Electronics Finder chervon right Manufacturers chervon right G chervon right GE CRITICAL POWER chervon right CCR0512FPXXXZ01A
About product Specifications Datasheet FAQ

GE CRITICAL POWER CCR0512FPXXXZ01A

Image of GE CRITICAL POWER CCR0512FPXXXZ01A

Description

500 W, Double Output, 12 V@42 A | 3.3 V@2 A Industrial Enclosed AC-DC Power Supply

Part Number

CCR0512FPXXXZ01A

Price

Request Quote

Manufacturer

GE CRITICAL POWER

Lead Time

Request Quote

Category

Circuit Protection »  AC-DC Power Supply

Specifications

Manufacturer

GE Critical Power

Manufacturers Part #

CCR0512FPXXXZ01A

Industry Aliases

CCR0512FPXXXZ01A

Brand

GE Critical Power

Series

CCR0512FP

Factory Pack Quantity

5

Application

General Purpose

Convection Rating

500 W

Cooling Method

Conduction

Dimensions

10.40 x 4.39 x 0.89"

Efficiency

91.4%

Environmental Conditions

General Purpose

Industry

Industrial

Isolation

Class I

Mechanical Style

Open / Enclosed Frame

Number of Outputs

2

Operating Temperature

-20 to +85°C (baseplate)

