Electronics Finder chervon right Manufacturers chervon right T chervon right TRACO POWER chervon right TSP-BAT24-072KIT
About product Specifications Datasheet FAQ

TRACO POWER TSP-BAT24-072KIT

Image of TRACO POWER TSP-BAT24-072KIT

Description

Sealed Lead Acid Battery

Part Number

TSP-BAT24-072KIT

Price

Request Quote

Manufacturer

TRACO POWER

Lead Time

Request Quote

Category

Circuit Protection »  AC-DC Power Supply

Specifications

Manufacturer

Traco Power

Manufacturers Part #

TSP-BAT24-072KIT

Industry Aliases

TSP-BAT24-072KIT

Brand

TRACO POWER

Series

TSP

Factory Pack Quantity

1

Datasheet

pdf file

selection_guide_2015.pdf

16063 KiB

Extracted Text

Selection Guide 2015 DC / DC Converters AC / DC Power Supplies Company Profile TRACO Electronic AG is a Swiss company with headquarters based in Baar, Switzerland. As a leading power supply specialist with more than 35 years’ experience we are dedicated to the design and manufacturing of high quality DC/DC and AC/DC power conversion products. TRACO markets its products worldwide under the registered trademark TRACO POWER. Our mission is to provide our customers with optimal power supply solutions in terms of performance, quality and cost for their individual application. Product Range TRACO POWER product range focuses on the following markets: Industrial & IT, Transportation & Railway, Medical & Healthcare, Automation & Control, Renewable Energy & Smart Grid. Within these markets TRACO offers one of the most comprehensive programs for standard products: DC/DC Converter Modules, 1–300 W Encapsulated AC/DC Power Modules, 2–100 W AC/DC Power Supplies (open frame / encased), 15–1000 W Power Supplies for DIN-Rail Mounting, 15–1000 W High Power Rack Converters and Inverters, up to 22 kW Detailed technical data of all our products can be downloaded from our website: www.tracopower.com Compliance, Certification and Quality Management TRACO has a high reputation for global compliance with applicable regulations and directives allowing easier implementation of our products in our customer’s applications. Our products are 100% tested and burned-in prior to shipment to guarantee full compliance to the applicable published specifications. Our safety critical products are globally certified to current standards in accordance to the applicable market segments. TRACO’s global manufacturing facilities are certified to ISO 9001/14000. Our commitment to quality is supported by a full 3 year product warranty. Commercial and Technical Support Our experienced team of application engineers has the ability to assist on any question concerning product specifications, safety standards and application. Our customers highly value our reliable two working days dedicated response policy. Distribution, Availability and Sustainability TRACO distributes its products through a global network of franchised distributors recognized in the industry for top-level design, stocking and supply chain services. The majority of products presented in our selection guide and on our web site are available ex-stock for dispatch from our central warehouse in Baar, Switzerland within 48 hours. With an extended product lifecycle TRACO provides a long-term disposability and maintenance. www.tracopower.com 1 Product Index Page DC/DC Converters Non-isolated (POL) Converters NEW TSR-0.5 Series 0.5 A Pos.-pos. circuit, SIP-3 package, LM78xx pin compat. 6 TSR-0.5SM Series 0.5 A 12 NEW Pos.-pos. circuit, SMD package TSR-1 Series 1 A 7 Pos.-pos. circuit, SIP-3 package, LM78xx pin compat. NEW TSR-1SM Series 1 A 13 Pos.-pos. circuit, SMD package NEW TSN-1 Series 1 A 8 Neg.-neg. circuit, SIP-3 package, LM79xx pin compat. TSRN-1 Series 1 A 9 Pos.-neg. circuit, SIP-3 package TSRN-1SM Series 1 A 14 Pos.-neg. circuit, SMD-package TSR-3 Series 3 A 10 Pos.-neg. circuit, SIP open frame TOS Series 6, 10, 16, 30 A 11 Pos.-pos. circuit, SMD or SIP-package SMD-Package 1 to 15 W NEW TSR-0.5SM Series 0.5 A Non-isolated (POL), pos.-pos. circuit 12 TSR-1SM Series 1 A Non-isolated (POL), pos.-pos. circuit 13 NEW TSRN-1SM Series 1 A Non-isolated (POL), pos.-neg. circuit 14 TES-1 Series 1 W Unregulated 15 TES-1V Series 1 W Unregulated, I/O-isol. 3000 VDC 16 NEW TMR-1SM 1W Regulated, 2:1 input 17 TES-2H Series 2 W Unregulated 18 TES-2N Series 2 W Regulated, 2:1 Input 19 TES-2M Series 2 W Unregulated, I/O-isol. 4000 VAC, medical safety 112 TDR-2SM Series 2 W Regulated, 2:1 input, compact overmold package 20 TDR-2WISM Series 2 W Regulated, 4:1 input, compact overmold package 21 TDR-3SM Series 3 W Regulated, 2:1 input, compact overmold package 22 TDR-3WISM Series 3 W Regulated, 4:1 input, compact overmold package 23 THL-3WISM Series 3 W Regulated, 4:1 input, EN55022 class A 24 THL-6WISM Series 6 W Regulated, 4:1 input, EN55022 class A 25 TON-15 Series 15 W Regulated, 2:1 input, open frame 26 TON-15WI Series 15 W Regulated, 4:1 input, open frame 27 SIP-Package 1 to 9 W TMA / TME Series 1 W Unregulated 28 TRA-1 Series 1 W Semi-regulated (load) 29 TMV Series 1 W Unregulated, I/O-isol. 3000 VDC 30 TMV-HI Series 1 W Unregulated, I/O-isol. 5200 VDC 31 NEW TMV-EN Series 1 W Unregulated, I/O-isol. 3000 VDC reinforced 111 TRV-1 Series 1 W Semi-regulated (load), I/O-isol. 3000 VDC 32 TMR-1 Series 1 W Regulated, 2:1 input 33 NEW TMH Series 2 W Unregulated 34 TRA-3 Series 3 W Semi-regulated (load) 35 TMR-2E Series 2 W Regulated, 2:1 input (cost optimized) 36 TMR-2 Series 2 W Regulated, 2:1 input 37 NEW TMR-2WIN Series 2 W Regulated, 4:1 input 38 TMR-3E Series 3 W Regulated, 2:1 input (cost optimized) 39 TMR-3 Series 3 W Regulated, 2:1 input, EN55022 class A 40 TMR-3HI Series 3 W Regulated, 2:1 input, I/O-isol. 3000 VDC, EN55022 A 41 TMR-3WIE Series 3 W Regulated, 4:1 input, (cost optimized) 42 TMR-3WI Series 3 W Regulated, 4:1 input 43 TMR-6 Series 6 W Regulated, 2:1 input 44 TMR-6WI Series 6 W Regulated, 4:1 input 45 NEW TMR-9 Series 8 W Regulated, 2:1 input 46 NEW TMR-9WI Series 8 W Regulated, 4:1 input 47 NEW High Performance 2 to 60 W TEL-2 Series 2 W DIP-16 package, 2:1 input 48 TDR-2 Series 2 W DIP-14 package, 2:1 input 49 TDR-2WI Series 2 W DIP-14 package, 4:1 input 50 TDR-3 Series 3 W DIP-14 package, 2:1 input 51 TDR-3WI Series 3 W DIP-14 package, 4:1 input 52 THL-3WI Series 3 W DIP-16 package, 4:1 input, EN55022 class A 53 TEM-3N Series 3 W DIP-24 package, ±10% input (cost optimized) 54 NEW TEL-3 Series 3 W DIP-24 package, 2:1 input, (cost optimized) 55 TEN-3N Series 3 W DIP-24 package, 2:1 input, EN55022 class A 56 NEW NEW TEN-3WIN Series 3 W DIP-24 package, 4:1 In., EN55022 A opt. 3000 VDC isol. 57 NEW TVN-5WI Series 5 W DIP-24 package, 4:1 input, low ripple & noise 58 TEL-5 Series 5 W DIP-24 package, 2:1 input, (cost optimized) 59 2 www.tracopower.com DC/DC Converters TEN-6N Series 6 W DIP-24 package, 2:1 input, EN55022 class A 60 TEN-6WIN Series 6 W DIP-24 package, 4:1 input, EN55022 class A 61 TEN-6WIN-HI Series 6 W DIP-24 package, 4:1 input, I/O isol. 3000 VDC 62 TEN-8 Series 8 W DIP-24 package, 2:1 input 63 TEN-8WI Series 8 W DIP-24 package, 4:1 input, EN50155 (railway) 64 NEW THD-10N Series 10 W DIP-24 package, 2:1 input, EN55022 class A 65 NEW THD-10WIN Series 10 W DIP-24 package, 4:1 input, EN55022 class A 66 NEW THL-10 Series 10 W 1“ x 1“ package, 2:1 input, EN55022 class A 67 THL-10WI Series 10 W 1“ x 1“ package, 4:1 input, EN55022 class A 68 THD-12 Series 12 W DIP-24 package, 2:1 input 69 THD-12WI Series 12 W DIP-24 package, 4:1 input, EN55022 class A 70 THD-15N Series 15 W DIP-24 package, 2:1 input, EN55022 class A 71 THD-15WIN Series 15 W DIP-24 package, 4:1 input, EN55022 class A 72 TEL-15 Series 15 W 2“ x 1“ package, 2:1 input 73 TON-15 Series 15 W Open frame, 2:1 input, EN55022 class A 26 TON-15WI Series 15 W Open frame, 4:1 input, EN55022 class A 27 THN-15 Series 15 W 1“ x 1“ package, 2:1 input 74 THN-15WI Series 15 W 1“ x 1“ package, 4:1 input 75 THN-20 Series 20 W 1“ x 1“ package, 2:1 input, EN55022 class A 76 THN-20WI Series 20 W 1“ x 1“ package, 4:1 input, EN55022 class A 77 THL-20WI Series 20 W 1“ x 1“ package, 4:1 input 78 TEN-20 Series 20 W 2“ x 1“ package, 2:1 input, EN55022 class A 79 TEN-20WIN Series 20 W 2“ x 1“ package, 4:1 input 80 TEN-20WIR Series 20 W 2“ x 1“ package, 4:1 input, EN50155 (railway) 81 NEW TMDC-20 Series 20 W Chassis-mount, screw terminal, 4:1 input, EN55022 A 82 THL-25 Series 25 W 1“ x 1“ package, 2:1 input 83 NEW THL-25WI Series 25 W 1“ x 1“ package, 4:1 input 84 TEN-30 Series 30 W 2“ x 1“ package, 2:1 input 85 TEN-30WIN Series 30 W 2“ x 1“ package, 4:1 input 86 THN-30 Series 30 W 1“ x 1“ package, 2:1 input 87 THN-30WI Series 30 W 1“ x 1“ package, 4:1 input 88 TEN-40 Series 40 W 2“ x 2“ package, 2:1 input 89 TEN-40WI Series 40 W 2“ x 2“ package, 4:1 input 90 TEN-40N Series 40 W 2“ x 1“ package, 2:1 input 91 TEN-40WIN Series 40 W 2“ x 1“ package, 4:1 input 92 TEN-40WIR Series 40 W 2“ x 1“ package, 4:1 input, EN50155 (railway) 93 NEW TMDC-40 Series 40 W Chassis-mount, screw terminal, 4:1 input, EN55022 A 94 TEN-50 Series 50 W 2“ x 1“ package, 2:1 input 95 NEW TEN-50WI Series 50 W 2“ x 1“ package, 4:1 input 96 NEW TEN-60N Series 60 W 2“ x 1“ package, 2:1 input 97 NEW TEN-60WIN Series 60 W 2“ x 1“ package, 4:1 input 98 NEW TMDC-60 Series 60 W Chassis-mount, screw terminal, 4:1 input, EN55022 A 99 High Power Modules 75 to 300 W TEP-75WI Series 75 W PCB / chassis / DIN-rail, 4:1 input, EN50155 (railway) 100 TEP-100 Series 100 W PCB, 2:1 input 101 NEW TEP-100WIR Series 100 W PCB / chassis / DIN-rail, 4:1 input, EN50155 (railway) 102 NEW TEQ-100WIR Series 100 W Chassis, 4:1 input, extend. temp., EN50155 (railway) 103 TEP-150WI Series 150 W Chassis, 4:1 input, CV/CC charact., EN50155 (railway) 104 TEP-160 Series 150 - 196 W PCB, 2:1 input 105 TEP-160WIR Series 150 - 196 W PCB, 4:1 input, EN50155 (railway) 106 NEW TEQ-160WIR Series 144 - 182 W Chassis, 4:1 input, extend. temp., EN50155 (railway) 107 TEP-200WIR Series 180 - 240 W Chassis, 4:1 input, EN50155 (railway) 108 NEW TEQ-200WIR Series 180 - 240 W Chassis, 4:1 input, extend. temp., EN50155 (railway) 109 NEW TEQ-300WIR Series 180 - 240 W Chassis, 4:1 input, CV/CC charact., EN50155 (railway) 110 www.tracopower.com 3 Reinforced Insulation - Industrial (60950) / Medical Safety (60601) TMV-EN Series 1 W SIP-package, unregulated 111 TES-2M Series 2 W SMD-package, unregulated 112 THI-2M Series 2 W DIP-16 package, unregulated 113 NEW THI-3 Series 3 W DIP-24 package, ±10% input (regulated) 114 THB-3 Series 3 W DIP-24 package, 2:1 input 115 THP-3 Series 3 W DIP-24 package, 4:1 input 116 NEW THM-3WI Series 3 W DIP-24 package, 4:1 input, 2 x MOPP 117 THB-6 Series 6 W DIP-24 package, 4:1 input 118 NEW THM-6WI Series 6 W DIP-24 package, 4:1 input, 2 x MOPP 119 THB-10 Series 10 W 2“ x 1“ package, 2:1 input 120 NEW THM-10WI Series 10 W DIP-24 package, 4:1 input, 2 x MOPP 121 High Voltage Converters THV/PHV Series 180 – 2000 VDC Shielded metal casing, remote voltage control 122 Industrial Converters, DIN-Rail Mount TCL-DC Series 12 – 60 W Slim plastic casing, EN55022 class B 123 NEW TMDC-20 Series 20 W Low profile casing, 4:1 input 82 NEW TMDC-40 Series 40 W Low profile casing, 4:1 input 94 NEW TMDC-60 Series 60 W Low profile casing, 4:1 input 99 Industrial Converters, High Power TZL Series 60 – 300 W Metal casing 124 TSC Series 150 – 5000 W 19” Plug-in / chassis / DIN-rail modules 125 TSC 19” Series 5 kW – 22 kW 19” Subracks 126 DC/AC Inverters Industrial Inverters TSD Series 200 VA - 30 kVA True sine wave output, 19” plug-in / subracks 127 AC/DC Power Supplies Open Frame Design 40 to 200 W TOP-60 Series 60 W 2“ x 4“ format 128 TOP-100 Series 100 W 2“ x 4“ format, opt. casing 129 NEW TPI 100 Series 100 W 2“ x 3“ format, reinforced isolation, ErP-ready 130 NEW TPI 150 Series 150 W 2“ x 4“ format, reinforced isolation, ErP-ready 131 TOP-200 Series 200 W 3” x 5” format 132 Encapsulated Modules 2 to 100 W NEW TMSB-2 Series 2 W PCB-mount, constant power, ErP-ready 133 NEW TMPS 03 Series 3 W 1“ x 1“ package PCB-mount, EN60335 (household) 134 NEW TMPS 05 Series 5 W 1“ x 1“ package PCB-mount, EN60335 (household) 135 TMS Series 6 – 25 W PCB / chassis 136 TMP & TMPM Series 4 – 10 W PCB-mount, ErP-ready 137 TMP Series 15 – 60 W PCB-mount 138 15 – 60 W Encapsulated Modules, Protection Class II TMP-C Series 139 TMLM Series 4 – 20 W PCB-mount 140 TML Series 20 – 40 W PCB / chassis 141 TMT Series 10 – 50 W PCB / chassis, medical safety 2 x MOOP, UL508 142 NEW TMM Series 24 – 60 W PCB-mount, medical safety 2 x MOPP, ErP-ready 143 NEW TMM-C Series 24 – 60 W Chassis-mount, medical safety 2 x MOPP, UL508 144 NEW TML-100C Series 100 W Chassis-mount, active PFC 145 TIW Series 4 – 24 W IP67 casing w. flying leads, EN60335 (household) 146 Metal Enclosure 40 to 1000 W NEW TPP 40 Series 40 W Medical safety 2 x MOPP, ErP-ready 147 NEW TPP 65 Series 65 W Medical safety 2 x MOPP, ErP-ready 148 NEW TPP 100 Series 100 W Medical safety 2 x MOPP, ErP-ready 149 NEW TPP 150 Series 150 W Medical safety 2 x MOPP, ErP-ready 150 TXM Series 15 – 300 W Cost optimized 151 TXL Series 15 – 1000 W Wide model selection (single-, dual-, triple output) 152 TXH Series 120 – 480 W Compact low profile 153 NEW TXH-600 Series 600 W Universal, active PFC, IEC-C13 line socket 154 TEX Series 120 W Outdoor power supply, all weather proof enclosure 155 DIN-Rail Mount 15 to 960 W 15 – 60 W TMP-C Series Encapsulated low profile 139 NEW TMM-C Series 24 – 60 W Encapsulated low profile, medical safety 2 x MOPP 144 TBL Series 15 – 150 W Low profile plastic casing 156 www.tracopower.com 4 4 TCL Series 24 – 240 W Slim plastic casing 157 TPC Series 30 – 120 W Compact plastic casing 158 TSPC Series 50 – 400 W Rugged metal casing, basic 159 TSP Series 72 – 600 W Rugged metal casing, high performance 160 TSP-3P Series 240 – 960 W Rugged metal casing, 3-phase input 161 TSP-WR Series 180 – 600 W Rugged metal casing, wide input (85 to 500 VAC) 162 TIS Series 50 – 600 W Low profile metal casing, int. funct. modules 164 NEW TFP Series 250 – 750 W Low profile metal casing, ErP ready 165 DIN-Rail Mount System Solutions UPS Systems NEW TSPC-240UPS Series 240 W Power supply including battery controller 166 NEW TSP-BCMU360 Series 360 W Universal controller for external power supply 166 TSP-BAT Batteries for UPS systems 163 Decoupling Modules TCL-REM 240 W Universal decoupling module, plastic casing 157 TSPC-DCM 600W Universal decoupling module, metal casing 159 Buffer Module (capacitor bank) TSP-BFM 600 W Universal buffer module for black-outs/voltage dips 163 Function Modules for TSP & TPC series TSP-BCM 12 – 48 VDC Battery controller for TSP series power supplies 163 TPC-REM 360 – 600 W Active current sharing for TPC series 163 TSP-REM 480 W Active current sharing for TSP series 163 © 2014 by TRACO ELECTRONIC AG, all rights reserved 5 www.tracopower.com 5 www.tracopower.com DC/DC Converters Non-isolated (POL) Converters TSR-0.5 Series 0.5A Compact SIP package - LM 78xx pin-compatible Very high efficiency up to 97% - No heatsink required Excellent line / load regulation Low standby current Operating temperature range –40° to 90°C Wide input voltage range 4.75 – 32 VDC Output voltages from 1.5 – 15 VDC Over-temperature protection Short circuit protection Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.4 % max. range * max. Load regulation 0.6 % max. TSR 0.5-2415 4.75 – 32 VDC 1.5 VDC 500 mA Ripple & noise <30 mVpk-pk for models up to 6.5 VDC output TSR 0.5-2418 4.75 – 32 VDC 1.8 VDC 500 mA (20 MHz BW) <40 mVpk-pk for models higher 6.5 VDC output TSR 0.5-2425 4.75 – 32 VDC 2.5 VDC 500 mA Short circuit protection continuous, automatic recovery TSR 0.5-2433 4.75 – 32 VDC 3.3 VDC 500 mA Efficiency 94 % typ. TSR 0.5-2450 6.5 – 32 VDC 5.0 VDC 500 mA Operating temperature –40 °C to +90 °C TSR 0.5-2465 8.0 – 32 VDC 6.5 VDC 500 mA range above 80 °C derating 5%/K TSR 0.5-2490 11 – 32 VDC 9.0 VDC 500 mA I/O isolation voltage non-isolated TSR 0.5-24120 15 – 32 VDC 12 VDC 500 mA TSR 0.5-241150 18 – 32 VDC 15 VDC 500 mA No load input current 5 mA typ. Casing plastic (UL 94 V-0 rated) * For an input voltage higher than 28 VDC an input capacitor 22 µF / 50 V is required Full datasheet www.tracopower.com/products/tsr05.pdf Product as SMD version: See TSR-0.5SM series page 12 Dimensions Pin 1 +Vin (Vcc) 11.5 (0.45) 2 GND 3 +Vout 123 10 1 9 3.22.54 2.54 7 (0.13) (0.1)(0.1) 6 5 7.6 (0.30) 9.3 (0.37) Bottom view 11.8 (0.47) () = Inches 6 NEW Product 2.0 (0.08) 4.1 0.5 (0.02) (0.16) 7.6 (0.30) 10.2 (0.40) 15.2 (0.6) 2.54 5.08 2.54 (0.1)(0.2) (0.1) Top view 2.54 (0.1) www.tracopower.com Non-isolated (POL) Converters DC/DC Converters TSR-1 Series 1A Compact SIP package - LM 78xx pin-compatible Very high efficiency up to 96% - No heatsink required Excellent line / load regulation Built in filter capacitors Operating temp. range –40°C to +85°C Short circuit protection Wide input operating range up to 36 VDC Low standby current Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. range * max. Load regulation 0.6 % max. TSR 1-2412 4.6 – 36 VDC 1.2 VDC 1000 mA Ripple & noise <50 mVpk-pk for models up to 6.5 VDC output TSR 1-2415 4.6 – 36 VDC 1.5 VDC 1000 mA (20 MHz BW) <75 mVpk-pk for models higher 6.5 VDC output TSR 1-2418 4.6 – 36 VDC 1.8 VDC 1000 mA Short circuit protection continuous, automatic recovery TSR 1-2425 4.6 – 36 VDC 2.5 VDC 1000 mA Efficiency 94 % typ. TSR 1-2433 4.75 – 36 VDC 3.3 VDC 1000 mA Operating temperature –40 °C to +85 °C TSR 1-2450 6.5 – 36 VDC 5.0 VDC 1000 mA range above 60 °C derating 2.4 %/K TSR 1-2465 9.0 – 36 VDC 6.5 VDC 1000 mA I/O isolation voltage non-isolated TSR 1-2490 12 – 36 VDC 9.0 VDC 1000 mA TSR 1-24120 15 – 36 VDC 12 VDC 1000 mA No load input current 1 mA typ. TSR 1-24150 18 – 36 VDC 15 VDC 1000 mA Casing plastic (UL 94 V-0 rated) Full datasheet www.tracopower.com/products/tsr1.pdf * For an input voltage higher than 32 VDC an input capacitor 22 µF / 50 V is required Product suitable for negative output voltage: See TSRN-1 series page 9 (trough hole) See TSRN-1SM series page 14 (SMD) Dimensions Pin 1 +Vin (Vcc) 11.5 (0.45) 2 GND 3 +Vout 123 10 1 9 3.22.54 2.54 7 (0.13) (0.1)(0.1) 6 5 7.6 (0.30) 9.3 (0.37) Bottom view 11.8 (0.47) () = Inches 7 2.0 (0.08) 4.1 0.5 (0.02) (0.16) 7.6 (0.30) 10.2 (0.40) 15.2 (0.6) 2.54 5.08 2.54 (0.1)(0.2) (0.1) Top view 2.54 (0.1) www.tracopower.com DC/DC Converters Non-isolated (POL) Converters TSN-1 Series 1A Negative input to negative output Pin compatible with LM79xx linear regulators High efficiency up to 96% - No heatsink required Operating temp. range –40°C to +85°C Protection against overload, short circuit and over–temperature Wide input range up to -32 VDC Low standby current Specifications Models Order code Input voltage Output voltage Output current Line regulation 1.0 % max. range * max. Load regulation 0.6 % max. TSN 1-2450 -7.0 – -32 VDC -5.0 VDC 1000 mA Ripple & noise <75 mVpk-pk for models up to 5.2 VDC output TSN 1-2452 -7.0 – -32 VDC -5.2 VDC 1000 mA (20 MHz BW) <100 mVpk-pk for models higher 5.2 VDC output TSN 1-1260 -8.0 – -32 VDC -6.0 VDC 1000 mA Short circuit protection continuous, automatic recovery TSN 1-2480 -10.5 – -32 VDC -8.0 VDC 1000 mA Efficiency 92 % typ. TSN 1-2490 -11.5 – -32 VDC -9.0 VDC 1000 mA Operating temperature –40 °C to +85 °C TSN 1-24120 -15 – -32 VDC -12 VDC 1000 mA range above 70 °C derating 2.7 %/K TSN 1-24150 -18 – -32 VDC -15 VDC 1000 mA I/O isolation voltage non-isolated * Order code for angular-pin, add suffix -A No load input current -3 mA typ. Casing plastic (UL 94 V-0 rated) Full datasheet www.tracopower.com/products/tsn1.pdf Dimensions Straight pin version Angular pin version (suffix A) Pin 0.5 (0.02) 0.5 (0.02) 1.5 (0.06) 1 GND Bottom view 2 –Vin 3 –Vout Bottom view 0.3 (0.01) 11.7 (0.46) 11.7 (0.46) 123 12 3 3.3 2.54 2.54 (0.13) (0.1)(0.1) 3.3 2.54 2.54 (0.13) (0.1)(0.1) () = Inches 8 NEW Product 0.3 (0.01) 4.1 0.5 (0.02) 3.1 (0.12) (0.16) 16.5 (0.65) 7.5 (0.30) 0.5 (0.02) 4.1 3.0 (0.11) (0.16) 16.5 (0.65) 7.5 (0.30) www.tracopower.com Non-isolated (POL) Converters DC/DC Converters TSRN-1 Series 1A Suitable for positive to negative output circuit SIP-package fits existing TO-220 footprint Pin compatible with LMxx linear regulators Built in filter capacitors Operation temp. range –40°C to +85°C No heat-sink required Over-temperature protection Short circuit protection Wide input range up to 42 VDC Excellent line / load regulation Low standby current Specifications Models 1) Order code Input voltage Output voltage Output current Line regulation 0.2 % max. 2) straight pins range max. Load regulation 1.0 % typ. Negative output circuit Output voltage set 2.0 % typ. TSRN 1-2415 4.6 – 32 VDC -1.5 VDC 600 mA accuracy TSRN 1-2418 4.6 – 32 VDC -1.8 VDC 600 mA Ripple & noise 1.5 – 6.5 VDC output models: <50 mVpk-pk (20 MHz BW) TSRN 1-2425 4.6 – 32 VDC -2.5 VDC 600 mA 9.0 – 15.0 VDC output models: <75 mVpk-pk (20 MHz BW) 4.6 32 VDC TSRN 1-2433 – -3.3 VDC 600 mA Short circuit protection continuous, automatic recovery 6.5 31 VDC TSRN 1-2450 – -5.0 VDC 400 mA Efficiency 85 % typ. TSRN 1-2465 8.0 – 29 VDC -6.5 VDC 300 mA Operating temperature –40 °C to +85 °C TSRN 1-2490 10.5 – 27 VDC -9.0 VDC 300 mA range above 70 °C derating 2.7 %/K TSRN 1-24120 13.5 – 24 VDC -12 VDC 300 mA I/O isolation voltage non-isolated TSRN 1-24150 16.5 – 21 VDC -15 VDC 200 mA No load input current 2.0 mA typ. Positive output circuit TSRN 1-2415 4.6 – 42 VDC 1.5 VDC 1000 mA Casing plastic (UL 94 V-0 rated) TSRN 1-2418 4.6 – 42 VDC 1.8 VDC 1000 mA Full datasheet www.tracopower.com/products/tsrn1.pdf TSRN 1-2425 4.6 – 42 VDC 2.5 VDC 1000 mA TSRN 1-2433 4.6 – 42 VDC 3.3 VDC 1000 mA TSRN 1-2450 6.5 – 42 VDC 5.0 VDC 1000 mA TSRN 1-2465 8.0 – 42 VDC 6.5 VDC 1000 mA TSRN 1-2490 10.5 – 42 VDC 9.0 VDC 1000 mA TSRN 1-24120 13.5 – 42 VDC 12 VDC 1000 mA TSRN 1-24150 16.5 – 42 VDC 15 VDC 1000 mA 1) Order code for angular pins model suffix A. 2) For input voltage higher 36 VDC an input capacitor 22 µF / 50 V is required. Operation Negative output operation: Dimensions Dimensions GND Straight pin version Angular pin version (suffix A) +Vin 13 GND TSRN 1 C1 C2 0.5 (0.02) 0.5 (0.02) 1.5 (0.06) 2 Bottom view -Vout Bottom view 0.3 (0.01) Positive output operation: 11.7 (0.46) 11.7 (0.46) +Vin +Vout 13 TSRN 1 C1 Input Output 123 12 3 2 GND GND 3.3 2.54 2.54 (0.13) (0.1)(0.1) 3.3 2.54 2.54 (0.13) (0.1)(0.1) () = Inches 9 0.3 (0.01) 4.1 0.5 (0.02) 2.4 (0.095) (0.16) 10.2 (0.40) 7.5 (0.30) 2.3 (0.09) 0.5 (0.02) 4.1 (0.16) 10.2 (0.40) 7.5 (0.30) www.tracopower.com DC/DC Converters Non-isolated (POL) Converters TSR-3 Series 3A High performance switching regulator Suitable for positive to negative output circuit Highest efficiency up to 95 % Adjustable output voltage Remote On/Off Wide input voltage range 2.5-5.5, 4.5-14 and 10-30 VDC Output voltages from 0.6 to 15 VDC and -0.6 to -15 VDC Short circuit protection Low output ripple & noise Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. 6) adjustable max. Load regulation 0.8 % max. Positive output circuit Output voltage by external resistor. 1) TSR 3-0533 2.5 – 5.5 VDC 0.6 – 3.3 VDC 3000 mA adjustment 2) TSR 3-1250 4.5 – 14 VDC 0.6 – 6.0 VDC 3000 mA 3) Ripple & noise <75 mVpk-pk for models up to 6 VDC output TSR 3-2450 10 – 30 VDC 3.0 – 6.0 VDC 3000 mA (20 MHz BW) <150 mVpk-pk for models higher 6 VDC output 3) TSR 3-24150 10 – 30 VDC 5.0 – 15 VDC 3000 mA Short circuit protection continuous, automatic recovery Negative output circuit 4) Efficiency 93 % typ. TSR 3-1250 4.7 – 13 VDC -0.6 – -6.0 VDC 2200 mA 5) Operating temperature –40 °C to +85 °C TSR 3-2450 10 – 27 VDC -3.0 – -6.0 VDC 2200 mA 5) range above 50 °C derating 1.5 %/K TSR 3-24150 10 – 25 VDC -5.0 – -15 VDC 1200 mA I/O isolation voltage non-isolated 1) input voltage must be at least 0.5 V higher than output Standby input current 20 mA typ. 2) input voltage must be at least 2.0 V higher than output Remote On/Off shutdown input for low input current in standby operation 3) input voltage must be at least 3.0 V higher than output Casing plastic (UL 94 V-0 rated) 4) max. input voltage = 14-|Vout| 5) max. input voltage = 30-|Vout| Full datasheet www.tracopower.com/products/tsr3.pdf 6) open trim input = min. output voltage Dimensions Pin Positive output Negative output 1 Remote On/Off Remote On/Off 9.4 (0.37) for TSR 3-0533 & TSR 3-1250 2 +Vin (Vcc) +Vin (Vcc) 10.4(0.41) other models 6.0 3 GND –Vout (0.24) 4 +Vout GND 5 Trim Trim 5 1 4 x 1.70 3.7 (0.14) (4 x 0.06) () = Inches 10 3.315.5 (0.61) (0.13) www.tracopower.com Non-isolated (POL) Converters DC/DC Converters TOS Series 6 – 30 A Models with 6, 10, 16 and 30 A Programmable output voltage from 0.75 to 5.5 VDC Very high efficiency up to 96 % Remote On/Off Under-voltage lockout Over temperature protection Surface mount (SM) or SIP-version Surface mount version fully compatible with DOSA standard Specifications Specifications Models Models Order code Input voltage Output voltage Output current Line regulation 0.3 % max. SMT-version range range max. TOS 06-05SM 2.4 – 5.5 VDC 0.75 – 3.3 VDC 6 A Load regulation 0.4 % max. TOS 10-05SM 2.4 – 5.5 VDC 0.75 – 3.3 VDC 10 A Output voltage programmable by external resistor TOS 16-05SM 2.4 – 5.5 VDC 0.75 – 3.3 VDC 16 A Ripple & noise <50 mVpk-pk for 5 Vin output models TOS 30-05SM 4.5 – 5.5 VDC 0.80 – 3.6 VDC 30 A (20 MHz BW) <75 mVpk-pk for 12 Vin output models TOS 06-12SM 8.3 – 14.0 VDC 0.75 – 5.0 VDC 6 A Transient response time 50 µsec. typ. (50% load change) TOS 10-12SM 8.3 – 14.0 VDC 0.75 – 5.0 VDC 10 A Short circuit protection continuous, automatic recovery TOS 16-12SM 8.3 – 14.0 VDC 0.75 – 5.0 VDC 16 A Efficiency 93 % typ. TOS 30-12SM 6.0 – 14.0 VDC 0.80 – 3.6 VDC 30 A* Operating temperature –40 °C to +85 °C * 20 A at output voltage higher than 2.75 VDC range (for derating see datasheet) I/O isolation voltage non-isolated Order code Input voltage Output voltage Output current SIP-version range range max. Thermal protection shutdown at 125 °C TOS 06-05SIL 2.4 – 5.5 VDC 0.75 – 3.3 VDC 6 A Remote On/Off shutdown input for low input current (3 mA) TOS 10-05SIL 2.4 – 5.5 VDC 0.75 – 3.3 VDC 10 A in standby operation TOS 16-05SIL 2.4 – 5.5 VDC 0.75 – 3.3 VDC 16 A Full datasheet www.tracopower.com/products/tos.pdf TOS 30-05SIL 4.5 – 5.5 VDC 0.80 – 5.5 VDC 30 A www.tracopower.com/products/tos30.pdf TOS 06-12SIL 8.3 – 14.0 VDC 0.75 – 5.0 VDC 6 A TOS 10-12SIL 8.3 – 14.0 VDC 0.75 – 5.0 VDC 10 A TOS 16-12SIL 8.3 – 14.0 VDC 0.75 – 5.0 VDC 16 A TOS 30-12SIL 6.0 – 14.0 VDC 0.80 – 5.5 VDC 30 A* * 25 A at output voltage higher than 2.75 VDC Dimensions 6 A output Models 10A & 16A output models 4.83 4.83 4.83 4.83 7.54 *30A output models (0.19) (0.19) (0.19) (0.19) (0.30) 4.06 4.06 4.57 (0.16) (0.16) (0.18) No Pin GND Vout Prog Sens *SEQ GND Prog Vout Bottom View Bottom View On/Off On/Off Vin Vin 1.57 2.29 1.3 1.57 2.84 *ø1.6 1.3 (0.09) (0.05) (0.112) (0.074) (0.05) (0.82) (0.82) 17.52(0.69) 29.9 (1.18) 5.97 20.3(0.8) 8.28 *8.8 33.0 (1.3) (0.24) (0.33) (0.35) 6 A output Models 10A & 16A output models *30A output models 8.28 *9.7 50.8 (2.00) (0.33) (0.38) 6.65 22.9 (0.90) (0.26) 1.28 1.28 0.51 0.64 0.51 0.64 (0.05) (0.05) (0.02) 2.54 (0.1) (0.025) (0.02) (0.025) 0.70 15.24 (0.6) 1.18 *2.18 5  2.54 (5  0.10) 25.4 (1.0) 4  2.54 (4  0.10) (0.028) (0.046) (0.086) 17.78 (0.7) 20.32 (0.8) () = Inches 11 3.29 (0.13) 10.2 (0.40) 1.57 (0.82) 8.9(0.35) On/Off Vin GND Prog Vout 1.5 8.64(0.34) (0.06) 11.4 (0.45) 3.24 (0.128) 1.57 12.7 (0.50) (0.82) 10.92(0.43) On/Off Prog No Pin (*SEQ) Vin Vin GND 1.9 10.29(0.41) (0.075) *GND 13.5 (0.53) GND Vout Sens Vout Vout www.tracopower.com DC/DC Converters SMD-Package TSR-0.5SM Series 0.5A Compact SMD package High efficiency up to 97 % - No thermal layer required Excellent line / load regulation Low standby current Operating temperature range –40°C to +90°C Wide input voltage range 4.75-32 VDC Output voltages from 1.5 to 15 VDC Short circuit protection Low output ripple & noise Available in tape & reel package Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.4 % max. range * max. Load regulation 0.6 % max. TSR 0.5-2415SM 4.75 – 32 VDC 1.5 VDC 500 mA Ripple & noise <30 mVpk-pk for models up to 6.5 VDC output TSR 0.5-2418SM 4.75 – 32 VDC 1.8 VDC 500 mA (20 MHz BW) <40 mVpk-pk for models higher 6.5 VDC output TSR 0.5-2425SM 4.75 – 32 VDC 2.5 VDC 500 mA Short circuit protection continuous, automatic recovery TSR 0.5-2433SM 4.75 – 32 VDC 3.3 VDC 500 mA Efficiency 94 % typ. TSR 0.5-2450SM 6.5 – 32 VDC 5.0 VDC 500 mA Operating temperature –40 °C to +85 °C TSR 0.5-2465SM 8.0 – 32 VDC 6.5 VDC 500 mA range above 80 °C derating 5 %/K TSR 0.5-2490SM 11 – 32 VDC 9.0 VDC 500 mA I/O isolation voltage non-isolated TSR 0.5-24120SM 15 – 32 VDC 12 VDC 500 mA TSR 0.5-24150SM 18 – 32 VDC 15 VDC 500 mA No load input current 5 mA typ. Casing plastic (UL 94 V-0 rated) * For an input voltage higher than 28 VDC an input capacitor 22 µF / 50 V is required Full datasheet www.tracopower.com/products/tsr05sm.pdf Product as SIP version: See TSR-0.5 series page 6 Dimensions Pin 15.3 (0.60) 1 +Vin (Vcc) 2.57 2.54x4 (0.10) (0.10x4) 2 +Vin (Vcc) 3 GND 10 9 876 4 +Vout TOP View 5 +Vout 6 adj. 12 34 5 7 GND 1.30 (0.05) 8 GND 9 GND SEATING 10 remote On/Off S PLANE 0.55 (0.02) 0.1S () = Inches 12 NEW Product 0~4 0.44 8.8 (0.35) 9.6 (0.38) (0.02) 9.24 (0.36) 12.35 (0.49) www.tracopower.com SMD-Package DC/DC Converters TSR-1SM Series 1A Non-isolated (POL) converter Up to 96% efficiency - No thermal layer required Built in filter capacitors Operating temp. range –40°C to +85°C Short circuit protection Wide input operating range up to 36 VDC Low standby current Available in tape & reel package Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. range * max. Load regulation 0.6 % max. TSR 1-0512SM 3.0 – 5.5 VDC 1.2 VDC 1000 mA Ripple & noise 50 mVpk-pk typ. for models up to 6.5 VDC output TSR 1-0515SM 3.0 – 5.5 VDC 1.5 VDC 1000 mA (20 MHz BW) 75 mVpk-pk typ. for models higher 6.5 VDC output TSR 1-0518SM 3.0 – 5.5 VDC 1.8 VDC 1000 mA Short circuit protection continuous, automatic recovery TSR 1-0525SM 3.8 – 5.5 VDC 2.5 VDC 1000 mA Efficiency 90 % typ. TSR 1-2412SM 4.6 – 36 VDC 1.2 VDC 1000 mA Operating temperature –40 °C to +85 °C TSR 1-2415SM 4.6 – 36 VDC 1.5 VDC 1000 mA range above 65 °C derating 2.5 %/K TSR 1-2418SM 4.6 – 36 VDC 1.8 VDC 1000 mA I/O isolation voltage non-isolated TSR 1-2425SM 4.6 – 36 VDC 2.5 VDC 1000 mA TSR 1-2433SM 4.75 – 36 VDC 3.3 VDC 1000 mA No load input current 1 mA typ. TSR 1-2450SM 6.5 – 36 VDC 5.0 VDC 1000 mA Casing plastic (UL 94 V-0 rated) TSR 1-2465SM 9.0 – 36 VDC 6.5 VDC 1000 mA Full datasheet www.tracopower.com/products/tsr1sm.pdf TSR 1-2490SM 12 – 36 VDC 9.0 VDC 1000 mA TSR 1-24120SM 15 – 36 VDC 12 VDC 1000 mA TSR 1-24150SM 18 – 36 VDC 15 VDC 1000 mA * For an input voltage higher than 32 VDC an input capacitor 22 µF / 50 V is required Dimensions Pin Solder Pad Dimension 1 –Vin 5 +Vout 2.54 1.5 5.08 (0.006) (0.20) (0.10) 6 No con. 7 GND 10 9 7 6 15.2 (0.60) 9 GND 10 No con. 2.54 5.08 2.54 (0.10)( (0.20) 0.10) 1 5 10 9 7 6 10.16 (0.40) top view 15 0.5 (0.02) (0.40) 2.54 10.16 (0.10) () = Inches 13 NEW Product 0.30 (0.01) 9.3 (0.37) 7.6 (0.30) 11.8 (0.47) 9.3 (0.37) 9.7 (0.38) 12.92 (0.51) www.tracopower.com DC/DC Converters SMD-Package TSRN-1SM Series 1A Suitable for positive to negative output circuit Non-isolated (POL) converter Built in filter capacitors Remote On/Off and output trim Operation temp. range –40°C to +85°C Over-temperature protection Short circuit protection Excellent line / load regulation Wide input up to 42 VDC Low standby current Available in tape & reel package Specifications Models 1) Order code Input voltage Output voltage Output Line regulation 0.2 % max. 2) 3) range range (nominal) current Load regulation 0.6 % max. (0-100 %) Negative output circuit Output voltage see table - - TSRN 1-2433SM 4.6 – 32 VDC 1.5 --5.5 ( 3.3) VDC 600 mA adjustment - TSRN 1-2450SM 4.6 – 31 VDC 2.5 --8.0 (-5.0) VDC 400 mA Ripple & noise 1.2 - 8.0 VDC output models: <50 mVpk-pk (20 MHz BW) - - TSRN 1-2490SM 7.0 – 27 VDC 4.5 --12.6 ( 9.0) VDC 300 mA 8.1 - 15.0 VDC output models: <75 mVpk-pk (20 MHz BW) 7.0 24 VDC - TSRN 1-24120SM – -4.5 --13.5 ( 12) VDC 300 mA Short circuit protection continuous, automatic recovery 7.0 21 VDC - TSRN 1-24150SM – -4.5 --15.5 ( 15) VDC 200 mA Efficiency 85 % typ. Positive output circuit Operating temperature –40 °C to +85 °C TSRN 1-0525SM 3.0 – 5.5 VDC 1.2 – 3.6 (2.5) VDC 1000 mA range above 60 °C derating 2.0 %/K TSRN 1-2433SM 4.6 – 42 VDC 1.5 – 5.5 (3.3) VDC 1000 mA I/O isolation voltage non-isolated TSRN 1-2450SM 6.5 – 42 VDC 2.5 – 8.0 (5.0) VDC 1000 mA Remote On/Off shutdown input for low input current (1.2 mA) TSRN 1-2490SM 10.5 – 42 VDC 4.5 – 12.6 (9.0) VDC 1000 mA in standby operation TSRN 1-24120SM 13.5 – 42 VDC 4.5 – 13.5 (12) VDC 1000 mA Casing plastic (UL 94 V-0 rated) TSRN 1-24150SM 16.5 – 42 VDC 15.5 – 4.5 (15) VDC 1000 mA Full datasheet www.tracopower.com/products/tsrn1sm.pdf 1) Same order code for positive and negative output operation 2) For input voltage higher 36 VDC an input capacitor 22 µF / 50 V is required. 3) For positive output circuit, input voltage must be higher than output voltage set:>0.5V for TSRN1-0525SM and >1.5 V for other models. For negative output circuit, input voltage plus absolute output voltage set must not exceed 36 VDC (Vin + |Vout| <36 VDC) Operation Positive output operation Dimensions +Vin +Vout 15 TSRN 1SM C1 10 7,9 Remote On/O GND GND 15.2 (0.60) 2.54 5.08 2.54 (0.10) (0.20) (0.10) Negative output operation 10 9 7 6 GND top view +Vin 15 GND 15 TSRN 1SM C1 C2 2.54 10.16 (0.40) (0.10) 7,9 10 Remote On/O -Vout () = Inches 14 0.30 (0.01) 9.3 (0.37) 7.3 (0.29) 11.82 (0.47) www.tracopower.com SMD-Package DC/DC Converters TES-1 Series 1 W SMD package with industry standard footprint Single and dual output models I/O isolation 1500 VDC Operating temperature Range –40 °C to +85 °C Available in tape & reel package Specifications Models Order code Input voltage Output voltage Output current Line regulation non regulated max. Load regulation +10 %/ -5% max. TES 1-0510 3.3 VDC 300 mA Ripple & noise <120mVpk-pk (20 MHz BW) TES 1-0511 5 VDC 200 mA Short circuit protection limited 0.5 sec. TES 1-0519 9 VDC 110 mA Efficiency 80 % typ. TES 1-0512 5 VDC ± 10 % 12 VDC 85 mA TES 1-0513 15 VDC 65 mA Operating temperature –40 °C to +85 °C range above 75 °C derating 4.0 %/K TES 1-0521 ± 5 VDC ± 100 mA I/O isolation voltage 1500 VDC (60 sec.) TES 1-0522 ± 12 VDC ± 40 mA TES 1-0523 ± 15 VDC ± 35 mA Casing plastic, insert mold (UL 94-0 rated) TES 1-1211 5 VDC 200 mA Full datasheet www.tracopower.com/products/tes1.pdf TES 1-1219 9 VDC 110 mA TES 1-1212 12 VDC 85 mA TES 1-1213 12 VDC ± 10 % 15 VDC 65 mA TES 1-1221 ± 5 VDC ± 100 mA TES 1-1222 ± 12 VDC ± 40 mA TES 1-1223 ± 15 VDC ± 35 mA TES 1-2411 5 VDC 200 mA TES 1-2419 9 VDC 110 mA TES 1-2412 12 VDC 85 mA TES 1-2413 24 VDC ± 10 % 15 VDC 65 mA TES 1-2421 ± 5 VDC ± 100 mA TES 1-2422 ± 12 VDC ± 40 mA TES 1-2423 ± 15 VDC ± 35 mA Dimensions Single Output Models Dual Output Models Pin Single output Dual output 3.04 1 –Vin (GND) –Vin (GND) 3.04 (0.12) (0.12) 2 +Vin (Vcc) +Vin (Vcc) 10 7  5 4 –Vout Common 5 +Vout –Vout 12 4 5 7 +Vout 1   8 No con. 2.54 5.08 2.54 2.54 5.08 18 No con. (0.1) (0.2) (0.1) (0.1) (0.2) 16.24 (0.64) ( Magnification of A ) 13.7 (0.54) ( Magnification of A ) S SEATING PLANE S SEATING PLANE 1.5 0.1 1.5 0.1 1.5 0.1 1.5 0.1 0.60 (0.02) [0.06 0.004] [0.06 0.004] 5.5 5.5 0.60 (0.02) [0.06 0.004] [0.06 0.004] 0.15 S 5.5 5.5 0.15 S [0.22] [0.22] [0.22] [0.22] () = Inches 15 Solder Pad Dimension 1.0 min. Solder Pad Dimension (0.04) 1.0 min. (0.04) 2.54 5.08 2.54 (0.10) (0.10) (0.10) 2.54 5.08 (0.10) (0.10) R0.5 R0.5 0~4 0~4 6.7 (0.26) 8.0 (0.31) 0.3 (0.01) 7.0 0.5 11.0 0.2 11.6 (0.43 0.008) (0.28 0.02) (0.46) 1.6 (0.07) 0.25 [0.01] 0.3 6.7 (0.26) 8.0 (0.31) (0.01) 11.6 11.0 0.2 7.0 0.5 (0.46) (0.43 0.008) (0 .28 0.02) 1.6 (0.07) 0.25 [0.01] www.tracopower.com DC/DC Converters SMD-Package TES-1V Series 1 W SMD package with industry standard footprint I/O isolation 3000 VDC Single and dual output models Operating temperature range –40 °C to +85 °C Available in tape & reel package Specifications Models Order code Input voltage Output voltage Output current Line regulation non regulated max. Load regulation +10 %/ -5% max. TES 1-0510V 3.3 VDC 260 mA Ripple & noise <100mVpk-pk (20 MHz BW) TES 1-0511V 5 VDC 200 mA Short circuit protection limited 0.5 sec. TES 1-0512V 12 VDC 84 mA Efficiency 80 % typ. TES 1-0513V 5 VDC ± 10 % 15 VDC 67 mA TES 1-0521V ± 5 VDC ± 100 mA Operating temperature –40 °C to +85 °C range above 75 °C derating 4.0 %/K TES 1-0522V ± 12 VDC ± 42 mA I/O isolation voltage 3000 VDC (60 sec.) functional isolation TES 1-0523V ± 15 VDC ± 34 mA TES 1-1210V 3.3 VDC 260 mA I/O isolation capacitance 60 pF typ. TES 1-1211V 5 VDC 200 mA I/O isolation resistance >10 GOhm TES 1-1212V 12 VDC 84 mA Casing insert mold (UL 94-0 rated plastic) TES 1-1213V 12 VDC ± 10 % 15 VDC 67 mA Full datasheet www.tracopower.com/products/tes1v.pdf TES 1-1221V ± 5 VDC ± 100 mA TES 1-1222V ± 12 VDC ± 42 mA TES 1-1223V ± 15 VDC ± 34 mA TES 1-2410V 3.3 VDC 260 mA TES 1-2411V 5 VDC 200 mA TES 1-2412V 12 VDC 84 mA TES 1-2413V 24 VDC ± 10 % 15 VDC 67 mA TES 1-2421V ± 5 VDC ± 100 mA TES 1-2422V ± 12 VDC ± 42 mA TES 1-2423V ± 15 VDC ± 34 mA Dimensions Pin Single output Dual output 1 –Vin (GND) –Vin (GND) 2 +Vin (Vcc) +Vin (Vcc) 3 No con. No con. 5 –Vout Common 6 No con. –Vout 7 No con. No con. 8 +Vout +Vout 10 No con. No con. 11 No con. No con. 12 No con. No con. 8.0 (0.31) 0.33(0.01) 11.0 (0.43) 8.0 (0.31) () = Inches 16 1.82.542.542 5.08 .54 (0.07) (0.10) (0.10) (0.20) (0.10) 12 11 10 87 Top view 123 56 16.3(0.64) www.tracopower.com SMD-Package DC/DC Converters C CBB TMR-1SM Series 1 W Schem Schemee UL 60950-1 Wide 2:1 input voltage Low ripple and noise 30mVpk-pk Fully regulated outputs No minimum load required Operating temperature range –40 °C to +85 °C I/O isolation 1500 VDC Continuous short circuit protection Remote On/Off Available in tape & reel package Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation 1 % max. TMR 1-0511SM 5 VDC 200 mA Ripple & noise 30mVpk-pk typ. (20 MHz BW) TMR 1-0512SM 12 VDC 83 mA Short circuit protection continuous, automatic recovery TMR 1-0513SM 4.5 - 9.0 VDC 15 VDC 67 mA Efficiency 80 % typ. TMR 1-0522SM ± 12 VDC ±42 mA TMR 1-0523SM ± 15 VDC ± 33 mA Operating temperature –40 °C to +85 °C range above 75 °C derating 6.7 %/K TMR 1-1211SM 5 VDC 200 mA I/O isolation voltage 1500 VDC (60 sec.) TMR 1-1212SM 12 VDC 83 mA TMR 1-1213SM 9 - 18 VDC 15 VDC 67 mA Casing plastic, insert mold (UL 94-0 rated) TMR 1-1222SM ± 12 VDC ±42 mA Full datasheet www.tracopower.com/products/tmr1sm.pdf TMR 1-1223SM ± 15 VDC ± 33 mA TMR 1-2411SM 5 VDC 200 mA TMR 1-2412SM 12 VDC 83 mA TMR 1-2413SM 18 - 36 VDC 15 VDC 67 mA TMR 1-2422SM ± 12 VDC ± 42 mA TMR 1-2423SM ± 15 VDC ± 33 mA TMR 1-4811SM 5 VDC 200 mA TMR 1-4812SM 12 VDC 83 mA TMR 1-4813SM 36 - 75 VDC 15 VDC 67 mA TMR 1-4822SM ± 12 VDC ± 42 mA TMR 1-4823SM ± 15 VDC ± 33 mA Dimensions 18.9 [0.74] Pin Single output Dual output 2.54 1.8 [0.1] 12.7 [0.5] 1 –Vin (GND) –Vin (GND) [0.1] 2 Remote On/Off Remote On/Off 14 9 8 6 No con. Common 7 No con. –Vout 8 +Vout +Vout 9 –Vout Common 1 2 6 7 14 +Vin +Vin 1.00 [0.04] S SEATING PLANE 1.1 [0.04] 15.0 [0.6] 0.15 S () = Inches 17 NEW Product 0~ 4 0.25 [0.01] 8.45 [0.33] 13.7 [0.54] 8.7 [0.34] 17.2 [0.68] www.tracopower.com DC/DC Converters SMD-Package TES-2H Series 2 W SMD package with industry standard footprint Single and dual output models I/O isolation 1500 VDC Operating temperature range –40 °C to +85 °C Available in tape & reel package Specifications Models Order code Input voltage Output voltage Output current Line regulation non regulated max. Load regulation +10 %/ -5% max. TES 2-0510H 3.3 VDC 500 mA Ripple & noise <120mVpk-pk (20 MHz BW) TES 2-0511H 5 VDC 400 mA Short circuit protection limited 0.5 sec. TES 2-0512H 5 VDC ± 10 % 12 VDC 165 mA Efficiency 80 % typ. TES 2-0521H ± 5 VDC ± 200 mA TES 2-0522H ± 12 VDC ± 83 mA Operating temperature –40 °C to +85 °C range above 75 °C derating 4.0 %/K TES 2-0523H ± 15 VDC ± 66 mA I/O isolation voltage 1500 VDC (60 sec.) TES 2-1210H 3.3 VDC 500 mA TES 2-1211H 5 VDC 400 mA Casing plastic, insert mold (UL 94-0 rated) TES 2-1212H 12 VDC ± 10 % 12 VDC 165 mA Full datasheet www.tracopower.com/products/tes2h.pdf TES 2-1222H ± 12 VDC ± 83 mA TES 2-1223H ± 15 VDC ± 66 mA TES 2-2410H 3.3 VDC 500 mA TES 2-2411H 5 VDC 400 mA TES 2-2412H 24 VDC ± 10 % 12 VDC 165 mA TES 2-2422H ± 12 VDC ± 83 mA TES 2-2423H ± 15 VDC ± 66 mA Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) Single output models Dual output models 2 +Vin (Vcc) +Vin (Vcc) 4 – Vout Common 5 + Vout – Vout 7 + Vout 8 No con. 10 No con. 0.30(0.01) 0.30(0.01) 9.3 (0.37) 9.3 (0.37) 8.9 (0.35) 12.3 (0.48) 8.9 (0.35) 12.3 (0.48) () = Inches 18 3.04 2.54 5.08 (0.12) (0.10) (0.20) 85 Top view 12 4 0.6 (0.02) 13.7(0.54) 3.04 2.54 5.08 2.54 (0.12) (0.10) (0.20) (0.10) 10 7 Top view 12 4 5 0.6(0.02) 16.3(0.64) www.tracopower.com SMD-Package DC/DC Converters C CBB TES-2N Series 2 W Schem Schemee UL 60950-1 Low profile SMD package Wide 2:1 input range Fully regulated output I/O isolation 1500 VDC Operating temperature range –40 °C to +85 °C Short circuit protection Input filter to meet EN 55022, class A Available in tape & reel package Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation Single output models: 0.75 % max. TES 2N-0510 3.3 VDC 500 mA Dual output models: 2.0 % max. TES 2N-0511 5 VDC 400 mA Ripple & noise <50 mVpk-pk (20 MHz BW) TES 2N-0512 12 VDC 165 mA Conducted EMI EN55022 class A TES 2N-0513 4.5 - 9.0 VDC 15 VDC 135 mA Short circuit protection continuous, automatic recovery TES 2N-0521 ± 5 VDC ± 200 mA Efficiency 78 % typ. TES 2N-0522 ± 12 VDC ± 85 mA Operating temperature –40 °C to +85 °C TES 2N-0523 ± 15 VDC ± 65 mA range above 70 °C derating 3.5 %/K TES 2N-1210 3.3 VDC 500 mA TES 2N-1211 5 VDC 400 mA I/O isolation voltage 1500 VDC (60 sec.) TES 2N-1212 12 VDC 165 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report approvals TES 2N-1213 9 - 18 VDC 15 VDC 135 mA TES 2N-1221 ± 5 VDC ± 200 mA Casing plastic, insert mold (UL 94-0 rated) TES 2N-1222 ± 12 VDC ± 85 mA Full datasheet www.tracopower.com/products/tes2n.pdf TES 2N-1223 ± 15 VDC ± 65 mA TES 2N-2410 3.3 VDC 500 mA TES 2N-2411 5 VDC 400 mA Product with same electrical specifications available in TES 2N-2412 12 VDC 165 mA TES 2N-2413 18 - 36 VDC 15 VDC 135 mA DIP package. TES 2N-2421 ± 5 VDC ± 200 mA See TEL-2 series page 48 TES 2N-2422 ± 12 VDC ± 85 mA TES 2N-2423 ± 15 VDC ± 65 mA TES 2N-4810 3.3 VDC 500 mA TES 2N-4811 5 VDC 400 mA TES 2N-4812 12 VDC 165 mA TES 2N-4813 36 - 75 VDC 15 VDC 135 mA TES 2N-4821 ± 5 VDC ± 200 mA TES 2N-4822 ± 12 VDC ± 85 mA TES 2N-4823 ± 15 VDC ± 65 mA Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 7 No con. No con. 8 No con. Common 9 + Vout + Vout 10 – Vout – Vout 16 + Vin (Vcc) + Vin (Vcc) 0.25 13.7 (0.54) (0.01) 8.0 (0.31) 18.1 (0.71) () = Inches 19 24.0 (0.94) 1.0 (0.04) 16 10 9 top view 17 8 3.11 15.24 (0.60) 2.54 (0.12) (0.10) www.tracopower.com DC/DC Converters SMD-Package TDR-2SM Series 2 W UL 60950-1 Compact design in SMD package Wide 2:1 input voltage range Operating temperature range –40 °C to +85 °C without derating Fully regulated outputs Low ripple & noise 30 mVpk-pk No minimum load required I/O-isolation 1500 VDC Short circuit protection Remote On/Off Available in tape & reel package Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation – Single output models: 1.0 % max. TDR 2-0511SM 5 VDC 400 mA – Dual output models: 1.0 % max. TDR 2-0512SM 12 VDC 167 mA Ripple & noise 30 mVpk-pk typ. (20 MHz BW) TDR 2-0513SM 4.5 – 9 VDC 15 VDC 134 mA Short circuit protection continuous, automatic recovery TDR 2-0522SM ± 12 VDC ± 83 mA Efficiency 81 % typ. TDR 2-0523SM ± 15 VDC ± 67 mA Operating temperature –40 °C to +85 °C without derating TDR 2-1211SM 5 VDC 400 mA range TDR 2-1212SM 12 VDC 167 mA I/O isolation voltage 1500 VDC (60 sec.) TDR 2-1213SM 9 – 18 VDC 15 VDC 134 mA TDR 2-1222SM ± 12 VDC ± 83 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 approvals TDR 2-1223SM ± 15 VDC ± 67 mA Remote On/Off shutdown input for low input current (2.5 mA) TDR 2-2411SM 5 VDC 400 mA in standby operation TDR 2-2412SM 12 VDC 167 mA Casing over mold (UL 94 V-O rated) TDR 2-2413SM 18 – 36 VDC 15 VDC 134 mA TDR 2-2422SM ± 12 VDC ± 83 mA Full datasheet www.tracopower.com/products/tdr2.pdf TDR 2-2423SM ± 15 VDC ± 67 mA TDR 2-4811SM 5 VDC 400 mA Product with same electrical specifications available in TDR 2-4812SM 12 VDC 167 mA TDR 2-4813SM 36 – 75 VDC 15 VDC 134 mA DIP package. TDR 2-4822SM ± 12 VDC ± 83 mA See TDR-2 series page 49 TDR 2-4823SM ± 15 VDC ± 67 mA Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 17.2 (0.68) 2 Remote On/Off Remote On/Off 8.4 (0.33) 12.8 (0.50) 6 No con. Common 7 No con. – Vout 8 7 8 + Vout + Vout 9 6 9 – Vout Common 14 + Vin (Vcc) + Vin (Vcc) 2 14 1 () = Inches 20 1.8 2.54 10.16 2.54 (0.07) (0.1) (0.4) (0.1) 0.8 (0.03) 1.3 (0.05) top view 18.9 (0.74) www.tracopower.com SMD-Package DC/DC Converters TDR-2WISM Series 2 W UL 60950-1 Compact design in SMD package Ultra wide 4:1 input voltage range Operating temperature range –40 °C to +85 °C without derating Fully regulated outputs Low ripple & noise 30 mVpk-pk No minimum load required I/O-isolation 1500 VDC Short circuit protection Remote On/Off Available in tape & reel package Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation – Single output models: 1.0 % max. TDR 2-1211WISM 5 VDC 400 mA – Dual output models: 1.0 % max. TDR 2-1212WISM 12 VDC 167 mA Ripple & noise 30 mVp-p typ. (20 MHz BW) TDR 2-1213WISM 4.5 – 18 VDC 15 VDC 134 mA Short circuit protection continuous, automatic recovery TDR 2-1222WISM ± 12 VDC ± 83 mA Efficiency 81 % typ. TDR 2-1223WISM ± 15 VDC ± 67 mA Operating temperature –40 °C to +85 °C without derating TDR 2-2411WISM 5 VDC 400 mA range TDR 2-2412WISM 12 VDC 167 mA I/O isolation voltage 1500 VDC (60 sec.) TDR 2-2413WISM 9 – 36 VDC 15 VDC 134 mA TDR 2-2422WISM ± 12 VDC ± 83 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 approvals TDR 2-2423WISM ± 15 VDC ± 67 mA Remote On/Off shutdown input for low input current (2.5 mA) TDR 2-4811WISM 5 VDC 400 mA in standby operation TDR 2-4812WISM 12 VDC 167 mA Casing over mold (UL 94 V-O rated) TDR 2-4813WISM 18 – 75 VDC 15 VDC 134 mA TDR 2-4822WISM ± 12 VDC ± 83 mA Full datasheet www.tracopower.com/products/tdr2wi.pdf TDR 2-4823WISM ± 15 VDC ± 67 mA Product with same electrical specifications available in DIP package. See TDR-2WI series page 50 Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 17.2 (0.68) 2 Remote On/Off Remote On/Off 8.4 (0.33) 12.8 (0.50) 6 No con. Common 7 No con. – Vout 8 7 8 + Vout + Vout 9 6 9 – Vout Common 14 + Vin (Vcc) + Vin (Vcc) 2 14 1 () = Inches 21 1.8 2.54 10.16 2.54 (0.07) (0.1) (0.4) (0.1) 0.8 (0.03) 1.3 (0.05) top view 18.9 (0.74) www.tracopower.com DC/DC Converters SMD-Package TDR-3SM Series 3 W UL 60950-1 Smallest 3 Watt converter in SMD package Wide 2:1 input voltage range Operating temperature range –40 °C to +85 °C Fully regulated outputs Low ripple & noise 30 mVpk-pk No minimum load required I/O isolation 1500 VDC Short circuit protection Remote On/Off Available in tape & reel package Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation – Single output models: 1.0 % max. TDR 3-0511SM 5 VDC 600 mA – Dual output models: 1.0 % max. TDR 3-0512SM 12 VDC 250 mA Ripple & noise 30 mVpk-pk typ. (20 MHz BW) TDR 3-0513SM 4.5 – 9 VDC 15 VDC 200 mA Short circuit protection continuous, automatic recovery TDR 3-0522SM ± 12 VDC ± 125 mA Efficiency 81 % typ. TDR 3-0523SM ± 15 VDC ± 100 mA Operating temperature –40 °C to +85 °C TDR 3-1211SM 5 VDC 600 mA range above 70 °C derating 3.3%/K TDR 3-1212SM 12 VDC 250 mA I/O isolation voltage 1500 VDC (60 sec.) TDR 3-1213SM 9 – 18 VDC 15 VDC 200 mA TDR 3-1222SM ± 12 VDC ± 125 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 approvals TDR 3-1223SM ± 15 VDC ± 100 mA Remote On/Off shutdown input for low input current (2.5 mA) TDR 3-2411SM 5 VDC 600 mA in standby operation TDR 3-2412SM 12 VDC 250 mA Casing over mold (UL 94 V-O rated) TDR 3-2413SM 18 – 36 VDC 15 VDC 200 mA TDR 3-2422SM ± 12 VDC ± 125 mA Full datasheet www.tracopower.com/products/tdr3sm.pdf TDR 3-2423SM ± 15 VDC ± 100 mA TDR 3-4811SM 5 VDC 600 mA Product with same electrical specifications available in TDR 3-4812SM 12 VDC 250 mA TDR 3-4813SM 36 – 75 VDC 15 VDC 200 mA DIP package. TDR 3-4822SM ± 12 VDC ± 125 mA See TDR-3 series page 51 TDR 3-4823SM ± 15 VDC ± 100 mA Dimensions Pin Single output Dual output 17.2 (0.68) 1 – Vin (GND) – Vin (GND) 8.4 (0.33) 12.8 (0.50) 2 Remote On/Off Remote On/Off 6 No con. Common 8 7 7 No con. – Vout 9 6 8 + Vout + Vout 9 – Vout Common 14 + Vin (Vcc) + Vin (Vcc) 2 14 1 () = Inches 22 1.8 2.54 10.16 2.54 (0.07) (0.1) (0.4) (0.1) 0.8 (0.03) 1.3 (0.05) top view 18.9 (0.74) www.tracopower.com SMD-Package DC/DC Converters TDR-3WISM Series 3 W UL 60950-1 Smallest 3 Watt converter in SMD package Ultra wide 4:1 input voltage range Operating temperature range –40 °C to +85 °C Fully regulated outputs Low ripple & noise 30 mVpk-pk No minimum load required I/O isolation 1500 VDC Short circuit protection Remote On/Off Available in tape & reel package Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation – Single output models: 1.0 % max. TDR 3-1211WISM 5 VDC 600 mA – Dual output models: 1.0 % max. TDR 3-1212WISM 12 VDC 250 mA Ripple & noise 30 mVp-p typ. (20 MHz BW) TDR 3-1213WISM 4.5 – 18 VDC 15 VDC 200 mA Short circuit protection continuous, automatic recovery TDR 3-1222WISM ± 12 VDC ± 125 mA Efficiency 81 % typ. TDR 3-1223WISM ± 15 VDC ± 100 mA Operating temperature –40 °C to +85 °C TDR 3-2411WISM 5 VDC 600 mA range above 70 °C derating 3.3%/K TDR 3-2412WISM 12 VDC 250 mA I/O isolation voltage 1500 VDC (60 sec.) TDR 3-2413WISM 9 – 36 VDC 15 VDC 200 mA TDR 3-2422WISM ± 12 VDC ± 125 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 approvals TDR 3-2423WISM ± 15 VDC ± 100 mA Remote On/Off shutdown input for low input current (2.5 mA) TDR 3-4811WISM 5 VDC 600 mA in standby operation TDR 3-4812WISM 12 VDC 250 mA Casing over mold (UL 94 V-O rated) TDR 3-4813WISM 18 – 75 VDC 15 VDC 200 mA TDR 3-4822WISM ± 12 VDC ± 125 mA Full datasheet www.tracopower.com/products/tdr3wi.pdf TDR 3-4823WISM ± 15 VDC ± 100 mA Product with same electrical specifications available in DIP package. See TDR-3WI series page 52 Dimensions Pin Single output Dual output 17.2 (0.68) 1 – Vin (GND) – Vin (GND) 8.4 (0.33) 12.8 (0.50) 2 Remote On/Off Remote On/Off 6 No con. Common 8 7 7 No con. – Vout 9 6 8 + Vout + Vout 9 – Vout Common 14 + Vin (Vcc) + Vin (Vcc) 2 14 1 () = Inches 23 1.8 2.54 10.16 2.54 (0.07) (0.1) (0.4) (0.1) 0.8 (0.03) 1.3 (0.05) top view 18.9 (0.74) www.tracopower.com DC/DC Converters SMD-Package CB CB THL-3WISM Series 3 W Schem Schemee UL 60950-1 Ultra wide 4:1 input voltage range Fully regulated outputs I/O isolation 1500 VDC Operating temperature range –40 °C to +80 °C Short circuit protection Input filter to meet EN 55022, class A Remote On/Off Available in tape & reel package Specifications Models Order code Input voltage Output voltage Output current Line regulation 1.0% max. max. Load regulation 1.2% max. THL 3-2410WISM 3.3 VDC 600 mA Ripple & noise <100 mVpk-pk (20 MHz BW) THL 3-2411WISM 5 VDC 600 mA Conducted EMI EN55022 class A THL 3-2412WISM 12 VDC 250 mA Short circuit protection continuous, automatic recovery THL 3-2413WISM 9 – 36 VDC 15 VDC 200 mA THL 3-2415WISM 24 VDC 125 mA Efficiency 80 % typ. THL 3-2421WISM ± 5 VDC ± 300 mA Operating temperature –40 °C to +80 °C range above 60 °C derating 2.5%/K THL 3-2422WISM ± 12 VDC ± 125 mA THL 3-2423WISM ± 15 VDC ± 100 mA I/O isolation voltage 1500 VDC (60 sec.) THL 3-4810WISM 3.3 VDC 600 mA Safety standards UL 60950-1, IEC/EN 60950-1, CB report THL 3-4811WISM 5 VDC 600 mA Remote On/Off shutdown input for low input current (5 mA) THL 3-4812WISM 12 VDC 250 mA in standby operation THL 3-4813WISM 18 – 75 VDC 15 VDC 200 mA Casing insert mold (UL 94 V-O rated plastic) THL 3-4815WISM 24 VDC 125 mA Full datasheet www.tracopower.com/products/thl3wism.pdf THL 3-4821WISM ± 5 VDC ± 300 mA THL 3-4822WISM ± 12 VDC ± 125 mA THL 3-4823WISM ± 15 VDC ± 100 mA Product with same electrical specifications available in DIP package. See THL-3WI series page 53 Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 2 Remote On/Off Remote On/Off 7 No con. No con. 8 No con. Common 9 + Vout + Vout 10 – Vout – Vout 16 + Vin (Vcc) + Vin (Vcc) 0.25 13.7 (0.54) (0.01) 8.0 (0.31) 18.1 (0.71) () = Inches 24 24.0 (0.94) 1.0 (0.04) 16 10 9 top view 17 2 8 3.11 2.54 12.70 (0.50) 2.54 (0.12) (0.10) (0.10) www.tracopower.com SMD-Package DC/DC Converters C CBB THL-6WISM Series 6 W Schem Schemee UL 60950-1 Ultra wide 4:1 input voltage range Fully regulated output Operating temperature range –40 °C to +80 °C I/O isolation 1500 VDC Short circuit protection Input filter to meet EN 55022, class A Remote On/Off Optional tape & reel package Specifications Models Order code Input voltage Output voltage Output current Line regulation 1.0 % max. max. Load regulation 1.2 % max. THL 6-2410WISM 3.3 VDC 1450 mA Ripple & Noise <100 mVpk-pk typ.(20 MHz BW) THL 6-2411WISM 5 VDC 1200 mA Input filter EN 55022, class EN55022 class A without external THL 6-2412WISM 12 VDC 500 mA components THL 6-2413WISM 9 – 36 VDC 15 VDC 400 mA Short circuit protection continuous, automatic recovery THL 6-2415WISM 24 VDC 250 mA Efficiency 83 % typ. THL 6-2421WISM ± 5 VDC ± 600 mA Operating temperature –40 °C to +80 °C THL 6-2422WISM ± 12 VDC ± 250 mA range above 60°C derating 2.5%/K THL 6-2423WISM ± 15 VDC ± 200 mA THL 6-4810WISM 3.3 VDC 1450 mA I/O isolation voltage 1500 VDC (60 sec.) THL 6-4811WISM 5 VDC 1200 mA Safety standards UL 60950-1, IEC/EN 60950-1, CB report THL 6-4812WISM 12 VDC 500 mA Remote On/Off shutdown input for low input current (10 mA) THL 6-4813WISM 18 – 75 VDC 15 VDC 400 mA in standby operation THL 6-4815WISM 24 VDC 250 mA Casing insert mold (UL 94 V-O rated plastic) THL 6-4821WISM ± 5 VDC ± 600 mA Full datasheet www.tracopower.com/products/thl6wism.pdf THL 6-4822WISM ± 12 VDC ± 250 mA THL 6-4823WISM ± 15 VDC ± 200 mA Dimensions Pin Single output Dual output 1 Remote On/Off Remote On/Off 2 – Vin (GND) – Vin (GND) 6 No con. Common 8 No con. – Vout 9 + Vout + Vout 11 – Vout Common 16 + Vin (Vcc) + Vin (Vcc) 0.15 20.3 (0.8) (0.01) 25.4 (1.0) 10.05 (0.4) () = Inches 25 22.0 (0.87) 1.5 (0.06) 16 11 9 top view 68 1 2 2.11 2.54 10.16 (0.40) 5.08 (0.08) (0.10) (0.20) www.tracopower.com DC/DC Converters SMD-Package CB TON-15 Series 15 W Scheme UL 60950-1 Low profile, open frame SMD or trough hole version Wide 2:1 input voltage range High efficiency up to 88 % I/O-isolation 2250 VDC (planar transformer) Operating temperature range –40 °C to +90 °C Remote On/Off Adjustable output voltage Specifications Specifications Models SMD Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation 0.2 % max. TON 15-2410SM 3.3 VDC 3500 mA Output voltage ±10 % by external resistor TON 15-2411SM 18 – 36 VDC 5 VDC 3000 mA adjustment TON 15-2412SM 12 VDC 1250 mA Ripple & noise <75 mVpk-pk TON 15-2413SM 15 VDC 1000 mA (20 MHz BW) <100 mVpk-pk for 12 & 15 VDC models TON 15-4810SM 3.3 VDC 3500 mA Conducted EMI EN55022, class EN55022 class A (internal filter) TON 15-4811SM 36 – 75 VDC 5 VDC 3000 mA Short circuit protection continuous, automatic recovery TON 15-4812SM 12 VDC 1250 mA Efficiency 86 % typ. TON 15-4813SM 15 VDC 1000 mA Operating temperature –40 °C to +85 °C range above 75 °C derating 3.3 %/K I/O isolation voltage 2250 VDC (60 sec.) basic insulation Trough Hole Models Safety standards / cUL/UL 60950-1, IEC 60950-1, CB-report approvals Order code Input voltage Output voltage Output current max. Remote On/Off shutdown input for low input current (2.5 mA) TON 15-2410 3.3 VDC 3500 mA in standby operation. TON 15-2411 18 – 36 VDC 5 VDC 3000 mA Negative remote function (forced On) on request. TON 15-2412 12 VDC 1250 mA Full datasheet www.tracopower.com/products/ton15.pdf TON 15-2413 15 VDC 1000 mA TON 15-4810 3.3 VDC 3500 mA TON 15-4811 36 – 75 VDC 5 VDC 3000 mA TON 15-4812 12 VDC 1250 mA TON 15-4813 15 VDC 1000 mA Dimensions Pin SMD version (SM) trough hole version 7.62 5.08 1 + Vin (Vcc) (0.3) (0.2) A-A 2 – Vin (GND) 6 2 1 3 + Vout 4 Trim 5 – Vout Bottom view 6 Remote On/Off 5 4 3 10.16 (0.4)10.16 (0.4) 8.5 8.5 5.2 (0.20) (0.335) (0.335) 23.88 (0.94) Section A-A 0.5max. (0.02) () = Inches 26 1.3max. (0.05) 0.8 (0.031) 20.32 (0.80) 3.81 (0.15) 27.94 (1.10) www.tracopower.com SMD-Package DC/DC Converters CB Scheme TON-15WI Series 15 W UL 60950-1 Low profile, open frame SMD or trough hole version Ultra wide 4:1 input voltage range High efficiency up to 88 % I/O-isolation 2250 VDC (planar transformer) Operating temperature range –40 °C to +85 °C Remote On/Off Adjustable output voltage Specifications Specifications Models SMD Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation 0.2 % max. TON 15-2410WISM 3.3 VDC 4000 mA Output voltage ±10 % by external resistor TON 15-2411WISM 9 – 36 VDC 5 VDC 3000 mA adjustment TON 15-2412WISM 12 VDC 1300 mA Ripple & noise <75 mVpk-pk TON 15-2413WISM 15 VDC 1000 mA (20 MHz BW) <100 mVpk-pk for 12 & 15 VDC models TON 15-4810WISM 3.3 VDC 4000 mA Conducted EMI EN55022, class EN55022 class A (with external capacitors) TON 15-4811WISM 18 – 75 VDC 5 VDC 3000 mA Short circuit protection continuous, automatic recovery TON 15-4812WISM 12 VDC 1300 mA Efficiency 86 % typ. TON 15-4813WISM 15 VDC 1000 mA Operating temperature –40 °C to +85 °C range above 60 °C derating 2.0 %/K Trough Hole Models I/O isolation voltage 2250 VDC (60 sec.) basic insulation Safety standards / cUL/UL 60950-1, IEC 60950-1, CB-report Order code Input voltage Output voltage Output current approvals max. Remote On/Off shutdown input for low input current (2.5 mA) TON 15-2410WI 3.3 VDC 4000 mA in standby operation. TON 15-2411WI 9 – 36 VDC 5 VDC 3000 mA Negative remote function (forced On) on request. TON 15-2412WI 12 VDC 1300 mA Full datasheet www.tracopower.com/products/ton15wi.pdf TON 15-2413WI 15 VDC 1000 mA TON 15-4810WI 3.3 VDC 4000 mA TON 15-4811WI 18 – 75 VDC 5 VDC 3000 mA TON 15-4812WI 12 VDC 1300 mA TON 15-4813WI 15 VDC 1000 mA Dimensions Pin SMD version (SM) trough hole version 7.62 5.08 1 + Vin (Vcc) (0.3) (0.2) A-A 2 – Vin (GND) 6 2 1 3 + Vout 4 Trim 5 – Vout Bottom view 6 Remote On/Off 5 4 3 10.16 (0.4)10.16 (0.4) 8.5 8.5 5.2 (0.20) (0.335) (0.335) 23.88 (0.94) Section A-A 0.5max. (0.02) () = Inches 27 1.3max. (0.05) 0.8 (0.031) 3.81 20.32 (0.80) (0.15) 27.94 (1.10) www.tracopower.com DC/DC Converters SIP-Package TMA / TME Series 1 W Industry standard pinout Non-regulated output Single and dual output models I/O isolation voltage 1000 VDC High efficiency Operating temperature range –40 °C to +85 °C Specifications Models Input voltage Output Output Order code Line regulation non regulated voltage current max. TME 0303S 3.3 VDC ± 10 % 3.3 VDC 260 mA Load regulation 10% max. TME 0305S 5 VDC 200 mA Ripple & Noise – TMA <75 mVpk-pk (20 MHz BW) TME 0503S 3.3 VDC 260 mA – TME <150 mVpk-pk (20 MHz BW) TMA 0505S TME 0505S 5 VDC 200 mA Short circuit protection limited 1 sec. TME 0509S 9 VDC 110 mA Efficiency 80 % typ. TMA 0512S TME 0512S 12 VDC 80 mA Operating temperature –40 °C to +85 °C (no derating) 5 VDC ± 10 % TMA 0515S TME 0515S 15 VDC 65 mA range TMA 0505D ± 5 VDC ± 100 mA I/O isolation voltage 1000 VDC (60 sec.) TMA 0512D ± 12 VDC ± 40 mA TMA 0515D ± 15 VDC ± 35 mA Casing plastic (UL 94 V-O rated) TMA 1205S TME 1205S 5 VDC 200 mA Full datasheet www.tracopower.com/products/tme.pdf TME 1209S 9 VDC 110 mA www.tracopower.com/products/tma.pdf TMA 1212S TME 1212S 12 VDC 80 mA TMA 1215S TME 1215S 12 VDC ± 10 % 15 VDC 65 mA For improved load regulation TMA 1205D ± 5 VDC ± 100 mA see TRA-1 series page 29 TMA 1212D ± 12 VDC ± 40 mA TMA 1215D ± 15 VDC ± 35 mA TMA 1505S 5 VDC 200 mA TMA 1512S 12 VDC 80 mA TMA 1515S 15 VDC ± 10 % 15 VDC 65 mA TMA 1505D ± 5 VDC ± 100 mA TMA 1512D ± 12 VDC ± 40 mA TMA 1515D ± 15 VDC ± 35 mA TMA 2405S TME 2405S 5 VDC 200 mA TME 2409S 9 VDC 110 mA TMA 2412S TME 2412S 12 VDC 80 mA TMA 2415S TME 2415S 24 VDC ± 10 % 15 VDC 65 mA TMA 2405D ± 5 VDC ± 100 mA TMA 2412D ± 12 VDC ± 40 mA TMA 2415D ± 15 VDC ± 35 mA Dimensions TMA TMA TME Pin TME TMA Single output Dual output Single output 1 + Vin (Vcc) + Vin (Vcc) – Vin (GND) 2 – Vin (GND) – Vin (GND) + Vin (Vcc) 3 No Pin No Pin – Vout 4 – Vout – Vout + Vout 5 No Pin Common 0.5 0.5 6 + Vout + Vout (0.02) (0.02) 3 x 2.54 2.3 2.54 5.08 2.54 2.54 1.9 (3 x 0.1) (0.09) (0.1) (0.2) (0.1) (0.1) (0.08) (0.45) 19.5 (0.77) 11.5 Bo ttom v ie w 1 2 3 4 Bo ttom v ie w 1 2 4 5 6 0.5 (0.02) 0.5 (0.02) () = Inches 28 0.25 (0.01) 3.2 (0.02) 0.5 1.8 (0.13) (0.07) 10.2 (0.4) 6.1 (0.24) 7.1 (0.28) 24 Vin Mo de ls 0.25(0 .01) 1.05 (0.04) 3.2 0.5 (0.02) (0.13) 10.2 (0.4) 6.1 (0.24) 7.1 (0.28) 24/15 Vin Mo de ls www.tracopower.com SIP-Package DC/DC Converters CB CB TRA-1 Series 1 W Schem Schemee UL 60950-1 Semi-regulated output (load) Industry standard pinout Very high efficiency up to 88% Single and dual output models I/O isolation voltage 1000 VDC Operating temperature range –40 °C to +85 °C Specifications Models Order code Input voltage Output voltage Output current Line regulation non regulated max. Load regulation 5% typ for 5V input models TRA 1-0511 5 VDC 200 mA (20- 100% load) 3.5% typ for 12V input models TRA 1-0519 9 VDC 110 mA 2.5% typ for 24V input models TRA 1-0512 12 VDC 84 mA Ripple & Noise <60 mVp-p (20 MHz BW) TRA 1-0513 5 VDC ± 10 % 15 VDC 67 mA Short circuit protection limited 0.5 sec. TRA 1-0521 ± 5 VDC ± 100 mA Efficiency 86 % typ. TRA 1-0522 ± 12 VDC ± 42 mA Operating temperature –40 °C to +85 °C (no derating) TRA 1-0523 ± 15 VDC ± 34 mA range TRA 1-1211 5 VDC 200 mA I/O isolation voltage 1000 VDC (60 sec.) TRA 1-1219 9 VDC 110 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 CB-report TRA 1-1212 12 VDC 84 mA approvals TRA 1-1213 12 VDC ± 10 % 15 VDC 67 mA Casing plastic (UL 94 V-O rated) TRA 1-1221 ± 5 VDC ± 100 mA Full datasheet www.tracopower.com/products/tra1.pdf TRA 1-1222 ± 12 VDC ± 42 mA TRA 1-1223 ± 15 VDC ± 34 mA TRA 1-2411 5 VDC 200 mA TRA 1-2419 9 VDC 110 mA TRA 1-2412 12 VDC 84 mA TRA 1-2413 24 VDC ± 10 % 15 VDC 67 mA TRA 1-2421 ± 5 VDC ± 100 mA TRA 1-2422 ± 12 VDC ± 42 mA TRA 1-2423 ± 15 VDC ± 34 mA Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 2 – Vin (GND) – Vin (GND) 4 – Vout – Vout 5 No pin Common 6 + Vout + Vout 0.5 (0.02) 2.3 ±0.4 2.54 2.54 2.54 5.08 0.5 (0.02) (0.1) (0.2) (0.09 (0.1) (0.1) ±0.02) 19.5 (0.77) Bottom view 1 2 4 5 6 0.5 (0.02) () = Inches 29 0.25 (0.01) 0.5 (0.02) 1.3 3.2 (0.13) 10.2 (0.4) (0.05) 6.1 (0.24) 7.1 (0.28) 24 V Models www.tracopower.com DC/DC Converters SIP-Package TMV Series 1 W Industry standard pinout Single and dual output models I/O isolation voltage 3000 VDC Operating temperature range –40 °C to +85 °C Specifications Models Order code Input voltage Output voltage Output current Line regulation non regulated max. Load regulation 10% max. TMV 0505S 5 VDC 200 mA Ripple & noise <100 mVpk-pk (20 MHz BW) TMV 0509S 9 VDC 110 mA Short circuit protection limited 0.5 sec. TMV 0512S 12 VDC 80 mA Efficiency 77 % typ. TMV 0515S 5 VDC ± 10 % 15 VDC 65 mA TMV 0505D ± 5 VDC ± 100 mA Operating temperature –40 °C to +85 °C range above 80 °C derating 4%/K TMV 0512D ± 12 VDC ± 40 mA I/O isolation voltage 3000 VDC (60 sec.) functional insulation TMV 0515D ± 15 VDC ± 30 mA TMV 1205S 5 VDC 200 mA I/O isolation capacitance 60 pF typ. TMV 1212S 12 VDC 80 mA I/O isolation resistance >10 GOhm TMV 1215S 12 VDC ± 10 % 15 VDC 65 mA Casing plastic (UL 94 V-O rated) TMV 1205D ± 5 VDC ± 100 mA Full datasheet www.tracopower.com/products/tmv.pdf TMV 1212D ± 12 VDC ± 40 mA TMV 1215D ± 15 VDC ± 30 mA TMV 2405S 5 VDC 200 mA TMV 2412S 12 VDC 80 mA Product available with reinforced insulation TMV 2415S 24 VDC ± 10 % 15 VDC 65 mA See TMV-EN series page 111 TMV 2405D ± 5 VDC ± 100 mA TMV 2412D ± 12 VDC ± 40 mA For improved load regulation TMV 2415D ± 15 VDC ± 30 mA see TRV-1 series page 32 Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 2 – Vin (GND) – Vin (GND) 5 – Vout – Vout 6 No pin Common 7 + Vout + Vout 0.5 (0.02) 2.32.54 7.62 2.54 2.54 (0.09) (0.1)( (0.3) 0.1) (0.1) 19.5 (0.77) Bottom view 1 2 5 6 7 0.5 (0.02) () = Inches 30 0.25 (0.01) 1.25 (0.05) 3.5 0.5 (0.02) (0.14) 10.2 (0.4) 6.1 (0.24) 7.1 (0.28) 24 Vin Models www.tracopower.com SIP-Package DC/DC Converters C CBB TMV-HI Series 1 W UL 60950-1 Schem Schemee UL 60601-1 Industy standard pinout Very high 5200 VDC I/O-isolation Low coupling capacitance 7pF Suitable for IGBT applications Operating temperature range –40 °C to +85 °C without derating Specifications Models Order code Input voltage Output voltage Output current Line regulation 1.2 % max. Load regulation 5.0 VDC models: 15 % max. TMV 0503SHI 3.3 VDC 303 mA 3.3 VDC models 20% max. TMV 0505SHI 5.0 VDC 200 mA other models: 10% max. TMV 0509SHI 9.0 VDC 111 mA Ripple & noise <100 mVpk-pk (20 MHz BW) TMV 0512SHI 12 VDC 84 mA Efficiency 76 % typ. TMV 0515SHI 5 VDC ± 10 % 15 VDC 66 mA Operating temperature –40 °C to +85 °C (without derating) TMV 0505DHI ± 5.0 VDC ±100 mA range TMV 0509DHI ± 9.0 VDC ± 56 mA TMV 0512DHI ± 12 VDC ± 42 mA I/O isolation voltage 5200 VDC (60 sec.) TMV 0515DHI ± 15 VDC ± 33 mA I/O isolation dV/dt 15kV/µs @ 100kHz max. TMV 05159HI ± 15 / –9 VDC ± 33 / –55 mA I/O isolation capacitance 7 pF typ. TMV 1203SHI 3.3 VDC 303 mA I/O isolation resistance >10 GOhm TMV 1205SHI 5.0 VDC 200 mA Casing plastic (UL 94 V-O rated) TMV 1209SHI 9.0 VDC 111 mA Full datasheet www.tracopower.com/products/tmv-hi.pdf TMV 1212SHI 12 VDC 84 mA TMV 1215SHI 12 VDC ± 10 % 15 VDC 66 mA TMV 1205DHI ± 5.0 VDC ±100 mA TMV 1209DHI ± 9.0 VDC ± 56 mA TMV 1212DHI ± 12 VDC ± 42 mA TMV 1215DHI ± 15 VDC ± 33 mA TMV 12159HI ± 15 / –9 VDC ± 33 / –55 mA TMV 1503SHI 3.3 VDC 303 mA TMV 1505SHI 5.0 VDC 200 mA TMV 1509SHI 9.0 VDC 111 mA TMV 1512SHI 12 VDC 84 mA TMV 1515SHI 15 VDC ± 10 % 15 VDC 66 mA TMV 1505DHI ± 5.0 VDC ±100 mA TMV 1509DHI ± 9.0 VDC ± 56 mA TMV 1512DHI ± 12 VDC ± 42 mA TMV 1515DHI ± 15 VDC ± 33 mA TMV 15159HI ± 15 / –9 VDC ± 33 / –55 mA Dimensions Dimensions TMV 2403SHI 3.3 VDC 303 mA TMV 2405SHI 5.0 VDC 200 mA TMV 2409SHI 9.0 VDC 111 mA TMV 2412SHI 12 VDC 84 mA TMV 2415SHI 24 VDC ± 10 % 15 VDC 66 mA TMV 2405DHI ± 5.0 VDC ±100 mA 0.5 TMV 2409DHI ± 9.0 VDC ± 56 mA (0.02) TMV 2412DHI ± 12 VDC ± 42 mA 2.3 2.54 2.54 2.54 ±0.4 0.5 (0.02) 7.62 (0.3) TMV 2415DHI ± 15 VDC ± 33 mA (0.09 (0.1) (0.1) (0.1) ±0.02) TMV 24159HI ± 15 / –9 VDC ± 33 / –55 mA 19.5 (0.77) Pin Single output Dual output Bottom view 1 + Vin (Vcc) + Vin (Vcc) 1 2 5 6 7 2 – Vin (GND) – Vin (GND) 5 – Vout – Vout 0.5 (0.02) 6 No pin Common 7 + Vout + Vout () = Inches 31 NEW Product (0.01) 0.25 0.5 (0.02) 2.0 (0.05) 3.2 (0.13) 10.2 (0.4) 7.1 (0.28) www.tracopower.com DC/DC Converters SIP-Package CB CB TRV-1 Series 1 W Schem Schemee UL 60950-1 Semi-regulated output (load) Industry standard pinout Very high efficiency up to 88% I/O isolation voltage 3000 VDC Operating temperature range –40 °C to +85 °C Specifications Models Order code Input voltage Output voltage Output current Line regulation non regulated max. Load regulation 5% typ for 5V input models TRV 1-0511 5 VDC 200 mA (20- 100% load) 3.5% typ for 12 V & 24 V input models TRV 1-0519 5 VDC ± 10 % 9 VDC 110 mA Ripple & Noise <50 mVp-p (20 MHz BW) TRV 1-0512 12 VDC 84 mA Short circuit protection limited 0.5 sec. TRV 1-0513 15 VDC 67 mA Efficiency 86 % typ. TRV 1-1211 5 VDC 200 mA Operating temperature –40 °C to +85 °C (no derating) TRV 1-1219 12 VDC ± 10 % 9 VDC 110 mA range TRV 1-1212 12 VDC 84 mA I/O isolation voltage 3000 VDC (60 sec.) functional insulation TRV 1-1213 15 VDC 67 mA TRV 1-2411 5 VDC 200 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 CB-report approvals TRV 1-2419 24 VDC ± 10 % 9 VDC 110 mA Casing plastic (UL 94 V-O rated) TRV 1-2412 12 VDC 84 mA TRV 1-2413 15 VDC 67 mA Full datasheet www.tracopower.com/products/trv1.pdf Dimensions Pin 1 + Vin (Vcc) 2 – Vin (GND) 5 – Vout 7 + Vout 0.5 (0.02) 2.35 2.54 7.62 5.08 (0.3) (0.09) (0.1) (0.2) 0.5 (0.02) 19.5 (0.77) Bottom view 1 2 5 7 0.5 (0.02) () = Inches 32 0.25 (0.01) 0.5 (0.02) 1.3 3.2 (0.13) 10.2 (0.4) (0.05) 6.1 (0.24) 7.1 (0.28) 24 V Models www.tracopower.com SIP-Package DC/DC Converters TMR-1 Series 1 W Fully regulated outputs Wide 2 : 1 input voltage range Operating temperature range –40°C to +85°C without derating No minimum load required I/O isolation voltage 1500 VDC Short circuit protection Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation 1 % max. TMR 1-0511 5 VDC 200 mA Ripple & noise <110mVpk-pk (20 MHz BW) TMR 1-0512 12 VDC 83 mA Short circuit protection continuous, automatic recovery TMR 1-0513 4.5 - 9.0 VDC 15 VDC 67 mA Efficiency 78 % typ. TMR 1-0522 ± 12 VDC ±42 mA TMR 1-0523 ± 15 VDC ± 33 mA Operating temperature –40 °C to +85 °C (without derating) range TMR 1-1211 5 VDC 200 mA I/O isolation voltage 1500 VDC (60 sec.) TMR 1-1212 12 VDC 83 mA TMR 1-1213 9 - 18 VDC 15 VDC 67 mA Casing plastic (UL 94-0 rated) TMR 1-1222 ± 12 VDC ±42 mA Full datasheet www.tracopower.com/products/tmr1.pdf TMR 1-1223 ± 15 VDC ± 33 mA TMR 1-2411 5 VDC 200 mA TMR 1-2412 12 VDC 83 mA TMR 1-2413 18 - 36 VDC 15 VDC 67 mA TMR 1-2422 ± 12 VDC ± 42 mA TMR 1-2423 ± 15 VDC ± 33 mA TMR 1-4811 5 VDC 200 mA TMR 1-4812 12 VDC 83 mA TMR 1-4813 36 - 75 VDC 15 VDC 67 mA TMR 1-4822 ± 12 VDC ± 42 mA TMR 1-4823 ± 15 VDC ± 33 mA Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 2 + Vin (Vcc) + Vin (Vcc) 4 + Vout + Vout 5 No pin Common 6 – Vout – Vout 0.5 (0.02) 2.3 ±0.4 2.54 2.54 2.54 5.08 0.5 (0.02) (0.1) (0.2) (0.09 (0.1) (0.1) ±0.02) 17.0 (0.67) Bottom view 1 2 4 5 6 0.5 (0.02) () = Inches 33 NEW Product 0.25 (0.01) 0.5 (0.02) 3.2 (0.13) 2.5 11.0 (0.4) (0.10) 7.62 (0.30) www.tracopower.com DC/DC Converters SIP-Package TMH Series 2 W Industry standard pinout Single and dual output models Operating temperature range –40 °C to +85 °C Specifications Models Order code Input voltage Output voltage Output current Line regulation non regulated max. Load regulation 10% max. TMH 0505S 5 VDC 400 mA Ripple & noise < 75 mVpk-pk for 5 Vin models TMH 0512S 12 VDC 165 mA (20 MHz BW) <150 mVpk-pk for 12/24 Vin models TMH 0515S 5 VDC ± 10 % 15 VDC 130 mA Short circuit protection limited 0.5 sec. max. TMH 0505D ± 5 VDC ± 200 mA Efficiency 81 % typ. TMH 0512D ± 12 VDC ± 80 mA Operating temperature –40 °C to +85 °C TMH 0515D ± 15 VDC ± 65 mA range above 70°C derating 3 %/K TMH 1205S 5 VDC 400 mA I/O isolation voltage 1000 VDC (60 sec.) TMH 1212S 12 VDC 165 mA TMH 1215S 12 VDC ± 10 % 15 VDC 130 mA Casing plastic (UL 94 V-O rated) TMH 1205D ± 5 VDC ± 200 mA Full datasheet www.tracopower.com/products/tmh.pdf TMH 1212D ± 12 VDC ± 80 mA TMH 1215D ± 15 VDC ± 65 mA TMH 2405S 5 VDC 400 mA TMH 2412S 12 VDC 165 mA For improved load regulation TMH 2415S 24 VDC ± 10 % 15 VDC 130 mA TMH 2405D ± 5 VDC ± 200 mA see TRA-3 series page 35 TMH 2412D ± 12 VDC ± 80 mA TMH 2415D ± 15 VDC ± 65 mA Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 2 – Vin (GND) – Vin (GND) 4 – Vout – Vout 5 No pin Common 6 + Vout + Vout 0.5 (0.02) 2.3 2.54 5.08 2.54 2.54 (0.09) (0.1)( (0.2) 0.1) (0.1) 19.5 (0.77) Bottom view 1 2 4 5 6 0.5 (0.02) () = Inches 34 0.25 (0.01) 1.25 (0.05) 0.5 (0.02) 3.2 (0.13) 7.5 (0.30) 10.2 (0.4) www.tracopower.com SIP-Package DC/DC Converters CB CB TRA-3 Series 3 W Schem Schemee UL 60950-1 Semi-regulated output (load) Very high efficiency up to 89% Operating temperature range –40 °C to +85 °C Specifications Models Order code Input voltage Output voltage Output current Line regulation non regulated max. Load regulation 7% typ for 5V input models TRA 3-0511 5 VDC 600 mA (20- 100% load) 5% typ for 12V & 24V input models TRA 3-0519 5 VDC ± 10 % 9 VDC 333 mA Ripple & Noise 60 mVp-p typ. (20 MHz BW) TRA 3-0512 12 VDC 250 mA Short circuit protection limited 0.5 sec. TRA 3-0513 15 VDC 200 mA Efficiency 86 % typ. TRA 3-1211 5 VDC 600 mA Operating temperature –40 °C to +85 °C (no derating) TRA 3-1219 12 VDC ± 10 % 9 VDC 333 mA range TRA 3-1212 12 VDC 250 mA I/O isolation voltage 1000 VDC (60 sec.) TRA 3-1213 15 VDC 200 mA TRA 3-2411 5 VDC 600 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, reports pending approvals TRA 3-2419 24 VDC ± 10 % 9 VDC 333 mA Casing plastic (UL 94 V-O rated) TRA 3-2412 12 VDC 250 mA TRA 3-2413 15 VDC 200 mA Full datasheet www.tracopower.com/products/tra3.pdf Dimensions Pin 1 + Vin (Vcc) 2 – Vin (GND) 4 – Vout 5 No pin 0.5 6 + Vout (0.02) 2.3 ±0.4 2.54 2.54 2.54 5.08 0.5 (0.02) (0.09 (0.1) (0.2) (0.1) (0.1) ±0.02) 19.5 (0.77) Bottom view 1 2 4 5 6 0.5 (0.02) () = Inches 35 0.25 (0.01) 0.5 (0.02) 3.2 (0.13) 1.3 10.2 (0.4) (0.05) 7.6 (0.30) www.tracopower.com DC/DC Converters SIP-Package TMR-2E Series 2 W Wide 2:1 input range Fully regulated outputs High quality/cost performance Short circuit protection Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation 0.75 % max. (25 - 100% load) TMR 2-0510E 3.3 VDC 500 mA Ripple & noise <50 mVpk-pk (20 MHz BW) TMR 2-0511E 4.5 – 9.0 VDC 5 VDC 400 mA (no external output capacitor required) TMR 2-0512E 12 VDC 167 mA Short circuit protection continuous, automatic recovery TMR 2-1210E 3.3 VDC 500 mA Efficiency 78 % typ. TMR 2-1211E 9 – 18 VDC 5 VDC 400 mA 5 VDC input models: 73 % typ. TMR 2-1212E 12 VDC 167 mA Operating temperature –40 °C to +85 °C TMR 2-2410E 3.3 VDC 500 mA range above 65 °C derating 2.8 %/K TMR 2-2411E 18 – 36 VDC 5 VDC 400 mA I/O isolation voltage 1000 VDC (60 sec.) TMR 2-2412E 12 VDC 167 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 (no report) TMR 2-4810E 3.3 VDC 500 mA Remote On/Off shutdown input for low input current (1 mA) TMR 2-4811E 36 – 75 VDC 5 VDC 400 mA in standby operation TMR 2-4812E 12 VDC 167 mA Casing plastic (UL 94 V-O rated) Full datasheet www.tracopower.com/products/tmr2e.pdf Dimensions Pin Single output 1 – Vin (GND) 2 + Vin (Vcc) 3 Remote On/Off 5 No con. 6 + Vout 7 – Vout 2.0 2.54 2.54 5.08 2.54 2.54 2.54 8 No con. (0.08) (0.1) (0.1) (0.2) (0.1) (0.1) (0.1) 21.8 (0.86) Bottom view 12 35 67 8 0.5 (0.02) () = Inches 36 0.5 (0.02) 0.25 (0.01) 3.2 11.2 (0.44) 2.7 (0.13) (0.11) (0.37) 9.3 www.tracopower.com SIP-Package DC/DC Converters TMR-2 Series 2 W UL 60950-1 Wide 2:1 input range Fully regulated outputs Single and dual output models Operating temperature range –40 °C to +85 °C without derating Low ripple and noise <50 mVpk-pk Short circuit protection Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation 1.0 % max. TMR 0510 3.3 VDC 500 mA Ripple & noise <50 mVpk-pk (20 MHz BW) TMR 0511 5 VDC 400 mA (no external output capacitor required) TMR 0512 4.5 – 9.0 VDC 12 VDC 165 mA Short circuit protection continuous, automatic recovery TMR 0521 ± 5 VDC ± 200 mA Efficiency 82 % typ. TMR 0522 ± 12 VDC ± 85 mA 5 VDC input models: 80 % typ. TMR 0523 ± 15 VDC ± 65 mA Operating temperature –40 °C to +85 °C TMR 1210 3.3 VDC 500 mA range above 75°C derating 2 %/K TMR 1211 5 VDC 400 mA I/O isolation voltage 1000 VDC (60 sec.) TMR 1212 9 – 18 VDC 12 VDC 165 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 TMR 1221 ± 5 VDC ± 200 mA approvals TMR 1222 ± 12 VDC ± 85 mA Remote On/Off shutdown input for low input current (1 mA) TMR 1223 ± 15 VDC ± 65 mA in standby operation TMR 2410 3.3 VDC 500 mA Casing plastic (UL 94 V-O rated) TMR 2411 5 VDC 400 mA Full datasheet www.tracopower.com/products/tmr.pdf TMR 2412 18 – 36 VDC 12 VDC 165 mA TMR 2421 ± 5 VDC ± 200 mA TMR 2422 ± 12 VDC ± 85 mA TMR 2423 ± 15 VDC ± 65 mA TMR 4810 3.3 VDC 500 mA TMR 4811 5 VDC 400 mA TMR 4812 36 – 75 VDC 12 VDC 165 mA TMR 4821 ± 5 VDC ± 200 mA TMR 4822 ± 12 VDC ± 85 mA TMR 4823 ± 15 VDC ± 65 mA Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 2 + Vin (Vcc) + Vin (Vcc) 3 Remote On/Off Remote On/Off 5 No con. No con. 6 + Vout + Vout 7 – Vout Common 2.0 2 x 2.54 5.08 3 x 2.54 8 No con. – Vout (0.08) (2 x 0.1) (0.2) (3 x 0.1) 21.8 (0.86) Bottom view 12 35 67 8 0.5 (0.02) () = Inches 37 0.5 (0.02) 0.25 (0.01) 4.0 11.1 (0.44) 3.2 (0.16) (0.13) 9.2 (0.36) www.tracopower.com DC/DC Converters SIP-Package TMR-2WIN Series 2 W Miniature SIP package Wide 4:1 input range Fully regulated outputs I/O-isolation 1500 VDC Operating temperature range –40 °C to +90 °C Low ripple and noise No minimum load required Short circuit protection Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation 1.0 % max. TMR 2-1210WIN 3.3 VDC 500 mA Ripple & noise <100 mVpk-pk (20 MHz BW) TMR 2-1211WIN 5 VDC 400 mA Short circuit protection continuous, automatic recovery TMR 2-1212WIN 12 VDC 167 mA Efficiency 80 % typ. TMR 2-1213WIN 4.5 – 18 VDC 15 VDC 134 mA TMR 2-1221WIN ± 5 VDC ± 200 mA Operating temperature –40 °C to +90 °C TMR 2-1222WIN ± 12 VDC ± 83 mA range above 75 °C derating 3.3 %/K TMR 2-1223WIN ± 15 VDC ± 67 mA I/O isolation voltage 1500 VDC (60 sec.) TMR 2-2410WIN 3.3 VDC 500 mA Safety standards UL 60950-1, IEC/EN 60950-1 (no report) TMR 2-2411WIN 5 VDC 400 mA Remote On/Off shutdown input for low input current (3mA) TMR 2-2412WIN 12 VDC 167 mA in standby operation TMR 2-2413WIN 9 – 36 VDC 15 VDC 134 mA Casing plastic (UL 94 V-O rated) TMR 2-2421WIN ± 5 VDC ± 200 mA Full datasheet www.tracopower.com/products/tmr2win.pdf TMR 2-2422WIN ± 12 VDC ± 83 mA TMR 2-2423WIN ± 15 VDC ± 67 mA TMR 2-4810WIN 3.3 VDC 500 mA TMR 2-4811WIN 5 VDC 400 mA TMR 2-4812WIN 12 VDC 167 mA TMR 2-4813WIN 18 – 75 VDC 15 VDC 134 mA TMR 2-4821WIN ± 5 VDC ± 200 mA TMR 2-4822WIN ± 12 VDC ± 83 mA TMR 2-4823WIN ± 15 VDC ± 67 mA Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 2 + Vin (Vcc) + Vin (Vcc) 3 Remote On/Off Remote On/Off 5 No con. No con. 6 + Vout + Vout 7 – Vout Common 8 No con. – Vout 2.0 2 x 2.54 5.08 3 x 2.54 (0.08) (2 x 0.1) (0.2) (3 x 0.1) 21.8 (0.86) bottom view 12 35 67 8 0.5 (0.02) () = Inches 38 NEW Product 0.5 (0.02) 0.25 (0.01) 3.2 11.2 (0.44) 2.5 (0.13) (0.10) 9.3 (0.37) www.tracopower.com SIP-Package DC/DC Converters CB CB TMR-3E Series 3 W Schem Schemee UL 60950-1 Wide 2:1 input range Fully regulated outputs Single and dual output models High quality/cost performance I/O-isolation 1500 VDC Short circuit protection Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation 1.0 % max. TMR 3-0510E 3.3 VDC 700 mA Ripple & noise <75 mVpk-pk (20 MHz BW) TMR 3-0511E 5 VDC 600 mA Short circuit protection continuous, automatic recovery TMR 3-0512E 12 VDC 250 mA Efficiency 81 % typ. TMR 3-0513E 4.5 – 9 VDC 15 VDC 200 mA 5 VDC input models: 76 % typ. TMR 3-0521E ± 5 VDC ± 300 mA TMR 3-0522E ± 12 VDC ± 125 mA Operating temperature –40 °C to +85 °C range above 70 °C derating 3.3 %/K TMR 3-0523E ± 15 VDC ± 100 mA TMR 3-1210E 3.3 VDC 700 mA I/O isolation voltage 1500 VDC (60 sec.) TMR 3-1211E 5 VDC 600 mA Safety standards UL 60950-1, IEC/EN 60950-1, CB report TMR 3-1212E 12 VDC 250 mA Remote On/Off shutdown input for low input current (1 mA) TMR 3-1213E 9 – 18 VDC 15 VDC 200 mA in standby operation TMR 3-1221E ± 5 VDC ± 300 mA Casing plastic (UL 94 V-O rated) TMR 3-1222E ± 12 VDC ± 125 mA Full datasheet www.tracopower.com/products/tmr3e.pdf TMR 3-1223E ± 15 VDC ± 100 mA TMR 3-2410E 3.3 VDC 700 mA TMR 3-2411E 5 VDC 600 mA TMR 3-2412E 12 VDC 250 mA TMR 3-2413E 18 – 36 VDC 15 VDC 200 mA TMR 3-2421E ± 5 VDC ± 300 mA TMR 3-2422E ± 12 VDC ± 125 mA TMR 3-2423E ± 15 VDC ± 100 mA TMR 3-4810E 3.3 VDC 700 mA TMR 3-4811E 5 VDC 600 mA TMR 3-4812E 12 VDC 250 mA TMR 3-4813E 36 – 75 VDC 15 VDC 200 mA TMR 3-4821E ± 5 VDC ± 300 mA TMR 3-4822E ± 12 VDC ± 125 mA TMR 3-4823E ± 15 VDC ± 100 mA Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 2 + Vin (Vcc) + Vin (Vcc) 3 Remote On/Off Remote On/Off 5 No con. No con. 6 + Vout + Vout 2.0 (0.08) 2 x 2.54 5.08 3 x 2.54 7 – Vout Common (2 x 0.1)( (0.2) 3 x 0.1) 8 No con. – Vout Bottom view 0.5 (0.02) 12 36 5 78 0.5 20.8 (0.82) (0.02) 21.8 (0.86) () = Inches 39 0.25 0.5 (0.02) (0.01) 2.7 3.2 11.2 (0.44) (0.11) (0.13) 9.3 (0.37) www.tracopower.com DC/DC Converters SIP-Package TMR-3 Series 3 W UL 60950-1 Wide 2:1 input range Fully regulated outputs I/O isolation 1500 VDC No minimum load required Short circuit protection Remote On/Off Specifications Models Order code * Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation – Single output models: 0.5 % max. TMR 3-0510 3.3 VDC 700 mA – Dual output models: 1.0 % max. TMR 3-0511 5 VDC 600 mA Ripple & noise <50 mVpk-pk (20 MHz BW) TMR 3-0512 12 VDC 250 mA no external output capacitor required TMR 3-0513 4.5 – 9.0 VDC 15 VDC 200 mA Short circuit protection continuous, automatic recovery TMR 3-0521 ± 5 VDC ± 300 mA Efficiency 79 % typ. TMR 3-0522 ± 12 VDC ± 125 mA Operating temperature –40 °C to +85 °C TMR 3-0523 ± 15 VDC ± 100 mA range above 70 °C derating 3.3 %/K TMR 3-1210 3.3 VDC 700 mA TMR 3-1211 5 VDC 600 mA I/O isolation voltage 1500 VDC (60 sec.) TMR 3-1212 12 VDC 250 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 approvals TMR 3-1213 9 – 18 VDC 15 VDC 200 mA TMR 3-1221 ± 5 VDC ± 300 mA Remote On/Off shutdown input for low input current (2.5 mA) TMR 3-1222 ± 12 VDC ± 125 mA in standby operation TMR 3-1223 ± 15 VDC ± 100 mA Casing plastic (UL 94 V-O rated) TMR 3-2410 3.3 VDC 700 mA Full datasheet www.tracopower.com/products/tmr3.pdf TMR 3-2411 5 VDC 600 mA TMR 3-2412 12 VDC 250 mA TMR 3-2413 18 – 36 VDC 15 VDC 200 mA TMR 3-2421 ± 5 VDC ± 300 mA TMR 3-2422 ± 12 VDC ± 125 mA TMR 3-2423 ± 15 VDC ± 100 mA TMR 3-4810 3.3 VDC 700 mA TMR 3-4811 5 VDC 600 mA TMR 3-4812 12 VDC 250 mA TMR 3-4813 36 – 75 VDC 15 VDC 200 mA TMR 3-4821 ± 5 VDC ± 300 mA TMR 3-4822 ± 12 VDC ± 125 mA TMR 3-4823 ± 15 VDC ± 100 mA Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 2 + Vin (Vcc) + Vin (Vcc) 3 Remote On/Off Remote On/Off 5 No con. No con. 6 + Vout + Vout 7 – Vout Common 2.0 2 x 2.54 5.08 3 x 2.54 (0.08) (2 x 0.1) (0.2) (3 x 0.1) 8 No con. – Vout 21.8 (0.86) Bo ttom v ie w 12 35 67 8 0.5 (0.02) () = Inches 40 0.5 (0.02) 0.25(0.01) 4.0 11.2 (0.44) 3.2 (0.16) (0.13) 9.1 (0.36) www.tracopower.com SIP-Package DC/DC Converters TMR-3HI Series 3 W UL 60950-1 Wide 2:1 input range Fully regulated outputs 3’000 VDC I/O isolation Operating temperature range –40 °C to +85 °C No minimum load required Short circuit protection Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation – Single output models: 0.5 % max. TMR 3-0510HI 3.3 VDC 700 mA – Dual output models: 1.0 % max. TMR 3-0511HI 5 VDC 600 mA Ripple & noise <50 mVpk-pk (20 MHz BW) TMR 3-0512HI 12 VDC 250 mA no external output capacitor required TMR 3-0513HI 4.5 – 9.0 VDC 15 VDC 200 mA Short circuit protection continuous, automatic recovery TMR 3-0521HI ± 5 VDC ± 300 mA Efficiency 79 % typ. TMR 3-0522HI ± 12 VDC ± 125 mA Operating temperature –40 °C to +85 °C TMR 3-0523HI ± 15 VDC ± 100 mA range above 70 °C derating 3.3 %/K TMR 3-1210HI 3.3 VDC 700 mA TMR 3-1211HI 5 VDC 600 mA I/O isolation voltage 3000 VDC (60 sec.) functional insulation TMR 3-1212HI 12 VDC 250 mA I/O isolation capacitance 40 pF max. TMR 3-1213HI 9 – 18 VDC 15 VDC 200 mA I/O isolation resistance >10 GOhm TMR 3-1221HI ± 5 VDC ± 300 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 TMR 3-1222HI ± 12 VDC ± 125 mA approvals TMR 3-1223HI ± 15 VDC ± 100 mA Remote On/Off shutdown input for low input current (2.5 mA) TMR 3-2410HI 3.3 VDC 700 mA in standby operation TMR 3-2411HI 5 VDC 600 mA Casing plastic (UL 94 V-O rated) TMR 3-2412HI 12 VDC 250 mA Full datasheet www.tracopower.com/products/tmr3.pdf TMR 3-2413HI 18 – 36 VDC 15 VDC 200 mA TMR 3-2421HI ± 5 VDC ± 300 mA TMR 3-2422HI ± 12 VDC ± 125 mA TMR 3-2423HI ± 15 VDC ± 100 mA TMR 3-4810HI 3.3 VDC 700 mA TMR 3-4811HI 5 VDC 600 mA TMR 3-4812HI 12 VDC 250 mA TMR 3-4813HI 36 – 75 VDC 15 VDC 200 mA TMR 3-4821HI ± 5 VDC ± 300 mA TMR 3-4822HI ± 12 VDC ± 125 mA TMR 3-4823HI ± 15 VDC ± 100 mA Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 2 + Vin (Vcc) + Vin (Vcc) 3 Remote On/Off Remote On/Off 5 No Pin No Pin 6 + Vout + Vout 7 – Vout Common 2.0 2 x 2.54 5.08 3 x 2.54 (0.08) (2 x 0.1) (0.2) (3 x 0.1) 8 No con. – Vout 21.8 (0.86) Bo ttom v ie w 12 36 78 0.5 (0.02) () = Inches 41 0.5 (0.02) 0.25(0.01) 4.0 11.1 (0.44) 3.2 (0.16) (0.13) 9.2 (0.36) www.tracopower.com DC/DC Converters SIP-Package CB CB TMR-3WIE Series 3 W Schem Schemee UL 60950-1 Ultra wide 4:1 input range High quality/cost performance Fully regulated outputs I/O-isolation 1500 VDC Short circuit protection Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation 1.0 % max. (25-100% load) TMR 3-1210WIE 3.3 VDC 700 mA Ripple & noise <75 mVpk-pk (20 MHz BW) TMR 3-1211WIE 5 VDC 600 mA Short circuit protection continuous, automatic recovery TMR 3-1212WIE 12 VDC 250 mA Efficiency 78 % typ. TMR 3-1213WIE 4.5 – 18 VDC 15 VDC 200 mA 5 VDC input models: 74 % typ. TMR 3-1221WIE ± 5 VDC ± 300 mA TMR 3-1222WIE ± 12 VDC ± 125 mA Operating temperature –40 °C to +85 °C range above 70 °C derating 3.3 %/K TMR 3-1223WIE ± 15 VDC ± 100 mA TMR 3-2410WIE 3.3 VDC 700 mA I/O isolation voltage 1500 VDC (60 sec.) TMR 3-2411WIE 5 VDC 600 mA Safety standards UL 60950-1, IEC/EN 60950-1, CB-report TMR 3-2412WIE 12 VDC 250 mA Remote On/Off shutdown input for low input current (1 mA) TMR 3-2413WIE 9 – 36 VDC 15 VDC 200 mA in standby operation TMR 3-2421WIE ± 5 VDC ± 300 mA Casing plastic (UL 94 V-O rated) TMR 3-2422WIE ± 12 VDC ± 125 mA Full datasheet www.tracopower.com/products/tmr3wie.pdf TMR 3-2423WIE ± 15 VDC ± 100 mA TMR 3-4810WIE 3.3 VDC 700 mA TMR 3-4811WIE 5 VDC 600 mA TMR 3-4812WIE 12 VDC 250 mA TMR 3-4813WIE 18 – 75 VDC 15 VDC 200 mA TMR 3-4821WIE ± 5 VDC ± 300 mA TMR 3-4822WIE ± 12 VDC ± 125 mA TMR 3-4823WIE ± 15 VDC ± 100 mA Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 2 + Vin (Vcc) + Vin (Vcc) 3 Remote On/Off Remote On/Off 5 No con. No con. 2.0 6 + Vout + Vout (0.08) 2 x 2.54 5.08 3 x 2.54 (2 x 0.1)( (0.2) 3 x 0.1) 7 – Vout Common 8 No con. – Vout Bottom view 0.5 (0.02) 12 36 5 78 0.5 20.8 (0.82) (0.02) 21.8 (0.86) () = Inches 42 0.25 0.5 (0.02) (0.01) 2.7 3.2 11.2 (0.44) (0.11) (0.13) 9.3 (0.37) www.tracopower.com SIP-Package DC/DC Converters TMR-3WI Series 3 W UL 60950-1 Ultra wide 4:1 input range Fully regulated outputs I/O isolation 1500 VDC No minimum load required Short circuit protection Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation 1.0 % max. TMR 3-1210WI 3.3 VDC 700 mA Ripple & noise <75 mVpk-pk (20 MHz BW) TMR 3-1211WI 5 VDC 600 mA Short circuit protection continuous, automatic recovery TMR 3-1212WI 12 VDC 250 mA Efficiency 80 % typ. TMR 3-1213WI 4.5 – 18 VDC 15 VDC 200 mA TMR 3-1221WI ± 5 VDC ± 300 mA Operating temperature –40 °C to +85 °C range above 70 °C derating 3.3 %/K TMR 3-1222WI ± 12 VDC ± 125 mA I/O isolation voltage 1500 VDC (60 sec.) TMR 3-1223WI ± 15 VDC ± 100 mA TMR 3-2410WI 3.3 VDC 700 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 TMR 3-2411WI 5 VDC 600 mA Remote On/Off shutdown input for low input current (1 mA) TMR 3-2412WI 12 VDC 250 mA in standby operation TMR 3-2413WI 9 – 36 VDC 15 VDC 200 mA Casing plastic (UL 94 V-O rated) TMR 3-2421WI ± 5 VDC ± 300 mA Full datasheet www.tracopower.com/products/tmr3wi.pdf TMR 3-2422WI ± 12 VDC ± 125 mA TMR 3-2423WI ± 15 VDC ± 100 mA TMR 3-4810WI 3.3 VDC 700 mA TMR 3-4811WI 5 VDC 600 mA TMR 3-4812WI 12 VDC 250 mA TMR 3-4813WI 18 – 75 VDC 15 VDC 200 mA TMR 3-4821WI ± 5 VDC ± 300 mA TMR 3-4822WI ± 12 VDC ± 125 mA TMR 3-4823WI ± 15 VDC ± 100 mA Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 2 + Vin (Vcc) + Vin (Vcc) 3 Remote On/Off Remote On/Off 5 No con. No con. 6 + Vout + Vout 7 – Vout Common 2.0 2 x 2.54 5.08 3 x 2.54 (0.08) (2 x 0.1) (0.2) (3 x 0.1) 8 No con. – Vout 21.8 (0.86) Bo ttom v ie w 12 35 67 8 0.5 (0.02) () = Inches 43 0.5 (0.02) 0.25(0.01) 4.1 11.2 (0.44) 3.2 (0.16) (0.13) 9.1 (0.36) www.tracopower.com DC/DC Converters SIP-Package CB TMR-6 Series 6 W Scheme UL 60950-1 High power density Smallest footprint 6 W converter Wide 2:1 input range Fully regulated outputs I/O isolation 1500 VDC No minimum load required Input under voltage lockout Optional metal case with case pin connection Short circuit protection Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation 1 % max. TMR 6-0510 3.3 VDC 1300 mA Ripple & noise <50 mVpk-pk (20 MHz BW) TMR 6-0511 5 VDC 1200 mA no external output capacitor required TMR 6-0519 9 VDC 666 mA TMR 6-0512 12 VDC 500 mA Short circuit protection continuous, automatic recovery TMR 6-0513 4.5 – 9 VDC 15 VDC 400 mA Efficiency 83 % typ. TMR 6-0515 24 VDC 250 mA Operating temperature –40 °C to +65 °C (without derating) TMR 6-0521 ± 5 VDC ± 600 mA range above 65 °C derating 5 %/K TMR 6-0522 ± 12 VDC ± 250 mA I/O isolation voltage 1500 VDC (60 sec.) TMR 6-0523 ± 15 VDC ± 200 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 TMR 6-1210 3.3 VDC 1300 mA approvals TMR 6-1211 5 VDC 1200 mA TMR 6-1219 9 VDC 666 mA Remote On/Off shutdown input for low input current (2.5 mA) TMR 6-1212 12 VDC 500 mA in standby operation TMR 6-1213 9 – 18 VDC 15 VDC 400 mA Casing plastic (UL 94 V-O rated), Metal case on demand TMR 6-1215 24 VDC 250 mA Full datasheet www.tracopower.com/products/tmr6.pdf TMR 6-1221 ± 5 VDC ± 600 mA TMR 6-1222 ± 12 VDC ± 250 mA TMR 6-1223 ± 15 VDC ± 200 mA TMR 6-2410 3.3 VDC 1300 mA TMR 6-2411 5 VDC 1200 mA TMR 6-2419 9 VDC 666 mA TMR 6-2412 12 VDC 500 mA TMR 6-2413 18 – 36 VDC 15 VDC 400 mA TMR 6-2415 24 VDC 250 mA TMR 6-2421 ± 5 VDC ± 600 mA TMR 6-2422 ± 12 VDC ± 250 mA TMR 6-2423 ± 15 VDC ± 200 mA TMR 6-4810 3.3 VDC 1300 mA TMR 6-4811 5 VDC 1200 mA TMR 6-4819 9 VDC 666 mA TMR 6-4812 12 VDC 500 mA Dimensions TMR 6-4813 36 – 75 VDC 15 VDC 400 mA TMR 6-4815 24 VDC 250 mA TMR 6-4821 ± 5 VDC ± 600 mA TMR 6-4822 ± 12 VDC ± 250 mA TMR 6-4823 ± 15 VDC ± 200 mA On demand: Modules with metal casing Pin Single output Dual output 2.0 2 x 2.54 5.08 3 x 2.54 (0.08) (2 x 0.1) (0.2) (3 x 0.1) 1 – Vin (GND) – Vin (GND) 21.8 (0.86) 2 + Vin (Vcc) + Vin (Vcc) 3 Remote On/Off Remote On/Off Bo ttom v ie w 5 No con. No con. 12 35 67 8 6 + Vout + Vout 7 – Vout Common 0.5 (0.02) 8 No con. – Vout () = Inches 44 NEW Models 0.5 (0.02) 0.25(0.01) 4.1 11.2 (0.44) 3.2 (0.16) (0.13) 9.1 (0.36) www.tracopower.com SIP-Package DC/DC Converters CB TMR-6WI Series 6 W Scheme UL 60950-1 High power density Smallest footprint 6 W converter Ultra wide 4:1 input range I/O isolation 1500 VDC Operating temperature range –40 °C to +71 °C High efficiency up to 88% Short-circuit protection Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation 1 % max. TMR 6-2410WI 3.3 VDC 1500 mA Ripple & noise <125 mVpk-pk (20 MHz BW) TMR 6-2411WI 5 VDC 1200 mA TMR 6-2419WI 9 VDC 666 mA Conducted EMI EN55022, class A (internal filter) TMR 6-2412WI 12 VDC 500 mA Short circuit protection continuous, automatic recovery TMR 6-2413WI 9 – 36 VDC 15 VDC 400 mA Efficiency 85 % typ. TMR 6-2415WI 24 VDC 250 mA Operating temperature –40 °C to +71 °C (without derating) TMR 6-2421WI ± 5 VDC ± 600 mA range above 71 °C derating 3.5 %/K TMR 6-2422WI ± 12 VDC ± 250 mA I/O isolation voltage 1500 VDC (60 sec.) TMR 6-2423WI ± 15 VDC ± 200 mA TMR 6-4810WI 3.3 VDC 1500 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, reports pending TMR 6-4811WI 5 VDC 1200 mA approvals TMR 6-4819WI 9 VDC 666 mA Remote On/Off shutdown input for low input current (3 mA) TMR 6-4812WI 12 VDC 500 mA in standby operation TMR 6-4813WI 18 – 75 VDC 15 VDC 400 mA Casing plastic (UL 94 V-O rated), Metal case on demand TMR 6-4815WI 24 VDC 250 mA Full datasheet www.tracopower.com/products/tmr6wi.pdf TMR 6-4821WI ± 5 VDC ± 600 mA TMR 6-4822WI ± 12 VDC ± 250 mA TMR 6-4823WI ± 15 VDC ± 200 mA Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 2 + Vin (Vcc) + Vin (Vcc) 3 Remote On/Off Remote On/Off 5 No con. No con. 6 + Vout + Vout 7 – Vout Common 8 No con. – Vout 2.0 2 x 2.54 5.08 3 x 2.54 (0.08) (2 x 0.1) (0.2) (3 x 0.1) 21.8 (0.86) bottom view 12 35 67 8 0.5 (0.02) () = Inches 45 NEW Product 0.5 (0.02) 0.25 (0.01) 4.1 11.2 (0.44) 3.2 (0.16) (0.13) 9.1 (0.36) www.tracopower.com DC/DC Converters SIP-Package TMR-9 Series 9 W Highest power density in SIP package Smallest footprint 9 W converter Wide 2:1 input range Fully regulated outputs I/O isolation 1500 VDC Operating temperature range –40 °C to +71 °C No minimum load required Short circuit protection Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation 1 % max. TMR 9-1210 3.3 VDC 1800 mA Ripple & noise 75 mVpk-pk typ. (20 MHz BW) TMR 9-1211 5 VDC 1600 mA no external output capacitor required TMR 9-1219 9 VDC 1000 mA TMR 9-1212 12 VDC 750 mA Short circuit protection continuous, automatic recovery TMR 9-1213 9 – 18 VDC 15 VDC 600 mA Efficiency 86 % typ. TMR 9-1215 24 VDC 375 mA Operating temperature –40 °C to +71 °C TMR 9-1221 ± 5 VDC ± 800 mA range above 60 °C derating 4 %/K TMR 9-1222 ± 12 VDC ± 375 mA I/O isolation voltage 1500 VDC (60 sec.) TMR 9-1223 ± 15 VDC ± 300 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 TMR 9-2410 3.3 VDC 1800 mA approvals TMR 9-2411 5 VDC 1600 mA TMR 9-2419 9 VDC 1000 mA Remote On/Off shutdown input for low input current (3 mA) TMR 9-2412 12 VDC 750 mA in standby operation TMR 9-2413 18 – 36 VDC 15 VDC 600 mA Casing metal TMR 9-2415 24 VDC 375 mA Full datasheet www.tracopower.com/products/tmr9.pdf TMR 9-2421 ± 5 VDC ± 800 mA TMR 9-2422 ± 12 VDC ± 375 mA TMR 9-2423 ± 15 VDC ± 300 mA TMR 9-4810 3.3 VDC 1800 mA TMR 9-4811 5 VDC 1600 mA TMR 9-4819 9 VDC 1000 mA TMR 9-4812 12 VDC 750 mA TMR 9-4813 36 – 75 VDC 15 VDC 600 mA TMR 9-4815 24 VDC 375 mA TMR 9-4821 ± 5 VDC ± 800 mA TMR 9-4822 ± 12 VDC ± 375 mA TMR 9-4823 ± 15 VDC ± 300 mA Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 2 + Vin (Vcc) + Vin (Vcc) 3 Remote On/Off Remote On/Off 6 + Vout + Vout 7 – Vout Common 8 No con. – Vout 2.0 2 x 2.54 2 x 2.54 7.62 9 Case Case (2 x 0.1) (0.3) (2 x 0.1) (0.08) 21.8 (0.86) 10 Stand off Stand off 11 Stand off Stand off 10.6 (0.42) 12 Case Case 9 10 bottom viev 1 2 3 6 7 8 11 12 1.0 (0.04) 0.5 (0.02) () = Inches 46 NEW Product 0.25 (0.01) 0.5 (0.02) 3.3 4.1 11.2 (0.44) (0.13) (0.16) 9.6 (0.38) www.tracopower.com SIP-Package DC/DC Converters TMR-9WI Series 9 W Highest power density in SIP package Smallest footprint 9W converter Wide 4:1 input range Fully regulated outputs I/O isolation 1500 VDC Operating temperature range –40 °C to +71 °C No minimum load required Short circuit protection Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation 1 % max. TMR 9-2410WI 3.3 VDC 1800 mA Ripple & noise 75 mVpk-pk typ. (20 MHz BW) TMR 9-2411WI 5 VDC 1600 mA no external output capacitor required TMR 9-2419WI 9 VDC 1000 mA TMR 9-2412WI 12 VDC 750 mA Short circuit protection continuous, automatic recovery TMR 9-2413WI 9 – 36 VDC 15 VDC 600 mA Efficiency 86 % typ. TMR 9-2415WI 24 VDC 375 mA Operating temperature –40 °C to +71 °C TMR 9-2421WI ± 5 VDC ± 800 mA range above 60 °C derating 4 %/K TMR 9-2422WI ± 12 VDC ± 375 mA I/O isolation voltage 1500 VDC (60 sec.) TMR 9-2423WI ± 15 VDC ± 300 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 TMR 9-4810WI 3.3 VDC 1800 mA approvals TMR 9-4811WI 5 VDC 1600 mA TMR 9-4819WI 9 VDC 1000 mA Remote On/Off shutdown input for low input current (3 mA) TMR 9-4812WI 12 VDC 750 mA in standby operation TMR 9-4813WI 18 – 75 VDC 15 VDC 600 mA Casing metal TMR 9-4815WI 24 VDC 375 mA Full datasheet www.tracopower.com/products/tmr9wi.pdf TMR 9-4821WI ± 5 VDC ± 800 mA TMR 9-4822WI ± 12 VDC ± 375 mA TMR 9-4823WI ± 15 VDC ± 300 mA Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 2 + Vin (Vcc) + Vin (Vcc) 3 Remote On/Off Remote On/Off 6 + Vout + Vout 7 – Vout Common 8 No con. – Vout 2.0 2 x 2.54 2 x 2.54 7.62 (2 x 0.1) (0.3) (2 x 0.1) 9 Case Case (0.08) 21.8 (0.86) 10 Stand off Stand off 11 Stand off Stand off 10.6 (0.42) 12 Case Case 9 10 bottom viev 1 2 3 6 7 8 11 12 1.0 (0.04) 0.5 (0.02) () = Inches 47 NEW Product 0.25 (0.01) 0.5 (0.02) 4.1 11.2 (0.44) 3.3 (0.13) (0.16) 9.6 (0.38) www.tracopower.com DC/DC Converters High Performance CB CB TEL-2 Series 2 W Schem Schemee UL 60950-1 Low profile DIP-16 package Wide 2:1 input voltage range I/O isolation 1500 VDC Operating temperature range –40 °C to +75 °C Input filter to meet EN 55022, Class A Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. TEL 2-0510 3.3 VDC 500 mA Load regulation – Single output models: 0.75 % max. TEL 2-0511 5 VDC 400 mA – Dual output models: 2.0 % max. TEL 2-0512 12 VDC 165 mA Ripple & Noise <50 mVpk-pk (20 MHz BW) TEL 2-0513 4.5 – 9.0 VDC 15 VDC 135 mA Conducted EMI EN55022, class EN55022 class A (internal filter) TEL 2-0521 ± 5 VDC ± 200 mA Short circuit protection continuous, automatic recovery TEL 2-0522 ± 12 VDC ± 85 mA Efficiency 78 % typ. TEL 2-0523 ± 15 VDC ± 65 mA Operating temperature –40 °C to +75 °C TEL 2-1210 3.3 VDC 500 mA range above 65 °C derating 2.8 %/K TEL 2-1211 5 VDC 400 mA I/O isolation voltage 1500 VDC (60 sec.) TEL 2-1212 12 VDC 165 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report TEL 2-1213 9 – 18 VDC 15 VDC 135 mA approvals TEL 2-1221 ± 5 VDC ± 200 mA Casing plastic (UL 94 V-O rated) TEL 2-1222 ± 12 VDC ± 85 mA TEL 2-1223 ± 15 VDC ± 65 mA Full datasheet www.tracopower.com/products/tel2.pdf TEL 2-2410 3.3 VDC 500 mA TEL 2-2411 5 VDC 400 mA TEL 2-2412 12 VDC 165 mA Product with same electrical specifications available in TEL 2-2413 18 – 36 VDC 15 VDC 135 mA SMD package. TEL 2-2421 ± 5 VDC ± 200 mA See TES-2N series page 19 TEL 2-2422 ± 12 VDC ± 85 mA TEL 2-2423 ± 15 VDC ± 65 mA TEL 2-4810 3.3 VDC 500 mA TEL 2-4811 5 VDC 400 mA TEL 2-4812 12 VDC 165 mA TEL 2-4813 36 – 75 VDC 15 VDC 135 mA TEL 2-4821 ± 5 VDC ± 200 mA TEL 2-4822 ± 12 VDC ± 85 mA TEL 2-4823 ± 15 VDC ± 65 mA Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 7 No con. No con. 16 1 8 No con. Common 9 + Vout + Vout 10 – Vout – Vout 16 + Vin + Vin 10 7 9 8 0.5 (0.02) 1.77 10.16 (0.4) (0.07) 3.2 13.7 (0.54) 8.0 (0.13) (0.31) () = Inches 48 23.8 (0.94) 2.54 15.24 (0.6) 3.0 (0.1) (0.12) Bottom view 23.8 (0.94) www.tracopower.com High Performance DC/DC Converters TDR-2 Series 2 W UL 60950-1 Compact design in DIP-14 package Wide 2:1 input voltage range Fully regulated outputs Low ripple & noise 30mVpk-pk typ. No minimum load required I/O isolation 1500 VDC Operating temperature range –40 °C to +85 °C without derating Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation – Single output models: 1.0 % max. TDR 2-0511 5 VDC 400 mA – Dual output models: 1.0 % max. TDR 2-0512 12 VDC 167 mA Ripple & noise 30 mVpk-pk typ. (20 MHz BW) TDR 2-0513 4.5 – 9 VDC 15 VDC 134 mA (no external output capacitor required) TDR 2-0522 ± 12 VDC ± 83 mA Short circuit protection continuous, automatic recovery TDR 2-0523 ± 15 VDC ± 67 mA Efficiency 83 % typ. TDR 2-1211 5 VDC 400 mA Operating temperature –40 °C to +85 °C without derating TDR 2-1212 12 VDC 167 mA range TDR 2-1213 9 – 18 VDC 15 VDC 134 mA I/O isolation voltage 1500 VDC (60 sec.) TDR 2-1222 ± 12 VDC ± 83 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 TDR 2-1223 ± 15 VDC ± 67 mA Remote On/Off shutdown input for low input current (2.5 mA) TDR 2-2411 5 VDC 400 mA in standby operation TDR 2-2412 12 VDC 167 mA Casing plastic over mold (UL 94 V-O rated) TDR 2-2413 18 – 36 VDC 15 VDC 134 mA TDR 2-2422 ± 12 VDC ± 83 mA Full datasheet www.tracopower.com/products/tdr2.pdf TDR 2-2423 ± 15 VDC ± 67 mA TDR 2-4811 5 VDC 400 mA TDR 2-4812 12 VDC 167 mA TDR 2-4813 36 – 75 VDC 15 VDC 134 mA Product with same electrical specifications available in TDR 2-4822 ± 12 VDC ± 83 mA SMD package. TDR 2-4823 ± 15 VDC ± 67 mA See TDR-2SM series page 20 Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 8.7 (0.35) 3.8 13.55 (0.533) 2 Remote On/Off Remote On/Off (0.15) 12.8 (0.50) 6 No con. Common 7 No con. – Vout 8 7 8 + Vout + Vout 9 6 9 – Vout Common 14 + Vin (Vcc) + Vin (Vcc) 2 14 1 () = Inches 49 1.3 (0.05) 0.8(0.03) 1.8 2.54 10.16 2.54 (0.07)(0.1) (0.4) (0.1) top view 18.9 (0.74) www.tracopower.com DC/DC Converters High Performance TDR-2WI Series 2 W UL 60950-1 Compact design in DIP-14 package Ultra wide 4:1 input voltage range Fully regulated outputs Low ripple & noise 30 MVpk-pk typ. No minimum load required I/O isolation 1500 VDC Operating temperature range –40 °C to +85 °C without derating Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation – Single output models: 1.0 % max. TDR 2-1211WI 5 VDC 400 mA – Dual output models: 1.0 % max. TDR 2-1212WI 12 VDC 167 mA Ripple & noise 30 mVpk-pk typ. (20 MHz BW) TDR 2-1213WI 4.5 – 18 VDC 15 VDC 134 mA (no external output capacitor required) TDR 2-1222WI ± 12 VDC ± 83 mA Short circuit protection continuous, automatic recovery TDR 2-1223WI ± 15 VDC ± 67 mA Efficiency 81 % typ. TDR 2-2411WI 5 VDC 400 mA Operating temperature –40 °C to +85 °C without derating TDR 2-2412WI 12 VDC 167 mA range TDR 2-2413WI 9 – 36 VDC 15 VDC 134 mA I/O isolation voltage 1500 VDC (60 sec.) TDR 2-2422WI ± 12 VDC ± 83 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 TDR 2-2423WI ± 15 VDC ± 67 mA Remote On/Off shutdown input for low input current (2.5 mA) TDR 2-4811WI 5 VDC 400 mA in standby operation TDR 2-4812WI 12 VDC 167 mA Casing plastic over mold (UL 94 V-O rated) TDR 2-4813WI 18 – 75 VDC 15 VDC 134 mA TDR 2-4822WI ± 12 VDC ± 83 mA Full datasheet www.tracopower.com/products/tdr2wi.pdf TDR 2-4823WI ± 15 VDC ± 67 mA Product with same electrical specifications available in SMD package. See TDR-2WISM series page 21 Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 8.7 (0.35) 3.8 13.55 (0.533) 2 Remote On/Off Remote On/Off (0.15) 12.8 (0.50) 6 No con. Common 7 No con. – Vout 8 7 8 + Vout + Vout 9 6 9 – Vout Common 14 + Vin (Vcc) + Vin (Vcc) 2 14 1 () = Inches 50 1.3 (0.05) 0.8(0.03) 1.8 2.54 10.16 2.54 (0.07)(0.1) (0.4) (0.1) top view 18.9 (0.74) www.tracopower.com High Performance DC/DC Converters TDR-3 Series 3 W UL 60950-1 Smallest 3 Watt converter in DIP-14 package Wide 2:1 input voltage range Fully regulated outputs Low ripple & noise 30mVpk-pk typ. No minimum load required I/O isolation 1500 VDC Operating temperature range –40 °C to +85 °C Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation – Single output models: 1.0 % max. TDR 3-0511 5 VDC 600 mA – Dual output models: 1.0 % max. TDR 3-0512 12 VDC 250 mA Ripple & noise 30 mVpk-pk typ. (20 MHz BW) TDR 3-0513 4.5 – 9 VDC 15 VDC 200 mA (no external output capacitor required) TDR 3-0522 ± 12 VDC ± 125 mA Short circuit protection continuous, automatic recovery TDR 3-0523 ± 15 VDC ± 100 mA Efficiency 83 % typ. TDR 3-1211 5 VDC 600 mA Operating temperature –40 °C to +85 °C TDR 3-1212 12 VDC 250 mA range above 70 °C derating 3.5%/K TDR 3-1213 9 – 18 VDC 15 VDC 200 mA I/O isolation voltage 1500 VDC (60 sec.) TDR 3-1222 ± 12 VDC ± 125 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 CB-report TDR 3-1223 ± 15 VDC ± 100 mA Remote On/Off shutdown input for low input current (2.5 mA) TDR 3-2411 5 VDC 600 mA in standby operation TDR 3-2412 12 VDC 250 mA Casing Epoxy molded (UL 94 V-O rated) TDR 3-2413 18 – 36 VDC 15 VDC 200 mA TDR 3-2422 ± 12 VDC ± 125 mA Full datasheet www.tracopower.com/products/tdr3.pdf TDR 3-2423 ± 15 VDC ± 100 mA TDR 3-4811 5 VDC 600 mA TDR 3-4812 12 VDC 250 mA TDR 3-4813 36 – 75 VDC 15 VDC 200 mA Product with same electrical specifications available in TDR 3-4822 ± 12 VDC ± 125 mA SMD package. TDR 3-4823 ± 15 VDC ± 100 mA See TDR-3SM series page 22 Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 8.7 (0.35) 3.8 13.55 (0.533) 2 Remote On/Off Remote On/Off (0.15) 12.8 (0.50) 6 No con. Common 7 No con. – Vout 8 7 8 + Vout + Vout 9 6 9 – Vout Common 14 + Vin (Vcc) + Vin (Vcc) 2 14 1 () = Inches 51 1.3 (0.05) 0.8(0.03) 1.8 2.54 10.16 2.54 (0.07)(0.1) (0.4) (0.1) top view 18.9 (0.74) www.tracopower.com DC/DC Converters High Performance TDR-3WI Series 3 W UL 60950-1 Smallest 3 Watt converter in DIP-14 package Ultra wide 4:1 input voltage range Fully regulated outputs Low ripple & noise No minimum load required I/O isolation 1500 VDC Operating temperature range –40 °C to +85 °C Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation – Single output models: 1.0 % max. TDR 3-1211WI 5 VDC 600 mA – Dual output models: 1.0 % max. TDR 3-1212WI 12 VDC 250 mA Ripple & noise <30 mVpk-pk (20 MHz BW) TDR 3-1213WI 4.5 – 18 VDC 15 VDC 200 mA (no external output capacitor required) TDR 3-1222WI ± 12 VDC ± 125 mA Short circuit protection continuous, automatic recovery TDR 3-1223WI ± 15 VDC ± 100 mA Efficiency 82 % typ. TDR 3-2411WI 5 VDC 600 mA Operating temperature –40 °C to +85 °C TDR 3-2412WI 12 VDC 250 mA range above 70 °C derating 3.5%/K TDR 3-2413WI 9 – 36 VDC 15 VDC 200 mA I/O isolation voltage 1500 VDC (60 sec.) TDR 3-2422WI ± 12 VDC ± 125 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 TDR 3-2423WI ± 15 VDC ± 100 mA Remote On/Off shutdown input for low input current (2.5 mA) TDR 3-4811WI 5 VDC 600 mA in standby operation TDR 3-4812WI 12 VDC 250 mA Casing plastc over mold (UL 94 V-O rated) TDR 3-4813WI 18 – 75 VDC 15 VDC 200 mA TDR 3-4822WI ± 12 VDC ± 125 mA Full datasheet www.tracopower.com/products/tdr3wi.pdf TDR 3-4823WI ± 15 VDC ± 100 mA Product with same electrical specifications available in SMD package. See TDR-3WISM series page 23 Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 8.7 (0.35) 3.8 13.55 (0.533) 2 Remote On/Off Remote On/Off (0.15) 12.8 (0.50) 6 No con. Common 7 No con. – Vout 8 7 8 + Vout + Vout 9 6 9 – Vout Common 14 + Vin (Vcc) + Vin (Vcc) 2 14 1 () = Inches 52 1.3 (0.05) 0.8(0.03) 1.8 2.54 10.16 2.54 (0.07)(0.1) (0.4) (0.1) top view 18.9 (0.74) www.tracopower.com High Performance DC/DC Converters C CBB THL-3WI Series 3 W Schem Schemee UL 60950-1 DIP-16 package, low profile Ultra wide 4:1 input voltage range Fully regulated outputs I/O-isolation 1500 VDC Input filter to meet EN 55022, class A Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5% max. max. Load regulation 1.5% max. THL 3-2410WI 3.3 VDC 600 mA Ripple & noise <60 mVpk-pk (20 MHz BW) THL 3-2411WI 5 VDC 600 mA Conducted EMI EN55022 class A THL 3-2412WI 12 VDC 250 mA Short circuit protection continuous, automatic recovery THL 3-2413WI 9 – 36 VDC 15 VDC 200 mA THL 3-2415WI 24 VDC 125 mA Efficiency 81 % typ. THL 3-2421WI ± 5 VDC ± 300 mA Operating temperature –40 °C to +85 °C range above 65 °C derating 2.9%/K THL 3-2422WI ± 12 VDC ± 125 mA THL 3-2423WI ± 15 VDC ± 100 mA I/O isolation voltage 1500 VDC (60 sec.) THL 3-4810WI 3.3 VDC 600 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 CB-report THL 3-4811WI 5 VDC 600 mA Remote On/Off shutdown input for low input current (5 mA) THL 3-4812WI 12 VDC 250 mA in standby operation THL 3-4813WI 18 – 75 VDC 15 VDC 200 mA Casing plastic over mold (UL 94 V-O rated) THL 3-4815WI 24 VDC 125 mA Full datasheet www.tracopower.com/products/thl3wi.pdf THL 3-4821WI ± 5 VDC ± 300 mA THL 3-4822WI ± 12 VDC ± 125 mA THL 3-4823WI ± 15 VDC ± 100 mA Product with same electrical specifications available in SMD package. See THL-3WISM series page 24 Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 2 Remote On/Off Remote On/Off 16 1 7 No con. No con. 2 8 No con. Common 9 + Vout + Vout 10 – Vout – Vout 16 + Vin (Vcc) + Vin (Vcc) 10 7 9 8 0.5 1.77 10.16 (0.4) (0.02) (0.07) 4.1 8.0 13.7 (0.54) (0.16) (0.31) () = Inches 53 2.54 12.70 (0.5) 2.54 (0.1) (0.1) 3.0 (0.12) 23.8 (0.94) bottom view www.tracopower.com DC/DC Converters High Performance CB CB TEM-3N Series 3 W Schem Schemee UL 60950-1 Cost optimized design in DIP–24 package Operating temperature range –40 °C to +75 °C without derating short circuit protection Input filter to meet EN 55022, class A Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation 0.5 % max. TEM 3-0511N 5 VDC 600 mA Ripple & Noise 60 mVpk-pk max. (20 MHz BW) TEM 3-0512N 12 VDC 250 mA Input filter EN 55022 class A TEM 3-0513N 5 VDC ± 10% 15 VDC 200 mA Short circuit protection continuous, automatic recovery TEM 3-0522N ± 12 VDC ± 125 mA TEM 3-0523N ± 15 VDC ± 100 mA Efficiency 79 % typ. TEM 3-1211N 5 VDC 600 mA Operating temperature –40 °C to +85 °C range above 75 °C derating 5 %/K TEM 3-1212N 12 VDC 250 mA TEM 3-1213N 12 VDC ± 10% 15 VDC 200 mA I/O isolation voltage 1500 VDC (60 sec.) TEM 3-1222N ± 12 VDC ± 125 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report TEM 3-1223N ± 15 VDC ± 100 mA approvals TEM 3-2411N 5 VDC 600 mA Casing plastic (UL 94 V-O rated) TEM 3-2412N 12 VDC 250 mA Full datasheet www.tracopower.com/products/tem3n.pdf TEM 3-2413N 24 VDC ± 10% 15 VDC 200 mA TEM 3-2422N ± 12 VDC ± 125 mA TEM 3-2423N ± 15 VDC ± 100 mA Dimensions Pin Single output Dual output 1 2 3 10 11 12 1 + Vin (Vcc) + Vin (Vcc) 2 No con. – Vout Bottom View 3 No con. Common 24 23 22 15 14 13 10 – Vout Common 11 + Vout + Vout 12 – Vin (GND) – Vin (GND) 13 – Vin (GND) – Vin (GND) 14 + Vout + Vout 15 – Vout Common 22 No con. Common 23 No con. – Vout 2.54 2.54 17.78 (0.7) 2.54 2.54 24 + Vin (Vcc) + Vin (Vcc) (0.1) (0.1) (0.1) (0.1) 27.94 (1.1) 2.0 (0.079) 32.0 (1.26) () = Inches 54 NEW Product 2.4 15.24 (0.6) (0.094) 10.2 0.5 4.5 20.0 (0.787) (0.18) (0.4 0.02) www.tracopower.com High Performance DC/DC Converters C CBB TEL-3 Series 3 W Schem Schemee UL 60950-1 Wide 2:1 input range Cost optimized design I/O isolation 1500 VDC Operating temperature range –40 °C to +85 °C Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation – Single output models: 0.5 % max. TEL 3-0511 5 VDC 600 mA – Dual output models: 1.0 % max. TEL 3-0512 12 VDC 250 mA Ripple & Noise 60 mVpk-pk max. (20 MHz BW) TEL 3-0513 4.5 – 9.0 VDC 15 VDC 200 mA Input filter Pi-filter TEL 3-0522 ± 12 VDC ± 125 mA Short circuit protection continuous, automatic recovery TEL 3-0523 ± 15 VDC ± 100 mA Efficiency 80 % typ. TEL 3-1211 5 VDC 600 mA TEL 3-1212 12 VDC 250 mA Operating temperature –40 °C to +85 °C range above 70 °C derating 3.3 %/K TEL 3-1213 9 – 18 VDC 15 VDC 200 mA I/O isolation voltage 1500 VDC (60 sec.) TEL 3-1222 ± 12 VDC ± 125 mA TEL 3-1223 ± 15 VDC ± 100 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report TEL 3-2011 5 VDC 600 mA approvals TEL 3-2012 12 VDC 250 mA Casing plastic (UL 94 V-O rated) TEL 3-2013 10 – 30 VDC 15 VDC 200 mA Full datasheet www.tracopower.com/products/tel3.pdf TEL 3-2022 ± 12 VDC ± 125 mA TEL 3-2023 ± 15 VDC ± 100 mA TEL 3-2411 5 VDC 600 mA TEL 3-2412 12 VDC 250 mA TEL 3-2413 18 – 36 VDC 15 VDC 200 mA TEL 3-2422 ± 12 VDC ± 125 mA TEL 3-2423 ± 15 VDC ± 100 mA TEL 3-4811 5 VDC 600 mA TEL 3-4812 12 VDC 250 mA TEL 3-4813 36 – 75 VDC 15 VDC 200 mA TEL 3-4822 ± 12 VDC ± 125 mA TEL 3-4823 ± 15 VDC ± 100 mA Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 2 No con. – Vout 3 No con. Common 24 1 23 2 10 – Vout Common 22 3 11 + Vout + Vout 12 – Vin (GND) – Vin (GND) 13 – Vin (GND) – Vin (GND) 14 + Vout + Vout 15 10 14 11 15 – Vout Common 13 12 22 No con. Common 2.4 15 .24 23 No con. – Vout (0.6) (0.1) 24 + Vin (Vcc) + Vin (Vcc) 4.5 10.2 20 (0.4) (0.79) (0.18) () = Inches 55 32 (1.25) 27.94 2.0 (1.1) (0.08) 2.54 2.54 2.54 17.78 2.54 (0.1) (0.1) (0.7) (0.1) (0.1) Bottom view www.tracopower.com DC/DC Converters High Performance CB CB TEN-3N Series 3 W Schem Schemee UL 60950-1 Wide 2:1 input voltage range I/O-isolation 1500 VDC or 3000 VDC Operating temperature range –40 °C to +85 °C Short-circuit protection No minimum load required Input filter to meet EN 55022, class A Specifications Models Order code Input voltage Output voltage Output current Line regulation 1% max. max. Load regulation 1% max. TEN 3-0510N 3.3 VDC 750 mA Ripple & noise <70 mVpk-pk (20 MHz BW) TEN 3-0511N* 5 VDC 600 mA TEN 3-0512N* 12 VDC 250 mA Conducted EMI EN55022 class A TEN 3-0513N* 4.5 – 9.0 VDC 15 VDC 200 mA Short circuit protection continuous, automatic recovery TEN 3-0515N* 24 VDC 125 mA Efficiency 82 % typ. TEN 3-0521N* ± 5 VDC ± 250 mA TEN 3-0522N* ± 12 VDC ± 125 mA Operating temperature –40 °C to +85 °C TEN 3-0523N* ± 15 VDC ± 100 mA range above 70 °C derating 3.3%/K TEN 3-1210N 3.3 VDC 750 mA I/O isolation voltage 1500 VDC (60 sec.) or 3000 VDC (functional isolation) TEN 3-1211N 5 VDC 600 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 CB-report TEN 3-1212N 12 VDC 250 mA TEN 3-1213N 9 – 18 VDC 15 VDC 200 mA Casing plastic (UL 94 V-O rated) TEN 3-1215N 24 VDC 125 mA Full datasheet www.tracopower.com/products/ten3n.pdf TEN 3-1221N ± 5 VDC ± 250 mA TEN 3-1222N ± 12 VDC ± 125 mA TEN 3-1223N ± 15 VDC ± 100 mA TEN 3-2410N 3.3 VDC 750 mA TEN 3-2411N 5 VDC 600 mA TEN 3-2412N 12 VDC 250 mA TEN 3-2413N 18 – 36 VDC 15 VDC 200 mA TEN 3-2415N 24 VDC 125 mA TEN 3-2421N ± 5 VDC ± 250 mA TEN 3-2422N ± 12 VDC ± 125 mA TEN 3-2423N ± 15 VDC ± 100 mA TEN 3-4810N 3.3 VDC 7500 mA TEN 3-4811N 5 VDC 600 mA TEN 3-4812N 12 VDC 250 mA TEN 3-4813N 36 – 75 VDC 15 VDC 200 mA TEN 3-4815N 24 VDC 125 mA TEN 3-4821N ± 5 VDC ± 250 mA TEN 3-4822N ± 12 VDC ± 125 mA TEN 3-4823N ± 15 VDC ± 100 mA * for 3000 VDC I/O isolation add suffix -HI Dimensions Pin Single output Dual output 23 911 2 – Vin (GND) – Vin (GND) Bottom view 3 – Vin (GND) – Vin (GND) 9 No pin Common 23 22 16 14 11 No con. – Vout 14 + Vout + Vout 16 – Vout Common 22 + Vin (Vcc) + Vin (Vcc) 23 + Vin (Vcc) + Vin (Vcc) 2.54 15.24 (0.6) 5.08 (0.1) (0.2) 4.5 22.86 (0.9) (0.18 ) 31.8 (1.25) () = Inches 56 NEW Product 2.54 15.24 (0.6) (0.1) 10.2 20.3 4.5 (0.4 ) (0.8 ) (0.18) www.tracopower.com High Performance DC/DC Converters C CBB TEN-3WIN Series 3 W Schem Schemee UL 60950-1 Ultra wide 4:1 input voltage range I/O-isolation 1500 VDC or 3000 VDC Operating temperature range –40 °C to +85 °C Short-circuit protection No minimum load required Input filter to meet EN 55022, class A Specifications Models Order code Input voltage Output voltage Output current Line regulation 1% max. max. Load regulation 1% max. TEN 3-2410WIN 3.3 VDC 750 mA Ripple & noise <70 mVpk-pk (20 MHz BW) TEN 3-2411WIN* 5 VDC 600 mA Conducted EMI EN55022 class A TEN 3-2412WIN* 12 VDC 250 mA Short circuit protection continuous, automatic recovery TEN 3-2413WIN* 9.0 – 36 VDC 15 VDC 200 mA TEN 3-2415WIN* 24 VDC 125 mA Efficiency 81 % typ. TEN 3-2421WIN* ± 5 VDC ± 250 mA Operating temperature –40 °C to +85 °C range above 70 °C derating 3.3%/K TEN 3-2422WIN* ± 12 VDC ± 125 mA TEN 3-2423WIN* ± 15 VDC ± 100 mA I/O isolation voltage 1500 VDC (60 sec.) or 3000 VDC (functional isolation) TEN 3-4810WIN 3.3 VDC 750 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 CB-report TEN 3-4811WIN* 5 VDC 600 mA Casing plastic (UL 94 V-O rated) TEN 3-4812WIN* 12 VDC 250 mA Full datasheet www.tracopower.com/products/ten3win.pdf TEN 3-4813WIN* 18 – 75 VDC 15 VDC 200 mA TEN 3-4815WIN* 24 VDC 125 mA TEN 3-4821WIN* ± 5 VDC ± 250 mA TEN 3-4822WIN* ± 12 VDC ± 125 mA TEN 3-4823WIN* ± 15 VDC ± 100 mA * for 3000 VDC I/O isolation add suffix -HI Dimensions Pin Single output Dual output 23 911 2 – Vin (GND) – Vin (GND) Bottom view 3 – Vin (GND) – Vin (GND) 9 No pin Common 23 22 16 14 11 No con. – Vout 14 + Vout + Vout 16 – Vout Common 22 + Vin (Vcc) + Vin (Vcc) 23 + Vin (Vcc) + Vin (Vcc) 2.54 15.24 (0.6) 5.08 (0.1) (0.2) 4.5 22.86 (0.9) (0.18 ) 31.8 (1.25) () = Inches 57 NEW Product 2.54 15.24 (0.6) (0.1) 20.3 10.2 4.5 (0.4 ) (0.18) (0.8 ) www.tracopower.com DC/DC Converters High Performance CB Scheme TVN-5WI Series 5 W UL 60950-1 Ultra low ripple & noise 10 mVpp typ. 6-side shielded metal casing Input filter to meet EN 55022 class B Ultra wide 4:1 input voltage range High efficiency up to 88% Operating temperature range –40 °C to +85 °C without derating I/O isolation 1500 VDC No minimum load required Undervoltage lockout Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation 1 % max. TVN 5-2410WI 3.3 VDC 1515 mA Ripple & noise 10 mVpk-pk typ. (20 MHz BW) TVN 5-2411WI 5 VDC 1000 mA no external output capacitor required TVN 5-2412WI 12 VDC 416 mA TVN 5-2413WI 15 VDC 333 mA Input filter EN 55022, class B TVN 5-2415WI 9 – 36 VDC 24 VDC 208 mA Short circuit protection continuous, automatic recovery TVN 5-2421WI ± 5 VDC ± 500 mA Efficiency 85 % typ. TVN 5-2422WI ± 12 VDC ± 208 mA Operating temperature –40 °C to +85 °C (without derating) TVN 5-2423WI ± 15 VDC ± 166 mA range TVN 5-2425WI ± 24 VDC ± 104 mA I/O isolation voltage 1500 VDC (60 sec.) TVN 5-4810WI 3.3 VDC 1515 mA TVN 5-4811WI 5 VDC 1000 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 TVN 5-4812WI 12 VDC 416 mA approvals TVN 5-4813WI 15 VDC 333 mA Remote On/Off shutdown input for low input current (3 mA) TVN 5-4815WI 18 – 75 VDC 24 VDC 208 mA in standby operation TVN 5-4821WI ± 5 VDC ± 500 mA Casing 6 side shielded metal casing TVN 5-4822WI ± 12 VDC ± 208 mA Full datasheet www.tracopower.com/products/tvn5wi.pdf TVN 5-4823WI ± 15 VDC ± 166 mA TVN 5-4825WI ± 24 VDC ± 104 mA Dimensions Pin Single output Dual output 1 2 3 10 11 12 1 + Vin (Vcc) + Vin (Vcc) 2 + Vin (Vcc) + Vin (Vcc) Bottom View 3 Case Case 24 23 22 15 14 13 10 No pin Common 11 No pin + Vout 1 12 Case Case 13 Trim Trim 14 – Vout – Vout 2 15 + Vout Common 22 Remote On/Off Remote On/Off 23 – Vin – Vin 2.54 2.54 17.78 (0.7) 2.54 2.54 24 – Vin – Vin (0.1) (0.1) (0.1) (0.1) 27.94 (1.1) 2.0 (0.079) 32.0 (1.26) () = Inches 58 NEW Product 15.24 (0.6) 2.4 (0.094) 10.2 0.5 20.0 (0.787) 4.5 (0.18) (0.4 0.02) www.tracopower.com High Performance DC/DC Converters CB CB TEL-5 Series 5 – 6 W Schem Schemee UL 60950-1 Wide 2:1 input range High efficiency up to 86 % I/O isolation 1500 VDC Operating temperature range –40 °C to +85 °C Industry standard pinout Cost optimized design Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.3 % max. max. Load regulation – Single output models: 1.0 % max. TEL 5-1210 3.3 VDC 1200 mA – Dual output models: 2.0 % max. TEL 5-1211 5 VDC 1000 mA Ripple & noise <75 mVpk-pk (20 MHz BW) TEL 5-1212 9 – 18 VDC 12 VDC 500 mA Input filter Pi-filter TEL 5-1222 ± 12 VDC ± 250 mA Short circuit protection continuous, automatic recovery TEL 5-1223 ± 15 VDC ± 200 mA Efficiency 84 % typ. TEL 5-2410 3.3 VDC 1200 mA Operating temperature –40 °C to +85 °C TEL 5-2411 5 VDC 1000 mA range above 70 °C derating 3.3 %/K TEL 5-2412 18 – 36 VDC 12 VDC 500 mA TEL 5-2422 ± 12 VDC ± 250 mA I/O isolation voltage 1500 VDC (60 sec.) TEL 5-2423 ± 15 VDC ± 200 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report approvals Casing plastic (UL 94V-O rated) Full datasheet www.tracopower.com/products/tel5.pdf Dimensions Pin Single output Dual output 2 – Vin (GND) – Vin (GND) 3 – Vin (GND) – Vin (GND) 9 No pin Common 23 2 11 No con. – Vout 3 22 14 + Vout + Vout 16 – Vout Common 22 + Vin (Vcc) + Vin (Vcc) 16 9 23 + Vin (Vcc) + Vin (Vcc) 14 11 2.4 15 .24 (0.6) (0.1) 5 10.2 20.3 (0.2) (0.4) (0.8) () = Inches 59 32 (1.25) 22.86 4.5 (0.9) (0.18) 15.24 5.08 2.54 (0.2) (0.6) (0.1) Bottom view www.tracopower.com DC/DC Converters High Performance CB TEN-6N Series 6 W Scheme UL 60950-1 Wide 2:1 input range Operating temperature range –40 C to +85 °C I/O isolation 1500 VDC Input filter to meet EN 55022, class A Industry standard pinout Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation single output: 1.2 % max. TEN 6-1210N 3.3 VDC 1200 mA dual output: 2% max. TEN 6-1211N 5 VDC 1200 mA Ripple & noise <80 mVpk-pk (20 MHz BW) TEN 6-1212N 12 VDC 500 mA Conducted EMI EN 55022, class EN55022 class A (internal filter) TEN 6-1213N 9 – 18 VDC 15 VDC 400 mA Short circuit protection continuous TEN 6-1215N 24 VDC 250 mA Efficiency 84 % typ. TEN 6-1221N ± 5 VDC ± 500 mA 3.3 VDC models 77 % typ. TEN 6-1222N ± 12 VDC ± 250 mA Operating temperature –40 °C to +85 °C TEN 6-1223N ± 15 VDC ± 200 mA range 3.3 & 5.0 VDC models, above 60°C derating 2.5 %/K TEN 6-2410N 3.3 VDC 1200 mA other models, above 70°C derating 3.3 %/K TEN 6-2411N 5 VDC 1200 mA I/O isolation voltage 1500 VDC (60 sec.) TEN 6-2412N 12 VDC 500 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report TEN 6-2413N 18 – 36 VDC 15 VDC 400 mA approvals TEN 6-2415N 24 VDC 250 mA Casing plastic (UL 94 V-O rated) TEN 6-2421N ± 5 VDC ± 500 mA Full datasheet www.tracopower.com/products/ten6n.pdf TEN 6-2422N ± 12 VDC ± 250 mA TEN 6-2423N ± 15 VDC ± 200 mA TEN 6-4810N 3.3 VDC 1200 mA TEN 6-4811N 5 VDC 1200 mA TEN 6-4812N 12 VDC 500 mA TEN 6-4813N 36 – 75 VDC 15 VDC 400 mA TEN 6-4815N 24 VDC 250 mA TEN 6-4821N ± 5 VDC ± 500 mA TEN 6-4822N ± 12 VDC ± 250 mA TEN 6-4823N ± 15 VDC ± 200 mA Dimensions Pin Single output Dual output 2 – Vin (GND) – Vin (GND) 3 – Vin (GND) – Vin (GND) 9 No pin Common 23 2 11 No con. – Vout 3 22 14 + Vout + Vout 16 – Vout Common 22 + Vin (Vcc) + Vin (Vcc) 16 9 23 + Vin (Vcc) + Vin (Vcc) 14 11 2.4 15.24 (0.6) (0.1) 4.1 10.2 20.3 (0.18) (0.4) (0.8) () = Inches 60 31.8 (1.25) 4.5 22.86 (0.9) (0.18) 15.24 5.08 2.54 (0.2) (0.6) (0.1) Bottom view www.tracopower.com High Performance DC/DC Converters CB TEN-6WIN Series 6 W Scheme UL 60950-1 Ultra wide 4:1 Input Range Operating temperature range –40 °C to +85 °C I/O isolation 1’500 VDC Input filter to meet EN 55022, class A Industry standard pinout Specifications Models 1) Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation single output: 1.2 % max. TEN 6-2410WIN 3.3 VDC 1200 mA dual output: 2% max. TEN 6-2411WIN 5 VDC 1200 mA Ripple & noise <80 mVpk-pk (20 MHz BW) TEN 6-2412WIN 12 VDC 500 mA Conducted EMI EN 55022, class EN55022 class A (internal filter) TEN 6-2413WIN 9 – 36 VDC 15 VDC 400 mA Short circuit protection continuous, automatic recovery TEN 6-2415WIN 24 VDC 250 mA Efficiency 84 % typ. TEN 6-2421WIN ± 5 VDC ± 500 mA 3.3 VDC models 77 % typ. TEN 6-2422WIN ± 12 VDC ± 250 mA Operating temperature –40 °C to +85 °C TEN 6-2423WIN ± 15 VDC ± 200 mA range 3.3 & 5.0 VDC models, above 60°C derating 2.5 %/K TEN 6-4810WIN 3.3 VDC 1200 mA other models, above 70°C derating 3.3 %/K TEN 6-4811WIN 5 VDC 1200 mA I/O isolation voltage 1500 VDC TEN 6-4812WIN 12 VDC 500 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report TEN 6-4813WIN 18 – 75 VDC 15 VDC 400 mA approvals TEN 6-4815WIN 24 VDC 250 mA Casing plastic (UL 94 V-O rated) TEN 6-4821WIN ± 5 VDC ± 500 mA Full datasheet www.tracopower.com/products/ten6win.pdf TEN 6-4822WIN ± 12 VDC ± 250 mA TEN 6-4823WIN ± 15 VDC ± 200 mA Dimensions Pin Single output Dual output 2 – Vin (GND) – Vin (GND) 3 – Vin (GND) – Vin (GND) 23 2 9 No pin Common 22 3 11 No con. – Vout 14 + Vout + Vout 16 – Vout Common 22 + Vin (Vcc) + Vin (Vcc) 16 9 23 + Vin (Vcc) + Vin (Vcc) 14 11 2.4 15.24 (0.6) (0.1) 4.1 10.2 20.3 (0.18) (0.4) (0.8) () = Inches 61 31.8 (1.25) 4.5 22.86 (0.18) (0.9) 15.24 5.08 2.54 (0.2) (0.6) (0.1) Bottom view www.tracopower.com DC/DC Converters High Performance CB TEN-6WIN-HI Series 6 W Scheme UL 60950-1 Ultra wide 4:1 Input Range Operating temperature range –40 °C to +85 °C I/O isolation 3’000 VDC Input filter to meet EN 55022, class A Industry standard pinout Specifications Models 1) Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation 1.2 % typ. TEN 6-2410WIN-HI 3.3 VDC 1200 mA Ripple & noise <80 mVpk-pk (20 MHz BW) TEN 6-2411WIN-HI 5 VDC 1200 mA Conducted EMI EN 55022, class EN55022 class A (internal filter) TEN 6-2412WIN-HI 12 VDC 500 mA Short circuit protection continuous, automatic recovery TEN 6-2413WIN-HI 9 – 36 VDC 15 VDC 400 mA TEN 6-2415WIN-HI 24 VDC 250 mA Efficiency 84 % typ. 3.3 VDC models 77 % typ. TEN 6-2421WIN-HI ± 5 VDC ± 500 mA Operating temperature –40 °C to +85 °C TEN 6-2422WIN-HI ± 12 VDC ± 250 mA range 3.3 & 5.0 VDC models, above 60°C derating 2.5 %/K TEN 6-2423WIN-HI ± 15 VDC ± 200 mA other models, above 70°C derating 3.3 %/K TEN 6-4810WIN-HI 3.3 VDC 1200 mA I/O isolation voltage 3000 VDC functional insulation TEN 6-4811WIN-HI 5 VDC 1200 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report TEN 6-4812WIN-HI 12 VDC 500 mA approvals TEN 6-4813WIN-HI 18 – 75 VDC 15 VDC 400 mA Casing plastic (UL 94 V-O rated) TEN 6-4815WIN-HI 24 VDC 250 mA TEN 6-4821WIN-HI ± 5 VDC ± 500 mA Full datasheet www.tracopower.com/products/ten6win.pdf TEN 6-4822WIN-HI ± 12 VDC ± 250 mA TEN 6-4823WIN-HI ± 15 VDC ± 200 mA Dimensions Pin Single output Dual output 2 – Vin (GND) – Vin (GND) 3 – Vin (GND) – Vin (GND) 9 No pin Common 23 2 11 No con. – Vout 3 22 14 + Vout + Vout 16 – Vout Common 22 + Vin (Vcc) + Vin (Vcc) 16 9 23 + Vin (Vcc) + Vin (Vcc) 14 11 2.4 15.24 (0.6) (0.1) 4.1 10.2 20.3 (0.18) (0.4) (0.8) () = Inches 62 31.8 (1.25) 4.5 22.86 (0.9) (0.18) 15.24 5.08 2.54 (0.2) (0.6) (0.1) Bottom view www.tracopower.com High Performance DC/DC Converters TEN-8 Series 8 W UL 60950-1 Wide 2:1 input range Operating temperature range –40 °C to +85 °C I/O isolation 1500 VDC Input filter to meet EN 55022, class A Remote On/Off Industry standard pinout Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2% max. max. Load regulation 1.0 % max. TEN 8-1210 3.3 VDC 2000 mA Ripple & noise <50 mVpk-pk (20 MHz BW) TEN 8-1211 5 VDC 1500 mA Conducted EMI EN 55022, class EN55022 class A (internal filter) TEN 8-1212 12 VDC 665 mA Short circuit protection continuous, automatic recovery TEN 8-1213 9 – 18 VDC 15 VDC 535 mA TEN 8-1221 ± 5 VDC ± 800 mA Efficiency 83 % typ. TEN 8-1222 ± 12 VDC ± 335 mA Operating temperature –40 °C to +85 °C range above 70°C derating 3.3 %/K TEN 8-1223 ± 15 VDC ± 265 mA TEN 8-2410 3.3 VDC 2000 mA I/O isolation voltage 1500 VDC (60 sec.) TEN 8-2411 5 VDC 1500 mA Safety standards / cUL /UL 60950-1, IEC/EN 60950-1 TEN 8-2412 12 VDC 665 mA approvals TEN 8-2413 18 – 36 VDC 15 VDC 535 mA Remote On/Off shutdown input for low input current (2.5 mA) TEN 8-2421 ± 5 VDC ± 800 mA in standby operation TEN 8-2422 ± 12 VDC ± 335 mA Casing metal, with insulated baseplate TEN 8-2423 ± 15 VDC ± 265 mA Full datasheet www.tracopower.com/products/ten8.pdf TEN 8-4810 3.3 VDC 2000 mA TEN 8-4811 5 VDC 1500 mA TEN 8-4812 12 VDC 665 mA TEN 8-4813 36 – 75 VDC 15 VDC 535 mA TEN 8-4821 ± 5 VDC ± 800 mA TEN 8-4822 ± 12 VDC ± 335 mA TEN 8-4823 ± 15 VDC ± 265 mA Dimensions Pin Single output Dual output 1 Remote On/Off Remote On/Off 2 – Vin (GND) – Vin (GND) 3 – Vin (GND) – Vin (GND) 1 2 23 9 No con. Common 22 3 11 No con. – Vout 14 + Vout + Vout 16 – Vout Common 16 9 22 + Vin (Vcc) + Vin (Vcc) 14 11 23 + Vin (Vcc) + Vin (Vcc) 2.4 15 .24 Insulated Baseplate (0.6) (0.1) 10.2 3.8 20.3 (0.15) (0.4) (0.8) () = Inches 63 32 (1.25) 25.4 2.0 (1.0) (0.08) 5.08 15.24 2.54 2.54 (0.2) (0.6) (0.1) (0.1) Bottom view www.tracopower.com DC/DC Converters High Performance TEN-8WI Series 8 W UL 60950-1 Ultra wide 4:1 input range and high input voltage up to 160VDC Certified for railway applications EN 50155 Operating temperature range –40°C to +85°C Input under voltage lockout I/O isolation 1500VDC Remote On/Off Industry standard pinout Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2% max. max. Load regulation – Single output models: 0.5 % max. TEN 8-2410WI 3.3 VDC 2400 mA – Dual output models: 1.0 % max. TEN 8-2411WI 5 VDC 1600 mA Ripple & Noise <50 mVpk-pk (20 MHz BW) TEN 8-2412WI 12 VDC 666 mA <75 mVp-p (20 MHz BW) for 43-160 VDC input models TEN 8-2413WI 9 – 36 VDC 15 VDC 533 mA EMC - Conducted noise: EN 55022, class EN55022 class A TEN 8-2421WI ± 5 VDC ± 800 mA (with external capacitor) TEN 8-2422WI ± 12 VDC ± 333 mA - Immunity: EN 50155 TEN 8-2423WI ± 15 VDC ± 267 mA Short circuit protection continuous, automatic recovery TEN 8-4810WI 3.3 VDC 2400 mA Efficiency 86 % typ. TEN 8-4811WI 5 VDC 1600 mA Operating temperature –40 °C to +85 °C TEN 8-4812WI 12 VDC 666 mA range above 80 °C derating 4.0 %/K TEN 8-4813WI 18 – 75 VDC 15 VDC 533 mA I/O isolation voltage 1500 VDC (60 sec.) TEN 8-4821WI ± 5 VDC ± 800 mA Safety standards / cUL /UL 60950-1, IEC/EN 60950-1, EN 50155 TEN 8-4822WI ± 12 VDC ± 333 mA approvals TEN 8-4823WI ± 15 VDC ± 267 mA Thermal shock and EN 61373 / MIL-STD-810F TEN 8-7210WI 3.3 VDC 2400 mA shock & vibration TEN 8-7211WI 5 VDC 1600 mA Remote On/Off shutdown input for low input current (2.5 mA) TEN 8-7212WI 12 VDC 666 mA in standby operation TEN 8-7213WI 43 – 160 VDC 15 VDC 533 mA Casing metal, with insulated baseplate TEN 8-7221WI ± 5 VDC ± 800 mA Full datasheet www.tracopower.com/products/ten8wi.pdf TEN 8-7222WI ± 12 VDC ± 333 mA TEN 8-7223WI ± 15 VDC ± 267 mA Dimensions Pin Single output Dual output 1 Remote On/Off Remote On/Off 2 – Vin (GND) – Vin (GND) 3 – Vin (GND) – Vin (GND) 1 9 No con. Common 2 23 22 3 11 No con. – Vout 14 + Vout + Vout 16 – Vout Common 22 + Vin (Vcc) + Vin (Vcc) 16 9 23 + Vin (Vcc) + Vin (Vcc) 14 11 2.4 15 .24 Insulated Baseplate (0.1) (0.6) 10.2 3.8 20.3 (0.15) (0.4) (0.8) () = Inches 64 32 (1.25) 25.4 2.0 (1.0) (0.08) 2.54 5.08 15.24 2.54 (0.2) (0.6) (0.1) (0.1) Bottom view www.tracopower.com High Performance DC/DC Converters THD-10N Series 10 W UL 60950-1 Wide 2:1 input range High efficiency up to 87% Operating temperature range –40°C to +85°C Internal EMI-filter meets EN 55022, class A I/O isolation 1500VDC Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 1 % max. max. Load regulation 1.2 % typ. THD 10-1210N 3.3 VDC 2700 mA Ripple & noise 100 mVpk-pk typ. (20 MHz BW) THD 10-1211N 5.1 VDC 2000 mA Conducted EMI EN 55022, class EN55022 class A (internal filter) THD 10-1212N 9 – 18 VDC 12 VDC 833 mA Short circuit protection continuous, automatic recovery THD 10-1213N 15 VDC 666 mA THD 10-1222N ± 12 VDC ± 416 mA Efficiency 86 % typ. THD 10-1223N ± 15 VDC ± 333 mA Operating temperature –40 °C to +85 °C range above 70°C derating 2.5 %/K THD 10-2410N 3.3 VDC 2700 mA THD 10-2411N 5.1 VDC 2000 mA I/O isolation voltage 1500 VDC THD 10-2412N 18 – 36 VDC 12 VDC 833 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, (report pending) THD 10-2413N 15 VDC 666 mA approvals THD 10-2422N ± 12 VDC ± 416 mA Casing metal THD 10-2423N ± 15 VDC ± 333 mA Full datasheet www.tracopower.com/products/thd10n.pdf THD 10-4810N 3.3 VDC 2700 mA THD 10-4811N 5.1 VDC 2000 mA THD 10-4812N 36 – 75 VDC 12 VDC 833 mA THD 10-4813N 15 VDC 666 mA THD 10-4822N ± 12 VDC ± 416 mA THD 10-4823N ± 15 VDC ± 333 mA Dimensions Pin Single output Dual output 1 Remote On/Off Remote On/Off 2 – Vin (GND) – Vin (GND) 3 – Vin (GND) – Vin (GND) 1 23 2 9 No con. Common 3 22 11 No con. – Vout 14 + Vout + Vout 16 – Vout Common 9 16 22 + Vin (Vcc) + Vin (Vcc) 14 11 23 + Vin (Vcc) + Vin (Vcc) 2.4 15 .24 Insulated Baseplate (0.6) (0.1) 3.8 10.2 20.3 (0.15) (0.4) (0.8) () = Inches 65 NEW Product 32 (1.25) 25.4 2.0 (1.0) (0.08) 15.24 2.54 5.08 2.54 (0.2) (0.6) (0.1) (0.1) Bottom view www.tracopower.com DC/DC Converters High Performance THD-10WIN Series 10 W UL 60950-1 Ultra wide 4:1 input range High efficiency up to 87% Operating temperature range –40°C to +85°C Internal EMI-filter meets EN 55022, class A No minimum load required I/O isolation 1500VDC Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 1 % max. max. Load regulation 1.2 % typ. THD 10-2410WIN 3.3 VDC 2700 mA Ripple & noise <100 mVpk-pk (20 MHz BW) THD 10-2411WIN 5.1 VDC 2000 mA Conducted EMI EN 55022, class EN55022 class A (internal filter) THD 10-2412WIN 9 – 36 VDC 12 VDC 833 mA Short circuit protection continuous, automatic recovery THD 10-2413WIN 15 VDC 666 mA THD 10-2415WIN 24 VDC 416 mA Efficiency 86 % typ. THD 10-2422WIN ± 12 VDC ± 416 mA Operating temperature –40 °C to +85 °C range above 70°C derating 2.5 %/K THD 10-2423WIN ± 15 VDC ± 333 mA THD 10-4810WIN 3.3 VDC 2700 mA I/O isolation voltage 1500 VDC THD 10-4811WIN 5.1 VDC 2000 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, (report pending) THD 10-4812WIN 18 – 75 VDC 12 VDC 833 mA approvals THD 10-4813WIN 15 VDC 666 mA Casing metal THD 10-4815WIN 24 VDC 416 mA Full datasheet www.tracopower.com/products/thd10win.pdf THD 10-4822WIN ± 12 VDC ± 416 mA THD 10-4823WIN ± 15 VDC ± 333 mA Dimensions Pin Single output Dual output 1 Remote On/Off Remote On/Off 2 – Vin (GND) – Vin (GND) 3 – Vin (GND) – Vin (GND) 1 23 2 9 No con. Common 22 3 11 No con. – Vout 14 + Vout + Vout 16 – Vout Common 22 + Vin (Vcc) + Vin (Vcc) 16 9 23 + Vin (Vcc) + Vin (Vcc) 11 14 2.4 15 .24 Insulated Baseplate (0.6) (0.1) 3.8 10.2 20.3 (0.15) (0.4) (0.8) () = Inches 66 NEW Product 32 (1.25) 25.4 2.0 (1.0) (0.08) 15.24 2.54 5.08 2.54 (0.2) (0.1) (0.1) (0.6) Bottom view www.tracopower.com High Performance DC/DC Converters C CBB THL-10 Series 10 W Schem Schemee UL 60950-1 1“ x 1“ x 0.4“ metal package Wide 2:1 input voltage range High efficiency up to 87 % I/O-isolation 1500 VDC Input filter to meet EN 55022, class A No minimum load required Specifications Models Order code Input voltage Output voltage Output current Line regulation 1% max. max. Load regulation – Single output models: 0.5% max. THL 10-1210 3.3 VDC 2500 mA – Dual output models: 1.0 % max. THL 10-1211 5.1 VDC 2000 mA Ripple & noise 100 mVpk-pk typ. (20 MHz BW) THL 10-1212 12 VDC 830 mA Conducted EMI EN 55022, class EN55022 class A (internal filter) THL 10-1213 9 – 18 VDC 15 VDC 670 mA Short circuit protection continuous, automatic recovery THL 10-1221 ± 5 VDC ± 1000 mA Efficiency 84 % typ. THL 10-1222 ± 12 VDC ± 416 mA Operating temperature –40 °C to +80 °C THL 10-1223 ± 15 VDC ± 333 mA range above 60°C derating 2.5 %/K THL 10-2410 3.3 VDC 2500 mA - optional heatsink for extended temp.: see datasheet THL 10-2411 5.1 VDC 2000 mA I/O isolation voltage 1500 VDC (60 sec.) THL 10-2412 12 VDC 830 mA Safety standards/ cUL/UL 60950-1, IEC/EN 60950-1, CB-report THL 10-2413 18 – 36VDC 15 VDC 670 mA approvals THL 10-2421 ± 5 VDC ± 1000 mA Casing metal, with insulated baseplate THL 10-2422 ± 12 VDC ± 416 mA THL 10-2423 ± 15 VDC ± 333 mA Full datasheet www.tracopower.com/products/thl10.pdf THL 10-4810 3.3 VDC 2500 mA THL 10-4811 5.1 VDC 2000 mA THL 10-4812 12 VDC 830 mA THL 10-4813 36 – 75 VDC 15 VDC 670 mA THL 10-4821 ± 5 VDC ± 1000 mA THL 10-4822 ± 12 VDC ± 416 mA THL 10-4823 ± 15 VDC ± 333 mA Optional heatsink: THL-HS1 Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 5.08 2 – Vin (GND) – Vin (GND) (0.2) 3 + Vout + Vout 4 No pin Common 2 1 5 – Vout – Vout Bottom view 5 4 3 10.2 2.5 10.16 10.16 6.0 (0.1) (0.4) (0.4) (0.24) (0.4) 25.4 (1.0) () = Inches 67 NEW Product 20.32 (0.8) 2.5 (0.1) 25.4 (1.0) www.tracopower.com DC/DC Converters High Performance CB CB THL-10WI Series 10 W Schem Schemee UL 60950-1 1“ x 1“ x 0.4“ metal package Ultra wide 4:1 input voltage range High efficiency up to 87 % I/O-isolation 1500 VDC Input filter to meet EN 55022, class A Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 1% max. max. Load regulation – Single output models: 1.0% max. THL 10-2410WI 3.3 VDC 2200 mA – Dual output models: 2.0 % max. THL 10-2411WI 5.1 VDC 2000 mA Ripple & noise <100 mVpk-pk (20 MHz BW) THL 10-2412WI 12 VDC 830 mA Conducted EMI EN 55022, class EN55022 class A (internal filter) THL 10-2413WI 9 – 36 VDC 15 VDC 660 mA Short circuit protection continuous, automatic recovery THL 10-2415WI 24 VDC 410 mA Efficiency 86 % typ. THL 10-2421WI ± 5 VDC ± 1000 mA Operating temperature –40 °C to +75 °C THL 10-2422WI ± 12 VDC ± 410 mA range above 60°C derating 2.5 %/K THL 10-2423WI ± 15 VDC ± 330 mA - optional heatsink for extended temp.: see datasheet THL 10-4810WI 3.3 VDC 2200 mA I/O isolation voltage 1500 VDC (60 sec.) THL 10-4811WI 5.1 VDC 2000 mA Safety standards/ cUL/UL 60950-1, IEC/EN 60950-1 CB-report THL 10-4812WI 12 VDC 830 mA approvals THL 10-4813WI 18 – 75 VDC 15 VDC 660 mA Remote On/Off shutdown input for low current (10 mA) THL 10-4815WI 24 VDC 410 mA in standby operation THL 10-4821WI ± 5 VDC ± 1000 mA Casing metal, with insulated baseplate THL 10-4822WI ± 12 VDC ± 410 mA THL 10-4823WI ± 15 VDC ± 330 mA Full datasheet www.tracopower.com/products/thl10wi.pdf Optional heatsink: THL-HS1 Dimensions Pin Single output Dual output 7.62 5.08 1 + Vin (Vcc) + Vin (Vcc) (0.2) (0.3) 2 – Vin (GND) – Vin (GND) 3 + Vout + Vout 2 1 6 4 No pin Common Bottom view 5 – Vout – Vout 6 Remote On/Off Remote On/Off 4 3 5 2.5 10.16 10.16 6.0 10.2 (0.1) (0.4) (0.4) (0.24) (0.4) 25.4 (1.0) () = Inches 68 20.32 (0.8) 2.5 (0.1) 25.4 (1.0) www.tracopower.com High Performance DC/DC Converters THD-12 Series 12 W UL 60950-1 DIP-24 metal package Wide 2:1 input range I/O isolation 1500 VDC Operating temperature range –40°C to + 85°C Input under voltage lockout Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5% max. max. Load regulation – Single output models: 0.5 % max. THD 12-1209 2.5 VDC 3500 mA – Dual output models: 1.0 % max. THD 12-1210 3.3 VDC 3500 mA Ripple & noise <85 mVpk-pk (20 MHz BW) THD 12-1211 9 – 18 VDC 5.1 VDC 2400 mA Conducted EMI EN 55022, class EN55022 class A (with external capacitor) THD 12-1212 12 VDC 1000 mA Short circuit protection continuous, automatic recovery THD 12-1222 ± 12 VDC ± 500 mA Efficiency 86 % typ. THD 12-1223 ± 15 VDC ± 400 mA Operating temperature –40 °C to +85°C THD 12-2409 2.5 VDC 3500 mA range above 65 °C derating 2.5 %/K THD 12-2410 3.3 VDC 3500 mA THD 12-2411 18 – 36 VDC 5.1 VDC 2400 mA I/O isolation voltage 1500 VDC (60 sec.) THD 12-2412 12 VDC 1000 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 / approvals THD 12-2422 ± 12 VDC ± 500 mA THD 12-2423 ± 15 VDC ± 400 mA Remote On/Off shutdown input for low current (2.5 mA) in standby operation THD 12-4809 2.5 VDC 3500 mA THD 12-4810 3.3 VDC 3500 mA Casing metal, with insulated baseplate THD 12-4811 36 – 75 VDC 5.1 VDC 2400 mA Full datasheet www.tracopower.com/products/thd12.pdf THD 12-4812 12 VDC 1000 mA THD 12-4822 ± 12 VDC ± 500 mA THD 12-4823 ± 15 VDC ± 400 mA Dimensions Pin Single output Dual output 1 Remote On/Off Remote On/Off 2 – Vin (GND) – Vin (GND) 3 – Vin (GND) – Vin (GND) 1 9 No con. Common 2 23 22 3 11 No con. – Vout 14 + Vout + Vout 16 – Vout Common 22 + Vin (Vcc) + Vin (Vcc) 16 9 23 + Vin (Vcc) + Vin (Vcc) 14 11 2.4 15 .24 Insulated Baseplate (0.6) (0.1) 3.8 10.2 20.3 (0.4) (0.15) (0.8) () = Inches 69 32 (1.25) 25.4 2.0 (1.0) (0.08) 5.08 15.24 2.54 2.54 (0.2) (0.6) (0.1) (0.1) Bottom view www.tracopower.com DC/DC Converters High Performance THD-12WI Series 12 W UL 60950-1 DIP-24 metal package Ultra wide 4:1 Input Range Operating temperature range –40 °C to +85 °C I/O isolation 1500 VDC Input under voltage lockout Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2% max. max. Load regulation – Single output models: 0.5 % max. THD 12-2410WI 3.3 VDC 3500 mA – Dual output models: 1.0 % max. THD 12-2411WI 5.1 VDC 2400 mA Ripple & noise <85 mVpk-pk (20 MHz BW) THD 12-2412WI 12 VDC 1000 mA Conducted EMI EN 55022, class EN55022 class A (with external capacitor) THD 12-2413WI 9 – 36 VDC 15 VDC 800 mA Short circuit protection continuous, automatic recovery THD 12-2421WI ± 5 VDC ± 1200 mA Efficiency 86 % typ. THD 12-2422WI ± 12 VDC ± 500 mA Operating temperature –40 °C to +85°C THD 12-2423WI ± 15 VDC ± 400 mA range above 65 °C derating 2.5 %/K THD 12-4810WI 3.3 VDC 3500 mA THD 12-4811WI 5.1 VDC 2400 mA I/O isolation voltage 1500 VDC (60 sec.) THD 12-4812WI 12 VDC 1000 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 / approvals THD 12-4813WI 18 – 75 VDC 15 VDC 800 mA THD 12-4821WI ± 5 VDC ± 1200 mA Remote On/Off shutdown input for low current (2.5 mA) in standby operation THD 12-4822WI ± 12 VDC ± 500 mA THD 12-4823WI ± 15 VDC ± 400 mA Casing metal, 5-side shielded with insulated baseplate Full datasheet www.tracopower.com/products/thd12wi.pdf Dimensions Pin Single output Dual output 1 Remote On/Off Remote On/Off 2 – Vin (GND) – Vin (GND) 3 – Vin (GND) – Vin (GND) 1 2 23 9 No con. Common 22 3 11 No con. – Vout 14 + Vout + Vout 16 – Vout Common 16 9 22 + Vin (Vcc) + Vin (Vcc) 14 11 23 + Vin (Vcc) + Vin (Vcc) 2.4 15 .24 Insulated Baseplate (0.6) (0.1) 3.8 10.2 20.3 (0.4) (0.15) (0.8) () = Inches 70 32 (1.25) 25.4 2.0 (1.0) (0.08) 2.54 5.08 15.24 2.54 (0.2) (0.6) (0.1) (0.1) Bottom view www.tracopower.com High Performance DC/DC Converters CB THD-15N Series 15 W Scheme UL 60950-1 Highest power density in DIP 24 metal package Wide 2:1 input range Very high efficiency up to 90 % Operating temperature range –40 °C to +85 °C I/O isolation 1500 VDC Input under voltage lockout Low input current at no load Input filter to meet EN 55022, class A Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5% max. max. Load regulation – Single output models: 0.5 % max. THD 15-1210N 3.3 VDC 4000 mA – Dual output models: 1.0 % max. THD 15-1211N 5.1 VDC 3000 mA Ripple & noise <60 mVpk-pk (20 MHz BW) THD 15-1212N 12 VDC 1250 mA Conducted EMI EN 55022, class EN55022 class A (internal filter) THD 15-1213N 9 – 18 VDC 15 VDC 1000 mA Short circuit protection continuous, automatic recovery THD 15-1221N ± 5 VDC ± 1500 mA Efficiency 88 % typ. THD 15-1222N ± 12 VDC ± 625 mA Operating temperature –40 °C to +85°C THD 15-1223N ± 15 VDC ± 500 mA range above 70 °C derating 4.0 %/K THD 15-2410N 3.3 VDC 4000 mA THD 15-2411N 5.1 VDC 3000 mA I/O isolation voltage 1500 VDC (60 sec.) THD 15-2412N 12 VDC 1250 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1, CB-report / approvals THD 15-2413N 18 – 36 VDC 15 VDC 1000 mA THD 15-2421N ± 5 VDC ± 1500 mA Remote On/Off shutdown input for low current (2.5 mA) in standby operation THD 15-2422N ± 12 VDC ± 625 mA THD 15-2423N ± 15 VDC ± 500 mA Casing metal, 6-side shielded with insulated baseplate THD 15-4810N 3.3 VDC 4000 mA Full datasheet www.tracopower.com/products/thd15n.pdf THD 15-4811N 5.1 VDC 3000 mA THD 15-4812N 12 VDC 1250 mA THD 15-4813N 36 – 75 VDC 15 VDC 1000 mA THD 15-4821N ± 5 VDC ± 1500 mA THD 15-4822N ± 12 VDC ± 625 mA THD 15-4823N ± 15 VDC ± 500 mA Dimensions Pin Single output Dual output 1 Remote On/Off Remote On/Off 2 – Vin (GND) – Vin (GND) 1 3 – Vin (GND) – Vin (GND) 2 23 9 No con. Common 22 3 11 No con. – Vout 14 + Vout + Vout 16 – Vout Common 16 9 22 + Vin (Vcc) + Vin (Vcc) 14 11 23 + Vin (Vcc) + Vin (Vcc) 2.4 15.24 Insulated Baseplate (0.6) (0.1) 10.2 3.8 20.3 (0.15) (0.4) (0.8) () = Inches 71 32 (1.25) 25.4 2.0 (1.0) (0.08) 5.08 15.24 2.54 2.54 (0.2) (0.6) (0.1) (0.1) Bottom view www.tracopower.com DC/DC Converters High Performance CB THD-15WIN Series 15 W Scheme UL 60950-1 Highest power density in DIP 24 metal package Ultra wide 4:1 input range Very high efficiency up to 90 % Operating temperature range –40 °C to +85 °C I/O isolation 1500 VDC Input under voltage lockout Low input current at no load Input filter to meet EN 55022, class A Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5% max. max. Load regulation – Single output models: 0.5 % max. THD 15-2410WIN 3.3 VDC 4000 mA – Dual output models: 1.0 % max. THD 15-2411WIN 5.1 VDC 3000 mA Ripple & noise <60 mVpk-pk (20 MHz BW) THD 15-2412WIN 12 VDC 1250 mA Conducted EMI EN 55022, class EN55022 class A (internal filter) THD 15-2413WIN 9 – 36 VDC 15 VDC 1000 mA Short circuit protection continuous, automatic recovery THD 15-2421WIN ± 5 VDC ± 1500 mA Efficiency 88 % typ. THD 15-2422WIN ± 12 VDC ± 625 mA Operating temperature –40 °C to +85°C THD 15-2423WIN ± 15 VDC ± 500 mA range above 70 °C derating 4.0 %/K THD 15-4810WIN 3.3 VDC 4000 mA THD 15-4811WIN 5.1 VDC 3000 mA I/O isolation voltage 1500 VDC (60 sec.) THD 15-4812WIN 12 VDC 1250 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1, CB-report / approvals THD 15-4813WIN 18 – 75 VDC 15 VDC 1000 mA THD 15-4821WIN ± 5 VDC ± 1500 mA Remote On/Off shutdown input for low current (2.5 mA) in standby operation THD 15-4822WIN ± 12 VDC ± 625 mA THD 15-4823WIN ± 15 VDC ± 500 mA Casing metal, 6-side shielded with insulated baseplate Full datasheet www.tracopower.com/products/thd15win.pdf Dimensions Pin Single output Dual output 1 Remote On/Off Remote On/Off 2 – Vin (GND) – Vin (GND) 1 3 – Vin (GND) – Vin (GND) 2 23 9 No con. Common 22 3 11 No con. – Vout 14 + Vout + Vout 16 – Vout Common 16 9 22 + Vin (Vcc) + Vin (Vcc) 14 11 23 + Vin (Vcc) + Vin (Vcc) 2.4 15.24 Insulated Baseplate (0.6) (0.1) 10.2 3.8 20.3 (0.15) (0.4) (0.8) () = Inches 72 32 (1.25) 25.4 2.0 (1.0) (0.08) 2.54 5.08 15.24 2.54 (0.2) (0.6) (0.1) (0.1) Bottom view www.tracopower.com High Performance DC/DC Converters CB CB TEL-15 Series 15 W Schem Schemee UL 60950-1 Wide 2:1 input range I/O isolation 1500 VDC Cost optimized design Specifications Models Order code Input voltage Output voltage Output current Line regulation 1.0 % max. max. Load regulation – Single output models: 0.5 % max. TEL 15-1210 3.3 VDC 3000 mA – Dual output models: 2.0 % max. TEL 15-1211 5.1 VDC 3000 mA Ripple & noise <75 mVpk-pk (20 MHz BW) TEL 15-1212 9 – 18 VDC 12 VDC 1250 mA Input filter Pi-filter TEL 15-1213 15 VDC 1000 mA Short circuit protection continuous, automatic recovery TEL 15-1222 ± 12 VDC ± 625 mA Efficiency 86 % typ. TEL 15-1223 ± 15 VDC ± 500 mA Operating temperature –40 °C to +71 °C TEL 15-2410 3.3 VDC 3000 mA range above 60 °C derating 2.5 %/K TEL 15-2411 5.1 VDC 3000 mA - optional heatsink for extended temp.: see datasheet TEL 15-2412 18 – 36 VDC 12 VDC 1250 mA I/O isolation voltage 1500 VDC (60 sec.) TEL 15-2413 15 VDC 1000 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report TEL 15-2422 ± 12 VDC ± 625 mA approvals TEL 15-2423 ± 15 VDC ± 500 mA Casing metal, 6-side shielded with insulated baseplate TEL 15-4810 3.3 VDC 3000 mA TEL 15-4811 5.1 VDC 3000 mA Full datasheet www.tracopower.com/products/tel15.pdf TEL 15-4812 36 – 75 VDC 12 VDC 1250 mA TEL 15-4813 15 VDC 1000 mA TEL 15-4822 ± 12 VDC ± 625 mA TEL 15-4823 ± 15 VDC ± 500 mA Optional heatsink: TEN-HS4 Dimensions Pin Single output Dual output 5.08 7.62 1 + Vin (Vcc) + Vin (Vcc) (0.2) (0.3) 2 – Vin (GND) – Vin (GND) 3 + Vout + Vout 4 No pin Common 5 – Vout – Vout 21 Bottom view 54 3 10.16 10.16 2.5 (0.1) (0.4) (0.4) Insulated Baseplate 6 10.2 25.4 (0.24) (0.4) (1.0) () = Inches 73 50.8 (2.0) 15.2 20.32 (0.8) (0.6) www.tracopower.com DC/DC Converters High Performance CB THN-15 Series 15 W Scheme UL 60950-1 1“ x 1“ x 0.4“ metal package 6-side shielded metal casing Wide 2:1 input voltage range Operating temperature range –40 °C to +85 °C I/O isolation 1500 VDC Input under voltage lockout Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2% max. max. Load regulation – Single output models: 0.5% max. THN 15-1210 3.3 VDC 4000 mA – Dual output models: 1.0 % max. THN 15-1211 5.0 VDC 3000 mA Output voltage ±10 % by external resistor THN 15-1212 12 VDC 1300 mA adjustment THN 15-1213 9 – 18 VDC 15 VDC 1000 mA Ripple & noise <100 mVpk-pk (20 MHz BW) THN 15-1221 ± 5 VDC ± 1500 mA Conducted EMI EN 55022, class EN55022 class A (with external capacitor) THN 15-1222 ± 12 VDC ± 625 mA Short circuit protection continuous, automatic recovery THN 15-1223 ± 15 VDC ± 500 mA Efficiency 86 % typ. THN 15-2410 3.3 VDC 4000 mA THN 15-2411 5.0 VDC 3000 mA Operating temperature –40 °C to +85 °C range above 70 °C derating 2.8 %/K THN 15-2412 12 VDC 1300 mA I/O isolation voltage 1500 VDC (60 sec.) THN 15-2413 18 – 36 VDC 15 VDC 1000 mA THN 15-2421 ± 5 VDC ± 1500 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1, CB-report / approvals THN 15-2422 ± 12 VDC ± 625 mA THN 15-2423 ± 15 VDC ± 500 mA Remote On/Off shutdown input for low current (2.5 mA) in standby operation THN 15-4810 3.3 VDC 4000 mA THN 15-4811 5.0 VDC 3000 mA Casing metal, 6-side shielded with insulated baseplate THN 15-4812 12 VDC 1300 mA Full datasheet www.tracopower.com/products/thn15.pdf THN 15-4813 36 – 75 VDC 15 VDC 1000 mA THN 15-4821 ± 5 VDC ± 1500 mA THN 15-4822 ± 12 VDC ± 625 mA THN 15-4823 ± 15 VDC ± 500 mA Optional heatsink: THN-HS1 Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 7.62 5.08 2 – Vin (GND) – Vin (GND) (0.2) (0.3) 3 + Vout + Vout 4* Trim Common 2 1 6 5 – Vout – Vout 6* Remote On/Off Remote On/Off Bottom view * optional no pin on request 4 3 5 10.16 10.16 5.6 9.9 2.5 (0.22) (0.1) (0.4) (0.4) (0.39) 25.4 (1.0) () = Inches 74 20.32 (0.8) 2.5 (0.1) 25.4 (1.0) www.tracopower.com High Performance DC/DC Converters CB THN-15WI Series 15 W Scheme UL 60950-1 1“ x 1“ x 0.4“ metal package 6-side shielded metal casing Ultra wide 4:1 input voltage range Operating temperature range –40 °C to +85 °C I/O isolation 1500 VDC Input under voltage lockout Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5% max. max. Load regulation – Single output models: 0.2% max. THN 15-2410WI 3.3 VDC 4000 mA – Dual output models: 1.0 % max. THN 15-2411WI 5.0 VDC 3000 mA Output voltage ±10 % by external resistor THN 15-2412WI 12 VDC 1300 mA adjustment (single output models only) THN 15-2413WI 9 – 36 VDC 15 VDC 1000 mA Ripple & noise <100 mVpk-pk (20 MHz BW) THN 15-2421WI ± 5 VDC ± 1500 mA Conducted EMI EN 55022, class EN55022 class A (with external capacitor) THN 15-2422WI ± 12 VDC ± 625 mA Short circuit protection continuous, automatic recovery THN 15-2423WI ± 15 VDC ± 500 mA Efficiency 86 % typ. THN 15-4810WI 3.3 VDC 4000 mA THN 15-4811WI 5.0 VDC 3000 mA Operating temperature –40 °C to +85 °C range above 65 °C derating 2.5 %/K THN 15-4812WI 12 VDC 1300 mA I/O isolation voltage 1500 VDC (60 sec.) THN 15-4813WI 18 – 75 VDC 15 VDC 1000 mA THN 15-4821WI ± 5 VDC ± 1500 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1, CB-report / approvals THN 15-4822WI ± 12 VDC ± 625 mA THN 15-4823WI ± 15 VDC ± 500 mA Remote On/Off shutdown input for low current (2.5 mA) in standby operation Optional heatsink: THN-HS1 Casing metal, 6-side shielded with insulated baseplate Full datasheet www.tracopower.com/products/thn15wi.pdf Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 7.62 5.08 2 – Vin (GND) – Vin (GND) (0.2) (0.3) 3 + Vout + Vout 4* Trim Common 2 1 6 5 – Vout – Vout 6* Remote On/Off Remote On/Off Bottom view * optional no pin on request 5 4 3 5.6 9.9 2.5 10.16 10.16 (0.22) (0.1) (0.4) (0.4) (0.39) 25.4 (1.0) () = Inches 75 20.32 (0.8) 2.5 (0.1) 25.4 (1.0) www.tracopower.com DC/DC Converters High Performance CB THN-20 Series 20 W Scheme UL 60950-1 1“ x 1“ x 0.4“ metal package 6-side shielded metal casing Wide 2:1 input voltage range Very high efficiency up to 91 % Operating temperature range –40 °C to +75 °C I/O isolation 1500 VDC Input undervoltage-lockout Low input current at no load Input filter to meet EN 55022, class A Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5% max. max. Load regulation – Single output models: 0.2% max. THN 20-1210 3.3 VDC 4500 mA – Dual output models: 1.0 % max. THN 20-1211 5.0 VDC 4000 mA Output voltage ±10 % by external resistor THN 20-1212 9 – 18 VDC 12 VDC 1670 mA adjustment THN 20-1213 15 VDC 1330 mA Ripple & noise <100 mVpk-pk (20 MHz BW) THN 20-1222 ± 12 VDC ± 833 mA Conducted EMI EN 55022, class EN55022 class A (internal filter) THN 20-1223 ± 15 VDC ± 667 mA Short circuit protection continuous, automatic recovery THN 20-2410 3.3 VDC 4500 mA Efficiency 89 % typ. THN 20-2411 5.0 VDC 4000 mA THN 20-2412 18 – 36 VDC 12 VDC 1670 mA Operating temperature –40 °C to +75 °C range above 60°C derating 3.0 %/K THN 20-2413 15 VDC 1330 mA I/O isolation voltage 1500 VDC (60 sec.) THN 20-2422 ± 12 VDC ± 833 mA THN 20-2423 ± 15 VDC ± 667 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 CB-report THN 20-4810 3.3 VDC 4500 mA Remote On/Off shutdown input for low current (1.5 mA) THN 20-4811 5.0 VDC 4000 mA in standby operation THN 20-4812 36 – 75 VDC 12 VDC 1670 mA Casing metal, 6-side shielded with insulated baseplate THN 20-4813 15 VDC 1330 mA Full datasheet www.tracopower.com/products/thn20.pdf THN 20-4822 ± 12 VDC ± 833 mA THN 20-4823 ± 15 VDC ± 667 mA Optional heatsink: THN-HS1 Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 7.62 5.08 2 – Vin (GND) – Vin (GND) (0.2) 3 + Vout + Vout (0.3) 4* Trim Common 1 5 – Vout – Vout 2 6 6* Remote On/Off Remote On/Off Bottom view * optional no pin on request 5 4 3 2.5 10.16 10.16 5.6 9.9 (0.1) (0.4) (0.4) (0.22) (0.39) 25.4 (1.0) () = Inches 76 20.32 (0.8) 2.5 (0.1) 25.4 (1.0) www.tracopower.com High Performance DC/DC Converters CB THN-20WI Series 20 W Scheme UL 60950-1 1“ x 1“ x 0.4“ metal package 6-side shielded metal casing Ultra wide 4:1 input voltage range Very high efficiency up to 91 % Operating temperature range –40 °C to +75 °C I/O isolation 1500 VDC Input undervoltage-lockout Low input current at no load Input filter to meet EN 55022, class A Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5% max. max. Load regulation – Single output models: 0.2% max. THN 20-2410WI 3.3 VDC 4500 mA – Dual output models: 1.0 % max. THN 20-2411WI 5.0 VDC 4000 mA Output voltage ±10 % by external resistor THN 20-2412WI 9 – 36 VDC 12 VDC 1670 mA adjustment THN 20-2413WI 15 VDC 1330 mA Ripple & noise <100 mVpk-pk (20 MHz BW) THN 20-2422WI ± 12 VDC ± 833 mA Conducted EMI EN 55022, class EN55022 class A (internal filter) THN 20-2423WI ± 15 VDC ± 667 mA Short circuit protection continuous, automatic recovery THN 20-4810WI 3.3 VDC 4500 mA Efficiency 89 % typ. THN 20-4811WI 5.0 VDC 4000 mA THN 20-4812WI 18 – 75 VDC 12 VDC 1670 mA Operating temperature –40 °C to +75 °C range above 60 °C derating 3.0 %/K THN 20-4813WI 15 VDC 1330 mA I/O isolation voltage 1500 VDC (60 sec.) THN 20-4822WI ± 12 VDC ± 833 mA THN 20-4823WI ± 15 VDC ± 667 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 CB-report Remote On/Off shutdown input for low current (1.5 mA) Optional heatsink: THN-HS1 in standby operation Casing metal, 6-side shielded with insulated baseplate Full datasheet www.tracopower.com/products/thn20wi.pdf Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 7.62 5.08 2 – Vin (GND) – Vin (GND) (0.2) 3 + Vout + Vout (0.3) Trim Common 4* 1 5 – Vout – Vout 2 6 6 Remote On/Off Remote On/Off * Bottom view * optional no pin on request 5 4 3 2.5 10.16 10.16 5.6 9.9 (0.1) (0.4) (0.4) (0.22) (0.39) 25.4 (1.0) () = Inches 77 20.32 (0.8) 2.5 (0.1) 25.4 (1.0) www.tracopower.com DC/DC Converters High Performance CB CB THL-20WI Series 20 W Schem Schemee UL 60950-1 1“ x 1“ x 0.4“ metal package Ultra wide 4:1 input voltage range I/O isolation 1500 VDC Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output voltage Output current Line regulation 1% max. max. Load regulation – Single output models: 1.0% max. THL 20-2410WI 3.3 VDC 4500 mA – Dual output models: 2.0 % max. THL 20-2411WI 5.1 VDC 4000 mA Output voltage ±10 % by external resistor (single output models) THL 20-2412WI 12 VDC 1670 mA adjustment THL 20-2413WI 9 – 36 VDC 15 VDC 1340 mA Ripple & noise <100 mVpk-pk (20 MHz BW) THL 20-2415WI 24 VDC 835 mA Short circuit protection continuous, automatic recovery THL 20-2422WI ± 12 VDC ± 835 mA Efficiency 88% typ. THL 20-2423WI ± 15 VDC ± 670 mA Operating temperature –40 °C to +75 °C THL 20-4810WI 3.3 VDC 4500 mA range above 60°C derating 2.2 %/K THL 20-4811WI 5.1 VDC 4000 mA - optional heatsink for extended temp.: see datasheet THL 20-4812WI 12 VDC 1670 mA I/O isolation voltage 1500 VDC (60 sec.) THL 20-4813WI 18 – 75 VDC 15 VDC 1340 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 CB-report THL 20-4815WI 24 VDC 835 mA Remote On/Off shutdown input for low current THL 20-4822WI ± 12 VDC ± 835 mA in standby operation THL 20-4823WI ± 15 VDC ± 670 mA Casing metal, with insulated baseplate Optional heatsink: THL-HS1 Full datasheet www.tracopower.com/products/thl20wi.pdf Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 7.62 5.08 2 – Vin (GND) – Vin (GND) (0.2) (0.3) 3 + Vout + Vout 4 Trim Common 1 6 2 5 – Vout – Vout 6 Remote On/Off Remote On/Off Bottom view 4 5 3 10.16 10.16 6.0 10.2 2.5 (0.4) (0.4) (0.24) (0.1) (0.4) 25.4 (1.0) () = Inches 78 20.32 (0.8) 2.5 (0.1) 25.4 (1.0) www.tracopower.com High Performance DC/DC Converters CB TEN-20 Series 20 W Scheme UL 60950-1 2“ x 1“ x 0.4“ metal package Wide 2:1 input range Operating temperature range –40 °C to +85 °C I/O isolation 1500 VDC Input filter to meet EN 55022 class A Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.3% max. max. Load regulation – Single output models: 0.5 % max. TEN 20-1210 3.3 VDC 4000 mA – Dual output models: 1.0 % max. TEN 20-1211 5 VDC 4000 mA Ripple & noise <80 mVpk-pk (20 MHz BW) TEN 20-1212 9 – 18 VDC 12 VDC 1670 mA Conducted EMI EN 55022, class EN55022 class A (internal filter) TEN 20-1213 15 VDC 1340 mA Short circuit protection continuous, automatic recovery TEN 20-1222 ± 12 VDC ± 835 mA Efficiency 85 % typ. TEN 20-1223 ± 15 VDC ±670 mA Operating temperature –40 °C to +85 °C TEN 20-2410 3.3 VDC 4000 mA range above 60 °C derating 2.5 %/K TEN 20-2411 5 VDC 4000 mA TEN 20-2412 18 – 36 VDC 12 VDC 1670 mA I/O isolation voltage 1500 VDC (60 sec.) TEN 20-2413 15 VDC 1340 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 TEN 20-2422 ± 12 VDC ± 835 mA / approvals TEN 20-2423 ± 15 VDC ±670 mA Remote On/Off shutdown input for low input current (5 mA) in standby operation TEN 20-4810 3.3 VDC 4000 mA TEN 20-4811 5 VDC 4000 mA Casing metal, 6-side shielded with insulated baseplate TEN 20-4812 36 – 75 VDC 12 VDC 1670 mA Full datasheet www.tracopower.com/products/ten20.pdf TEN 20-4813 15 VDC 1340 mA TEN 20-4822 ± 12 VDC ± 835 mA TEN 20-4823 ± 15 VDC ±670 mA Optional heatsink: TEN-HS4 Dimensions Pin Single output Dual output 7.62 7.62 1 + Vin (Vcc) + Vin (Vcc) (0.3) (0.3) 2 – Vin (GND) – Vin (GND) 3 + Vout + Vout 5.08 (0.2) 4 No pin Common 5 – Vout – Vout 6 21 6 * Remote On/Off Remote On/Off Bottom view * optional no pin on request 54 3 10.16 10.16 2.5 (0.4) (0.4) (0.1) Insulated Baseplate 6 10.2 25.4 (0.24) (0.4) (1.0) () = Inches 79 50.8 (2.0) 20.32 15.2 (0.8) (0.6) www.tracopower.com DC/DC Converters High Performance TEN-20WIN Series 20 W UL 60950-1 2“ x 1“ x 0.4“ metal package Ultra wide 4:1 input voltage range Operating temperature range –40 °C to +85 °C I/O isolation 1500 VDC Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2% max. max. Load regulation – Single output models: 0.5 % max. TEN 20-2410WIN 3.3 VDC 5500 mA – Dual output models: 1.0 % max. TEN 20-2411WIN 5 VDC 4000 mA Output voltage Single output models only: ±10 % (by external resistor) TEN 20-2412WIN 12 VDC 1670 mA adjustment TEN 20-2413WIN 9 – 36 VDC 15 VDC 1330 mA Ripple & noise – Single output models: <75 mVpk-pk (20 MHz BW) TEN 20-2421WIN ± 5 VDC ± 2000 mA – Dual output models: <100 mVpk-pk (20 MHz BW) TEN 20-2422WIN ± 12 VDC ± 835 mA Conducted EMI EN 55022, class EN55022 class A (with external capacitor) TEN 20-2423WIN ± 15 VDC ± 665 mA Short circuit protection continuous, automatic recovery TEN 20-4810WIN 3.3 VDC 5500 mA Efficiency 85 % typ. TEN 20-4811WIN 5 VDC 4000 mA Operating temperature –40 °C to +85 °C TEN 20-4812WIN 12 VDC 1670 mA range above 70 °C derating 2.8 %/K TEN 20-4813WIN 18 – 75 VDC 15 VDC 1330 mA I/O isolation voltage 1500 VDC (60 sec.) TEN 20-4821WIN ± 5 VDC ± 2000 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 TEN 20-4822WIN ± 12 VDC ± 835 mA approvals TEN 20-4823WIN ± 15 VDC ± 665 mA Remote On/Off shutdown input for low input current (2.5 mA) Optional heatsink: TEN-HS1 in standby operation Casing metal, 6-side shielded with insulated baseplate Full datasheet www.tracopower.com/products/ten20win.pdf Dimensions Pin Single output Dual output 7.62 7.62 1 + Vin (Vcc) + Vin (Vcc) (0.3) (0.3) 2 – Vin (GND) – Vin (GND) 3 + Vout + Vout 5.08 (0.2) 4 Trim Common 5 – Vout – Vout 6 21 6* Remote On/Off Remote On/Off Bottom view * optional no pin on request 54 3 10.16 10.16 2.5 (0.1) (0.4) (0.4) Insulated Baseplate 6 10.2 25.4 (0.24) (0.4) (1.0) () = Inches 80 50.8 (2.0) 15.2 20.32 (0.8) (0.6) www.tracopower.com High Performance DC/DC Converters TEN-20WIR Series 20 W UL 60950-1 2“ x 1“ x 0.4“ metal package Ultra wide 4:1 input range up to 160 VDC Certified for railway applications EN 50155 High efficiency across load range Low input current at no load Input undervoltage-lockout Operating temperature range –40 °C to +85 °C I/O isolation 1500 VDC Input filter to meet EN 55022 class A Remote On/Off Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2% max. max. Load regulation – Single output models: 0.5 % max. TEN 20-2410WIR 3.3 VDC 4500 mA – Dual output models: 1.0 % max. TEN 20-2411WIR 5 VDC 4000 mA Ripple & Noise <75 mVpk-pk (20 MHz BW) TEN 20-2412WIR 12 VDC 1670 mA EMC - Conducted noise: EN 55022, class EN55022 class A TEN 20-2413WIR 9 – 36 VDC 15 VDC 1330 mA (without external capacitor) TEN 20-2422WIR ± 12 VDC ± 833 mA - Immunity: EN 50155 TEN 20-2423WIR ± 15 VDC ± 667 mA Short circuit protection continuous, automatic recovery TEN 20-4810WIR 3.3 VDC 4500 mA Efficiency 88 % typ. TEN 20-4811WIR 5 VDC 4000 mA Operating temperature –40 °C to +85 °C TEN 20-4812WIR 12 VDC 1670 mA range above 70 °C derating 4.0 %/K TEN 20-4813WIR 18 – 75 VDC 15 VDC 1330 mA I/O isolation voltage 1500 VDC (60 sec.) TEN 20-4822WIR ± 12 VDC ± 833 mA Safety standards / cUL /UL 60950-1, IEC/EN 60950-1, EN 50155 TEN 20-4823WIR ± 15 VDC ± 667 mA approvals TEN 20-7210WIR 3.3 VDC 4500 mA Thermal shock and EN 61373 / MIL-STD-810F TEN 20-7211WIR 5 VDC 4000 mA shock & vibration TEN 20-7212WIR 12 VDC 1670 mA Remote On/Off shutdown input for low input current (2.5 mA) TEN 20-7213WIR 43 – 160 VDC 15 VDC 1330 mA in standby operation TEN 20-7222WIR ± 12 VDC ± 833 mA Casing metal, 6-side shielded with insulated baseplate TEN 20-7223WIR ± 15 VDC ± 667 mA Full datasheet www.tracopower.com/products/ten20wir.pdf Optional heatsink: TEN-HS1 Dimensions Pin Single output Dual output 7.62 7.62 (0.3) (0.3) 1 + Vin (Vcc) + Vin (Vcc) 2 – Vin (GND) – Vin (GND) 5.08 (0.2) 3 + Vout + Vout 4 No pin Common 5 – Vout – Vout 6 21 6 Remote On/Off Remote On/Off Bottom view 54 3 10.16 10.16 2.5 (0.1) (0.4) (0.4) Insulated Baseplate 6 10.2 25.4 (0.24) (0.4) (1.0) () = Inches 81 50.8 (2.0) 15.2 20.32 (0.8) (0.6) www.tracopower.com DC/DC Converters Chassis Mount CB TMDC-20 Series 20 W Scheme UL 60950-1 Fully encapsulated low profile plastic casing Ultra wide 4:1 input voltage range Operating temperature range –40°C to +85°C Highest efficiency up to 91 % I/O isolation 2500 VDC Remote On/Off Power-good LED indicator Reverse input protection Optional DIN-rail mount adapter Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5% max. max. Load regulation 0.5% max. TMDC 20-2411 5.1 VDC 4000 mA Ripple & noise 5.1 VDC modesl: <100 mVpk-pk (20 MHz BW) TMDC 20-2412 9 – 36 VDC 12 VDC 1670 mA 12 & 24 VDC modesl: <150 mVpk-pk (20 MHz BW) TMDC 20-2415 24 VDC 835 mA 48 VDC modesl: <200 mVpk-pk (20 MHz BW) TMDC 20-2418 48 VDC 420 mA Conducted EMI EN 55022, class EN55022 class A TMDC 20-4811 5.1 VDC 4000 mA Short circuit protection continuous, automatic recovery TMDC 20-4812 18 – 75 VDC 12 VDC 1670 mA Efficiency 90% typ. TMDC 20-4815 24 VDC 835 mA Operating temperature –40 °C to +80 °C TMDC 20-4818 48 VDC 420 mA range above 65°C derating 3.3 %/K I/O isolation voltage 2500 VDC (60 sec.) reinforced insulation Safety standards cUL/UL 60950-1, IEC/EN 60950-1 (reports pending) Remote On/Off shutdown input for low current in standby operation Casing metal, with insulated baseplate Full datasheet www.tracopower.com/products/tmdc20.pdf Dimensions DIN-rail mount adapter TMP-MK1 Type Length l Width w Height h TMDC 20-xxxx 96 (3.78) 54.0 (2.13) 23.3 (0.88) l () = Inches 82 NEW Product w h www.tracopower.com High Performance DC/DC Converters CB CB THL-25 Series 25 W Schem Schemee UL 60950-1 High power density 25 W converter 1“ x 1“ x 0.4“ metal package Wide 2:1 input voltage range Highest efficiency up to 90 % I/O isolation 1500 VDC Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output voltage Output current Line regulation 1% max. max. Load regulation – Single output models: 1.0% max. THL 25-1210 3.3 VDC 6000 mA – Dual output models: 2.0 % max. THL 25-1211 5.0 VDC 5000 mA Output voltage ±10 % by external resistor (single output models) THL 25-1212 9 – 18 VDC 12 VDC 2085 mA adjustment THL 25-1213 15 VDC 1670 mA Ripple & noise <100 mVpk-pk (20 MHz BW) THL 25-1222 ± 12 VDC ± 1042 mA Short circuit protection continuous, automatic recovery THL 25-1223 ± 15 VDC ± 835 mA Efficiency 89% typ. THL 25-2410 3.3 VDC 6000 mA Operating temperature –40 °C to +80 °C THL 25-2411 5.0 VDC 5000 mA range above 50°C derating 1.7 %/K THL 25-2412 18 – 36 VDC 12 VDC 2085 mA - optional heatsink for extended temp.: see datasheet THL 25-2413 15 VDC 1670 mA I/O isolation voltage 1500 VDC (60 sec.) THL 25-2422 ± 12 VDC ± 1042 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 (reports pending) THL 25-2423 ± 15 VDC ± 835 mA Remote On/Off shutdown input for low current THL 25-4810 3.3 VDC 6000 mA in standby operation THL 25-4811 5.0 VDC 5000 mA Casing metal, with insulated baseplate THL 25-4812 36 – 75 VDC 12 VDC 2085 mA THL 25-4813 15 VDC 1670 mA Full datasheet www.tracopower.com/products/thl25.pdf THL 25-4822 ± 12 VDC ± 1042 mA THL 25-4823 ± 15 VDC ± 835 mA Optional heatsink: THL-HS1 Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 7.62 2 – Vin (GND) – Vin (GND) 5.08 (0.2) 3 + Vout + Vout (0.3) 4 Trim Common 2 1 6 5 – Vout – Vout 6 Remote On/Off Remote On/Off Bottom view 5 4 3 6.0 10.2 2.5 10.16 10.16 (0.24) (0.1) (0.4) (0.4) (0.4) 25.4 (1.0) () = Inches 83 20.32 (0.8) 2.5 (0.1) 25.4 (1.0) www.tracopower.com DC/DC Converters High Performance CB CB THL-25WI Series 25 W Schem Schemee UL 60950-1 High power density 25 W converter 1“ x 1“ x 0.4“ metal package Ultra wide 4:1 input voltage range Highest efficiency up to 90 % I/O isolation 1500 VDC Remote On/Off Adjustable output voltage Industry standard pinout Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2% max. max. Load regulation – Single output models: 0.2% max. THL 25-2410WI 3.3 VDC 6000 mA – Dual output models: 1.0 % max. THL 25-2411WI 5.0 VDC 5000 mA Output voltage ±10 % by external resistor (single output models) THL 25-2412WI 9 – 36 VDC 12 VDC 2090 mA adjustment THL 25-2413WI 15 VDC 1670 mA Ripple & noise <150 mVpk-pk (20 MHz BW) THL 25-2422WI ± 12 VDC ± 1040 mA Conducted EMI EN 55022, class EN55022 class A THL 25-2423WI ± 15 VDC ± 840 mA Short circuit protection continuous, automatic recovery THL 25-4810WI 3.3 VDC 6000 mA Efficiency 89% typ. THL 25-4811WI 5.0 VDC 5000 mA THL 25-4812WI 18 – 75 VDC 12 VDC 2090 mA Operating temperature –40 °C to +80 °C range above 50°C derating 1.7 %/K (depending on model) THL 25-4813WI 15 VDC 1670 mA - optional heatsink for extended temp.: see datasheet THL 25-4822WI ± 12 VDC ± 1040 mA I/O isolation voltage 1500 VDC (60 sec.) THL 25-4823WI ± 15 VDC ± 840 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 (reports pending) Optional heatsink: THL-HS1 Remote On/Off shutdown input for low current in standby operation Casing metal, with insulated baseplate Full datasheet www.tracopower.com/products/thl25wi.pdf Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 7.62 5.08 2 – Vin (GND) – Vin (GND) (0.2) (0.3) 3 + Vout + Vout 4 Trim Common 2 1 6 5 – Vout – Vout 6 Remote On/Off Remote On/Off Bottom view 5 4 3 6.0 10.2 2.5 10.16 10.16 (0.24) (0.1) (0.4) (0.4) (0.4) 25.4 (1.0) () = Inches 84 NEW Product 20.32 (0.8) 2.5 (0.1) 25.4 (1.0) www.tracopower.com High Performance DC/DC Converters CB CB TEN-30 Series 30 W Schem Schemee UL 60950-1 2“ x 1“ x 0.4“ shielded metal package Wide 2:1 input voltage range Very high efficiency up to 91 % Operating temperature range –40 °C to +85 °C Over-temperature protection I/O-isolation 1500 VDC Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2% max. max. TEN 30-1207 1.5 VDC 8500 mA Load regulation – Single output models: 0.5 % max. – Dual output models: 1.0 % max. TEN 30-1209 2.5 VDC 8000 mA TEN 30-1210 3.3 VDC 8000 mA Output voltage ±10 % by external resistor adjustment (single output models only) TEN 30-1211 5.1 VDC 6000 mA TEN 30-1212 9 – 18 VDC 12 VDC 2500 mA Ripple & noise – Single output models: <100 mVpk-pk (20 MHz BW) – Dual output models: <150 mVpk-pk (20 MHz BW) TEN 30-1213 15 VDC 2000 mA Conducted EMI EN 55022, class EN55022 class A (with external capacitor) TEN 30-1221 ±5 VDC ±3000 mA TEN 30-1222 ±12 VDC ±1250 mA Short circuit protection continuous, automatic recovery TEN 30-1223 ±15 VDC ±1000 mA Efficiency 89 % typ. TEN 30-2407 1.5 VDC 8500 mA Operating temperature –40 °C to +85 °C TEN 30-2409 2.5 VDC 8000 mA range above 65 °C derating 2.6 %/K TEN 30-2410 3.3 VDC 8000 mA Thermal protection shutdown at 115 °C TEN 30-2411 5.1 VDC 6000 mA I/O isolation voltage 1500 VDC (60 sec.) TEN 30-2412 18 – 36 VDC 12 VDC 2500 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 CB-report TEN 30-2413 15 VDC 2000 mA / approvals TEN 30-2421 ±5 VDC ±3000 mA Remote On/Off shutdown input for low input current (3 mA) TEN 30-2422 ±12 VDC ±1250 mA in standby operation TEN 30-2423 ±15 VDC ±1000 mA Casing 6-side shielded metal, with insulated baseplate TEN 30-4807 1.5 VDC 8500 mA Full datasheet www.tracopower.com/products/ten30.pdf TEN 30-4809 2.5 VDC 8000 mA TEN 30-4810 3.3 VDC 8000 mA TEN 30-4811 5.1 VDC 6000 mA TEN 30-4812 36 – 75 VDC 12 VDC 2500 mA TEN 30-4813 15 VDC 2000 mA TEN 30-4821 ±5 VDC ±3000 mA TEN 30-4822 ±12 VDC ±1250 mA TEN 30-4823 ±15 VDC ±1000 mA Optional heatsink: TEN-HS1 Dimensions Pin Single output Dual output 15.24 1 + Vin (Vcc) + Vin (Vcc) (0.6) 5.08 2.54 2 – Vin (GND) – Vin (GND) (0.2) (0.1) 3 Remote On/Off Remote On/Off 5.08 (0.2) 4 + Vout + Vout 3 2 1 5 – Vout Common 6 Trim – Vout Bottom View 6 5 4 5.6 10.16 (0.22) (0.4) 10.2 20.32 (0.4) (0.8) 25.4 (1.0) () = Inches 85 45.72 (1.8) 2.5 (0.1) 50.8 (2.0) www.tracopower.com DC/DC Converters High Performance CB CB C CBB TEN-30WIN Series 30 W Schem Schem Scheme Schemeee UL UL 60 60950- 950-1 1 2“ x 1“ x 0.4“ shielded metal package Ultra wide 4:1 input voltage range Single- dual- and triple output models Very high efficiency up to 91 % Operating temperature range –40 °C to +85 °C Over temperature protection I/O isolation 1500 VDC Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output 1 Output 2 Line regulation – Single and dual output models: 0.2% max. Vout / Iout max. Vout / Iout max. – Triple output models: 1.0% max. TEN 30-2407WIN 1.5 VDC / 8.5 A Load regulation – Single output models: 0.5 % max. TEN 30-2409WIN 2.5 VDC / 8.0 A – Dual output models: 1.0 % max. TEN 30-2410WIN 3.3 VDC / 7.5 A – Triple output models: Vout 1: 1% max, Vout 2: 5.0% max. TEN 30-2411WIN 5.1 VDC / 6.0 A Output voltage ±10 % by external resistor TEN 30-2412WIN 12 VDC / 2.5 A adjustment (single output models only) TEN 30-2413WIN 15 VDC / 2.0 A Ripple & noise – Single output models: <100 mVpk-pk (20 MHz BW) TEN 30-2421WIN 9 – 36 VDC +5 VDC / 3.0 A -5 VDC / 3.0 A – Dual output models: <150 mVpk-pk (20 MHz BW) TEN 30-2422WIN +12 VDC / 1.25 A -12 VDC / 1.25 A Conducted EMI EN 55022, class EN55022 class A (with external capacitor) TEN 30-2423WIN +15 VDC / 1.0 A -15 VDC / 1.0 A Short circuit protection continuous, automatic recovery TEN 30-2433WIN 3.3 VDC / 5.0 A ±12 VDC / ± 0.42 A Efficiency 87 % typ. TEN 30-2434WIN 3.3 VDC / 5.0 A ±15 VDC / ± 0.33 A Operating temperature –40 °C to +85 °C TEN 30-2431WIN 5 VDC / 4.0 A ±12 VDC / ± 0.42 A range above 60 °C derating 2.4 %/K TEN 30-2432WIN 5 VDC / 4.0 A ±15 VDC / ± 0.33 A Thermal protection shutdown at 115 °C TEN 30-4807WIN 1.5 VDC / 8.5 A I/O isolation voltage 1500 VDC (60 sec.) TEN 30-4809WIN 2.5 VDC / 8.0 A Safety standards cUL/UL 60950-1, IEC/EN 60950-1 CB-report TEN 30-4810WIN 3.3 VDC / 7.5 A / approvals TEN 30-4811WIN 5.1 VDC / 6.0 A Remote On/Off shutdown input for low input current (2.5 mA) TEN 30-4812WIN 12 VDC / 2.5 A in standby operation TEN 30-4813WIN 15 VDC / 2.0 A Casing 6-side shielded metal, with insulated baseplate TEN 30-4821WIN 18 – 75 VDC +5 VDC / 3.0 A -5 VDC / 3.0 A Full datasheet www.tracopower.com/products/ten30win.pdf TEN 30-4822WIN +12 VDC / 1.25 A -12 VDC / 1.25 A TEN 30-4823WIN +15 VDC / 1.0 A -15 VDC / 1.0 A TEN 30-4833WIN 3.3 VDC / 5.0 A ±12 VDC / ± 0.42 A TEN 30-4834WIN 3.3 VDC / 5.0 A ±15 VDC / ± 0.33 A TEN 30-4831WIN 5 VDC / 4.0 A ±12 VDC / ± 0.42 A TEN 30-4832WIN 5 VDC / 4.0 A ±15 VDC / ± 0.33 A Optional heatsink: TEN-HS1 Dimensions Single- and dual output models Triple output models Pin Single output Dual output Triple output 15.24 12.7 1 + Vin (Vcc) + Vin (Vcc) + Vin (Vcc) (0.6) (0.5) 5.08 2.54 5.08 7.62 2 – Vin (GND) – Vin (GND) – Vin (GND) (0.2) (0.1) (0.2) (0.3) 5.08 10.16 3 Remote On/Off Remote On/Off Remote On/Off (0.2) (0.4) 4 + Vout Output 1 Output 2 3 2 1 3 2 1 5 – Vout Common Output 3 6 Trim Output 2 Common 7 No pin No pin Output 1 Bottom View Bottom View 6 5 4 7 6 5 4 5.6 10.16 5.08 (0.22) (0.4) (0.2) 10.2 20.32 (0.4) (0.8) 25.4 25.4 (1.0) (1.0) () = Inches 86 45.72 (1.8) 2.5 (0.1) 50.8 (2.0) www.tracopower.com High Performance DC/DC Converters CB CB THN-30 Series 30 W Schem Schemee UL 60950-1 Highest power density 30 W converter 1“ x 1“ x 0.4“ 6-side shielded metal casing Wide 2:1 input voltage range Very high efficiency up to 91 % Low input current at no load High efficiency accross load range Operating temperature range –40 °C to +80 °C Over-temperature protection I/O-isolation 1500 VDC Input undervoltage-lockout Remote On/Off and output trim Specifications Models Order code Input voltage Output voltage Output current Line regulation – Single output models: 0.2 % max. max. – Dual output models: 0.5 % max. THN 30-1210 3.3 VDC 7000 mA Load regulation – Single output models: 0.2 % max. THN 30-1211 5.0 VDC 6000 mA – Dual output models: 1.0 % max. THN 30-1212 12 VDC 2500 mA Output voltage 12 & 15 VDC models: +20 / -10% THN 30-1213 9 – 18 VDC 15 VDC 2000 mA adjustment other single output models: ±10% THN 30-1215 24 VDC 1250 mA by external resistor THN 30-1222 ±12 VDC ±1250 mA Ripple & noise <100 mVpk-pk (20 MHz BW) THN 30-1223 ±15 VDC ±1000 mA Conducted EMI EN 55022, class EN55022 class A THN 30-2410 3.3 VDC 7000 mA (with external capacitor and inductor) THN 30-2411 5.0 VDC 6000 mA Short circuit protection continuous, automatic recovery THN 30-2412 12 VDC 2500 mA Efficiency 90 % typ. THN 30-2413 18 – 36 VDC 15 VDC 2000 mA Operating temperature –40 °C to +80 °C THN 30-2415 24 VDC 1250 mA range above 55 °C derating 2.2 %/K THN 30-2422 ±12 VDC ±1250 mA Thermal protection shutdown at 115 °C THN 30-2423 ±15 VDC ±1000 mA I/O isolation voltage 1500 VDC (60 sec.) THN 30-4810 3.3 VDC 7000 mA THN 30-4811 5.0 VDC 6000 mA Safety standards cUL/UL 60950-1, IEC/EN 60950-1 (reports pending) / approvals THN 30-4812 12 VDC 2500 mA THN 30-4813 36 – 75 VDC 15 VDC 2000 mA Remote On/Off shutdown input for low input current (2 mA) in standby operation THN 30-4815 24 VDC 1250 mA THN 30-4822 ±12 VDC ±1250 mA Casing 6-side shielded metal, with insulated baseplate THN 30-4823 ±15 VDC ±1000 mA Full datasheet www.tracopower.com/products/thn30.pdf Optional heatsink: THN-HS1 Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 7.62 5.08 2 – Vin (GND) – Vin (GND) (0.2) 3 Remote On/Off Remote On/Off (0.3) 4 + Vout + Vout 2 1 6 5 – Vout Common 6 Trim – Vout Bottom view 5 4 3 6.0 9.9 2.5 10.16 10.16 (0.1) (0.4) (0.4) (0.24) (0.39) 25.4 (1.0) () = Inches 87 20.32 (0.8) 2.5 (0.1) 25.4 (1.0) www.tracopower.com DC/DC Converters High Performance CB CB THN-30WI Series 30 W Schem Schemee UL 60950-1 Highest power density 30 W converter 1“ x 1“ x 0.4“ 6-side shielded metalcase Ultra wide 4:1 input voltage range Very high efficiency up to 91 % Low input current at no load High efficiency accross load range Operating temperature range –40 °C to +80 °C Over-temperature protection I/O-isolation 1500 VDC Input undervoltage-lockout Remote On/Off and output trim Specifications Models Order code Input voltage Output voltage Output current Line regulation – Single output models: 0.2 % max. max. – Dual output models: 0.5 % max. THN 30-2410WI 3.3 VDC 7000 mA Load regulation – Single output models: 0.2 % max. THN 30-2411WI 5.0 VDC 6000 mA – Dual output models: 1.0 % max. THN 30-2412WI 12 VDC 2500 mA Output voltage 12 & 15 VDC models: +20 / -10% THN 30-2413WI 9 – 36 VDC 15 VDC 2000 mA adjustment other single output models: ±10% THN 30-2415WI 24 VDC 1250 mA by external resistor THN 30-2422WI ±12 VDC ±1250 mA Ripple & noise <100 mVpk-pk (20 MHz BW) THN 30-2423WI ±15 VDC ±1000 mA Conducted EMI EN 55022, class EN55022 class A THN 30-4810WI 3.3 VDC 7000 mA (with external capacitor and inductor) THN 30-4811WI 5.0 VDC 6000 mA Short circuit protection continuous, automatic recovery THN 30-4812WI 12 VDC 2500 mA Efficiency 90 % typ. THN 30-4813WI 18 – 75 VDC 15 VDC 2000 mA Operating temperature –40 °C to +80 °C THN 30-4815WI 24 VDC 1250 mA range above 55 °C derating 2.4 %/K THN 30-4822WI ±12 VDC ±1250 mA Thermal protection shutdown at 115 °C THN 30-4823WI ±15 VDC ±1000 mA I/O isolation voltage 1500 VDC (60 sec.) Optional heatsink: THN-HS1 Safety standards cUL/UL 60950-1, IEC/EN 60950-1 (reports pending) / approvals Remote On/Off shutdown input for low input current (2 mA) in standby operation Casing 6-side shielded metal, with insulated baseplate Full datasheet www.tracopower.com/products/thn30wi.pdf Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 7.62 5.08 2 – Vin (GND) – Vin (GND) (0.2) (0.3) 3 Remote On/Off Remote On/Off 4 + Vout + Vout 2 1 6 5 – Vout Common 6 Trim – Vout Bottom view 5 4 3 2.5 10.16 10.16 6.0 9.9 (0.1) (0.4) (0.4) (0.24) (0.39) 25.4 (1.0) () = Inches 88 20.32 (0.8) 2.5 (0.1) 25.4 (1.0) www.tracopower.com High Performance DC/DC Converters CB CB TEN-40 Series 40 W Schem Schemee UL 60950-1 Models with 2 isolated outputs (3.3 V / 5 V) Triple output models Wide 2:1 input range High efficiency up to 90 % Operating temperature range –40 °C to +75 °C I/O isolation 1500 VDC Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output 1 Output 2 Line regulation 1.0 % max. Vout / Imax. Vout / Imax Load regulation – Single output models: 0.5 % max. TEN 40-1210 3.3 VDC / 8.0 A – Dual output models: 1.0 % max. TEN 40-1211 5 VDC / 8.0 A – Triple output models: Vout 1: 1% max, Vout 2: 5.0% max. TEN 40-1212 12 VDC / 3.3 A Output voltage ±10 % by external resistor TEN 40-1220 *3.3 VDC / 8.0 A *5 VDC / 8.0 A adjustment (only for single and symmetric dual output models) TEN 40-1222 9 – 18 VDC + 12 VDC / 1.8 A -12 VDC / 1.8 A TEN 40-1223 + 15 VDC / 1.4 A -15 VDC / 1.4 A Ripple & noise – 3.3 / 5 VDC output models: <50 mVpk-pk (20 MHz BW) – Symmetric dual output models: <150 mVpk-pk TEN 40-1233 3.3 VDC / 6.0 A ± 12 VDC / ± 0.4 A – Asymmetric dual output models: <100 mVpk-pk TEN 40-1234 3.3 VDC / 6.0 A ± 15 VDC / ± 0.3 A – all other output models <75 mVpk-pk TEN 40-1231 5 VDC / 6.0 A ± 12 VDC / ± 0.4 A Conducted EMI EN 55022, class EN55022 class A TEN 40-1232 5 VDC / 6.0 A ± 15 VDC / ± 0.3 A (with external capacitor) TEN 40-2410 3.3 VDC / 8.0 A TEN 40-2411 5 VDC / 8.0 A Short circuit protection continuous, automatic recovery TEN 40-2412 12 VDC / 3.3 A Efficiency 86 % typ. TEN 40-2420 *3.3 VDC / 8.0 A *5 VDC / 8.0 A Operating temperature –40 °C to +75 °C TEN 40-2422 18 – 36 VDC + 12 VDC / 1.8 A -12 VDC / 1.8 A range for derating see datasheet TEN 40-2423 + 15 VDC / 1.4 A -15 VDC / 1.4 A Thermal protection shutdown at 115 °C TEN 40-2433 3.3 VDC / 6.0 A ± 12 VDC / ± 0.4 A I/O isolation voltage 1500 VDC (60 sec.) TEN 40-2434 3.3 VDC / 6.0 A ± 15 VDC / ± 0.3 A Safety standards / cUL /UL 60950-1, IEC/EN 60950-1 CB-report TEN 40-2431 5 VDC / 6.0 A ± 12 VDC / ± 0.4 A approvals TEN 40-2432 5 VDC / 6.0 A ± 15 VDC / ± 0.3 A Remote On/Off shutdown input for low input current (2.5 mA) TEN 40-4810 3.3 VDC / 8.0 A in standby operation TEN 40-4811 5 VDC / 8.0 A Casing 6-side shielded metal, with insulated baseplate TEN 40-4812 12 VDC / 3.3 A TEN 40-4820 *3.3 VDC / 8.0 A *5 VDC / 8.0 A Full datasheet www.tracopower.com/products/ten40.pdf TEN 40-4822 36 – 75 VDC + 12 VDC / 1.8 A -12 VDC / 1.8 A TEN 40-4823 + 15 VDC / 1.4 A -15 VDC / 1.4 A TEN 40-4833 3.3 VDC / 6.0 A ± 12 VDC / ± 0.4 A TEN 40-4834 3.3 VDC / 6.0 A ± 15 VDC / ± 0.3 A TEN 40-4831 5 VDC / 6.0 A ± 12 VDC / ± 0.4 A TEN 40-4832 5 VDC / 6.0 A ± 15 VDC / ± 0.3 A *dynamic current allocation, max. 8 A total output current Optional heatsink: TEN-HS3 Dimensions Dual output Dual output Pin Single output Triple output symmetric asymmetric 1 + Vin (Vcc) + Vin (Vcc) + Vin (Vcc) + Vin (Vcc) 9 2 – Vin (GND) – Vin (GND) – Vin (GND) – Vin (GND) 8 3 3 Remote On/Off 7 4 No con. No pin +Vout 1 +Vout 2 2 Bottom 6 5 –Sense Vout 1 -Vout 1 Common 2 1 view 5 6 +Sense Common 1/2 No con. -Vout 2 4 7 +Vout Common 1/2 No con. +Vout 1 8 -Vout Vout 2 +Vout 2 -Vout 1 9 Trim Trim -Vout 2 No con. 5.6 45.72 (1.8) (0.22) 10.2 50.8 (2.0) (0.4) () = Inches 89 50.8 (2.0) 2.54 5.08 7.62 5.08 (0.1) (0.2) (0.3) (0.2) 5.08 5.08 (0.2) (0.2) 5.08 10.16 (0.2) (0.4) 27.9 (1.10) www.tracopower.com DC/DC Converters High Performance CB CB TEN-40WI Series 40 W Schem Schemee UL 60950-1 Ultra wide 4:1 input range Operating temperature range –40 °C to +85 °C Over temperature protection I/O isolation 1500 VDC Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation – Single output models: 0.5 % max. TEN 40-2410WI 3.3 VDC 10000 mA – Dual/Triple output models: 1.0 % max. TEN 40-2411WI 5 VDC 8000 mA Output voltage ±10 % by external resistor TEN 40-2412WI 9 – 36 VDC 12 VDC 3330 mA adjustment TEN 40-2413WI 15 VDC 2660 mA Ripple & noise – 3.3 / 5 VDC output models: <50 mVpk-pk TEN 40-2422WI ± 12 VDC ± 1667 mA (20 MHz BW) – other single output models: <75 mVpk-pk TEN 40-2423WI ± 15 VDC ± 1333 mA – dual output models: <150 mVpk-pk TEN 40-4810WI 3.3 VDC 10000 mA Conducted EMI EN 55022, class EN55022 class A TEN 40-4811WI 5 VDC 8000 mA (with external capacitor) TEN 40-4812WI 18 – 75 VDC 12 VDC 3333 mA Short circuit protection continuous, automatic recovery TEN 40-4813WI 15 VDC 2666 mA Efficiency 86 % typ. TEN 40-4822WI ± 12 VDC ± 1667 mA Operating temperature –40 °C to +85 °C TEN 40-4823WI ± 15 VDC ± 1333 mA range above 55 °C derating 2.0 %/K Optional heatsink: TEN-HS3 Thermal protection shutdown at 110 °C I/O isolation voltage 1500 VDC (60 sec.) Safety standards / cUL /UL 60950-1, IEC/EN 60950-1 CB-report approvals Remote On/Off shutdown input for low input current (3 mA) in standby operation Casing 6-side shielded metal, with insulated baseplate Full datasheet www.tracopower.com/products/ten40wi.pdf Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 2 – Vin (GND) – Vin (GND) 8 3 Remote On/Off Remote On/Off 7 3 4 – Sense + Vout 6 5 + Sense Common 2 Bottom 5 6 + Vout Common 1 view 7 – Vout – Vout 4 8 Trim Trim 5.6 45.72 (1.8) (0.22) 10.2 50.8 (2.0) (0.4) () = Inches 90 50.8 (2.0) 2.54 5.08 7.62 5.08 (0.1) (0.2) (0.3) (0.2) 5.08 (0.2) 5.08 10.16 (0.2) (0.4) 27.9 (1.10) www.tracopower.com High Performance DC/DC Converters C CBB TEN-40N Series 40 W Schem Schemee UL 60950-1 High power density 40 W converter 2“ x 1“ x 0.4“ metal package Wide 2:1 input range High efficiency up to 92 % Operating temperature range –40 °C to +75 °C I/O isolation 1500 VDC Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation – Single output models: 1.0 % max. TEN 40-1210N 3.3 VDC 8000 mA – Dual output models: 2.0 % max. TEN 40-1211N 5.0 VDC 8000 mA Output voltage ±10 % by external resistor (single output models) TEN 40-1212N 12 VDC 3333 mA adjustment TEN 40-1213N 9 – 18 VDC 15 VDC 2666 mA Ripple & noise 100 mVpk-pk typ. (20 MHz BW) TEN 40-1215N 24 VDC 1670 mA Conducted EMI EN 55022, class EN55022 class A (external capacitors) TEN 40-1222N ±12 VDC ±1666 mA Short circuit protection continuous, automatic recovery TEN 40-1223N ±15 VDC ±1333 mA Efficiency 90 % typ. TEN 40-2410N 3.3 VDC 8000 mA TEN 40-2411N 5.0 VDC 8000 mA Operating temperature –40 °C to +75 °C range above 45 °C derating 1.6 %/K TEN 40-2412N 12 VDC 3333 mA I/O isolation voltage 1500 VDC (60 sec.) TEN 40-2413N 18 – 36 VDC 15 VDC 2666 mA TEN 40-2415N 24 VDC 1670 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 CB-report approvals TEN 40-2422N ±12 VDC ±1666 mA TEN 40-2423N ±15 VDC ±1333 mA Remote On/Off shutdown input for low input current (2.5 mA) in standby operation TEN 40-4810N 3.3 VDC 8000 mA TEN 40-4811N 5.0 VDC 8000 mA Casing metal, with insulated baseplate TEN 40-4812N 12 VDC 3333 mA Full datasheet www.tracopower.com/products/ten40n.pdf TEN 40-4813N 36 – 75 VDC 15 VDC 2666 mA TEN 40-4815N 24 VDC 1670 mA TEN 40-4822N ±12 VDC ±1666 mA TEN 40-4823N ±15 VDC ±1333 mA Optional heatsink: TEN-HS4 Dimensions Pin Single output Dual output 15.24 (0.6) 1 + Vin (Vcc) + Vin (Vcc) 5.08 2.54 (0.2) (0.1) 2 – Vin (GND) – Vin (GND) 5.08 (0.2) 3 Remote On/Off Remote On/Off 4 + Vout + Vout 3 2 1 5 – Vout Common 6 Trim – Vout Bottom View 6 5 4 5.1 10.16 (0.20) (0.4) 10.2 20.32 (0.4) (0.8) 25.4 (1.0) () = Inches 91 NEW Models 45.72 (1.8) 2.5 (0.1) 50.8 (2.0) www.tracopower.com DC/DC Converters High Performance CB CB TEN-40WIN Series 40 W Schem Schemee UL 60950-1 High power density 40 W converter 2“ x 1“ x 0.4“ metal package Ultra wide 4:1 input range High efficiency up to 90 % Operating temperature range –40 °C to +75 °C I/O isolation 1500 VDC Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation – Single output models: 0.5 % max. TEN 40-2410WIN 3.3 VDC 8000 mA – Dual/Triple output models: 1.0 % max. TEN 40-2411WIN 5.0 VDC 8000 mA Output voltage ±10 % by external resistor TEN 40-2412WIN 9 – 36 VDC 12 VDC 3330 mA adjustment TEN 40-2413WIN 15 VDC 2670 mA Ripple & noise – 3.3 / 5 VDC output models: <100 mVpk-pk TEN 40-2415WIN 24 VDC 1670 mA (20 MHz BW) – other output models: <150 mVpk-pk TEN 40-2422WIN ±12 VDC ±1670 mA Conducted EMI EN 55022, class EN55022 class A TEN 40-2423WIN ±15 VDC ±1330 mA (with external capacitors) TEN 40-4810WIN 3.3 VDC 8000 mA Short circuit protection continuous, automatic recovery TEN 40-4811WIN 5.0 VDC 8000 mA Efficiency 89 % typ. TEN 40-4812WIN 18 – 75 VDC 12 VDC 3330 mA Operating temperature –40 °C to +75 °C TEN 40-4813WIN 15 VDC 2670 mA range above 45 °C derating 1.6 %/K TEN 40-4815WIN 24 VDC 1670 mA I/O isolation voltage 1500 VDC (60 sec.) TEN 40-4822WIN ±12 VDC ±1670 mA Safety standards / cUL /UL 60950-1, IEC/EN 60950-1, CB-report TEN 40-4823WIN ±15 VDC ±1330 mA approvals Optional heatsink: TEN-HS4 Remote On/Off shutdown input for low input current (2.5 mA) in standby operation Casing metal, shielded with insulated baseplate Full datasheet www.tracopower.com/products/ten40win.pdf Dimensions Pin Single output Dual output 15.24 (0.6) 1 + Vin (Vcc) + Vin (Vcc) 5.08 2.54 (0.2) (0.1) 2 – Vin (GND) – Vin (GND) 5.08 (0.2) 3 Remote On/Off Remote On/Off 4 + Vout + Vout 3 2 1 5 – Vout Common 6 Trim – Vout Bottom View 6 5 4 5.1 10.16 (0.20) (0.4) 10.2 20.32 (0.4) (0.8) 25.4 (1.0) () = Inches 92 45.72 (1.8) 2.5 (0.1) 50.8 (2.0) www.tracopower.com High Performance DC/DC Converters CB CB TEN-40WIR Series 40 W Schem Schemee UL 60950-1 High power density 40 W converter 2“ x 1“ x 0.4“ metal package Ultra wide 4:1 input range up to 160 VDC Certified for railway applications EN 50155 High efficiency across load range Low input current at no load Operating temperature range –40 °C to +85 °C Over temperature protection I/O isolation 1500 VDC Input undervoltage-lockout Remote On/Off and output trim Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation – Single output models: 0.5 % max. TEN 40-2410WIR 3.3 VDC 10‘000 mA – Dual output models: 1.0 % max. TEN 40-2411WIR 5 VDC 8000 mA Output voltage ±10 % by external resistor (single output models) TEN 40-2412WIR 12 VDC 3333 mA adjustment TEN 40-2413WIR 9 – 36 VDC 15 VDC 2666 mA Ripple & noise 100 mVpk-pk typ. (20 MHz BW) TEN 40-2415WIR 24 VDC 1666 mA EMC - Conducted noise: EN 55022, class EN55022 class A TEN 40-2422WIR ± 12 VDC ± 1666 mA (with external capacitor) TEN 40-2423WIR ± 15 VDC ± 1333 mA - Immunity: EN 50155 TEN 40-4810WIR 3.3 VDC 10‘000 mA Short circuit protection continuous, automatic recovery TEN 40-4811WIR 5 VDC 8000 mA Efficiency 90 % typ. TEN 40-4812WIR 12 VDC 3333 mA Operating temperature –40 °C to +85 °C TEN 40-4813WIR 18 – 75 VDC 15 VDC 2666 mA range above 60 °C derating 2.6 %/K TEN 40-4815WIR 24 VDC 1666 mA Thermal protection shutdown at 115 °C TEN 40-4822WIR ± 12 VDC ± 1666 mA I/O isolation voltage 1500 VDC (60 sec.) TEN 40-4823WIR ± 15 VDC ± 1333 mA Thermal shock and EN 61373 / MIL-STD-810F TEN 40-7210WIR 3.3 VDC 10‘000 mA shock & vibration TEN 40-7211WIR 5 VDC 8000 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, EN 50155, CB-report TEN 40-7212WIR 12 VDC 3333 mA approvals TEN 40-7213WIR 43 – 160 VDC 15 VDC 2666 mA Remote On/Off shutdown input for low input current (3 mA) TEN 40-7215WIR 24 VDC 1666 mA in standby operation TEN 40-7222WIR ± 12 VDC ± 1666 mA Casing 6-side shielded metal, with insulated baseplate TEN 40-7223WIR ± 15 VDC ± 1333 mA Full datasheet www.tracopower.com/products/ten40wir.pdf Optional heatsink: TEN-HS1 Dimensions Pin Single output Dual output 15.24 (0.6) 1 + Vin (Vcc) + Vin (Vcc) 5.08 2.54 (0.2) (0.1) 2 – Vin (GND) – Vin (GND) 5.08 (0.2) 3 Remote On/Off Remote On/Off 4 + Vout + Vout 3 2 1 5 – Vout Common 6 Trim – Vout Bottom View 6 5 4 5.1 10.16 (0.20) (0.4) 10.2 20.32 (0.4) (0.8) 25.4 (1.0) () = Inches 93 45.72 (1.8) 2.5 (0.1) 50.8 (2.0) www.tracopower.com DC/DC Converters Chassis Mount CB TMDC-40 Series 40 W Scheme UL 60950-1 Fully encapsulated low profile plastic casing Ultra wide 4:1 input voltage range Operating temperature range –40°C to +85°C Highest efficiency up to 91 % I/O isolation 2500 VDC Remote On/Off Power-good LED indicator Reverse input protection Optional DIN-rail mount adapter Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5% max. max. Load regulation 1.0% max. TMDC 40-2411 5.1 VDC 8000 mA Ripple & noise 5.1 VDC modesl: <100 mVpk-pk (20 MHz BW) TMDC 40-2412 9 – 36 VDC 12 VDC 3330 mA 12 & 24 VDC modesl: <150 mVpk-pk (20 MHz BW) TMDC 40-2415 24 VDC 1670 mA 48 VDC modesl: <200 mVpk-pk (20 MHz BW) TMDC 40-2418 48 VDC 835 mA Conducted EMI EN 55022, class EN55022 class A TMDC 40-4811 5.1 VDC 8000 mA Short circuit protection continuous, automatic recovery TMDC 40-4812 18 – 75 VDC 12 VDC 3330 mA Efficiency 90% typ. TMDC 40-4815 24 VDC 1670 mA Operating temperature –40 °C to +85 °C TMDC 40-4818 48 VDC 835 mA range above 70°C derating 3.3 %/K I/O isolation voltage 2500 VDC (60 sec.) reinforced insulation Safety standards cUL/UL 60950-1, IEC/EN 60950-1 (reports pending) Remote On/Off shutdown input for low current in standby operation Casing metal, with insulated baseplate Full datasheet www.tracopower.com/products/tmdc40.pdf Dimensions DIN-rail mount adapter TMP-MK2 Type Length l Width w Height h TMDC 40-xxxx 112 (4.41) 63.8 (2.51) 25.6 (1.01) l () = Inches 94 NEW Product w h www.tracopower.com High Performance DC/DC Converters CB CB TEN-50 Series 50 W Schem Schemee UL 60950-1 High power density 50 W converter 2“ x 1“ x 0.4“ metal package Wide 2:1 input range High efficiency up to 92 % Operating temperature range –40 °C to +75 °C EN 55022, class A I/O isolation 1500 VDC Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation 0.5 % max. TEN 50-1210 3.3 VDC 10000 mA Output voltage ±10 % by external resistor TEN 50-1211 5 VDC 10000 mA adjustment TEN 50-1212 9 – 18 VDC 12 VDC 4167 mA Conducted EMI EN 55022, class A (with external capacitor) TEN 50-1213 15 VDC 3333 mA Ripple & noise 100 mVpk-pk typ. (20 MHz BW) TEN 50-1215 24 VDC 2080 mA Short circuit protection continuous, automatic recovery TEN 50-2410 3.3 VDC 10000 mA Efficiency 92 % typ. TEN 50-2411 5 VDC 10000 mA TEN 50-2412 18 – 36 VDC 12 VDC 4167 mA Operating temperature –40 °C to +75 °C TEN 50-2413 15 VDC 3333 mA range above 55 °C derating 2.0 %/K TEN 50-2415 24 VDC 2080 mA I/O isolation voltage 1500 VDC (60 sec.) TEN 50-4810 3.3 VDC 10000 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report TEN 50-4811 5 VDC 10000 mA approvals TEN 50-4812 36 – 75 VDC 12 VDC 4167 mA Remote On/Off shutdown input for low input current (2.5 mA) TEN 50-4813 15 VDC 3333 mA in standby operation TEN 50-4815 24 VDC 2080 mA Casing metal, with insulated baseplate Full datasheet www.tracopower.com/products/ten50.pdf Optional heatsink: TEN-HS4 Dimensions Pin Single output 15.24 (0.6) 1 + Vin (Vcc) 5.08 2.54 (0.2) (0.1) 2 – Vin (GND) 5.08 (0.2) 3 Remote On/Off 4 + Vout 3 2 1 5 – Vout 6 Trim Bottom View 6 5 4 5.1 10.16 (0.20) (0.4) 10.2 20.32 (0.4) (0.8) 25.4 (1.0) () = Inches 95 NEW Models 45.72 (1.8) 2.5 (0.1) 50.8 (2.0) www.tracopower.com DC/DC Converters High Performance CB CB TEN-50WI Series 50 W Schem Schemee UL 60950-1 High power density 50 W converter 2“ x 1“ x 0.4“ metal package Ultra wide 4:1 input range High efficiency up to 92 % Operating temperature range –40 °C to +80 °C I/O isolation 1500 VDC Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation 0.5 % max. TEN 50-2410WI 3.3 VDC 10000 mA Output voltage ±10 % by external resistor TEN 50-2411WI 5 VDC 10000 mA adjustment 24 VDC models: +20 / -10 % TEN 50-2412WI 9 – 36 VDC 12 VDC 4170 mA Ripple & noise 3.3 & 5 VDC models: <100 mVpk-pk typ. (20 MHz BW) TEN 50-2413WI 15 VDC 3330 mA other models: <150 mVpk-pk typ. (20 MHz BW) TEN 50-2415WI 24 VDC 2080 mA Short circuit protection continuous, automatic recovery TEN 50-4810WI 3.3 VDC 10000 mA Efficiency 91 % typ. TEN 50-4811WI 5 VDC 10000 mA Operating temperature –40 °C to +80 °C TEN 50-4812WI 18 – 75 VDC 12 VDC 4170 mA range above 55 °C derating 2.0 %/K TEN 50-4813WI 15 VDC 3330 mA I/O isolation voltage 1500 VDC (60 sec.) TEN 50-4815WI 24 VDC 2080 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report Optional heatsink: TEN-HS4 approvals Remote On/Off shutdown input for low input current (2.5 mA) in standby operation Casing metal, with insulated baseplate Full datasheet www.tracopower.com/products/ten50wi.pdf Dimensions Pin Single output 15.24 (0.6) 1 + Vin (Vcc) 5.08 2.54 (0.2) (0.1) 2 – Vin (GND) 5.08 (0.2) 3 Remote On/Off 4 + Vout 3 2 1 5 – Vout 6 Trim Bottom View 6 5 4 5.1 10.16 (0.20) (0.4) 10.2 20.32 (0.4) (0.8) 25.4 (1.0) () = Inches 96 NEW Product 45.72 (1.8) 2.5 (0.1) 50.8 (2.0) www.tracopower.com High Performance DC/DC Converters CB CB TEN-60N Series 60 W Schem Schemee UL 60950-1 Highest power density 60 W converter 6-sied shielded metal casing 2“ x 1“ x 0.4“ metal package Wide 2:1 input range Highest efficiency up to 92 % High efficiency across load range Operating temperature range –40 °C to +70 °C Low no-load current I/O isolation 1500 VDC Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation 1.0 % max. TEN 60-1211N 5.0 VDC 12000 mA Output voltage ±10 % by external resistor TEN 60-1212N 12 VDC 5000 mA adjustment 15 & 24 VDC models: +20/-10 % TEN 60-1213N 9 – 18 VDC 15 VDC 4000 mA Input current at no load 10mA typ. TEN 60-1215N 24 VDC 2500 mA Ripple & noise – 24 VDC output models: <200 mVpk-pk TEN 60-1222N ± 12 VDC ± 2500 mA (20 MHz BW) – other output models: <125 mVpk-pk TEN 60-1223N ± 15 VDC ± 2000 mA Conducted EMI EN 55022, class EN55022 class A TEN 60-2411N 5.0 VDC 12000 mA (with external components) TEN 60-2412N 12 VDC 5000 mA Short circuit protection continuous, automatic recovery TEN 60-2413N 18 – 36 VDC 15 VDC 4000 mA Efficiency 91 % typ. TEN 60-2415N 24 VDC 2500 mA Operating temperature –40 °C to 70 °C TEN 60-2422N ± 12 VDC ± 2500 mA range above 40 °C derating 1.7 %/K TEN 60-2423N ± 15 VDC ± 2000 mA I/O isolation voltage 1500 VDC (60 sec.) TEN 60-4811N 5.0 VDC 12000 mA TEN 60-4812N 12 VDC 5000 mA Safety standards / cUL /UL 60950-1, IEC/EN 60950-1, CB-report approvals TEN 60-4813N 36 – 75 VDC 15 VDC 4000 mA TEN 60-4815N 24 VDC 2500 mA Remote On/Off shutdown input for low input current (2.5 mA) in standby operation TEN 60-4822N ± 12 VDC ± 2500 mA TEN 60-4823N ± 15 VDC ± 2000 mA Casing 6-side shielded metal case with insulated baseplate Full datasheet www.tracopower.com/products/ten60n.pdf Dimensions Pin Single output Dual output 15.24 (0.6) 1 + Vin (Vcc) + Vin (Vcc) 5.08 2.54 (0.2) (0.1) 2 – Vin (GND) – Vin (GND) 5.08 (0.2) 3 Remote On/Off Remote On/Off 4 + Vout + Vout 3 2 1 5 – Vout Common 6 Trim – Vout Bottom View 6 5 4 5.1 10.16 (0.20) (0.4) 10.2 20.32 (0.4) (0.8) 25.4 (1.0) () = Inches 97 NEW Product 45.72 (1.8) 2.5 (0.1) 50.8 (2.0) www.tracopower.com DC/DC Converters High Performance CB CB TEN-60WIN Series 60 W Schem Schemee UL 60950-1 Highest power density 60 W converter 6-sied shielded metal casing 2“ x 1“ x 0.4“ metal package Ultra wide 4:1 input range Highest efficiency up to 92 % High efficiency across load range Operating temperature range –40 °C to +70 °C Low no-load current I/O isolation 1500 VDC Remote On/Off Adjustable output voltage Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2 % max. max. Load regulation 1.0 % max. TEN 60-2411WIN 5.0 VDC 12000 mA Output voltage ±10 % by external resistor TEN 60-2412WIN 12 VDC 5000 mA adjustment 15 & 24 VDC models: +20/-10 % TEN 60-2413WIN 9 – 36 VDC 15 VDC 4000 mA Ripple & noise – 24 VDC output models: <200 mVpk-pk TEN 60-2415WIN 24 VDC 2500 mA (20 MHz BW) – other output models: <125 mVpk-pk TEN 60-2422WIN ± 12 VDC ± 2500 mA Conducted EMI EN 55022, class EN55022 class A TEN 60-2423WIN ± 15 VDC ± 2000 mA (with external components) TEN 60-4811WIN 5.0 VDC 12000 mA Short circuit protection continuous, automatic recovery TEN 60-4812WIN 12 VDC 5000 mA Efficiency 91 % typ. TEN 60-4813WIN 18 – 75 VDC 15 VDC 4000 mA Operating temperature –40 °C to +70 °C TEN 60-4815WIN 24 VDC 2500 mA range above 42 °C derating 1.7 %/K TEN 60-4822WIN ± 12 VDC ± 2500 mA I/O isolation voltage 1500 VDC (60 sec.) TEN 60-4823WIN ± 15 VDC ± 2000 mA Safety standards / cUL /UL 60950-1, IEC/EN 60950-1, CB-report approvals Remote On/Off shutdown input for low input current (2.5 mA) in standby operation Casing 6-side shielded metal case with insulated baseplate Full datasheet www.tracopower.com/products/ten60win.pdf Dimensions Pin Single output Dual output 15.24 (0.6) 1 + Vin (Vcc) + Vin (Vcc) 5.08 2.54 (0.2) (0.1) 2 – Vin (GND) – Vin (GND) 5.08 (0.2) 3 Remote On/Off Remote On/Off 4 + Vout + Vout 3 2 1 5 – Vout Common 6 Trim – Vout Bottom View 6 5 4 5.1 10.16 (0.20) (0.4) 10.2 20.32 (0.4) (0.8) 25.4 (1.0) () = Inches 98 NEW Product 45.72 (1.8) 2.5 (0.1) 50.8 (2.0) www.tracopower.com Chassis Mount DC/DC Converters CB TMDC-60 Series 60 W Scheme UL 60950-1 Fully encapsulated low profile plastic casing Ultra wide 4:1 input voltage range Operating temperature range –40°C to +80°C Highest efficiency up to 91 % I/O isolation 2500 VDC Remote On/Off Power-good LED indicator Reverse input protection Optional DIN-rail mount adapter Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5% max. max. Load regulation 1.0% max. TMDC 60-2411 5.1 VDC 12000 mA Ripple & noise 5.1 VDC modesl: <100 mVpk-pk (20 MHz BW) TMDC 60-2412 9 – 36 VDC 12 VDC 5000 mA 12 & 24 VDC modesl: <150 mVpk-pk (20 MHz BW) TMDC 60-2415 24 VDC 2500 mA 48 VDC modesl: <200 mVpk-pk (20 MHz BW) TMDC 60-2418 48 VDC 1250 mA Conducted EMI EN 55022, class EN55022 class A TMDC 60-4811 5.1 VDC 12000 mA Short circuit protection continuous, automatic recovery TMDC 60-4812 18 – 75 VDC 12 VDC 5000 mA Efficiency 90% typ. TMDC 60-4815 24 VDC 2500 mA Operating temperature –40 °C to +80 °C TMDC 60-4818 48 VDC 1250 mA range above 70 °C derating 3.3 %/K I/O isolation voltage 2500 VDC (60 sec.) reinforced insulation Safety standards cUL/UL 60950-1, IEC/EN 60950-1 (reports pending) Remote On/Off shutdown input for low current in standby operation Casing metal, with insulated baseplate Full datasheet www.tracopower.com/products/tmdc60.pdf Dimensions DIN-rail mount adapter TMP-MK2 Type Length l Width w Height h TMDC 60-xxxx 112 (4.41) 67.8 (2.67) 38.0 (1.50) l () = Inches 99 NEW Product w h www.tracopower.com DC/DC Converters High Power Modules TEP-75WI Series 75 W UL 60950-1 Rugged compact metal casing Ultra wide 4:1 input voltage range up to 160 VDC Very high efficiency up to 90 % Operating temperature range –40 °C to +85 °C Certified for railway applications EN 50155 Input under voltage lockout Reverse input protection I/O isolation 2250 VDC Adjustable output voltage Optional chassis mount adapter with screw terminal and (Models pictured with chassis mount adapter and heat-sink) adapter for DIN-rail mount Specifications Models Line regulation 0.2% max. Order code Input voltage Output voltage Output current max. Load regulation 0.3% max. TEP 75-2411WI 5.0 VDC 15.0 A Output voltage +10% / -20% adjustable by external resistor TEP 75-2412WI 12 VDC 6.3 A Ripple & noise <1 % of Vout (20 MHz BW) TEP 75-2413WI 9 – 36 VDC 15 VDC 5.0 A EMC - Conducted noise: EN 55022, class EN55022 class A (with TEP 75-2415WI 24 VDC 3.2 A CMF option). On request: Common mode chokes for filter TEP 75-2416WI 28 VDC 2.7 A proposals to meet EN55022 class A/B TEP 75-2418WI 48 VDC 1.6 A - Immunity: EN 50155 TEP 75-4811WI 5.0 VDC 15.0 A Short circuit protection continuous, automatic recovery TEP 75-4812WI 12 VDC 6.3 A Reverse input protection parallel diode TEP 75-4813WI 18 – 75 VDC 15 VDC 5.0 A Efficiency 88 % typ. TEP 75-4815WI 24 VDC 3.2 A Operating temperature –40 °C to +85°C with heat-sink TEP 75-4816WI 28 VDC 2.7 A range for derating see datasheet TEP 75-4818WI 48 VDC 1.6 A Thermal protection shutdown at 115 °C TEP 75-7211WI 5.0 VDC 15.0 A I/O isolation voltage 2250 VDC (60 sec.), basic insulation TEP 75-7212WI 12 VDC 6.3 A Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, EN50155 TEP 75-7213WI 43 –160 VDC 15 VDC 5.0 A approvals TEP 75-7215WI 24 VDC 3.2 A Remote On/Off shutdown input for low input current (3 mA) TEP 75-7216WI 28 VDC 2.7 A in standby operation TEP 75-7218WI 48 VDC 1.6 A Thermal shock and EN 61373 / MIL-STD-810F Options shock & vibration Heat-sink: TEP-HS1 (separate part, assembling on demand) Full datasheet www.tracopower.com/products/tep75wi.pdf Chassis mount adapter with EMI-filter: add suffix -CMF* DIN-rail mounting clip for chassis mount versions: TEP-MK1 Dimensions * Shipped assembled with converter module TEP 75WI Module TEP 75WI Module with heat-sink On demand: 0.19 (4.8) 1.90 (48.26) 0.20 0.5 0.20 0.95 (5.1) (12.7) (5.1) (24.2) Modules with output voltages of 3.3 VDC 4 x M3 THD Common mode chokes for filter proposals to meet EN55022 class A/B (trough hole) 1 5 2 6 Bottom view 7 3 8 4 9 Pin TEP 75WI Module on 1 – Vin (GND) Chassis mount adapter with EMI-filter 2 Case 1.53 (38.8) 0.89 (22.2) 1.60 (40.6) 3 Remote On/Off 4 + Vin (Vcc) 5 – Vout 6 – Sense 7 Trim 8 + Sense 9 + Vout 3.071 (78.0) 0.14 (3.5) 3.35 (85.0) () = mm 100 2.00 (50.8) 2.40 (61.0) 2.00 (50.80) 2.40 (61.0) 0.14 2.126 (54.0) (3.5) 0.30 (7.62) 0.70 (17.78) 1.00 (25.40) 4 x Ø 0.17 (4.3) www.tracopower.com www.tracopower.com High Power Modules High Power Modules DC/DC Converters DC/DC Converters TEP-100 Series 100 W UL 60950-1 Rugged compact metal casing Wide 2:1 input voltage range Excellent efficiency up to 93 % Operating temperature range –40 °C to +85 °C Input under voltage lockout Reverse input protection I/O isolation 2250 VDC Adjustable output voltage Optional chassis mount adapter with screw terminal and adapter for DIN-rail mount (Models pictured with chassis mount adapter and heat-sink) Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2% max. max. Load regulation 0.3% max. TEP 100-1210 3.3 VDC 25.0 A Output voltage adjustmt +10 % / -20% adjustable by external resistor TEP 100-1211 5.0 VDC 20.0 A Ripple & noise – 5 VDC output models: <75 mVpk-pk TEP 100-1212 12 VDC 8.4 A (20 MHz BW) – other output models: <1 % of Vout TEP 100-1213 9 – 18 VDC 15 VDC 6.7 A Conducted EMI EN 55022, class EN55022 class A (with CMF option) TEP 100-1215 24 VDC 4.2 A On request: Common mode chokes for filter proposals to TEP 100-1216 28 VDC 3.6 A meet EN55022 class A/B TEP 100-1218 48 VDC 2.1 A Short circuit protection continuous, automatic recovery TEP 100-2410 3.3 VDC 25.0 A Reverse input protection parallel diode TEP 100-2411 5.0 VDC 20.0 A Efficiency 92 % typ. TEP 100-2412 12 VDC 8.4 A TEP 100-2413 18 – 36 VDC 15 VDC 6.7 A Operating temperature –40 °C to +85 °C (with heat-sink) range for derating see datasheet TEP 100-2415 24 VDC 4.2 A TEP 100-2416 28 VDC 3.6 A Thermal protection shutdown at 115 °C TEP 100-2418 48 VDC 2.1 A I/O isolation voltage 2250 VDC (60 sec.), basic insulation TEP 100-4810 3.0 VDC 25.0 A Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 TEP 100-4811 5.0 VDC 20.0 A approvals TEP 100-4812 12 VDC 8.4 A Remote On/Off shutdown input for low input current (3 mA) TEP 100-4813 36 – 75 VDC 15 VDC 6.7 A in standby operation TEP 100-4815 24 VDC 4.2 A Casing shielded metal case with aluminium baseplate TEP 100-4816 28 VDC 3.6 A Full datasheet www.tracopower.com/products/tep100.pdf TEP 100-4818 48 VDC 2.1 A Dimensions Options Heat-sink: TEP-HS1 (separate part, assembling on demand) TEP 100 Module TEP 100 Module with Heat-sink Chassis mount adapter with EMI-filter: add suffix -CMF* 0.20 0.5 0.20 0.95 0.19 (4.8) 1.90 (48.26) (5.1) (12.7) (5.1) (24.2) DIN-rail mounting clip for chassis mount versions: TEP-MK1 4 x M3 THD * Shipped assembled with converter module (trough hole) 1 5 On demand: Common mode chokes for filter proposals to meet EN55022 class A/B 2 6 Bottom view 7 3 8 4 9 Pin 1 – Vin (GND) TEP 100 Module on TEP 100 Module on Chassis mount adapter Chassis mount adapter with EMI-filter 2 Case 1.53 (38.8) 3 Remote On/Off 0.89 (22.2) 1.60 (40.6) 4 + Vin (Vcc) 5 – Vout 6 – Sense 7 Trim 8 + Sense 9 + Vout 3.071 (78.0) 0.14 (3.5) 3.35 (85.0) () = mm 101 2.00 (50.8) 2.40 (61.0) 2.00 (50.80) 2.40 (61.0) 0.14 2.126 (54.0) (3.5) 0.30 (7.62) 0.70 (17.78) 1.00 (25.40) 4 x Ø 0.17 (4.3) www.tracopower.com DC/DC Converters High Power Modules TEP-100WIR Series 100 W UL 60950-1 High power density Ultra wide 4:1 input voltage range up to 160 VDC Very high efficiency up to 92 % Certified for railway applications EN 50155 Over temperatur protection Input under voltage lockout Reverse input protection I/O isolation 2250 VDC Adjustable output voltage Shielded metal case with aluminium baseplate (Model pictured with mounted heat-sink) Specifications Specifications Models Models Order code Input voltage Output voltage Output current Line regulation 0.1% max. max. Load regulation 0.1 % max. TEP 100-2412WIR 12 VDC 8.4 A Output voltage +10 % / -20 % adjustable by external resistor TEP 100-2415WIR 8.5 – 36 VDC 24 VDC 4.2 A Ripple & noise <1 % of Vout TEP 100-2416WIR 28 VDC 3.6 A (20 MHz BW) TEP 100-2418WIR 48 VDC 2.1 A EMC - Conducted noise: Common mode chokes for filter TEP 100-4812WIR 12 VDC 8.4 A proposals to meet EN55022 class A/B on demand TEP 100-4815WIR 16.5 – 75 VDC 24 VDC 4.2 A - Immunity: EN50155 TEP 100-4816WIR 28 VDC 3.6 A Short circuit protection continuous, automatic recovery TEP 100-4818WIR 48 VDC 2.1 A Reverse input protection parallel diode TEP 100-7212WIR 12 VDC 8.4 A Efficiency 90 % typ. TEP 100-7215WIR 43 – 160 VDC 24 VDC 4.2 A Operating temperature –40 °C to +75°C with heat-sink TEP 100-7216WIR 28 VDC 3.6 A range for derating see datasheet TEP 100-7218WIR 48 VDC 2.1 A Thermal protection shutdown at 120 °C Options Heat-sink: TEP-HS1 (separate part, assembling on demand) I/O isolation voltage 2250 VDC (60 sec.), basic insulation Chassis mount adapter with EMI-filter: add suffix -CMF* Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, EN 50155, (reports pending) DIN-rail mounting clip for chassis mount versions: TEP-MK1 approvals * Shipped assembled with converter module Thermal shock and EN 61373 / MIL-STD-810F On demand: shock & vibration Modules with output voltages of 3.3 VDC Remote On/Off shutdown input for low input current (3 mA) Common mode chokes for filter proposals to meet EN55022 class A/B in standby operation Full datasheet www.tracopower.com/products/tep100wir.pdf Dimensions TEP 100WIR Modul TEP 100WIR Module with heat-sink Pin 1 – Vin (GND) 2.28 (57.91) 2 Case 0.19 (4.8) 1.90 (48.26) 0.20 0.5 0.20 0.95 3 Remote On/Off (5.1) (12.7) (5.1) (24.2) 4 + Vin (Vcc) 4 x M3 THD (trough hole) 5 – Vout 1 5 6 – Sense 2 6 7 Trim Bottom view 7 8 + Sense 3 8 9 + Vout 4 9 () = mm 102 1.10 (28.0) 1.18 (30.0) 1.02 (25.9) 1.31 (33.3) 3.071 (78.0) 0.14 (3.5) 3.35 (85.0) NEW Product 1.90 (48.3) 2.40 (61.0) 2.40 (61.0) 0.14 2.126 (54.0) 2.00 (50.80) (3.5) 0.30 (7.62) 0.70 (17.78) 1.00 (25.40) 4 x Ø 0.17 (4.3) www.tracopower.com High Power Modules DC/DC Converters CB TEQ-100WIR Series 100 W UL 60950-1 Scheme UL 508 High power block with excellent thermal convection Operating temperature –40°C up to +85°C without derating! Increased shock & vibration resistance Ultra wide 4:1 input voltage range up to 160 VDC Certified for railway applications EN 50155 UL 508 approval Excellent efficiency up to 90% Low no-load input current Input filter to meet EN 55022, class A I/O isolation 2250 VDC Input undervoltage-lockout circuit Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.1% max. max. Load regulation 0.1 % max. TEQ 100-2412WIR 12 VDC 8.4 A Output voltage +10 % / -20 % adjustable by external resistor TEQ 100-2415WIR 8.5 – 36 VDC 24 VDC 4.2 A Ripple & noise <1 % of Vout TEQ 100-2416WIR 28 VDC 3.6 A (20 MHz BW) TEQ 100-2418WIR 48 VDC 2.1 A EMC - Conducted noise: EN55022 class A TEQ 100-4812WIR 12 VDC 8.4 A - Immunity: EN50155 TEQ 100-4815WIR 16.5 – 75 VDC 24 VDC 4.2 A Short circuit protection continuous, automatic recovery TEQ 100-4816WIR 28 VDC 3.6 A Reverse input protection parallel diode TEQ 100-4818WIR 48 VDC 2.1 A TEQ 100-7212WIR 12 VDC 8.4 A Efficiency 90 % typ. TEQ 100-7215WIR 43 – 160 VDC 24 VDC 4.2 A Operating temperature –40 °C to +85°C without derating range up to +105°C with derating TEQ 100-7216WIR 28 VDC 3.6 A TEQ 100-7218WIR 48 VDC 2.1 A Thermal protection shutdown at 120 °C I/O isolation voltage 2250 VDC (60 sec.), basic insulation Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, EN 50155, UL508 approvals Thermal shock and EN 61373 / MIL-STD-810F shock & vibration Remote On/Off shutdown input for low input current (3 mA) in standby operation Full datasheet www.tracopower.com/products/teq100wir.pdf Dimensions Pin 1 – Vin (GND) 103.2 (4.06) 2 – Vin (GND) 87.6 (3.45) 74.2 (2.92) 3 No con. 4 Remote On/Off 5 + Vin 6 + Vin 7 – Vout 8 – Vout 9 – Sense 10 + Sense 11 + Vout 3.2 (0.13) 12 + Vout () = Inches 103 NEW Product 88.9 (3.5) 76.2 (3.0) 79.1 (3.11) www.tracopower.com DC/DC Converters High Power Modules CB CB TEP-150WI Series 150 W Schem Schemee UL 60950-1 Highest power density Wide 4:1 input voltage range Over temperatur protection Constant current characteristic at 100 % load for battery load applications Certified for railway applications EN 50155 Input under voltage lockout Operating temperature range –40 °C to +75 °C Reverse input protection I/O isolation 2250 VDC (basic insulation) Easy chassis and wall mounting Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2% max. max. Load regulation 0.4 % max. TEP 150-2412WI 12 VDC 12.5 A Output voltage +20 % by external resistor TEP 150-2413WI 15 VDC 10.0 A adjustment TEP 150-2415WI 9 – 36 VDC 24 VDC 6.3 A Ripple & noise <1 % of Vout TEP 150-2416WI 28 VDC 5.4 A (20 MHz BW) TEP 150-2418WI 48 VDC 3.2 A EMC EN 55022, class EN55022 class A TEP 150-4812WI 12 VDC 12.5 A EN 55022, class B with filter module (suffix -F) TEP 150-4813WI 15 VDC 10.0 A EN 50155 TEP 150-4815WI 18 – 75 VDC 24 VDC 6.3 A Short circuit protection continuous, automatic recovery TEP 150-4816WI 28 VDC 5.4 A Over-temperature switch off at over-temperature, automatic restart. TEP 150-4818WI 48 VDC 3.2 A protection TEP 150-7212WI 12 VDC 12.5 A Reverse input protection parallel diode TEP 150-7213WI 15 VDC 10.0 A Efficiency 86 % typ. TEP 150-7215WI 43 – 160 VDC 24 VDC 6.3 A Operating temperature –40 °C to +75 °C TEP 150-7216WI 28 VDC 5.4 A range for derating see datasheet TEP 150-7218WI 48 VDC 3.2 A I/O isolation voltage 2250 VDC (60 sec.), basic insulation Safety standards cUL/UL 60950-1, IEC/EN 60950-1, EN 50155, CB test report Modules with input filter to meet Remote On/Off shutdown input for low input current (3 mA) EN 55022 class B. Add suffix -F in standby operation (passive input = On) On demand: reverse function (passive input = off) Casing shielded metal case, IP55 Full datasheet www.tracopower.com/products/tep150wi.pdf Dimensions Dimensions Con. 1 + Vin (Vcc) 98.0 (3.86) 2 + Vin (Vcc) 34.0 (1.34) 1.2 (0.05) 21.0 (0.83) 56.0 (2.20) 3 – Vin (GND) 4 – Vin (GND) 5 Remote On/Off 6 + Vout 7 – Vout 8 Trim 9 Trim () = Inches 104 NEW Models 52.5 (2.07) 1 2 3 4 5 6 7 8 9 65.0 (2.56) 59.0 (2.07) 4 x r2 (0.08) www.tracopower.com High Power Modules DC/DC Converters TEP-160 Series 150 to 196 W UL 60950-1 High power density Wide 2:1 input voltage range Excellent efficiency up to 93 % Over temperatur protection Input under voltage lockout Reverse input protection I/O isolation 2250 VDC (basic insulation) Adjustable output voltage Shielded metal case with aluminium baseplate (Model pictured with mounted heat-sink) Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2% max. max. Load regulation 0.3 % max. TEP 160-2412 12 VDC 13 A Output voltage +10 % / -20 % adjustable by external resistor TEP 160-2413 15 VDC 10 A Ripple & noise – 5 VDC output models: <75 mVpk-pk TEP 160-2415 16.5 – 36 VDC 24 VDC 6.5 A (20 MHz BW) – other output models: <1 % of Vout TEP 160-2416 28 VDC 5.5 A Short circuit protection continuous, automatic recovery TEP 160-2418 48 VDC 3.3 A Reverse input protection parallel diode TEP 160-4812 12 VDC 16 A Efficiency 90% typ. TEP 160-4813 15 VDC 13 A TEP 160-4815 33 – 75 VDC 24 VDC 8 A Operating temperature –40 °C to +75°C, for derating see datasheet TEP 160-4816 28 VDC 7 A range TEP 160-4818 48 VDC 4 A Thermal protection shutdown at 115 °C TEP 160-48153 53 VDC 3.7 A I/O isolation voltage 2250 VDC (60 sec.), basic insulation Options: Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 Heat-sink: TEP-HS1 (separate part, factory assembling on demand) approvals On demand: Remote On/Off shutdown input for low input current (3 mA) Modules with input voltage range of 8.5 - 22 VDC in standby operation Modules with output voltages of 3.3 or 5.0 VDC Full datasheet www.tracopower.com/products/tep160.pdf Common mode chokes for filter proposals to meet EN55022 class A/B Dimensions Pin TEP 160 Module TEP 160 Module with heat-sink 1 – Vin (GND) 2 Case 3 Remote On/Off 2.28 (57.91) 4 + Vin (Vcc) 0.19 (4.8) 1.90 (48.26) 0.20 0.5 0.20 0.95 (5.1) (12.7) (5.1) (24.2) 5 – Vout 4 x M3 THD 6 – Sense (trough hole) 1 5 7 Trim 8 + Sense 2 6 Bottom view 9 + Vout 7 3 8 4 9 () = mm 105 1.10 (28.0) 1.18 (30.0) 1.02 (25.9) 1.31 (33.3) 3.071 (78.0) 0.14 (3.5) 3.35 (85.0) 1.90 (48.3) 2.40 (61.0) 2.40 (61.0) 0.14 2.126 (54.0) 2.00 (50.80) (3.5) 0.30 (7.62) 0.70 (17.78) 1.00 (25.40) 4 x Ø 0.17 (4.3) www.tracopower.com DC/DC Converters High Power Modules TEP-160WIR Series 144 to 182 W UL 60950-1 High power density Ultra wide 4:1 input voltage range up to 160 VDC Very high efficiency up to 91 % Certified for railway applications EN 50155 Over temperatur protection Input under voltage lockout Reverse input protection I/O isolation 2250 VDC (basic insulation) Adjustable output voltage Shielded metal case with aluminium baseplate (Model pictured with mounted heat-sink) Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2% max. max. Load regulation 0.25 % max. TEP 160-2412WIR 12 VDC 12 A Output voltage +10 % / -20 % adjustable by external resistor TEP 160-2413WIR 15 VDC 9.5 A Ripple & noise <1 % of Vout TEP 160-2415WIR 8.5 – 36 VDC 24 VDC 6.0 A (20 MHz BW) TEP 160-2416WIR 28 VDC 5.0 A EMC - Conducted noise: Common mode chokes for filter TEP 160-2418WIR 48 VDC 3.0 A proposals to meet EN55022 class A/B on demand TEP 160-4812WIR 12 VDC 13 A - Immunity: EN50155 TEP 160-4813WIR 15 VDC 10 A Short circuit protection continuous, automatic recovery TEP 160-4815WIR 16.5 – 75 VDC 24 VDC 6.5 A Reverse input protection parallel diode TEP 160-4816WIR 28 VDC 5.5 A Efficiency 88 % typ. TEP 160-4818WIR 48 VDC 3.2 A Operating temperature –40 °C to +75°C with heat-sink TEP 160-7212WIR 12 VDC 15 A range for derating see datasheet TEP 160-7213WIR 15 VDC 12 A Thermal protection shutdown at 120 °C TEP 160-7215WIR 43 – 160 VDC 24 VDC 7.5 A TEP 160-7216WIR 28 VDC 6.5 A I/O isolation voltage 2250 VDC (60 sec.), basic insulation TEP 160-7218WIR 48 VDC 3.8 A Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, EN 50155 Options: approvals Heat-sink: TEP-HS1 (separate part, factory assembling on demand) Thermal shock and EN 61373 / MIL-STD-810F On demand: shock & vibration Modules with output voltages of 3.3 or 5.0 VDC Remote On/Off shutdown input for low input current (3 mA) Adapter for Chassis mount and DIN-rail mount (with screw terminal) in standby operation Chassis mount models with input filter to meet EN 555022 class A Full datasheet www.tracopower.com/products/tep160wir.pdf Common mode chokes for filter proposals to meet EN55022 class A/B Dimensions TEP 160WIR Module TEP 160WIR Module with heat-sink Pin 1 – Vin (GND) 2.28 (57.91) 2 Case 0.20 0.5 0.20 0.95 0.19 (4.8) 1.90 (48.26) (5.1) (12.7) (5.1) (24.2) 3 Remote On/Off 4 x M3 THD 4 + Vin (Vcc) (trough hole) 1 5 5 – Vout 6 – Sense 2 6 Bottom view 7 Trim 7 8 + Sense 3 8 9 + Vout 4 9 () = mm 106 1.10 (28.0) 1.18 (30.0) 1.02 (25.9) 1.31 (33.3) 3.071 (78.0) 0.14 (3.5) 3.35 (85.0) 1.90 (48.3) 2.40 (61.0) 2.40 (61.0) 0.14 2.126 (54.0) 2.00 (50.80) (3.5) 0.30 (7.62) 0.70 (17.78) 1.00 (25.40) 4 x Ø 0.17 (4.3) www.tracopower.com High Power Modules DC/DC Converters CB UL 60950-1 TEQ-160WIR Series 156 to 182 W Scheme UL 508 High power block with excellent thermal convection Operating temperature –40°C up to +75°C without derating! Increased shock & vibration resistance Ultra wide 4:1 input voltage range up to 160 VDC Certified for railway applications EN 50155 UL 508 approval Excellent efficiency up to 90% Low no-load input current Input filter to meet EN 55022, class A I/O isolation 2250 VDC Inout undervoltage-lockout circuit Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.1% max. max. Load regulation 0.1 % max. TEQ 160-4812WIR 12 VDC 13 A Output voltage +10 % / -20 % adjustable by external resistor TEQ 160-4815WIR 18 – 75 VDC 24 VDC 6.5 A Ripple & noise <1 % of Vout TEQ 160-4816WIR 28 VDC 5.5 A (20 MHz BW) TEQ 160-4818WIR 48 VDC 3.2 A EMC - Conducted noise: EN55022 class A TEQ 160-7212WIR 12 VDC 15 A - Immunity: EN50155 TEQ 160-7215WIR 43 – 160 VDC 24 VDC 7.5 A Short circuit protection continuous, automatic recovery TEQ 160-7216WIR 28 VDC 6.5 A Reverse input protection parallel diode TEQ 160-7218WIR 48 VDC 3.8 A Efficiency 89 % typ. Operating temperature –40 °C to +75°C without derating range up to +105°C with derating Thermal protection shutdown at 120 °C I/O isolation voltage 2250 VDC (60 sec.), basic insulation Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, EN 50155, UL508 approvals Thermal shock and EN 61373 / MIL-STD-810F shock & vibration Remote On/Off shutdown input for low input current (3 mA) in standby operation Full datasheet www.tracopower.com/products/teq160wir.pdf Dimensions Pin 1 – Vin (GND) 103.2 (4.06) 2 – Vin (GND) 87.6 (3.45) 74.2 (2.92) 3 No con. 4 Remote On/Off 5 + Vin 6 + Vin 7 – Vout 8 – Vout 9 – Sense 10 + Sense 11 + Vout 3.2 (0.13) 12 + Vout () = Inches 107 NEW Product 88.9 (3.5) 76.2 (3.0) 79.1 (3.11) www.tracopower.com DC/DC Converters High Power Modules TEP-200WIR Series 180 to 240 W pending Chassis mount converter with screw terminal Ultra wide 4:1 input voltage range EMI filter to meet EN 55022 class A Very high efficiency up to 91 % Certified for railway applications EN 50155 Input under voltage lockout Over temperatur protection Reverse input protection I/O isolation 2250 VDC Adjustable output voltage Low no-load input current Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.2% max. max. Load regulation 0.3 % max. TEP 200-2412WIRCMF 12 VDC 15 A Output voltage +10 % / -20 % adjustable by external resistor TEP 200-2413WIRCMF 15 VDC 12 A Ripple & noise <1 % of Vout (20 MHz BW) TEP 200-2415WIRCMF 8.5 – 36 VDC 24 VDC 7.5 A EMC - Conducted noise: EN55022 class A TEP 200-2416WIRCMF 28 VDC 6.5 A - Immunity: EN50155 TEP 200-2418WIRCMF 48 VDC 3.7 A Short circuit protection continuous, automatic recovery TEP 200-4812WIRCMF 12 VDC 18 A Reverse input protection parallel diode TEP 200-4813WIRCMF 15 VDC 14 A TEP 200-4815WIRCMF 16.5 – 75 VDC 24 VDC 9.0 A Efficiency 90 % typ. TEP 200-4816WIRCMF 28 VDC 7.5 A Operating temperature –40 °C to +75°C with heat-sink TEP 200-4818WIRCMF 48 VDC 4.5 A range for derating see datasheet TEP 200-7212WIRCMF 12 VDC 20 A Thermal protection shutdown at 120 °C TEP 200-7213WIRCMF 15 VDC 16 A I/O isolation voltage 2250 VDC (60 sec.), basic insulation TEP 200-7215WIRCMF 43 – 160 VDC 24 VDC 10 A Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, EN 50155 TEP 200-7216WIRCMF 28 VDC 8.5 A approvals TEP 200-7218WIRCMF 48 VDC 5 A Thermal shock and EN 61373 / MIL-STD-810F On demand shock & vibration Models with 3.3 VDC or 5.0 VDC output Remote On/Off shutdown input for low input current (3 mA) Models with 53 VDC output (input voltage range 33 - 75 VDC) in standby operation Negative (passive = Off) Remote On/Off function (standard is passive = On) Full datasheet www.tracopower.com/products/tep200wir.pdf 0.20 0.5 0.20 0.95 0.19 (4.8) 1.90 (48.26) (5.1) (12.7) (5.1) (24.2) 4 x M3 THD (trough hole) 1 5 2 6 Bottom view 7 3 8 4 9 Dimensions Pin 1 – Vin (GND) 1.53 (38.8) 2 Case 0.89 (22.2) 1.60 (40.6) 3 Remote On/Off 4 + Vin (Vcc) 5 – Vout 6 – Sense 7 Trim 8 + Sense 9 + Vout 3.071 (78.0) 0.14 (3.5) 3.35 (85.0) () = mm 108 2.00 (50.8) 2.40 (61.0) 2.00 (50.80) 2.40 (61.0) 0.14 2.126 (54.0) (3.5) 0.30 (7.62) 0.70 (17.78) 1.00 (25.40) 4 x Ø 0.17 (4.3) www.tracopower.com High Power Modules DC/DC Converters CB UL 60950-1 TEQ-200WIR Series 216 to 240 W Scheme UL 508 High power block with excellent thermal convection Operating temperature –40°C up to +70°C without derating! Increased shock & vibration resistance Ultra wide 4:1 input voltage range up to 160 VDC Certified for railway applications EN 50155 UL 508 approval Excellent efficiency up to 90% Low no-load input current Input filter to meet EN 55022, class A I/O isolation 2250 VDC Inout undervoltage-lockout circuit Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.1% max. max. Load regulation 0.1 % max. TEQ 200-4812WIR 12 VDC 18 A Output voltage +10 % / -20 % adjustable by external resistor TEQ 200-4815WIR 18 – 75 VDC 24 VDC 9.0 A Ripple & noise <1 % of Vout TEQ 200-4816WIR 28 VDC 7.5 A (20 MHz BW) TEQ 200-4818WIR 48 VDC 4.5 A EMC - Conducted noise: EN55022 class A TEQ 200-7212WIR 12 VDC 20 A - Immunity: EN50155 TEQ 200-7215WIR 43 – 160 VDC 24 VDC 10 A Short circuit protection continuous, automatic recovery TEQ 200-7216WIR 28 VDC 8.5 A Reverse input protection parallel diode TEQ 200-7218WIR 48 VDC 5.0 A Efficiency 89 % typ. Operating temperature –40 °C to +70°C without derating range above 70°C derating 3%/K Thermal protection shutdown at 120 °C I/O isolation voltage 2250 VDC (60 sec.), basic insulation Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, EN 50155, UL508 approvals Thermal shock and EN 61373 / MIL-STD-810F shock & vibration Remote On/Off shutdown input for low input current (3 mA) in standby operation Full datasheet www.tracopower.com/products/teq200wir.pdf Dimensions Pin 1 – Vin (GND) 103.2 (4.06) 2 – Vin (GND) 87.6 (3.45) 74.2 (2.92) 3 No con. 4 Remote On/Off 5 + Vin 6 + Vin 7 – Vout 8 – Vout 9 – Sense 10 + Sense 11 + Vout 3.2 (0.13) 12 + Vout () = Inches 109 NEW Product 88.9 (3.5) 76.2 (3.0) 79.1 (3.11) Ø5.2 (Ø 0.2) www.tracopower.com DC/DC Converters High Power Modules CB UL 60950-1 TEQ-300WIR Series 300 W Scheme UL 508 High power block with excellent thermal convection Operating temperature –40°C up to +55°C without derating! Increased shock & vibration resistance Ultra wide 4:1 input voltage range Certified for railway applications EN 50155 Excellent efficiency up to 90% Input filter to meet EN 55022, class A I/O isolation 3000 VDC Undervoltage lockout circuit Soft start Constant current characteristic at 100 % load Specifications Specifications Models Models Order code Input voltage Output voltage Output current Line regulation 0.1% max. max. Load regulation 0.1 % max. TEQ 300-4812WIR 12 VDC 25 A Output voltage +10 % / -20 % adjustable by external resistor TEQ 300-4815WIR 18 – 75 VDC 24 VDC 12.5 A Ripple & noise <1 % of Vout TEQ 300-4816WIR 28 VDC 11 A (20 MHz BW) TEQ 300-4818WIR 48 VDC 6.5 A EMC - Conducted noise: EN55022 class A TEQ 300-7212WIR 12 VDC 27 A - Immunity: EN50155 TEQ 300-7215WIR 43 – 160 VDC 24 VDC 13.5 A Short circuit protection continuous, automatic recovery TEQ 300-7216WIR 28 VDC 12 A Reverse input protection parallel diode TEQ 300-7218WIR 48 VDC 7 A Efficiency 89 % typ. Operating temperature –40 °C to +55°C without derating range up to +75°C with derating Thermal protection shutdown at 120 °C I/O isolation voltage 2250 VDC (60 sec.), basic insulation Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, EN 50155, UL508 approvals (reports pending) Thermal shock and EN 61373 / MIL-STD-810F shock & vibration Remote On/Off shutdown input for low input current (3 mA) in standby operation Full datasheet www.tracopower.com/products/teq300wir.pdf Dimensions Pin 1, 2, 3 + Vin 4, 5, 6 –Vin 7 Remote On/Off 8, 9, 10 +Vout 11, 12, 13 – Vout 14 + Sense 15 Trim 16 - Sense 142.4 (5.61) 17 Current share* * Option 152.4 (6.00) () = Inches 110 NEW Product 101.6 (4.00) 38.6 (1.52) 50.8 (2.00) 10.0 (0.39) www.tracopower.com Reinforced Insulation - Industrial / Medical Safety DC/DC Converters CB CB TMV-EN Series 1 W Schem Schemee UL 60950-1 SIP package Reinforced insulation rated for 300 VAC working voltage IEC/UL 60950-1 safety approvals I/O isolation voltage 3000 VACrms Operating temperature range –40 °C to +85 °C Over voltage category OCV III Specifications Models Order code Input voltage Output voltage Output current Line regulation non regulated max. Load regulation ±10 % max. TMV 0505EN 5 VDC 200 mA Ripple & noise <120 mVpk-pk (20 MHz BW) TMV 0512EN 12 VDC 80 mA Short circuit protection limited 1 sec. TMV 0515EN 5 VDC ± 10 % 15 VDC 65 mA Efficiency 67 % typ. TMV 0505DEN ± 5 VDC ± 100 mA TMV 0512DEN ± 12 VDC ± 40 mA Operating temperature –40 °C to +85 °C range above 70 °C derating 3.3 %/K TMV 0515DEN ± 15 VDC ± 30 mA I/O isolation voltage 3000 VACrms (60 sec.), reinforced insulation, rated for TMV 1205EN 5 VDC 200 mA 300 VAC working voltage TMV 1212EN 12 VDC 80 mA TMV 1215EN 12 VDC ± 10 % 15 VDC 65 mA I/O isolation test voltage 4500 Vpk (1 sec.) TMV 1205DEN ± 5 VDC ± 100 mA I/O isolation capacitance 15 pF typ. TMV 1212DEN ± 12 VDC ± 40 mA I/O isolation resistance >10 GOhm TMV 1215DEN ± 15 VDC ± 30 mA Safety standards / UL 60950-1, IEC/EN 60950-1, CB-report approvals Casing plastic (UL 94 V-0 rated) Full datasheet www.tracopower.com/products/tmv-en.pdf Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 2 – Vin (GND) – Vin (GND) 5 – Vout – Vout 6 No pin Common 7 + Vout + Vout 0.5 (0.02) 3.5 2.54 7.62 2.542.54 (0.14) (0.1) (0.3) (0.1) (0.1) 22.0 (0.87) Bottom view 1 2 5 6 7 0.5 (0.02) () = Inches 111 0.25 (0.01) 1.75 (0.07) 3.2 0.5 (0.02) (0.13) 12.5 (0.49) 7.5 (0.30) www.tracopower.com DC/DC Converters Reinforced Insulation - Industrial / Medical Safety CB CB Schem Schemee TES-2M Series 2 W IEC 60950-1 UL 60950-1 UL 60950-1 IEC 60601-1 ES 60601-1 Ultracompact SMD package I/O isolation 4000 VACrms Reinforced insulation rated for working voltage up to 300 VAC Industrial and medical safety approval Operating temperature range –40 °C to +71 °C Low leakage current <2µA Optional tape & reel package Specifications Models Order code Input voltage Output voltage Output current Line regulation non regulated max. Load regulation 10 % max. TES 2-0511M 5 VDC 400 mA Ripple & noise <150 mVpk-pk (20 MHz BW) TES 2-0512M 12 VDC 165 mA Input filter Pi-filter TES 2-0513M 5 VDC ± 10 % 15 VDC 133 mA Short circuit protection limited 0.5 sec. TES 2-0522M ± 12 VDC ± 83 mA TES 2-0523M ± 15 VDC ± 66 mA Efficiency 70 % typ. TES 2-1211M 5 VDC 400 mA Operating temperature –25 °C to +71 °C range above 60 °C derating 2.5 %/K TES 2-1212M 12 VDC 165 mA TES 2-1213M 12 VDC ± 10 % 15 VDC 133 mA I/O isolation voltage 4000 VACrms (reinforced), rated for 300 VAC working TES 2-1222M ± 12 VDC ± 83 mA voltage TES 2-1223M ± 15 VDC ± 66 mA I/O isolation test voltage 6000 Vpk (1 sec.) TES 2-2411M 5 VDC 400 mA I/O isolation capacitance 20 pF typ. TES 2-2412M 12 VDC 165 mA I/O isolation resistance >10,000 MOhm TES 2-2413M 24 VDC ± 10 % 15 VDC 133 mA Leakage current 2µA max. (at 240VAC / 60Hz) TES 2-2422M ± 12 VDC ± 83 mA Safety standards / UL 60950-1, IEC/EN 60950-1, ES 60601-1, IEC/EN 60601-1, CB- TES 2-2423M ± 15 VDC ± 66 mA approvals report Casing plastic, insert mold (UL 94-0 rated) Full datasheet www.tracopower.com/products/tes2m.pdf Product with same electrical specifications available in DIP package. See THI-2M series page 113 Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 7 No con. No con. 8 No con. Common 9 + Vout + Vout 10 – Vout – Vout 16 + Vin (Vcc) + Vin (Vcc) 0.25 13.7 (0.54) (0.01) 9.0 (0.35) 18.1 (0.71) () = Inches 112 24.0 (0.94) 1.0 (0.04) 16 10 9 top view 17 8 3.11 15.24 (0.60) 2.54 (0.12) (0.10) www.tracopower.com Reinforced Insulation - Industrial / Medical Safety DC/DC Converters CB CB Schem Schemee UL 60950-1 THI-2M Series 2 W IEC 60950-1 UL 60950-1 UL 60601-1 IEC 60601-1 ES 60601-1 Ultra compact DIP 16 package I/O isolation 4000 VACrms Reinforced insulation rated for working voltage up to 300 VAC Industrial and medical safety approval Operating temperature range –40 °C to +71 °C Low leakage current <2µA Specifications Models Order code Input voltage Output voltage Output current Line regulation non regulated max. Load regulation 10 % max. THI 2-0511M 5 VDC 400 mA Ripple & noise <150 mVpk-pk (20 MHz BW) THI 2-0512M 12 VDC 165 mA Input filter Pi-filter THI 2-0513M 5 VDC ± 10 % 15 VDC 133 mA Short circuit protection limited 0.5 sec. THI 2-0522M ± 12 VDC ± 83 mA THI 2-0523M ± 15 VDC ± 66 mA Efficiency 70 % typ. THI 2-1211M 5 VDC 400 mA Operating temperature –40 °C to +71 °C range above 60 °C derating 2.5 %/K THI 2-1212M 12 VDC 165 mA THI 2-1213M 12 VDC ± 10 % 15 VDC 133 mA I/O isolation voltage 4000 VACrms (60 sec.), reinforced insulation, rated for THI 2-1222M ± 12 VDC ± 83 mA 300 VAC working voltage THI 2-1223M ± 15 VDC ± 66 mA I/O isolation test voltage 6000 Vpk (1 sec.) THI 2-2411M 5 VDC 400 mA I/O isolation capacitance 20 pF typ. THI 2-2412M 12 VDC 165 mA I/O isolation resistance >10,000 MOhm THI 2-2413M 24 VDC ± 10 % 15 VDC 133 mA Leakage current 2µA max. (at 240VAC / 60Hz) THI 2-2422M ± 12 VDC ± 83 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, ES 60601-1, THI 2-2423M ± 15 VDC ± 66 mA approvals IEC/EN 60601-1, CB-report Casing plastic (UL 94V-O rated) Full datasheet www.tracopower.com/products/thi2m.pdf Product with same electrical specifications available in SMD package. See TES-2M series page 112 Dimensions Pin Single output Dual output 1 – Vin (GND) – Vin (GND) 7 No con. No con. 16 1 8 No con. Common 9 + Vout + Vout bottom 10 – Vout – Vout view 16 + Vin (Vcc) + Vin (Vcc) 10 7 9 8 0.5 (0.02) 1.77 10.16 (0.07) 3.2 8.6 (0.34) 13.7 (0.54) (0.13) () = Inches 113 3.0 (0.12) 2.54 15.24 (0.60) (0.10) 23.8 (0.94) www.tracopower.com DC/DC Converters Reinforced Insulation - Industrial / Medical Safety CB CB Schem Schemee THI-3 Series 3 W IEC 60950-1 ES 60601-1 UL 60950-1 IEC 60601-1 Supplementary and reinforced insulation I/O isolation 4000 VACrms rated for 300 VACrms working voltage 2 x MOOP medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition Industrial safety to IEC/EN 60950-1 Operating temperature range –40 °C to +75 °C Low leakage current <2µA Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5% max. Load regulation 1% max. THI 3-0511 5 VDC 600 mA Ripple & noise <50 mVpk-pk (20 MHz BW) THI 3-0512 12 VDC 250 mA Input filter Pi-filter THI 3-0513 5 VDC ± 10 % 15 VDC 200 mA Short circuit protection limited 0.5 sec. THI 3-0522 ± 12 VDC ± 125 mA THI 3-0523 ± 15 VDC ± 100 mA Efficiency 60 % typ. THI 3-1211 5 VDC 600 mA Operating temperature –40 °C to +75 °C range above 60 °C derating 2.8 %/K THI 3-1212 12 VDC 250 mA THI 3-1213 12 VDC ± 10 % 15 VDC 200 mA I/O isolation voltage 4000 VACrms (reinforced), rated for 300 VAC working THI 3-1222 ± 12 VDC ± 125 mA voltage THI 3-1223 ± 15 VDC ± 100 mA I/O isolation test voltage 6000 Vpk (1 sec.) THI 3-2411 5 VDC 600 mA I/O isolation capacitance 20 pF typ. THI 3-2412 12 VDC 250 mA I/O isolation resistance >10,000 MOhm THI 3-2413 24 VDC ± 10 % 15 VDC 200 mA Leakage current 2µA max. (at 240VAC / 60Hz) THI 3-2422 ± 12 VDC ± 125 mA Safety standards / IEC/EN 60950-1, IEC/EN 60601-1 3rd Edition, THI 3-2423 ± 15 VDC ± 100 mA approvals ANSI/AAMI ES60601-1 and CAN/CSA-C22.2 No. 60601-1, CB report Casing plastic (UL 94-0 rated plastic) Full datasheet www.tracopower.com/products/thi3.pdf Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 2 + Vin (Vcc) + Vin (Vcc) 10 No pin Common 24 1 11 No pin Common 2 23 12 – Vout No pin 13 + Vout – Vout 15 No pin + Vout 23 – Vin (GND) – Vin (GND) 15 10 24 – Vin (GND) – Vin (GND) 11 13 12 2.54 15.22 (0.6) (0.1) 3.8 10.5 20.3 (0.15) (0.41) (0.8) () = Inches 114 NEW Product 31.8 (1.25) 27.94 2.0 (1.1) (0.08) 2.54 20.32 2.54 2.54 (0.1) (0.1) (0.8) (0.1) bottom view www.tracopower.com Reinforced Insulation - Industrial / Medical Safety DC/DC Converters CB CB Schem Schemee UL 60950-1 THB-3 Series 3 W IEC 60950-1 ES 60601-1 UL 60950-1 UL 60950-1 UL 60601-1 IEC 60601-1 Wide 2:1 input voltage range I/O isolation voltage 4800 VACrms Reinforced insulation rated for working voltage 1000 VAC Medical safety to UL 60601-1 and IEC/EN 60601-1 3rd edition, 2 x MOOP Industrial safety to IEC/EN/UL 60950-1 Low coupling capacitance (13pF) Input filter to meet EN 55022, class A Low leakage current <2µA Specifications Models Order code Input voltage Output voltage Output current Line regulation ±0.5 % max. max. Load regulation – Single output models: 1 % max. THB 3-0511 5 VDC 600 mA – Dual output models: 2 % max. THB 3-0512 12 VDC 250 mA Ripple & noise <150 mVpk-pk (20 MHz BW) THB 3-0515 4.5 – 9 VDC 24 VDC 125 mA Conducted EMI EN 55022, class A (internal filter) THB 3-0522 ± 12 VDC ± 125 mA Short circuit protection continuous, automatic recovery THB 3-0523 ± 15 VDC ± 100 mA Efficiency 83 % typ. THB 3-1211 5 VDC 600 mA Operating temperature –40 °C to +75 °C THB 3-1212 12 VDC 250 mA range above 60 °C derating 3.3 %/K THB 3-1215 9 – 18 VDC 24 VDC 125 mA THB 3-1222 ± 12 VDC ± 125 mA I/O isolation voltage 4800 VACrms (60 sec.) reinforced insulation, rated for 1000 VAC working voltage THB 3-1223 ± 15 VDC ± 100 mA I/O isolation test voltage 6000 Vpk (1sec) THB 3-2411 5 VDC 600 mA THB 3-2412 12 VDC 250 mA I/O isolation capacitance 13 pF max. THB 3-2415 18 – 36 VDC 24 VDC 125 mA Leakage current 2µA max. (at 240VAC / 60Hz) THB 3-2422 ± 12 VDC ± 125 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, ES 60601-1, THB 3-2423 ± 15 VDC ± 100 mA approvals IEC/EN 60601-1, CB-report THB 3-4811 5 VDC 600 mA Casing plastic (UL 94V-O rated) THB 3-4812 12 VDC 250 mA Full datasheet www.tracopower.com/products/thb3.pdf THB 3-4815 36 – 75 VDC 24 VDC 125 mA THB 3-4822 ± 12 VDC ± 125 mA THB 3-4823 ± 15 VDC ± 100 mA Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 11 No pin Common 24 1 23 12 – Vout No pin 13 + Vout – Vout 15 No pin + Vout 23 – Vin (GND) – Vin (GND) 24 – Vin (GND) – Vin (GND) 15 11 13 12 2.54 15.24 (0.6) (0.1) 3.9 10.7 20.3 (0.15) (0.42) (0.8) () = Inches 115 31.8 (1.25) 27.94 1.9 (1.1) (0.07) 2.54 2.54 20.32 2.54 (0.1) (0.1) (0.8) (0.1) Bottom view www.tracopower.com DC/DC Converters Reinforced Insulation - Industrial / Medical Safety CB CB THP-3 Series 3 W UL 60950-1 Schem Schemee UL 60601-1 Ultra wide 4:1 input voltage range up to 160VDC I/O isolation voltage 4000 VACrms Reinforced insulation rated for working voltage 300 VAC Industrial and medical safety approvals Operating temperature range –40 °C to +85 °C Low coupling capacitance (13pF) Input filter to meet EN 55022, class A Low leakage current <2µA Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation – Single output models: 1 % max. THP 3-2411 5 VDC 600 mA – Dual output models: 2 % max. THP 3-2412 9 – 40 VDC 12 VDC 250 mA Ripple & noise <100 mVpk-pk for 5 VDC models THP 3-2422 ± 12 VDC ± 125 mA (20 MHz BW) <150 mVpk-pk for other models THP 3-2423 ± 15 VDC ± 100mA Conducted EMI EN 55022, class A (internal filter) THP 3-4811 5 VDC 600 mA Short circuit protection continuous, automatic recovery THP 3-4812 18 – 80 VDC 12 VDC 250 mA Efficiency 83 % typ. THP 3-4822 ± 12 VDC ± 125 mA Operating temperature –40 °C to +85 °C THP 3-4823 ± 15 VDC ± 100mA range above 70 °C derating 3.3 %/K THP 3-7211 5 VDC 600 mA I/O isolation voltage 4000 VACrms (60 sec.) reinforced insulation, rated for THP 3-7212 36 – 160 VDC 12 VDC 250 mA 300 VAC working voltage THP 3-7222 ± 12 VDC ± 125 mA I/O isolation test voltage 6000 Vpk (1sec) THP 3-7223 ± 15 VDC ± 100mA I/O isolation capacitance 13 pF max. Leakage current 2µA max. (at 240VAC / 60Hz) Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, ES 60601-1, IEC/EN 60601-1, approvals CB-report Casing plastic (UL 94V-O rated) Full datasheet www.tracopower.com/products/thp3.pdf Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 11 No pin Common 24 1 23 12 – Vout No pin 13 + Vout – Vout 15 No pin + Vout 23 – Vin (GND) – Vin (GND) 24 – Vin (GND) – Vin (GND) 15 11 13 12 2.54 15.24 (0.6) (0.1) 3.9 10.7 20.3 (0.15) (0.42) (0.8) () = Inches 116 31.8 (1.25) 27.94 1.9 (1.1) (0.07) 2.54 2.54 20.32 2.54 (0.1) (0.8) (0.1) (0.1) Bottom view www.tracopower.com Reinforced Insulation - Industrial / Medical Safety DC/DC Converters CB CB THM-3WI Series 3 W UL ES 60601-1 60950-1 Schem Schemee UL 60950-1 Ultra wide 4:1 input voltage range I/O isolation 5000 VACrms rated for 250 VACrms working voltage 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition Extended operating temperature range –40 °C to +94 °C at full load ! Low leakage current < 2µA Input filter to meet EN 55022, class A Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation – Single output models: 0.2 % max. THM 3-0510WI 3.3 VDC 1000 mA – Dual output models: 1 % max. THM 3-0511WI 5 VDC 600 mA Ripple & noise 3.3 & 5 VDC models: 30 mVpk-pk typ. (20MHz BW) THM 3-0512WI 12 VDC 250 mA 12 & 15 VDC models: 40 mVpk-pk typ. (20MHz BW) THM 3-0513WI 4.5 - 9 VDC 15 VDC 200 mA 24 VDC models: 50 mVpk-pk typ. (20MHz BW) THM 3-0515WI 24 VDC 125 mA Conducted EMI EN 55022, class A (internal filter) THM 3-0521WI ± 5 VDC ± 300 mA Short circuit protection continuous, automatic recovery THM 3-0522WI ± 12 VDC ± 125 mA Efficiency 83 % typ. THM 3-0523WI ± 15 VDC ± 100 mA Operating temperature –40 °C to +94 °C without derating THM 3-2410WI 3.3 VDC 1000 mA range THM 3-2411WI 5 VDC 600 mA I/O isolation voltage 5000 VACrms (60 sec.) reinforced insulation, rated for THM 3-2412WI 12 VDC 250 mA 250 VAC working voltage THM 3-2413WI 9 - 36 VDC 15 VDC 200 mA I/O isolation test voltage 6000 Vpk (1sec) THM 3-2415WI 24 VDC 125 mA I/O isolation capacitance 17 pF max. THM 3-2421WI ± 5 VDC ± 300 mA Safety standards / ANSI/AAMI ES 60601-1:2005/(R)2012, THM 3-2422WI ± 12 VDC ± 125 mA approvals IEC/EN 60601-1 3rd edition, CB-report THM 3-2423WI ± 15 VDC ± 100 mA Casing plastic (UL 94V-O rated) THM 3-4810WI 3.3 VDC 1000 mA THM 3-4811WI 5 VDC 600 mA Full datasheet www.tracopower.com/products/thm3wi.pdf THM 3-4812WI 12 VDC 250 mA THM 3-4813WI 18 - 75 VDC 15 VDC 200 mA THM 3-4815WI 24 VDC 125 mA THM 3-4821WI ± 5 VDC ± 300 mA THM 3-4822WI ± 12 VDC ± 125 mA THM 3-4823WI ± 15 VDC ± 100 mA Dimensions Standard pinning Optional pinning: suffix -A1 Pin Single output Dual output 2 – Vin (GND) – Vin (GND) 1 11 12 11 No con. – Vout 2 11 14 + Vout + Vout Bottom view Bottom view 16 – Vout Common 24 23 15 13 22 + Vin (Vcc) + Vin (Vcc) 23 22 16 14 23 + Vin (Vcc) + Vin (Vcc) 31.8 (1.25) 31.8 (1.25) 2.0 (0.08) 4.5 (0.18) 2.54 20.32 (0.80) 2x2.54 (0.10) (2x0.1) 2.54 15.24 (0.60) 5.08 (0.10) (0.20) () = Inches 117 NEW Product 3.8 (0.40) 2.54 15.24 (0.60) 10.2 (0.15) (0.10) 20.3 (0.80) 3.8 (0.40) 2.54 15.24 (0.60) 10.2 (0.15) (0.10) (0.80) 20.3 www.tracopower.com DC/DC Converters Reinforced Insulation - Industrial / Medical Safety CB CB Schem Schemee THB-6 Series 6 W UL 60950-1 IEC 60950-1 ES 60601-1 UL 60950-1 UL 60950-1 IEC 60601-1 UL 60601-1 Wide 2:1 input voltage range I/O isolation voltage 4800 VACrms Reinforced insulation rated for working voltage 1000 VAC Medical safety to UL 60601-1 and IEC/EN 60601-1 3rd edition, 2 x MOOP Operating temperature range –40 °C to +71 °C Industrial safety to IEC/EN/UL 60950-1 Low coupling capacitance (13pF) Input filter to meet EN 55022, class A Low leakage current <2µA Specifications Models Order code Input voltage Output voltage Output current Line regulation 1.0 % max. max. Load regulation – Single output models: 1 % max. THB 6-1211 5 VDC 1000 mA – Dual output models: 2 % max. THB 6-1212 9 – 18 VDC 12 VDC 500 mA Ripple & noise <100 mVpk-pk for 5 VDC models THB 6-1222 ± 12 VDC ± 250 mA (20 MHz BW) <150 mVpk-pk for other models THB 6-1223 ± 15 VDC ± 200mA Conducted EMI EN 55022, class A (internal filter) THB 6-2411 5 VDC 1000 mA Short circuit protection continuous, automatic recovery THB 6-2412 18 – 36 VDC 12 VDC 500 mA Efficiency 80 % typ. THB 6-2422 ± 12 VDC ± 250 mA Operating temperature –40 °C to +71 °C THB 6-2423 ± 15 VDC ± 200mA range above 60 °C derating 3 %/K THB 6-4811 5 VDC 1000 mA I/O isolation voltage 4000 VACrms (60 sec.) reinforced insulation, rated for THB 6-4812 36 – 75 VDC 12 VDC 500 mA 300 VAC working voltage THB 6-4822 ± 12 VDC ± 250 mA I/O isolation test voltage 6000 Vpk (1sec) THB 6-4823 ± 15 VDC ± 200mA I/O isolation capacitance 13 pF max. Leakage current 2µA max. (at 240VAC / 60Hz) Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, ES 60601-1, approvals IEC/EN 60601-1, CB-report Casing plastic (UL 94V-O rated) Full datasheet www.tracopower.com/products/thb6.pdf Dimensions Pin Single output Dual output 1 + Vin (Vcc) + Vin (Vcc) 11 No pin Common 12 – Vout No pin 24 1 23 13 + Vout – Vout 15 No pin + Vout 23 – Vin (GND) – Vin (GND) 24 – Vin (GND) – Vin (GND) 15 11 13 12 2.54 15.24 (0.6) (0.1) 3.9 12.0 20.3 (0.15) (0.42) (0.8) () = Inches 118 31.8 (1.25) 27.94 1.9 (1.1) (0.07) 2.54 2.54 20.32 2.54 (0.1) (0.8) (0.1) (0.1) Bottom view www.tracopower.com Reinforced Insulation - Industrial / Medical Safety DC/DC Converters CB CB THM-6WI Series 6 W ES 60601-1 UL 60950-1 Schem Schemee UL 60950-1 Ultra wide 4:1 input voltage range I/O isolation 5000 VACrms rated for 250 VACrms working voltage 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition Extended operating temperature range –40 °C to +88 °C at full load ! Low leakage current < 2µA Input filter to meet EN 55022, class A Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation – Single output models: 0.2 % max. THM 6-0510WI 3.3 VDC 1800 mA – Dual output models: 1 % max. THM 6-0511WI 5 VDC 1200 mA Ripple & noise 3.3 & 5 VDC models: 30 mVpk-pk typ. (20MHz BW) THM 6-0512WI 12 VDC 500 mA 12 & 15 VDC models: 40 mVpk-pk typ. (20MHz BW) THM 6-0513WI 4.5 - 9 VDC 15 VDC 400 mA 24 VDC models: 50 mVpk-pk typ. (20MHz BW) THM 6-0515WI 24 VDC 250 mA Conducted EMI EN 55022, class A (internal filter) THM 6-0521WI ± 5 VDC ± 600 mA Short circuit protection continuous, automatic recovery THM 6-0522WI ± 12 VDC ± 250 mA Efficiency 86 % typ. THM 6-0523WI ± 15 VDC ± 200 mA Operating temperature –40 °C to +88 °C without derating THM 6-2410WI 3.3 VDC 1800 mA range THM 6-2411WI 5 VDC 1200 mA I/O isolation voltage 5000 VACrms (60 sec.) reinforced insulation, rated for THM 6-2412WI 12 VDC 500 mA 250 VAC working voltage THM 6-2413WI 9 - 36 VDC 15 VDC 400 mA I/O isolation test voltage 6000 Vpk (1sec) THM 6-2415WI 24 VDC 250 mA I/O isolation capacitance 17 pF max. THM 6-2421WI ± 5 VDC ± 600 mA Leakage current 2µA max. (at 240VAC / 60Hz) THM 6-2422WI ± 12 VDC ± 250 mA THM 6-2423WI ± 15 VDC ± 200 mA Safety standards / ANSI/AAMI ES 60601-1:2005/(R)2012, approvals IEC/EN 60601-1 3rd edition, CB-report THM 6-4810WI 3.3 VDC 1800 mA THM 6-4811WI 5 VDC 1200 mA Casing plastic (UL 94V-O rated) THM 6-4812WI 12 VDC 500 mA Full datasheet www.tracopower.com/products/thm6wi.pdf THM 6-4813WI 18 - 75 VDC 15 VDC 400 mA THM 6-4815WI 24 VDC 250 mA THM 6-4821WI ± 5 VDC ± 600 mA THM 6-4822WI ± 12 VDC ± 250 mA THM 6-4823WI ± 15 VDC ± 200 mA Dimensions Standard pinning Optional pinning: suffix -A1 Pin Single output Dual output 2 – Vin (GND) – Vin (GND) 1 11 12 11 No con. – Vout 2 11 14 + Vout + Vout Bottom view Bottom view 16 – Vout Common 24 23 15 13 22 + Vin (Vcc) + Vin (Vcc) 23 22 16 14 23 + Vin (Vcc) + Vin (Vcc) 31.8 (1.25) 31.8 (1.25) 2.0 (0.08) 4.5 (0.18) 2.54 20.32 (0.80) 2x2.54 (0.10) (2x0.1) 2.54 15.24 (0.60) 5.08 (0.10) (0.20) () = Inches 119 NEW Product 3.8 (0.40) 2.54 15.24 (0.60) 10.2 (0.15) (0.10) 20.3 (0.80) 3.8 (0.40) 2.54 15.24 (0.60) 10.2 (0.15) (0.10) (0.80) 20.3 www.tracopower.com DC/DC Converters Reinforced Insulation - Industrial / Medical Safety CB CB Schem Schemee THB-10 Series 10 W IEC 60950-1 UL 60950-1 UL 60950-1 IEC 60601-1 ES 60601-1 Wide 2:1 input voltage range I/O isolation voltage 4000 VACrms Reinforced insulation rated for working voltage 300 VAC Industrial and medical safety approvals Operating temperature range –40 °C to +75 °C Input filter to meet EN 55022, class A Low leakage current Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation 1 % max. THB 10-1211 5.1 VDC 1600 mA Ripple & noise <100 mVpk-pk for 5 VDC models THB 10-1212 9 – 18 VDC 12 VDC 835 mA (20 MHz BW) <150 mVpk-pk for other models THB 10-1222 ± 12 VDC ± 417 mA Conducted EMI EN 55022, class A (internal filter) THB 10-1223 ± 15 VDC ± 333mA Short circuit protection continuous, automatic recovery THB 10-2411 5.1 VDC 1600 mA Efficiency 80 % typ. THB 10-2412 18 – 36 VDC 12 VDC 835 mA THB 10-2422 ± 12 VDC ± 417 mA Operating temperature –40 °C to +75 °C range above 55 °C derating 2.5 %/K THB 10-2423 ± 15 VDC ± 333mA THB 10-4811 5.1 VDC 1600 mA I/O isolation voltage 4000 VACrms (60 sec.) reinforced, rated for 300 VAC working voltage THB 10-4812 36 – 75 VDC 12 VDC 835 mA I/O isolation test voltage 6000 Vpk (1sec) THB 10-4822 ± 12 VDC ± 417 mA THB 10-4823 ± 15 VDC ± 333mA I/O isolation capacitance 60 pF typ. Leakage current 10µA max. (at 240VAC / 60Hz) Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, UL 60601-1, IEC/EN 60601-1, approvals (reports pending) Casing plastic (UL 94V-O rated) Full datasheet www.tracopower.com/products/thb10.pdf Dimensions Pin Single output Dual output 5.08 (0.2) 2.54 1 + Vin (Vcc) + Vin (Vcc) (0.1) 2 – Vin (GND) – Vin (GND) 3 + Vout + Vout 2 1 4 No pin Common 5 – Vout – Vout Bottom V iiew 5 4 3 5.08 10.16 (0.2) (0.4) 12.0 20.32 (0.47) (0.8) 25.4 (1.0) () = Inches 120 45.72(1.8) 2.5 (0.1) 50.8 (2.0) www.tracopower.com Reinforced Insulation - Industrial / Medical Safety DC/DC Converters CB CB THM-10WI Series 10 W UL ES 60601-1 60950-1 Schem Schemee UL 60950-1 Ultra wide 4:1 input voltage range I/O isolation 5000 VACrms rated for 250 VACrms working voltage 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition Extended operating temperature range –40 °C to +77 °C at full load ! Low leakage current < 2µA Input filter to meet EN 55022, class A Specifications Models Order code Input voltage Output voltage Output current Line regulation 0.5 % max. max. Load regulation – Single output models: 0.2 % max. THM 10-0510WI 3.3 VDC 2500 mA – Dual output models: 1 % max. THM 10-0511WI 5 VDC 2000 mA Ripple & noise 3.3 & 5 VDC models: 30 mVpk-pk typ. (20MHz BW) THM 10-0512WI 12 VDC 830 mA 12 & 15 VDC models: 40 mVpk-pk typ. (20MHz BW) THM 10-0513WI 4.5 - 9 VDC 15 VDC 670 mA 24 VDC models: 50 mVpk-pk typ. (20MHz BW) THM 10-0515WI 24 VDC 416 mA Conducted EMI EN 55022, class A (internal filter) THM 10-0521WI ± 5 VDC ± 1000 mA Short circuit protection continuous, automatic recovery THM 10-0522WI ± 12 VDC ± 416 mA Efficiency 87 % typ. THM 10-0523WI ± 15 VDC ± 333 mA Operating temperature –40 °C to +77 °C without derating THM 10-2410WI 3.3 VDC 2500 mA range above 77°C derating 3.6%/K THM 10-2411WI 5 VDC 2000 mA I/O isolation voltage 5000 VACrms (60 sec.) reinforced insulation, rated for THM 10-2412WI 12 VDC 830 mA 250 VAC working voltage THM 10-2413WI 9 - 36 VDC 15 VDC 670 mA I/O isolation test voltage 6000 Vpk (1sec) THM 10-2415WI 24 VDC 416 mA I/O isolation capacitance 17 pF max. THM 10-2421WI ± 5 VDC ± 1000 mA Leakage current 2µA max. (at 240VAC / 60Hz) THM 10-2422WI ± 12 VDC ± 416 mA THM 10-2423WI ± 15 VDC ± 333 mA Safety standards / ANSI/AAMI ES 60601-1:2005/(R)2012, approvals IEC/EN 60601-1 3rd edition, CB-report THM 10-4810WI 3.3 VDC 2500 mA THM 10-4811WI 5 VDC 2000 mA Casing plastic (UL 94V-O rated) THM 10-4812WI 12 VDC 830 mA Full datasheet www.tracopower.com/products/thm10wi.pdf THM 10-4813WI 18 - 75 VDC 15 VDC 670 mA THM 10-4815WI 24 VDC 416 mA THM 10-4821WI ± 5 VDC ± 1000 mA THM 10-4822WI ± 12 VDC ± 416 mA THM 10-4823WI ± 15 VDC ± 333 mA Dimensions Standard pinning Optional pinning: suffix -A1 Pin Single output Dual output 2 – Vin (GND) – Vin (GND) 2 11 1 11 12 11 No con. – Vout 14 + Vout + Vout Bottom view Bottom view 16 – Vout Common 24 23 15 13 22 + Vin (Vcc) + Vin (Vcc) 23 22 16 14 23 + Vin (Vcc) + Vin (Vcc) 31.8 (1.25) 31.8 (1.25) 2.0 (0.08) 4.5 (0.18) 2.54 20.32 (0.80) 2x2.54 (0.10) (2x0.1) 2.54 15.24 (0.60) 5.08 (0.10) (0.20) () = Inches 121 NEW Product 3.8 (0.40) 2.54 15.24 (0.60) 10.2 (0.15) (0.10) 20.3 (0.80) 3.8 (0.40) 2.54 15.24 (0.60) 10.2 (0.15) (0.10) (0.80) 20.3 www.tracopower.com DC/DC Converters High Voltage Converters THV / PHV Series 2/5 W Ultra compact high voltage converter up to 2000 VDC Full SMD-design with ceramic capacitors for high reliability Very low electromagnetic interferance Excellent output stability Low temperature drift Remote voltage programming Short circuit protection Positive or negative output models PCB-mount or flying lead version Shielded metal casing Specifications Specifications THV Models 2 Watt Models Order code * Input voltage Output voltage Output current Case range max. Line regulation 0.03 % for THV THV 12-180P 0 – 180 VDC 15 mA A 0.01 % for PHV THV 12-300P 0 – 300 VDC 10 mA A 10.8 – 13.2 VDC Load regulation THV models: 0.08 % THV 12-350P 0 – 350 VDC 7 mA A PHV models: 0.1 % THV 12-500P 0 – 500 VDC 6 mA B Output voltage 0…100 % (by external resistor or reference voltage) THV 12-1000P 0 – 1000 VDC 2 mA B adjustment THV 12-1500P 0 – 1500 VDC 1.3 mA B 10.8 – 16.5 VDC Ripple & noise THV: < 30 mVpk-pk (20 MHz BW) THV 12-2000P 0 – 2000 VDC 1 mA B PHV: <100 mVpk-pk (20 MHz BW) * replace suffix P by suffix N for negative output Short circuit protection continuous Efficiency 65 % typ. Operating temperature THV models: –10 ° C to +60 ° C, above 50 ° C derating 4 %/K PHV Models 5 Watt range PHV models: –10 ° C to +50 ° C, above 40 ° C derating 4 %/K Order code * Input voltage Output voltage Output current Case range max. Temperature coefficient 0.01 %/K PHV 12-350 S 10P 0 – 350 VDC 10 mA C Stability 0.05 %/8 h drift PHV 12-0.5 K 1000P 0 – 500 VDC 10 mA C 10.8 – 16.5 VDC Remote On/Off for THV 500–2,000 VDC and PHV models PHV 12-1.0 K 5000P 0 – 1000 VDC 5 mA C Casing metal PHV 12-2.0 K 2500P 0 – 2000 VDC 2.5 mA C Full datasheet www.tracopower.com/products/thv.pdf * replace suffix P by suffix N for negative output www.tracopower.com/products/phv.pdf Dimensions Pin Case A Case B Case C 1 + Vin (Vcc) + Vin (VCC) + Vin (Vcc) 2 – Vin (GND) – Vin (GND) – Vin (GND) Case A / B 3 Vadj. Vadj. Vadj. 1 – 5 6 7 4 Vref. Vref. Vref. 5 No pin Remote On/Off Remote On/Off Case A : 80 / C ase B: 110 12 (3.15) (4.33) (0.47) 6 – Vout – Vout – Vout 7 + Vout + Vout + Vout Models with flying lead Case C 5.08 5.08 5.08 5.08 12.38 connection available on (0 .2 )(0.2) (0 .2 )(0.2) (0.49) request 5 4 3 2 1 Bo ttom v ie w 6 7 11 t yp 15 3.5 W M odels 9.84 20.32 (0.6) (0.39) (0.8) (0.49 t yp ) 20 5.0 W M odels 40 (1.57) (0.8) () = Inches 122 60 (2.36) 9.68 40.64 (1.6) (0.38) 19.8 (0.78) www.tracopower.com Industrial Converters, DIN-Rail Mount DC/DC Converters CB TCL-DC Series 24 to 60 W Scheme UL 60950-1 UL 508 Slim plastic case For industrial-, office- and residential environments Available with detachable screw terminals or spring clamps Standard models with 5, 12 and 24 VDC output Models with: 9.5-18 VDC and 18-75 VDC output Worldwide safety approval package Adjustable output voltage Power Good signal Parallel and redundant operation Specifications Models Order code Output power Output voltage Output current Output regulation 1.25 % max. max. (adjustable output) max. Ripple & noise <50 mVpk-pk (20 MHz BW) TCL 012-124DC 9.5 – 18 VDC 24 VDC 1.0 A EMI emission EN 55011, class B, EN 55022, class B, EN61000-6-3 TCL 024-105DC 5 VDC 5.0 A EMC immunity EN 61000-6-2 (industrial environment) TCL 024-112DC 12 VDC 2.0 A 18 – 75 VDC Output current limitation at 130 % of Iout max. TCL 024-124DC 24 VDC 1.0 A TCL 060-112DC 12 VDC 5.0 A Over voltage protection at 140 % of Vout nom. 18 – 75 VDC TCL 060-124DC 24 VDC 2.5 A Efficiency 90 % typ. without suffix: detachable screw terminal block DC-OK Signal open collector / max. 30 mA with suffix C: spring clamps Operating temperature –25 ° C to +70 ° C above 50 ° C derating 1.5 %/K Redundancy Module Safety standards / cUL/UL 60950-1, UL 508C listed, IEC/EN 60950-1, CB-Report 2 Inputs Output voltage approvals EN 50178, EN 60204 Order code Output current max. Connection detachable screw terminals or spring clamp terminals TCL-REM240 5 – 60 VDC Vin - 0.9 VDC 8.0 A Casing plastic (UL 94V-0 rated) 144 W max./input Mounting snap-on mounting on 35 mm DIN-rail or chassis mounting with mounting bracket (included) Options output current characteristics set for battery charging applications Full datasheet www.tracopower.com/products/tcl-dc.pdf Dimensions Dimensions Type Width w Heigth h Depth d TCL 012 27 (1.06) 75 (2.95) 100 (3.94) TCL 024 & REM 27 (1.06) 75 (2.95) 100 (3.94) TCL 060 45 (1.77) 75 (2.95) 100 (3.94) d w () = Inches 123 h www.tracopower.com DC/DC Converters Industrial Converters, High Power TZL Series 60 to 300 W Compact metal casing with screw terminal block Wide 2:1 input voltage range I/O isolation 1500 VDC Input reverse polarity protection Soft start, low inrush current Overload and short circuit protection Adjustable output voltage Cost optimized design Specifications Models Order code Input voltage Output voltage Output current Line regulation 1.0 % max. range max. Load regulation 1.0 % max. TZL 060-2412 18 – 36 VDC 12 VDC 5.0 A Output voltage ±10 % (by internal potentiometer) TZL 060-2424 24 VDC 2.5 A adjustment TZL 060-4812 36 – 72 VDC 12 VDC 5.0 A Ripple & noise 12 VDC output models: <100 mVpk-pk (20 MHz BW) TZL 060-4824 24 VDC 2.5 A 24 VDC output models: <150 mVpk-pk (20 MHz BW) TZL 100-2412 19 – 36 VDC 12 VDC 8.5 A Conducted EMI EN 55022 class EN55022 class B TZL 100-2424 24 VDC 4.2 A EMC immunity EN 61000-6-1 (light industry) TZL 100-4812 36 – 72 VDC 12 VDC 8.5 A Short circuit protection foldback, automatic recovery TZL 100-4824 24 VDC 4.2 A TZL 150-2412 19 – 32 VDC 12 VDC 12.5 A Efficiency 80 % typ. TZL 150-2424 24 VDC 6.3 A Operating temperature -10 ° C to +60 ° C range above 50 ° C derating 2.5 %/K TZL 150-4812 36 – 72 VDC 12 VDC 12.5 A TZL 150-4824 24 VDC 6.3 A I/O isolation voltage 1500 VDC (60 sec.) TZL 300-4812 36 – 72 VDC 12 VDC 26.7 A Safety standards IEC/EN 60950-1 (no report) TZL 300-4824 24 VDC 13.4 A Casing aluminium / steel Full datasheet www.tracopower.com/products/tzl.pdf Dimensions Type Length Width Height l w h TZL 060 159 (6.26) 95 (3.74) 38 (1.50) TZL 100 198 (7.80) 95 (3.74) 38 (1.50) TZL 150 198 (7.80) 99 (3.90) 50 (1.97) TZL 300 212 (8.35) 115 (4.53) 50 (1.97) () = Inch 12 l 124 h w www.tracopower.com Industrial Converters, High Power DC/DC Converters TSC Series 150 to 5000 W Modular system for individual power solution Robust mechanical design for industrial applications Input voltages from 10 to 800 VDC Input under voltage lockout Standard models with output voltages up to 400 VDC Also AC input 115/230 VAC or 400/480 VAC 3P available EMI complies with EN 55022, class A Available with many options Specifications Models Input voltage range Output power Output voltage range Line regulation 0.1 % max. Load regulation 0.2 % max. 4.5 – 5.5 VDC Ripple & noise <1 % Vout + 30 mVpk-pk (20 MHz BW) 8 – 10 VDC 11 – 13 VDC Conducted EMI EN 55022, Class A 10 – 16 VDC 14 – 16 VDC Short circuit protection continuous, automatic recovery 18 – 36 VDC 23 – 26 VDC Models with 36 – 75 VDC Overvoltage protection 105 % of Vout (factory adjustable) 26 – 30 VDC 80 – 160 VDC 150W – 5000W 45 – 55 VDC Efficiency 85 % typ. 160 – 320 VDC available 58 – 68 VDC 320 – 640 VDC Operating temperature –20 ° C to +75 ° C 100 – 130 VDC 450 – 800 VDC range 200 – 250 VDC 380 – 400 VDC I/O isolation voltage 2100 VDC (Vin < 60 VDC) 3500 VDC (Vin > 60 VDC & VAC input models) Other input and output voltages on demand Safety standards IEC/EN 60950-1 (no report) Options (examples): Full datasheet www.tracopower.com/products/tsc.pdf Inrush current limiting Input voltage: 115/230 VAC, single phase or 4 Package styles available 200/400/480 VAC, three phase Input polarity protection Output decoupling diode for redundant / parallel operation Rack mount Active current sharing for parallel operation Remote On/Off (inhibit) Output programmable via analogue signal Monitoring of input an output voltage RS232 or IEEE488 interface Increased mechanical strength Tropical protection for model selection visit TRACOPOWER website Wall mount DIN rail mount Chassis mount For higher power modules DIN rail mount and chassis mount might not be suitable because of static reasons (weight) 125 www.tracopower.com DC/DC Converters Industrial Converters, High Power TSC 19“ Series 5 to 22 kW Modular system for individual power solution Robust mechanical design for industrial applications Input voltages from 20 to 800 VDC Standard models with output voltages up to 800 VDC Also AC input 115/230 VAC or 400/480 VAC 3P available EMI complies with EN 55022, Class A Available with many options Specifications Models Line regulation 0.1 % max. Input voltage range Output power Output voltage range Load regulation 0.2 % max. Ripple & noise 0.5 % Vmrs 4.5 – 5.5 VDC 8 – 10 VDC Conducted EMI EN 55022-A 11 – 13 VDC Noise Immunity EN 50082 14 – 16 VDC 40 – 64 VDC 23 – 26 VDC Short circuit protection continuous, automatic recovery 50 – 80 VDC Models with 26 – 30 VDC 80 – 160 VDC Overvoltage protection 105 % of Vout 5 kW – 22 kW 45 – 55 VDC 160 – 320 VDC Efficiency 90 % typ. 58 – 68 VDC available 320 – 640 VDC 100 – 130 VDC Operating temperature –10 ° C to +50 ° C 450 – 800 VDC 200 – 250 VDC range 380 – 400 VDC I/O isolation voltage 2100 VDC (Vin < 60 VDC) 570 – 600 VDC Other input and output voltages on demand 3500 VDC (Vin > 60 VDC & VAC input models) 760 – 800 VDC Safety standards IEC/EN 60950-1 Options (examples): Full datasheet www.tracopower.com/products/tsc.pdf Input voltage: 115/230 VAC, single phase or 200/400/480 VAC, three phase Input polarity protection Output decoupling diode for redundant / parallel operation Active current sharing for parallel operation Remote On/Off (inhibit) Output programmable via analogue signal Monitoring of input an output voltage RS232 or IEEE488 interface Wall mounting Increased mechanical strength Automatic/manual setting of output characteristic Temperature compensated battery charging voltage Digital Volt- and Ampere meter Tropical protection for model selection visit TRACOPOWER website Dimensions Power Width Depth Heigth [kW] [mm] [mm] [mm] 5/7.5/10 19” 600 178 (4U) 6/8/12 19” 360/460* 267/400 (6/9U) 22 19” 600 356 (8U) * depending on output current 126 www.tracopower.com Industrial Inverters DC/AC Inverters TSD Series 200 VA to 30 kVA True sine wave output (40-400 Hz) 19“ subracks or plug-in modules for 19” subrack Single phase or 3-phase output DC input 10 – 800 VDC AC input (for frequency conversion) Isolation between input and output Compact and robust design for industrial environment Low standby power consumption Specifications Models Line regulation 0.1 % to 2 % depending on model Input voltage range Output power Output voltage Load regulation 1 % typ. 10 – 16 VDC Harmonic distortion 3 % typ. 20 – 32 VDC EMC suppression EN 55022, Class A 40 – 64 VDC 50 – 80 VDC Single-phase EMC immunity according to EN 61000-6-2 Inverte 80 – 160 VDC 115/230 VAC models with Output current limitation at 105 % of lout max. 160 – 320 VDC Three-phase 200 VA – 30 kVA (steady state) 340 – 400 VDC 200/400/480 VAC 340 – 640 VDC Short circuit current electronically limited to 3x lout max. 450 – 800 VDC Other input and output voltages on demand Surge power 2 x Pnom. for 1 sec. Efficiency 75–94 % No-load input power 20 Watt typ. Single-phase Single-phase Frequency converter 115/230 VAC 115/230 VAC Operating temperature –20 ° C to +75 ° C models with Three-phase Three-phase above 55 ° C derating 2.5 %/K 600 VA – 36 kVA 200/400/480 VAC 200/400/480 VAC I/O isolation voltage 3000 VDC Safety standards IEC/EN60950-1 Options (examples): Full datasheet www.tracopower.com/products/tsd.pdf Inrush current limiting Input polarity protection Remote On/Off (inhibit) Output programmable via analog signal Monitoring of input and output voltage RS232 or IEEE488 interface Wall mounting Increased mechanical strength Tropical protection Static Switch for uninterruptible power supply Dimensions Dimensions Models with 1-phase output Power [kVA] Depth [mm] Width [mm] Height [mm] up to 0.6 160 213 up to 1.2 220 267 (6U) up to 1.6 284 up to 2.5 300 up to 10 460 19” 19” = 483 mm Models with 3-phase output Power [kVA] Depth [mm] Width [mm] Height [mm] 267 (6U) 0.6–10 460 19” up to 30 267 (3x 6U) * for low input voltages there will be less power in relation to the size ° for power ratings >3.6 kVA the transformer needs to be installed externally because of weight and size 127 www.tracopower.com AC/DC Power Supplies Open Frame Design CB CB TOP-60 Series TOP-60 Series 60 W 60 W Scheme Scheme UL 60950-1 UL 60950-1 4.0” x 2.0” footprint Supplies 60 W with convection cooling Single-, dual- and triple output models Compliance with EN 61000-3-2 Specifications Models Output power Order code Output 1 Output 2/3 max. Input voltage range 90–264 VAC, 47–63 Hz TOP 60105 55 W 5.0 VDC / 11.0 A Line regulation 1.0 % max. TOP 60112 60 W 12 VDC / 5.0 A Load regulation 2.0 % max. for single output models TOP 60115 64 W 15 VDC / 4.3 A 3.0 % max. for multi output models TOP 60124 64 W 24 VDC / 2.7 A Ripple & noise <100 mVpk-pk for 3.3 and 5 VDC models TOP 60148 64 W 48 VDC / 1.35 A (20 MHz BW) <120 mVpk-pk for other models 1) TOP 60252 55 W +5.0 VDC / 6.0 A +12 VDC / 3.0 A EMI emission EN 55011/22 class B, harmonic current EN 61000-3-2 1) TOP 60254 55 W +5.0 VDC / 6.0 A +24 VDC / 1.5 A EMC immunity EN 61000-6-1 1) TOP 60522 55 W +5.0 VDC / 6.0 A +12 VDC / 3.0 A Output current limitation >110 % of Iout max. -12 VDC / 0.5 A Efficiency 85 % typ. 1) TOP 60533 55 W +5.0 VDC / 6.0 A +15 VDC / 2.4 A Overvoltage protection >110 % of Vout nom. –15 VDC / 0.5 A 1) Operating temperature –10 ° C to +70 ° C (convection cooling) TOP 60316 38 W +3.3 VDC / 6.0 A +5.2 VDC / 3.0 A derating 2.0 %/K above 50 ° C, +12 VDC / 0.5 A 1) Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 CB-report TOP 60317 38 W +5.0 VDC / 6.0 A +3.3 VDC / 1.5 A approvals +12 VDC / 0.5 A 1) Degree of protection class I TOP 60318 55 W +5.0 VDC / 6.0 A +24 VDC / 1.5 A –12 VDC / 0.5 A Full datasheet www.tracopower.com/products/top60.pdf 1) 8.0 A peak current for max. 10 sec. or with forced air cooling Total power of multi output models not to exceed nominal power Dimensions 4.0 (101.6) 3.75 (95.3) J1 AC IN 1 J2 1 OUT PE 6 FG Pillars (not included) for connection to protective earth (PE) Height: 0.2 min. (5.0), Diam.: 0.25 max. (6.0) To comply with EN 55022 class B: Field ground (FG) and protective earth (PE) are to be connected to chassis () = mm 128 0.09(2.3) 1.75 (44.5) 1.18(30.0) 2.0 (50.8) www.tracopower.com Open Frame Design AC/DC Power Supplies CB T0P-100 Series 100 W Scheme CSA C22.2 UL 60950-1 Low profile 2.0” x 4.0” footprint Full load operation up to +50°C with convection cooling High efficiency of 90% typ. Operating temperature range –25 °C to +70 °C Compliance with EN 61000-3-2 Safety class I and class II Optional case version Specifications Models open frame Order code Output power Output voltage Output current Input voltage range 90–132 VAC / 187–264 VAC (autorange) 47-63 Hz max. max. Line regulation 0.5 % max. TOP 100-105 5 VDC 20 A Load regulation 1.0 % max. TOP 100-112 12 VDC 8.3 A Output voltage approx. +5 % of Vout nom. by internal potentiometer TOP 100-115 100 W 15 VDC 6.7 A adjustment TOP 100-124 24 VDC 4.2 A Ripple & noise <100 mVpk-pk TOP 100-148 48 VDC 2.1 A (20 MHz BW) <200 mVpk-pk for 48 V models EMI emission EN 55011/22 class B, harmonic current EN 61000-3-2 EMC immunity EN61000-6-1 Output current limitation >125% Inom. foldback, automatic recovery Efficiency 90 % typ. Models chassis cover Operating temperature –25 ° C to +70 ° C (convection cooling) Order code Output power Output voltage Output current max. max. derating 2.0 %/K above 50 ° C, TOP 100-105C 5 VDC 20 A for 3.3 & 5.0 VDC models: 2.0 %/K above 40 ° C TOP 100-112C 12 VDC 8.3 A Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report TOP 100-115C 100 W 15 VDC 6.7 A approvals TOP 100-124C 24 VDC 4.2 A Degree of protection class I, class II prepared with second fuse TOP 100-148C 48 VDC 2.1 A Full datasheet www.tracopower.com/products/top100.pdf Dimensions 4.0 (101.6) 3.75 (95.3) J1 AC IN 1 J2 1 OUT Field Ground 4x ø 0.157 (4.0) 6 4x Pillars (not included) for connection to safety earth: Height: 0.2 min. (5.0), Diam.: 0.25 max. (6.0) To comply with EN 55022 class B: Field ground (FG) is to be connected to chassis () = mm 129 0.14 (3.6) 1.75 (44.5) 2.0 (50.8) 1.25 (31.8) www.tracopower.com AC/DC Power Supplies Open Frame Design CB TPI-100 Series 100 W UL 60950-1 UL 508 Scheme Highest power density open frame 100 W power supply in 2” x 3” package Ready to meet ErP directive, < 0.3 W no load power consumption Highest efficiency 91 to 92% across 10% – 100% load range Active power factor correction (>95) Protection class II prepared Operating up to 5000 m altitude Optional case version Specifications Models Order code Output power Output voltage Output current Input voltage range universal input 85-264VAC max. max. Line regulation 0.2 % max. TPI 100-112A-J 12 VDC 8.34 A Load regulation 0.5 % max. TPI 100-115A-J 15 VDC 6.67 A Output voltage approx. +5 % of Vout nom. by internal potentiometer TPI 100-124A-J 100 W 24 VDC 4.17 A adjustment TPI 100-136A-J 36 VDC 2.78 A Ripple & noise 120 – 340 mVpk-pk depending on model TPI 100-148A-J 48 VDC 2.09 A (20 MHz BW) with external capacitor on demand: case version EMI emission EN 55011/22 class B, harmonic current EN 61000-3-2 EMC immunity EN61000-6-2 Output current limitation >125% Inom. foldback, automatic recovery Efficiency 91 % typ. Operating temperature –40 ° C to +80 ° C (convection cooling) derating 2.0 %/K above 50 ° C Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report approvals Degree of protection class II prepared Full datasheet www.tracopower.com/products/tpi100.pdf Dimensions () = mm 130 NEW Product www.tracopower.com Open Frame Design AC/DC Power Supplies CB TPI-150 Series 150 W UL 60950-1 UL 508 Scheme Highest power density open frame 150 W power supply in 2” x 4” package EN 55022 without ground plane Ready to meet ErP directive, < 0.3 W no load power consumption Highest efficiency 91 to 92% across 10% – 100% load range Active power factor correction (>95) Protection class II prepared Operating up to 5000 m altitude Order code Output power Output voltage Output current Input voltage range universal input 85-2640VAC max.* max. Line regulation 0.2 % max. TPI 150-112A-J 12 VDC 12.5 A Load regulation 0.5 % max. TPI 150-115A-J 15 VDC 10.0 A Output voltage approx. +5 % of Vout nom. by internal potentiometer TPI 150-124A-J 150 W 24 VDC 6.25 A adjustment TPI 150-136A-J 36 VDC 4.17 A Ripple & noise 120 – 250 mVpk-pk depending on model TPI 150-148A-J 48 VDC 3.13 A (20 MHz BW) with external capacitor * for 100-150 W operation forced air cooling with 10 CFM is required EMI emission EN 55011/22 class B, harmonic current EN 61000-3-2 EMC immunity EN61000-6-2 Output current limitation >125% Inom. foldback, automatic recovery Efficiency 91 % typ. Operating temperature –40 ° C to +80 ° C (convection cooling) derating 2.0 %/K above 50 ° C Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report approvals Degree of protection class II prepared Full datasheet www.tracopower.com/products/tpi150.pdf Dimensions () = mm 131 NEW Product www.tracopower.com AC/DC Power Supplies Open Frame Design CB T0P-200 Series 200 W Scheme UL 60950-1 High power density in 3.0” x 5.0” footprint Supplies 200 W (without fan!) Highest efficiency of 90% typ. Operating temperature range –25 °C to +70 °C Universal input 85–264 VAC Compliance with EN 61000-3-2 Protection class I and class II Optional case version Specifications Models Order code Output power Output voltage Output current Input voltage range 85–264 VAC, 47–63 Hz max. max. Line regulation 0.5 % max. TOP 200-112(C) 12 VDC 16 A Load regulation 1.0 % max. TOP 200-115(C) 200 W 15 VDC 13 A Ripple & noise <120 mVpk-pk for other models TOP 200-124(C) 24 VDC 8.3 A (20 MHz BW) <150 mVpk-pk for 48 VDC models TOP 200-148(C) 48 VDC 4.2 A EMI emission EN 55011/22 class B, harmonic current EN 61000-3-2 * with suffix C: case version EMC immunity EN 61000-6-1 Output current limitation >110 % of Iout max. Efficiency 90 % typ. Overvoltage protection >130 % of Vout nom. Operating temperature –25 ° C to +70 ° C (convection cooling) derating 2.0 %/K above 40° C for 12 & 15 VDC models derating 2.0 %/K above 50° C for 24 & 48 VDC models Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report approvals Degree of protection class I, class II prepared Full datasheet www.tracopower.com/products/top200.pdf Dimensions 5.0 (127.0) 4.71 (119.5) J2 PE 1 OUT J1 1 AC IN J3 1 On/Off Field Ground 4x ø 0.137 (3.5) 4 x metal pillars (not included) for connection to conductive plate in order to meet EN55022 class B () = mm Minimum height: 0.2 (5.0), max. diameter: 0.25 (6.0) 132 0.14 (3.6) 2.72 (69.1) 3.0 (76.2) 1.34 (34.0) www.tracopower.com Encapsulated Modules AC/DC Power Supplies CB TMSB-2 Series 2 W UL 60950-1 UL 508 Scheme Standby power module to comply with ErP directive; no load input power < 30mW EN 60335 household appliance Constant power characteristics at 2W (no current limitation) Suitable to drive relays, selenoids, capacitive loads and LED’s Constant voltage auxiliary outputs 3.3 and 5 VDC Operating temperature range –30°C to +70°C EMI meets EN 55022, class B Specifications Models Order code Output power Output 1 Output 2 Input voltage range 85–264 VAC, 47–63 Hz max. Line regulation Output 1: 1.0 % TMSB 2-108 8 VDC / 250 mA ––– Output 2: 0.3% TMSB 2-114 14 VDC / 143 mA ––– Load regulation Output 1: 1.0 % TMSB 2-124 24 VDC / 83 mA ––– Output 2: 0.5% 1) 1) TMSB 2-283 2 W 8 VDC / 250 mA 3.3 VDC / 160 mA Ripple & noise Output 1: 1 % of Vout [Vp-p] typ. 1) 1) TMSB 2-285 8 VDC / 250 mA 5.0 VDC / 250 mA (20 MHz BW) Output 2: 0.1 % of Vout [Vp-p] typ. 2) 2) TMSB 2-2143 14 VDC / 143 mA 3.3 VDC / 70 mA EMI emission EN 55022 class B 2) 2) TMSB 2-2145 14 VDC / 143 mA 5.0 VDC / 83 mA EMC immunity EN 61000-6-1 1) Total output current must not exceed 250 mA Efficiency 72 % typ. 2) Total output current must not exceed 143 mA Operating temperature –30 ° C to +70 ° C (convection cooling) Output characteristics (single output) derating 2.0 %/K above 60° C constant voltage constant power area Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, EN 60335, CB-report 10 approvals 8 Full datasheet www.tracopower.com/products/tmsb2.pdf 6 4 2 0 0 100 200 300 400 500 600 700 800 900 Output Current (mA) Output characteristics (dual output) constant voltage (cv) constant power (cp) 8 150mA 200mA 250mA constant load on Vout 2 5.3 VDC 100mA 50mA No load Dimensions Area where Vout 2 equals Vout 1- 0.3V 23 4 0 800 5 Output current (mA) Bottom view Pin Single output Dual output 6 1 1 No con. No con. 7 2 No con. No con. 3 + Vout + Vout 1 14.8 (0.58) 4.0 3.00 21.00 (0.83) 4 – Vout Common (0.16) (0.12) 5 No pin + Vout 2 28.4 (1.12) 6 AC(N) AC(N) 7 AC(L) AC(L) () = Inches 133 NEW Product 7.50 25.25 (0.99) (0.30) 3.75 7.50 14.00 2x3.75 (0.15) (0.30) (0.55) (2x0.15) 36.5 (1.44) Output voltage Vout 1 (VDC) Output Voltage (VDC) Vout 2 voltage: Vout 1- 0.3V Vout 2 = nominal www.tracopower.com AC/DC Power Supplies Encapsulated Modules TMPS-03 Series 3 W CB UL 60950-1 Scheme UL 60950-1 UL 508 Compact 1” x 1” package EN 60335 household appliance Standby power module to comply with ErP directive; no load input power < 300mW Operating temperature range –25°C to +70°C EMI meets EN 55022, class B Short circuit and overload protection Peak current +30% Protection class II prepared Specifications Models Order code Out. power Out. voltage Nom. current Output current Input voltage range 85–264 VAC, 47–63 Hz max. max.* Line regulation 1.0 % max. TMPS 03-103 3.3 VDC 900 mA 1170 mA Load regulation 1.0 % max. TMPS 03-105 5.0 VDC 600 mA 780 mA Ripple & noise 1% of Vout nom. TMPS 03-109 3 W 9.0 VDC 333 mA 430 mA (20 MHz BW) TMPS 03-112 12 VDC 250 mA 320 mA EMI emission EN 55022 class B TMPS 03-115 15 VDC 200 mA 260 mA EMC immunity EN 61000-6-1 TMPS 03-124 24 VDC 125 mA 160 mA Efficiency 75 % typ. * < 30s with maximum duty cycle of 10% average output power must not exceed 3W Operating temperature –25 ° C to +70 ° C (convection cooling) derating 5.0 %/K above 60° C Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, EN 60335 approvals Full datasheet www.tracopower.com/products/tmps03.pdf Dimensions Pin 1 AC(N) 2 AC(L) 25.4 (1.00) 5.08 15.3 (0.60) 3 No con. 20.3 (0.80) (0.20) 2.54 (0.10) 4 – Vout 5 + Vout 3 4 2 1 5 () = Inches 134 NEW Product 25.4 (1.00) 2.54 5.08 (0.10) (0.20) 10.16 10.16 (0.40) (0.40) 25.4 (1.00) Ø 0.6 (Ø 0.02) www.tracopower.com Encapsulated Modules AC/DC Power Supplies TMPS-05 Series 5 W CB UL 60950-1 UL 60950-1 UL 508 Scheme Compact 1” x 1” package EN 60335 household appliance Standby power module to comply with ErP directive; no load input power < 300mW Operating temperature range –25°C to +70°C EMI meets EN 55022, class B Short circuit and overload protection Peak current +30% Protection class II prepared Specifications Models Order code Out. power Out. voltage Nom. current Output current Input voltage range 85–264 VAC, 47–63 Hz max. max.* Line regulation 1.0 % max. TMPS 05-103 3.3 VDC 1515 mA 1970 mA Load regulation 1.0 % max. TMPS 05-105 5.0 VDC 1000 mA 1300 mA Ripple & noise 1% of Vout nom. TMPS 05-109 9.0 VDC 555 mA 721 mA (20 MHz BW) TMPS 05-112 5 W 12 VDC 416 mA 540 mA EMI emission EN 55022 class B TMPS 05-115 15 VDC 333 mA 433 mA EMC immunity EN 61000-6-1 TMPS 05-124 24 VDC 208 mA 270 mA Efficiency 81 % typ. TMPS 05-148 48 VDC 104 mA 135 mA * < 30s with maximum duty cycle of 10% Operating temperature –25 ° C to +70 ° C (convection cooling) average output power must not exceed 5W derating 2.5 %/K above 50° C Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, EN 60335 approvals Full datasheet www.tracopower.com/products/tmps05.pdf Dimensions Pin 1 AC(N) 2 AC(L) 25.4 (1.00) 5.08 15.3 (0.60) 3 No con. (0.20) 20.3 (0.80) 2.54 (0.10) 4 – Vout 3 5 + Vout 4 2 1 5 () = Inches 135 NEW Product 25.4 (1.00) 5.08 2.54 (0.10) (0.20) 10.16 10.16 (0.40) (0.40) 25.4 (1.00) Ø 0.6 (Ø 0.02) www.tracopower.com AC/DC Power Supplies Encapsulated Modules CB TMS Series 6 to 25 W Scheme UL 60950-1 Miniature encapsulated power supplies 3 package styles available: – for PCB mount with solder pins – for chassis mount with FASTON-tabs – for chassis mount with screw terminal block Universal input 85–264 VAC EMI meets 55022, class B Short circuit protection Specifications Models Input voltage range 85–264 VAC, 47-63 Hz Order code* Output power Output 1 Output 2 110–375 VDC TMS 06105 5 VDC / 1200 mA Line regulation 0.4 % max. TMS 06112 12 VDC / 500 mA Load regulation 1.0 % max. for single output models TMS 06115 6 W 15 VDC / 400 mA 2.0 % max. for dual output models TMS 06124 24 VDC / 250 mA Ripple & noise <100 mVpk-pk (20 MHz BW) TMS 06212 +12 VDC / 250 mA –12 VDC / 250 mA EMI suppression EN 55011 class B, EN 55022 class EN55022 class B TMS 06215 +15 VDC / 200 mA –15 VDC / 200 mA EMC immunity EN61000-6-1 TMS 10105 5 VDC / 2000 mA Output current limitation >130 % Iout max., foldback, automatic recovery TMS 10112 12 VDC / 900 mA TMS 10115 10 W 15 VDC / 700 mA Efficiency 78 % typ. TMS 10124 24 VDC / 450 mA Operating temperature –25 ° C to +60 ° C above 50 ° C derating 5 %/K TMS 10212 +12 VDC / 450 mA –12 VDC / 450 mA 5 Vout models: above 40 ° C derating 2.5 %/K TMS 10215 +15 VDC / 350 mA –15 VDC / 350 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 CB-report TMS 15105 5 VDC / 3000 mA approvals TMS 15112 12 VDC / 1300 mA Degree of protection safety class l TMS 15115 15 W 15 VDC / 1000 mA TMS 15124 24 VDC / 650 mA Casing plastic (UL 94V-0 rated) TMS 15212 +12 VDC / 650 mA –12 VDC / 650 mA Full datasheet www.tracopower.com/products/tms.pdf TMS 15215 +15 VDC / 500 mA –15 VDC / 500 mA TMS 25105 5 VDC / 4600 mA TMS 25112 12 VDC / 2000 mA TMS 25115 25 W 15 VDC / 1600 mA TMS 25124 24 VDC / 1000 mA TMS 25212 +12 VDC / 1000 mA –12 VDC / 1000 mA TMS 25215 +15 VDC / 800 mA –15 VDC / 800 mA * For PCB mount version - no suffix For chassis mount with Faston-Tabs add suffix F (not for 6 W models) For chassis mount with screw terminal block add suffix C (not for 6 & 10W models) Dimensions PCB mount version Chassis mount with Faston-tabs Chassis mount with screw terminal block (no suffix) (suffix F) (suffix C) Type Length l Width w Height h TMS 06 50 (1.97) 40 (1.57) 20 (0.79) 1 2 3 TMS 10 55 (2.17) 45 (1.77) 24 (0.94) TMS 15 64 (2.52) 45 (1.77) 24 (0.94) TMS 25 76 (2.99) 51 (2.01) 28 (1.10) Bottom view Top view Top view TMS 10F 75 (2.95) 45 (1.77) 24 (0.94) TMS 15F 84 (3.31) 45 (1.77) 24 (0.94) TMS 25F 96 (3.78) 51 (2.01) 29 (1.14) TMS 15C 84 (3.31) 45 (1.77) 26.5 (1.04) 5 6 4 TMS 25C 96 (3.78) 51 (2.01) 29.5 (1.16) w h h w w () = Inch 136 l l l www.tracopower.com Encapsulated Modules AC/DC Power Supplies CB TMP & TMPM Series 4 to 10 W Scheme UL 60950-1 Fully encapsulated low profile plastic casing Single and dual output models Meets ErP directive (green mode), <0.3 W no load power consumption, high efficiency across full load range Universal input 85–264 VAC, 47–440 Hz Protection against short circuit, overload and over-temperature EMI meets 55022, class B Specifications Models Order code Output power Output 1 Output 2 Input voltage range 85–264 VAC, 47–440 Hz 120-370 VDC TMPM 04103 3.3 VDC / 1200 mA Line regulation 1.0 % max. TMPM 04105 5.0 VDC / 800 mA 3.0 % typ. output 2 TMPM 04109 9.0 VDC / 444 mA TMPM 04112 12 VDC / 333 mA Load regulation 1.0 % typ. output 1 2.5 % typ. output 2 TMPM 04115 4 W 15 VDC / 267 mA TMPM 04124 24 VDC / 167 mA Ripple & noise <1.8 % of Vout nom. for 3.3 & 5 VDC outputs TMPM 04212 +12 VDC / 166 mA -12 VDC / 166 mA (20 MHz BW) <1.0 % of Vout nom. for other outputs TMPM 04215 +15 VDC / 133 mA -15 VDC / 133 mA EMI suppression EN 55022 class EN55022 class B TMPM 04253 +5.0 VDC / 600 mA +3.3 VDC / 150 mA EMC immunity EN61000-6-2 TMPM 04225 +12 VDC / 250 mA +5.0 VDC / 120 mA Output current limitation >105% Inom. foldback, automatic recovery TMP 07103 4.6 W 3.3 VDC / 1400 mA TMP 07105 5.0 VDC / 1400 mA Efficiency 78 % typ. TMP 07112 7 W 12 VDC / 585 mA Operating temperature –25 ° C to +60 ° C TMP 07115 15 VDC / 465 mA above 40 ° C derating 2.5 %/K TMP 07124 24 VDC / 290 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report, TMPM 10103 8.6 W 3.3 VDC / 2500 mA approvals TMPM 10105 5.0 VDC / 2000 mA Degree of protection safety class II prepared TMPM 10112 10 W 12 VDC / 830 mA Casing plastic (UL 94V-0 rated) TMPM 10115 15 VDC / 665 mA Full datasheet www.tracopower.com/products/tmp.pdf TMPM 10124 24 VDC / 415 mA TMP 10103 6.6 W 3.3 VDC / 2000 mA TMP 10105 5.0 VDC / 2000 mA Dimensions TMP 10112 12 VDC / 830 mA TMP 10115 10 W 15 VDC / 665 mA TMPM 04 Models: TMP 10124 24 VDC / 415 mA TMP 10212 +12 VDC / 380 mA -12 VDC / 380 mA NC Vout 1 TMP 10215 +15 VDC / 300 mA -15 VDC / 300 mA GND NC/Vout 2 Bottom view AC NC AC 3.00 21.00 (0.83) 17.1 (0.67) 4.0 (0.12) (0.16) 27.0 (1.06) TMP 10 Models: TMP 07 Models: TMPM 10 Models: 45.0 (1.77) 10.16 10.16 19.0 (0.75) (0.40) (0.40) 27.2 (1.07) 25.4 (1.00) 23.5 (0.93) 10.16 3.45 19.3 (0.76) 10.16 2.54 (0.40) (0.14) +Vout NC/GND -Vout (0.40) (0.10) -Vout +Vout -Vout +Vout Bottom view Bottom view Bottom view AC AC AC AC AC AC 0.7 (0.03) 10.0 20.32 (0.80) 0.56 (0.02) .0 20.32 (0.80) 17.78 (0.70) 22.5 (0.89) 0.56 (0.02) .0 (0.24) (0.39) (0.24) () = Inches 137 7.50 25.25 (0.99) (0.30) 45.72 (1.80) 2.54 (0.10) 50.80 (2.00) 3.75 7.50 14.00 2x3.75 (0.15) (0.30) (0.55) (2x0.15) 36.5 (1.44) 5.0 5.0 (0.20) (0.20) 45.72 (1.80) 3.35 (0.13) 52.4 (2.06) 5.0 5.0 (0.20) (0.20) 4.0 54.0 (2.13) (0.16) 64.0 (2.52) 5.0 5.0 (0.20) (0.20) www.tracopower.com AC/DC Power Supplies Encapsulated Modules CB TMP Series 15 to 60 W Scheme UL 60950-1 UL 508 Fully encapsulated low profile plastic casing PCB mount Single-, dual- and triple output models Universal input 85–264 VAC, 47–440 Hz Protection class II prepared EMI meets 55022, class B Protection against short circuit, overload and over-temperature Specifications Models Order code* Output power Output 1 Output 2/3 Input voltage range 85–264 VAC, 47–440 Hz (47-63 Hz for 60 W models) TMP 15105 5.0 VDC / 3000 mA 120-370 VDC TMP 15112 12 VDC / 1250 mA Line regulation 1.0 % max. TMP 15115 15 VDC / 1000 mA Load regulation 1.0 % typ. output 1 TMP 15124 24 VDC / 625 mA 3.0 % typ. output 2 & 3 TMP 15148 15 W 48 VDC / 310 mA Ripple & noise <2% of Vout nom. for 5 VDC outputs TMP 15212 +12 VDC / 650 mA -12 VDC / 650 mA (20 MHz BW) <1.3 % of Vout nom. for other outputs TMP 15215 +15 VDC / 500 mA -15 VDC / 500 mA EMI suppression EN 55011 class B, EN 55022 class B TMP 15252 +5.0 VDC / 1500 mA +12 VDC / 625 mA EMC immunity EN61000-6-1 TMP 15512 +5.0 VDC / 2000 mA +12 VDC / 200 mA Output current limitation >105% Inom. foldback, automatic recovery -12 VDC / 200 mA Efficiency 80 % typ. TMP 15515 +5.0 VDC / 2000 mA +15 VDC / 150 mA Operating temperature –25 ° C to +65 ° C -15 VDC / 150 mA above 50 ° C derating 3.3 %/K TMP 30105 5.0 VDC / 6000 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, CB-report TMP 30112 12 VDC / 2500 mA approvals TMP 30115 15 VDC / 2000 mA Degree of protection safety class II prepared TMP 30124 24 VDC / 1250 mA Casing plastic (UL 94V-0 rated) TMP 30148 48 VDC / 625 mA Full datasheet www.tracopower.com/products/tmp.pdf TMP 30212 +12 VDC / 1300 mA -12 VDC / 1300 mA TMP 30215 +15 VDC / 1000 mA -15 VDC / 1000 mA TMP 30252 +5.0 VDC / 3000 mA +12 VDC / 1250 mA TMP 30512 30 W +5.0 VDC / 3000 mA +12 VDC / 600 mA -12 VDC / 600 mA TMP 30515 +5.0 VDC / 3000 mA +15 VDC / 500 mA -15 VDC / 500 mA TMP 30522 +5.0 VDC / 1500 mA +12 VDC / 1000 mA Dimensions -12 VDC / 250 mA TMP 30316 +3.3 VDC / 4000 mA +5.0 VDC / 1500 mA Type Length l Width w Height h +12 VDC / 250 mA PCB mount TMP 15xxx 74.0 (2.91) 54.0 (2.13) 19.3 (0.76) TMP 30317 +5.0 VDC / 4500 mA +3.3 VDC / 1000 mA TMP 30xxx 89.0 (3.50) 63.5 (2.50) 21.5 (0.85) +12 VDC / 250 mA TMP 60xxx 89.0 (3.50) 67.5 (2.66) 34.0 (1.34) TMP 60105 5.1 VDC / 10‘000 mA TMP 60112 12 VDC / 5000 mA TMP 60115 60 W 15 VDC / 4000 mA TMP 60124 24 VDC / 2500 mA TMP 60136 36 VDC / 1670 mA TMP 60148 48 VDC / 1250 mA Bottom view (Top view) h w wh () = Inches 138 l l www.tracopower.com Encapsulated Modules AC/DC Power Supplies CB TMP-C Series 15 to 60 W UL 60950-1 UL 508 Scheme Fully encapsulated low profile plastic case For DIN-rail mount or chassis mount Screw terminal block Single-, dual- and triple output models Universal input 85–264 VAC, 47–440 Hz UL 508 listed Protection class II Protection against short circuit, overload and over-temperature Power-good LED indicator Specifications Models Order code Output power Output 1 Output 2/3 Input voltage range 85–264 VAC, 47–440 Hz (47-63 Hz for 60 W models) TMP 15105C 5.0 VDC / 3000 mA 120-370 VDC TMP 15112C 12 VDC / 1250 mA Line regulation 1.0 % max. TMP 15115C 15 VDC / 1000 mA Load regulation 1.0 % typ. Output 1 TMP 15124C 24 VDC / 625 mA 3.0 % typ.Output 2 & 3 TMP 15148C 15 W 48 VDC / 310 mA Ripple & noise <2% of Vout nom. for 5 VDC outputs TMP 15212C +12 VDC / 650 mA -12 VDC / 650 mA (20 MHz BW) <1.3 % of Vout nom. for other outputs TMP 15215C +15 VDC / 500 mA -15 VDC / 500 mA EMI suppression EN 55011 class B, EN 55022 class EN55022 class B TMP 15252C +5.0 VDC / 1500 mA +12 VDC / 625 mA EMC immunity EN61000-6-1 TMP 15512C +5.0 VDC / 2000 mA +12 VDC / 200 mA Output current limitation >105% Inom. foldback, automatic recovery -12 VDC / 200 mA Efficiency 80 % typ. TMP 15515C +5.0 VDC / 2000 mA +15 VDC / 150 mA Operating temperature –25 ° C to +65 ° C -15 VDC / 150 mA above 50 ° C derating 3.3 %/K TMP 30105C 5.0 VDC / 6000 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, UL 508 (single output and TMP 30112C 12 VDC / 2500 mA approvals symetric dual output models only), CB-report TMP 30115C 15 VDC / 2000 mA Degree of protection class II TMP 30124C 24 VDC / 1250 mA Casing plastic (UL 94V-0 rated) TMP 30148C 48 VDC / 625 mA Full datasheet www.tracopower.com/products/tmp.pdf TMP 30212C +12 VDC / 1300 mA -12 VDC / 1300 mA TMP 30215C +15 VDC / 1000 mA -15 VDC / 1000 mA TMP 30252C +5.0 VDC / 3000 mA +12 VDC / 1250 mA Dimensions TMP 30512C 30 W +5.0 VDC / 3000 mA +12 VDC / 600 mA -12 VDC / 600 mA Type Length l Width w Height h TMP 30515C +5.0 VDC / 3000 mA +15 VDC / 500 mA TMP 15xxxC 96 (3.78) 54.0 (2.13) 23.3 (0.88) -15 VDC / 500 mA TMP 30xxxC 112 (4.41) 63.8 (2.51) 25.6 (1.01) TMP 30522C +5.0 VDC / 1500 mA +12 VDC / 1000 mA TMP 60xxxC 112 (4.41) 67.8 (2.67) 38.0 (1.50) -12 VDC / 250 mA TMP 30316C +3.3 VDC / 4000 mA +5.0 VDC / 1500 mA +12 VDC / 250 mA TMP 30317C +5.0 VDC / 4500 mA +3.3 VDC / 1000 mA +12 VDC / 250 mA TMP 60105C 5.1 VDC / 10‘000 mA (Top view) TMP 60112C 12 VDC / 5000 mA TMP 60115C 60 W 15 VDC / 4000 mA TMP 60124C 24 VDC / 2500 mA TMP 60136C 36 VDC / 1670 mA TMP 60148C 48 VDC / 1250 mA wh DIN-rail mount adapter TMP-MK1 for 15 W version TMP-MK2 for 30 W and 60 W versions () = Inches 139 l www.tracopower.com AC/DC Power Supplies Encapsulated Modules CB TMLM Series 4 to 20 W LVD UL 60950-1 UL 60950-1 UL 508 Scheme Ultra compact 20 W in 2“ x 1“ package Fully encapsulated modules for PCB mount Universal input 90–264 VAC, 47–440 Hz TMLM04 with extended input range 85-305 VAC EMI meets EN 55022, class B Low ripple and noise Short circuit and overload protection Protection class II prepared Specifications Specifications Models Models Output Input voltage range 90–264 VAC, 47–440 Hz Order code Output 1 Output 2 power 120-370 VDC TMLM 04103* 4 W 3.3 VDC / 1200 mA Line regulation 0.3 % max. TMLM 04105* 4 W 5.0 VDC / 800 mA Load regulation 0.5 % typ. TMLM 04109* 4 W 9.0 VDC / 444 mA Ripple & noise <1.0 % of Vout TMLM 04112* 4 W 12 VDC / 333 mA (20 MHz BW) <1.5 % of Vout for 3.3 & 5 VDC models TMLM 04115* 4 W 15 VDC / 267 mA EMI suppression EN 55011 class B, EN 55022 class EN55022 class B TMLM 04124* 4 W 24 VDC / 167 mA EMC immunity EN61000-6-1 TMLM 04253* 3.5 W +5.0 VDC / 600 mA +3.3 VDC / 150 mA Output current limitation foldback, automatic recovery TMLM 04225* 3.6 W +12 VDC / 250 mA +5.0 VDC / 120 mA TMLM 05103 4.1 W 3.3 VDC / 1250 mA Efficiency 78 % typ. TMLM 05105 5 W 5.0 VDC / 1000 mA Operating temperature –25 ° C to +60 ° C TMLM 04 models: above 50 ° C derating 3.75 %/K TMLM 05112 5 W 12 VDC / 420 mA other models: above 40 ° C derating 2.5 %/K TMLM 05115 5 W 15 VDC / 330 mA Safety standards / cUL/UL 60950-1, EN 60950-1 TMLM 05124 5.5 W 24 VDC / 230 mA approvals TMLM 10103 8.2 W 3.3 VDC / 2500 mA Degree of protection class II prepared TMLM 10105 10 W 5.0 VDC / 2000 mA TMLM 10112 10 W 12 VDC / 830 mA Casing plastic (UL 94V-0 rated) TMLM 10115 10 W 15 VDC / 665 mA Full datasheet www.tracopower.com/products/tmlm.pdf TMLM 10124 10 W 24 VDC / 420 mA TMLM 20103 12 W 3.3 VDC / 3600 mA Dimensions TMLM 20105 18 W 5.0 VDC / 3600 mA TMLM 20112 20 W 12 VDC / 1670 mA TMLM 04 Models: TMLM 20115 20 W 15 VDC / 1330 mA Pin Single output Dual output TMLM 20124 20 W 24 VDC / 830 mA * Add suffix -EI for extended input range version (85-305 VAC) 1 No con. No con. 5 4 3 2 + Vout Vout 1 6 2 3 – Vout Common 4 No con. Vout 2 5 AC AC 7 1 6 AC AC 3.0 21.0 (0.83) 17.1 4.0 7 No con. No con. (0.67) (0.16) (0.12) 27.0 (1.06) TMLM 05 Models: TMLM 10 Models: TMLM 20 Models: 10.16 10.16 10.2 (0.40) (0.40) (0.40) M3 THD M3 THD 15.2 8.0 4.50 23.5 (0.93) 8.0 4.50 23.5 (0.93) 8.0 2.6 20.3 (0.80) (0.60) (0.31) (0.18) (0.31) (0.18) (0.31) (0.81) 3.5 20.32 (0.80) 3.5 20.32 (0.80) 25.5 (1.00) (0.13) (0.13) 27.3 (1.07) 27.3 (1.07) () = Inches 140 AC Bottom view – Vout Bottom view AC +Vout 45.7 (1.80) 3.4 3.75 21.5 (0.85) 2 x 3.75 (0.15) (2 x 0.15) (0.13) 36.5 (1.44) 50.9 (2.00) AC Bottom view – Vout AC +Vout 13.65 (0.54) 45.72 (1.80) 3.4 (0.13) 52.5 (2.07) AC Bottom view – Vout AC +Vout 13.65 (0.54) 45.72 (1.80) 3.4 (0.13) 52.5 (2.07) www.tracopower.com Encapsulated Modules AC/DC Power Supplies CB TML Series 20 to 40 W Scheme UL 60950-1 2 Package styles available: – for PCB mount with solder pins – for chassis mount with screw terminal block Single-, dual- and triple output models Universal input 90–264 VAC, 47–440 Hz Protection class I (TML 20) and class II (TML 40) EMI meets EN 55022, class B Short circuit and overload protection Specifications Models Input voltage range 90–264 VAC, 47–440 Hz Order code* Output power Output 1 Output 2/3 100-370 VDC TML 20103 3.3 VDC 4500 mA Line regulation 1.0 % max. for output 1 TML 20105 5 VDC 4000 mA 5.0 % max. for output 2/3 TML 20112 12 VDC 1670 mA Load regulation 1.0 % max. for single output models TML 20115 15 VDC 1340 mA 2.0 % max. for output 1, 7.0 % max. for output 2/3 TML 20124 20 W 24 VDC 840 mA Ripple & noise <1.0 % of Vout TML 20205 +5 VDC 2000 mA –5 VDC 2000 mA (20 MHz BW) <1.5 % of Vout for 3.3 & 5 VDC models TML 20212 +12 VDC 830 mA –12 VDC 830 mA EMI suppression EN 55011 class B, EN 55022 class EN55022 class B TML 20215 +15 VDC 670 mA –15 VDC 670 mA EMC immunity EN61000-6-1 TML 20512 5 VDC 2800 mA ±12 VDC ±250 mA Output current limitation foldback, automatic recovery TML 20515 5 VDC 2800 mA ±15 VDC ±200 mA Efficiency 80 % typ. TML 40103 3.3 VDC 8000 mA Operating temperature –25 ° C to +60 ° C TML 40105 5 VDC 8000 mA above 50 ° C derating 4 %/K TML 40112 12 VDC 3330 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 CB-report TML 40115 15 VDC 2670 mA approvals TML 40124 24 VDC 1670 mA Degree of protection safety class I (TML 40 W models safety class II) TML 40205 40 W +5 VDC 4000 mA –5 VDC 4000 mA Casing plastic (UL 94V-0 rated) TML 40212 +12 VDC 1670 mA –12 VDC 1670 mA TML 40215 +15 VDC 1330 mA –15 VDC 1330 mA Full datasheet www.tracopower.com/products/tml.pdf TML 40252 5 VDC 5000 mA 12 VDC 1250 mA TML 40254 5 VDC 5000 mA 24 VDC 625 mA TML 40512 5 VDC 5000 mA ±12 VDC ±600 mA TML 40515 5 VDC 5000 mA ±15 VDC ±500 mA * For chassis mount version add suffix C DIN-rail mount adapter TMP-MK1 for 20 W chassis mount version TMP-MK2 for 40 W chassis mount version Type Length l Width w Height h PCB mount TML 20xxx 70.0 (2.76) 48.0 (1.89) 22.0 (0.87) PCB Mount Version Chassis Mount with Screw Terminals TML 40xxx 89.0 (3.50) 63.5 (2.50) 25.0 (0.98) Chassis mount TML 20xxxC 96.0 (3.78) 54.6 (2.15) 27.5 (1.08) TML 40xxxC 112.9 (4.44) 64.7 (2.55) 31.5 (1.24) () = Inch 141 www.tracopower.com AC/DC Power Supplies Encapsulated Modules CB TMT Series 10 to 50 W Scheme UL 60950-1 UL 508 UL 60601-1 Industrial (UL508) and medical safety approvals 2 packages styles available: – PCB mount with solder pins – Chassis mount with screw terminal block Adapter for DIN-rail mount Single-, dual- and triple output models Universal input 85 – 264 VAC Short circuit and overload protection Specifications Models Order code Output power Output 1 Output 2/3 Input voltage range 85–264 VAC, 47–63 Hz 85–370 VDC (derating below 110 VDC input) TMT 10105 5 VDC / 2000 mA Line regulation 0.4 % max. TMT 10112 10 W 12 VDC / 840 mA Load regulation 1.0 % max. for single output models TMT 10115 15 VDC / 670 mA 3.0 % max. for multi output models TMT 10124 24 VDC / 420 mA Ripple & noise <150 mVpk-pk (20 MHz BW) *TMT 15105 5 VDC / 3000 mA EMI suppression EN 55011 class B, EN 55022 class EN55022 class B *TMT 15112 12 VDC / 1250 mA *TMT 15115 15 W 15 VDC / 1000 mA EMC immunity EN 60601-1-2 *TMT 15124 24 VDC / 625 mA Output current limitation >105% Inom. foldback, automatic recovery *TMT 15212 +12 VDC / 625 mA -12 VDC / 625 mA Efficiency 83 % typ. *TMT 15215 +15 VDC / 500 mA -15 VDC / 500 mA Operating temperature –25 ° C to +50 ° C *TMT 30105 5 VDC / 6000 mA above 40 ° C derating 5 %/K *TMT 30112 12 VDC / 2500 mA Safety standards / cUL/UL 60950-1, IEC/EN 60950-1, UL 60601-1, IEC/EN 60601-1, *TMT 30115 15 VDC / 2000 mA approvals CB-report, UL 508 listed (chassis mount modules) *TMT 30124 24 VDC / 1250 mA Degree of protection class II prepared *TMT 30212 +12 VDC / 1250 mA -12 VDC / 1250 mA Casing plastic (UL 94V-0 rated) *TMT 30215 +15 VDC / 1000 mA -15 VDC / 1000 mA Option DIN-rail mount adapter *TMT 30252 30 W 5 VDC / 3000 mA 12 VDC / 1200 mA Full datasheet www.tracopower.com/products/tmt.pdf *TMT 30522 5 VDC / 3000 mA 12 VDC / 1000 mA 12 VDC / 250 mA *TMT 30515 5 VDC / 3000 mA 15 VDC / 500 mA 15 VDC / 500 mA TMT 30503 3.3 VDC / 6000 mA 5 VDC / 1500 mA Dimensions 12 VDC / 250 mA TMT 30505 5 VDC / 5000 mA 3.3 VDC / 1000 mA 12 VDC / 250 mA *TMT 50105 5 VDC / 9000 mA *TMT 50112 12 VDC / 4200 mA *TMT 50115 50 W 15 VDC / 3400 mA Bottom view *TMT 50124 24 VDC / 2300 mA *TMT 50148 48 VDC / 1150 mA * For chassis mount version add suffix C w h DIN-rail mount adapter TMT-MK1 for 15 W TMT-MK2 for 30 W single and symetric dual TMT-MK3 for 30 W asymetric dual and tripple TMT-MK5 for 50 W Dimensions PCB mount Chassis mount (Top view) Type Length l Width w Height h Length l Width w Height h TMT 10xxx 51 (2.00) 33 (1.30) 21.6 (0.79) TMT 15xxx 55 (2.16) 45 (1.77) 24 (0.95) 77 (3.03) 45 (1.77) 26.4 (1.04) TMT 301xx 76 (2.99) 51 (2.00) 28 (1.10) 96 (3.78) 51 (2.01) 29.5 (1.16) TMT 3021x 76 (2.99) 51 (2.00) 28 (1.10) 96 (3.78) 51 (2.01) 29.5 (1.16) TMT 30252 86 (3.39) 58 (2.28) 28 (1.10) 106 (4.17) 58 (2.28) 29.5 (1.16) wh TMT 305xx 86 (3.39) 58 (2.28) 28 (1.10) 106 (4.17) 58 (2.28) 29.5 (1.16) TMT 50xxx 89 (3.50) 64 (2.52) 28 (1.10) 110 (4.33) 64 (2.52) 31.5 (1.24) () = Inch 142 l l 34.0 (1.34) www.tracopower.com Encapsulated Modules AC/DC Power Supplies CB CB Schem Schemee CB CB TMM Series 24 to 60 W UL 60950-1 UL 60950-1 UL 60950-1 Scheme UL 60950-1 UL 508 UL 60601-1 ES 60601-1 UL 60950-1 UL 508 Scheme UL 60601-1 Fully encapsulated low profile plastic (PCB mount) 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition IT and industrial safety according to IEC/EN/UL 60950-1 and UL 508 Ready to meet ErP directive <0.3W no load power consumption Operating temperature –40°C up to +60°C without derating Protection class II prepared Power-good LED indicator Specifications Models Input voltage range 85–264 VAC, 47–63 Hz Order code* Output power Output 1 Output 2 85–370 VDC (derating below 110 VDC input) TMM 24105 15 W 5.0 VDC 3000 mA Line regulation 0.5% typ. TMM 24112 12 VDC 2000 mA Load regulation Singel output: TMM 24115 24 W 15 VDC 1600 mA – 24 & 60 W models: 0.5 % typ. TMM 24124 24 VDC 1000 mA – 40 W models: 1.0% typ. TMM 24212 + 12 VDC 1000 mA – 12 VDC 1000 mA Dual output: TMM 24215 + 15 VDC 800 mA – 15 VDC 800 mA – 24 W models: 2.5% typ. – 40 W models: 2.0% typ. TMM 40105 5.0 VDC 8000 mA TMM 40112 12 VDC 3300 mA Ripple & noise 5.0 VDC models: 2% max. TMM 40115 40 W 15 VDC 2660 mA 5.1 VDC model: 3% max. other models: 1.5% max. TMM 40124 24 VDC 1660 mA EMI suppression EN 55011 class B, EN 55022 class B TMM 40212 + 12 VDC 1660 mA – 12 VDC 1660 mA TMM 40215 + 15 VDC 1330 mA – 15 VDC 1330 mA EMC immunity EN 60601-1-2, EN 61000-6-2 TMM 60105 5.1 VDC 10000 mA Output current limitation >105% Inom. foldback, automatic recovery TMM 60112 12 VDC 5000 mA Leakage current 80µA max. TMM 60115 60 W 15 VDC 4000 mA Efficiency 83 % typ. TMM 60124 24 VDC 2500 mA Operating temperature –40 ° C to +80 ° C TMM 60148 48 VDC 1250 mA above 60°C derating 3%/K Safety standards / UL 60950-1, IEC/EN 60950-1, UL508 approvals IEC/EN 60601-1 3rd edition, 2 x MOPP ANSI/AAMI ES60601-1:2005(R)2012 Degree of protection class II prepared Casing plastic (UL 94V-0 rated) Full datasheet www.tracopower.com/products/tmm24.pdf www.tracopower.com/products/tmm40.pdf www.tracopower.com/products/tmm60.pdf Dimensions TMM 24: TMM 40: TMM 60: 2 7 2 2 7 6 6 5 1 5 4 4 4 2 x M4 THD 1 1 3 3 81.3 (3.20) 81.3 (3.20) 89.0 (3.50) 88.9 (3.50) 62.0 (2.44) 74.0 (2.91) 5.0 5.0 5.0 5.0 5.0 5.0 (0.20) (0.20) (0.20) (0.20) (0.20) (0.20) 143 NEW Product Bottom view 2 x M4 THD 19.9 (0.78) 19.9 (0.78) 19.3 (0.76) 8.89 11.43 11.43 8.89 (0.35) (0.45) (0.45) (0.35) 54.0 (2.13) Bottom view 31.6 (1.24) 15.9 (0.63) 2 x M4 THD (1.18) 15.24 12.70 12.70 15.24 30.0 (0.60) (0.50) (0.50) (0.60) 63.5 (2.50) 27.94 (1.10) 27.94 (1.10) Bottom view 12.70 12.70 (0.50) (0.50) 67.5 (2.66) 6 www.tracopower.com AC/DC Power Supplies Encapsulated Modules CB CB Schem Schemee CB CB TMM-C Series 24 to 60 W UL 60950-1 UL 60950-1 UL 60950-1 Scheme UL 60950-1 UL 508 UL 60601-1 ES 60601-1 UL 60950-1 UL 508 Scheme UL 60601-1 Fully encapsulated low profile plastic (chassis mount) –40°C start-up temperature IT and industrial safety according to IEC/EN/UL 60950-1 and UL 508 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition Ready to meet ErP directive <0.3W no load power consumption Protection class II prepared Power-good LED indicator Specifications Models Input voltage range 85–264 VAC, 47–63 Hz Order code* Output power Output 1 Output 2 85–370 VDC (derating below 110 VDC input) TMM 24105C 15 W 5.0 VDC 3000 mA Line regulation 60W models: 0.2% typ. TMM 24112C 12 VDC 2000 mA other models: 0.5% typ. TMM 24115C 24 W 15 VDC 1600 mA Load regulation Singel output: TMM 24124C 24 VDC 1000 mA – 24 & 60 W models: 0.5 % typ. TMM 24212C + 12 VDC 1000 mA – 12 VDC 1000 mA – 40 W models: 1.0% typ. TMM 24215C + 15 VDC 800 mA – 15 VDC 800 mA Dual output: – 24 W models: 2.5% typ. TMM 40105C 5.0 VDC 8000 mA – 40 W models: 2.0% typ. TMM 40112C 12 VDC 3300 mA TMM 40115C 40 W 15 VDC 2660 mA Ripple & noise 5.0 VDC models: 2% max. 5.1 VDC model: 3% max. TMM 40124C 24 VDC 1660 mA other models: 1.5% max. TMM 40212C + 12 VDC 1660 mA – 12 VDC 1660 mA EMI suppression EN 55011 class B, EN 55022 class B TMM 40215C + 15 VDC 1330 mA – 15 VDC 1330 mA EMC immunity EN 60601-1-2, EN 61000-6-2 TMM 60105C 5.1 VDC 10000 mA TMM 60112C 12 VDC 5000 mA Output current limitation >105% Inom. foldback, automatic recovery TMM 60115C 60 W 15 VDC 4000 mA Leakage current 80µA max. TMM 60124C 24 VDC 2500 mA Efficiency 83 % typ. TMM 60148C 48 VDC 1250 mA Operating temperature –40 ° C to +80 ° C above 60°C derating 3%/K Safety standards / UL 60950-1, IEC/EN 60950-1, UL 508 approvals IEC/EN 60601-1 3rd edition, 2 x MOPP ANSI/AAMI ES60601-1:2005(R)2012 Degree of protection class II prepared Casing plastic (UL 94V-0 rated) Option DIN-Rail clip Full datasheet www.tracopower.com/products/tmm24.pdf www.tracopower.com/products/tmm40.pdf www.tracopower.com/products/tmm60.pdf Dimensions TMM 24C: TMM 40C: TMM 60C: 63.8 (2.51) 34.1 (1.34) 54.0 (2.13) 23.3 (0.92) 50.0 (1.97) 6.9 5.0 11.8 (0.27) (0.20) (0.46) 67.8 (2.67) 38.0 (1.50) 46.0 (1.81) 4.0 5.0 11.8 (0.16) (0.20 (0.46) 50.0 (1.97) 8.9 5.0 11.8 (0.35) (0.20) (0.46) 37 46 5 37 46 5 4 x ø3.5 37 46 5 4 x ø3.5 4 x ø3.5 Top view Top view Top view 1 2 1 2 1 2 144 NEW Product 5.0 86.0 (3.39) (0.20) 96.0 (3.78) 10.0 76.0 (2.99) (0.39) 6.0 100.0 (3.94) (0.24) 112.0 (4.41) 10.0 92.0 (3.62) (0.39) 6.0 100.0 (3.94) (0.24) 112.0 (4.41) 10.0 92.0 (3.62) (0.39) www.tracopower.com Encapsulated Modules AC/DC Power Supplies CB TML-100C Series 100 W UL 60950-1 Scheme Very compact power modules with a low profile and screw terminal connection Active PFC, power factor >0.95 (230VAC), >0.99 (115 VAC) High efficiency up to 93% Remote On/Off input Power-good LED indicator Specifications Models Input voltage range 85–264 VAC, 47–63 Hz Order code* Output power Output 1 Output 2 85–370 VDC (derating below 110 VDC input) TML 100-112C 85 W 12 VDC 7000 mA Line regulation 1.0% max TML 100-115C 15 VDC 5660 mA Load regulation 1.0% max. TML 100-124C 100 W 24 VDC 4200 mA Ripple & noise 12 VDC model: 120 mV max. TML 100-148C 48 VDC 2100 mA 15 VDC model: 150 mV max. 24 VDC model: 200 mV max. 48 VDC model: 240 mV max. EMC immunity EN 61000-6-2 Output current limitation >105% Inom. foldback, automatic recovery Efficiency 91 % typ. Operating temperature –25 ° C to +70 ° C above 50°C derating of 2.0%/K Safety standards / IEC 60950-1 2nd ed +Am1 approvals UL 60950-1 2nd ed +Am1 EN 60950-1:2006/A11:2009/A1:2010/A12:2011 Degree of protection class I and class II prepared Casing plastic (UL 94V-0 rated) Full datasheet www.tracopower.com/products/tml100c.pdf 4 1 5 2 Top view 6 3 7 8 140.0 (5.6) () = Inches 145 NEW Product 62.0 (2.48) 36.6 (1.46) www.tracopower.com AC/DC Power Supplies Encapsulated Modules CB TIW Series 4 to 24 W UL 60950-1 Scheme Easy installation into standard flush boxes Dust and waterproof to IP 67 Meets ERP directive (green mode), <0.3 W no load power consumption, high efficiency across full load range Regulated output voltage Safety approval to EN 60950-1 and EN 60335-1 Protection class II Short circuit and overload protection Specifications Specifications Models Models Input voltage range 93–264 VAC, 47–63 Hz Order code Output power Output voltage Output current max. Line regulation 1.0 % max. TIW 06-103 4 W 3.3 VDC 1200 mA Load regulation 2.0 % TIW 06-105 5 W 5.0 VDC 1000 mA Ripple & noise <300 mVp-p for 3.3 - 6.0 VDC models TIW 06-106 6 W 6.0 VDC 1000 mA (20 MHz BW) <500 mVp-p for other models TIW 12-112 12 W 12 VDC 1000 mA EMI suppression EN 55022 class B TIW 12-115 12 W 15 VDC 800 mA EMC immunity EN 61000-6-2 TIW 12-124 12 W 24 VDC 500 mA Output current limitation >2.5 A for 3.3 - 6.0 VDC models TIW 24-112 24 W 12 VDC 2000 mA >3.5 A for other models TIW 24-124 24 W 24 VDC 1000 mA Efficiency 81 % typ. Operating temperature –25 ° C to +50 ° C Safety standards / IEC/EN 60950-1, EN 50178, EN 60335-1, approvals CB-report (UL approvals pending) Degree of protection class II as per IEC/EN 61140 Casing IP 67, plastic (UL 94V-0 rated) Full datasheet www.tracopower.com/products/tiw.pdf Dimensions TIW 24 Models: TIW 06 & 12 Models: 3.2 3.2 Flat 2-core cable 16 -18AWG. Outer insulation 3.5mm x 7.0mm typ. 3.2 Flat 2-core cable 16 -18AWG. 3.2 Outer insulation 3.5mm x 7.0mm typ. 12.5 12.5 48.0 15.4 Bottm View 15.4 56.0 NL Bottm View Input NL 4.0 Input 4.5 Output Output - - + + Ø8 1. Ø8 1. 4.0 Ø8 1. 23.6 Ø8 1. 20AWG/BLACK Side View 4.5 20AWG/RED 20AWG/BLACK 32.0 20AWG/RED 5.7 Tolerances: ±0.2mm Side View Top Side 5.7 Tolerances: ±0.2mm Top Side (Mounted in standard flush box) () = Inches 146 NEW Models R 27.5 R 31.5 55.0 63.0 40mm 200mm (+20/-0) 8mm 5.0±2 570mm (+30/-0) 20.5 20.5 52.0 200mm 8mm 5.0±2 600mm 23.5 23.5 52.0 www.tracopower.com Metal Enclosure AC/DC Power Supplies C CBB CB TPP 40 Series 40 W Schem Schemee UL ES 60601-1 60950-1 UL 60950-1 UL 508 Scheme High power density encased 40 W power supply 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition Ready to meet ErP directive, < 0.3 W no load power consumption Highest efficiency 91 to 92% across 10% – 100% load range Protection class II prepared Specifications Models Order code Output power Output voltage Output current Input voltage range 85-264VAC (47-63Hz) / 120-370VDC max. max. Line regulation 0.2 % max. TPP 40-105 5 VDC 8.0 A Load regulation 0.7 % max. TPP 40-112 12 VDC 3.34 A Output voltage approx. +10 % of Vout nom. by internal potentiometer TPP 40-115 15 VDC 2.67 A adjustment TPP 40-124 24 VDC 1.67 A Ripple & noise 75 – 100 mVpk-pk typ. depending on model TPP 40-221 40 W +12 / +5 VDC 3.34 / 6.0 A (20 MHz BW) with external capacitor TPP 40-231 +15 / +5 VDC 2.67 / 6.0 A EMI emission EN 55011/22 class B, harmonic current EN 61000-3-2 TPP 40-251 +24 / +5 VDC 1.67 / 6.0 A EMC immunity EN61000-6-1, EN 60601-1-2 TPP 40-321M2 +12 / +5 / -12 VDC 3.34 / 6.0 / 0.5 A TPP 40-331M3 +15 / +5 / -15 VDC 2.67 / 6.0 / 0.5 A Output current limitation >150% Inom. continuous, automatic recovery TPP 40-3512 +24 / +5 / +12 VDC 1.67 / 6.0 / 0.5 A Efficiency 91 % typ. Operating temperature –40 ° C to +73 ° C (convection cooling) with derating up to +80°C Leakage current 75µA max. at 264 VAC Altitude Operating up to 5000m altitude Safety standards / IEC/EN 60601-1 3rd edition, CB-report approvals ANSI/AAMI ES60601-1:2005(R)2012 Degree of protection class II prepared Casing Encased with screw terminal Full datasheet www.tracopower.com/products/tpp40.pdf Dimensions Sinle output: Multi output: () = Inches 147 NEW Product www.tracopower.com AC/DC Power Supplies Metal Enclosure CB CB CB TPP 65 Series 65 W Schem Schemee UL 60950-1 UL 60950-1 ES 60601-1 UL 60950-1 UL 508 Scheme High power density encased 65 W power supply 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition Ready to meet ErP directive, < 0.3 W no load power consumption Highest efficiency 91 to 92% across 10% – 100% load range Protection class II prepared Specifications Models Order code Output power Output voltage Output current Input voltage range 85-264VAC (47-63Hz) / 120-370VDC max. max. Line regulation 0.2 % max. TPP 65-105 5 VDC 10.0 A Load regulation 0.7 % max. TPP 65-112 12 VDC 5.42 A Output voltage approx. +10 % of Vout nom. by internal potentiometer TPP 65-115 15 VDC 4.34 A adjustment TPP 65-124 24 VDC 2.71 A Ripple & noise 75 – 100 mVpk-pk typ. depending on model TPP 65-221 65 W +12 / +5 VDC 5.42 / 8.0 A (20 MHz BW) with external capacitor TPP 65-231 +15 / +5 VDC 4.34 / 8.0 A EMI emission EN 55011/22 class B, harmonic current EN 61000-3-2 TPP 65-251 +24 / +5 VDC 2.71 / 8.0 A EMC immunity EN61000-6-1, EN60601-1-2 TPP 65-321M2 +12 / +5 / -12 VDC 5.42 / 8.0 / 0.6 A TPP 65-331M3 +15 / +5 / -15 VDC 4.34 / 8.0 / 0.6 A Output current limitation >150% Inom. continuous, automatic recovery TPP 65-3512 +24 / +5 / +12 VDC 2.71 / 8.0 / 0.6 A Efficiency 90 % typ. Operating temperature –40 ° C to +60 ° C (convection cooling) with derating up to +80°C Leakage current 75µA max. at 264 VAC Altitude Operating up to 5000m altitude Safety standards / IEC/EN 60950-1, CB-report approvals IEC/EN 60601-1 3rd edition, ANSI/AAMI ES60601-1:2005(R)2012 Degree of protection class II prepared Casing Encased with screw terminal Full datasheet www.tracopower.com/products/tpp65.pdf Dimensions Sinle output: Multi output: () = Inches 148 NEW Product www.tracopower.com Metal Enclosure AC/DC Power Supplies C CBB CB TPP 100 Series 100 W Schem Schemee UL ES 60601-1 60950-1 UL 60950-1 UL 508 Scheme Highest power density encased 100 W power supply 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition Ready to meet ErP directive, < 0.3 W no load power consumption Highest efficiency 91 to 92% across 10% – 100% load range Active power factor correction (>95) Protection class II prepared Specifications Models Order code Output power Output voltage Output current Input voltage range 85-264VAC (47-63Hz) / 120-370VDC max. max. Line regulation 0.2 % max. TPP 100-112 12 VDC 8.34 A Load regulation 0.5 % max. TPP 100-115 15 VDC 6.67 A Output voltage approx. +10 % of Vout nom. by internal potentiometer TPP 100-124 100 W 24 VDC 4.17 A adjustment TPP 100-136 36 VDC 2.78 A Ripple & noise 120 – 340 mVpk-pk depending on model TPP 100-148 48 VDC 2.09 A (20 MHz BW) with external capacitor Options on demand: EMI emission EN 55011/22 class B, harmonic current EN 61000-3-2 - open frame EMC immunity EN61000-6-1, EN 60601-1-2 - pin connector - DIN-rail clip Output current limitation >150% Inom. continuous, automatic recovery Efficiency 91 % typ. Operating temperature –25 ° C to +80 ° C (convection cooling) derating 2.33 %/K above 50 ° C Altitude Operating up to 5000m altitude Safety standards / UL 60950-1, IEC/EN 60950-1, approvals IEC/EN 60601-1 3rd edition, ANSI/AAMI ES60601-1:2005(R)2012 Degree of protection class II prepared Casing Encased with screw terminal Full datasheet www.tracopower.com/products/tpp100.pdf Dimensions () = Inches 149 NEW Product www.tracopower.com AC/DC Power Supplies Metal Enclosure CB CB CB TPP 150 Series 150 W Schem Schemee UL 60950-1 UL 60950-1 ES 60601-1 UL 60950-1 UL 508 Scheme Highest power density encased 150 W power supply 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition Ready to meet ErP directive, < 0.3 W no load power consumption Highest efficiency 91 to 92% across 10% – 100% load range Active power factor correction (>95) Protection class II prepared Specifications Models Order code Output power Output voltage Output current Input voltage range 85-264VAC (47-63Hz) / 120-370VDC max. max. Line regulation 0.2 % max. TPP 150-112 12 VDC 12.5 A Load regulation 0.5 % max. TPP 150-115 15 VDC 10.0 A Output voltage approx. +10 % of Vout nom. by internal potentiometer TPP 150-124 150 W 24 VDC 6.25 A adjustment TPP 150-136 36 VDC 4.17 A Ripple & noise 120 – 480 mVpk-pk depending on model TPP 150-148 48 VDC 3.13 A (20 MHz BW) with external capacitor Options on demand: EMI emission EN 55011/22 class B, harmonic current EN 61000-3-2 - open frame EMC immunity EN61000-6-1, EN 60601-1-2 - pin connector - DIN-rail clip Output current limitation >150% Inom. continuous, automatic recovery Efficiency 91 % typ. Operating temperature –25 ° C to +80 ° C derating 2.33 %/K above 50 ° C Altitude Operating up to 5000m altitude Safety standards / UL 60950-1, IEC/EN 60950-1, approvals IEC/EN 60601-1 3rd edition, ANSI/AAMI ES60601-1:2005(R)2012 Degree of protection class II prepared Casing Encased with screw terminal Full datasheet www.tracopower.com/products/tpp150.pdf Dimensions () = Inches 150 NEW Product www.tracopower.com Metal Enclosure AC/DC Power Supplies CB TXM Series 15 to 320 W Scheme UL 60950-1 Very compact enclosed power supplies Cost optimized design Low no load power consumption <0.5 W up to 75 W units Screw terminal block No internal fan up to 150 W models Universal input 88–264 VAC Adjustable output voltage Short circuit and overvoltage protection PCB solder side conformal coated Specifications Models Order code Output power Output voltage Output current Input voltage range 88–264 VAC, 47–63 Hz max. max. Line regulation 0.5 % TXM 015-103 13 W 3.3 VDC 4.0 A TXM 015-105 5.0 VDC 3.0 A Load regulation 2.0 % TXM 015-112 15 W 12 VDC 1.3 A Output voltage ±10 % of Vout nom. with potentiometer TXM 015-115 15 VDC 1.0 A adjustment: TXM 015-124 24 VDC 0.7 A Ripple & noise <1 % of Vout nom. TXM 025-103 20 W 3.3 VDC 5.0 A TXM 025-105 5.0 VDC 5.0 A EMI suppression EN 55011, class B, EN 55022, class B and FCC, part 15, TXM 025-112 25 W 12 VDC 2.1 A level B, EN 61000-3-2 TXM 025-115 15 VDC 1.6 A EMC immunity EN 61000-6-1 TXM 025-124 24 VDC 1.1 A 30 W TXM 035-105 5.0 VDC 6.0 A Output current limitation >105 % of Iout max. TXM 035-112 12 VDC 3.0 A Overvoltage protection >110 % of Vout nom. 35 W TXM 035-115 15 VDC 2.4 A Efficiency 85 % typ. TXM 035-124 24 VDC 1.5 A TXM 035-148 48 VDC 0.75 A Operating temperature –20 ° C to +70 ° C TXM 050-105 40 W 5.0 VDC 8.0 A above 45 °C derating 2.5 %/K TXM 050-112 12 VDC 4.2 A Safety standards / cUL/UL 60950-1, IEC/EN 60950-1 TXM 050-115 50 W 15 VDC 3.4 A approvals TXM 050-124 24 VDC 2.2 A TXM 050-148 48 VDC 1.1 A Connection screw terminal block TXM 075-105 60 W 5.0 VDC 12.0 A Casing Metal enclosure, TXM 075-112 12 VDC 6.0 A 240 & 320 Watt models with internal fan TXM 075-115 75 W 15 VDC 5.0 A TXM 075-124 24 VDC 3.2 A Full datasheet www.tracopower.com/products/txm.pdf TXM 075-148 48 VDC 1.6 A TXM 100-105 5.0 VDC 20.0 A Dimensions TXM 100-112 12 VDC 8.5 A Type Length l Width w Heigth h 100 W TXM 100-115 15 VDC 6.7 A TXM 100-124 24 VDC 4.2 A TXM 015 79 (3.11) 51 (2.01) 29 (1.14) TXM 100-148 48 VDC 2.15 A TXM 025 79 (3.11) 51 (2.01) 29 (1.14) TXM 150-112 12 VDC 12.5 A TXM 035 102 (4.02) 64 (2.52) 33 (1.30) TXM 150-124 150 W 24 VDC 6.3 A TXM 050 99 (3.90) 82 (3.23) 35 (1.38) TXM 150-148 48 VDC 3.2 A TXM 240-112 12 VDC 16.7 A TXM 075 129 (5.08) 99 (3.90) 38 (1.50) TXM 240-124 240 W 24 VDC 8.4 A TXM 100 179 (7.05) 99 (3.90) 50 (1.97) TXM 240-148 48 VDC 4.2 A TXM 150 179 (7.05) 99 (3.90) 50 (1.97) TXM 320-112 12 VDC 25.0 A TXM 240 199 (7.83) 99 (3.90) 50 (1.97) TXM 320-124 320 W 24 VDC 13.0 A TXM 320 199 (7.83) 99 (3.90) 50 (1.97) TXM 320-136 36 VDC 8.8 A TXM 320-148 48 VDC 6.7 A () = Inch TXM 035 TXM 015 TXM 050 TXM 025 TXM 075 TXM 100 TXM 240 TXM 150 TXM 320 14 l l 12 for TXM 015 and TXM 025 151 w h w h www.tracopower.com AC/DC Power Supplies Metal Enclosure CB TXL Series 15 to 1000 W Scheme UL 60950-1 Metal casing with screw terminal block Single-, dual- and triple output models Multi output models with isolated outputs Universal input 85–264 VAC Adjustable output voltage Short circuit and overvoltage protection Specifications Specifications Models Models Order code Output power Output voltage Output current Case max. nom. max. Input voltage range 85–264 VAC, 50/60 Hz TXL 015-3.3S 10 W 3.3 VDC 3.0 A B 120–370 VDC TXL 015-05S 5 VDC 3.0 A B TXL 015-12S 12 VDC 1.3 A B Line regulation 1.0 % TXL 015-15S 15 W 15 VDC 1.0 A B Load regulation 2.0 % TXL 015-24S 24 VDC 0.63 A B TXL 015-48S 48 VDC 0.32 A B Output voltage ±10 % of Vout nom. with potentiometer TXL 025-3.3S 20 W 3.3 VDC 6.0 A C adjustment: TXL 025-05S 5 VDC 5.0 A C TXL 025-12S 12 VDC 2.1 A C Ripple & noise <1 % of Vout nom. TXL 025-15S 25 W 15 VDC 1.7 A C EMI suppression EN 55011, class B, EN 55022, class B and FCC, part 15, TXL 025-24S 24 VDC 1.1 A C TXL 025-48S 48 VDC 0.57 A C level B, EN 61000-3-2 TXL 035-3.3S 30 W 3.3 VDC 9.0 A D EMC immunity EN 61000-6-1 TXL 035-05S 5 VDC 7.0 A D TXL 035-12S 12 VDC 3.0 A D Output current limitation at 105–150 % of Iout max. (foldback, automatic recovery) TXL 035-15S 35 W 15 VDC 2.4 A D Overvoltage protection at 115–140 % of Vout nom. TXL 035-24S 24 VDC 1.5 A D TXL 035-48S 48 VDC 0.8 A D Efficiency 80 % typ. TXL 050-05S 50 W 5 VDC 10.0 A D TXL 060-3.3S 50 W 3.3 VDC 15.0 A E Operating temperature –10 ° C to +70 ° C TXL 060-05S 5 VDC 12.0 A E above 45 ° C derating 2 %/K TXL 060-12S 60 W 12 VDC 5.0 A D TXL 060-15S 15 VDC 4.0 A D Safety standards / cUL/UL 60950-1, EN 60950-1, CB-report TXL 060-24S 24 VDC 2.5 A D approvals TXL 070-12S 12 VDC 6.0 A E Connection screw terminal block TXL 070-15S 70 W 15 VDC 4.8 A E TXL 070-24S 24 VDC 3.0 A E Casing aluminium / steel, 230 -1000 W models with internal fan TXL 070-48S 48 VDC 1.5 A E TXL 100-05S 5 VDC 20.0 A J Full datasheet www.tracopower.com/products/txl.pdf TXL 100-12S 12 VDC 8.5 A J TXL 100-15S 100 W 15 VDC 6.8 A J Dimensions TXL 100-24S 24 VDC 4.5 A J Case TXL 100-48S 48 VDC 2.1 A J Length l Width w Height h Type TXL 150-05S 5 VDC 30.0 A L TXL 150-12S 150 W 12 VDC 12.5 A L B 62 (2.48) 51 (2.01) 28 (1.10) TXL 150-24S 24 VDC 6.3 A L C 79 (3.11) 51 (2.01) 29 (1.14) TXL 150-48S 48 VDC 3.2 A L TXL 230-12S 12 VDC 19.2 A N D 99 (3.90) 82 (3.23) 35 (1.38) TXL 230-24S 230 W 24 VDC 9.6 A N E 160 (6.30) 95 (3.74) 38 (1.50) TXL 230-48S 48 VDC 4.8 A N TXL 350-24S 350 W 24 VDC 14.7 A O J 198 (7.80) 95 (3.74) 38 (1.50) TXL 350-48S 48 VDC 7.5 A O L 198 (7.80) 99 (3.90) 50 (1.97) TXL 750-24S 750 W 24 VDC 31.3 A P N 198 (7.80) 99 (3.90) 45 (1.77) TXL 750-48S 48 VDC 15.8 A P TXL 1000-24S 1000 W 24 VDC 40 A Q O 212 (8.35) 115 (4.53) 50 (1.97) TXL 1000-48S 48 VDC 21 A Q P 275 (10.83) 125 (4.92) 63 (2.48) Q 295 (11.61) 127 (5.00) 40 (1.57) () = Inch Multi Output Models Order code Output Output 1* Output 2* Output 3* Case power max. () = Inch TXL 035-0512D +5 VDC / 4.0 A +12 VDC / 2.5 A D TXL 035-0524D 35 W +5 VDC / 4.0 A +24 VDC / 1.3 A D TXL 035-1212D +12 VDC / 1.5 A –12 VDC / 1.5 A D TXL 035-1515D +15 VDC / 1.3 A –15 VDC / 1.3 A D TXL 060-0512DI 5 VDC / 8.0 A 12 VDC / 4.0 A E TXL 060-0524DI 5 VDC / 8.0 A 24 VDC / 2.2 A E TXL 060-0521TI 60 W 5 VDC / 8.0 A 12 VDC / 3.5 A 5 VDC / 1.0 A E TXL 060-0522TI 5 VDC / 7.0 A 12 VDC / 3.5 A 12 VDC / 1.0 A E TXL 060-0533TI 5 VDC / 7.0 A 15 VDC / 3.0 A 15 VDC / 1.0 A E TXL 060-0534TI 5 VDC / 6.0 A 12 VDC / 1.5 A 24 VDC / 1.2 A E TXL 100-0512DI 5 VDC / 12 A 12 VDC / 6.0 A J TXL 100-0524DI 5 VDC / 10 A 24 VDC / 4.0 A J TXL 100-0521TI 100 W 5 VDC / 12 A 12 VDC / 5.0 A 5 VDC / 1.5 A J TXL 100-0522TI 5 VDC / 12 A 12 VDC / 5.0 A 12 VDC / 1.5 A J TXL 100-0533TI 5 VDC / 12 A 15 VDC / 3.0 A 15 VDC / 1.5 A J TXL 100-0534TI 5 VDC / 12 A 12 VDC / 3.0 A 24 VDC / 2.0 A J 60 & 100 Watt models with fully isolated outputs 12 l *Total power not to exceed specified output power 152 h w www.tracopower.com Metal Enclosure AC/DC Power Supplies CB TXH Series 120 to 480 W Scheme UL 60950-1 Compact U-bracket and enclosed power supplies Screw terminal block Very high efficiency up to 93% No internal fan for 120 W & 240 W models Universal input 90–264 VAC Short circuit and overvoltage protection Specifications Models Order code Output power Output voltage Output current Input voltage range 90–264 VAC, 50/60 Hz max. max. 120–370 VDC TXH 120-112 12 VDC 10 A Line regulation 1.0 % TXH 120-124 24 VDC 5 A 120 W Load regulation 1.0 % TXH 120-148 48 VDC 2.5 A Output voltage ±10 % of Vout nom. with potentiometer TXH 240-112 12 VDC 20 A adjustment: TXH 360 and TXH 480 models only TXH 240-124 24 VDC 10 A 240 W Ripple & noise <1 % of Vout nom. TXH 240-148 48 VDC 5 A EMI suppression EN 55011, class B, EN 55022, class B and FCC, part 15, TXH 360-112 12 VDC 30 A level B, EN 61000-3-2 TXH 360-124 24 VDC 15 A 360 W EMC immunity EN 61000-6-1 TXH 360-148 48 VDC 7.5 A Output current limitation >110 % of Iout max. TXH 480-112* 12 VDC 40 A Overvoltage protection >110 % of Vout nom. TXH 480-124* 24 VDC 20 A 480 W TXH 480-148* 48 VDC 10 A Efficiency 90 % typ. Operating temperature –10 ° C to +70 ° C * Standby / auxillary output 5 V / 600 mA above 50 °C derating 2.5 %/K Cover Safety standards / cUL/UL 60950-1, EN 60950-1, CB-report TXH 120-COV Cover for TXH 120 models approvals TXH 240-COV Cover for TXH 240 models Connection screw terminal block TXH 480: connector for control functions (remote On/Off, sense line, standby / auxillary output) Casing 120 & 240 W models: U-bracket (optional cover) 360 & 480 W models: Metal enclosure Full datasheet www.tracopower.com/products/txh.pdf Dimensions 120 W & 240 W models: 360 & 480 W models: TXH 360: 197.7 (7.78) TXH 480: 202.8 (7.98) TXH 120: 138 (5.43) TXH 240: 177 (6.97) air flow AC in AC in () = Inches 153 TXH 120: 38 (1.50) TXH 120: 82 (3.23) TXH 240: 35 (1.38) TXH 240: 106 (4.17) TXH 360: 42 (1.65) TXH 360: 81.3 (3.20) TXH 480: 45 (1.77) TXH 480: 106.5 (4.19) www.tracopower.com AC/DC Power Supplies Metal Enclosure CB TXH-600 Series 600 W Scheme UL 60950-1 Universal input: 90–264 VAC or 120–370 VDC Active power factor correction (>0.95) Very high efficiency up to 93% Current share function for up to 3 units in parallel Adjustable output voltage Protection against over-voltage, overtemperature, overload and short circuit Rear side IEC-C13 line socket, including mains switch and fuse Specifications Models Order code Output power Output voltage Output current Input voltage range 90–264 VAC, 50/60 Hz max. max. 120–370 VDC TXH 600-112 12 VDC 45 A Line regulation 1.0 % max. TXH 600-124 24 VDC 25 A 600 W Load regulation 1.0 % max. TXH 600-148 48 VDC 12.5 A Output voltage ±5 % of Vout nom. with potentiometer TXH 600-154 54 VDC 11.1 A adjustment: Ripple & noise <1 % of Vout nom. [mVpk-pk] EMI suppression EN 55011, class B, EN 55022, class B and FCC, part 15, level B, EN 61000-3-2 EMC immunity EN 61000-6-1 Output current limitation auto recovery Overvoltage protection >120 % of Vout nom. Efficiency 92 % typ. Operating temperature –25 ° C to +65 ° C above 50 °C derating 4 %/K Safety standards / cUL/UL 60950-1, EN 60950-1, CB-report approvals Connection screw terminal block Casing Metal enclosure Full datasheet www.tracopower.com/products/txh600.pdf Dimensions () = Inches 154 NEW Product www.tracopower.com Metal Enclosure AC/DC Power Supplies CB IP67 TEX Series 120 W Scheme UL 508 Sealed, rugged die-cast aluminium casing Dust- and water resistant to IP67 & NEMA 4X Wide operating temperature range –40 °C to +85 °C Easy connection via waterproof plugs Universal input voltage 85–264 VAC, 85-375 VDC Adjustable output voltage Short circuit and overload protection Certificate for test and measurements EN 61010 3rd edition UL 508 listed Class I, zone 2 approval incl. ATEX certification for hazardous locations (Class I, Div. 2) Specifications Models Input voltage range 85–264 VAC, 47–63 Hz Order code Output power Output voltage Output current 85–375 VDC max. Outpu regulation 2.5 % max. TEX 120-112 96 W 12 VDC 8 A TEX 120-124 120 W 24 VDC 5 A Output voltage 12 V model: 12 - 15 VDC, 24 V model: 24 - 28 VDC, with adjustment internal potentiometer Ripple & noise <50 mVpk-pk (20 MHz BW) Accessories TEX-P11 AC input connector EMI suppression EN 55022 class B, TEX-P21 DC output connector harmonic current EN 61000-3-2, class A TEX-C11 Input cable assembly 2m (for UL508 compliance) EMC immunity EN61000-6-2, SEMI F47 TEX-C21 Output cable assembly 2m Output current limitation >125% Inom. Efficiency 90 % typ. Operating temperature –40 ° C to +85 ° C (convection cooling) above 60 ° C derating 2.0 %/K Safety standards / UL 508, UL 1604, EN 61010 3rd edition , approvals IEC/EN 60950-1 (CB-Report), EN 50178, EN 60204, EN 61558-2-8, IEC/EN 60079-15 (class I, div.2), UL 60079-15, ANSI/ISA 12.12.01 (class I, div. 2), EN 50021, ATEX 94/9/EC Degree of protection safety class I, (IEC 536) Case protection IP 67 (IEC 60529), NEMA 4X rated, UL 50 Shock & vibration meets IEC 60068-2-6, IEC 60068-2-27 Humidity up to 100 % rel. H with condensation Full datasheet www.tracopower.com/products/tex120.pdf Dimensions Mating Connectors (not included in shipment) Input Output AC Input: Binder 3-pin female circular plug 693 series: 99-4222-14-04 DC Output: Binder 7-pin male circular plug 693 series: 99-4225-160-07 units are supplied with sealing connector caps 5 6 4 7 2 1 174 (6.85) 3 164 (6.46) 1 2 154 (6.06) INPUT OUTPUT 1 L 1 - 4 + 2 N 2 - 5 + PE 3 - 6 + 7 case () = Inches 155 4 x ø 4.8 (0.19) 93 (3.66) 83 (3.27) 56 (2.20) 7.0 (0.28) www.tracopower.com AC/DC Power Supplies DIN-Rail Mount CB TBL Series 15 to 150 W Scheme UL508 UL1310 UL60950-1 Low profile plastic case For building- and industrial automation applications Model with battery controller for UPS system Fits into flat control panels Meets NEC class II (limited power source) Safety class II Universal input voltage 85–264 VAC Adjustable output voltage Short circuit and overload protection UL 508 listed Specifications Specifications Models Models Order code Output power Output voltage Output current Input voltage range 85–264 VAC, 47-63 Hz max. max. TBL 150 models: 85–132 / 187–264 VAC (autorange) TBL 015-105* 5.0 VDC 2.4 A Output regulation 1.0 % max. TBL 015-112* 12 VDC 1.25 A 15 W Output voltage 5 V models: 5.0 - 5.2 VDC TBL 015-124* 24 VDC 0.63 A adjustment range 12 V models: 12.0 - 16.0 VDC TBL 030-112* 12 VDC 2.5 A 30 W 24 V models: 24.0 - 28.0 VDC TBL 030-124* 24 VDC 1.25 A Ripple & noise <100 mVpk-pk (20 MHz BW) TBL 060-112* 12 VDC 4.5 A 60 W EMI emission EN 55011/22, class B, EN61000-6-3 TBL 060-124* 24 VDC 2.5 A EMC immunity EN 61000-6-2 TBL 090-112 90 W 12 VDC 6.0 A Output current limitation >105% of Iout max. TBL 090-124* 24 VDC 3.75 A Over voltage protection at 140 % of Vout nom. TBL 150-112 12 VDC 10 A 120 W Efficiency 80 % typ. TBL 150-124 150 W 24 VDC 6.25 A Operating temperature –25 ° C to +70 ° C * Models meet NEC class II (limited power source) acc. UL 1310 above 60 ° C derating 2 .5%/K Model with Battery Controller (For UPS-System) Safety standards / UL 1310, IEC/EN 60950-1, CB-Report, cUL/UL 508 listed, Order code Battery Max. Battery Output Power approvals EN 50178, EN 60204, EN 61558-2-8 voltage load current voltage adj. max. Connection screw terminals TBL 060-124BC 24 VDC 2 A 26-29.5 VDC 60 W Casing plastic (UL 94V-0 rated) Mounting snap-on mounting on 35 mm DIN-rail or wall mount with included brackets Full datasheet www.tracopower.com/products/tbl.pdf For details see datasheet: www.tracopower.com/products/tbl-bc.pdf Dimensions Type Width (w) 43.5 (1.71) TBL 015 26.3 (1.03) 27.5 (1.08) TBL 030 52.5 (2.07) Vadj TBL 060 70 (2.78) TBL 090 105 (4.13) TBL 150 175 (6.89) TBL 060-124BC 175 (6.89) 54.5 (2.15) W () = Inches 156 69.4 (2.73) 44.8 (1.76) 89.3 (3.52) www.tracopower.com DIN-Rail Mount AC/DC Power Supplies TCL / TCL-DC Series 24 to 240 W UL 60950UL 508C UL 60950-1 For industrial-, office- and residential environments Available with detachable screw terminals or spring clamps Standard models with 5, 12, 24 and 48 VDC output Models with DC input: 9.5-18 VDC and 18-75 VDC Universal input 85–264 VAC Worldwide safety approval package Adjustable output voltage Power Good signal Parallel and redundant operation Specifications Models Order code Output power Output voltage Output current Input voltage range 85–264 VAC, 47-63 Hz, 85–375 VDC max. (adjustable output) max. TCL 240 models: 85–132 / 187–264 VAC (autorange) TCL 024-105 5.1 VDC 4.0 A DC Input models: 18-75 VDC TCL 024-112 12 VDC 2.0 A 24 Watt TCL 012-124 DC: 9.5-18 VDC TCL 024-124 (C) 24 VDC 1.0 A Output regulation 1.25 % max. TCL 060-112 (C) 12 VDC 4.0 A Ripple & noise <50 mVpk-pk (20 MHz BW) TCL 060-124 (C) 24 VDC 2.5 A 60 Watt EMI emission EN 55011, class B, EN 55022, class B, EN61000-6-3 TCL 060-148 (C) 48 VDC 1.25 A EMC immunity EN 61000-6-2 (industrial environment), SEMI F47 TCL 120-112 (C) 12 VDC 8.0 A 120 Watt Output current limitation at 130 % of Iout max. TCL 120-124 (C) 24 VDC 5.0 A Over voltage protection at 140 % of Vout nom. TCL 240-124 24 VDC 10.0 A 240 Watt Efficiency 90 % typ. without suffix: detachable screw terminal block with suffix C: spring clamps DC-OK Signal open collector / max. 30 mA Operating temperature –10 ° C to +70 ° C , –25 ° C to +70 ° C for DC input models Redundancy Module above 50 ° C derating 1.7 %/K 2 Inputs Output voltage Order code Output current Safety standards / cUL/UL 60950-1, UL 508C listed, IEC/EN 60950-1, CB-Report max. approvals EN 50178, EN 60204, EN 61558-2-8 TCL-REM240 5 – 60 VDC Vin - 0.9 VDC 8.0 A Connection detachable screw terminals or spring clamp terminals 144 W max./input Casing plastic (UL 94V-0 rated) Mounting snap-on mounting on 35 mm DIN-rail or chassis mounting Models with DC Input with mounting bracket (included) Order code Input voltage Output voltage Output current range (adjustable output) max. Options output current characteristics set for battery charging TCL 012-124DC 24 VDC 1.0 A 9.5–18 VDC applications TCL 024-105DC 5 VDC 5.0 A Full datasheet AC/DC: www.tracopower.com/products/tcl.pdf TCL 024-112DC 12 VDC 2.0 A 18–75 VDC DC/DC: www.tracopower.com/products/tcl-dc.pdf TCL 024-124DC 24 VDC 1.0 A TCL 060-112DC 12 VDC 5.0 A 18–75 VDC TCL 060-124DC 24 VDC 2.5 A Dimensions Type Width w Heigth h Depth d TCL 012 27 (1.06) 75 (2.95) 100 (3.94) TCL 024 & REM 27 (1.06) 75 (2.95) 100 (3.94) TCL 060 45 (1.77) 75 (2.95) 100 (3.94) TCL 120 85 (3.35) 75 (2.95) 100 (3.94) TCL 240 85 (3.35) 110 (4.33) 125 (4.92) d w () = Inches 157 h www.tracopower.com AC/DC Power Supplies DIN-Rail Mount CB TPC Series 30 to 120 W Scheme UL 60950-1 UL 508 Slim plastic casing For industrial-, office- and residential environments Meets ErP directive (green mode), <0.3 W no load power consumption, high efficiency across full load range Universal input 85–264 VAC Worldwide safety approval package Adjustable output voltage +20% of nominal Power Good signal Remote On/Off Parallel and redundant operation Specifications Models Order code Output power Output voltag Output current Input voltage range 85–264 VAC, 47-63 Hz universal input max. nominal adjustable range max. 90–375 VDC TPC 030-105 20 W 5 VDC 5.0-6.0 VDC 4.0 A Line regulation 0.5% max. TPC 030-112 30 W 12 VDC 12-15 VDC 2.2 A Load regulation 0.5% max. TPC 030-124 30 W 24 VDC 24-28.8 VDC 1.25 A Ripple & noise <80 mVpk-pk (20 MHz BW) TPC 030-148 30 W 48 VDC 48-56 VDC 0.6 A EMI emission EN61000-6-3 (residential environment) TPC 055-112 42 W 12 VDC 12-15 VDC 3.5 A EMC immunity EN 61000-6-2 (industrial environment), SEMI F47 TPC 055-124 55 W 24 VDC 24-28.8 VDC 2.3 A Output current limitation 100 - 200 % of Iout max. (constant current) TPC 055-148 55 W 48 VDC 48-56 VDC 1.15 A TPC 080-112 72 W 12 VDC 12-15 VDC 6.0 A Overvoltage protection at 160% of Vout nom. TPC 080-124 80 W 24 VDC 24-28.8 VDC 3.3 A Efficiency 87% average at power consumption 25-100%. TPC 080-148 80 W 48 VDC 48-56 VDC 1.7 A - standby power loss: TPC 030: <0.3W, other models <0.5W TPC 120-112 96 W 12 VDC 12-15 VDC 8.0 A Operating temperature –25°C to +70°C TPC 120-124 120 W 24 VDC 24-28.8 VDC 5.0 A above 50°C derating 2.5% / K TPC 120-148 120 W 48 VDC 48-56 VDC 2.5 A Safety standard IEC/EN 60950-1, EN 50178, EN 60204, UL 508, UL 60950-1 Connection screw terminals Redundancy Module Casing plastic Mounting snap-on mounting on 35 mm DIN-rail or chassis mounting Order code 2 Inputs Output voltage Output current max. with mounting bracket (included) TPC-REM240-24 24 VDC 24 - 27 VDC 10.0 A Remote On/Off shutdown input for standby operation 5 A max / input adjustable - power loss: TPC 030: <0.3 W, other models <0.5 W Full datasheet www.tracopower.com/products/tpc.pdf - Active current sharing - DC-OK signal output Dimensions Type Width w Heigth h Depth d -- ++ DC-OK TPC 030 26.5 (1.04) 90 (3.54) 96.5 (3.80) TPC 055 45 (1.77) 90 (3.54) 96.5 (3.80) TPC-REM240-24 45 (1.77) 90 (3.54) 96.5 (3.80) DC-ON TPC 080 63 (2.48) 90 (3.54) 96.5 (3.80) V adj. TPC 120 72 (2.83) 90 (3.54) 110 (4.33) () = Inches PE NL w d 158 h www.tracopower.com DIN-Rail Mount AC/DC Power Supplies CB CB Scheme Scheme NKAA NKAA EMC ATEX II3G TSPC Series 50 to 480 W EN 61558 UL 508 IEC 60950-1 UL 60950-1 LVD EN 60204 Cost optimized design in rugged, compact metal casing for harsh industrial environments Operating temperature range –25 ° C to +70 ° C Boost power up to 120% Industrial safety approval package ATEX certification for hazardous locations Power Good signal Overload and over temperature protection Vibration and shock proof Specifications Models Order code Output power Output voltage Output current Input voltage range 85-132 VAC / 187-264 VAC by selection switch, 47-63 Hz max. nom. max. Line regulation 1.0% max. TSPC 050-112 12 VDC 4.0 A 50 W Load regulation 1.0 % max TSPC 050-124 24 VDC 2.1 A 50 W Ripple & Noise <200 mVpk-pk TSPC 080-112 12 VDC 6.6 A 80 W EMI emission EN 61204-3, EN 61000-6-3 TSPC 080-124 24 VDC 3.3 A 80 W EMC immunity EN 61204-3, EN 61000-6-2 (industrial environment), TSPC 120-124 24 VDC 5.0 A 120 W SEMI F47 TSPC 120-148 48 VDC 2.5 A 120 W Output current limitation at 120 % of Iout max. TSPC 240-124 240 W 24 VDC 10 A Over-temperature switch off at over-temperature, automatic restart. TSPC 240-148 48 VDC 5.0 A 240 W protection TSPC 480-124 24 VDC 20 A 480 W Over voltage protection 45 V TSPC 480-148 480 W 48 VDC 10 A Efficiency 90 % typ. Decoupling Module Operating temperature –25 ° C to +70 ° C above 60 ° C derating 2.5 %/K Order code Input voltage Input current Voltage drop across the diodes Safety standards / IEC/EN 60950-1, UL 60950-1, CSA 22.2 No 60950-1-07 TSPC-DCM600 5 - 28 VDC max. 25 A max. 0.75 V typ. / 1.2 V max. approvals UL 508, CSA-C22.2 No.107, EN 60204-1, EN 50178 EN 61558-2-4, EN 60079-15- II3G EX nA IIC T4 Degree of protection safety class I (IEC 536). The module contains two diodes Case protection IP20 (IEC 529) for redundant operation of two power supplies of any series. Vibration/Shock IEC 60068-2-6 / IEC 60068-2-27 There is no active current sharing Connection screw terminals and no signal output. Casing aluminium (chassis) / stainless steel (cover) www.tracopower.com/products/tspc-dcm.pdf Mounting – snap-on mounting on 35 mm DIN-Rail – wall mounting brackets (option) Full datasheet www.tracopower.com/products/tspc.pdf Wall mount brackets TSP-WMK03 for 80 - 240 W and -DCM models TSP-WMK02 for 480 W model Type Width w Heigth h Depth d TSPC 050 35.5 (1.45) 110 (4.33) 87 (3.56) -- ++ TSPC 080 40 (1.57) 110 (4.33) 110 (4.33) TSPC 120 46 (1.81) 110 (4.33) 110 (4.33) DC ON O/P Adjust TSPC 240 60 (2.36) 110 (4.33) 110 (4.33) TSPC 480 150 (5.90) 110 (4.33) 115 (4.53) TSPC-DCM600 54 (2.13) 110 (4.33) 110 (4.33) NL w 5.0 (0.20) d 159 NEW Models h www.tracopower.com AC/DC Power Supplies DIN-Rail Mount CB Scheme UL 60950-1 ATEX II3G IEC 60950-1 TSP Series 72 to 600 W UL 508 Rugged, ultra compact metal casing for harsh industrial environments Operating temperature range –25 ° C to +70 ° C Industrial safety approval package ATEX certification for hazardous locations (Opt.) Add-on function modules for system application Power Good signal, remote On/Off Overload and over temperature protection Vibration and shock proof Detachable screw terminal block Specifications Models 1) 2) 3) Order code Output power Output voltage Output current Input voltage range 85–264 VAC, 47–63 Hz, autorange max. nom. max. Line regulation 0.5 % max. TSP 070-112 72 W 12 VDC 6.0 A Load regulation 0.5 % max TSP 090-124 24 VDC 3.75 A Ripple & Noise <150 mVpk-pk 4) TSP 090-124N 24 VDC 3.75 A 90 W EMI emission EN 61204-3, EN 61000-6-3 TSP 090-148 48 VDC 2.0 A EMC immunity EN 61204-3, EN 61000-6-2 (indust. environment), SEMI F47 TSP 140-112 12 VDC 12.0 A Output current limitation at max. output current (constant current, automatic restart) TSP 180-124 24 VDC 7.5 A 180 W TSP 180-148 48 VDC 4.0 A Over-temperature switch off at over-temperature, automatic restart. protection TSP 360-124 24 VDC 15.0 A 360 W TSP 360-148 48 VDC 7.5 A Output characteristic selectable for parallel operation or battery charging application TSP 600-124 24 VDC 25.0 A Over voltage protection 20 V for 12 VDC models, 35 V for 24 VDC models, TSP 600-136 36 VDC 16.5 A 600 W 60V for 48 VDC models TSP 600-148 48 VDC 12.5 A 1) Efficiency 87 % typ. Suffix EX: For ATEX certified models (Example TSP 180-124 EX) 2) Output voltage adjustable 12-14 VDC, 24-28 VDC, 48-56 VDC Operating temperature –25 ° C to +70 ° C 3) Max. current at nominal output voltage and max. 40°C ambient temperature above 40 ° C derating see datasheet 4) Model meets EN 60950-1 sect. 2.5 and NEC Class2 (limited power source) Safety standards / IEC/EN 60950-1, UL 60950-1, CSA-C22.2 No. 60950-1-03 approvals UL 508, CSA-C22.2 No. 107, EN 60204, EN 50178, Add-on function modules EN 61558-2-4, with option -EX: UL 60079-15 (Class I, See page 163 Division 2, Groups A,B,C,D AEx n C II C T4 U), EN 60079-15 II3G EEX nAC IIC T4 Degree of protection safety class I (IEC 536). Case protection IP20 (IEC 529) Vibration/Shock IEC 60068-2-6 / IEC 60068-2-27 Connection detachable screw terminals Wall mount brackets TSP-WMK03 for 72 - 180 W models Casing aluminium (chassis) / stainless steel (cover) TSP-WMK02 Mounting – snap-on mounting on 35 mm DIN-Rail for 360 - 600 W models – wall mounting brackets (option) Full datasheet www.tracopower.com/products/tsp.pdf Dimensions Type Width w Heigth h Depth d TSP 070 / 090 35 (1.38) 110 (4.33) 110 (4.33) TSP 140 / 180 54 (2.13) 110 (4.33) 110 (4.33) TSP 360 80 (3.15) 125 (4.92) 125 (4.92) TSP 600 165 (6.50) 125 (4.92) 125 (4.92) w 5.0 (0.2) d () = Inches 160 h www.tracopower.com DIN-Rail Mount AC/DC Power Supplies CB CB Scheme Scheme EN 60950-1 UL 508 UL 60950-1 ATEX II3G IEC 60950-1 TSP-3P Series 240 – 960 W EN 61558-2-16 EN 60204 Low cost-weight-size alternative to 3-phase transformers 3AC 320–440 V or 3AC 400–550 VAC input ranges Rugged, ultra compact metal casing for harsh industrial environments Industrial safety approval package ATEX certification for hazardous locations Operating temperature range –25 ° C to +70 ° C 200% peak current for up to 5 seconds (electronic controlled) Power Good signal Overload and over temperature protection Specifications Models 240 W Models Input voltage ranges: 3 x AC 320–440 V or 3 x AC 400–550 V Order code Input voltage Output voltage Output current Line regulation 1.0 % max nom. nom. nom.* Load regulation 3.0 % max. TSP 240-124-3PAC400 24 VDC 10 A 3 AC 400 V Ripple & noise <100 mVpk-pk TSP 240-124-3PAC500 24 VDC 10 A 3 AC 500 V EMI emission EN 61000-6-3 480 W Models EMC immunity EN 61000-6-2 (industrial environment) Order code Input voltage Output voltage Output current Output current limitation at 220% of nominal current nom. nom. nom.* (constant current, automatic restart) TSP 480-124-3PAC400 24 VDC 20 A 3 AC 400 V Over-temperature switch off at over-temperature, automatic restart TSP 480-124-3PAC500 24 VDC 20 A 3 AC 500 V protection 960 W Models Over voltage protection at 35 VDC Order code Input voltage Output voltage Output current nom. nom. nom.* Efficiency 92% typ. TSP 960-124-3PAC400 24 VDC 40 A 3 AC 400 V Operating temperature –25° C to +70° C TSP 960-124-3PAC500 24 VDC 40 A above 60° C derating 2.5 %/K 3 AC 500 V Safety standards / cUL/UL 60950-1 recognized, IEC/EN 60950-1, UL 508, *200% peak current for up to 5 sec. approvals (CB-Report), EN 50178, EN 60204, EN 61558-2-4, FM 3611, EN 60079-15, ANSI/ISA 12.12.01 (Class l, Div. 2), ATEX 94/9/EC Wall mount brackets Degree of protection safety class I (IEC 536) TSP-WMK03 for 240 W models Case protection IP20 (IEC 529) TSP-WMK02 for 480 - 960 W models Vibration/Shock IEC 60068-2-6 / IEC 60068-2-27 Connection detachable screw terminals Casing aluminium (chassis) / stainless steel (cover) Mounting – snap-on mounting on 35 mm DIN-Rail – wall mounting brackets (option) Full datasheet www.tracopower.com/products/tsp3p.pdf Dimensions Type Width w Heigth h Depth d TSP 240 54 (2.13) 110 (4.33) 110 (4.33) TSP 480 80 (3.15) 125 (4.92) 125 (4.92) TSP 960 165 (6.50) 125 (4.92) 125 (4.92) () = Inches w 5.0 (0.2) d 161 h www.tracopower.com AC/DC Power Supplies DIN-Rail Mount CB Scheme TSP-WR Series 180 to 600 W IEC 60950-1 UL 60950-1 UL 508 For worldwide operation, with ultra wide input voltage ranges from 100 to 500 VAC, for single phase and two phase operation Rugged, ultra compact metal casing for harsh industrial environments Operating temperature range –25 ° C to +70 ° C Industrial safety approval package Add-on function modules for system application Overload and over temperature protection Power Good signal, remote On/Off Vibration and shock proof Detachable screw terminal block Specifications Models Applicable 3-phase – TN, TT: 500 VAC Star configuration (EN60950+UL508) 1) 2) 2) Order code Output power Output voltage Output current networks 500 VAC Delta (UL508 only) max. nom. max. – IT: 400 VAC Delta (IEC-62103) TSP 180-124WR 24 VDC 7.5 A 180 Watt 230 VAC Delta (IEC-60950) TSP 360-124WR 24 VDC 15.0 A 360 Watt 500 VAC (UL508 only) TSP 600-124WR 24 VDC 25.0 A 600 Watt Input voltage ranges 85–132 VAC / 187–264 VAC / 323-550 VAC 1) Output voltage adjustable 24-28 VDC Line regulation 0.5 % max 2) Max. current at nominal output voltage and max. 40°C ambient temperature Load regulation 0.5 % max. Ripple & noise <150 mVpk-pk EMI emission EN 61204-3, EN 61000-6-3 Add-on function modules EMC immunity EN 61204-3, EN 61000-6-2 (industrial environment), SEMI F47 See page 163 Output current limitation at max. output current (constant current, automatic restart) Over-temperature switch off at over-temperature, automatic restart protection Output characteristic selectable for parallel operation or battery charging application Wall mount brackets Efficiency 88 % typ. TSP-WMK03 for 180 W models Operating temperature –25 ° to +70 ° C TSP-WMK02 for 360 - 600 W models above 40 ° C derating see datasheet Safety standards / cUL/UL 60950-1 recognized, UL 508, IEC/EN 60950-1, approvals (CB-Report), EN 50178, EN 60204, EN 61558-2-16, FM 3611, IEC/EN 60079-15 (Class l, Div. 2) Degree of protection safety class I (IEC 536) Case protection IP20 (IEC 529) Vibration/Shock IEC 60068-2-6 / IEC 60068-2-27 Connection detachable screw terminals Casing aluminium (chassis) / stainless steel (cover) Mounting – snap-on mounting on 35 mm DIN-Rail – wall mounting brackets (option) Full datasheet www.tracopower.com/products/tsp-wr.pdf Dimensions Type Width w Heigth h Depth d TSP 180 54 (2.13) 110 (4.33) 110 (4.33) TSP 360 80 (3.15) 125 (4.92) 125 (4.92) TSP 600 190 (7.48) 125 (4.92) 125 (4.92) w 5.0 (0.2) d () = Inches 162 h www.tracopower.com DIN-Rail Mount AC/DC Power Supplies TSP / TSP-WR Series Function Modules TSP-REM: Module for true current sharing operation Alarm outputs, redundancy OK signal Hot swappable inputs TSP-BCM: Battery protection for over voltage, deep discharge, short circuit and reverse connection Alarm outputs for input, output and battery condition TSP-BAT: Battery pack for TSP-BCM battery controller modules Specifications Description Models Models Redundancy Module Order code Input Max. power Output power Output voltage per input max. Redundancy Modules With this module and two power supplies of the TSP series TSP-REM360 360 W 24 VDC 360 W a highly reliable, true redundant power system can be 2 x 24 VDC { configured without any additional components.This TSP-REM600 2 x Control 600 W (24 – 27 VDC) 600 W module provides: Battery Controller Modules Order code Input Max. power Output voltage Output power - Operation with true current sharing nom. max. - Alarm outputs and redundancy OK signal TSP-BCM12 180 W 12 VDC 180 W 12 VDC and - Hot swappable inputs can be loaded up to 15 A each TSP-BCM24 360 W 24 VDC 360 W 24 VDC and { (resp. 25 A with model TSP REM600) TSP-BCM24A 24 V Battery 600 W 24 VDC 600 W TSP-BCM48 360 W 48 VDC 360 W 48 VDC and { TSP-BCM48A 48 V Battery 600 W 48 VDC 600 W Full datasheet: www.tracopower.com/products/tsp-rem.pdf Battery Pack Order code Nominal voltage Charge current Nominal capacity max. (at 25°C, 77°F) This module provides a professional battery controller to TSP-BAT12-072 1.08 A 7.2 Ah 12 VDC TSP-BCM charge and monitor an external lead-acid battery. TSP-BAT24-012 0.30 A 1.2 Ah Together with a power supply of the TSP series and a TSP-BAT24-034 0.51 A 3.4 Ah battery pack a perfect DC-UPS system can be configured. TSP-BAT24-072 1.08 A 7.2 Ah This module provides: 24 VDC TSP-BAT24-120 1.80 A 12.0 Ah - Battery protection for over voltage, deep discharge, TSP-BAT24-072KIT Installation rack without batteries short circuit and reverse connection TSP-BAT24-120KIT Installation rack without batteries - Remote On/Off for battery and power supply Buffer Module - Alarm outputs for input, output and battery condition Order code Input voltage Buffer time Output voltage Output power - Controlled end of charge voltage by temperature sensor 200 ms typ. @ 25 A 600 W TSP-BFM24 24 VDC nom. 24 VDC Battery Packs 4.0s max. @ 1.2A 25 A max. Sealed, maintenance free Lead-Acid batteries incl. wall mounting kit. Available with 1.2, 3.4, 7.2 and 12 Ah capacity. Dimensions Function Modules Type Width Heigth Depth TSP-REM360 35 (1.38) 110 (4.33) 110 (4.33) Full datasheet: www.tracopower.com/products/tsp-bcm.pdf TSP-REM600 54 (2.13) 110 (4.33) 110 (4.33) TSP-BCM212 35 (1.38) 110 (4.33) 110 (4.33) This module will maintain the output voltage of a 24 VDC TSP-BCM24 35 (1.38) 110 (4.33) 110 (4.33) TSP-BFM power supply during typical mains faults, short time TSP-BCM24A 54 (2.13) 110 (4.33) 110 (4.33) blackouts or voltage dips of up to ten full 50 Hz cycles. TSP-BCM48 35 (1.38) 110 (4.33) 110 (4.33) During this buffer period no deterioration of the 24 VDC TSP-BCM48A 54 (2.13) 110 (4.33) 110 (4.33) output voltage will occur. This module provides: TSP-BFM24 54 (2.13) 110 (4.33) 110 (4.33) - Capacitor bank for energy storage, no battery needed! - Maintenance free, long lifetime, high performance also Dimensions Battery Packs at low temperature. Type Width Heigth h Depth - Guaranteed Hold-up-time 200 ms/25 A to 4 s/1.2 A max. TSP-BAT24-034 137 (5.39) 140 (5.51) 76 (2.99) - Output 24 to 28 VDC, 600 W max. TSP-BAT24-072 133 (5.24) 157 (6.18) 110 (4.33) - Active ready and inhibit signals TSP-BAT24-120 199 (7.83) 157 (6.18) 110 (4.33) Full datasheet: www.tracopower.com/products/tsp-bfm.pdf 163 NEW Models www.tracopower.com AC/DC Power Supplies DIN-Rail Mount CB Scheme UL 60950-1 UL 508 TIS Series 50 to 600 W UL 1604 Low profile metal casing Standard models with 12, 24, 48 and 72 VDC For system applications expandable with built-in function modules (see datasheet) Adjustable output voltage Overload protection Worldwide safety approvals Specifications Specifications Models Models Order code Output power Output voltage Output current Input voltage range – 93–132 VAC / 187–264 VAC (user selectable) 50/60 Hz max. (adjustable range) max. – TIS 50 models: 93–264 VAC (universal input) 50/60 Hz TIS 50-112 50 Watt 12 VDC (12–14 VDC) 3.5 A – TIS 500-124-230: 187–264 VAC 50/60 Hz TIS 50-124 24 VDC (24–28 VDC) 2 A – TIS 500-124-115: 93–132 VAC 50/60 Hz / 113 - 187 VDC TIS 75-112 12 VDC (12–14 VDC) 6 A Line regulation 0.2 % max. TIS 75-124 75 Watt 24 VDC (24–28 VDC) 3 A Load regulation 1.0 % max. TIS 75-148 48 VDC (48–52 VDC) 1.5 A Ripple & noise <50 mVpk-pk (20 MHz BW) TIS 150-124 150 Watt 24 VDC (24–28 VDC) 6 A EMI suppression EN 55011, class B, EN 55022, class B and FCC,level B TIS 150-148 48 VDC (48–52 VDC) 3 A TIS 300-124 24 VDC (24–28 VDC) 12 A EMC immunity EN 61000-6-2 TIS 300-148 300 Watt 48 VDC (48–52 VDC) 6 A Output current limitation at 110 % of Iout max. (constant current) TIS 300-172 72 VDC (60–76 VDC) 4.2 A Overvoltage protection at 140 % of Vout nom. TIS 500-124-230 500 Watt 24 VDC (24–28 VDC) 20 A Efficiency 90 % typ. TIS 500-124-115 24 VDC (24–28 VDC) 20 A Operating temperature –25°C to +70°C TIS 600-124 24 VDC (24–28 VDC) 24 A above 50°C derating 2% / K TIS 600-148 600 Watt 48 VDC (48–52 VDC) 12 A Safety standard / cUL/UL 60950-1, UL 508C listed, UL 1604 listed (except for TIS 600-172 72 VDC (60–76 VDC) 8.5 A approvals models with options), IEC/EN 60950-1, CB-report Models with internal redundancy module Connection detachable screw terminals (plugs included) TIS 150-124 RED 150 W 24 VDC 6 A (TIS 600 models: screw terminal blocks) TIS 150-148 RED 150 W 48 VDC 3 A Casing stainless steel, aluminium TIS 300-124 RED 300 W 24 VDC 12 A TIS 300-148 RED 300 W 48 VDC 6 A Mounting snap-on mounting on 35 mm DIN-Rail or chassis mounting TIS 600-124 RED 600 W 24 VDC 24 A Note Output current characteristics suitable for battery charging TIS 600-148 RED 600 W 48 VDC 12 A applications Models with internal battery bontroller module Full datasheet www.tracopower.com/products/tis.pdf TIS 300-124 UDS 300 W 24 VDC 12 A TIS 600-124 UDS 600 W 24 VDC 24 A Battery Pack TIS 24-32 AP 24 VDC 3.2 Ah TIS 24-70 AP 24 VDC 7 Ah * oder code for power supply with built in function module and terminal plugs Dimensions Type Width w Heigth h Depth d TIS 50 75 (2.95) 100 (3.94) 56.7 (2.23) TIS 75 90 (3.54) 114.6 (4.51) 56.7 (2.23) TIS 150 157 (6.18) 114.6 (4.51) 56.7 (2.23) TIS 300 207 (8.15) 114.6 (4.51) 83.0 (3.27) Output OK TIS 500 220 (8.66) 130 (8.66) 83.0 (3.27) TIS 600 243 (9.57) 177.2 (6.98) 83.0 (3.27) () = Inches w 5 (0.2) d 164 h www.tracopower.com DIN-Rail Mount AC/DC Power Supplies CB Scheme UL 60950-1 TFP Series 250 to 750 W IEC 60950-1 ATEX II3G UL 508 Robust and compact low profile Low heat dissipation and a high efficiency of 92% typical Worlwide Safety approval package. ATEX certification Wide AC and DC input voltage range 85 – 264 VAC and 90 – 280 VDC Industrial operating temperature range: –40 °C to +70 °C Active isolation diode Mains current with power factor >98% Extended functional features (opt.) Specifications Models Order code Output power Output voltage Output current Input voltage range 85–264 VAC (50/60 Hz) / 90–280 VDC max. (adjustable range) max. Line regulation 0.5 % max. TFP 250-124 250 W 24 VDC (24–28,8 VDC) 10 A Load regulation 1.0 % max. TFP 500-124 500 W 24 VDC (24–28,8 VDC) 20 A Ripple & noise <100 mVpk-pk (20 MHz BW) TFP 750-124 750 W 24 VDC (24–28,8 VDC) 30 A EMI suppression EN 55011, class B, EN 55022, class B and FCC, class B Options: EMC immunity EN 61000-6-2 –CS: Active current share module –CAN: CAN-bus interface and current share function Output current limitation at 110 % of Iout max. (constant current) –NET: Lan interface current share function Overvoltage protection at 140 % of Vout nom. –BC: Battery charger module Efficiency 92 % typ. Operating temperature –40 °C to +70 °C above 60°C derating 3% / K Safety standard / IEC/EN 60950-1, UL 60950-1, CSA 22.2 No. 60950-1-03 approvals UL 508, CSA-C22.2 No.107, EN 60204-1, EN 61552-2-4 IEC/EN 60079-15 Connection detachable screw terminals (plugs included) Casing stainless steel, aluminium Mounting snap-on mounting on 35 mm DIN-Rail or chassis mounting Note Output current characteristics suitable for battery charging applications Full datasheet www.tracopower.com/products/tfp.pdf Dimensions Type Width w Heigth h Depth d TFP 250 176 (6.93) 111 (4.37) 62. (2.44) TFP 500 200 (7.87) 125 (4.92) 62 (2.44) TFP 750 250 (9.84) 125 (4.92) 62 (2.44) Output OK 5 (0.2) w d 165 NEW Product h www.tracopower.com AC/DC Power Supplies DIN-Rail Mount TSP-BCMU360 / TSPC-240UPS Series UPS Systems TSP-BCMU360: Universal battery controller module for uninterruptable 24 VDC and 48 VDC bus voltage Redundant inputs for two indepedant sources TSPC-240UPS: Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit and reverse connection Alarm outputs for input, output and battery condition Remote On/Off for battery and power supply Description Models TSP-BCMU360 The TSP-BCMU360 module extends any 24VDC or 48VDC Order code Input Max. power Output voltage Output power nom. max. power supply to a DC-USP (uninterruptable DC Power supply). This module is a standalone unit and is designed 24 or 48 TSP-BCMU360 600 W 24 or 48 VDC 600 W to function with the Traco TSP series; however it can be VDC or Battery used in conjunction with any fully stabilized 24V or 48V DC power supply output. The module also offers the unique feature of redundant inputs as well as the battery backup. Redundancy is achieved by two internal decoupling diodes which allow operation with two independent voltage sources in order to increase the reliability of the output even further. Full datasheet: www.tracopower.com/products/tsp-bcmu360.pdf Models Order code Input Max. power Output voltage Output current TSPC-240UPS This power supply provides an integrated professional nom. max. battery management system to charge and monitor an 85–132 VAC external lead-acid battery. The result is a complete DCUPS TSPC 240-124 UPS 240 W 24 VDC 12 A 187–264 VAC system in a compact housing with no additional parts needed. The external connected 12 V battery will be * A 12 VDC lead acid back up battery is required (to purchase on local market no Traco Power stocking item) charged and held in charged mode by the power supply. In the event of a mains power failure the battery will supply the output power until the battery is discharged. As a consequence, the output voltage of the system is equivalent to the battery voltage. To avoid overcharging the battery, an external temperature sensor adjusts the battery voltage automatically to the required end of charge voltage. This can extend the battery life. The battery is protected against deep discharge. Input voltage range 85–132 / 187–264 VAC (autorange) Dimensions Function Modules Output regulation 1 % max. Ripple & noise <100 mVpk-pk (20 MHz BW) Type Width Heigth Depth Output current limitation >120% of Iout nom. TSPC 240-124 UPS pending pending pending Over voltage protection at 30 VDC TSP-BCMU360 54 (2.13) 110 (4.33) 110 (4.33) Efficiency 90 % typ. Operating temperature –25 ° C to +70 ° C above 60 ° C derating 2 .5%/K Safety standards / IEC/EN 60950-1, cUL/UL 508 listed approvals Full datasheet www.tracopower.com/products/tspc-240ups.pdf 166 NEW Product Traco Electronic AG T +41 43 311 45 11 Sihlbruggstrasse 111 F +41 43 311 45 45 6340 Baar info@traco.ch Switzerland tracopower.com

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the TSP-BAT24-072KIT?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

100 W, Single Output, 5 VDC@20 A AC-DC Power Supply

product

100 W, Single Output, 12 VDC@8.6 A AC-DC Power Supply

product

100 W, Single Output, 15 VDC@7 A AC-DC Power Supply

product

100 W, Single Output, 24 VDC@4.4 A AC-DC Power Supply

product

100 W, Single Output, 48 VDC@2.2 A AC-DC Power Supply

product

150 W, Single Output, 5 VDC@30 A AC-DC Power Supply