EATON BUSSMANN MS60

Description

Power Module Panel All-In-One Module
MS60

Part Number

MS60

Price

Request Quote

Manufacturer

EATON BUSSMANN

Lead Time

Request Quote

Category

Thermal Management »  Misc Products

Specifications

Manufacturer

Eaton Bussmann

Manufacturers Part #

MS60

Sub-Categories

Miscellaneous Tools and Supplies

Factory Pack Quantity

1

Datasheet

pdf file

fc0c02f2-6d4d-4174-81aa-8f7ae9c74221.pdf

318 KiB

Extracted Text

® ™ Cooper Bussmann Quik-Spec Power Module™ Panel PMP All-In-One Module Power Module Panel R Ra at tiin ng gs s ((A Am mp ps s)) ((P Pa an ne ellb bo oa ar rd d B Bu us s)) C Ca at ta allo og g N Nu um mb be er r 400 PMP-400 600 PMP-600 800 PMP-800 Panel Components V Vo ollt ta ag ge e/ /A Am mp p R Ra at tiin ng gs s C Co om mp po on ne en nt t 1 1 ((R Re eq qu uiir re ed d)) Control power transformer (CPT) Std. 100VA with PRI & 208Vac SEC Fuse (120V secondary) 240Vac 480Vac 600Vac C Co om mp po on ne en nt t 2 2 ((R Re eq qu uiir re ed d)) Fire safety interface Relay (3PDT, 10 amp, 120V) 24Vdc Coil 120Vac Coil C Co om mp po on ne en nt t 3 3 ((O Op pt tiio on na all)) Key to test switch 120Vac C Co om mp po on ne en nt t 4 4 ((O Op pt tiio on na all)) Pilot light – “ON” Red Green White C Co om mp po on ne en nt t 5 5 ((O Op pt tiio on na all)) 2 Isolated neutral lug (full capacity) 30-60A 100A Features and Options 200A • 400-800 amp Bus MLO and/or Main Switch* C Co om mp po on ne en nt t 6 6 ((R Re eq qu uiir re ed d)) 200,000 amp RMS Short-Circuit Current Rating Mechanically interlocked auxiliary contact for hydraulic 1 NO & 1 NC 1 Feeder switches 30-200 amp, 600Vac with Class J Clips elevators with battery back-up (5 amp 120Vac rated) Copper Bus C Co om mp po on ne en nt t 7 7 ((O Op pt tiio on na all)) Contact Cooper Bussmann for applications greater than 800 amps * Fire alarm voltage monitoring relay Single-Pole (To monitor shunt trip voltage) Optional Features Control power transformer with fuses and blocks Fire safety interface relay Key to test switch Pilot light – “ON” 2 Isolated neutral lug Mechanically interlocked auxiliary contact for hydraulic elevators with battery backup (5 amp 120Vac rated) Fire Alarm Voltage Monitoring Relay (to monitor Shunt Trip Voltage) NEMA 3R enclosures available (consult factory) Phase failure and undervoltage relay available (consult factory) ® For added safety, use the Cooper Bussmann SAMI™ fuse covers to 3 improve maintenance personnel protection [OSHA 1910.335(A)(2)(ii)] Agency Information UL 98 Enclosed and Dead-Front Switches 1 Class J fuses not included. 2 Oversized 200% rated neutral option available where required by excessive non-linear loads. 3 Through 100A. 0608 BU-SB08354 Page 1 of 6 Data Sheet 1146 Module Switch Options, X Dimensions and Lug Data S Sw wiit tc ch h C Co on nd du uc ct to or rs s A Am mp p R Ra at tiin ng g M Mo ou un nt tiin ng g “ “X X” ” U Un niit ts s p pe er r P Ph ha as se e T Te er rm miin na all W Wiir re e R Ra an ng ge e 1 1 6 60 00 0 V Vo ollt t – – B Br ra an nc ch h S Sw wiit tc ch h U Un niit t 30 Horizontal 6X 1 #14 - 1/0 Al or Cu 30-30 Horizontal 6X 1 #14 - 1/0 Al or Cu 60 Horizontal 6X 1 #14 - 1/0 Al or Cu 60-60 Horizontal 6X 1 #14 - 1/0 Al or Cu 100 Horizontal 6X 1 #14 - 1/0 Al or Cu 100-100 Horizontal 6X 1 #14 - 1/0 Al or Cu 200 Horizontal 6X 1 #4 - 300 kcmil Al or Cu 200-200 Horizontal 6X 1 #4 - 300 kcmil Al or Cu 6 60 00 0 V Vo ollt t - - M Ma aiin n S Sw wiit tc ch h 400 Horizontal 1X 1 or 2 (1) 250 - 750kcmil (2) 3/0 - 250 kcmil Al or Cu 600 Horizontal 3X 1 or 2 (1) #4 - 600kcmil (2) 1/0 - 250 kcmil Al or Cu 800 Vertical 9X 1 or 2 (1) 250 - 750kcmil (2) 3/0 - 250 kcmil Al or Cu 1 May mix switch