CRYDOM MCTC2425JLA
Specifications
Manufacturer
Crydom
Manufacturers Part #
MCTC2425JLA
Industry Aliases
MCTC2425JLA
Sub-Category
Solid State Relays
Factory Pack Quantity
5
Datasheet
Extracted Text
Control Relays DataSheet MCTC Series • Microprocessor based temperature controller / SSR • Ratings from 25A to 90A @ 48-530 VAC • Direct J or K thermocouple input • Voltage or current controlled setpoint • Separate output enable / disable control • Open thermocouple protection • LED status indicators • Optional 5Vdc output voltage for setpoint voltage reference • For use with resistive loads only PRODUCT SELECTION Control Voltage 25 A 50 A 90 A 280 VAC MCTC2425 MCTC2450 MCTC2490 480 VAC MCTC4825 MCTC4850 MCTC4890 AVAILABLE OPTIONS Setpoint Input A: 0-5 VDC B: 0.7 VDC Line Voltage Termocouple Type C: 0-10 VDC 24: 24-280 Vrms J: Type J Series D: 4-20 mA 48: 48-530 Vrms K: Type K TC MC 24 25 U J U L A E Aditional Features Rated Current Temperature Range E: 5Vdc Output Product Type 25: 25 Amps L: 100˚F to 500˚F, Valid only with Setpoint input A TC: Temperature 50: 50 Amps 38˚C to 260˚C (0-5Vdc) 90: 90 Amps Controller H: 300˚F to 700˚F, 149˚C to 371˚C VH: 500˚F to 900˚F, Required for valid part number 260˚C to 482˚C EH: 700˚F to 1100˚F, 371˚C to 593˚C R: +100˚F to -100˚F, +38˚C to -73˚C OUTPUT SPECIFICATIONS (voltage) Description 240 VAC 480 VAC Operating Voltage (47-63Hz) [VRMS] 24-280 48-530 Transient Overvoltage [Vpk] 600 1200 Maximum Off-State Leakage Current @ Rated Voltage [mARMS] 7 12 Minimum Off-State dV/dt @ Maximum Rated Voltage [V/μsec] 200 200 OUTPUT SPECIFICATIONS (current) Description 25 A 50 A 90 A Maximum Load Current [Arms] 25 50 90 150 150 Minimum Load Current [mArms] 150 Maximum Surge Current (16.6ms) [Apk] 250 625 1200 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 Thermal Resistance Junction to Case (Rjc) [°C/W] 1.02 0.63 0.28 2 2 Maximum l t for Fusing (8.3 msec) [A sec] 260 1620 6000 Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5 Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Obsolete Control Relays DataSheet (2) INPUT SPECIFICATIONS Description DC Control P1 Voltage Supply Range (VDC) 8-32 P1 Supply Current Range [mA] (2) 28-30 Control Nominal Input Impedance [Ohms] [P3] 30K Control Must Operate Voltage "On"[VDC][P3] 5-32 Control Must Release Voltage "Off" [VDC][P3] 0-4 Control Input Current [mA][P3] 0-1.25 PLVI Range Option A [VDC][P4] (3) 0.8-5 PLVI Range Option B [VDC][P4] (3) 1-7 PLVI Range Option C [VDC][P4] (3) 2-10 PLVI Range Option D [ma][P4] (3) 4-20 Nominal Input Impedance Option A,B,C[ohms][P4] 20K Nominal Input Impedance Option D [ohms][P4] 220 Output Voltage [VDC][P5] 4-75-5.25 Maximum Output Current [mA][P5] 10 GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) 4000 VRMS 9 Minimum Insulation Resistance (@ 500 VDC) 10 Ohms Maximum Capacitance, Input/Output 10 pF Ambient Operating Temperature Range -20 to 80 °C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 3.0 oz (86.5g) Thermally conductive Epoxy Encapsulation Terminals-Power Screws and Saddle Clamps Furnished, Unmounted Terminals-Control Barrier Strip Screw Terminals Recommended Terminal Screw Torque Range: 8-32 Screws-20 in. lbs. (Screws dry without grase) OUTPUT STATUS FUNCTIONS Description GREEN LED (setpoint) RED LED (output) Initial Logic Supply On Flash Once Flash Once Operating (to 85 % of set point) Off On Off Variable Flashing Approaching Setpoint At Setpoint (± 5%) On Slow Flashing Over Setpoint (>5%) (4) Flashing Off Short-Cycle Timing ("R" suffix only) Flash 2x Intermittently Off Off Open Thermocouple Flash 3x Intermittently