Output Amps 1

42 A

Output Amps 2

2 A

Output Voltage V1 Nominal

12 V

Output Voltage V2 Nominal

3.3 V

Package Type

Enclosed

Power

500 W

Subcategory

AC-DC Power Supply

Datasheet

pdf file

CCR0512FP.pdf

1972 KiB

Extracted Text

GE CRITICAL POWER Data Sheet GE CCR0512FP SERIES 500 Watt Conduction-Cooled Power Supply CCR0512FP Power Supply Measures: 8.79 x 3.35 x 0.877” 90 - 264V Input; 12V , 500W Output ac dc Features • Conduction cooling for fan less operation • Compact 0.5U Profile • Overall Dimensions: 0.877 in. x 3.35 in. x 8.790 in. • 12V , 500W Output dc • 10.8 to 13.2V Output Voltage Programmability dc • Universal AC input with Active PFC • Hot Plugability • Redundant Parallel Operation • Active Load Sharing (Single Wire) ^ • Analog, I²C or PMBus means of control and monitoring • Remote On/Off • Remote Sense (up to 0.25V of total compensation) • No Minimum Load Requirements Applications • Three visual LED Indicators; Input, Output and Fault status • Test Equipment • 3.3V or 5.0 V 2A Standby Output dc dc • Network Support Equipment * † • UL Recognized to UL60950-1, CAN/CSA C22.2 • Storage Area Networks (SAN) ‡ No.60950-1, and EN60950-1(VDE 0805-1) Licensed • Network Attached Storage (NAS) § • CE mark meets 2006/95/EC directive • Servers ** • ISO 9001 and ISO 14001 certified manufacturing facility • Compliant to RoHS EU Directive 2011/65/EU Description The CCR0512FP power supply is a universal ac input, 12Vdc, 500W output fan-less conduction cooled, 0.5U thick product designed for environments, where conduction or system airflow is available for cooling. The 0.5U form factor makes locating the supply very flexible and space efficient. The supply includes capability for hot plug and redundant load sharing applications. Standard features include remote sense, output voltage programmability, active load sharing, status LEDs, 3.3V or 5.0V standby output, dc dc 2 and analog, I C and PMBus control and communication interfaces. ^PMBus name and logo are registered trademarks of SMIF, Inc. * UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Association. ‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V § This product is intended for integration into end-user equipment. All of the required procedures of end-use equipment should be followed. ** ISO is a registered trademark of the International Organization of Standards August 12, 2014 ©2012 General Electric Company. All rights reserved. Page 1 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/ge-critical-power-ccr0512fp-power-supply.html h t t p: / / pow e r. sa ge r. c om GE CRITICAL POWER Data Sheet GE CCR0512FP SERIES 500 Watt Conduction-Cooled Power Supply CCR0512FP Power Supply Measures: 8.79 x 3.35 x 0.877” 90 - 264Vac Input; 12Vdc, 500W Output Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage. These conditions are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the data sheet’s specifications sections. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Min Max Unit Input Voltage - Continuous 90 264 V ac o Operating Ambient Temperature (see Thermal Considerations section) -20* 55 C o Operating Case Temperature (Cold Plate) -20* 85 C (*See exceptions for spec variations between -10C to -20C) o Storage Temperature -40 90 C Humidity (non-condensing) 30 95 % Altitude 2250 m Isolation Voltage – Input to Output 3000 Vac Input to Chassis 1500 Vdc Output and Signal/Comm pin to Chassis 100 Vdc Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Input Min Typ Max Unit Operating Voltage 90 115/230 264 V ac Source Frequency 47 50/60 63 Hz Turn On Voltage (*Turn On Max may increase to 95 Vac at -20C) 78 85 90* Vac Turn Off Voltage (*Turn Off Max may increase to 90 V at -20C) 73 80 85* V ac ac Turn On/Turn Off Hysteresis 3 4 Vac Current, V = 90V 6.8 A IN ac RMS Fuse Rating, 250Vac 15 A Power Factor, 230V , 100% Load 0.96 % ac Inrush Transient Current, VIN = 264Vac, TA = 25ºC 50 APEAK Efficiency: V = 115V , 20% load 87.0 % IN ac 50% load 90.0 % 100% load 89.0 % VIN = 230Vac, 20% load 87.8 % 50% load 91.8 % 100% load 91.4 % Holdup Time, VIN = 90Vac to 264Vac 80% load, COUT = 2,200 µF, VOUT≥ 10.8Vdc 12 ms Leakage Current to earth ground, V = 264V 3.5 mA IN ac Output 1 – Main Output Min Typ Max Unit Voltage Set-point (50% load) 11.98 12.00 12.02 V dc Voltage Programming Limits 10.8 13.2 Vdc Voltage Tolerance (due to set point, temperature, load, and line regulation) -2 2 %V OUT, set Load Regulation -100 100 mVdc Line Regulation -40 +40 mV dc Ripple and Noise (COUT = 0.1µF ceramic || with 10µF tantalum capacitor) Peak-to-peak (20MHz Bandwidth) 120 mVp-p Dynamic Load Response (50% to 100% load transient, 1A/µs slew rate) Voltage deviation 5 %V OUT, set Settling Time 1.5 ms Current Range 0 42 Adc Current Limit Inception 110 135 %IO,max Current Sharing Accuracy, >20% load -5 5 %I O,max External Capacitance Range 0 10,000 µF Turn On Delay Time from AC Input (*Delay Time Max may increase to 3s at -20C) 2* s Turn On Delay Time from Remote On, VIN within limits 40 ms Rise Time (from 10% to 90% of final value) 50 ms Voltage Overshoot 5 %VOUT, set Turn Off Delay Time from Remote On, V within limits 40 ms IN Over Voltage Protection 13.8 14.8 15.8 Vdc August 12, 2014 ©2012 General Electric Company. All rights reserved. Page 2 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/ge-critical-power-ccr0512fp-power-supply.html h t t p: / / pow e r. sa ge r. c om GE CRITICAL POWER Data Sheet GE CCR0512FP SERIES 500 Watt Conduction-Cooled Power Supply CCR0512FP Power Supply Measures: 8.79 x 3.35 x 0.877” 90 - 264Vac Input; 12Vdc, 500W Output Electrical Specifications (continued) Output 2 – Standby (V ) Output SB Parameter Min Typ Max Unit Voltage Set-point (50% load) Model: CCR0512FPHXXZ01A [VOUT,set] 3.23 3.3 3.37 Vdc Voltage Set-point (50% load) Model: CCR0512FPHX5Z01A [V ] 4.90 5.0 5.10 V OUT,set dc Voltage Tolerance (due to set point, temperature, load, and line regulation) -5 5 %VOUT, set Load Regulation -0.17 +0.17 V dc Line Regulation -0.17 +0.17 Vdc Ripple and Noise (C = 0.1µF ceramic || with 10µF tantalum capacitor) OUT Peak-to-peak (20MHz Bandwidth) 100 mV p-p Dynamic Load Response (50% to 100% load transient, 1A/µs slew rate) Voltage deviation 5 %VOUT, set Settling Time 1.5 ms Current Range 0 2.0 A dc Current Limit Inception 110 150 %IO,max General Specifications Parameter Symbol Typ Unit 9 Calculated Reliability based on Telcordia SR-332 Issue 2: Method 1 Case 3 FIT 602.8 10 /Hours (V =230V , I = 42A, I = 2.0A, T = 30ºC, airflow 200LFM, 90% confidence) MTBF 1,659,038 Hours IN ac o1 o2 A 825 g Weight 29.1 oz. Feature Specification Parameter Min Typ Max Unit Remote On Signal, High turns supply on 2.0 12.0 Vdc Remote Off Signal, Low turns supply off 0.0 0.8 V dc Maximum Remote On/Off Sink Current 4 mA Output Current Monitoring Signal ±250mV 0.1 V/A Environmental Specifications Parameter Specification IPC-9592A Category 1, Class II Product Classification Radiated Emissions FCC and CISPR22 (EN55022) Class A with 3dB margin Conducted Emissions FCC and CISPR22 (EN55022) Class A with 3dB margin Shock & Vibration Operational Test IPC-9592A, section 5.2.8- 5.2.13 Conducted Continuous Wave IPC-9592A, section 5.3.1 Radiated Immunity IPC-9592A, section 5.3.2 Conducted Electrical Fast Transient (EFT) IPC-9592A, section 5.3.3 Conducted Surges IPC-9592A, section 5.3.4 Ring Waves IPC-9592A, section 5.3.5 Electrostatic Discharge –Packaged Power IPC-9592A, section 5.3.6 Power Line Disturbance Immunity IPC-9592A, section 5.3.8 Input Harmonics EN61000-3-2 Safety Specifications Parameter Specification Isolation Voltage Input to Output 3000V (1 minute) ac Isolation Voltage Input to Chassis 1500Vdc Isolation Output/Signal GND to Chassis 100V dc Insulation Resistance Input to Output >10MΩ Safety Certifications UL, CSA, VDE August 12, 2014 ©2012 General Electric Company. All rights reserved. Page 3 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/ge-critical-power-ccr0512fp-power-supply.html h t t p: / / pow e r. sa ge r. c om GE CRITICAL POWER Data Sheet GE CCR0512FP SERIES 500 Watt Conduction-Cooled Power Supply CCR0512FP Power Supply Measures: 8.79 x 3.35 x 0.877” 90 - 264V Input; 12V , 500W Output ac dc Characteristic Curves The following figures provide typical characteristics for the CCR0515FP (12.0V, 42.0A) at 25ºC (unless otherwise noted). O OUTPUT LOAD, % COLD PLATE TEMPERATURE, TC ( C) Figure 1. Converter Efficiency versus % Load. Figure 2. Output Power Derating in Conduction cooling (cold plate) applications; Ta <70ºC adjacent to module. O O AMBIENT TEMPERATURE, TA ( C) AMBIENT TEMPERATURE, TA ( C) Figure 3. Derating Output Current versus Airflow and Figure 4. Derating Output Current versus Airflow and Ambient Temperature, 0.6” horizontal heat sink, front to Ambient Temperature, no heat sink, front to back airflow. back airflow. See Mechanical Figures for airflow direction. See Mechanical Figures for airflow direction. O O AMBIENT TEMPERATURE, TA ( C) AMBIENT TEMPERATURE, TA ( C) Figure 5. Derating Output Current versus Airflow and Figure 6. Derating Output Current versus Airflow and Ambient Temperature, 0.6” vertical heat sink, bottom to top Ambient Temperature, no heat sink, bottom to top airflow. airflow. See Mechanical Figures for airflow direction. See Mechanical Figures for airflow direction. August 12, 2014 ©2012 General Electric Company. All rights reserved. Page 4 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/ge-critical-power-ccr0512fp-power-supply.html h t t p: / / pow e r. sa ge r. c om OUTPUT CURRENT, Io (A) EFFICIENCY, η (%) OUTPUT CURRENT, Io (A) OUTPUT CURRENT, Io (A) OUTPUT CURRENT, Io (A) OUTPUT CURRENT, Io (A) GE CRITICAL POWER Data Sheet GE CCR0512FP SERIES 500 Watt Conduction-Cooled Power Supply CCR0512FP Power Supply Measures: 8.79 x 3.35 x 0.877” 90 - 264V Input; 12V , 500W Output ac dc Characteristic Curves (continued) The following figures provide typical characteristics for the CCR0515FP (12.0V, 42.0A) at 25ºC (unless otherwise noted). TIME, t (200ms/div) TIME, t (200ms/div) Figure 7. Start-up (VIN = 90V, Io = Io,max). Figure 8. Start-up (VIN = 264V, Io = Io,max). TIME, t (5ms/div) TIME, t (5ms/div) Figure 9. Hold-up (VIN = 115V, Io = 80% Io,max). Figure 10. Hold-up (VIN = 230V, Io = 80% Io,max). TIME, t (10µs /div) TIME, t (2ms /div) Figure 11. Output ripple and noise (C =22μF ceramic, VIN = Figure 12. Transient Response to Dynamic Load Change from O 230V, Io = Io,max,). 50% to 100% Io,max at VIN = 230V. August 12, 2014 ©2012 General Electric Company. All rights reserved. Page 5 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/ge-critical-power-ccr0512fp-power-supply.html h t t p: / / pow e r. sa ge r. c om OUTPUT VOLTAGE INPUT VOLTAGE OUTPUT VOLTAGE OUTPUT VOLTAGE INPUT VOLTAGE V (V) (50mV/div) V (V) (100V/div) V (V) (2V/div) V (V) (2V/div) V (V) (350V/div) OUT IN OUT O IN OUTPUT VOLTAGE OUTPUT CURRENT INPUT VOLTAGE OUTPUT VOLTAGE OUTPUT VOLTAGE INPUT VOLTAGE V (V) (200mV/div) I (A) (20Adiv) O O V (V) (200V/div) V (V) (2V/div) V (V) (2V/div) V (V) (350V/div) IN OUT O IN GE CRITICAL POWER Data Sheet GE CCR0512FP SERIES 500 Watt Conduction-Cooled Power Supply CCR0512FP Power Supply Measures: 8.79 x 3.35 x 0.877” 90 - 264V Input; 12V , 500W Output ac dc supply goes into overtemperature shutdown, it will cool Safety Considerations before attempting to restart. The CCR0512 power supply is intended for inclusion in other equipment and the user must ensure that it is in compliance Input Undervoltage Lockout with all the requirements of the end application. At input voltages below the input undervoltage lockout limit, This product is only for inclusion within other equipment and power supply operation is disabled. The power supply will must not be operated as a stand-alone product. begin to operate at an input voltage above the undervoltage lockout turn-on threshold. Thermal Considerations DC OK The power supply can be operated in a variety of thermal The CCR0512 provides a DC OK signal that indicates when environments; however sufficient cooling should be provided the output has come up and is in regulation. This is an open- to ensure reliable operation. collector type signal that goes high when the output is available and within regulation. Considerations include ambient temperature, airflow, power supply dissipation and the need for increased reliability. A Paralleling/Load Share reduction in the operating temperature of the power supply This power supply can be paralleled to provide larger load will result in increased reliability. The thermal derating currents than can be delivered from a single power supply. presented in Figures 2-6 is based on measurements taken in Up to four power supplies may be paralleled. Paralleling is a wind tunnel. accomplished by connecting the Current Share signals of multiple power supplies together. At load current levels above 20%, the output currents of multiple power supplies Feature Descriptions will be within ±5% of the full load value. Standby Power Supply A standby output, V , in the CCR0512 power supply comes SB If remote sense is used when paralleling is employed, the on when AC input in the operating range is applied. remote sense connection points should be common to both power supplies. Remote Sense The power supply has both positive and negative remote The supply is equipped with internal Or-ring mosfets in the + sense connections that can be connected to the positive and VOUT leg and designed for hot swap operation. negative rails of the main output near the load. Care should be taken in routing the sense lines to ensure that noise is not Signal Considerations (Pin Number) picked up or that additional filtering elements that affect the Output Voltage Programming (D4)) stability of the power supply are not used. The power supply will operate without the remote sense connections being Analog input signal - voltage determining the rectifier output voltage. made, however if remote sense near the load is not used it is recommended that the remote sense lines be connected VOUT = 10.8V+ (Vprog X 0.96)V, for Vprog from 0V to 2.5V directly to the main output terminals. VOUT = 13.2V, for Vprog from 2.5V to 3.0V VOUT = 12.0V, for Vprog higher than 3.0V or left open Overcurrent Protection To provide protection in a fault condition (output overload), Output Current Monitoring (B3) the power supply is equipped with internal current-limiting Analog output signal. Voltage proportional to the power circuitry and can endure current limiting continuously. At the supply output current (0.1V/AMP) +/- 250mv. point of current-limit inception, the unit enters hiccup mode. The power supply operates normally once the output current Load Share/Paralleling (C3) is brought back into its specified range. Analog signal. Single wire connection. Unit will load share within ±5% of full load. Overvoltage Protection Overvoltage protection is a feature of the CCR0512 power Remote ON-OFF (E1) supply that protects both the load and the power supply from TTL compatible. Open collector (High) for normal operation. an output overvoltage condition. When an overvoltage Sink current: 4mA. Max collector voltage: 12Vdc occurs, the power supply shuts down and latches off. It is Logic 1 (TTL High) or open enables unit (ON); Logic 0 (TTL Low) necessary to recycle the input to restart the power supply or short shuts unit down (OFF). Cycling this signal resets the when this protection is activated. over-voltage protection memory. Overtemperature Protection AC OK (E3) The CCR0512 also features overtemperature protection in TTL compatible. Open collector (High) for normal operation. order to provide additional protection in a fault condition. The Sink current: 4mA. Max collector voltage: 12Vdc power supply is equipped with a thermal shutdown circuit AC OK indicates that AC is applied within the specified input which detects excessive internal temperatures and shuts the range for the rectifier. unit down. In the event of an over temperature condition, the unit protects itself by providing a low warning signal for 10 DC OK (E2) seconds (typical) and then shutting off. Once the power TTL compatible. Open collector (High) for normal operation. August 12, 2014 ©2012 General Electric Company. All rights reserved. Page 6 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/ge-critical-power-ccr0512fp-power-supply.html h t t p: / / pow e r. sa ge r. c om GE CRITICAL POWER Data Sheet GE CCR0512FP SERIES 500 Watt Conduction-Cooled Power Supply CCR0512FP Power Supply Measures: 8.79 x 3.35 x 0.877” 90 - 264V Input; 12V , 500W Output ac dc Sink current: 4mA. Max collector voltage: 12Vdc Serial Clock (SCL): Clock pulses are host generated initiating communications across the I²C Serial bus, and are pulled up Over Temperature Warning (C5) internally to 3.3V by a 10kΩ resistor. The end user should add TTL compatible. Open collector (High) for normal operation. additional pull up resistance as necessary to ensure that rise Sink current: 4mA. Max collector voltage: 12V . In the event and fall time timing and the maximum sink current is in dc of an over temperature condition, the unit protects itself by compliance to the I²C specifications. providing a low warning signal for 10 seconds (typical) and Serial Data (SDA): This is a bi-directional data line, pulled up then shutting off. Auto restart after the condition is cleared. internally to 3.3V by a 10kΩ resistor. The end user should add additional pull up resistance as necessary to ensure that rise Fault Signal (B2) and fall time timing and the maximum sink current is in TTL compatible. Open collector (High) for normal operation. compliance to the I²C specifications. Sink current: 4mA. Max collector voltage: 12Vdc This alarm is an opto-isolated open collector signal Basic Operation referenced to +V Return or chassis ground. OUT PMBus™ compliance: The power supply is fully compliant to The signal indicates that a failure has been detected in the the Power Management Bus (PMBus™) rev1.2 requirements. unit (OTP, OVP, AC Fail or No Input). Manufacturer specific commands located between addresses 0xD0 to 0xEF provide instructions that either do Signal Return (A3) not exist in the general PMBus specification or make the The signal return is the referenced for all the signals and is communication interface simpler and more efficient. internally connected to the output return (+VOUT leg). Master/Slave: The ‘host controller’ is always the MASTER. Missing Module (B5) Power supplies are always SLAVES. SLAVES cannot initiate Binary signal delivered when the rectifier is present (active communications or toggle the Clock. SLAVES also must low, strap to return signal) respond expeditiously at the command of the MASTER as required by the clock pulses generated by the MASTER. Serial Bus Communications Clock stretching: The ‘slave’ µController inside the power supply may initiate clock stretching if it is busy and it desires All signals are referenced to ‘Signal Return’. to delay the initiation of any further communications. During the clock stretch the ‘slave’ may keep the clock LO until it is Device addressing: The microcontroller (MCU) and the ready to receive further instructions from the host controller. EEPROM have the following addresses: The maximum clock stretch interval is 25ms. Device Address Address Bit Assignments The host controller needs to recognize this clock stretching, (Most to Least Significant) and refrain from issuing the next clock signal, until the clock MCU 0xBx 1 0 1 1 A2 A1 A0 R/W line is released, or it needs to delay the next clock pulse Broadcast 0x00 0 0 0 0 0 0 0 0 beyond the clock stretch interval of the power supply. EEPROM 0xAx 1 0 1 0 A2 A1 A0 R/W Note that clock stretching can only be performed after th completion of transmission of the 9 ACK bit, the exception Address lines (A2, A1, A0): These signal pins allow up to eight being the START command. (8) modules to be addressed on a single I²C bus. The pins are pulled HI internally. For logic LO connect to ‘Output Return’. Global broadcast: This is a powerful command because it instruct all power supplies to respond simultaneously. A read instruction should never be accessed globally. The power supply should issue an ‘invalid command’ state if a ‘read’ is attempted globally. Clock For example, changing the ‘system’ output voltage requires Stretch the global broadcast so that all paralleled power supplies change their output simultaneously. This command can also Figure 13. Example waveforms showing clock turn OFF the ‘main’ output or turn ON the ‘main’ output of all stretching. power supplies simultaneously. Unfortunately, this I²C Bus Lock-Up detection: The device will abort any command does have a side effect. Only a single power transaction and drop off the bus if it detects the bus being supply needs to pull down the ninth acknowledge bit. To be held low for more than 35ms. certain that each power supply responded to the global Communications speed: Both 100kHz and 400kHz clock instruction, a READ instruction should be executed to each rates are supported. The power supplies default to the power supply to verify that the command properly executed. 100kHz clock rate. The minimum clock speed specified by The GLOBAL BROADCAST command should only be executed SMBus is 10 kHz. for write instructions to slave devices. The I²C interface facilitates the monitoring and control of Packet Error Checking (PEC): Although the power supply will various operating parameters within the unit and transmits respond to commands with or without the trailing PEC, it is these on demand over an industry standard I²C Serial bus. highly recommended that PEC be used in all August 12, 2014 ©2012 General Electric Company. All rights reserved. Page 7 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/ge-critical-power-ccr0512fp-power-supply.html h t t p: / / pow e r. sa ge r. c om GE CRITICAL POWER Data Sheet GE CCR0512FP SERIES 500 Watt Conduction-Cooled Power Supply CCR0512FP Power Supply Measures: 8.79 x 3.35 x 0.877” 90 - 264V Input; 12V , 500W Output ac dc communications. The integrity of communications is processors to update their data base so that successive compromised if packet error correction is not employed. reads provide fresh data. There are many functional features, including turning OFF the Invalid commands or data: The power supply notifies the main output, which should require validation to ensure that MASTER if a non-supported command has been sent or the correct command is executed. invalid data has been received. Notification is implemented PEC is a CRC-8 error-checking byte, based on the polynomial by setting the appropriate STATUS and ALARM registers and 8 2 C(x) = x + x + x + 1, in compliance with PMBus™ setting the SMBAlert# flag. requirements. The calculation is based in all message bytes, If a non-supported read is requested the power supply will including the originating write address and command bytes return all 0x00h. preceding read instructions. The PEC is appended to the TM message by the device that supplied the last byte. PMBus Commands SMBAlert#: The µC driven SMBAlert# signal informs the Standard instruction: Up to two bytes of data may follow an ‘master/host’ controller that either a STATE or ALARM change instruction depending on the required data content. Analog has occurred. Normally this signal is HI. The signal will data is always transmitted as LSB followed by MSB. PEC is change to its LO level if the power supply has changed optional and includes the address and data fields. states and the signal will be latched LO until the power 1 8 1 8 1 supply receives a ‘clear’ instruction as outlined below. If the S Slave address Wr A Command Code A alarm state is still present after the ‘clear_faults’ command has been received, then the signal will revert back into its LO 8 1 8 1 8 1 1 state again and will latch until a subsequent ‘clear_faults’ Low data byte A High data byte A PEC A P signal is received from the host controller. Master to Slave Slave to Master SMBUS annotations; S – Start , Wr – Write, Sr – re-Start, Rd – The signal will be triggered for any state change, including Read, the following conditions; A – Acknowledge, NA – not-acknowledged, P – Stop • VIN under or over voltage Standard READ: Up to two bytes of data may follow a READ • Vout under or over voltage request depending on the required data content. Analog • IOUT over current data is always transmitted as LSB followed by MSB. PEC is • Over Temperature warning or fault mandatory and includes the address and data fields. PEC is • Communication error optional and includes the address and data fields. • PEC error • Invalid command 1 7 1 1 8 1 • Detected internal faults S Slave address Wr A Command Code A The power supply will clear the SMBusAlert# signal (release 1 7 1 1 8 1 Sr Slave Address Rd A LSB A the signal to its HI state) upon the following events: • the STATUS_BYTE (0x78) or STATUS_WORD (0x79) are 8 1 8 1 1 read MSB A PEC No-ack P • Receiving a CLEAR_FAULTS command Block communications: When writing or reading more than two bytes of data at a time, BLOCK instructions for WRITE • The main output recycled (turned OFF and then ON) via and READ commands must be used instead of the Standard the REMOTE ON/OFF signal pin Instructions • The main output recycled (turned OFF and then ON) by Block write format: the OPERATION command 1 7 1 1 8 1 S Slave address Wr A Command Code A Read back delay: The power supply issues the SMBAlert # notification as soon as the first state change occurred. 8 1 8 1 8 1 During an event a number of different states can be Byte count = N A Data 1 A Data 2 A transitioned to before the final event occurs. If a read back is implemented rapidly by the host a successive SMBAlert# 8 1 8 1 8 1 1 could be triggered by the transitioning state of the power ………. A Data 48 A PEC A P supply. In order to avoid successive SMBAlert# s and read back and also to avoid reading a transitioning state, it is prudent to wait more than 2 seconds after the receipt of an SMBAlert# before executing a read back. This delay will ensure that only the final state of the power supply is captured. Successive read backs: Successive read backs to the power supply should not be attempted at intervals faster than every one second. This time interval is sufficient for the internal August 12, 2014 ©2012 General Electric Company. All rights reserved. Page 8 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/ge-critical-power-ccr0512fp-power-supply.html h t t p: / / pow e r. sa ge r. c om GE CRITICAL POWER Data Sheet GE CCR0512FP SERIES 500 Watt Conduction-Cooled Power Supply CCR0512FP Power Supply Measures: 8.79 x 3.35 x 0.877” 90 - 264Vac Input; 12Vdc, 500W Output Block read format: command parameters may have their parameters read, regardless of the write_protect settings. The contents of this 1 7 1 1 8 1 register can be stored to non-volatile memory using the S Slave address Wr A Command Code A Store_default_code command. The default setting of this 1 7 1 1 register is disable_all_writes except write_protect 0x80h. Sr Slave Address Rd A FUNCTION DATA BYTE Enable all writes 00 8 1 8 1 8 1 Disable all writes except write_protect 80 Byte count = N A Data 1 A Data 2 A Disable all writes except write_protect and 40 OPERATION 8 1 8 1 8 1 1 Vout_Command (21) : This command is used to change the ………. A Data 48 A PEC NoAck P output voltage of the power supply. Changing the output voltage should be performed simultaneously to all power Linear Data Format The definition is identical to Part II of the supplies operating in parallel using the Global Address PMBus Specification. All standard PMBus values, with the (Broadcast) feature. If only a single power supply is instructed exception of output voltage related functions, are to change its output, it may attempt to source all the required represented by the linear format described below. Output power which can cause either a power limit or shutdown voltage functions are represented by a 16 bit mantissa. condition. Output voltage has a E=-9 constant exponent. Software programming of output voltage permanently The Linear Data Format is a two byte value with an 11-bit, overrides the set point voltage configured by the Vprog two’s complement mantissa and a 5-bit, two’s complement signal pin. The program no longer looks at the ‘Vprog pin’ and exponent or scaling factor, its format is shown below. will not respond to any hardware voltage settings. If power is Data Byte High Data Byte Low removed from the µController it will reset itself into its default Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 configuration looking at the Vprog signal for output voltage Exponent (E) Mantissa (M) control. In many applications, the Vprog pin is used for setting initial conditions, if different that the factory setting. The relationship between the Mantissa, Exponent, and Actual 2 Software programming then takes over once I C Value (V) is given by the following equation: communications are established. E V=M∗2 To properly hot-plug a power supply into a live backplane, Where: V is the value, M is the 11-bit, two’s the system generated voltage should get re-configured into complement mantissa, E is the 5-bit, two’s either the factory adjusted firmware level or the voltage level complement exponent reconfigured by the margin pin. Otherwise, the voltage state Notes: Settings and read backs above support the 12Vdc of the plugged in power supply could be significantly different main output. There are no adjustments or read backs of the than the powered system. standby output. Failure of the standby output is reported by Vout_OV_warn_limit (42): OV_warning is extremely useful the STATUS_MFR_SPECIFIC register. The code does not check because it gives the system controller a heads up that the the validity of, or whether the data being changed is within the output voltage is drifting out of regulation and the power expected boundary. The user is responsible to make sure that supply is close to shutting down. Preemptive action may be data placed in the registers is within the monitored range. taken before the power supply would shut down and Command Descriptions potentially disable the system. OC and OT_fault_ response (47, 50): The default response Operation (01) : By default the Power supply is turned ON at for both OC and OT is auto_restart (hiccup). Each register, power up as long as Power ON/OFF signal pin is active HI. The individually, can be reconfigured into a latched state. Operation command is used to turn the Power Supply ON or Latched and hiccup are the only supported states. OFF via the PMBus. The data byte below follows the OPERATION command. Restart after a latch off: Either of four restart possibilities are FUNCTION DATA BYTE available. The hardware pin Remote ON/OFF may be turned Unit ON 80 OFF and then ON. The unit may be commanded to restart via Unit OFF 00 i2c through the Operation command by first turning OFF then turning ON . The third way to restart is to remove and reinsert the unit. The fourth way is to turn OFF and then turn ON ac To RESET the power supply cycle the power supply OFF, wait power to the unit. Each of these commands must keep the at least 2 seconds, and then turn back ON. All alarms and power supply in the OFF state for at least 2 seconds, with the shutdowns are cleared during a restart. exception of changing to restart. Clear_faults (03): This command clears all STATUS and A power system that is comprised of a number of power FAULT registers and resets the SMBAlert# line. supplies could have difficulty restarting after a shutdown If a fault still persists after the issuance of the clear_faults event because of the non-synchronized behavior of the command the specific registers indicating the fault are reset individual power supplies. Implementing the latch-off and the SMBAlert# line is activated again. mechanism permits a synchronized restart that guarantees WRITE_PROTECT register (10): Used to control writing to the the simultaneous restart of the entire system. PMBus device. The intent of this command is to provide A synchronous restart can be implemented by; protection against accidental changes. All supported August 12, 2014 ©2012 General Electric Company. All rights reserved. Page 9 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/ge-critical-power-ccr0512fp-power-supply.html h t t p: / / pow e r. sa ge r. c om GE CRITICAL POWER Data Sheet GE CCR0512FP SERIES 500 Watt Conduction-Cooled Power Supply CCR0512FP Power Supply Measures: 8.79 x 3.35 x 0.877” 90 - 264V Input; 12V , 500W Output ac dc 1. Issuing a GLOBAL OFF and then ON command to all power Register Code Bit Function supplies, 7 OT Fault 2. Toggling Off and then ON the Remote ON/OFF signal 6 OT Warning 3. Removing and reapplying input commercial power to the 5 UT Fault entire system. Status_temp 4 UT Warning 7D erature 3 N/A The power supplies should be turned OFF for at least 20 – 30 2 N/A seconds in order to discharge all internal bias supplies and 1 N/A Vin_UV_warn_limit (58): This is another warning flag 0 N /A indicating that the input voltage is decreasing dangerously 7 Invalid Command close to the low input voltage shutdown level. 6 Invalid Data 5 ERROR PEC Status_word (79): returns two bytes of information. The 4 N/A upper byte bit functionality is tabulated in the Status_word Status_cml 7E 3 N/A section. The lower byte bit functionality is identical to 2 N/A Status_byte. 1 Other Fault 0 N/A 7 0 = V Fault, 1 = No V Fault SB SB 6 0 = OV Fault, 1 = No OV Fault 5 0 = Interrupt, 1 = No Interrupt 4 0 = Any Fault, 1 = No Fault Status_mfr_ 80 specific 3 0 = OT Fault; 1 = Temperature OK Status Register Bit Allocation: 2 0 = DC Fault, 1 = DC OK Register Code Bit Function 1 0 = Input AC Fault, 1 = Input AC OK 7 N/A 0 0 = AC high line, 1 = AC low line 6 N/A 5 Output OV Fault detected Mfr_ID (99): Manufacturer in ASCII – 5 characters maximum, 4 Output OC Fault detected Status_Byte 78 General Electric – Critical Power represented as, ‘GECP_’ 3 Input UV Fault detected 2 Temperature Fault/warning detected Mfr_Model (9A): Total 15 bytes: ‘CCR0512FPXXZ01A’ 1 CML (communication fault) detected Mfr_Location (9C): Total 4 bytes: ‘CHN_‘ 0 N/A Mfr_Date (9D): Total 6 bytes: yymmdd 7 OV Fault detected Mfr_Serial (9E): Total 15 bytes 6 OC Fault detected 5 Input Fault detected Read_mfr_rev (D0): Total 1 bytes Status_word 4 N/A (includes 79 Each byte is partitioned into high and low nibbles. 3 N/A Status_byte) Example: FF (11111111) is read as 16.16 2 N/A 1A (00011010) is read as 1.10 1 N/A 0 N/A 7 Vout OV Fault EEPROM 6 Vout OV Warning The microcontroller has 96 bytes of EEPROM memory 5 Vout UV Warning available for the system host. 4 Vout UV Fault Status_Vout 7A 3 N/A 2 N/A 1 N/A 0 N/A 7 IOUT OC Fault 6 N/A 5 IOUT OC Warning 4 N/A Status_Iout 7B 3 N/A 2 N/A 1 N/A 0 N/A 7 Vin OV Fault 6 Vin OV Warning 5 Vin UV Warning 4 Vin UV Fault Status_input 7C 3 N/A 2 N/A 1 N/A 0 N/A August 12, 2014 ©2012 General Electric Company. All rights reserved. Page 10 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/ge-critical-power-ccr0512fp-power-supply.html h t t p: / / pow e r. sa ge r. c om GE CRITICAL POWER Data Sheet GE CCR0512FP SERIES 500 Watt Conduction-Cooled Power Supply CCR0512FP Power Supply Measures: 8.79 x 3.35 x 0.877” 90 - 264V Input; 12V , 500W Output ac dc TM PMBus Command set: Hex Data Read/ Command Function Factory Default/Notes Code Byte Write 01 OPERATION 1 R/W Output ON/OFF 0x80/ Only 0x00 and 0x80 allowed 02 ON_OFF_CONFIG 1 R On/Off Control Configuration 0x09/ Only 0x09 allowed 03 CLEAR_FAULTS 0 Clear Status 10 WRITE_PROTECT 1 R/W Write control 0x80 11 STORE_DEFAULT_ALL 0 W Store permanently 12 RESTORE_DEFAULT_ALL 0 W Reset defaults 19 CAPABILITY 1 R PEC support (data ≥ 2 byte); 400kHz; SMBAlert 0x30 20 VOUT_MODE 1 R Vout constants, Exp=-9 0x17 21 VOUT_COMMAND 2 R/W Set Output Vout 12.0V 40 VOUT_OV_FAULT_LIMIT 2 R/W Set Output OV fault limit 14.0V 41 VOUT_OV_FAULT_RESPONSE 1 R/W Set Response to Output OV fault 0xC0 42 VOUT_OV_WARN_LIMIT 2 R/W Set Output OV warn limit 13.5V 43 VOUT_UV_WARN_LIMIT 2 R/W Set Output UV warn limit 10.5V 44 VOUT_UV_FAULT_LIMIT 2 R/W Set Output UV fault limit 10.0V 45 VOUT_UV_FAULT_RESPONSE 1 R/W Set Response to Output UV fault 0xC0 46 IOUT_OC_FAULT_LIMIT 2 R/W Set Output OC fault limit 48A 47 VOUT_OC_FAULT_RESPONSE 1 R/W Set Response to Output OC fault 0xC0 4A IOUT_OC_WARN_LIMIT 2 R/W Set Output OC warn limit 45A 4F OT_FAULT_LIMIT 2 R/W Set OT fault limit 112C 50 OT_FAULT_RESPONSE 1 R/W Set Response to OT fault 0xC0 51 OT_WARN_LIMIT 2 R/W Set OT warn limit 100C 55 VIN_OV_FAULT_LIMIT 2 R/W Set Input OV fault limit 270V 57 VIN_OV_WARN_LIMIT 2 R/W Set Input OV warn limit 266V 58 VIN_UV_WARN_LIMIT 2 R/W Set Input UV warn limit 90V 59 VIN_UV_FAULT_LIMIT 2 R/W Set Input UV shutdown 83V 78 STATUS_BYTE 1 R 79 STATUS_WORD 2 R 7A STATUS_VOUT 1 R 7B STATUS_IOUT 1 R 7C STATUS_INPUT 1 R 7D STATUS_TEMPERATURE 1 R 7E STATUS_CML 1 R 7F STATUS_OTHER 1 R 80 STATUS_MFR_SPECIFIC 1 R 88 READ_VIN 2 R Read input voltage 89 READ IIN 2 R Read input current 8B READ_VOUT 2 R Read output voltage 8C READ_IOUT 2 R Read output current 8D READ_TEMPERATURE 2 R Read temperature 96 READ_POUT 2 R Read output power 97 READ_PIN 2 R Read input power 98 PMBUS REVISION 1 R 0x11 99 MFR_ID 5 R ASCII 9A MFR_MODEL 15 R ASCII 9C MFR_LOCATION 4 R FRU_ID ASCII 9D MFR_DATE 6 R ASCII 9E MFR_SERIAL 15 R ASCII B0 USER_DATA_00 48 R/W User memory space B1 USER_DATA_01 48 R/W User memory space D0 READ_FRW_REVISION 1 R 1.10 Specifications are subject to change without notice. It is r August 12, 2014 esponsibility of each customer to thor ©20oughly test each pr 12 General Elec oduct and par tric Comt number under their unique parameters and envir pany. All rights reserved. onments to ensure a product will work pr Page operly and r 11 eliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/ge-critical-power-ccr0512fp-power-supply.html h t t p: / / pow e r. sa ge r. c om Data Sheet GE CRITICAL POWER GE CCR0512FP SERIES 500 Watt Conduction-Cooled Power Supply CCR0512FP Power Supply Measures: 8.79 x 3.35 x 0.877” 90 - 264V Input; 12V , 500W Output ac dc Visual Indicators (LEDs) AC OK (Green) DC OK (Green) FAULT (Red) Connector Information Connector On Power Supply Mating Connector Molex part # 46437-1154 Molex part # 46436-1154 (Right Angle Mounting) Pin No. Function Pin No. Function Pin No. Function 2 A1 +VSB C1 SDA (I C bus) E1 Remote ON/OFF 2 A2 -VSB Return C2 SCL (I C bus) E2 DC OK A3 Signal Return C3 Ishare E3 AC OK A4 Write Protect (WP) C4 N/C E4 Interrupt (/SMBALERT) A5 Remote Sense (+) C5 Over Temperature Warning E5 RTN 2 B1 Remote Sense (-) D1 I C Address (A0) P1 +VOUT 2 B2 Fault D2 I C Address (A1) P2 V RTN OUT 2 B3 I Monitor (IMON) D3 I C Address (A2) P3 SAFETY GND B4 Module Enable D4 V P4 AC NETURAL prog B5 PSU Present D5 OVP Test Point P5 AC LINE Yellow denotes short pins (last to make), Green denotes long pins (first to make). August 12, 2014 ©2012 General Electric Company. All rights reserved. Page 12 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/ge-critical-power-ccr0512fp-power-supply.html h t t p: / / pow e r. sa ge r. c om GE CRITICAL POWER Data Sheet GE CCR0512FP SERIES 500 Watt Conduction-Cooled Power Supply CCR0512FP Power Supply Measures: 8.79 x 3.35 x 0.877” 90 - 264V Input; 12V , 500W Output ac dc Mechanical Outline Dimensions are in inches. Tolerances: x.xxx in. ± 0.02 in. [unless otherwise indicated] Specifications are subject to change without notice. It is r August 12, 2014 esponsibility of each customer to thor ©20oughly test each pr 12 General Elec oduct and par tric Comt number under their unique parameters and envir pany. All rights reserved. onments to ensure a product will work pr Page operly and r 13 eliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/ge-critical-power-ccr0512fp-power-supply.html h t t p: / / pow e r. sa ge r. c om GE CRITICAL POWER Data Sheet GE CCR0512FP SERIES 500 Watt Conduction-Cooled Power Supply CCR0512FP Power Supply Measures: 8.79 x 3.35 x 0.877” 90 - 264V Input; 12V , 500W Output ac dc Ordering Information Please contact your GE Power Electronics’ Sales Representative for pricing, availability and optional features. Device Codes Product Code Input Voltage Output Power Output Ratings Comcode CCR0512FPXXXZ01A 90-264Vac 500W 12Vdc/42A, 3.3Vdc/2.0A CCR0512FPXXXZ01A Accessories Item Description Product Code/Comcode Source Horizontal 0.6 in. Heatsink CCR0512FPKITZ01A GE plus screws (5) Vertical 0.6 in. Heatsink CCR0512FPKITZ02A GE plus screws (5) Interface Card 150036347 GE Contact Us For more information, call us at USA/Canada: +1 888 546 3243, or +1 972 244 9288 Asia-Pacific: +86.021.54279977*808 Europe, Middle-East and Africa: +49.89.878067-280 India: +91.80.28411633 www.gecriticalpower.com GE Critical Power reserves the right to make changes to the product(s) or information contained herein without notice, and no liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. August 12, 2014 ©2012 General Electric Company. All International rights reserved. Version 1.5 Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/ge-critical-power-ccr0512fp-power-supply.html h t t p: / / pow e r. sa ge r. c om

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the CCR0512FPXXXZ01A?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

400W, 24V, UNIVERSAL AC INPUT FRONT END, TOP SIDE FAN

product

400 W, Single Output, 24 VDC@16.7 A Open Frame AC-DC Power Supply

product

850 W, Single Output, 12 VDC@71 A Enclosed AC-DC Power Supply

product

850 W, Single Output, 12 VDC@71 A Enclosed AC-DC Power Supply

product

850W, 12V, UNIVERSAL AC INPUT FRONT END, CLASS A EMI

product

850 W, Single Output, 12 VDC@71 A Enclosed AC-DC Power Supply