amps 30 to 200A: 30/60, 30/100, 30/200, etc. Top Main Lugs Terminal Data Standard Mechanical Lugs 2 2 M Ma aiin n A Am mp p C Co on nd du uc ct to or rs s M Miin n.. W Wiir re e B Be en nd diin ng g S Sp pa ac ce e ((iin nc ch he es s)) A R Ra at tiin ng g p pe er r P Ph ha as se e T Te er rm miin na all W Wiir re e R Ra an ng ge e A A B B C C 1 3/0 - 750 kcmil Al or Cu 400 14.00 10.625 7.00 2 3/0 - 250 kcmil Al or Cu 600 2 #4 - 500 kcmil Al or Cu 14.00 10.625 7.00 800 4 #2 - 600kcmil Al or Cu 18.00 10.625 7.00 CC 2 Wire bending space can vary per local codes and standards requirements. B Standard Panel Box Dimension with Available Panel Space 40" D Diim me en ns siio on ns s ((IIn nc ch he es s)) X 3 3 A Am mp ps s H H x x W W x x D D “ “X X” ” U Un niit ts s MLO Incoming * - Top or Bottom 400 57 x 40 x 10.4 18X Accessory Control Enclosure 6 600 73.5 x 44 x 10.4 30X (ACE)** 800 90 x 44 x 10.4 40X Branch 30A 30A 6 3 Where X Units exceed panel space, use feed-through lugs and second enclosure. Unit 6 60A 60A Mounting Feed-Through Lugs Space 6 100A 100A A Am mp ps s “ “X X” ” S Sp pa ac ce e 400 3X 6 200A 200A 600 3X 800 7X Feed-Through Lugs *** ® Wire bending space per NEC Table 312.6(A) * MLO standard, x-space does not affect brand x-space available. Accessory Control Enclosure ** One ACE unit per four shunt trip module switches. *** See table. A AC CE E 6 6X X Each ACE will handle individual control power transformers and isolation relays for up to four switch units. 0608 BU-SB08354 Page 2 of 6 Data Sheet 1146 Maximum Horsepower Rating of Switch F Fe ee ed de er r S Sw wiit tc ch h A Am mp p R Ra at tiin ng g M Ma aiin n S Sw wiit tc ch h A Am mp p R Ra at tiin ng g V Vo ollt ta ag ge e 3 30 0A A 6 60 0A A 1 10 00 0A A 2 20 00 0A A 4 40 00 0A A 6 60 00 0A A 8 80 00 0A A 208Vac-3P 5 10 15 40 75 100 150 240Vac-3P 5 10 20 40 75 125 150 480Vac-3P 10 25 40 75 150 250 350 600Vac-3P 15 30 50 100 200 350 450 ® Maximum horsepower rating of switch with Class J fuses, medium-duty inrush (NEC Code Max 175%). Recommended Hp to calculate fuse and switch size. The above table can be used for estimating switch size for motor loads based upon the motor horsepower. Size the switch so that the Class J, time-delay fuses ® are used at a minimum of 150% of motor full-load amps or next size up. For general applications, excluding wound rotor and DC motors, NEC 430.52 allows ® sizing at 175% of motor full-load amps or the next standard size per NEC 240.6. ® N No ot te e:: In sizing the fuses, the motor FLA, is per NEC Table 430.250, not per nameplate information. Inrush currents of motors may vary, consult motor manufacturer data for correct sizing. On elevator applications, motor load plus auxiliary loads need to be considered. Follow elevator manufacturer’s recommendation for correct fuse sizing. Standard Shunt Trip Ratings: 30-100A, 200A & 400-800A 1 1 V Vo ollt ta ag ge e M Ma ax x IIn nr ru us sh h M Ma ax x O On nt tiim me e M Mo om me en nt ta ar ry y IIn nr ru us sh h 120Vac, 60Hz 4 amps 1.5 cycles 140VA 1 Will handle up to 447VA inrush. 0608 BU-SB08354 Page 3 of 6 Data Sheet 1146 Typical Control with Wiring Options for Fire Safety Interface (Option R1) Legend N.O.F.A. Normally Open Fire Alarm contacts supplied from the fire alarm system to initiate the shunt trip. Shunt Trip Solenoid for remote trip of switch, which is activated by the closing of the fire alarm contacts or key test switch. Option R1 Fire Safety Interface Relay that is operated at 120Vac from secondary of transformer. No additional power needed. CR Control Relay used to isolate the N.O.F.A. contacts from the duty of the shunt trip. FR Fire Alarm Voltage Monitoring Relay used to monitor presence of voltage in switch from a remote location (Fire Alarm Control Panel). PL Pilot Light to visually indicate presence of voltage on outside of switch enclosure. CPT Control Power Transformer used to step down line voltage to 120VAC to power shunt trip coil. SW Aux. Normally closed contact when switch is closed. Opens as power switch opens. Key Test Key-to-Test switch used to operate shunt trip from the outside of switch enclosure. Can be used for trouble-shooting and inspection. M Me ec ch ha an niic ca alllly y IIn nt te er rllo oc ck ke ed d A Au ux xiilliia ar ry y C Co on nt ta ac ct t – Contact used to disconnect secondary source of power. � Terminal block connection point. � Pre-wired connection point. 0608 BU-SB08354 Page 4 of 6 Data Sheet 1146 Typical Control with Wiring Options for Fire Safety Interface (Option R2) Legend N.O.F.A. Normally Open Fire Alarm contacts supplied from the fire alarm system to initiate the shunt trip. Shunt Trip Solenoid for remote trip of switch, which is activated by the closing of the fire alarm contacts or key test switch. Option R2 Fire Safety Interface Relay that is operated at 24Vdc from fire alarm system. May require an additional power source to be needed. CR Control Relay used to isolate the N.O.F.A. contacts from the duty of the shunt trip. FR Fire Alarm Voltage Monitoring Relay used to monitor presence of voltage in switch from a remote location (i.e., Fire Alarm Control Panel). PL Pilot Light to visually indicate presence of voltage on outside of switch enclosure. CPT Control Power Transformer used to step down line voltage to 120Vac to power shunt trip coil. SW Aux. Normally closed contact when switch is closed. Opens as power switch opens. Key Test Key-to-Test switch used to operate shunt trip from the outside of switch enclosure. Can be used for trouble-shooting and inspection. M Me ec ch ha an niic ca alllly y IIn nt te er rllo oc ck ke ed d A Au ux xiilliia ar ry y C Co on nt ta ac ct t Contact used to disconnect secondary source of power. � Terminal block connection point. � Pre-wired connection point. 0608 BU-SB08354 Page 5 of 6 Data Sheet 1146 ® Section 16XXX – Cooper Bussmann Quik-Spec™ Power Module™ Panel Elevator – Computer Room – Emergency Systems Part 2 – Products Part 1 – General 2 2..0 01 1 M Ma an nu uf fa ac ct tu ur re er rs s ® ™ ™ A. Cooper Bussmann Quick-Spec Power Module Panel - PMP 1 1..0 01 1 D De es sc cr riip pt tiio on n A. Work of this section shall conform to the requirements of the 2 2..0 02 2 G Ge en ne er ra all C Co on nd diit tiio on ns s & & R Re eq qu uiir re em me en nt ts s Contract Documents. A. Provide Power Module Panel as shown on drawings. The Power Module Panel shall be constructed, listed and certified to the 1 1..0 02 2 S Se ec ct tiio on n IIn nc cllu ud de es s standards as listed in 1.05. The Power Module Panel shall be A. Provide Elevator Power Module Panel, fuses and accessories as ____ amp (MLO) (main switch) with copper bus (120/208V, required and specified on Contract Drawings to distribute electrical 3-phase, 3W or 4W) (277/480V, 3 phase, 3W or 4W). The Power power to all Elevators. Module Panel shall have individual horsepower-rated fusible feeder 1 1..0 03 3 R Re ella at te ed d S Sy ys st te em ms s switches with shunt trip capabilities (unless indicated). Feeder A. (Reference other sections of the specification which cover Elevator switches shall have ampere ratings based upon elevator installation) manufacturer requirements (if elevator load is present) and utilize Class J fuses (provided separately). All shunt trip fusible feeder 1 1..0 04 4 C Co od de es s switches shall have as an accessory a relay, control power A. All work shall be performed in accordance with the latest edition of transformer and other options (as listed below). The control power applicable standards, codes and laws. ® transformer shall be 100VA with primary and secondary fuses. The 1. NFPA-70 (NEC ) 2008 Edition- Section 620.51(A)-(C), 620.62, primary voltage rating shall be ____ volts with a 120 volt 620.91(C) secondary. The isolation relay shall be 3PDT, 10 amp, 120V. The 2. Canadian Electric Code Part 1 (2006 Edition) Section 38-051, coil of the isolation relay shall be ______ (120Vac or 24Vdc). A 38-062 normally open dry contact shall be provided by the Fire Alarm 3. ANSI/ASME A17.1-2007 - Section 2.8.3.3.2 Safety System to energize the isolation relay and activate the shunt 4. NFPA-72 2007 Edition - Section 6.16.4.4 trip solenoid (140VA inrush at 120V). (Note: If 24Vdc coil is A. Except as modified by governing codes, all equipment shall be selected, a separate 24Vdc source and contact may need to be manufactured in accordance with the latest applicable standards: provided in order to comply with the Fire Alarm Safety System 1. Panelboards, UL 67 and CSA - C22.2 No. 29 power requirements.) 2. Switchboards, UL 891 and CSA – C22.2 No. 31 Additional accessories provided for each fusible shunt trip switch 1 1..0 06 6 S Su ub bs st tiit tu ut tiio on ns s include: A. Substitutions shall comply with the requirements of the General _____ Key to Test Switch Conditions and General Requirements. The names of manufacturers _____ “On” Pilot Light (Green, Red or White) and model numbers have been used to establish types of _____ 1P NC Mechanical Interlock (required for hydraulic elevators equipment and standards of quality. A submittal shall contain with automatic recall) ` sufficient information to prove compliance with Contract _____ Fire Alarm Voltage Monitoring Relay (Needed to comply with Documents. This includes compliance with all pertinent sections of NFPA 72) codes and standards as specified above. The module shall have been successfully tested to a short- ® ® circuit rating with Cooper Bussmann Low-Peak Class J 1 1..0 07 7 S Su ub bm miit tt ta alls s fuses at 200,000 amps RMS Symmetrical. All switches shall A. Submit shop drawings and product data under the provisions of the General Conditions. have shunt trip capabilities at 120Vac from remote fire safety signal. Branch feeders shall be selectively coordinated and B. Product Data: Provide manufacturer’s catalog information showing fed with an upstream supply overcurrent protective device at dimensions, configurations, and methods of mounting and a minimum of 2:1 size ratio utilizing Low-Peak (Class J, RK1, installation. or L) fuses. C. Submit listing of all types, sizes and quantity of fuses which will be installed including the location of each. Part 3 – Execution D. Spare fuses shall be supplied as required by (reference fuse 3 3..0 01 1 IIn ns st ta alllla at tiio on n specification section). A. All material installation shall be in accordance with manufacturers recommendations and the provisions of applicable codes. B. Fuses shall not be installed until equipment is ready to be energized. The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 0608 BU-SB08354 Page 6 of 6 Data Sheet 1146

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the MS60?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Camaster HRC Fuse Holders 20BS

product

Pull Out With GFCI B222-60FGF

product

60A, Pull Out W/ 1/2in Cable Whip B222-60NF12W

product

60A, Pull Out W/ 3/4in Cable Whip B222-60NF34W

product

Cartridge Fuses 250Vac 50A Fast Acting BK/AGC-50

product

Battery Disconnect Switches Surge Protectors And Computer Memory BP/BMS-1