Off Off GENERAL NOTES (1) Voltages are reference to GND (Ground = 0 VDC) P2 (2) Input current may vary with –E option. (3) PLVI voltage can go up to max. supply voltage without damage. (4) Below Setpoint for “R” suffix Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Obsolete Control Relays DataSheet MECHANICAL SPECIFICATIONS 1.10 [27.9] ~ AC 8-32 TERMINAL MOUTING .45 (2 PLACES) LOAD HOLE/SLOT [11.4] 0.192 (4.3) DIA. OUTPUT OUTPUT AC2 AC1 2.30 1.87 [58.4] [47.5] OUTPUT SET OUTPUT SET STATUS TEMP P5 OPTIONAL P5 OPTIONAL STATUS TEMP P4 J TYPE P4 0-5V, 0-V, 0-10V, 4-20mA P3 P3 ON/OFF Control P2 P2 Ground (-) P1 P1 ON/OFF Control .78 MOUTING Note: P2 is also 4ma return [19.8] 1.80 HOLE/SLOT P5 Terminal only comes with -E Option [45.7] 0.192 (4.3) DIA. WIRING DIAGRAM Wiring Example Wiring Example Option-E (for Options A, B, or C using an external potentiometer) 5 Vdc + 10k to 50k pot for Terminal P5 50k Options A, B or C potentiometer Setpoint Adjust Setpoint Adjust Option-E Terminal P4 Enable Enable DC DC GND GND Supply Supply +Vdc Terminal P1 Terminal P1 +Vdc THERMAL DERATE INFORMATION 25 A 50 A 90 A 95 30 60 95 120 90 .2˚C/W 1˚C/W 1˚C/W .5˚C/W .5˚C/W 25 100 .4˚C/W 3˚C/W 100 1.5˚C/W 20 2˚C/W 40 100 80 2˚C/W 1˚C/W 15 110 110 110 10 20 40 NO HEATSINK 120 5 120 120 NO HEATSINK 0 0 0 0 5 10 15 20 25 20 40 60 80 0 10 20 30 40 50 20 40 60 80 20 40 60 80 0 20 40 60 80 Load Current [Arms] Max Ambient Temp. [ºC] Load Current [Arms] Max Ambient Temp. [ºC] Load Current [Arms] Max Ambient Temp. [ºC] Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Obsolete Power Dissipation Base Plate Temp [˚C] Power Dissipation Base Plate Temp [˚C] Power Dissipation Base Plate Temp [˚C] Control Relays DataSheet TEMPERATURE VS SETPOINT INPUT P4 0-5 Vdc Option A 0-7 Vdc Option B 1100 1100 900 900 700 700 500 500 300 300 100 100 0 0 0 1 2 4 5 6 0 1 2 4 5 6 7 3 3 8 Input Voltage P4 Input Voltage P4 0-10 Vdc Option C 4-20mA Vdc Option D 1100 1100 900 900 700 700 500 500 300 300 100 100 0 0 0 2 4 6 8 10 0 2 4 6 8 10 12 14 16 18 20 Input Voltage P4 Input Voltage P4 -100˚F to 100˚F Vdc Option R -100˚F to 100˚F Vdc Option R 100 100 80 80 60 60 40 40 20 20 0 0 -20 -20 -40 -40 -60 -60 -80 -80 -100 -100 0 1 2 3 4 5 7 8 9 10 11 0 2 4 6 8 10 12 14 16 18 20 6 12 Input Voltage P4 Input Voltage P4 AGENCY APPROVALS AGENCY APPROVALS UL E116949 Rev. 032111 Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Option EH Option VH Option H Option L Option EH Option VH Option H Option L Option EH Option VH Option H Option L Option EH Option VH Option H Option L Obsolete Temperature ˚F Temperature ˚F Temperature ˚F Temperature ˚F Temperature ˚F Temperature ˚F Control Relays DataSheet DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF RIESGO DE RISQUE DE GEFAHR EINES RISCHIO DI 存在电击、 ELECTRIC DESCARGA DESCHARGE ELEKTRISCHE SCOSSA 爆炸或电弧 SHOCK, ELECTRICA O ELECTRIQUE N SCHLAGES ELETTRICA O 闪烁危险 EXPLOSION, EXPLOSION. OU EXPLOSION ODER EINER DELL’ESPLOSIONE. OR ARC FLASH. EXPLOSION. • Eteindre • 在操作此设 • Desconectar • Spenga tutta • Disconnect all • Stellen Sie toutes les todos los l'alimentazione 备之前请先 power before jeglichen sources suministros de che fornisce 关闭电源。 installing or Strom ab, der d'énergie de energia a este questa working with dieses Gerät cet appareil equipo antes apparecchiatura 若不遵守这些说明, this equipment. versorgt, bevor de trabajar avant de prima di lavorare 可能会导致严重的 Sie an dem con este equipo. travailler a questa • Verify all Gerät Arbeiten 人身伤害甚至死亡。 dessus de cet apparecchiatura connections • Verificar todas durchführen appareil and replace all las conexiones • Verificare tutti • Vor dem covers before y colocar todas i collegamenti • Vérifier tous Drehen auf turning on e sostituire las tapas antes connections, et Energie alle power. de energizer remettre tous tutte le coperture Anschlüsse prima el equipo. couverts en überprüfen Failure to follow dell’accensione olace avant de und alle these El mettre sous Abdeckungen instructions will L'omissione di incumplimiento ersetzen. De non-suivi de result in death queste istruzioni de estas ces instructions or serious injury. provocherà la Unterlassung instrucciones provoquera la morte o dieser puede provocar mort ou des lesioni serie Anweisungen la muerte o lésions sérieuses können zum lesiones serias. sérieuses. Tode oder zu schweren Verletzungen führen. WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告 RISQUE DE DOMMAGE MATERIEL ET DE GEFAHR VON MATERIALSCHÄDEN UND RISK OF MATERIAL DAMAGE AND HOT SURCHAUFFE DU BOITIER GEHÄUSEERHITZUNG ENCLOSURE • Les panneaux latéraux du produit peuvent être • Die Seitenwände können heiß sein. Lassen Sie • The product's side panels may be hot, allow chauds. Laisser le produit refroidir avant de le das Produkt abkühlen, bevor Sie es berühren. the product to cool before touching. toucher. • Beachten Sie die Montageanweisungen, • Follow proper mounting instructions including • Respecter les consignes de montage, et • Führen Sie keine Flüssigkeiten oder torque values. notamment les couples de serrage. Fremdkörper in das Produkt ein. • Do not allow liquids or foreign objects to enter • Ne pas laisser pénétrer de liquide ni de corps this product. étrangers à l'intérieur du produit. Le non-respect de cette directive peut entraîner, Die Nichtbeachtung dieser Anweisung kann Failure to follow these instructions can result in des lésions corporelles graves ou des Körperverletzung oder Materialschäden serious injury, or equipment damage. dommages matériels. zur Folge haben. RIESGO DE DAÑOS MATERIALES Y DE RISCHIO DI DANNI MATERIALI E D'INVOLUCRO 材料损坏和高温外壳的危险性 SOBRECALENTAMIENTO DE LA UNIDAD CALDO • 产品的一侧面板可能很热,在其冷却前请 • Los paneles laterales del producto pueden • I pannelli laterali dell'apparecchio possono 不要触碰。 estar calientes. Esperar que el producto se scottare; lasciar quindi raffreddare il prodotto • 遵照正确的安装说明,包括扭矩值。 enfríe antes de tocarlo. prima di toccarlo. • 请勿让液体及其他异物进入本产品。 • Respetar las instrucciones de montaje, y en • Seguire le istruzioni di montaggio corrette. particular los pares de apretado. • Non far entrare liquidi o oggetti estranei in questo • No dejar que penetren líquidos o cuerpos apparecchio. extraños en el producto. La mancata osservanza di questa precauzione può 如不能正确执行这些操作说明, Si no se respetan estas precauciones pueden causare gravi rischi per l'incolumità personale o 极有可能造成严重人体伤害或者设备的损坏。 producirse graves lesiones, daños materiales. danni alle apparecchiature. Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Obsolete Control Relays DataSheet ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Toxic or hazardous Substance and Elements Name Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated Chromium biphenyls diphenyl ethers (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) Semiconductor die Solder 附件 - 环保信息 此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求。 部件 有毒有害物质或元素 名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) 半导体芯片 焊接点 50 Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Obsolete
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the MCTC2425JLA?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers



What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods