coated • M alleable Iron/Steel/Copper-free 675AL Series: Degreased Aluminum Construction Range • F ree fitting threads ensure easy assembly. • 6 74 Series: 3/8 in. thru 6 in. Conduit • Pe rmits conduit coupling without rotating either conduit • 6 75AL Series: 1/2 in. thru 6 in. Conduit 674 Series • P rovides rigid in-line coupling with high • A ll straight pipe threads (NPS) 675AL Series quality grounding; will not loosen under Conformity vibration UL 514B • S uitable for concrete-tight application. CSA C22.2 No. 18.3 • C apable of carrying ground fault currents up NEMA FB1 to 10,000 amps RMS (1/2 in. through ANSI C80.4 1-1/2 in. size) and up to 20,000 amps RMS (2 in. and above) (duration of fault current NFPA 70-2008 (ANSI) 3 cycles) (674 Series tested) Federal Specification W-F-408 Standard Material Federal Standard H-28 (Threads) 674 Series Bushing and Body Malleable Iron Ring Steel up to 2 in. or Malleable Iron ® ERICKSON Couplings Cat. No. Dimensions (in.) Size (in.) Mal. Iron Alum.* A B 674 — 3/8 1-1/8 1-1/8 675 675AL 1/2 1-15/32 1-1/4 676 676AL 3/4 1-9/16 1-13/32 677 677AL 1 1-29/32 1-5/8 678 678AL 1-1/4 2-3/8 1-13/16 679 679AL 1-1/2 2-5/8 1-31/32 B 680-TB 680AL 2 3-7/32 2-7/32 681 681AL 2-1/2 3-3/32 2-11/16 682 682AL 3 4-7/16 2-29/32 A 683 683AL 3-1/2 5 3 684 684AL 4 5-1/2 3-3/16 † 4-1/2 6-1/4 3-15/32 685 685AL ® 5 6-25/32 3-3/4 With an Erickson coupling, a conduit run may be completed when 686 686AL neither conduit can be turned. A conduit run may also be broken 6 8 4-1/32 687 687AL ® without taking down the whole run. Conduit joined with Erickson * Copper-free Aluminum (less than 0.4% Copper) Couplings is rigid and in line and vibration will not loosen the connections. UL Listed and CSA Certified concrete-tight † Not CSA Certified w w w .tnb .c a B36 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Panel Fitting Extensions Dimensions (in.) Cat. No. Size (in.) A B C 1/2 1-1/4 1-3/16 1-7/8 1440 3/4 1-1/4 1-13/32 1-15/16 1441 1 1-3/16 1-21/32 1-15/16 1442 C 1-1/4 1-1/4 2-1/8 2 1443 A B Ideal when longer thread length is needed. Will combine with any fitting having a male thread. Male thread of panel fitting extension is 1 in. long. Malleable iron Male Enlargers Dimensions (in.) Cat. No. Size (in.) A B C 1245 1/2 1-1/4 1-3/16 1-7/8 1246 3/4 1-1/4 1-13/32 1-15/16 A 1244 1 1-3/16 1-21/32 1-15/16 1247 1-1/4 1-1/4 2-1/8 2 B C Adapt an outlet hole to the next larger size of conduit. Rough ends of conduit caarefully covered by built-in bushing. Malleable iron Female Reducers Dimensions (in.) Cat. No. Size (in.) A B C 1250-TB 3/4 to 1/2 1-1/8 5/8 3/16 1261 1 to 1/2 1-7/16 1-7/16 3/16 1251 1 to 3/4 1-3/8 11/16 3/16 A 1262 1-1/4 to 1/2 1-13/16 21/32 3/16 1263 1-1/4 to 3/4 1-13/16 23/32 3/16 C 1252 1-1/4 to 1 1-3/4 25/32 7/32 1253 1-1/2 to 1-1/4 2 13/16 1/4 B 1254 2 to 1-1/2 2-3/8 1-3/16 9/32 1255 2-1/2 to 2 3 1-1/4 3/8 Adapt an outlet hole to the next larger size of conduit. Rough ends 1256 3 to 2-1/2 3-5/8 1-1/2 1/2 of conduit caarefully covered by built-in bushing. Malleable iron 1257 3-1/2 to 3 4-1/8 1-9/16 1/2 1258 4 to 3-1/2 4-5/8 1-3/16 1/2 w w w .tnb .c a B37 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Threaded Reducers Cat. No. Dimensions (in.) Size (in) A Stl. or M.I. Alum. 600-TB 600AL-TB 1/2 to 3/8 5/8 601-TB 601AL-TB 3/4 to 1/2 19/32 602-TB 602AL-TB 1 to 1/2 19/32 603-TB 603AL-TB 1 to 3/4 19/32 604-TB 604AL-TB 1-1/4 to 1/2 19/32 605-TB 605AL 1-1/4 to 3/4 19/32 606-TB 606AL 1-1/4 to 1 11/16 607 607AL 1-1/2 to 1/2 15/16 608 608AL 1-1/2 to 3/4 15/16 A 609 609AL 1-1/2 to 1 1-3/32 610 610AL 1-1/2 to 1-1/4 27/32 611-TB 611AL 2 to 1/2 23/32 612 612AL 2 to 3/4 1-1/16 613 613AL 2 to 1 1-1/16 For reducing the threaded opening in conduit bodies or any female threaded fitting. Smooth, built-in bushing completely covers rough 614-TB 614AL 2 to 1-1/4 1-1/16 ends of conduit. Iron or steel construction. Steel from 600-TB thru 615-TB 615AL 2 to 1-1/2 27/32 606-TB, also 614 & 615. Reducing Washers Dimensions (in.) Cat. No. Size (in.) A B 3700 3/4 to 3/8 45/64 1-3/8 3701 3/4 to 1/2 7/8 3702 1 to 3/8 45/64 3703 1 to 1/2 1-5/8 7/8 3704 1 to 3/4 1-3/32 3705-TB 1-1/4 to 3/8 45/64 3706 1-1/4 to 1/2 7/8 2 3707 1-1/4 to 3/4 1-3/32 3708 1-1/4 to 1 1-23/64 B A 3709 1-1/2 to 3/8 45/64 3710 1-1/2 to 1/2 7/8 3711 1-1/2 to 3/4 2-1/4 1-3/32 3712 1-1/2 to 1 1-23/64 3713 1-1/2 to 1-1/4 1-23/32 Washers reduce knockout hole in outlet box. Newly designed of 3714 2 to 1/2 7/8 galvanized steel. These washers, used in pairs, interlock and form a rib which centers the washers and conduit in the knockout. 3715-TB 2 to 3/4 1-3/32 3716 2 to 1 2-3/4 1-23/64 3717 2 to 1-1/4 1-23/32 3718 2 to 1-1/2 1-31/32 w w w .tnb .c a B38 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Conduit Straps for Threaded Rigid Metal Conduit and Intermediate Metal Conduit Application Standard Finish • T o support and securely fasten rigid metal 1275 Series conduit and intermediate metal to the Hot Dipped Galvanized supporting surface 1276AL Series Features As Cast • R ugged malleable iron/copper-free Range aluminum construction—snugly fits on • 1 275 Series the conduit 3/8 in. through 6 in. conduit • D esigned to prevent accumulation • 1 276AL Serie of moisture and start of corrosion on 1/2 in. through 6 in. conduit vertical run of conduit (A) 1275 Series Conformity Standard Material 1276AL Series CSA C22.2 No. 18.3 1275 Series ANSI C80.4 (A) Malleable Iron NFPA 70-2008 (ANSI) 1976AL Series Conduit Strap All copper-free Conduit aluminum Conduit Spacer Supporting Wall Pipe Straps – Malleable Iron or Aluminum Cat. No. Dimensions (in.) Screw Size (in.) Size (in.) Mal. Iron Alum. A B C † 1275 1275AL 3/8 1-15/16 19/32 1/4 † † 1276 1276AL 1/2 2-11/32 23/32 1/2 1/4 † † 1277 1277AL 3/4 2-11/16 21/32 5/8 † † 1278 1278AL 1 3-3/32 11/16 13/16 † † 1279 1279AL 1-1/4 4-1/8   13/16 29/32 5/16 † 1280 1280AL 1-1/2 4-1/2 15/16 1-17/32 3/8 1281 1281AL 2 5-3/16 1-1/8 1-1/4 7/16 B 1282* 1282AL 2-1/2 5 -15/16 1-1/2 1-3/4 1/2 1283* 1283AL 3 6-11/16 1-5/8 2-3/16 A C 1284 1284AL 3-1/2 7-19/32 1-3/4 2-3/4 1285* 1285AL 4 8-5/16 1-7/8 2-13/16 1286** 1286AL** 4-1/2 9-3/16 1-15/16 2-15/16 5/8 1287 1287AL 5 9-15/16 2 3-1/4 1288 1288AL 6 11-1/2 2-7/16 4-1/8 * May be used with EMT of same size Designed to fit each size of conduit snugly. High reinforcing ribs on † Not snap on type each side increase strength, reduce weight. Hot-dipped galvanized UL not applicable finish. ** Not CSA Certified w w w .tnb .c a B39 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Pipe Straps – Steel Dimensions (in.) Conduit Size Screw Cat. No. (in.) Size (in.) A B C † 1210C 3/8 1-15/32 3/4 11/16 1211C 1/2 2 3/4 15/16 1/4 1212C 3/4 2-5/16 3/4 1” 1213C 1 3-13/16 3/4 1-17/64 1214TB* 1-1/4 2-31/32 1-9/16 1-9/16 1215TB* 1-1/2 3-23/32 1-13/16 1-13/16 3/8 C 1216TB* 2 4-7/16 2-5/16 2-5/16 † Not snap on type UL not applicable * Not CSA Certified A B Elongated bolt hole makes alignment easy, even when holes in mounting surface are off center. Snap on features. Steel. Zinc plated. Corrosion Resistant PVC Coated Rigid Conduit Straps Dimensions (in.) Bolt Size Cat. No. Size (in.) (in.) A B C 1275CR 3/8 2 21/32 1/4 1276CR 1/2 2-13/32 25/32 1/2 1/4 1277CR 3/4 2-3/4 23/32 5/8 1278CR 1 3-5/32 3/4 13/16 1279CR 1-1/4 4-5/32 25/32 7/8 3/8 1280CR 1-1/2 4-9/16 1 1-7/32 1281CR 2 1/2 5-1/4 1-3/16 1-1/4 B UL not applicable A C Malleable iron. Designed to fit each size of conduit snugly. High reinforcing ribs on each side increase strength, reduce weight. w w w .tnb .c a B40 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Conduit Spacers for Rigid Metal Conduit, Intermediate Metal Conduit and Electrical Metal Tubing Application Standard Finish • P rovides mounting surface for 1350 Series conduit where installation requires Hot Dipped Galvanized air space between conduit and 1350AL Series supporting surface As Cast Features Range • P revents conduit rusting from wall 1350 Series 1/2 in. through 6 in. conduit condensation 1350AL Series Conformity • S pacers can be stacked one atop the other facilitating installation and CSA C22.2 No. 18.3 eliminating expensive conduit off ANSI C80.4 setting (A) NFPA 70-2008 (ANSI) • D esigned to cover wide range; marked with accurate size marking for proper positioning (B) Standard Material 1350 Series (A) Malleable Iron { 1350AL Series Copper-free aluminum 3 _ 8 _ 1 (B) 2 _ 3 4 1 w w w .tnb .c a B41 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Pipe Spacers Cat. No. Dimensions (in.) Screw Size (in.) Size Mal. Iron Alum. A B 1350 1350AL 3/8, 1/2, 3/4, 1 #7 3 7/8 1351 1351AL 1-1/4-1-1/2-2 #12 5 1-3/16 1352 1352AL 2-1/2-3 #12 9-9/16 1-3/4 1353 1353AL 3-1/2-4 #14 7-9/16 2 Conforms to CEC Rule 12-012 (5) UL not applicable A B Used with T&B conduit straps to permit space between conduit and mounting surface. Eliminates need for costly offset-bending conduit and possible corrosive moisture traps when conduit is mounted directly to a surface. Hot-dipped galvanized finish, premountable and stackable to eliminate offsetting. Pipe Spacers – PVC Coated Dimensions (in.) Conduit Screw Cat. No. Size (in.) Size A B 1350CR 1/2-3/4-1 #7 3 7/8 1351CR 1-1/4-1-1/2-2 #12 5 3/8 1352CR 2-1/2-3 #12 6-9/16 1-3/4 1353CR 3-1/2-4 #14 7-9/16 2 Conforms to CEC Rule 12-012 (5) UL not applicable B A Corrosion resistant PVC coated malleable iron. Pre-mountable, stackable to eliminate offsetting. Spacers can be stacked for offsets on wall or into outlet box. Prevents conduit rusting from wall condensation. Eliminates offsetting of conduit. w w w .tnb .c a B42 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings ® Tite-Bite Combination Couplings Armoured Cable for Threaded Rigid Dimensions (in.) Cat. No. Size (in.) A B 440 1/2 1-5/8 1-27/32 441 3/4 1-3/4 2-1/8 442 1 2 2-17/32 B A A one-piece fitting that couples armoured cable or flexible conduit ® to threaded rigid conduit. Tite-Bite wedge holds conduit securely ® with a double grip. With a Chase nipple, this fitting will connect flexible conduit to outlet boxes, allowing more wiring space in the box than the usual fitting. Malleable iron. Beam Clamps Adjustable Cat. No. Description 700TB Fits Flange 2-3/4 in. - 7-3/8 in. 703* Special Bolt and 3 Nuts Includes bolts Steel * Not CSA Certified Conduit Supports Cat. No. Size (in.) 690TB 1/2 691TB 3/4 692TB 1 693TB 1-1/4 These supports will fit any flange, tapered or straight up to 5/8 in. thick. The broad hook holds the conduit at any desired angle. Holds standard rigid conduit, EMT, or I.M.C. Malleable iron. w w w .tnb .c a B43 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding Case 1: Where threaded or threadless conduit 1 1 1 terminates into a threadless opening in a sheet CONCRETE CONCRETE RAIN metal box or enclosure with or without concentric TIGHT TIGHT TIGHT or eccentric knockouts. 2 3 4 Threadless opening in a sheet metal box Bonding jumper around concentric or eccentric rings or enclosure required by CEC Rule 10-614 8 5 Method of Bonding For 120/208 volts or 120/240 volts circuits provided no unpunched rings remain around 6 the knockout For under or over 250 volts circuits, service equipment and hazardous locations (where 5 applicable) provided no unpunched rings remain around the knockout For under or over 250 volts circuits, service 7 { equipment and hazardous locations (where applicable) with or without unpunched rings around the knockout (1) T hreaded or threadless rigid metal conduit (3) T &B Series 8125 Set Screw Fitting (6) T&B Series 106 Bonding Locknut or intermediate metal conduit (4) T&B Series 370 or H050-TB Sealing (7) T &B Series 3870 Bonding ® (2) T&B Series 8123 or 8124 Threadless Hub (Bullet Hubs) & Grounding Bushing ® ® Fittings (5) T &B Series 140 Locknuts (8) T& B Sta-Kon or Colour-Keyed lug w w w .tnb .c a B44 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (cont’d) Case 2: Where threaded or threadless conduit 1 1 1 terminates into a threaded hub in a cast metal CONCRETE CONCRETE RAIN enclosure. TIGHT TIGHT TIGHT 2 3 4 Methods of Bonding For (1) 1 20/208 or 120/240 volts circuits (CEC 10-610) Threaded hub in a cast metal (2) Over 250 volts circuits enclosure (CEC 10-610) (3) Service equipment (CEC 10-604) (4) Hazardous Locations 18-074 (where applicable) 18-124 (Class I, Zone 1) 18-160 (Class I, Zone 2) 18-218 (Class II, Division 1) 18-268 (Class II, Division 2) 18-316 (Class III, Division 1) 18-366 (Class III, Division 2) (1) Threaded or threadless rigid metal conduit or intermediate metal conduit (2) T&B Series 8123 Threadless Fitting (3) T&B Series 8125 Set Screw Fitting w w w .tnb .c a B45 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (cont’d) Case 3: Where threaded conduit terminates into a threadless opening in a sheet metal box or enclosure with no concentric or eccentric rings 1 1 remaining around knockout. 2 2 Threadless opening in a sheet metal box or enclosure 2 3 3 4 OR Method of bonding for 120/208 volt or 120/240 volts Method of bonding for over 250 volts circuits e.g. 600/347 volt systems circuits (other than service equipment). and those operating over 600 volts (other than service equipment). Note: Any of the bonding methods described for service equipment may also be used w w w .tnb .c a B46 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (cont’d) Case 3: (cont’d) Where threaded conduit terminates into a threadless opening in a sheet metal box or enclosure with no concentric or eccentric rings 1 1 1 remaining around knockout. (1) T hreaded rigid metal conduit or intermediate metal conduit 5 2 2 (2) T &B Series 142 Locknuts (3) T& B Series 122 Bushing Metallic (4) T& B Series 222 Bushing Plastic (5) T &B Series 106 Bonding Locknut (6) T&B Series 3650 Bonding Wedge Methods of Bonding 5 For (i) Over 250-volts circuit e.g. 347/600-volts 3 6 systems and those operating over 600 volts (ii) S ervice equipment OR (iii) H azardous locations where applicable 3 4 3 w w w .tnb .c a B47 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (cont’d) Case 4: Where threaded conduit terminates 5 into a threadless opening in a sheet metal box 3 or enclosure with concentric or eccentric rings remaining around knockout. Methods of bonding for under or over 250-volts, for service equipment and for hazardous locations where applicable. 4 Note: Bonding jumper required by CEC Rule 10-614 (1) Threaded rigid metal conduit or intermediate metal conduit (2) T&B Series 142 Locknuts (3) T&B Series 122 Bushing, Metallic (4) T&B Series 3650 Bonding Wedge (5) T&B Series 3870 Bonding and 2 Grounding Bushing 2 (6) T &B Typical Mechanical or Pressure Type Fitting Note: For raintight applications, a sealing 1 ring, T&B Series 5302, may be used between 1 outside of box or enclosure and the outside locknut. 6 w w w .tnb .c a B48 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (cont’d) Bonding Service Equipment Install Bonding Jumper to Assure Electrical Continuity Between (CEC Rule 10-604) Isolated Sections of Raceways (CEC Rule 10-614) 1 Threaded rigid metal conduit Service conduit Service equipment enclosure or intermediate metal conduit (Threaded rigid metal 1 Bonding required by CEC Rule 10-604 conduit or intermediate Bonding Method per CEC Rule 10-806 1 metal conduit) 1 Threaded rigid 1 metal conduit or intermediate metal Load side conduit of service equipment 2 2 Equipment Neutral Bus bonding Ground Bus jumper Grounding Electrode (i) Installing bonding jumper around unpunched concentric or Conductor Enclosure Bonding required by CEC Rule 10-606 eccentric knockouts in sheet metal box or enclosure Bonding jumper required Bonding Method per CEC Rule 10-806 [CEC Rule 10-806] by CEC Rule 10-606 CEC Rule 10-806 (ii) Installing bonding jumper in hazardous locations where 2 ‘locknut bushing’ or ‘double locknut’ type of contact is Grounding Electrode Conductor unacceptable method for bonding purposes [CEC Rule Grounding 18-074] Electrode Grounding Clamp 5 Multiple Bonding of Service Raceways Where Service Entrance Conductors are Paralleled in 4 Two or More Raceways, CEC Rule 10-614 1 Service A B C D enclosure Bus Bar Threaded Rigid Metal Conduit Ground Bus or Intermediate Metal Conduit 2 2 1 T&B Series 142 Locknut 2 T&B Series 3870 Bonding and Grounding Bushing (Threaded) Service Conduits 3 T&B Series 5262 Sealing “O” Ring Rigid metal conduit or 4 T&B Typical Bolted or Pressure Lug Intermediate Metal Conduit Suggested Specifications Grounding and bonding bushings used shall be approved for the purpose and Insulated grounding and bonding bushing (Series 3870) (1) S hall be of malleable iron/steel/aluminum construction Where code requires bonding and grounding of single or multiple metal conduits, adequately protected against corrosion or positive bonding and grounding of metal conduit to the box, enclosure or (2) Bushing insulator shall be listed or certified for 150°C/302°F auxiliary gutter, the end of the conduit shall be equipped with an insulated metallic grounding and bonding bushing such as Series 3870 manufactured application with a flammability rating of 94V-O. Insulator by Thomas & Betts. must be positively locked in place w w w .tnb .c a B49 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (cont’d) 2 Suitable for Bonding Raceway, EMT or Terminating Fitting to a sheet metal box or enclosure where Service Raceway (Rigid Metal Conduit (a) N o unpunched concentric or eccentric 1 3 or intermediate rings remain around the knockout metal conduit) (b) Ordinary locknut is unacceptable for bonding purposes such as (i) S ervice Equipment Enclosures CEC Rule 10-614 (ii) Bonding for circuits over 250 volts (where required) CEC Rule 10-614 Grounding electrode (iii) Bonding in Hazardous Locations Conductor regardless of the voltage of the Service enclosure with 3 system CEC Rule 18-074 no unpunched rings around knockout 1 Suggested Specifications Ground Bus 2 Bonding Type Locknut (Series 106) Grounding electrode Conductor Enclosure Where drawings indicate installation of a bonding type locknut to effectively bond a terminating fitting or metal conduit to a cabinet, box, enclosure or an auxiliary gutter, the locknuts installed shall be of hardened (1) T&B Series 142 Locknut steel/malleable iron construction, electro-zinc (2) T&B Series 106 Bonding Locknuts plated, such as Series 106 manufactured by (3) T&B Series 122 Bushing Thomas & Betts. w w w .tnb .c a B50 ® T&B Fittings Industrial Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (cont’d) T&B Series 3651 Acceptable Method for Bonding Following Bonding & Grounding Wedge (i) S ervice Equipment CEC Rule 10-614 (ii) B onding for Circuits over 250 volts CEC Rule 10-614 4 (iii) B onding in Hazardous Locations CEC Rule 18-074 When installed with a bonding jumper, acceptable method of bonding where unpunched rings remain around concentric or eccentric knockouts in sheet metal boxes or enclosures. [CEC Rule 10-614]. Service Raceway (Rigid Metal Conduit or Intermediate 1 Metal Conduit) Suggested Specifications 3 Bonding and Grounding Wedge (Series 3650) Service Enclosure Bonding and Grounding Wedges installed to 2 effectively bond terminating fitting or metal conduit to a cabinet, box, enclosure or an auxiliary gutter Service Equipment Bonding Jumper or to install bonding jumper around concentric or eccentric knockouts shall be of the type as manufactured by Thomas & Betts — Series 3650. Grounding electrode conductor Bonding and Grounding Wedge shall be of rugged 2 bronze/tin-plated or steel/electro-zinc plated. 1 Ground Bus Grounding electrode Conductor enclosure (Rigid Metal Conduit or Intermediate Metal Conduit) Threaded Rigid Metal Conduit or intermediate Rigid Metal Conduit 1 Sheet Metal Box or Enclosure with 4 unpunched concentric or eccentric rings 3 remaining around knockout opening 2 Equipment Bonding Jumper Phase Conductors (1) T&B Series 142 Locknut (2) T&B Series 122 Metallic Bushing (3) T&B Series 3651 Bonding & Grounding Wedge (4) T&B Pressure (crimp type) Terminal Lug w w w .tnb .c a B51

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the 1215TB?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Fittings Coupler 0.5in Female Galvanized Steel 0314

product

Fittings Coupler 0.75in Female Galvanized Steel 0315

product

Fittings Coupler 1in Female Galvanized Steel 0316

product

Fittings Coupler 1.25in Female Galvanized Steel 0317

product

Fittings Coupler 2in Female Galvanized Steel 0319

product

Fittings Coupler 2.5in Female Galvanized Steel 0320