Electronics Finder chervon right Manufacturers chervon right T chervon right TRACO POWER chervon right TSPC240-124UPS
About product Specifications Datasheet FAQ

TRACO POWER TSPC240-124UPS

Image of TRACO POWER TSPC240-124UPS

Description

240 W, Single Output, 24 VDC@10 A AC-DC Power Supply

Part Number

TSPC240-124UPS

Price

Request Quote

Manufacturer

TRACO POWER

Lead Time

Request Quote

Category

Circuit Protection »  AC-DC Power Supply

Specifications

Manufacturer

Traco Power

Manufacturers Part #

TSPC240-124UPS

Brand

TRACO POWER

Series

TSPC

Factory Pack Quantity

1

Cooling Method

Convection

Dimensions

4.33 x 2.36 x 4.33"

Input Voltage Nominal

240 VAC, 100 VAC

Mechanical Style

DIN Rail Mount

Mounting

DIN Rail

Number of Outputs

1

Operating Temperature

- 25 to + 70°C

Output Amps 1

10 A

Output Voltage V1 Nominal

24 VDC

Power

240 W

Subcategory

AC-DC Power Supply

Datasheet

pdf file

tspc-240ups-datasheet.pdf

838 KiB

Extracted Text

UPS Uninterruptable AC/DC Power Supply TSPC-240UPS Series ◆ Compact universal power supply for uniterruptable 24 VDC output voltage ◆ Battery protection for over voltage, deep discharge, short circuit and reverse connection ◆ Alarm outputs for input, output and battery condition ◆ Remote On/Off for UPS function and power supply ◆ Controlled end of charge voltage by battery temperature sensor ◆ International safety approval package ◆ Suitable for various external 12 VDC CB Scheme NKAA lead acid batteries EMC IEC 60950-1 UL 60950-1 EN 60950-1 UL 508 ATEX II3G LVD EN 61558 EN 60204 This power supply provides an integrated professional battery management system to charge and monitor an external lead-acid battery. The result is a complete DC- UPS system in a compact housing with no additional parts needed. The external connected 12 V battery will be charged and held in charged mode by the power supply. In the event of a mains power failure the battery will supply the output po- wer until the battery is discharged. To avoid overcharging the battery, an external TSP-TS battery temperature sensor temperature sensor adjusts the battery voltage automatically to the required end (10 kOhm NTC with 2m cable) optional of charge voltage. This can extend the battery life. The battery is protected against deep discharge. Mains power and battery status are monitored regularly and failu- res indicated by corresponding LED’s and alarm outputs. The module also provides an external On/Off input to switch-off both, power supply and battery. Models Output current Output Power Order code Input voltage range Back up battery max.* max. Low Line : 85 – 132 VAC 12V lead acid battery (to purchase on local 24 VDC / 12 A TSPC 240-124 UPS 240 W High Line: 187 – 264 VAC market, no TRACO POWER stocking item) * Maximum current at nominal Vout http://www.tracopower.com Page 1 of 7 TSPC-240UPS Series Input Specifications Input voltage – nominal ranges 100 – 120 / 220 – 240 VAC by selection switch – effective ranges 85 – 132 / 187 – 264 VAC (output current derating at low input voltage see page 6) Input voltage frequency 47 – 63 Hz Harmonic limits EN 61000-3-2 Holdup time 10 ms min. Inrush current 40 A Recommended circuit breaker, 16.0 A max. characteristic B or C or slow blow fuse Output Specifications Output voltage / current – normal mode 24.0 – 26.0 VDC; 10 A (12 A in boost mode) – buffer mode 23.4 – 23.8 VDC; 10 A (12 A in boost mode) – output power derating above 24 VDC 5 %/V Efficiency – normal mode 88 – 91 % (battery charged) (load >50 % of Iout max.) – buffer mode 90 – 92 % Regulation – Input variation 1 % max. – Load variation (0–100 %) 1 % max. Ripple and Noise (20MHz bandwidth) 100 mVp-p max. Overload protection 120 – 140 % of Iout nom., constant current Short circuit current 90 % of Iout nom. (typ.), foldback Output overvoltage protection 45 V Overtemperature protection switch off at overtemperature, automatic restart Power back immunity 35 V (40 V for 1 sec.) Power OK signal – trigger threshold: 21.0 – 22.5 V – output signal open collector 10 mA max. Max. capacitive load unlimited General Specifications Operating temperature – operation in normal & buffer mode –25°C to +70°C max. derating above +60ºC : 2.5%/K – normal mode boost output –25°C to +60°C max. derating above +50°C : 1.67 %/K – buffer mode boost output –25ºC to +40ºC max. Storage temperature –25°C to +85°C max. Temperature coefficient 0.02 %/K Cooling convection cooling, no internal fan Pollution degree 2 Humidity (non condensing) 95 % rel. H max. Reliability, calculated MTBF at +25°C acc. to IEC 61709 > 1.1 Mio. h Battery protection against over voltage, deep discharge, overcharge, short circuit and reverse connection (built-in fuse) Signals – Status DC OK input, DC OK output, BAT OK all relay contact closed and LED on at status OK – Contact rating 30 VDC / 1.0 A max. 60 VDC / 0.5 A max. All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 2 of 7 TSPC-240UPS Series General Specifications (continued) Battery charging current 0.8 – 1.2 A Nominal battery voltage (at 25ºC) 13.6 VDC (factory setting) Battery voltage adjustment range 13.0 – 14.4 VDC Battery restistance test 100mOhm min. (normal mode at 25ºC) Battery test current 2.5A / 60ms typ. (normal mode at 25ºC) Battery test interval (acc. to jumper setting) 15s or 10min Battery warning 10.4 – 11.4 VDC (buffer mode only) Battery disconnection 9.3 – 10.2 VDC (buffer mode only) Battery remote Off disconnects battery in buffer mode (see page 6 - connector) Automatic battery temperature compensation range –15ºC – 50ºC Altitude during operation 2000 m Isolation according to IEC/EN 60950-1, UL 60950-1, UL 508 Safety standards – Information technology equipment IEC/EN 60950-1, UL 60950-1, CSA 22.2 No 60950-1-07 – Industrial control equipment UL 508, CSA-C22.2 No.107 – Electrical equipment for machines EN 60204-1 – Electronic equipment for power installation EN 50178 – Safety of transformers EN 61558-2-6, EN 61558-2-16 – Control equipment for hazardous location EN 60079-15 II3G EX nA IIC T4 – ATEX (for IP 54 enclosure) certificate no. EPS 10 ATEX 1 269 X – Certification documents www.tracopower.com/overview/tspc-ups Class of protection safety class I (IEC 536) Degree of protection IP 20 (IEC/EN 60529) Electromagnetic compatibility (EMC), Emissions EN 61000-6-3, EN 61204-3 – Conducted RI suppression on input EN 55011 class B, EN 55022 class B, – Radiated RI suppression EN 55011 class B, EN 55022 class B, Electromagnetic compatibility (EMC), Immunity EN 61000-6-2, EN 61204-3 – Electrostatic discharge (ESD) IEC/EN 61000-4-2 4 kV / 8 kV criteria B – Radiated RF field immunity IEC/EN 61000-4-3 10 V / m criteria A – Electrical fast transient / burst immunity IEC/EN 61000-4-4 2 kV criteria B – Surge immunity IEC/EN 61000-4-5 1 kV / 2 kV criteria B – Immunity to conducted RF disturbances IEC/EN 61000-4-6 10 V criteria A – Power frequency field immunity IEC/EN 61000-4-8 30 A / m criteria A – Mains voltage dips and interruptions IEC/EN 61000-4-11 criteria A Environment – Vibration acc. IEC 60068-2-6; 3 axis, sine sweep, 10 – 55 Hz, 1 g, 1 oct/min – Shock acc. IEC 60068-2-27 3 axis, 15 g half sine, 11 ms Enclosure material aluminium (chassis) / stainless steel (cover) Mounting – DIN-rail mounting for DIN-rails as per EN 50022-35x15/7.5 (snap-on with self-locking spring) Environmental compliance – Reach www.tracopower.com/overview/tspc-ups – RoHS RoHS directive 2011/65/EU Connection – Input output battery screw terminal (plug included) – Signal & control detachable screw terminals (plugs included) All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. http://www.tracopower.com Page 3 of 7 TSPC-240UPS Series Function Specification Function Diagram: General Description This power supply is supplied by mains voltage and contains an integrated DC uninterruptible power supply feed by an external bat- tery. It is designed to supply the applied load continuously and without interruption, even when the mains power fails. In this case, the energy is supplied from an external 12V battery to provide the required output voltage. The unit is designed to operate with lead-acid batteries Operation Before the first use, the AC input range should be set by the slide switch. During the normal operation, when the input AC voltage is present, the output DC voltage is delivered by internal AC/DC power supply. In case of power failure the internal battery discharge regulator is activated. The output voltage will be still maintained at the reduced level of 23.6V (typically at Vnom) without any interruptions. The battery discharge operation will continue until AC input voltage reco- vers. If the input AC voltage does not recover, the battery voltage will continue to drop, while continuously delivering the output power at re- quired voltage level. In order to prevent the deep discharge of the battery, which can lead to battery failure, the battery is disconnected at the deep discharge threshold. The BAT OK signal will be OFF when the battery voltage is approaching the disconnection voltage level. This can enable early warning of the system. If the input AC is present at the right level, the battery is automatically charged to the set voltage level. This level is factory set for 25ºC for lead-acid batteries. The user can change this voltage by using the built-in potentiometer. The adjustment can be made only if the battery is disconnected (after initial operation) to prevent from adjustments errors. The battery test interval should be set to 10 minutes (factory settings). If the battery is operating at a different ambient temperature (not 25ºC), the user can adjust the set battery voltage to the required ambient temperature, as recommended by the battery manufacturer. After adjustments – the battery should be re-connected. It is also possible to use the temperature compensation probe to automatically compensate the end battery charge voltage for any temperature changes. In this case, there is no need to change the potentiometer to compensate for a new ambient temperature. The internal state of charge of the battery is tested at regular intervals with internal current pulse. The interval is factory set to 10 mi- nutes. It can be changed to 15s for test purposes by changing the slide switch position on the front of the unit as indicated on the label. If the battery OK signal is OFF, even after prolonged charging, the battery pack needs replacement. The buffer function (during input power failure) can be disabled remotely, and the battery is disconnected. It can be achieved by pulling the Remote ON/OFF pin to GND (with contact relay or transistor). http://www.tracopower.com Page 4 of 7 TSPC-240UPS Series Function Specification (continued) Signals Following signals are made available as LED indicators and corresponding isolated relay contacts: AC-OK Indicates if the input AC voltage is present. During operation outside the DC specification (overload), at low input AC levels (below nominal range) it can be OFF. It will indicate that the battery operation has started in order to maintain the output voltage at 24V level. BATT-OK: Indicates if the battery is charged properly and has low internal resistance. During battery discharge operation this signal monitors the battery voltage. If the battery voltage approaches the disconnection voltage – it is OFF. This ena bles early warnings of the system. The threshold of this signal is about 1V higher than the battery disconnection voltage. Note that if the battery signal was OFF during the normal operation (when input voltage is present) – it will stay OFF during the battery discharge operation as well. DC-OUT-OK: Indicates that the output voltage is higher than 82–90% of the nominal output voltage. Battery When the input AC voltage is present, the TSPC-240UPS unit will automatically charge the connected battery to a set end of battery charge voltage level, factory set for 25ºC for lead-acid batteries, using a constant current charging method of 1A (typical). As the battery voltage approaches the end of battery charge voltage level, the current will decrease proportionally; this characteristic is shown in Fig 1. The user can adjust the set end of battery charge voltage level by means of the “Battery Voltage Adjust” potentiometer. The module also provides an input connector for a temperature compensation probe. If this probe is connected, the unit will automati- cally compensate the end of battery charge voltage level depending on the measured temperature. The connection of the temperature probe also negates the need to change the potentiometer to compensate for a new temperature. The battery end voltage compensation curve is shown in Fig. 2. (Applicable to factory setting of 13.6V/ 25ºC) Battery End of Charge Voltage with Temperature Sensor [V] 15.0 14.8 14.6 14.4 14.2 14.0 End of Charge Voltage 13.8 13.6 13.4 13.2 13.0 -15-10 -5 05 10 15 20 25 30 35 40 45 50 [ºC] Figure 1 Figure 2 Battery Protection The module protects the connected battery against short circuit and overload by the means of a built in 30A fuse. This fuse is a stan- dard 30A blade type fuse, which is accessible from the front panel of the unit for ease of replacement should the fuse be damaged during operation. It also prevents deep discharge of the battery by disconnecting the battery from the load once the voltage level of battery has dropped below a defined threshold. An early warning of this disconnection is given to the user by means of the BATT-OK signal (see chapter 2.6.2). The BATT-OK signal will switch off when the battery voltage is roughly 1V above the deep discharge threshold. http://www.tracopower.com Page 5 of 7 TSPC-240UPS Series Function Specification (continued) Remote On/Off The TSPC-240UPS module provides a Battery Remote on/off input (2 pins on signalconnector); if this input is short circuited (switch closed in Fig. 3) the battery will be disconnected from the unit by means of an internal relay. A voltage of 0.5V or less across the Battery Remote on/off terminals will disconnect the battery from the unit. If the Battery Remote On/Off signal is set to off (short bet- ween pins) this will not affect the output of the unit in normal mode, however the battery will be disconnected, hence it will not charge. If the unit enters buffer mode while the Battery Remote On/Off signal is off, the battery will remain disconnected, hence no energy will be supplied to the load. Battery State Battery Remote On/Off Pins Voltage Connected Open Circuit 5V Disconnected Short Circuit < 0.5V Figure 3 Ambient temperature and power rating The module operates at temperatures between –10ºC and +60ºC, with a minimum start-up temperature of –25ºC. In normal mode the module can deliver full power up to 60ºC. The boost current of 12A is available at ambient temperatures up to 50ºC with a derating of 1.67%/°C for temperatures above 50°C, as shown in Fig. 4. In buffer mode the module can deliver full power up to 60ºC with the boost current of 12A available at ambient temperatures up to 40ºC as shown in Fig. 5. Output Current Derating +24V at Low Line (85-132VAC) 140 120 100 80 Nominal Boost 60 40 20 Figure 4 Figure 5 0 85 90 95 100105 110115 120 125130 Input [VAC] Figure 2 Output Current Derating +24V at High Line (187-264VAC) Output Current Derating +24V at Low Line (85-132VAC) 140 140 120 120 100 100 80 80 Nominal Nominal Boost Boost 60 60 40 40 20 20 0 0 85 90 95 100105 110115 120 125130 180190 200210 220 230 240 250 260 Input [VAC] Input [VAC] Figure 3 Figure 2 Figure 6 Figure 7 Output Current Derating +24V at High Line (187-264VAC) 140 http://www.tracopower.com Page 6 of 7 120 100 80 Nominal Boost 60 40 20 0 180190 200210 220 230 240 250 260 Input [VAC] Figure 3 Output DC Current [%] Output DC Current [%] Output DC Current [%] Output DC Current [%] TSPC-240UPS Series Connector Position A Battery Temp. Remote ACI-IN Bat OK DC OK Semsor ON/OFF OK 13 2 4 57 6 81 9 0 DETAIL A INPUT VOLTAGE SELECT bottom view Outline Dimensions Signal Connector 13.9 18.8 9 3.8 Weight: 1400 g (49.4 oz) 13.9 INPUT VOLTAGE SELECT 120 ±1 76.2 * Measurement from front panel to DIN Rail 75.5 114 ±1* 73.1 110 ±1 12.9 Indust rial Powe r Su pp ly 15 se c DIN Rail Ba tt er y Co nt ro ller Ba tt er y Test DIN Rail Inte rv al Hook Hook 10 min AC -O K 24 - 26 V BA TT -O K DC -O K Mo del TS PC 240 -1 24 UP S Ba tt er y Vo lt ag e Adju st F3 0A 10 0-12 0/ 22 0 - 24 0 VA C 13 ,6 V/ 30 A 24 V/ 10 A 5.1/ 2.5 A 50 /6 0 Hz BA TT -IN OU TP UT NL -- ++ 12.2 23 9.5 10.2 M2 Combi Head M3 Combi Head M4 Combi Head (QTY: 10) (QTY: 10) (QTY: 4) © Copyright 2017 Traco Electronic AG Specifications can be changed without notice! Rev. June 27. 2017 www.tracopower.com Page 7 of 7 7.8 10 100 ±1 23 12.2 3.6 71.2 6.7 8.5

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the TSPC240-124UPS?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

100 W, Single Output, 5 VDC@20 A AC-DC Power Supply

product

100 W, Single Output, 12 VDC@8.6 A AC-DC Power Supply

product

100 W, Single Output, 15 VDC@7 A AC-DC Power Supply

product

100 W, Single Output, 24 VDC@4.4 A AC-DC Power Supply

product

100 W, Single Output, 48 VDC@2.2 A AC-DC Power Supply

product

150 W, Single Output, 5 VDC@30 A AC-DC Power Supply