CRYDOM CWD4825
Specifications
Manufacturer
Crydom
Manufacturers Part #
CWD4825
Industry Aliases
CWD4825
Sub-Category
Solid State Relays
Factory Pack Quantity
10
Datasheet
Extracted Text
Panel Mount Datasheet CW48 Series • Ratings from 10 A to 125 A @ 48-660 VAC • AC or DC control and Universal • SCR Output for heavy industrial loads AC/DC control • LED Status Indicator • EMC Compliant to Level 3 • UL/CSA/TUV Approved, CE Compliant to EN60950-1 • Epoxy Free Design • Improved SEMS screw and washer • Removable IP20 touch-safe cover • Redesigned housing with anti-rotation barriers • DBC substrate for superior thermal performance For Generation 3 datasheet click here PRODUCT SELECTION Control Voltage 10 A 25 A 50 A 90 A 125 A 4-32 VDC CWD4810 CWD4825 CWD4850 CWD4890 CWD48125 90-280 VAC CWA4810 CWA4825 CWA4850 CWA4890 CWA48125 18-36 VAC CWA4810E CWA4825E CWA4850E CWA4890E CWA48125E 20-48 VDC/20-280 VAC CWU4810 CWU4825 CWU4850 CWU4890 CWU48125 AVAILABLE OPTIONS Control Voltage D: 4-32 VDC U: 20-48 VDC or 20-280 VAC Thermal Pad A: 90-280 VAC Blank: Not Included Series AxxxxE: 18-36 VAC H: Included P H -10 CW D 48 10 E Operating Rated Load Current Overvoltage Protection Switching Type Voltage 10: 10 Amps Blank: Not Included Blank: Zero Voltage Turn-On Required for valid part number 48: 48-660 VAC 25: 25 Amps P: Included (1) -10: Instantaneous Turn-On For options only and not required for valid part number 50: 50 Amps Not all part number conbinations are available. * 90: 90 Amps Contact Crydom Technical Support for information on 125: 125 Amps the availability of a specific part number. (2) OUTPUT SPECIFICATIONS Description 10 A 25 A 50 A 90 A 125 A Operating Voltage (47-440Hz) [Vrms] 48-660 48-660 48-660 48-660 48-660 Transient Overvoltage [Vpk] (1) 1200 1200 1200 1200 1200 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 1 1 1 1 1 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec) 500 500 500 500 500 Maximum Load Current [Arms] (3) 10 25 50 90 125 Minimum Load Current [mArms] 150 150 150 250 250 Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 380/400 570/600 810/850 1290/1350 1900/2000 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.3 1.3 1.3 1.3 1.25 Thermal Resistance Junction to Case (Rjc) [°C/W] 0.35 0.3 0.2 0.16 0.11 Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] 720/660 1620/1500 3280/3000 8320/7560 18000/16600 Minimum Power Factor (at Maximum load) (1) 0.5 0.5 0.5 0.5 0.5 HP Rating UL 508/IEC60947 [-10 Option][HP (KW)]: 120 VAC 0.5 (0.37) 1 (0.74) 2 (1.5) 3 (2.24) 5 (3.37) HP Rating UL 508/IEC60947 [-10 Option][[HP (KW)]: 240 VAC 1.5 (1.1) 3 (2.2) 5 (3.73) 7.5 (5.6) 10 (7.5) HP Rating UL 508/IEC60947 [-10 Option][[HP (KW)]: 480 VAC 3 (2.24) 5 (3.7) 7.5 (5.6) 10 (7.4) 15 (11.2) HP Rating UL 508/IEC60947 [HP (KW)]: 120 VAC 0.5 (0.37) 0.75 (0.56) 1 (0.74) 2 (1.5) 3 (2.2) HP Rating UL 508/IEC60947 [HP (KW)]: 240 VAC 1.5 (1.1) 2 (1.5) 3 (2.2) 5 (3.73) 7.5 (5.6) HP Rating UL 508/IEC60947 [HP (KW)]: 480 VAC 3 (2.24) 5 (3.7) 7.5 (5.6) 10 (7.4) 15 (11.2) (1) INPUT SPECIFICATIONS Description CWD CWA CWAxxxxE CWU Control Voltage Range 4-32 VDC 90-280 VAC (4) 18-36 VAC 20-48 VDC/ 20-280 VAC Maximum Reverse Voltage -32 VDC - - - Minimum Turn-On Voltage 4 VDC (5) 90 VAC 18 VAC 19 VDC/VAC Minimum Turn-Off Voltage 1 VDC 10 VAC 4 VAC 5 VDC/VAC Minimum Input Current (for on-state) 10 mA 6 mA 13 mA 7/13 mA Maximum Input Current 15 mA 10 mA 15 mA 11/9 mA Nominal Input Impedance Current Regulated Current Regulated Current Regulated Current Regulated Maximum Turn-On Time [msec] 1/2 Cycle (6) 20 20 20 Maximum Turn-Off Time [msec] 1/2 Cycle 30 30 30 FDE-07-01 REV. A Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet (1) GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms 9 Minimum Insulation Resistance (@ 500 VDC) 10 Ohms Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range (7) -40 to 80 °C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 2.88 oz (81.53 g) Housing Material UL94 V-0 Baseplate Material Aluminum Input Terminal Screw Torque Range (in-lbs/Nm) 13-15 /1.5-1.7 Load Terminal Screw Torque Range (in-lbs/Nm) 18-20 / 2-2.2 SSR Mounting Screw Torque Range (in-lbs/Nm) 18-20 / 2-2.2 Input/Output Terminal Screw Thread Size #6-32 UNC / #8-32 UNC Humidity per IEC60068-2-78 93% non-condensing LED Input Status Indicator Green 11,641,553 hours (1,328 years) MTBF (Mean Time Between Failures) at 40°C ambient temperature (8) 7,210,376 hours (823 years) MTBF (Mean Time Between Failures) at 60°C ambient temperature (8) WIRING DIAGRAM AC V Load (9) Input Current vs Input Voltage Standard Regulated DC Input Recommended Wire Sizes 14 1 ( ) 2 ( ) Wire Size Wire Pull-Out 12 Terminals (Solid / Stranded) Strength (lbs)[N] 10 2 24 AWG (0.2 mm ) / 0.2 [minimum] 10 [44.5] 8 2 1 OUTPUT Input S OL I D S T A T E R EL A Y 2 6 2 x 12 AWG (3.3 mm ) / 3.3 [maximum] 90 [400] 4 2 20 AWG (0.5 mm ) / 0.518 [minimum] 4 30 [133] INPUT 3 2 Output 2 2 x 10 AWG (5.3 mm ) / 5.3 110 [490] 0 0 5 10 15 20 25 30 35 2 2 x 8 AWG (8.4 mm ) / 8.4 [maximum] 90 [400] DC Input Voltage 4 (– / ) 3 (+ / ) Input Current vs Input Voltage Standar Regulated AC Input 7 6 5 EQUIVALENT CIRCUIT BLOCK DIAGRAMS 4 CWD Series DC Control 3 -DC 4 2 1 AC 1 Trigger (10) 0 Circuit 0 50 100 150 200 250 300 AC Input Voltage +DC 3 2 AC Current Limiter Input Current vs Input Voltage Regulated AC Input Option “E” 16 CWA/CWU Series AC Control 14 Current 12 Limiter 10 AC/-DC 4 1 AC 8 AC/DC Trigger (10) 6 Converter Circuit 4 2 2 AC AC/+DC 3 0 0 5 10 15 20 25 30 35 AC Input Voltage Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. INPUT INPUT OUTPUT OUTPUT Input Current (mA) Input Current (mA) Input Current (mA) Panel Mount Datasheet (1) MECHANICAL SPECIFICATIONS Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Screw Termination, IP20 Screw Termination 1.1 1.1 Mounting [27.9] Mounting [27.9] 0.94 Hole/Slot 0.49 Hole/Slot [24.00] 0.49 0.19 [4.9] [12.4] 0.19 [4.9] [12.4] DIA. DIA. 2 1 OUTPUT 1.88 2.25 1.7 2.32 2.25 1.88 S O L I D S T A T E R E L A Y 1.7 [47.6] [57.3] [43.2] [58.8] INPUT [57.3] [47.6] [43.2] 4 3 1.0 1.0 1.22 1.0 [25.4] [25.4] [30.9] [25.4] 1.75 1.75 1.75 [44.5] [44.5] [44.5] GENERAL NOTES (1) “P” option output will self trigger between 900-1200 Vpk. Power factor 0.7 or higher, not suitable for capacitive loads. (2) All parameters at 25°C unless otherwise specified. (3) Heat sinking required, see derating curves (4) For ambient temperature above 40°C the maximum control voltage must not exceed 250VAC. (5) Increase minimum voltage by 1V for operations from -20 to -40°C. (6) Turn-on time for Instantaneous turn-on versions is 0.1 msec and 7msec for CWU models. (7) AC input models operating range is -20 to 80 °C. (8) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report). (9) Load can be wired to either SSR output terminal 1 or 2. (10) Select P option for overvoltage protection. (11) For single surge pulse Tc=25°C; Tj=125°C. For AC Output SSRs, AC Rms value of surge current equals the peak value divided by √2 (1.414). For additional information or specific questions, contact Crydom Technical Support. Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet SURGE CURRENT INFORMATION Single Pulse (11) CWxxx10 CWxxx25 400 600 350 500 300 400 250 200 300 150 200 100 100 50 0 0 0.01 0.1 1 10 0.01 0.1 1 10 CWxxx50 CWxxx90 1500 800 700 1200 600 500 900 400 600 300 200 300 100 0 0 0.01 0.1 1 10 0.01 0.1 1 10 CWxxx125 2000 1500 1000 500 0 0.01 0.1 1 10 Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Surge Duration (sec) Surge Duration (sec) Surge Duration (sec) Surge Duration (sec) Surge Duration (sec) Surge Current (Amp) AC Peak Surge Current (Amp) AC Peak Surge Current (Amp) AC Peak Surge Current (Amp) AC Peak Surge Current (Amp) AC Peak Panel Mount Datasheet THERMAL DERATE INFORMATION (i) SSR metal base plate acting as heat sink, it must be exposed to free ambient air. CWxxx10 CWxxx25 5°C/W No Heat Sink (i) 2°C/W 3°C/W 5°C/W 10 25 8 20 6 15 4 10 2 5 0 0 20 30 40 50 60 70 80 20 30 40 50 60 70 80 Ambient Temperature (ºC) Ambient Temperature (ºC) CWxxx50 CWxxx90 1°C/W 1.5°C/W 2°C/W 0.5°C/W 0.7°C/W 1°C/W 1.5°C/W 50 90 75 40 60 30 45 20 30 10 15 0 0 20 30 40 50 60 70 80 20 30 40 50 60 70 80 Ambient Temperature (ºC) Ambient Temperature (ºC) CWxxx125 0.36°C/W 0.5°C/W 0.7°C/W 1°C/W 120 100 80 60 40 20 0 20 30 40 50 60 70 80 Ambient Temperature (ºC) Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Load Current (Amps) Load Current (Amps) Load Current (Amps) Load Current (Amps) Load Current (Amps) Panel Mount Datasheet AGENCY APPROVALS EN60950-1: Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: Certified according to EN 62314:2006 IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3 IEC 61000-4-5 Electrical Surges Level 3 LR 38595 E79183 ACCESORIES Recommended Accessories New Accessory! Hardware Kits Hardware Kit Cover Hardware Heat Sink Thermal Resistance Lug Terminal Thermal Pad Part number: HK4 Kit Part No. [ºC/W] Bag with 2 square brass accessories and 2 5.0 KS101 HK1 HS501DR TRM1 HSP-1 screw 8-32 x 5/8 for output. Used to mount TMR1 lug terminals. 3.0 HS301 / HS301DR HK4 TRM6 HSP-2 2.5 HS251 2.0 HS201 / HS201DR 2.0 HS202 / HS202DR 1.7 HS172 1.5 HS151 / HS151DR 1.2 HS122 / HS122DR 1.0 HS103 / HS103DR 1.0 HS101 0.7 HS073 0.7 HS072 0.5 HS053 0.36 HS033 0.25 HS023 Rev. 092217 ECN 20325 Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF RIESGO DE RISQUE DE GEFAHR EINES RISCHIO DI 存在电击、 ELECTRIC DESCARGA DESCHARGE ELEKTRISCHE SCOSSA 爆炸或电弧 SHOCK, ELECTRICA O ELECTRIQUE N SCHLAGES ELETTRICA O 闪烁危险 EXPLOSION, EXPLOSION. OU EXPLOSION ODER EINER DELL’ESPLOSIONE. OR ARC FLASH. EXPLOSION. • Eteindre • 在操作此设 • Desconectar • Spenga tutta • Disconnect all • Stellen Sie toutes les todos los l'alimentazione 备之前请先 power before jeglichen sources suministros de che fornisce 关闭电源。 installing or Strom ab, der d'énergie de energia a este questa working with dieses Gerät cet appareil equipo antes apparecchiatura 若不遵守这些说明, this equipment. versorgt, bevor de trabajar avant de prima di lavorare 可能会导致严重的 Sie an dem con este equipo. travailler a questa • Verify all Gerät Arbeiten 人身伤害甚至死亡。 dessus de cet apparecchiatura connections • Verificar todas durchführen appareil and replace all las conexiones • Verificare tutti • Vor dem covers before y colocar todas i collegamenti • Vérifier tous Drehen auf turning on e sostituire las tapas antes connections, et Energie alle power. de energizer remettre tous tutte le coperture Anschlüsse prima el equipo. couverts en überprüfen Failure to follow dell’accensione olace avant de und alle these El mettre sous Abdeckungen instructions will L'omissione di incumplimiento ersetzen. De non-suivi de result in death queste istruzioni de estas ces instructions or serious injury. provocherà la Unterlassung instrucciones provoquera la morte o dieser puede provocar mort ou des lesioni serie Anweisungen la muerte o lésions sérieuses können zum lesiones serias. sérieuses. Tode oder zu schweren Verletzungen führen. WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告 RISQUE DE DOMMAGE MATERIEL ET DE GEFAHR VON MATERIALSCHÄDEN UND RISK OF MATERIAL DAMAGE AND HOT SURCHAUFFE DU BOITIER GEHÄUSEERHITZUNG ENCLOSURE • Les panneaux latéraux du produit peuvent être • Die Seitenwände können heiß sein. Lassen Sie • The product's side panels may be hot, allow chauds. Laisser le produit refroidir avant de le das Produkt abkühlen, bevor Sie es berühren. the product to cool before touching. toucher. • Beachten Sie die Montageanweisungen, • Follow proper mounting instructions including • Respecter les consignes de montage, et • Führen Sie keine Flüssigkeiten oder torque values. notamment les couples de serrage. Fremdkörper in das Produkt ein. • Do not allow liquids or foreign objects to enter • Ne pas laisser pénétrer de liquide ni de corps this product. étrangers à l'intérieur du produit. Le non-respect de cette directive peut entraîner, Die Nichtbeachtung dieser Anweisung kann Failure to follow these instructions can result in des lésions corporelles graves ou des Körperverletzung oder Materialschäden serious injury, or equipment damage. dommages matériels. zur Folge haben. RIESGO DE DAÑOS MATERIALES Y DE RISCHIO DI DANNI MATERIALI E D'INVOLUCRO 材料损坏和高温外壳的危险性 SOBRECALENTAMIENTO DE LA UNIDAD CALDO • 产品的一侧面板可能很热,在其冷却前请 • Los paneles laterales del producto pueden • I pannelli laterali dell'apparecchio possono 不要触碰。 estar calientes. Esperar que el producto se scottare; lasciar quindi raffreddare il prodotto • 遵照正确的安装说明,包括扭矩值。 enfríe antes de tocarlo. prima di toccarlo. • 请勿让液体及其他异物进入本产品。 • Respetar las instrucciones de montaje, y en • Seguire le istruzioni di montaggio corrette. particular los pares de apretado. • Non far entrare liquidi o oggetti estranei in questo • No dejar que penetren líquidos o cuerpos apparecchio. extraños en el producto. La mancata osservanza di questa precauzione può 如不能正确执行这些操作说明, Si no se respetan estas precauciones pueden causare gravi rischi per l'incolumità personale o 极有可能造成严重人体伤害或者设备的损坏。 producirse graves lesiones, daños materiales. danni alle apparecchiature. Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet ANNEX - ENVIRONMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Toxic or hazardous Substance and Elements Name Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated Chromium biphenyls diphenyl ethers (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) Semiconductor die Solder 附件 - 环保信息 此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求。 部件 有毒有害物质或元素 名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) 半导体芯片 焊接点 50 Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice.
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the CWD4825?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers



What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods