Electronics Finder chervon right Manufacturers chervon right I chervon right IDEC CORPORATION chervon right AS6M-21Y2P
About product Specifications Datasheet FAQ

IDEC CORPORATION AS6M-21Y2P

Image of IDEC CORPORATION AS6M-21Y2P

Description

Switch Selector N.O./N.C. SPDT 90?? Knob 1A 250VAC 250VDC Quick Connect/Solder 250000Cycles Panel Mount
AS6M-21Y2P

Part Number

AS6M-21Y2P

Price

Request Quote

Manufacturer

IDEC CORPORATION

Lead Time

Request Quote

Category

Switches »  Switch Selector

Specifications

Manufacturer

IDEC Corporation

Manufacturers Part #

AS6M-21Y2P

Lead Time

9 Week Lead Time

Industry Aliases

AS6M-21Y2P

Sub-Category

Selector Switches

Factory Pack Quantity

1

Datasheet

pdf file

A_Switches_ScreenView.pdf

5611 KiB

Extracted Text

Switches & Pilot Devices www.idec.com/switches Section A Overview • Selection Guide . . . . . . . . . . . . A-2 • General Information . . . . . . . A-12 Section A1: Safe Break E-Stops • World’s Safest E-Stops XA Ø 16mm & XW Ø 22mm . . . . . . . . . . . . . . . A1-14 A2: ø16mm Switches & Pilot Devices • A6 Series Ø 16mm. . . . . . . . . . . A2-17 • L6 Series Ø 16mm . . . . . . . . . . . A2-30 A3: ø22mm Switches & Pilot Devices • HW Series Ø 22mm. . . . . . . . . . A3-52 • LW Series Ø 22mm . . . . . . . . . A3-108 • TW Series Ø 22mm . . . . . . . . . A3-126 A A4: ø30mm Switches & Pilot Devices • TWTD Series Ø 30mm . . . . . . A4-166 • Cam - CS Series . . . . . . . . . . . A4-195 • Mono Lever - ARN Series . . . A4-202 A5: Miniature Switches & Pilot Devices • A8 Series Ø 8mm. . . . . . . . . . . A5-205 • AP Series Miniature Pilot Lights Ø 8-16mm . . . . . . . . . . . . . . . A5-210 for more information on this product family visit www.idec.com/switches Additional Web Resources • New and updated product information • Downloadable software demos & upgrades • Part conŢguration tool & cross reference • Online stock check & ordering • IDEC Ţeld sales & distributor search • Online literature request • Downloadable manuals & CAD drawings • Manufacturer’s suggested retail price list • Product training schedule & locations • Advertising & trade show schedules • Press releases & FAQs New New HW Dual Pushbutton Switches now available. See page A3-84. Selection Guide Switches & Pilot Devices Selection Guide A1: Safe Break E-Stops: 16mm XA & 22mm XW Series World’s Safest Emergency Switches Series Model XA XW A Appearance See Page A1-14 A1-14 Non-illuminated E-Stops: Illuminated & Non-Illuminated E-Stops: Operator Type Pushlock/Turn Reset, Push-Pull Pushlock/Turn Reset, Push-Pull Reset Action Pushlock Pull or Turn Reset (both actions available in each switch) Contact Configuration 1NO - 1NC, 2NC, 1NO-3NC, 4NC 1NO - 1NC, 2NC, 1NO-3NC, 4NC Electrical Life 100,000 Minimum 250,000 or more (24V AC/DC 100mA) Mechanical Life 250,000 Minimum Termination PCB & Solder Terminals Screw Terminals Degree of Protection IP65 (IEC60529) Approvals XA series UL recognized. A-2 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC NEW NEW Switches & Pilot Devices Switches & Pilot Devices Switches & Pilot Devices Selection Guide A2: Ø16mm Switches & Pilot Devices - A6 Series Series Model AL6 AB6 AL6 AB6 AB6-V AS6 AS6-K A Appearance See Page A2-20 A2-18 A2-20 A2-18 A2-18 A2-24 A2-24 Keylock Illuminated Non-Illuminated Oversize Lens Oversize Button Selector Switches: Pushbuttons: Pushbuttons: Illuminated Non-illuminated Emergency Stop: Switches: • 2 or 3-Position Operator Type • Momentary • Momentary Pushbuttons: Pushbuttons: • Pushlock / • 2 or 3-Position • Maintained or • Maintained • Maintained • Momentary • Momentary Turn Reset • Maintained or Spring Return • Pilot Lights • Maintained • Maintained Spring Return • Key removable options Round: 18mm Round: 23.5mm Round: 18mm Bezel/Lens Square: 18mm Square: 23.5mm Round: 23.5mm Square: 18mm Shape & Size Rectangular: 18 x 24mm Rectangular: 17.5 x 23.5mm Rectangular: 18 x 24mm Light SourceLED —LED — — — — Amber, Green, Black, Blue, Amber, Green, Black, Blue, Lens/Button Red, White, Green, Red, Red, White, Green, Red, Red Black — Colors Yellow, Blue White, Yellow Yellow, Blue White, Yellow Contact SPDT or DPDT (Gold-Clad Silver Contact) Configuration Contact 120V AC/1A, 24V DC/1A (Resistive) (Minimum applicable load reference value: 5V AC/DC, 1mA) Ratings Electrical Momentary: 100,000 operations minimum 100,000 100,000 operations minimum Maintained: 50,000 operations minimum operations (at 1,200 operations/hour) Life Mechanical Momentary: 1,000,000 operations minimum 100,000 250,000 operations minimum Maintained: 100,000 operations minimum operations Life Degree of Enclosed/Dustproof: IP40 Waterproof/Oiltight/Corrosion Resistant: IP65 Protection Termination .110" Solder/Quick Connect CSA CertiŢed CertiŢcate No. UL Recognized Approvals 2030010305027380 File No. LR48366 File No. E55996 1. LED lamps contain a built-in current-limiting resistor and reverse polarity protection diode. 2. Available as assembled or sub-assembled components. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A-3 Selection Guide Switches & Pilot Devices A2: Ø16mm Switches & Pilot Devices - L6 Series Series HA1B-V/ LA3Z/LA1T/ LAΔB/HAΔB LAΔP/HAΔP LAΔL/HAΔL LAΔS/HAΔS LAΔK/HAΔK LAΔF/HAΔF Model HA1E-V HA1R A Appearance Direct Opening Action See Page A2-30 A2-34 A2-36 A2-33 A2-38 A2-40 A2-42 A2-33, A2-44 Piezo Buzzer Key Switch Illuminated Illuminated: Lever Switch Non-illuminated: E-Stop Selector Switch • 2pos/3pos Selector Operator Pilot Light • Momentary • 2 pos/ 3pos • Momentary • Pushlock/ • 2 pos/ 3pos • Spring/Maint • 2 pos/ 3pos Types • LED/Incan. • Maintained • Spring/Maint • Maintained Turn Reset • Spring/Maint • Key Remove • Spring/Maint • LED/Incan. PB/ Selector Option • LED/Incan. • 2 pos/ 3pos Rnd: 18mm Rnd: 18mm Rnd: 18mm Rnd: 18mm Sq: 18mm Sq: 18mm Sq: 18mm BZR: 18 x 24mm Bezel Shape Sq: 18mm Rect: 18 x 24mm Rect: 18 x 24mm Rect: 18 x 24mm Rnd: 25mm Lvr: 18mm Rect: 18 x 24mm and Size Ovrsze Rnd: 24mm Ovrsze Rnd: 24mm Ovrsze Rnd: 24mm PB/Selector: 25mm Ovrsze Rnd: 24mm Ovrsze Sq: 24mm Ovrsze Sq: 24mm Ovrsze Sq: 24mm LED: 5VDC/6V, 12V, LED: 5VDC/6V, LED: 5VDC/6V, 24V AC/DC 12V, 24V AC/DC 12V, 24V AC/DC Light Source – –– – – Incan: 5V/6V, 12V, Incan: 5V/6V, 12V, Incan: 5V/6V, 24V AC/DC 24V AC/DC 12V, 24V AC/DC Amber, Green, Amber, Green, Amber, Green, Lens/Button Amber, Green, Red, Red, Blue, White, Red, Blue, White, Red Black/White Black/Silver Red, Blue, – Blue, White, Yellow Colors Yellow Yellow White, Yellow DPST-NC Contact SPDT, DPDT – SPDT, DPDT (positive DPDT DPDT Configuration action) 100,000 100,000 Electrical Incan: 2000 hrs operations min operations min – LED: 50,000 hrs Life (at full rated load) (at full rated load) Momentary: Momentary: Momentary: Mechanical 2,000,000 2,000,000 250,000 2,000,000 – – Maintained: Maintained: operations Maintained: Life 250,000 250,000 250,000 Degree of IP65 Protection Termination 0.110”solder/quick connect, PCB pins Reg.No. R9551089 UL Recognized CSA CertiŢed HA1B-V, Approvals Reg. No. J9551458 HA1E only File No. E55996 File No. LR21451 Reg. No. J9650511 A-4 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Switches & Pilot Devices Selection Guide A3: Ø22mm Oiltight Switches and Pilot Devices - HW Series Series Model HWΔB– HWΔP– HWΔL– HW1B, HW1E HW1S, HW1K, HW1F– HW7D, HW1M, HW1R - Push–Pull Flush Flush Pushlock Turn Reset A Knob Operator Extended Dual Pushbutton Pushlock Turn Reset Dome Lens Flush (metal bezel) Knob Operator Extended (metal bezel) (metal bezel) Pushlock Turn Reset Dome Lens (metal bezel) Extended (metal bezel) Mono-Lever 40mm Mushroom Key Operator Flush Lens Pushlock Key Reset Appearance Extended/Shroud Square Flush Key Operator (metal bezel) Pushbutton Selector Jumbo Pushlock Square Flush Turn Reset 40mm Mushroom Square Extended Illuminated Unibody E-Stop Square Extended Jumbo Mushroom Illuminated Unibody E-Stop See Page A3-54 A3-61 A3-64 A3-52 A3-68, A3-71, A3-74 A3-84, A3-89, A3-91 E-Stops: Selector Switches HW7D Illuminated • Modular or Unibody • Non-Illuminated Dual Pushbutton Non-illuminated Pushbuttons: • Non-Illuminated • Illuminated HW1M Pushbuttons: Pilot Lights Operator Types • Momentary • Illuminated • LED/Incandescent Monolever • Momentary • LED/Incandescent • Maintained (unibody only) • 2, 3, 4, 5- position • 2 or 4 position • Maintained • LED/Incandescent • key reset (key & illum. 2 or 3- HW1R (all units meet EN418) position only) Selector Pushbutton Modular: Modular: Modular: Modular: Contact (NO, NC, NO, NC, NO-EM, 2NC, 1NO/1NC NO, NC, NO-EM, NO, NC, NO-EM, — Configuration NO-EM, NC-LB NC-LB (Unibody) NC-LB NC-LB (maximum 6 contacts) (maximum 6 contacts) (maximum 6 contacts) (maximum 6 contacts) Electrical MTBF < 1 fault in 10 million operation cycles (3V DC, 5mA) Reliability Momentary Pushbuttons: 5,000,000 operations minimum (900 operations per hour) Mechanical Life All other switches: 500,000 HW1R: IP65, IP20 IP65 (from front of the panel), Degree of NEMA 1, 2, 3, 3R, 3S, 4, IP20 (type HW-F contact blocks) (conforming to IEC60529) Protection 4x, 5, 12, 13 NEMA Type 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (conforming to NEMA ICS-110) HW1M: IP40, IP20 Termination M3.5 screw terminals (Ţngersafe/spring-up/exposed screw) with captive sems plate Direct Opening Action Approvals (NC contacts only) Certificate No. CSA Certified UL Listed Reg No. R9551089 (E-stops) 2005010305145656 File No. LR92374 File No. E68961 Reg No. J9551458 (all other switches) Reg No. J9650511 (Pilot Lights) www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A-5 NEW Selection Guide Switches & Pilot Devices A3: Ø22mm Oiltight Switches and Pilot Devices - LW Series Series Model LWΔB– LWΔL– LW1S– LW1F LW1K LWΔP– Flush Round A Extended Round Square Square Flush Square Appearance Round Unibody Square Extended Mushroom Square Unibody Mushroom See Page A3-110 A3-112 A3-116 A3-116 A3-116 A3-114 Non-Illuminated Illuminated Pilot Light Key Selector: Pushbuttons Pushbuttons: Illuminated Selector: • LED/Incan. Selector Switch: • 2 or 3- position Operator Type • Momentary • Momentary • 2 or 3- position • Standard/ • 2 or 3- position • Key removable • Maintained • Maintained • LED/Incan. Unibody options • LED/Incan. SPDT, DPDT, 3PDT — Contact Configuration Gold-clad crossbar contacts 30VDC/1A, 125VAC/1A resistive Contact Ratings — Silver Contacts 30VDC/2A, 125VAC/3A, 250VAC/2A resistive 30VDC/1A, 125VAC/2A,250VAC/1.5A inductive Momentary: 1,000,000 operations minimum, Mechanical Life Maintained: 500,000operations, Selectors: 250,000 operations minimum Electrical Life Momentary: 100,000 (1800 operations/hour) — Maintained: 100,000 (900 operations/hour) (at rated load) Degree of Protection Oiltight/watertight: IP65 IP65 (conforming to IEC529) •.110" solder/quick connect Termination • PCB (gold contacts only) • M3 screw (2 pole only) CSA CertiŢed UL Recognized Reg. No. Approvals J9551801 File No. LR21451 File No.E55996 1. Lamps not included in assembled units. 2. Available as assembled or sub-assembled components. A-6 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Switches & Pilot Devices Selection Guide A3: Ø22mm Oiltight Switches and Pilot Devices - TW Series Series Model AΔW... AΔLW... ASW... ASLW... APW... Flush Extended A Dome Lens Extended Extended/Shroud Knob Operator Flush Lens Mushroom Mushroom Knob Operator Lever Operator (w/transformer) Appearance Square Flush Square Flush Square Extended Key Operator Square Flush Square Extended Push-Pull (w/transformer) Pushlock Turn Reset Pushlock Turn Reset See Page A3-128 A3-138 A3-142 A3-146 A3-135 Illuminated Selector Switches: Non-illuminated Pushbuttons: • 2, 3, 4, 5-position Illuminated Selectors: Pilot Lights: Pushbuttons: • Momentary • Maintained • Full Voltage/ • Full Voltage/ Operator Types • Momentary • Maintained • Spring Return Transformer Transformer • Maintained • E-Stop • Colored knobs/ • LED/Incandescent • LED/Incandescent • E-Stop • LED/Incandescent inserts Modular: Contact Configuration NO,NC, NO-EM, NC-LB See Contact Arrangement Charts page A3-150. — (maximum 6 contacts) Contact Ratings 10A thermal current/600V maximum Electrical Life 500,000 operations/min Momentary Pushbuttons: 5,000,000 operations minimum; Mechanical Life Others: 500,000 operations minimum Selector Switches: 500,000 operations minimum NEMA Type 1, 2, 3, 3R, 4, 4X, 5, 12, 13; Degree of Protection Waterproof/Oiltight/Corrosion Resistant: IP65 Termination M3.5 Screw Terminals with captive sems plate Direct Opening Action Approvals UL Listed CSA CertiŢed (NC contacts only) File No. 9561116E01 Certificate No. File No. E70646 File No. LR48366 2030010305027380 1. Illuminated units include lamp. 2. Available as assembled or sub-assembled components. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A-7 Selection Guide Switches & Pilot Devices A4: Ø30mm Oiltight Switches and Pilot Devices - TWTD Series Series Model AΔD... AΔLD... ASD... AΔLD... APD... Flush Extended A Extended/ Neoprene Boot Knob Operator Extended/Shroud Knob Operator (full voltage) Dome Lens Mushroom Lever Operator Mushroom Dome Lens Knob Operator Appearance (w/transformer) Jumbo Mushroom (with transformer) Key Operator Pushlock Turn Reset Pushlock Turn Reset Push-Pull Push-Pull See Page A4-168 A4-174 A4-179 A4-182 A4-174 Illuminated Selector Switches: Non-illuminated Illuminated Selectors Pushbuttons: • 2, 3-position Pilot Lights Pushbuttons: • LED/Incandescent • Momentary • Maintained • Full Voltage/ Operator Type • Momentary • 2, 3-position • Maintained • Spring return Transformer • Maintained • Maintained • Special (E-Stop) • Key removable • LED/Incandescent • E-Stop • Spring return • LED/Incandescent options Modular: NO, NC, NO-EM, NC-LB See Contact Arrangement Charts on Contact Configuration — (maximum 6 contacts) page A4-185. 10A thermal current Contact Ratings — 600V maximum 500,000 operations minimum (pushbuttons and selector switches) Electrical Life — Operating Frequency: 30 operations/minute, Duty Rate 40% Momentary Pushbuttons: 5,000,000 operations minimum; Mechanical Life Others: 500,000 operations minimum NEMA Type 1, 2, 3, 3R, 4, 4X, 5, 12, 13 Degree of Protection Waterproof/Oiltight/Corrosion Resistant: IP65 Termination M3.5 Screw Terminals with captive sems plate Approvals File No. DK95-00717 UL Listed CSA CertiŢed Certificate No. File No. E70646 File No. LR48366 2005010305145656 1. Illuminated units include lamp. 2. Available as assembled or sub-assembled components. A-8 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Switches & Pilot Devices Selection Guide A4: Ø30mm Switches - Cam and Mono-Lever Series Model ACSNO ACSNK UCSQO UCSQM ARN Mounting Hole Diameter Ş 1–13/64" (30mm) 5 hole panel cutout Ş 1 13/64" (30mm) Standard Knob (ARNO) A Short Knob (ARNSO) Appearance Interlock knob (ARNLO) See Page A4-195 A4-202 Cam Switch Cam Switch Cam Switch w/knob & Cam Switch 3-pos, Operator Types Mono-lever Switch w/knob selector w/key selector mechanical indicator. spring-return 30° Up to 12 positions • Center + 2, 3, or Cam Angles 45° Up to 8 positions Spring-return 45° 4 position 60° Up to 6 positions 3 position only • Maintained and/or Positions 90° Up to 4 positions • Spring return 10A thermal current Contact Ratings 600V insulation voltage Electrical Life: 500,000 operations minimum (at full rated load) Mechanical Life 500,00 operations minimum Degree of Protection IP65, NEMA 4, 13 IP40 IP65, NEMA 4, 13 IP40 Termination M3.5 Screw Terminals with captive sems plate CSA CertiŢed UL Listed Approvals File No. LR48366 File No. E68961 1. Cam switches available only as assembled units. 2. Mono-lever switches available as assembled or sub-assembled components. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A-9 Selection Guide Switches & Pilot Devices A5: Miniature Switches and Pilot Devices - Ø8mm A8 Series Series Model AL8 AB8 A Appearance See Page A5-205 A5-205 Illuminated Pushbuttons: Non-Illuminated Pushbuttons: • Momentary • Momentary Operator Type • Maintained • Maintained • Pilot Lights Round: Ş 0.351 (9mm) Lens Shape and Size Square: ❏ 0.351 (9mm) Rectangular: 0.351 x 0.468 (9 x 12mm) Light SourceLED — Lens/Button Colors Amber, Green, Red, White, Yellow Black, Blue, Green, Red, White, Yellow Contact Configuration SPDT (Gold-Clad Silver Contact) 120V AC/1A, 24V DC/1A, (Resistive), Contact Ratings Minimum applicable load reference value: 5V AC/DC, 1mA Electrical Life Momentary: 100,000 operations minimum Maintained: 50,000 operations minimum (at full rated load) Momentary: 200,000 operations minimum Mechanical Life Maintained: 100,000 operations minimum Degree of Protection Enclosed/Dustproof: IP40 Termination Solder Tab Terminal CSA CertiŢed UL Recognized Approvals File No. LR21451 File No. E55996 1. LED lamps require an external current limiting resistor. 2. Available as assembled units only (replacement LED lamps available). A-10 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Switches & Pilot Devices Selection Guide A5: Miniature Pilot Lights - Ø8 to 16mm AP Series Series Model AP8M AP1M AP2M AP6M Mounting Hole Diameter 8mm 10mm 12mm 16mm Dome Dome Dome Dome A Appearance Flat Flat Flat Flat See Page A5-211 Operator Type Pilot Lights Flat & Dome Flat & Dome Flat & Dome Flat & Dome Lens Shape and Size Ş 9.8mm Ş 12mm Ş 14mm Ş 18mm Light Source LED (with built-in current limiting resistor) Lens Colors Amber, Green, Red, White, Yellow 6, 12, 24V DC (Full Voltage); 6, 12, 24V DC (Full Voltage) 120, 240V AC (with transformer); Voltages 110V DC (with DC-DC converter). 6V DC/18mA 6V DC/18mA 6V DC/33mA 6V DC/33mA 12V DC/11mA 12V DC/11mA 12V DC/22mA 12V DC/11mA Rated Current 24V DC/12mA 24V DC/12mA 24V DC/11mA 24V DC/11mA Degree of Protection Enclosed/ Dustproof: IP40 Waterproof/Oiltight/Corrosion Resistant: IP65 Termination Solder Tab .110" Solder/Quick Connect CSA CertiŢed UL Recognized Approvals File No. LR48366 File No. E68961 1. Only AP6 accepts.110" quick-connect. 2. AP2 and AP6 compatible with snap-on transformers. 3. All units are one-piece pilot lights with non-replaceable LED lamp. 4. All units include built-in current limiting resistor and reverse polarity protection diode. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A-11 General Information Switches & Pilot Devices General Information Information About LED Lamps A Light-emitting diodes (LEDs) are P–N junction semiconductors with mechanisms called “junction electro-luminescence.” Appli- cation of direct current results in radiation or emission of a monochromatic light. Different semiconductor materials produce different wavelengths of light as shown below: Green Gallium Phosphide (GaP) 5600 Å Gallium Arsenide Yellow 5800 Å Phosphide (GaAsP) Gallium Arsenide Amber 6300 Å Phosphide (GaAsP) Gallium Arsenide Red 6600Å Phosphide (GaAsP) Infrared Gallium Arsenide (GaAs) 9000 Å Advantages of Using LEDs • LEDs are used when heat generated by incandescent lamps would damage nearby equipment or interfere with a precision process. This is particularly advantageous when multiple lights are grouped. • LEDs can operate at low temperatures which would cause incandescent lamps to fail, since glass cracks dur- ing rapid cooling. • LEDs consume 50 times less power than incandescent lamps, thereby reducing energy consumption. • LEDs last 500 times longer than incandescent lamps. LEDs average a million hours (114 years) while incandes- cent lamps average 2000 hours. • LEDs do not generally “blow out” unless subjected to a severe overvoltage. They exhibit a half-life type dimishment in brightness over time. After 50,000 hours (6 years) of use, IDEC LEDs will retain approximately half of their original intensity. • IDEC’s SUPERBRIGHT LEDs have high visibility. • LEDs require little or no maintenance because of long life and high reliability. IDEC Recommendations For optimum results, especially when using switches and pilot lights in operating environments which are conducive to over- heating, use IDEC LED illuminated units. Transformers are available for use with incandescent illuminated units, which operate at lower voltages to avoid overheating. When IDEC’s L-120L lamp is used, make sure ambient temperatures do not exceed 30˚C (86˚F). If a lamp from another supplier is used, it should be rated for less than 1.8 watts (15mA at 120V AC), with ambient temperatures as stated above. Information About Incandescent Lamps Filament-type incandescent lamps operate within the following parameters. Light output and life expectancy depend on operating voltage. Light output varies to the 3rd or 4th power of the voltage. Life expectancy varies inversely to the 12th power of voltage. In other words, over-voltage of 5% reduces life expectancy by 50%. Under-voltage of 5% doubles life expectancy at the price of light output efŢciency. Inrush current (initial current through the Ţlament) has an adverse effect on life expectancy. Cold resistance (room temperature) will have a more detrimental effect than hot resistance to inrush current. Life expectancy of incandescent lamps can be maxi- mized by reducing occurrences of cold resistance to inrush current. Continued intermittent ţashing will signiŢcantly reduce life expectancy. When using an incandescent lamp with a tungsten Ţla- ment, ţashing will not reduce life expectancy as long as light output does not exceed that of steady burning. When an incandescent lamp must withstand shock and vibration, use low voltage/high amperage (5–6V/60–120mA) lamps. These lamps have a short, thick Ţlament with a high resonant frequency. Provide cooling by using a heat sink, particularly when multiple incandescent lamps are grouped or when air circulation is lim- ited. Make sure ambient temperatures do not exceed 100˚C (212˚F) for maximum life of incandescent lamps. A-12 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Specifications Switches & Pilot Devices Switches & Pilot Devices Selection Guide Comparison: LED vs. Incandescent Lamps Superbright LEDs Incandescent Heat Dissipation Very Low High A Life Expectancy Very Long Short Reliability Very High Low Mechanical Not Susceptible Susceptible to Shock/Vibration Strength Maintenance Negligible Frequent Required Operation at Low Possible Not Possible Temps. Inrush Current Negligible Very Large Voltage Effects InsigniŢcant SigniŢcant on Life Brightness Slightly Less Slightly More Ordering Information 1. IDEC offers assembled and sub-assembled switches and pilot lights for your convenience. In some cases there is a cost difference, with sub-assembled units costing slightly less. Since assembled units are custom made to your order, a couple of days for assembly is added to delivery. To minimize delivery or inventory requirements, it is suggested that switches and pilot lights be ordered as sub-components. 2. When ordering pilot lights or illuminated pushbuttons, make sure to specify the color code in place of the asterisk in the part number, (LED or incandescent lamp included). Spare lamps can be ordered and are listed with sub-assembly components. 3. Accessories, such as locking ring wrench, lens removal tool, and lamp holder, are available to make installation and assembly easier. IDEC recommends using these accessories and is not responsible for damage as a result of using the wrong tool. 4. Marking plates are available for switches and pilot lights which feature a ţat lens. Printed mylar (not included) can also be inserted under lens for labeling pur- poses. 5. Nameplates are available for TW, 7/8" (22mm), HW 7/8" (22mm),and TWTD series, Ş1–13/64" (30mm). For prompt delivery, order standard legends. Custom engraving is also offered for an additional charge. Installation and Operation 1. Use the appropriate lamp holder to remove or install LED or incandescent lamps. Using pliers will damage the lamp. 2. When mounting switches and pilot lights into a panel, use locking ring wrench. Using pliers or tightening excessively will damage the locking ring. 3. A series, 21/64" (8mm), can be mounted on a panel 0.019" (0.5mm) to 0.236" (6mm) thick. 4. TW, 7/8" (22mm) and TWTD series, Ş1–13/64" (30mm), feature an adjustment ring for mounting on a panel 0.038" (1mm) to 0.236" (6mm) thick. Using a name- plate or an anti-rotation ring adds 0.031" (0.8mm) to the panel thickness. 5. When applicable, solder terminals within 20W/5sec or 260˚/3sec without exerting external force to the terminals. Use a non-corrosive resin liquid ţux. 6. The operating voltage for LED units represents a complete DC value. When using a pulsing voltage, such a full-wave rectiŢcation, keep peak currents within the forward current I . Peak currents exceeding I may shorten the life of the LED lamp. f f 7. To avoid a short circuit, never connect NO and NC contacts to different voltages or power sources. 8. Optimum performance of TW and TWTD illuminated pushbuttons, selector switches, and pilot lights is obtained with IDEC LED and incandescent lamps. 9. For maximum life of incandescent lamps (approximately 2000 hours), use within the rated operating voltage. If it is necessary to use a higher voltage, keeping ambient temperature below 30˚C (86˚F)will help prolong the life of an incandescent lamp. If excessive voltage is applied (over 50V), the lamp may blow and the lens holder may pop out. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A-13 Characteristics Safe Break E-Stops World’s Safest Emergency Stop Switches 16mm XA & 22mm XW E-Stops Key features of the XA and XW E-Stops include: • Lead-free (RoHS compliant) • The depth behind the panel is only 48.7mm for 4 contacts (XW Series) A1 • IDEC’s original “Safe Break Action” ensures the contacts open if the contact block is separated from the operator • Pushlock Reset and Push-Pull in the same switch • Direct opening action mechanism (IEC60947-5-5, 5.2, IEC60947-5-1, Annex K) • Safety lock mechanism (IEC60947-5-5, 6.2) • Degree of protection IP65 (IEC60529) • Screw terminal is Ţnger-safe (IP20) • Two button sizes: 40mm and 60mm (XW Series) • Rated Insulation Voltage - 16mm 300V, 22mm 250V • Rated Thermal Current 5A • UL, c-UL Listed, CE marked (XA Series UL recognized) XA & XW Series, The Safe Break Action E-Stops! If the E-Stop is installed With IDEC’s revolution- incorrectly or shifts in ary “Safe Break shipment, the contacts Action,” the NC con- and switch can sepa- tacts will automatically OR rate, which cause the open when the contacts NC contacts to remain are removed from the closed during an emer- operator. This feature gency and the machine places the machine in a to continue running! non-operational state. XA XW Conforming to Standards IEC60947-5-1, EN60947-5-1, IEC60947-5-5, EN60947-5-5, JIS C8201-5-1, UL508, CSA C22.2 No.14 Non-illuminated: -25 to +60˚C Without Freezing Operating Temperature Standard Illuminated: -25 to +55˚C Without Freezing Operating Operating Humidity 45 to 85%RH Without Condensing Conditions Storage Temperature -45 to +80˚C Operating Force Pushlock: 10.5N, Pull Reset: 10N, Turn Reset: 0.16N-m Pushlock: 32N, Pull Reset: 21N, Turn Reset: 0.27N-m Minimum Force to Latch 60N 80N Maximum Travel to Latch 4.0mm Maximum Travel 4.5mm 2 Operating Extremes: 150m/s (15G) Shock Resistance 2 Damage Limits: 1000m/s (100 G) 2 10 to 500Hz, Amplitude 0.35mm Acceleration 50m/s (5G) Vibration Resistance 2 10 to 500Hz, Amplitude 0.35mm Acceleration 50m/s (5G) Mechanical 250,000 Minimum Life Electrical 100,000 Minimum 250,000 or more (24V AC/DC 100mA) Degree of Protection IP65 (IEC60529) Short-Circuit Protection 250V/10A Fuse (Type aM IEC60269-1/IEC60269-2) Terminal Shape Solder Terminal, PCB Terminal M3 Screw Terminal 2 2 Solder/PCB Terminal: 1.25mm Maximum Screw Terminal: 0.75 to 1.25mm Applicable Wire Size (AWG 16 Maximum) (AWG 18 to 16) Soldering 20W/5sec Maximum, 260ºc/3sec Maximum — Recommended Terminal Torque — 0.6 to 1.0N-m Weight (Approx.) 40mm Button: 28 grams 40mm Button: 72 grams, 60mm Button: 81 grams A1-14 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Specifications Switches & Pilot Devices World’s Safest Emergency Stop Switches Safe Break E-Stops XA & XW Series (assembled) Part Numbers: 16mm XA Mushroom Button E-Stop Style Terminal Contacts Part Number 40mm Mushroom 1NO - 1NC XA1E-BV411V-R A1 2NC XA1E-BV402V-R PCB Terminals 1NO-3NC XA1E-BV413V-R 4NC XA1E-BV404V-R 40mm Mushroom 1NO - 1NC XA1E-BV411-R 2NC XA1E-BV402-R Solder Terminals 1NO-3NC XA1E-BV413-R 4NC XA1E-BV404-R Part Numbers: 22mm XW LED Illuminated Mushroom Button E-Stop Style Terminal Contacts Part Number 40mm Mushroom 1NO - 1NC XW1E-LV411Q4M-R 2NC XW1E-LV402Q4M-R Screw Terminals 1NO-3NC XW1E-LV413Q4M-R 4NC XW1E-LV404Q4M-R Illumination is with built-in 24V AC/DC LED. Part Numbers: 22mm XW Mushroom Button E-Stops Style Terminal Contacts Part Number 40mm Mushroom 1NO - 1NC XW1E-BV411M-R 2NC XW1E-BV402M-R Screw Terminals 1NO-3NC XW1E-BV413M-R 4NC XW1E-BV404M-R Part Numbers: 22mm XW Jumbo Mushroom Button E-Stops Style Terminal Contacts Part Number 60mm Mushroom 1NO - 1NC XW1E-BV511M-R 2NC XW1E-BV502M-R Screw Terminals 1NO-3NC XW1E-BV513M-R 4NC XW1E-BV504M-R www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A1-15 ID 3-ø1.7 Holes ø22.3 +0.4 0 R0.8 max. +0.2 ø16.2 0 Safe Break E-Stops World’s Safest Emergency Stop Switches Accessories Part Numbers: Nameplates Part Numbers: 22mm E-Stop Shrouds HWAV–Yellow Plastic Style Part Number A1 HW9Z-KG1-TK2120 Style Part Number ID OD HW9Z-KG2-TK2120 16mm Blank ş60mm HAAV4-0 16mm 60mm XA 16mm “Emergency Stop“ ş60mm HAAV4-27* 16mm 60mm 22mm Blank ş60mm HWAV-0 22mm 60mm 1. Not applicable for 60mm mushroom. XW 2. Applicable for XW (22mm) series only. 40mm 22mm “Emergency Stop“ ş60mm HWAV-27* 22mm 60mm 22mm Blank ş80mm HWAV5-0 22mm 80mm XW 60mm 22mm “Emergency Stop“ ş80mm HWAV5-27* 22mm 80mm *Comes marked “Emergency Stop” as shown. Dimensions XA Dimensions XW Dimensions Panel Thickness 0.5 to 3.7 Panel Thickness 0.8 to 6 Terminal Cover Gasket PC Board Layout XA9Z-VL2 Locking Ring (Bottom View) Terminal Screw Gasket 0.5 19.8 Locking Ring 8.7 2.1 25.8 47.2 Terminal Cover 48.7 32 3.1 30.4 20.6 XW9Z-VL2M 32 6.5 PC Board Terminal Type Solder Terminal Type all dimensions are in mm Connection Diagrams & Panel Cutouts 4NC 1NO-3NC 2NC 1NO-1NC XA XW +0.2 +0.4 TOP TOP TOP TOP ø16.2 0 ø22.3 0 For Standard 12 1 2 3 4 1 2 XW X=Y-50mm Y Y Left Right Left Right Left Right Left Right For Jumbo XW X=Y=70mm X X 2 1 4 3 4 3 4 3 TOP TOP TOP TOP +0.2 1 2 12 34 34 1.7 0 LED LED LED LED Left Right Left Right Left Right Left Right X1 2 1 X2 X1 43 X2 X1 43 X2 X1 43 X2 A1-16 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC 3.2 +0.2 0 OD 8-ø1.2 Holes ø40 ø60 ø40 Switches & Pilot Devices 1 2 12 27.2 19.8 2 1 2 1 8.7 12 1 2 2 1 2 1 19.8 8.7 12 1 2 11.2 2 1 2 1 1 2 12 37 2 1 2 1 +0.2 17.9 0 24.1 +0.4 0 Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - A6 Series A6 Series — Miniature Switches and Pilot Devices: 16mm Key features of the A6 series switches and pilot lights include: • 16mm (5/8") mounting hole • LED illumination A2 • Compact design saves space • Momentary, Maintained, Selectors, and E-Stops • Gold-clad Silver contacts for reliable low level switching • Snap action contacts • IP40 (dustproof) or IP65 (oiltight) versions UL Recognized CSA CertiŢed CertiŢcate No. 2030010305027380 File No.E55996 File No. LR21451 IP40: Dustproof Degree of Protection IP65 Waterproof/Oiltight/Corrosion Resistant Contact Configuration SPDT, DPDT Maximum Voltage 250V AC/DC Thermal Current 3A Minimum Applicable Load 5V AC/DC, 1mA (subject to operating conditions) Contact Material Gold-clad silver Terminal Style .110" Solder/ Quick Connect Operating Temperature LED Type: -25° to +55°C (no freezing) Operating Humidity 45 to 85% RH Contact Resistance 50mΩ maximum (initial value) Insulation Resistance 100MΩ minimum (500V DC megger) Vibration Resistance 10 to 55Hz, amplitude 1.5mm p-p 2 2 Shock Resistance Damage limits: 500m/sec (approx. 50G) Operating extremes: 200m/sec (approx. 20G) 100,000 operations minimum (at full rated load) Electrical Life Maintained: 100,000 operations minimum Mechanical Life Momentary: 1,000,000 operations minimum Selector/Keylock: 250,000 operations minimum Switch Unit: 2,000VAC, 1 min. between live/dead part and terminals of different poles; 1,000V AC, 1 minute between terminals of the same pole; 1,500V AC, 1 minute between Dielectric Strength contact and lamp terminals. Illumination Unit: 2,000VAC, 1 min. between live part/ground 20W/5 seconds or 260°C/3 seconds Soldering Temperature Operating Voltage 24V 120V 240V Resistive — 1.0A 0.5A AC (50/60Hz) Inductive — 0.7A 0.5A Resistive 1.0A 0.2A — DC 0.7A 0.1A — Inductive 5V DC ±5% 6V AC/DC (±10%) 12V AC/DC (±10%) 24V AC/DC (±10%) DC: A, R, W, Y: 6mA Rated Voltage/Current DC: 8mA DC: 8mA G, S: 5mA 8mA AC: A, R, W, Y: 8mA AC: 9mA AC: 9mA G, S: 7mA 1. AC Inductive Load, PF = 0.6 – 0.7; DC Inductive Load, L/R = 7ms. 2. Minimum applicable load (reference value) is 5V AC/DC/1mA (applicable range is subject to the operating conditions and load). 3. LED lamp contains a built-incurrent-limiting resistor and a protection diode. 4. LED’s don’t “burn out.” Luminance is reduced to 50% of initial intensity after being lit for 50,000 hours continuously. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-17 LED Lamp Ratings Contact Ratings Specifications ø16mm - A6 Series Miniature Switches & Pilot Devices AB6 Non-Illuminated Pushbuttons (Assembled) Part Numbers: Non-Illuminated Pushbuttons Part Number Style Contact Momentary Maintained (Latching) Dustproof (IP40) Oiltight (IP65) Dustproof (IP40) Oiltight (IP65) Round 18mm A2 SPDT AB6M-M1-①AB6M-M1P-①AB6M-A1-①AB6M-A1P-① DPDT AB6M-M2-①AB6M-M2P-①AB6M-A2-①AB6M-A2P-① Square 18mm SPDT AB6Q-M1-①AB6Q-M1P-①AB6Q-A1-①AB6Q-A1P-① DPDT AB6Q-M2-①AB6Q-M2P-①AB6Q-A2-①AB6Q-A2P-① Rectangular 18mm x 24mm ① Button Color Code Color Code SPDT AB6H-M1-①AB6H-M1P-①AB6H-A1-①AB6H-A1P-① DPDT AB6H-M2-①AB6H-M2P-①AB6H-A2-①AB6H-A2P-① Black B Green G Red R Round 23.5mm Blue S SPDT AB6M-M1P-M①AB6M-A1P-M①White W – – DPDT AB6M-M2P-M①AB6M-A2P-M① Yellow Y Square 23.5mm SPDT AB6Q-M1P-Q①AB6Q-A1P-Q① – – DPDT AB6Q-M2P-Q①AB6Q-A2P-Q① Rectangular 17.5 X 23.5mm SPDT AB6Q-M1P-H①AB6Q-A1P-H① – – DPDT AB6Q-M2P-H①AB6Q-A2P-H① 1. In place of ①, specify Button Color Code from the table at the right. 2. To order as sub-assembled, see page A2-19. 3. For accessories, see page A2-25. 4. For dimensions, see page A2-27. Part Numbers: AB6-V Pushlock Turn Reset Part Number Shape Operation Contact Remarks Dustproof (IP40) Oiltight (IP65) 23.5mm Round Mushroom Pushlock SPDT AB6M-V1-R AB6M-V1P-R 1. Button available in red only. Turn Reset DPDT AB6M-V2-R AB6M-V2P-R 2. Replacement button: order AB6M-V-R Part Numbers: Buzzer Style Shape Voltage Part Number 12V DC UZ6-11 Round (18mm) 24V DC UZ6-12 A2-18 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Oversize Button Standard Button Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - A6 Series AB6 Non-Illuminated Pushbuttons (Sub-Assembled) Operator + Button = Completed Unit A2 Part Numbers: Operators Part Number Style Contact Operator Round Square Rectangular Non-Illuminated Pushbuttons Momentary AB6M-M100 AB6Q-M100 AB6H-M100 SPDT Maintained AB6M-A100 AB6Q-A100 AB6H-A100 Momentary AB6M-M200 AB6Q-M200 AB6H-M200 DPDT Maintained AB6M-A200 AB6Q-A200 AB6H-A200 Part Numbers: Buttons/Lens Part Number Description Button Dustproof (IP40) Oiltight (IP65) Round AB6M-BK1-①AB6M-BK2-① Square AB6Q-BK1①AB6Q-BK2-① Rectangular ① Button Color Code AB6H-BK1-①AB6H-BK2-①Color Code Black B Green G Round Oversize Red R Blue S – AB6M-BK2-M① White W Yellow Y Square Oversize – AB6Q-BK2-Q① Rectangular Oversize – AB6Q-BK2-H① 1. In place of ①, specify Button Color Code from table on right. 2. Buttons which are rated IP65 include a waterproof rubber gasket. 3. For accessories, see page A2-25. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-19 ø16mm - A6 Series Miniature Switches & Pilot Devices AL6 Illuminated Pushbuttons (Assembled) Part Numbers: LED Illuminated Pushbuttons Part Numbers Voltage Description Style Contact Momentary Maintained (Latching) Dustproof (IP40) Oiltight (IP65) Dustproof (IP40) Oiltight (IP65) A2 Round 18mm diameter AL6M-M14-➁AL6M-M14P-➁AL6M-A14-➁AL6M-A14P-➁24V AC/DC SPDT ±10% DPDT AL6M-M24-➁AL6M-M24P-➁AL6M-A24-➁AL6M-A24P-➁ Square 18mm Standard AL6Q-M14-➁AL6Q-M14P-➁AL6Q-A14-➁AL6Q-A14P-➁24V AC/DC SPDT ±10% DPDT AL6Q-M24-➁AL6Q-M24P-➁AL6Q-A24-➁AL6Q-A24P-➁Lens Rectangular 18mm x 24mm 24V AC/DC SPDT AL6H-M14-➁AL6H-M14P-➁AL6H-A14-➁AL6H-A14P-➁ ±10% DPDT AL6H-M24-➁AL6H-M24P-➁AL6H-A24-➁AL6H-A24P-➁ Round 24mm diameter 24V AC/DC SPDT AL6M-M14P-M➁AL6M-A14P-M➁ – – ±10% DPDT AL6M-M24P-M➁AL6M-A24P-M➁ Square 24 mm Oversize Lens 24V AC/DC SPDT AL6Q-M14P-Q➁AL6Q-A14P-Q➁ – – ±10% DPDT AL6Q-M24P-Q➁AL6Q-A24P-Q➁ Rectangular 18mm x 24mm 24V AC/DC SPDT AL6Q-M14P-H➁AL6Q-A14P-H➁ – – ±10% DPDT AL6Q-M24P-H➁AL6Q-A24P-H➁ 1. In place of ➁, specify Lens/LED Color Code from table below. ➁ Lens/LED Color Code Voltage Code 2. Lamps also available in 5V DC, 6V AC/DC or 12 V AC/DC, Color Code Voltage Code change “4” using voltage/lamp codes (ie AL6M-M13-➁ uses 12V Amber A 5V DC 1 AC/DC LED). Green G 6V AC/DC 2 3. LED lamp is included in unit and contains a current-limiting resistor and a protection diode. (External resistor not required.) Red R 12V AC/DC 3 4. To order as sub-assembled, see page A2-21. Blue S 24V AC/DC 4 5. For accessories, see page A2-25. 6. For dimensions, see page A2-27. White W Yellow Y A2-20 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - A6 Series AL6 Illuminated Pushbuttons (Sub-Assembled) Operator + LED Lamp + Lens = Completed Unit A2 Part Numbers: Operators Part Number Style Contact Operator Round Square Rectangular AL6 Illuminated Pushbuttons Momentary AL6M-M100 AL6Q-M100 AL6H-M100 SPDT Maintained AL6M-A100 AL6Q-A100 AL6H-A100 Momentary AL6M-M200 AL6Q-M200 AL6H-M200 DPDT Maintained AL6M-A200 AL6Q-A200 AL6H-A200 Part Numbers: Lenses Unit Part Number Degree of Dustproof (IP40) Oiltight (IP65) Protection Size Standard Standard Oversize AL6M-LK1-➁AL6M-LK2-➁AL6M-LK2-M➁ Round AL6Q-LK1-➁AL6Q-LK2-➁AL6Q-LK2-Q➁ Square AL6H-LK1-➁AL6H-LK2-➁AL6Q-LK2-H➁ Rectangular 1. In place of ➁, specify Lens Color Code from table below. 2. Lenses which are rated IP65 include a waterproof rubber gasket. 3. For accessories, see page A2-25. Part Numbers: LED Lamps ➁Lens/LED Color Code Appearance Rated Voltage Part Number Color Code 5V DC LATD-5➁Amber A 6V AC/DC LATD-6➁Green G Red R 12V AC/DC LATD-1➁ Blue S 24V AC/DC LATD-2➁ White W In place of ➁, specify LED Color Code from Yellow Y table at left. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-21 ø16mm - A6 Series Miniature Switches & Pilot Devices AL6 Pilot Lights (Assembled) Part Numbers: LED Pilot Lights Part Number Description Voltage Dustproof (IP40) Oiltight (IP65) A2 Round (18mm Lens) 24V AC/DC AL6M-P4-➁AL6M-P4P-➁ Square (18mm Lens) ➁ Lens/LED Color Code Color Code 24V AC/DC AL6Q-P4-➁AL6Q-P4P-➁ Amber A Green G Red R Rectangular (18mm x 24mm Lens) Blue S White W 24V AC/DC AL6H-P4-➁AL6H-P4P-➁ Yellow Y 1. In place of ➁, specify LED/Lens Color Code. 2. Lamps also available in 5V DC, 6V AC/DC or 12 V AC/DC, change “4” using voltage codes (ie AL6M-P3-➁ uses 12V AC/DC lamp). 3. LED Lamp is included and contains built-in current limiting resistor and reverse polarity protection diode. (no external resistor required) 4. To order sub-assembled, see page A2-23. 5. For accessories, see page A2-25. 6. For dimensions, see page A2-27. 7. For one piece pilot lights and/or dome lens pilot lights, see page A5-210. Voltage Code Voltage Code 5V DC 1 6V AC/DC 2 12V AC/DC 3 24V AC/DC 4 A2-22 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - A6 Series AL6 Pilot Lights (Sub-Assembled) Operator + LED Lamp + Lens = Completed Unit A2 Part Numbers: Operators Part Number Style Round Square Rectangular AL6 Pilot Lights AL6M-P00 AL6Q-P00 AL6H-P00 Part Numbers: Lenses Unit Pilot Lights Degree of Dustproof IP40 Oiltight IP65 Protection AL6M-LK1-➁AL6M-LK3-➁ Round AL6Q-LK1-➁AL6Q-LK3-➁ Square AL6H-LK3-➁AL6H-LK1-➁ Rectangular 1. In place of ➁, specify Lens Color Code from table below. 2. Lenses which are rated IP65 include a waterproof rubber gasket. 3. For accessories, see page A2-25. Part Numbers: LED Lamps ➁Lens/LED Color Code Appearance Rated Voltage Part Number Color Code 5V DC LATD-5➁Amber A Green G 6V AC/DC LATD-6➁ Red R 12V AC/DC LATD-1➁ Blue S 24V AC/DC LATD-2➁ White W In place of ➁, specify LED Color Code from Yellow Y table at left. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-23 ø16mm - A6 Series Miniature Switches & Pilot Devices AS6 Selector and Keylock Switches (Assembled) Part Numbers: AS6 Selector Switches and Keylock Switches (2- & 3- Position) Contact Operations (for all selectors) Style Function Selector Switches Keylock Switches Operator Position and Contacts Contact Operation A2 Maintained L R AS6M-2Y2P AS6M-2KT2P①Round Selector Left Right Left NO NC NO NC 2-pos. Spring Return (DPDT) AS6M-21Y2P AS6M-21KT2PB Left Right L Right R Right NO NC NO NC C Maintained AS6M-3Y2PAS6M-3KT2P①Left Right L R Left NO NC NO NC Round Keylock Spring Return C Left Right AS6M-31Y2P AS6M-31KT2P① 3-pos. Right ➛Center L R Center NO NC NO NC (DPDT) Spring Return Right C Left AS6M-32Y2P AS6M-32KT2P① Left➛Center L R Right NO NC NO NC 2-Way C AS6M-33Y2P AS6M-33KT2PD Return➛Center L R①Key Retention Codes Code Description Square Selector Maintained L AS6Q-2Y2P AS6Q-2KT2P①R Key not retained in any position A (removable in all positions) Spring Return to B Key retained in right position only AS6Q-21Y2P AS6Q-21KT2PB L R Right C Key retained in left position only C Key retained in left and right Maintained AS6Q-3Y2P AS6Q-3KT2P① D L R (3 position only) Key retained in center only Spring Return Square Keylock C E AS6Q-31Y2P AS6Q-31KT2P①(3 position only) Right➛Center L R Key retained right and center G (3 position only) Spring Return C AS6Q-32Y2P AS6Q-32KT2P① Left ➛Center L R Key retained left and center H (3 position only) 2-Way C AS6Q-33Y2P AS6Q-33KT2PD Return➛Center L 1. For more information on these R options, contact your IDEC representative. Rectangular L Maintained R AS6H-2Y2P AS6H-2KT2P① Selector 2. Key cannot be removed in a spring return position. Spring Return AS6H-21Y2P AS6H-21KT2PB Right L R C Maintained AS6H-3Y2P AS6H-3KT2P① L R Rectangular Spring Return C Keylock AS6H-31Y2P AS6H-31KT2P① Right ➛Center L R Spring Return C AS6H-32Y2P AS6H-32KT2P① Left➛Center L R 2-Way C AS6H-33Y2P AS6H-33KT2PD Return➛Center L R 1. In place of ①, specify Key Retention Code. See table on right. 2. All models are IP65 and DPDT. 3. Available as assembled units only. 4. For accessories, see page A2-25. 5. For dimensions, see page A2-27. A2-24 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices 3-Position 45° 2-Position 90° 3-Position 45° 2-Position 90° 3-Position 45° 2-Position 90° Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - A6 Series Accessories — A Series: 16mm Appearance Description Used With Part Number Ş 5/8" (16mm) units MT-001 Made of metal. Used for tightening plastic locking ring dur- Locking Ring Ş 31/64" (12mm) AP2M units MT-002 A2 ing installation. Tightening torque should not exceed 3kgf- Wrench cm Ş 13/32" (10mm) AP1M units MT-003 Lens Removal Made of metal. Used for removing lens or button from the All pushbuttons and pilot MT-101 housing lights Tool Lamp Holder Made of rubber. Used for removing and replacing LED All illuminated pushbuttons OR-77 lamps in illuminated units and pilot lights Tool Prevents inadvertent switch operation. IP40 dust-tight Round/Square AL-K6 rated. Rectangular AL-KH6 90 degrees opening maintained Switch Guard Round/Square AL-K6SP Prevents inadvertent switch operation. IP65 oiltight rated 180 degrees opening, spring return Rectangular AL-KH6SP Made of translucent nylon. Fits over and shields the termi- Terminal Cover All 5/8" (16mm) units AL-V6 nals All round units AL-D6 Fits over the lens or button to provide protection from dust. All square units AL-DQ6 Dust Cover (not applicable for oversize lenses or buttons) All rectangular units AL-DH6 Plug-on terminal adaptor with solder terminal AL-C6 Adaptor Socket All 5/8" (16mm) units Plug-on terminal adaptor with PCB terminal AL-C6V Fills unused panel cutouts. Made of nitrile rubber. Push-in installation from front of panel. IP65 (oilt- Rubber AL-B6 Mounting Hole ight) rated. Plug Fills unused panel cutouts. Made of aluminum. Screw-on Aluminum AL-BM6 locking ring from inside of panel. IP65 (oiltight) rated. 5V DC LATD-5➁ 6V AC/DC LATD-6➁Replacement LED with built in current limiting resistor (with all illuminated assemblies). LED Lamps 12V AC/DC LATD-1➁ 24V AC/DC LATD-2➁ Replacement Fastens operators to panel (included with All switches & pilot lights HA9Z-LN Locking Ring all operators). Anti-Rotation Prevents rotation of switches in panel Ring All switches & pilot lights AL6-LP (included with all operators). Round standard AL6M-W Square standard AL6Q-W Replacement Engraving plates to allow legends underneath translucent Rectangular standard AL6H-W Engraving lenses (included with all lenses). Round oversize AL6M-MW Inserts Square/rectangular over- AL6Q-QW size Replacement Pair of keys (#132). All key selectors AS6-SK All key switches use same standard key. Keys 1, In place of ➁ specify color code. A=Amber, W=White, G=Green, Y=Yellow, R=Red, S=Blue. 2. LEDs include built-in current limiting resistor and reverse polarity protection diode. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-25 ø16mm - A6 Series Miniature Switches & Pilot Devices Schematics — A Series: 5/8" (16mm) Terminal Arrangement (Top View) A2 Illuminated Pushbuttons NC NC NO NO COM COM ( + ) ( – ) ( + ) ( – ) Lamp Lamp Lamp Lamp SPDT Contact DPDT Contact (Single-pole/Double Throw) (Double-pole/Double Throw) Non-illuminated Pushbuttons and Selector Switches NC NC NO NO COM COM SPDT Contact DPDT Contact (Single-pole/Double Throw) (Double-pole/Double Throw) IDEC’s Superbright LED Internal Circuit LATD-1,-2,-6 (GS) LED Chip Protective Diode Zener Diode LATD-5 (ARWY) LATD-1,-2,-6 (ARWY) LATD-5 (GS) A2-26 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - A6 Series Dimensions — A Series: 5/8" (16mm) Pushbuttons, Ş 5/8" (16mm) Panel Thickness Terminal Width Rubber Gasket 0.5 to 6mm 2.8 × 0.5t Anti-rotation Ring A2 ø18 Square Round Rectangular 2.5 (TOP) 3 Locking Ring (TOP) ( ) TOP 10.6 5.7 24 18 822 9 9 all dimensions are in mm Large Size Lens Rubber Gasket Panel Thickness Anti-rotation 0.5 to 6mm Ring Round Square Terminal Width 2.8 × 0.5 t Rectangular (TOP) (TOP) Locking Ring 2.5 3 (TOP) 66 1 0.6 9 23.5 0.6 9 0.6 822 15.5 15.5 12.5 all dimensions are in mm Selector Switches, Ş 5/8" (16mm) Gasket Panel Thickness: Terminal Width 0.5 to 6 mm 2.8 × 0.5t Anti-Rotation Ring Rectangular Square Round Locking Ring 2.5 3 ( ) ( ) ( ) TOP TOP TOP 8 1 822 15.5 24 18 all dimensions are in mm Gasket Terminal Width Anti-Rotation Ring Panel Thickness: 0.5 to 6 mm Rectangular Square Round 2.8 × 0.5t (TOP) (TOP) (TOP) Locking Ring 2.5 3 N C N O C 1 822 26 24 18 ø 18 all dimensions are in mm www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-27 ø18 5 5 5 5 5 5 5 5 17.5 18 23.5 18 18 ø23.5 R22 R22 ø16mm - A6 Series Miniature Switches & Pilot Devices Dimensions con’t Panel Thickness: Switch Guard, Ø 5/8" (16mm) 34 0.5 to 5 mm A2 Panel Thickness: 32 0.5 to 5 mm 18 24 Gasket Gasket 14 28 14 28 (90°, 110° opening types) (180° opening type) 19 min. 25 min. Panel Thickness: 34 0.5 to 5 mm Waterproof Gasket 18 24 for Switch Guard Gasket 0.4 14 28 19 min. 25 min. Terminal Sockets Dust Covers AL-C6, 5/8" (16mm), Solder AL-D6, Round AL-DQ6, Square AL-DH6, Rectangular Rubber Gasket Panel Thickness Anti-rotation 0.5 to 6mm❏0.936" (❏24) 1.17" (30) Ring Terminal Width 2.8 × 0.5t❏0.936" Rectangular Locking Ring 2.5 3 ( ) (❏24) TOP 0.293" (7.5) 0.293" (7.5) 0.293" (7.5) 66 1 0.6 9 23.5 0.507" 0.507" 0.507" 822 15.5 (13) (13) (13) 0.012" 0.012" 0.012" Square Round Dust Cover Gasket Dust Cover Gasket Dust Cover Gasket (0.3) (0.3) (0.3) ( ) TOP (TOP) Panel Cut-Outs For Units w/Dust Cover 0.6 9 0.6 15.5 12.5 Round/Square Rectangular +0.007 Ø 0.632" +0.007 +0.2 Ø 0.632" (Ø 16.2 ) +0.2 (Ø 16.2 ) ❏0.936" AL-C6V, Ø 5/8" (16mm), PCB ❏0.936" (❏24) (❏24) 0.012 x 0.059" Terminal: (0.3 x 1.5) 0.098" (2.5) 1.303" (33.4) Ø 0.936" (Ø 24) 0.117" (3) Ø 1.17" (Ø 30) 0.195" (5) 0.195" (5) 0.234" (6) 0.148" 0.638" (16.2) 0.234" 8 - Ø 0.062" (3.8) (6) (Ø 1.6) Holes A2-28 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices 5 5 23.5 23.5 10.5 13 10.5 13 23.5 45.5 min. 26.5 min. (45.5 min. for 180° opening type) 23.5 23.5 10.5 13 10.5 13 ø23.5 17.5 45.5 min. 26.5 min. (45.5 min. for 180° opening type) 33 33 Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - A6 Series Dimensions con’t Marking Plates for Pushbuttons with Standard Size Lens Style Round—AL6M-W Square—AL6Q-W Rectangular—AL6H-W OD 2 A2 Ø a Ø OD ❏OD❏a OD a 1 1 Dimensions Marking Marking a Marking Area 2 Area Area Ş 5/8" (16mm) Ş 0.538"❏0.538" 0.538" x 0.772" Outside (OD) (13.8mm) (13.8mm) (13.8 x 19.8mm) Ş 0.468"❏0.468" 0.468" x 0.702" Marking Area (a) (12mm) (12mm) (12 x 18mm) Engraving must be made on the engraving area within 0.02" (0.5mm) deep. Marking Plates for Pushbutton with Oversize Lens Style Round—AL6M-MW Square/Rectangular—AL6Q-QW Ø a Ø OD ❏OD❏a Dimensions Marking Marking Area Area Outside (OD) Ş 0.491" (12.6mm)❏0.491" (12.6mm) Marking Area (a) Ş 0.429" (11mm)❏0.429" (11mm) Replacing Lens and Marking Plate Removal Ø 5/8" (16mm) Remove the lens holder assembly (lens, marking plate and holder) from the operator by holding the color lens recesses with the lens removal tool (Part Latches No.MT-101) and pulling out. Remove marking plate by pushing the color lens Recess from the rear to disengage the latches. Marking plate must be engraved on the side as shown in the Ţgure on the right. Installation Color For illuminated and non-illuminated pushbuttons: Lens Engraving Marking 1. Insert marking plate inside lens in correct direction Lens Operator Area Plate (For non-illuminated, install marking plate when replacing button). Holder 2. Press color lens on to lens holder to engage latches. 3. Insert lens holder into housing in correct direction. Do not loosen spring on illuminated pushbutton units (except on pilot light units). The marking plate must be engraved on the front side as shown above. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-29 ø16mm - L6 Series Miniature Switches & Pilot Devices L6 Series — Miniature Switches and Pilot Devices Key features of the 5/8” L6 Series include: • 5/8” (16mm) mounting holes • Locking lever removable contact blocks A2 • Solder terminal or PCB terminal options •Available assembled or as sub-components •Worldwide approvals • Incandescent or LED illumination • Snap action contacts CSA CertiŢed UL Recognized File No. LR21451 File No. E55996 Registration No. R9551089 (E-stops) Registration No. J9551458 (all other switches) Registration No. J9650511 (Pilot Lights) Conforming to Standards EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 N0.14 Operation: –25 to +55°C (without freezing), 45 to 85% rh Operating Temperature Storage: -30 to +80°C (without freezing) Vibration Resistance 5 to 55Hz, 1.0 peak-peak amplitude max 2 Operating limit: 100 m/sec (approximately 10G) Shock Resistance 2 Damage limit: 1000 m/sec (approximately 100G) Momentary pushbuttons 2,000,000 operations minimum Mechanical Life All others: 250,000 operations minimum Degree of Protection IP65 (conforming to IEC 60529) Switch unit: between live and ground: 2500 volt AC, 1 minute between terminals of different poles: 2500 volt AC, 1 minute Dielectric Strength between terminals of same pole: 1000 volt AC, 1 minute Illumination unit: between live part and ground: 2500 volt AC, 1 minute Insulation Resistance 100 MΩ minimum (using 500V DC megger) Rated Insulation Voltage 250 V AC/DC Gold Contacts (pcb): 3A Rated Thermal Current Silver Contacts (solder): 5A Contact Resistance 50 Ω maximum initial value Silver Contacts Gold Clad Contacts (Solder Terminals) (PCB terminals) 30V 125V 250V 30V 125V AC resistive - 3A 2A AC inductive - 0.1A Rated Operating Current AC inductive - 2A 1.5A DC resistive 0.1A - DC resistive 2A 0.4A - DC inductive 1A 0.2A - Minimum Recommended Load 5 VAC/DC, 1mA (reference value for silver contacts) Terminal Style 0.110” Solder Tab /PCB Contact Form Snap Action, Double Throw Contact Material Solder Tab: Pure Silver /PCB thermal Gold Plated Silver Electrical Life Momentary pushbuttons: 100,000 operations minimum (1800 operations / hour) (at full load) All others: 100,000 operations minimum (1200 operations / hour) 5V DC LED: 8mA 6V LED: 7mA 6V incandescent: 100 mA Lamp Current Draw 12V LED: 8mA 12V incandescent: 50 mA 24V LED: 8mA 24V incandescent: 25 mA Lamp Life Incandescent: 2000 hours./LED: 50,000 hours. (on pure DC, half-life intensity) Frequency 2 khz ± 500 HZ Amplitude 80db @ 0.1m (at rated voltage) Operating Voltage 6V AC/DC or 12 - 24V AC/DC ± 10% Adjustable Cycle 55 to 600 cycles per minute DC: 7mA Current Draw AC: 20mA Life 1000 hrs. minimum Insulation Voltage 60V AC/DC Operating Temperature -20 to 55 C (no freezing), 45 to 85% rh A2-30 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Buzzer Ratings Lamp Ratings Contact Ratings Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - L6 Series Non-Illuminated Pushbuttons (Assembled) Part Numbers: Non-Illuminated Pushbuttons Button Color Codes Terminal Style Color Code Style Operation Contact Solder Tab PCB Black B Round A2 SPDT LA1B-M1C5-➀LA1B-M1C1V-➀Green G Momentary DPDT LA1B-M1C6-➀LA1B-M1C2V-➀ Red R Blue S SPDT LA1B-A1C5-➀LA1B-A1C1V-➀ Maintained DPDT LA1B-A1C6-➀LA1B-A1C2V-➀ White W Yellow Y Square SPDT LA2B-M1C5-➀LA2B-M1C1V-➀ Momentary DPDT LA2B-M1C6-➀LA2B-M1C2V-➀ SPDT LA2B-A1C5-➀LA2B-A1C1V-➀ Maintained DPDT LA2B-A1C6-➀LA2B-A1C2V-➀ Rectangular SPDT LA3B-M1C5-➀LA3B-M1C1V-➀ Momentary DPDT LA3B-M1C6-➀LA3B-M1C2V-➀ SPDT LA3B-A1C5-➀LA3B-A1C1V-➀ Maintained DPDT LA3B-A1C6-➀LA3B-A1C2V-➀ Oversize Round Flush SPDT HA1B-M1C5-➀HA1B-M1C1V-➀ Momentary DPDT HA1B-M1C6-➀HA1B-M1C2V-➀ SPDT HA1B-A1C5-➀HA1B-A1C1V-➀ Maintained DPDT HA1B-A1C6-➀HA1B-A1C2V-➀ Oversize Round SPDT HA1B-M2C5-➀HA1B-M2C1V-➀Extended Momentary DPDT HA1B-M2C6-➀HA1B-M2C2V-➀ SPDT HA1B-A2C5-➀HA1B-A2C1V-➀ Maintained DPDT HA1B-A2C6-➀HA1B-A2C2V-➀ Oversize Square SPDT HA2B-M1C5-➀HA2B-M1C1V-➀Flush Momentary DPDT HA2B-M1C6-➀HA2B-M1C2V-➀ SPDT HA2B-A1C5-➀HA2B-A1C1V-➀ Maintained DPDT HA2B-A1C6-➀HA2B-A1C2V-➀ Oversize Square SPDT HA2B-M2C5-➀HA2B-M2C1V-➀Extended Momentary DPDT HA2B-M2C6-➀HA2B-M2C2V-➀ SPDT HA2B-A2C5-➀HA2B-A2C1V-➀ Maintained DPDT HA2B-A2C6-➀HA2B-A2C2V-➀ Mushroom SPDT HA1B-M3C5-➀HA1B-M3C1V-➀ Momentary DPDT HA1B-M3C6-➀HA1B-M3C2V-➀ SPDT HA1B-A3C5-➀HA1B-A3C1V-➀ Maintained DPDT HA1B-A3C6-➀HA1B-A3C2V-➀ 1. In place of ➀ specify Button Color Code from table on right. 2. Illuminated (translucent) style lenses also available, specify as such: instead of LA1B-M1C5-➀ use LA1B-M1C5L-➁ in place of ➁ specify Lens Color Code from next page.) 3. PCB terminal models also available with silver contacts (change “1” or “2” to “5” or “6” respectively, ie LA1B-M1C1V-➀ becomes LA1B-M1C5V-➀. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-31 ø16mm - L6 Series Miniature Switches & Pilot Devices Non-Illuminated Pushbuttons (Sub-Assembled) Contact + Safety Lever Lock + Operator + Button = Complete Part A2 Part Numbers: Contacts Part Numbers: Operators Part Numbers: Buttons/Lenses Terminal Style Style Momentary Maintained Style Button Lens Appearance Contacts Round Round Solder PCB Tab LA1L-MO LA1L-AO AB6M-BK2-①AL6M-LK2-➁ SPDT HA-C1 HA-C1V DPDT HA-C2 HA-C2V Square Square LA2L-MO LA2L-AO AB6Q-BK2-①AL6Q-LK2-➁ SPDT HA-C5 HA-C5V DPDT HA-C6 HA-C6V Rectangular Rectangular LA3L-MO LA3L-AO AB6H-BK2-①AL6H-LK2-➁ Part Number: Safety Lever Lock Appearance Part Number Oversize Round Oversize Round Flush HA1B-MO HA1B-AO HA1A-B1-①HA1A-L1-➁* HA9Z-LS Oversize Square Oversize Round Extended ① Button Color Code Color Code HA2B-MO HA2B-AO HA1A-B2-①– Black B Green G Mushroom Oversize Square Flush Red R Blue S HA1B-MOL HA1B-A0L HA2A-B1-①HA2A-L1-➁** White W Yellow Y Oversize Square Extended ➁ Lens Color Code HA2A-B2-①– Color Code 1. In place of ① specify Button Color Amber A Code from table on right. Mushroom Green G 2. In place of ➁ specify Lens Color Code from table on right. Red R HA1A-B3-①HA1A-L3-➁ 3. *requires HA1L-M0 or HA1L-A0 oper- Blue S ator instead of HA1B-M0 or HA1B-A0. Yellow Y 4. **requires HA2L-M0 or HA2L-A0 instead of HA2B-M0 or HA2B-A0. White W A2-32 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Silver Gold Switches & Pilot Devices Y C N S E T Miniature Switches & Pilot Devices ø16mm - L6 Series HA1B/HA1E E-Stop Miniature Switches and Pilot Devices: 5/8"(16mm) Key features of HA1B/HA1E Push lock Turn Reset include: • PCB or Solder Terminals • Quick Release Contact Blocks A2 • Positive Action Contacts •1 or 2 form B (SPST-NC) Contacts • IP65 Protection • 16mm Mounting Hole •Tamper Proof Construction Direct UL Recognized CSA approved Opening File No. DK95-00138 File No. E55996 File No. LR21451 Action 24VDC/2A Contact Ratings 120VAC/3A Part Numbers: Nameplates Contact Form 1 or 2 form B (2-SPST-NC) HAAV–Yellow Plastic Termination PCB or Solder Terminal Contact Material Silver Applicable Standards EN60947-5-1, UL-508, CSA 22.2. No. 14 Rated Insulation Voltage 250V Degree of Protection IP65, when mounted in an enclosure Conditional Short-Circuit Current 50 A (at 250V) 10A 250V Fuse, operation class aM according to IEC269-1 and IEC269-2 &Short-Circuit Protective Device Positive opening travel 3.4mm Minimum force required to achieve Part Number positive opening operation of all 10.3 N (2 form B contacts) Positive Blank HAAV-0 break contacts. Opening Operation Engraved Maximum travel including travel HAAV-27 5.5mm Emergency Stop beyond the minimum travel position Maximum frequency of actuation 1,200 operations/hour Pollution Degree 3 Part Numbers: Positive Action E-Stop Terminal Style Appearance Operation Contact Solder Tab PCB DPST(NC) HA1B-V2E2R HA1B-V2E2VR Button is non- (2 form B) removable, avail- Pushlock/ E-Stop able in red and as Turn Reset Short SPST-NC (1 form B) HA1E-V2S1R complete assembled – Body DPST-NC (2 form B) HA1E-V2S2R unit only. Part Number: Buzzers (IP40) Terminal Style Appearance Operating Voltage Solder/Tab PCB Frequency: 2khz ± 500 hz 6V AC/DC ± 10% LA3Z-1X2 LA3Z-1X2V Amplitude: 80db at 0.1m Beeping: Adjustable from steady Buzzer-Rectangular tone to 600 beeps per minute. 12V to 24 AC/DC ± 10% LA3Z-1X4 LA3Z-1X4V www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-33 G O R P E M E Specifications Ø 60mm ø16mm - L6 Series Miniature Switches & Pilot Devices Pilot Lights (Assembled) ➁ Lens/LED Color Codes Part Numbers: Pilot Lights (LED) Color Code Terminal Style Style Voltage Amber A Solder Tab PCB A2 Round Green G Red R 24V AC/DC LED LA1P-1C04-➁ LA1P-1C04V-➁ Blue S 24VAC/DC Incandescent LA1P-1C07-➁LA1P-1C07V-➁ Yellow Y White W Square Voltage/Lamp Code 24V AC/DC LED LA2P-1C04-➁ LA2P-1C04V-➁ 24V AC/DC Incandescent LA2P-1C07- ➁LAZP-1C07V-➁ Voltage Code 5V DC LED 1 6V AC/DC LED 2 Rectangle 12V AC/DC LED 3 24V AC/DC LED 4 24V AC/DC LED LA3P-1C04-➁ LA3P-1C04V-➁ 120 V AC LED 8 24V AC/DC Incandescent LA3P-1C07-➁ LA3P-1C07V-➁ 6V AC/DC Incandescent 5 12V AC/DC Incandescent 6 24V AC/DC Incandescent 7 Oversize Round 24V AC/DC LED HA1P-1C04-➁HA1P-1C04V-➁ 24V AC/DC Incandescent HA1P-1C07-➁HA1P-1C07V-➁ Oversize Square 24V AC/DC LED HA2P-1C04-➁HA2P-1C04V-➁ 24V AC/DC Incandescent HA2P-1C07-➁HA2P-1C07V-➁ Oversize Round Unibody 24V AC/DC LED HA1P-14-➁ – 24V AC/DC Incandescent HA1P-17-➁ Oversize Square Unibody 24V AC/DC LED HA2P-14-➁ – 24V AC/DC Incandescent HA2P-17-➁ 1. In place of ➁ specify Lens/LED Color Code from table. 2. Lamps also available in 5VDC, 6V AC/DC, 12V AC/DC or 120V AC, change “4” or “7” using Voltage/Lamp Codes (ie LA1P-1C03-➁ uses 12V AC/DC LED). A2-34 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - L6 Series Pilot Lights (Sub-Assembled) Terminals + Safety Lever Lock + Lamp Holder + Lamp + Operator + Lens = Completed Unit A2 Part Numbers: Operators Part Numbers: Lenses Part Numbers: Lamps Style Part Number Style Part Number Part Style Voltage Number Round Round LED LFTD-5➁5V DC LFTD-6➁ 6V AC/DC LA1P-0 AL6M-LK3-➁ 12V AC/DC LFTD-1➁ 24V AC/DC LFTD-2➁ 120 V AC LFTD-H2➁ Incandescent Square Square 6V AC/DC LH-06 12V AC/DC LH-14 LA2P-0 AL6Q-LK3-➁ 24V AC/DC LH-28 In place of ➁ specify LED color Rectangular Rectangular code from table below. LA3P-0 AL6H-LK3-➁ Part Numbers: Terminals Solder Appearance PCB Tab Oversize Round Oversize Round HA-C00 HA-C00V HA1P-0 HA1A-P1-➁ Not required for unibody models. Oversize Square Oversize Square Part Number: Lamp Holder HA2P-0 HA2A-P1-➁ Appearance Part Number HA9Z-AH S In place of ➁ specify lens color Oversize Round Unibody t code. y HA1P-00 Part Number: Safety Lever Lock l Appearance Part Number e Part Number HA9Z- LS Oversize Square Unibody HA2P-00 ➁ Lens/LED Color Codes Color Code Amber A Green G Red R Blue S Yellow Y www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-35 ø16mm - L6 Series Miniature Switches & Pilot Devices Illuminated Pushbuttons (Assembled) Part Numbers: Illuminated Pushbuttons ➁ Lens Color Codes Terminal Style Style Operation Lamp Voltage Contact Color Code Solder Tab PCB SPDT LA1L-M1C54-➁LA1L-M1C14V-➁Amber A A2 Round 24V AC/DC LED DPDT LA1L-M1C64-➁LA1L-M1C24V-➁ Green G Momentary 24V AC/DC SPDT LA1L-M1C57-➁LA1L-M1C17V-➁ Red R Incandescent DPDT LA1L-M1C67-➁LA1L-M1C27V-➁ SPDT LA1L-A1C54-➁LA1L-A1C14V-➁Blue S 24V AC/DC LED DPDT LA1L-A1C64-➁LA1L-A1C24V-➁ Yellow Y Maintained 24V AC/DC SPDT LA1L-A1C57-➁LA1L-A1C17V-➁ White W Incandescent DPDT LA1L-A1C67-➁LA1L-A1C27V-➁ SPDT LA2L-M1C54-➁LA2L-M1C14V-➁ 24V AC/DC LED Square DPDT LA2L-M1C64-➁LA2L-M1C24V-➁ Momentary 24V AC/DC SPDT LA2L-M1C57-➁LA2L-M1C17V-➁ Voltage/Lamp Code Incandescent DPDT LA2L-M1C67-➁LA2L-M1C27V-➁ Voltage Code SPDT LA2L-A1C54-➁LA2L-A1C14V-➁ 24V AC/DC LED DPDT LA2L-A1C64-➁LA2L-A1C24V-➁5V DC LED 1 Maintained 24V AC/DC SPDT LA2L-A1C57-➁LA2L-A1C17V-➁ 6V AC/DC LED 2 Incandescent DPDT LA2L-A1C67-➁LA2L-A1C27V-➁ 12V AC/DC LED 3 SPDT LA3L-M1C54-➁LA3L-M1C14V-➁Rectangular 24V AC/DC LED DPDT LA3L-M1C64-➁LA3L-M1C24V-➁24V AC/DC LED 4 Momentary 24V AC/DC SPDT LA3L-M1C57-➁LA3L-M1C17V-➁ 120V AC LED 8 Incandescent DPDT LA3L-M1C67-➁LA3L-M1C27V-➁ 6V AC/DC Incandescent 5 SPDT LA3L-A1C54-➁LA3L-A1C14V-➁ 24V AC/DC LED DPDT LA3L-A1C64-➁LA3L-A1C24V-➁12V AC/DC Incandescent 6 Maintained 24V AC/DC SPDT LA3L-A1C57-➁LA3L-A1C17V-➁ 24V AC/DC Incandescent 7 Incandescent DPDT LA3L-A1C67-➁LA3L-A1C27V-➁ SPDT HA1L-M1C54-➁HA1L-M1C14V-➁Oversize Round 24V AC/DC LED DPDT HA1L-M1C64-➁HA1L-M1C24V-➁ Momentary 24V AC/DC SPDT HA1L-M1C57-➁HA1L-M1C17V-➁ Incandescent DPDT HA1L-M1C67-➁HA1L-M1C27V-➁ SPDT HA1L-A1C54-➁HA1L-A1C14V-➁ 24V AC/DC LED DPDT HA1L-A1C64-➁HA1L-A1C24V-➁ Maintained 24V AC/DC SPDT HA1L-A1C57-➁HA1L-A1C17V-➁ Incandescent DPDT HA1L-A1C67-➁HA1L-A1C27V-➁ SPDT HA2L-M1C54-➁HA2L-M1C14V-➁Oversize Square 24V AC/DC LED DPDT HA2L-M1C64-➁HA2L-M1C24V-➁ Momentary 24V AC/DC SPDT HA2L-M1C57-➁HA2L-M1C17V-➁ Incandescent DPDT HA2L-M1C67-➁HA2L-M1C27V-➁ SPDT HA2L-A1C54-➁HA2L-A1C14V-➁ 24V AC/DC LED DPDT HA2L-A1C64-➁HA2L-A1C24V-➁ Maintained 24V AC/DC SPDT HA2L-A1C57-➁HA2L-A1C17V-➁ Incandescent DPDT HA2L-A1C67-➁HA2L-A1C27V-➁ SPDT HA1L-M3C54-➁HA1L-M3C14V-➁Mushroom 24V AC/DC LED DPDT HA1L-M3C64-➁HA1L-M3C24V-➁ Momentary 24V AC/DC SPDT HA1L-M3C57-➁HA1L-M3C17V-➁ Incandescent DPDT HA1L-M3C67-➁HA1L-M3C27V-➁ SPDT HA1L-A3C54-➁HA1L-A3C14V-➁ 24V AC/DC LED DPDT HA1L-A3C64-➁HA1L-A3C24V-➁ Maintained 24V AC/DC SPDT HA1L-A3C57-➁HA1L-A3C17V-➁ Incandescent DPDT HA1L-A3C67-➁HA1L-A3C27V-➁ 1. In place of➁ specify lens color code from table at right. 2. Lamps also available in 5V DC, 6V AC/DC, 12 V AC/DC or 120V AC, change “4” or “7” using voltage/lamp codes (ie LA1P-1C03-➁ uses 12V AC/DC LED). 3. PCB terminal models also available with silver contacts (change “1” or “2” to “5” or “6” respectively, ie LA1L-M1C14V-➀ becomes LA1L-M1C54V-➀. A2-36 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - L6 Series Illuminated Pushbuttons (Sub-Assembled) Contacts + Safety Lever Lock + Lamp Holder + Lamp + Operator + Lens = Completed Unit A2 Part Numbers: Operators Part Numbers: Lenses Part Numbers: Lamps Style Momentary Maintained Style Part Number Appearance Voltage Part Number Round LFTD-5➁5V DC LED Round LFTD-6➁6V AC/DC 12V AC/DC LFTD-1➁ 24V AC/DC LFTD-2➁LA1L-MO LA1L-AO AL6M-LK2-➁ 120V AC LFTD-H2➁ Incandescent 6V AC/DC LH-06 12V AC/DC LH-14 24V AC/DC LH-28 Square Square In place of ➁ specify LED color code LA2L-MO LA2L-AO AL6Q-LK2-➁ from table below. Part Numbers: Contacts Terminal Style Rectangular Appearance Contacts Rectangular Solder PCB Tab LA3L-MO LA3L-AO AL6H-LK2-➁ SPDT HA-C10 HA-C10V DPDT HA-C20 HA-C20V Oversize Oversize Round Round HA1L-MO HA1L-A0 HA1A-L1-➁ SPDT HA-C50 HA-C50V DPDT HA-C60 HA-C60V Oversize Oversize Square Square Part Number:Lamp Holder Appearance Part Number HA2L-MO HA2L-AO HA2A-L1-➁ HA9Z-AH Mushroom Mushroom Part Number: Safety Lever Lock Appearance Part Number HA1B-MOL HA1B-AOL HA1A-L3-➁ HA9Z-LS In place of ➁ specify ➁ Lens/LED Color Codes Lens Color Code from Color Code table. Amber A Green G Red R Blue S Yellow Y White W www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-37 Silver Gold ø16mm - L6 Series Miniature Switches & Pilot Devices Selector Switches (Assembled) Part Numbers: Selector Switches Contact Operations (for all selectors) Terminal Style Contact Style Position Operator Position and Solder Tab PCB Contacts Contact Operation A2 L R Maintained DPDT LA1S-2C6 LA1S-2C2V Left Right Left NO NC NO NC Round 2-pos. L R Spring return from right DPDT LA1S-21C6 LA1S-21C2V (DPDT) Right Left Right NO NC NO NC C Maintained L DPDT LA1S-3C6 LA1S-3C2V R Left Right Left C NO NC NO NC Spring return from right L DPDT LA1S-31C6 LA1S-31C2V R Left Right 3-pos. Center C NO NC NO NC (DPDT) Spring return from left L DPDT LA1S-32C6 LA1S-32C2V R Right Left C Right NO NC NO NC 2-Way spring return L DPDT LA1S-33C6 LA1S-33C2V R As viewed from front of L R Maintained DPDT LA2S-2C6 LA2S-2C2V switch. Square L R Spring return from right DPDT LA2S-21C6 LA2S-21C2V C Maintained DPDT LA2S-3C6 LA2S-3C2V L R C Spring return from right L DPDT LA2S-31C6 LA2S-31C2V R C Spring return from left L DPDT LA2S-32C6 LA2S-32C2V R C 2-Way spring Return L DPDT LA2S-33C6 LA2S-33C2V R L R Maintained DPDT LA3S-2C6 LA3S-2C2V Rectangular L R Spring return from right DPDT LA3S-21C6 LA3S-21C2V C Maintained DPDT LA3S-3C6 LA3S-3C2V L R C Spring return from right L DPDT LA3S-31C6 LA3S-31C2V R C Spring return from left L DPDT LA3S-32C6 LA3S-32C2V R C 2-Way spring Return L DPDT LA3S-33C6 LA3S-33C2V R L R Maintained DPDT HA1S-2C6 HA1S-2C2V Oversize Round L R Spring return from right DPDT HA1S-21C6 HA1S-21C2V C 1. All assembled selector switches use Maintained DPDT HA1S-3C6 HA1S-3C2V L R DPDT contacts. C 2. For SPDT contacts see sub-compo- Spring return from right L DPDT HA1S-31C6 HA1S-31C2V R nents on next page. 3. PCB terminal models also available C Spring return from left L DPDT HA1S-32C6 HA1S-32C2V R with silver contacts (change “1” or “2” to “5” or “6” respectively, ie C 2-Way spring Return LA1S-21C2V becomes LA1S-21C6V. L DPDT HA1S-33C6 HA1S-33C2V R A2-38 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices 45˚ 3-Position 90˚ 2-Position 45˚ 3-Position 90˚ 2-Position 45˚ 3-Position 90˚ 2-Position 45˚ 3-Position 90˚ 2 -Position Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - L6 Series Selector Switches (Sub-Assembled) Contacts + Safety Lever Lock + Operator = Complete Part A2 Part Numbers: Operators Style Position Function Part Number Maintained LA1S-2Y Round 2 Spring from right LA1S-21Y Maintained LA1S-3Y Spring from right LA1S-31Y 3 Spring from left LA1S-32Y Spring from both LA1S-33Y Maintained LA2S-2Y Square 2 Spring from right LA2S-21Y Maintained LA2S-3Y Spring from right LA2S-31Y 3 Spring from left LA2S-32Y Spring from both LA2S-33Y Maintained LA3S-2Y Rectangular 2 Spring from right LA3S-21Y Maintained LA3S-3Y Spring from right LA3S-31Y 3 Spring from left LA3S-32Y Spring from both LA3S-33Y Maintained HA1S-2Y Oversize Round 2 Spring from right HA1S-21Y Maintained HA1S-3Y Spring from right HA1S-31Y 3 Spring from left HA1S-32Y Spring from both HA1S-33Y Part Numbers: Contacts Terminal Style Appearance Contacts Solder Tab PCB SPDT HA-C1 HA-C1V HA-C2 DPDT HA-C2V SPDT HA-C5 HA-C5V DPDT HA-C6 HA-C6V 1. All assembled switches listed on previous page use DPDT contacts. 2. SPDT Contacts for use on 2 position selector switch only Part Number: Safety Lever Lock Appearance Part Number HA9Z-LS www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-39 Gold Silver ø16mm - L6 Series Miniature Switches & Pilot Devices Key Switches (Assembled) Contact Operations Part Numbers: Key Switches (for all selectors) Terminal Type Style Operation Contacts Operator Position and Solder Tab PCB Contacts Contact Operation L R Maintained DPDT LA1K-2C6➂LA1K-2C2V➂Left Right Round Left A2 NO NC NO NC Spring 2-pos. L R return from DPDT LA1K-21C6B LA1K-21C2VB (DPDT) Right Left right Right NO NC NO NC C L Maintained R DPDT LA1K-3C6➂LA1K-3C2V➂ Left Right Left NO NC NO NC Spring C return from L R DPDT LA1K-31C6➂LA1K-31C2V➂ Left Right right 3-pos. Center (DPDT) NO NC NO NC Spring C L return from R DPDT LA1K-32C6➂LA1K-32C2V➂ Right Left left Right NO NC NO NC 2-Way C L spring R DPDT LA1K-33C6D LA1K-33C2VD As viewed from front of return switch. L R Maintained DPDT LA2K-2C6➂LA2K-2C2V➂ Square Spring L ➂ Key Retention Option Codes R return from DPDT LA2K-21C6B LA2K-21C2VB right Code Description C Key not retained in any position A Maintained L R DPDT LA2K-3C6➂LA2K-3C2V➂(removable in all positions) B Key retained in right position only Spring C C Key retained in left position only L return from R DPDT LA2K-31C6➂LA2K-31C2V➂ Key retained in left and right right D (3 position only) Spring C Key retained in center only L return from R DPDT LA2K-32C6➂LA2K-32C2V➂E (3 position only) left Key retained right and center G C 2-Way (3 position only) L spring R DPDT LA2K-33C6D LA2K-33C2VD Key retained left and center return H (3 position only) L R Key cannot be removed from Maintained DPDT LA3K-2C6➂LA3K-2C2V➂ Rectangular a spring-return position. Spring L R return from DPDT LA3K-21C6B LA3K-21C2VB right C L Maintained R DPDT LA3K-3C6➂LA3K-3C2V➂ Spring C L return from R DPDT LA3K-31C6➂LA3K-31C2V➂ right Spring C L return from R DPDT LA3K-32C6➂LA3K-32C2V➂ left C 2-Way L spring R DPDT LA3K-33C6D LA3K-33C2VD return L R Maintained DPDT HA1K-2C6➂HA1K-2C2V➂ Oversize Round Spring L R 1. In place of ➂ specify Key Retention return from DPDT HA1K-21C6B HA1K-21C2VB right Code from next page. 2. All assembled key switches have C L Maintained R DPDT HA1K-3C6➂HA1K-3C2V➂DPDT contacts. For SPDT see sub- assembled on next page. Spring C 3. PCB terminal models also avail- L return from R DPDT HA1K-31C6➂HA1K-31C2V➂ able with silver contacts (change right “1” or “2” to “5” or “6” respec- C Spring tively, ie LA1K-2C2V➂ becomes L return from R DPDT HA1K-32C6➂HA1K-32C2V➂ left LA1K-2C6V➂. C 2-Way L spring R DPDT HA1K-33C6D HA1K-33C2VD return A2-40 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices 90 ˚2-Position 90 ˚2-Position 90˚ 2-Position 90 2-Position 45 ˚3-Position 45 ˚3-Position 45 ˚3-Position 45 ˚3-Position Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - L6 Series Key Switches (Sub-Assembled) Contacts + Safety lever lock + Operator = Complete Part A2 Part Numbers: Operators Part Numbers: Contacts Style Positions Operation Part Number Terminal Style Appearance Contacts Solder Maintained LA1K-2➂Round 2 PCB Spring from right LA1K-21B Tab SPDT HA-C1 HA-C1V DPDT HA-C2 HA-C2V Maintained LA1K-3➂ Spring from right LA1K-31➂ 3 Spring from left LA1K-32➂ Spring from both LA1K-33D SPDT HA-C5 HA-C5V DPDT HA-C6 HA-C6V Square Maintained LA2K-2➂ 2 Spring from right LA2K-21B 1. All assembled selectors listed on previous page use DPDT contacts. 2. SPDT contacts are for use on 2 position key Maintained LA2K-3➂switches only. Spring from right LA2K-31➂ 3 Spring from left LA2K-32➂ Spring from both LA2K-33D Part Number: Safety Lever Lock Appearance Part Number Rectangular Maintained LA3K-2➂ 2 Spring from right LA3K-21B HA9Z-LS LA3K-3➂Maintained Spring from right LA3K-31➂ 3 Spring from left LA3K-32➂ Spring from both LA3K-33D ➂ Key Retention Option Codes Code Description Oversize Round Maintained HA1K-2➂Key not retained in any position 2 A Spring from right HA1K-21B (removable in all positions) B Key retained in right position only C Key retained in left position only HA1K-3➂Maintained D Key retained in left and right (3 position only) Spring from right HA1K-31➂ 3 Spring from left E Key retained in center only (3 position only) HA1K-32➂ Spring from both HA1K-33D G Key retained right and center (3 position only) H Key retained left and center (3 position only) Key cannot be removed from 1. In place of ➂ specify key removable code from table a spring-return position. on right. 2. Operator includes two keys. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-41 Silver Gold ø16mm - L6 Series Miniature Switches & Pilot Devices Illuminated Selector Switches Part Numbers: Illuminated Selectors Switches Contact Operations Terminal Style (for all selectors) Style Operation Contact Voltage Solder Tab PCB Operator Position and Contacts Contact Operation L 24V LED LA1F-2C64-➁ LA1F-2C24V-➁R Maintained DPDT 24V Incand. LA1F-2C67-➁LA1F-2C27V- ➁ Left Right A2 Left Spring NO NC NO NC 24V LED LA1F-21C64-➁LA1F-21C24V-➁L R 2-pos. return from DPDT 24V Incand. LA1F-21C67-➁ LA1F-21C27V-➁ right (DPDT) Left Right Right Round C NO NC NO NC 24V LED LA1F-3C64-➁LA1F-3C24V-➁ Maintained L R DPDT 24V Incand. LA1F-3C67-➁ LA1F-3C27V-➁ Right Left Spring C Left NO NC 24V LED LA1F-31C64-➁ LA1F-31C24V-➁ NO NC return from L DPDT R 24V Incand. LA1F-31C67-➁ LA1F-31C27V-➁ right Left Right 3-pos. Spring C Center 24V LED LA1F-32C64-➁LA1F-32C24V-➁(DPDT) NO NC NO NC L return from R DPDT 24V Incand. LA1F-32C67-➁ LA1F-32C27V-➁ left Right Left C 2-Way Right NO NC NO NC 24V LED LA1F-33C64-➁LA1F-33C24V-➁ L spring R DPDT 24V Incand. LA1F-33C67-➁ LA1F-33C27V-➁ return As viewed from front of L 24V LED LA2F-2C64-➁LA2F-2C24V-➁R Maintained DPDT switch. 24V Incand. LA2F-2C67-➁ LA2F-2C27V-➁ Spring 24V LED LA2F-21C64-➁LA2F-21C24V-➁L R return from DPDT 24V Incand. LA2F-21C67-➁ LA2F-21C27V-➁ right➁ Lens/LED Color Code Square C Color Code 24V LED LA2F-3C64-➁LA2F-3C24V-➁ L Maintained R DPDT 24V Incand. LA2F-3C67-➁ LA2F-3C27V-➁ Amber A Green G Spring C 24V LED LA2F-31C64-➁LA2F-31C24V-➁Red R return from L R DPDT 24V Incand. LA2F-31C67-➁ LA2F-31C27V-➁ right Blue S Spring C Yellow Y 24V LED LA2F-32C64-➁LA2F-32C24V-➁ L return from DPDT R 24V Incand. LA2F-32C67-➁ LA2F-32C27V-➁White W left 2-Way C 24V LED LA2F-33C64-➁ LA2F-33C24V-➁ L spring R DPDT Voltage/Lamp Code 24V Incand. LA2F-33C67-➁LA2F-33C27V-➁ return Voltage Code 24V LED LA3F-2C64-➁LA3F-2C24V-➁L R Maintained DPDT 24V Incand. LA3F-2C67-➁ LA3F-2C27V-➁ 5V DC LED 1 Spring 6V AC/DC LED 2 L 24V LED LA3F-21C64-➁LA3F-21C24V-➁R return from DPDT 24V Incand. LA3F-21C67-➁ LA3F-21C27V-➁ right 12V AC/DC LED 3 C Rectangular 24V LED LA3F-3C64-➁LA3F-3C24V-➁24V AC/DC LED 4 Maintained L R DPDT 24V Incand. LA3F-3C67-➁ LA3F-3C27V-➁ 120V AC LED 8 Spring C 24V LED LA3F-31C64-➁LA3F-31C24V-➁ L 6V AC/DC Incandescent 5 return from R DPDT 24V Incand. LA3F-31C67-➁ LA3F-31C27V-➁ right 12V AC/DC Incandescent 6 Spring C 24V LED LA3F-32C64-➁LA3F-32C24V-➁ L return from R DPDT 24V AC/DC Incandescent 7 24V Incand. LA3F-32C67-➁ LA3F-32C27V-➁ left 2-Way C 24V LED LA3F-33C64-➁ LA3F-33C24V-➁ L spring R DPDT 24V Incand. LA3F-33C67-➁ LA3F-33C27V-➁ return L 24V LED HA1F-2C64-➁HA1F-2C24V-➁R Maintained DPDT 1. In place of ➁ specify Lens/LED Color 24V Incand. HA1F-2C67-➁ HA1F-2C27V-➁ Code from table above. Spring L 24V LED HA1F-21C64-➁HA1F-21C24V-➁R 2. Lamps also available in 5V DC, 6V return from DPDT 24V Incand. HA1F-21C67-➁ HA1F-21C27V-➁ right AC/DC or 12 V AC/DC, change “4” C or “7” using voltage/lamp codes (ie Oversize Round 24V LED HA1F-3C64-➁HA1F-3C24V-➁ Maintained L DPDT R 24V Incand. HA1F-3C67-➁ HA1F-3C27V-➁ LA1F-2C63-➁ uses 12V AC/DC LED). Spring C 24V LED HA1F-31C64-➁ HA1F-31C24V-➁3. All switches listed have DPDT con- L return from R DPDT 24V Incand. HA1F-31C67-➁ HA1F-31C27V-➁ right tacts. For SPDT see sub-assembled on next page. Spring C 24V LED HA1F-32C64-➁ HA1F-32C24V-➁ L return from R DPDT 4. PCB terminal models also avail- 24V Incand. HA1F-32C67-➁ HA1F-32C27V-➁ left able with silver contacts (change 2-Way C 24V LED HA1F-33C64-➁HA1F-33C24V-➁“1” or “2” to “5” or “6” respec- L spring DPDT R 24V Incand. HA1F-33C67-➁ HA1F-33C27V-➁ return tively, ie LA1F-2C24V-➁ becomes LA1F-2C64V-➁. A2-42 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices 45˚ 3-Position 90˚ 2-Position 45˚ 3-Position 90˚ 2-Position 45˚ 3-Position 90˚ 2-Position 45˚ 3-Position 90˚ 2-Position Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - L6 Series Illuminated Selector Switches (Sub-Assembled) Contacts + Safety lever lock + Lamp Holder + Lamp + Operator + Lens/Handle = Completed Unit A2 Part Numbers: Operators Part Numbers: Lenses/Handles Style Positions Function Part Number Appearance Part Number Standard Maintained LA1F-20 Round 2 Spring from right LA1F-210 LA1A-F-➁ Maintained LA1F-30 Spring from right LA1F-310 3 Spring from left LA1F-320 Spring from both LA1F-330 Oversize Maintained LA2F-20 Square 2 Spring from right LA2F-210 HA1A-F-➁ Maintained LA2F-30 Spring from right LA2F-310 3 Spring from left LA2F-320 Spring from both LA2F-330 In place of ➁ specify Lens Color Code from table. Maintained LA3F-20 Rectangular 2 Spring from right LA3F-210 Maintained LA3F-30 Spring from right LA3F-310 Part Number: Safety Lever Lock 3 Spring from left LA3F-320 Appearance Part Number Spring from both LA3F-330 Oversize Round Maintained HA1F-20 2 Spring from right HA1F-210 HA9Z-LS Maintained HA1F-30 Spring from right HA1F-310 3 Spring from left HA1F-320 Spring from both HA1F-330 Part Numbers: Contacts Part Number: Lamp Holder Terminal Style Appearance Part Number Appearance Solder Contacts PCB Tab HA9Z-AH SPDT HA-C10V HA-C1 DPDT HA-C2 HA-C20V SPDT HA-C50 HA-C50V DPDT HA-C60 HA-C60V Part Numbers: Lamps Appearance Voltage Part Numbers 1. All assembled selectors on previous pages use DPDT con- LED 5V DC LFTD-5➁ tacts. SPDT contacts are for use only on two position 6V AC/DC LFTD-6➁ selectors. 12V AC/DC LFTD-1➁ 24V AC/DC LFTD-2➁ 120V AC LFTD-H2➁ ➁ LED/Lens Color Code Incandescent Color Code 6V AC/DC LH-06 12V AC/DC LH-14 Amber A 24V AC/DC LH-28 Green G Red R Blue S In place of ➁ specify LED Color Code Yellow Y from table. White W www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-43 Silver Gold ø16mm - L6 Series Miniature Switches & Pilot Devices Pushbutton Selectors (Assembled) Part Numbers: Pushbutton Selectors① Button Color Code Terminal Style Color Code Style Solder Tab PCB Black B Green G A2 2 Position HA1R-2C6-①HA1R-2C2V-① Red R Blue S Yellow Y 3 Position HA1R-3C6-①HA1R-3C2V-① 1. In place of ① specify Button Color Code. 2. PCB terminal models also available with silver contacts (change “1” or “2” to “5” or “6” respectively, ie HA1R-2C2V-① becomes HA1R-2C6V-①). Contact Operation Operator Position Style Left Center Right Normal Depressed Normal Depressed Normal Depressed Left Right Right 2 Position Left Right Left Right Left –– NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC Left Right Right Left Right Left Right Left Right Left Blocked 3 Position NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC Lever Switch (Assembled) Part Numbers: Lever Switches Terminal Type Style Operation Contacts Solder Tab PCB U Maintained DPDT LA1T-2C6 LA1T-2C2V D U Spring return from top DPDT LA1T-21C6 LA1T-21C2V D U Spring Return from bottom DPDT LA1T-22C6 LAIT-22C2V D U Maintained C DPDT LA1T-3C6 LA1T-3C2V D PCB terminal models also available U with silver contacts (change “1” or Spring return from top C DPDT LA1T-31C6 LA1T-31C2V “2” to “5” or “6” respectively, ie D U LA1T-2C2V becomes LA1T-2C6V). Spring return from bottom C DPDT LA1T-32C6 LA1T-32C2V D U Spring return from both C DPDT LA1T-33C6 LA1T-33C2V D Contact Operation Operator Position & Contact Operation Contacts Down Center Up Left Left Right Right 2-pos. Maintained NO NC NO NC NO NC NO NC (DPDT) Spring from Top Left Right Left Right 2-pos Spring Return NO NC NO NC NO NC NO NC (DPDT). from Bottom Left Right Right As viewed from front of Left Right Left 3-pos. All models NO NC NO NC NO NC NO NC switch. (DPDT) NONC NO NC A2-44 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices 3-Position 2-Position Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - L6 Series Accessories Part Specifications Part Number Notes Used for tightening the plastic locking ring when installing the L6 series unit on a panel. Ring Wrench Made of metal MT-001 Tightening torque should not exceed 9kgf cm when tightening a locking ring. A2 Made of rubber. Used for removing and Lamp Holder Tool replacing LED and incandescent lamps in Rubber tool used for replacing LED and OR-44 (Made of Rubber) illuminated units. incandescent lamps. Used for removing the lens or button Lens Removal Tool For Illuminated pushbuttons and pilot lights. MT-101 from the housing. 5V DC LFTD-5➁ 6V AC/DC LFTD-6➁ T 1-3/4 miniature ţange base. In place of ➁ specify LED LED Lamp 12V AC/DC LFTD-1➁ Color Code (see page A2-43). 24V AC/DC LFTD-2➁ 120V AC LFTD-H2➁ 6V AC/DC LH-06 Incandescent Lamp 12V AC/DC LH-14 0.5W, T 1-3/4 miniature ţange base 24V AC/DC LH-28 Round/Square AL-K6 90 degrees open- Prevents inadvertent switch operation. IP40 dust-tight ing maintained rated. Rectangular AL-KH6 Switch Guard Round/Square AL-K6SP 180 degrees Prevents inadvertent switch operation. IP65 oiltight opening, spring Rectangular AL-KH6SP rated. return Oversize Round/Sq HA9Z-K1 For round units AL-D6 Provides extra level of sealing for “front-panel” portion Dust-proof Cover For square units AL-DQ6 of switches. (Not applicable for units with oversize lenses or buttons). For rectangular units AL-DH6 All removable H6-VL2 contacts Made of white Terminal Cover Covers terminals to prevent possible electric shock. nylon Unibody Pilot Lights H6-PVL Fills unused panel cutouts. Made of nitrile rubber. Rubber AL-B6 Push-in installation from front of panel. IP65 (oiltight) rated. Mounting Hole Plug Fills unused panel cutouts. Made of aluminum. Screw- Aluminum AL-BM6 on locking ring from inside of panel. IP65 (oiltight) rated. AS6-SK for LA1K (#132) Replacement Keys Pair of keys. for HA1K (#231) KG9Z-SK Round AL6M-W Square AL6Q-W Replacement Rectangle AL6H-W Engraving Inserts Oversize Round HA9Z-P1-W Oversize Square HA9Z-P2-W Mushroom HA9Z-P13-W Replacement All models HA9Z-LN Locking Ring L6 standard AL6-LP Replacement Prevents rotation of switches in panel. Anti-Rotation Ring (included with all assembled switches) L6 oversize HA9Z-LP Replacement Applicable to round oversize selectors only HA9Z-HC1-① Selector Inserts① = (G, R, S, W, Y) Replacement HA9Z-LS Safety Lever Lock www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-45 RO.61" (15.5mm) LOCK ø16mm - L6 Series Miniature Switches & Pilot Devices Dimensions Non -Illuminated Pushbuttons (LA*B) 0.11 (2.8) A2 0.24 (6.0) 0.98 0.71 0.71 (24.8) (18.0) (18.0) 0.27 0.35 1.39 0.94 0.71 (6.8) 0.38 0.71 (9.0) (35.4) (24.0) (18.0) (9.6) (18.0) Emergency Stop Switch (HA1B) Rubber Washer Panel Thickness Stopper 0.02"-0.24" (0.5~6.0mm) Locking Ring PCB Terminal 0.34" + (8.7mm) NC NC - 0.21" 0.53" 0.20" (5.4mm) 0.41" (13.5mm) 0.43" ø0.70" (5.2mm) (10.5mm) (11mm) (17.8mm) 0.62" ø0.83" (15.8mm) (21mm) 0.98" (25mm) 1.42" (36mm) Emergency Stop Switch (HA1E) - Short Body Style Buzzer (LA3Z) 0.11 (2.8) 0.98 0.71 (24.8) (18.0) 0.24 (6.0) 0.35 0.35 1.39 0.94 (9.0) 0.62 (9.0) (35.4) (24.0) (15.7) Pilot Lights (LA*P) 0.11 (2.8) 0.24 (6.0) 0.98 0.71 0.71 (24.8) (18.0) (18.0) 0.27 0.35 1.39 0.94 0.38 0.71 0.71 (6.8) (9.0) (35.4) (24.0) (9.6) (18.0) (18.0) A2-46 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Ø 0.98" (24.9mm) Switches & Pilot Devices Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - L6 Series Dimensions con’t Illuminated Pushbuttons (LA*L) 0.11 (2.8) A2 0.24 (6.0) 0.98 0.71 0.71 (24.8) (18.0) (18.0) 0.27 0.35 1.39 0.94 0.38 0.71 0.71 (6.8) (9.0) (35.4) (24.0) (9.6) (18.0) (18.0) Key Switches (LA*K) 0.11 (2.8) 0.24 (6.0) 0.98 0.71 0.71 (24.8) (18.0) (18.0) 0.27 0.35 1.39 0.94 .98 0.71 (6.8) 0.71 (9.0) (35.4) (24.0) (24.9) (18.0) (18.0) Selector Switches (LA*S) 0.11 (2.8) 0.24 (6.0) 0.98 0.71 0.71 (24.8) (18.0) (18.0) 0.27 0.35 1.39 0.94 0.66 0.71 (6.8) 0.71 (9.0) (35.4) (24.0) (16.8) (18.0) (18.0) Panel Cut-Out PCB Layout (except for Buzzer and E-Stop) PCB Pins Acess Hole 0.03 for Locking Lever (0.8) 0.36 0.24 (9.3) (6.0) 0.20 Ş0.05 (5.0) (1.2) 0.42 (10.7) 0.20 0.04 (5.0) (1.0) 0.20 0.27 0.06 (5.0) (6.8) (1.5) 0.94 0.25 (24.0) (6.4) HA1B E-Stop PCB Mounting Pattern 0.21" 0.21" (5.3mm) (5.3mm) 0.34" 0.21" (8.7mm) (5.4mm) www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-47 Ø 0.05" (1.2mm) ø16mm - L6 Series Miniature Switches & Pilot Devices Dimensions con’t Oversize Flush Pushbutton and Pilot Lights A2 1.02 [25.9] 0.43 [11.0] 0.94 [24.0] Oversize Extended Non-Illuminated Pushbutton 0.59 [15.1] Oversize Unibody PIlot Lights 1.48 [37.5] Mushroom Pushbuttons 1.18 [30.0] ÿ1.18 [ÿ30.0] 0.79 [20.0] Oversize Selector Switch 0.94 [23.8] ÿ0.94 [ÿ23.8] 0.77 [19.5] A2-48 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices X2 X2 X1 C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC NO NC Switches & Pilot Devices R22 Miniature Switches & Pilot Devices ø16mm - L6 Series Dimensions con’t Oversize Key Switch A2 1.54 [39.0] Lever Switch 0.94 [23.8] Terminal Configurations Non Illuminated Pushbutton Pilot Lights Illuminated Pushbuttons Buzzer Lamp Terminal Lamp Terminal (+) (+) Input Terminal (X1) Lamp Terminal Input Lamp Terminal Buzzer (–) Terminal (–) Sound (X2) Switch Steady Slow Quick AL-KH6SP AL-K6SP .94 .71 .51 .51 (24.) (18) (13) 1.34 (13) (34) .93 .93 Panel Thickness: (23.5) .20 max. (5 max) (23.5) 1.30 .41 (33) .41 (10.5) 1.79 (10.5) 1.79 (45.5) (45.5) .98 .75 (25) (19) AL-DH6 AL-D6 AL-DQ6 1.18 .94 ş24 (30) (24) .94" .94 (24) .51 .30 (13) .30 (7.5) .51 (7.5) (13) .51 (13) .01 Water-proof Gasket .01 .01 Water-proof Gasket (0.3) Water-proof Gasket .30 (0.3) (0.3) (7.5) www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-49 C NO NC C NO NC CN NOC NO NC C NO NC CN NOC X2 X2 X1 X2 X2 X1 CN NOC CN NOC X2 X2 X1 X1 ø16mm - L6 Series Miniature Switches & Pilot Devices Dimensions con’t H6-VL2 AL-B6 AL-BM6 1.85 TOP Marking Side (47) .24 .08 (6) A2 (2) .47 .10 (12) (2.5) .69 (17.6) .16 .70 .65 Gasket Locking Ring (4) (16.5) .59 .83 (18) (15) (21) LED Lamp Internal Circuit LED Chip Protective Diode Zener Diode A2-50 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices .70 (17.8) Switches & Pilot Devices Miniature Switches & Pilot Devices ø16mm - L6 Series General Instructions Pushbutton Assembly Lamp Installation Lamps can be replaced in two ways: A2 1. If contacts are accessible (or pushbutton not installed in a panel) then it is easiest to Ţrst remove the contacts from the operator. This will allow easy access to the lamp/lamp-holder assembly. Grab lamp, depress slightly, and turn counter clockwise. Lamp can then be removed by pushing it back through the lamp holder. 2. If contacts are not accessible, then the lamp can be replaced by Ţrst removing the lens from the operator. Just pull lens straight out either with a Ţngernail or optional lens removal tool (MT-101). Lamp/lamp- holder assembly can then be removed with lamp removal tool (OR-44). Insert lamp removal tool through operator, depress slightly, turn counter clockwise, then pull lamp/lamp-holder assembly out. Lamp can then be removed by pushing it back through the lamp holder. Engraving Lenses All buttons and lenses can be engraved directly on the outside surface. Illuminated lenses also allow for engraving on a plate that is underneath the colored section of the lens. Remove the colored section of the lens Latches by pulling on the edge while simultaneously unhooking it from the Recess latches on the lens holder. The marking plate will then be accessible. It can then be engraved or a thin marked insert (such as mylar or paper) can be sandwiched between the marking plate and colored section of Engraving Area the lens. Color Lens Marking Plate Lens Holder Panel Mounting Before any unit can be mounted into a panel, the contact block must be removed. Slide metal locking lever and pull contact off. Loosen and remove the locking ring and square anti-rotation ring from the operator and insert operator through panel cutout from the front of the panel. Slide on anti-rotation ring and tighten locking ring, using locking ring wrench (MT-001). Slide contact block onto operator, observing TOP marking on both parts. Slide metal locking lever in direction indicated by LOCK. The yellow plastic safety lever lock can then be snapped onto the locking lever; this will prevent vibration or maintenance actions from releasing the contact from the operator. PCB Mounting Being able to separate the contacts from the operator allows for assem- bly of the front panel components (operator and lens) to be performed in tandem with the PC board assembly and soldering. For applications where multiple rows of pushbuttons are mounted closely together, or where other components may obstruct access to the contact locking lever, be sure to include access holes in the PC board (refer to PC board layout dimensions for location). Also be sure to allow for space above and to the side of contact to ensure that no components block the con- tact block locking lever. PC board pins are designed to rest on the PCB, take this into consideration to ensure that pins do not short closely spaced traces. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-51 ø22mm - HW Series Oiltight Switches & Pilot Devices HW Series — 22mm IEC Style Global Pushbuttons A3 HW: The Best Engineered Switch in the World Key features include: IDEC’s HW switches are “The best engineered switch in the world” for a reason. Carrying the CE mark, UL, CSA, CCC (Chinese), and TUV approv- als, these switches are designed for use in almost any part of the world. • Locking lever removable contact blocks • Finger-safe IP20 contacts as standard, other terminal Complete with Ţnger-safe contact blocks offering IP20 protection, these styles available 7/8" (22mm) switches include illuminated and non-illuminated •Tamperproof construction pushbuttons, pilot lights, selector switches, and emergency stop • All E-stops meet EN418 and are compliant with SEMI switches. S2 standards •Worldwide approvals All switches also incorporate mechanically keyed safety locking levers, • Easy to assemble ensuring correct installation and maintaining safety in high-vibration •Available assembled or as sub-components applications. • Choice of black plastic or metallic front bezels • Incandescent or LED illumination •Transformer or full voltage • Slow make double break self cleaning contacts File No. LR92374 File No. E68961 Certificate No. Registration No. R9551089 (E-stops) 2005010305145656 Registration No. R50054316 (Dual Pushbuttons) Registration No. J9650511 (Pilot Lights) Registration No. J9551458 (all other switches) A3-52 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Conforming to Standards EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14 Approvals CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) UL: pushbuttons and selector switches: A600 File No. E68961 File No. LR92374 Certificate No. pilot lights and illuminated pushbuttons, direct supply 2005010305145656 pilot lights and illuminated pushbuttons with integral transformer A3 (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) TÜV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer Registration No. R9551089 (E-stops) Registration No. J9551458 (all other switches) (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) Registration No. J9650511 (Pilot Lights) Operating Temperature Operation: –25 to +50°C (without freezing), Storage: –40 to +70°C (without freezing) 2 Vibration Resistance 10 to 55Hz, 98m/sec (10G) conforming to IEC6068-2-6 2 Shock Resistance 980m/sec (100G) conforming to IEC6068-2-7 Electric Shock Protection Class 0 conforming to IEC60536 Degree of Protection IP65 (from front of the panel) (conforming to IEC60529) IP20 (Type HW-F contact block) (conforming to NEMA ICS6-110) NEMA 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (from front of panel) Mechanical Life Momentary pushbuttons: 5,000,000 (900 operations per hour), All other switches: 500,000 Pollution Degree (conforming to IEC60947-1) 3 for switches not using a transformer, 2 for switches using a transformer AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB) Rated Operational Characteristics DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC) DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB) Rated Insulation Voltage 600V Rated Switching Over-Voltage Less than 4kV, conforming to IEC60947-1 Rated Impulse Withstanding Voltage 4kV for contact circuit, 2.5kV for lamp circuit Rated Thermal Current 10 Amp Minimum Switching Capacity 5 mA at 3V AC/DC Contact Operation Slow break NC or NO, self-cleaning 5.5mm to 10mm travel to latch 45N minimum force to latch Positive Action Operation 10mm maximum travel (Emergency Stops with NC contacts) 1,800 operations per hour maximum for a Pushlock Turn Reset 900 operations per hour maximum for a Push-Pull Flush and extended pushbuttons—with 1NO or 1NC contact: 6.2±2N (momentary), 7.0±2N (main- Operating Force tained) Additional contacts—1NO or 1NC: +3.2N (momentary), + 3.3N (maintained) Terminal Referencing Conforming to CENELEC EN50005 Recommended Terminal Torque 0.8 N m (7.1 in lb.) External Short-Circuit Protection 10A 250V fuse conforming to IEC60269-1 Applicable Wire Size Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG Contact Resistance Initial contact resistance of 50mΩ or less Contact Gap 4mm (NO and NC), 2mm (NO-EM and NC-LB) Horsepower Rating Reference Value: 1/4 HP @ 120V (1ş non-reversing), 1HP @ 240V (3ş non-reversing) Electrical Reliability MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA) Incandescent: 1 W Lamp Ratings LEDs: 6V/17mA max, 12V & 24V/11mA max, 120 & 240V/10mA max 40 A (40 ms) Maximum Inrush Current Silver (gold plated contacts available - contact IDEC) Contact Material Contact Block Type HW-C/HW-F /HW-G Pushbuttons Rated Insulation Voltage 600V Illuminated Pushbuttons Selector Switches Rated Continuous Current 10A Illuminated Selector Switches Pushbutton Selectors Contact Ratings by Utilization Category AC-15 (A600) IEC 60947-5-1 DC-13 (P600) Operational Voltage 24V 48V 50V 110V 220V 440V AC AC-12 Control of resistive loads & solid state loads 10A — 10A 10A 6A 2A 50/60 AC-15 Control of electromagnetic loads (> 72VA) 10A — 7A 5A 3A 1A Hz Operational Current DC-12 Control of resistive loads & solid state loads 8A 5A — 2.2A 1.1A — DC DC-13 Control of electromagnets 5A 2A — 1.1A 0.6A — 1. For dimensions, see page A3-100. 2. For life expectancy derating curves, see page A3-105. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-53 Characteristics Contact Ratings Specifications ø22mm - HW Series Oiltight Switches & Pilot Devices Non-Illuminated Pushbuttons (Assembled) Part Numbers: Non-Illuminated Pushbuttons Contact Plastic Bezel Metal Bezel Style Momentary Maintained Momentary Maintained Round Flush A3 1NO HW1B-M1F10-➀HW1B-A1F10-➀HW4B-M1F10-➀HW4B-A1F10-➀ 1NC HW1B-M1F01-➀HW1B-A1F01-➀HW4B-M1F01-➀HW4B-A1F01-➀ 1NO-1NC HW1B-M1F11-➀HW1B-A1F11-➀HW4B-M1F11-➀HW4B-A1F11-➀ 2NO HW1B-M1F20-➀HW1B-A1F20-➀HW4B-M1F20-➀HW4B-A1F20-➀ 2NC HW1B-M1F02-➀HW1B-A1F02-➀HW4B-M1F02-➀HW4B-A1F02-➀ 2NO-2NC HW1B-M1F22-➀HW1B-A1F22-➀HW4B-M1F22-➀HW4B-A1F22-➀ Round Extended 1NO HW1B-M2F10-➀HW1B-A2F10-➀HW4B-M2F10-➀HW4B-A2F10-➀ 1NC HW1B-M2F01-➀HW1B-A2F01-➀HW4B-M2F01-➀HW4B-A2F01-➀ 1NO-1NC HW1B-M2F11-➀HW1B-A2F11-➀HW4B-M2F11-➀HW4B-A2F11-➀ 2NO HW1B-M2F20-➀HW1B-A2F20-➀HW4B-M2F20-➀HW4B-A2F20-➀ 2NC HW1B-M2F02-➀HW1B-A2F02-➀HW4B-M2F02-➀HW4B-A2F02-➀ 2NO-2NC HW1B-M2F22-➀HW1B-A2F22-➀HW4B-M2F22-➀HW4B-A2F22-➀ 29mm Mushroom Head 1NO HW1B-M3F10-➀HW1B-A3F10-➀HW4B-M3F10-➀HW4B-A3F10-➀ 1NC HW1B-M3F01-➀HW1B-A3F01-➀HW4B-M3F01-➀HW4B-A3F01-➀ 1NO-1NC HW1B-M3F11-➀HW1B-A3F11-➀HW4B-M3F11-➀HW4B-A3F11-➀ 2NO HW1B-M3F20-➀HW1B-A3F20-➀HW4B-M3F20-➀HW4B-A3F20-➀ 2NC HW1B-M3F02-➀HW1B-A3F02-➀HW4B-M3F02-➀HW4B-A3F02-➀ 2NO-2NC HW1B-M3F22-➀HW1B-A3F22-➀HW4B-M3F22-➀HW4B-A3F22-➀ 40mm Mushroom Head 1NO HW1B-M4F10-➀HW1B-A4F10-➀HW4B-M4F10-➀HW4B-A4F10-➀ 1NC HW1B-M4F01-➀HW1B-A4F01-➀HW4B-M4F01-➀HW4B-A4F01-➀ 1NO-1NC HW1B-M4F11-➀HW1B-A4F11-➀HW4B-M4F11-➀HW4B-A4F11-➀ 2NO HW1B-M4F20-➀HW1B-A4F20-➀HW4B-M4F20-➀HW4B-A4F20-➀ 2NC HW1B-M4F02-➀HW1B-A4F02-➀HW4B-M4F02-➀HW4B-A4F02-➀ 2NO-2NC HW1B-M4F22-➀HW1B-A4F22-➀HW4B-M4F22-➀HW4B-A4F22-➀ ① Button Color Code Color Code Black B 60mm Jumbo Mushroom Head 1NO HW1B-M5F10-➀* Green G 1NC HW1B-M5F01-➀* 1NO-1NC HW1B-M5F11-➀* —— — Red R 2NO HW1B-M5F20-➀* 2NC HW1B-M5F02-➀* Blue S 2NO-2NC HW1B-M5F22-➀* White W Square Flush 1NO HW2B-M1F10-➀HW2B-A1F10-➀ Yellow Y 1NC HW2B-M1F01-➀HW2B-A1F01-➀ 1NO-1NC HW2B-M1F11-➀HW2B-A1F11-➀ Grey N* —— 2NO HW2B-M1F20-➀HW2B-A1F20-➀ * Grey is available for 2NC HW2B-M1F02-➀HW2B-A1F02-➀ 2NO-2NC HW2B-M1F22-➀HW2B-A1F22-➀Round Flush models only. Square Extended 1NO HW2B-M2F10-➀HW2B-A2F10-➀ 1NC HW2B-M2F01-➀HW2B-A2F01-➀ 1NO-1NC HW2B-M2F11-➀HW2B-A2F11-➀ —— 2NO HW2B-M2F20-➀HW2B-A2F20-➀ 2NC HW2B-M2F02-➀HW2B-A2F02-➀ 2NO-2NC HW2B-M2F22-➀HW2B-A2F22-➀ 1. In place of ➀, specify the Button Color Code. 2. *Jumbo mushroom available only in red, green, black, and yellow. 3. For nameplates and accessories, see page A3-96 and A3-98. 4. For dimensions, see page A3-100. 5. For sub-assembly part numbers, see page A3-56. A3-54 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Non-Illuminated Pushbuttons (Partial-Assemblies) Contact Assembly + Operator Assembly + Complete Switch A3 Part Numbers: Operator Assemblies Style Plastic Bezel Metal Bezel Style Plastic Bezel Metal Bezel Square Flush Momentary HW2B-M1-➀– Round Flush Momentary HW1B-M1-➀HW4B-M1-➀ Maintained HW2B-A1-➀– Square Extended Momentary HW2B-M2-➀– Maintained HW1B-A1-➀HW4B-A1-➀ Maintained HW2B-A2-➀– Round Extended 1. In place of ➀, specify the Button Color Code from table below. 2. For complete sub-assemblies, see page A3-56. Momentary HW1B-M2-➀HW4B-M2-➀ Part Numbers: Contact Assemblies Maintained HW1B-A2-➀HW4B-A2-➀ Style Contacts Part Number Standard Fingersafe Contacts 1NO HW-CBF10 1NC HW-CBF01 29mm Mushroom 1NO/1NC HW-CBF11 Head 2NO HW-CBF20 Momentary HW1B-M3-➀HW4B-M3-➀ 2NC HW-CBF02 2NO/2NC HW-CBF22 Spring Up Terminal Contacts 1NO HW-CB10 1NC HW-CB01 1NO/1NC HW-CB11 2NO HW-CB20 Maintained HW1B-A3-➀HW4B-A3-➀ 2NC HW-CB02 2NO/2NC HW-CB22 40mm Mushroom Head Momentary HW1B-M4-➀HW4B-M4-➀ ① Button Color Code Color Code Black B Green G Maintained HW1B-A4-➀HW4B-A4-➀ Red R Blue S White W 60mm Mushroom Head Yellow Y Grey N* Momentary HW1B-M5-➀*– *Grey is available for round flush only. *60mm mushroom available in red, green, black and yellow only. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-55 ø22mm - HW Series Oiltight Switches & Pilot Devices Non-Illuminated Pushbuttons (Sub-Assembled) Adaptor & Safety Anti-Rotation Contact Blocks + + + Operator + Button = Complete Part Lever Lock Ring A3 Part Numbers: Buttons Part Numbers: Operators Part Numbers: Contact Blocks Style Part Number Style Plastic Bezel Metal Bezel Style 1NO 1NC Round Flush Round Flush/Extended Standard Fingersafe Contacts (IP20) Momentary HW1B-M0 HW4B-MO HW-F10 HW-F01 HW1A-B1-➀ HW-F10R HW-F01R (early make) (late break) Round Extended HW1B-A0 HW4B-AO Maintained Spring-Up Terminal Contacts HW1A-B2-➀ HW-G10 HW-G01 Ş 29mm Mushroom Ş 29mm Ş 40mm Mushroom HW-G10R HW-G01R Mushroom Cap (early make) (late break) Momentary HW1B-M0L HW4B-MOL HW1A-B3-➀ Exposed Screw Terminal Contacts Ş40mm Maintained HW1B-A0L HW4B-AOL HW-C10 HW-C01 Mushroom Cap HW-C10R HW-C01R HW1A-B4-➀ (early make) (late break) Ş 60mm Jumbo Mush- room Square Flush Dummy Block Momentary HW1B-M5-➀* – HW2A-B1-➀ TW-DB Square Flush Extended Square Extended Momentary HW2B-M0 – HW2A-B2-➀ HW2B-A0 Maintained – 1. All assembled part numbers in catalog include standard (HW-F...) contacts. Part Number: Contact 2. Assembled units with spring-up terminals 1. In place of ➀, specify the Button Color Block Mounting Adaptor (HW-G...) can be ordered by removing an “F” Code from table below. (safety lever lock included) from the part number (Ex. HW1B-M1F11-R 2. *60mm mushroom operator includes Part becomes HW1B-M111-R). non-removable button (available in red, Style Number 3. Units with exposed screw terminals (HW-C...) black, green and yellow only). must be ordered as sub-components. 3. For nameplates and accessories, see 4. All contacts (including non-fingersafe versions) page A3-96. are UL, CSA, and IEC compliant and carry the 4. For dimensions, see page A3-100. HW-CB2C CE mark. ① Button Color Code Color Code Color Code Part Numbers: Anti-Rotation Ring Black B White W 1. Used to mount con- Appearance Part Number tact blocks to oper- Green G Yellow Y ator (first pair only). † Red R Grey N 2. IDEC strongly recommends HW9Z-RL using the safety lever lock Blue S (included) to prevent heavy vibration or maintenance per- Use with notched panel cutout 1. HW1B-M5 available only in black, red sonnel from inadvertently to prevent unit rotation. green and yellow. unlocking contacts. † 2. Grey available for round flush only. A3-56 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Y C N S E T Oiltight Switches & Pilot Devices ø22mm - HW Series Emergency Stop Pushbuttons (Assembled) Part Numbers: Non-Illuminated Emergency Stop Pushbuttons Part Numbers: Nameplates Style Contact Plastic Bezel Metal Bezel HWAV–Yellow Plastic † † HW1B-Y2F10-➀HW4B-Y2F10-➀Ş 40mm Head Push–Pull 1NO † † HW1B-Y2F01-➀HW4B-Y2F01-➀1NC † † 1NO-1NC A3 HW1B-Y2F11-➀HW4B-Y2F11-➀ 2NC † † HW1B-Y2F02-➀HW4B-Y2F02-➀ 2NO † † HW1B-Y2F20-➀HW4B-Y2F20-➀ Ş 29mm Head Pushlock Turn Reset 1NO HW1B-V3F10-R* HW4B-V3F10-R* 1NC HW1B-V3F01-R* HW4B-V3F01-R* 1NO-1NC HW1B-V3F11-R* HW4B-V3F11-R* 2NO HW1B-V3F20-R* HW4B-V3F20-R* 2NC HW1B-V3F02-R* HW4B-V3F02-R* † † HW1B-V4F10-➀HW4B-V4F10-➀Ş 40mm Head Pushlock Turn Reset 1NO Style Part Number † † HW1B-V4F01-➀HW4B-V4F01-➀1NC † † 1NO-1NC HW1B-V4F11-➀HW4B-V4F11-➀60mm Diameter † HWAV-27 2NO † † HW1B-V4F20-➀HW4B-V4F20-➀“Emergency Stop” 2NC † † HW1B-V4F02-➀HW4B-V4F02-➀ HWAV-0 60mm Diameter Blank Ş 40mm Head EMO Pushlock Turn 1NO HW1B-V4F10-R-EMO-2 HW4B-V4F10-R-EMO-2 80mm Diameter Reset 1NC HW1B-V4F01-R-EMO-2 HW4B-V4F01-R-EMO-2 HWAV5-27 “Emergency Stop“ 1NO-1NC HW1B-V4F11-R-EMO-2 HW4B-V4F11-R-EMO-2 (for jumbo mushroom use) 2NO HW1B-V4F20-R-EMO-2 HW4B-V4F20-R-EMO-2 2NC HW1B-V4F02-R-EMO-2 HW4B-V4F02-R-EMO-2 † HWAV-27 comes marked “Emergency Stop” as shown Ş 40mm Head Pushlock Key Reset in drawing. 1NO HW1B-X4F10-R* HW4B-X4F10-R* 1NC HW1B-X4F01-R* HW4B-X4F01-R* Part Numbers: E-Stop Shrouds 1NO-1NC HW1B-X4F11-R* HW4B-X4F11-R* Style Part Number 2NO HW1B-X4F20-R* HW4B-X4F20-R* 2NC HW1B-X4F02-R* HW4B-X4F02-R* Ş 60mm Head Pushlock Turn Reset HW1B-V5F10-R* HW9Z-KG1-TK2120 1NO HW1B-V5F01-R* 1NC 1NO-1NC HW1B-V5F11-R* – 2NO HW1B-V5F20-R* 2NC HW1B-V5F02-R* Ş 40mm Head Unibody Pushlock HW9Z-KG2-TK2120 Turn Reset 1NO-1NC HW1E-BV4F11-R* 2NC – HW1E-BV4F02-R* 1NO-2NC HW1E-BV412R-TK2093-1** Not applicable for 60mm mushroom. Part Numbers: Illuminated Emergency Stop Pushbuttons Illumination Style Contact Part Number Type Terminal Numbering (Unibody only) Models Terminal Number 1NO-1NC HW1E-LV4F11QD-R*-➂ 2NC HW1E-LV4F02QD-R*-➂ LED 1NO-1NC NO = .3/.4, NC = .1/.2 2NC (with active lamp circuit) HW1E-TV4F02QD-R*-➂ 1NO-1NC (with active lamp circuit) HW1E-TV4F11QD-R*-➂ 2NC NC = 11/12, NC = 21/22 1NO-1NC HW1E-LV4F11Q-R*-➂ HW1E-L 2NC HW1E-LV4F02Q-R*-➂Lamp + = X2, Lamp - = X1 Incandescent HW1E-T 1NO-1NC (with active lamp circuit) HW1E-TV4F11Q-R*-➂ 2NC (with active lamp circuit) HW1E-TV4F02Q-R*-➂ 1. * Available in Red only. ➂ Full Voltage Code 2. † Available in red or yellow (insert color code in place of ➀) Voltage Code 3. In place of ➂, specify Full Voltage Code. 4. With single unit construction, the positive action contacts are integrated in the body of the switch. This provides an 6VAC/DC 6V extra degree of safety and reliability for critical emergency stop functions. 12VAC/DC 12V 5. In the illuminated version, the light is independent of the switch action (except active lamp circuit model). 24VAC/DC 24V 6For nameplates and accessories, see page A3-96. 7For dimensions, see page A3-100. 8. For sub-assembly part numbers, see next page. 9. All HW series E-stops comply with EN418, the IEC “E-Stop Addendum to the Low Voltage Directive,” this includes “tamper proof” operation whereby a change of contact state is not possible by “teasing” or “floating” the operator. 10. “Active Lamp Circuit” consists of a built-in Normally Open contact in series with the lamp. This allows the lamp to illuminate only when the button is pressed and eliminates the need for external jumpering. 11. Replacement Lens is HWLV-LENSR. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-57 G O R P E M E Ø 60mm ø22mm - HW Series Oiltight Switches & Pilot Devices Emergency Stop Pushbuttons (Partial-Assemblies) Contact Assembly + Anti-Rotation Ring + Operator Assembly + Complete Switch A3 Part Numbers: Anti-Rotation Ring Part Numbers: Operators Appearance Part Number Style Plastic Bezel Metal Bezel Ş 29mm Head Pushlock Turn Reset HW9Z-RL HW1B-V3R* HW4B-V3R* Use with notched panel cutout to prevent unit rotation. Ş 40mm Head Pushlock Turn Reset red HW1B-V4R HW4B-V4R yellow HW1B-V4Y HW4B-V4Y Ş 40mm Head EMO Pushlock Turn Reset HW1B-V4R-EMO-2* HW4B-V4R-EMO-2* Ş 40mm Head Push-Pull red HW1B-Y2R HW4B-Y2R yellow HW1B-Y2Y HW4B-Y2Y Ş 40mm Head Pushlock Key Reset HW1B-X4R* HW4B-X4R* Ş 60mm Head Pushlock Turn Reset HW1B-V5R* – 1. *Available in red only. 2. All HW Series Emergency Stop operators include non-removable color caps. 3. All HW Series Emergency Stop operators comply with EN418 “E-Stop Addendum to the Low Voltage Directive” (when used as part of a complete HW series Emergency Stop Pushbutton). 4. All HW series Emergency Stop switches comply with SEMI S2 standards. Part Numbers: Contact Assemblies Style Contacts Part Number Standard Fingersafe Contacts 1NO HW-CBF10 1NC HW-CBF01 1NO/1NC HW-CBF11 2NO HW-CBF20 2NC HW-CBF02 2NO/2NC HW-CBF22 Spring Up Terminal Contacts 1NO HW-CB10 1NC HW-CB01 Gold contact option is available for spring-up termi- 1NO/1NC HW-CB11 nals. Add suffix “MAU” to end of part number. For 2NO HW-CB20 example, HW-CB20 becomes HW-CB20-MAU. 2NC HW-CB02 2NO/2NC HW-CB22 A3-58 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Emergency Stop Pushbuttons (Sub-Assembled) Contact Blocks + Adaptor & Safety Lever Lock + Anti-Rotation Ring + Operator = Complete Part A3 Part Numbers: Emergency Stop Operators Part Numbers: Contact Blocks Style Plastic Metal Description Part Number Ş 29mm Head Pushlock Turn Reset 1NO 1NC Standard Fingersafe (IP20) HW1B-V3R* HW4B-V3R* HW-F10 HW-F01 HW-F10R HW-F01R Ş 40mm Head Pushlock Turn Reset (early make) (late break) red HW1B-V4R HW4B-V4R HW-G10 HW-G01 Spring-Up Terminal Contacts yellow HW1B-V4Y HW4B-V4Y HW-G10R HW-G01R Ş 40mm Head EMO Pushlock Turn Reset (early make) (late break) HW-G10-MAU HW-G01-MAU HW1B-V4R-EMO-2* HW4B-V4R-EMO-2* (gold con- (gold con- tacts) tacts) Exposed Screw Terminal Contacts HW-C10 HW-C01 Ş 40mm Head Push-Pull red HW1B-Y2R HW4B-Y2R HW-C10R HW-C01R (early make) (late break) yellow HW1B-Y2Y HW4B-Y2Y Dummy Block Ş 40mm Head Pushlock Key Reset TW-DB HW1B-X4R* HW4B-X4R* Ş 60mm Head Pushlock Turn Reset 1. All assembled part numbers in catalog include standard (HW-F...) contacts. (except unibody) HW1B-V5R* – 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) must be 1. *Available in red only. ordered as sub-components. 2. All Emergency Stop Buttons are non-removable from 4. All contacts (including exposed screw) are UL, CSA, the operator. and IEC compliant and carry the CE mark. Part Number: Contact Block Mounting Adaptor (safety lever lock included) Part Numbers: Anti-Rotation Ring Style Part Number Appearance Part Number HW9Z-RL HW-CB2C Use with notched panel cutout to prevent unit rotation. 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance person- nel from unlocking contacts. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-59 ø22mm - HW Series Oiltight Switches & Pilot Devices Emergency Stop Stations Part Numbers: Emergency Stop Stations Description Contacts Plastic Bezel Metal Bezel 1NO-1NC HW1X-BV411-R* HW4X-BV411-R* Ş 40mm Pushlock Turn Reset A3 2NC HW1X-BV402-R* HW4X-BV402-R* 1NO-1NC HW1X-BV311-R* HW4X-BV311-R* Ş 29mm Pushlock Turn Reset 2NC HW1X-BV302-R* HW4X-BV302-R* 1NO-1NC HW1X-BY411-R* HW4X-BY411-R* Ş 40mm Push-Pull Reset 2NC HW1X-BY402-R* HW4X-BY402-R* 1NO-1NC HW1X-BX411-R* HW4X-BX411-R* Ş 40mm Pushlock Key Reset 2NC HW1X-BX402-R* HW4X-BX402-R* 1.* Available in Red only. 2. Maximum of two contact blocks. 3. Available as completed unit only. 4. Box is supplied with yellow top and black bottom only. Part Numbers: Nameplates for Emergency Stop Stations Part Number NSA-Aluminum Color Blank Engraved 34mm Black NSA-0 NSA-*R Red NSA-0R NSA-*R 1. In place of * please insert the word, letters, or numbers you would like engraved. For standard engravings, see page A3-96. 2. For specifications on engravings, please consult factory. Part Numbers: Base Mount Contact Blocks Configuration Part Number 1NO HW-S10 1NC HW-S01 Part Numbers: Plug Adaptors Type Part Number G1/2 HW9Z-G PG16 HW9Z-PG Panel Mount Dimensions A 58 58 58 HW1B-V4R Box Cover Mouting Screws Box Cover Box Base 2-ø4.6 A3-60 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC ø 25.5mm Switches & Pilot Devices 70 36mm 58 42.4 Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Pilot Lights (Assembled) Part Numbers: Pilot Lights Style Plastic Bezel Metal Bezel Round Flush Full Voltage HW1P-1FQ➃-➁-➂HW4P-1FQ➃-➁-➂ HW1P-1FH2➃-➁HW4P-1FH2➃-➁120V AC A3 Transformer 240V AC HW1P-1FM4➃-➁HW4P-1FM4➃-➁ 480V AC HW1P-1FT8➃-➁HW4P-1FT8➃-➁ DC-DC Converter* 110V DC – HW1P-1D2➃-➁ (Full Voltage type shown) Dome Full Voltage HW1P-2FQ➃-➁-➂HW4P-2FQ➃-➁-➂ HW1P-2FH2➃-➁HW4P-2FH2➃-➁120V AC Transformer 240V AC HW1P-2FM4➃-➁HW4P-2FM4➃-➁ 480V AC HW1P-2FT8➃-➁HW4P-2FT8➃-➁ DC-DC Converter* 110V DC – HW1P-2D2➃-➁ (Full Voltage type shown) Square Flush Full Voltage HW2P-1FQ➃-➁-➂– HW2P-1FH2➃-➁120V AC Transformer 240V AC HW2P-1FM4➃-➁– 480V AC HW2P-1FT8➃-➁ DC-DC Converter* 110V DC HW2P-1D2➃-➁– (Transformer type shown) Jumbo Dome LED HW1P-5Q4-➁ Full Voltage** – 24V AC/DC Incandescent HW1P-5Q7-➁ 1. In place of ➁, specify the Lens/LED Color Code. 2. In place of ➂specify the Full Voltage Code from table below. 3. In place of ➃ specify Lamp Type Code. 4. *DC-DC convertor voltage input from 90-140V DC, comes with spring up terminals only. 5. **Available with spring up terminals and 24V only. 6. For nameplates and accessories, see page A3-96. 7For dimensions, see page A3-100. ➁ Lens/LED Color Code ➃ Lamp Type Code ➂ Full Voltage Code Color Code Lamp Code Voltage Code Amber A Incandescent Blank 6V AC/DC 6 Green G LED D 12V AC/DC 12 Red R 24V AC/DC 24 Blue S 120V AC (LED only) 120 White W 240VAC (LED only) 240 Y Yellow www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-61 ø22mm - HW Series Oiltight Switches & Pilot Devices Pilot Lights (Partial-Assemblies) Full Voltage Models Operator/Lens + Lamp = Complete Pilot Light A3 Part Numbers: Operator/Lens Part Numbers: Lamps Style Plastic Bezel Metal Bezel Type Voltage Part Number Round Flush 6V AC/DC LSTD-6➁ LED 12V AC/DC LSTD-1➁ HW1P-1FQ0-➁HW4P-1FQ0-➁ 24V AC/DC LSTD-2➁ 120V AC LSTD-H2➁ Dome 240V AC LSTD-M4➁ 6.3V AC/DC IS-6 Incandescent HW1P-2FQ0-➁HW4P-2FQ0-➁ 12V AC/DC IS-12 24V AC/DC IS-24 Square Flush 30V AC/DC IS-30 1. In place of ➁, specify the LED Color Code HW2P-1FQ0-➁– from table on previous page. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. 1. In place of ➁, specify the Lens Color Code from table on previous page. 2. Operator/Lens assembly for use with standard transformers only6, not spring up terminal type. Transformer Models Transformer/Lamp + Operator/Lens = Complete Part Numbers: Operator/Lens Part Numbers: Transformer/Lamp Style Plastic Bezel Metal Bezel Item Voltage Part Number Round Flush 120V AC with LED HW-FH2-➁ 240V AC with LED HW-FM4-➁ HW1P-1F0-➁HW4P-1F0-➁ 480V AC with LED HW-FT8-➁ 120V AC with Incandescent HW-FH2 Dome 240V AC with Incandescent HW-FM4 480V AC with Incandescent HW-FT8 HW1P-2F0-➁HW4P-2F0-➁ 1. In place of ➁, specify the LED Color Code from table on previous page. Square Flush 2. All transformers have a 6V AC secondary voltage. 3. LED/Lamp supplied with transformer partial assembly. HW2P-1F0-➁– In place of ➁, specify the Lens Color Code from table on previous page. A3-62 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Pilot Lights (Sub-Assembled) Transformer* + Lamp + Anti-Rotation Ring + Operator + Lens = Complete Part A3 * Not applicable to full voltage units. Part Numbers: Operators Part Numbers: Transformer Units Style Type Plastic Bezel Metal Bezel Style Voltage Part Number Round Flush LED/Incandescent HW-FH20 120V AC Standard HW-MH20 (with spring up terminals)* HW1P-1FQ0 HW4P-1FQ0 Full Voltage HW-FM40 240V AC Spring Up HW-MM40 (with spring up terminals)* HW1P-1Q0 HW4P-1Q0 Terminals HW-FT80 480V AC HW-RT80 (with spring up terminals)* Standard HW1P-10 HW4P-10 110V DC** HW-RD0 (with spring up terminals)* (6V secondary voltage) Transformer 1. *To use spring up terminal type, must use transformer type Spring Up HW1P-100 – Terminals operator designed for spring up transformer. (HW1P-10 shown) 2. ** DC-DC converter voltage input from 90-140V DC. Dome Standard HW1P-2FQ0 HW4P-2FQ0 Part Numbers: Lamps ➁ Lens/LED Full Voltage Type Voltage Part Number Color Code Spring Up HW1P-2Q0 HW4P-2Q0 Terminals 6V AC/DC LSTD-6➁Color Code LED 12V AC/DC LSTD-1➁Amber A Standard HW1P-20 HW4P-20 24V AC/DC LSTD-2➁Green G Transformer Spring Up 120V AC LSTD-H2➁Red R HW1P-200 – Terminals (HW1P-20 shown) 240V AC LSTD-M4➁Blue S Standard HW2P-1FQ0 White W Incandescent 6.3V AC/DC IS-6 Square Flush Full Voltage – Yellow Y 12V AC/DC IS-12 Spring Up HW2P-1Q0 Terminals 24V AC/DC IS-24 Standard HW2P-10 – 1. In place of ➁, specify the LED Color Code. Transformer (HW2P-10 shown) 2. The LED contains a current-limiting resistor Spring Up HW2P-100 – and reverse polarity protection diodes. Terminals Part Numbers: Anti-Rotation Ring 1. Transformer type requires separate transformer & lamp. Appearance Part Number Must select correct transformer bases on standard or spring up terminal type. Use 6V lamps or LEDs. Use with notched panel 2. Full voltage type only requires lamp. HW9Z-RL cutout to prevent unit rotation. Part Numbers: Lenses Style Part Number Jumbo Dome Pilot Light Replacement Parts Description Item Part Number LED Type HW1P-5Q0 Round/Flush HW1A-P1-➁ Replacement Jumbo Incandesccent Dome Operator HW1P-5Q7 Type* Replacement Jumbo HW1A-P5① Dome HW1A-P2-➁ Dome Lens① = (A, G, R, S, W, Y) Polycarbonate Lens Replacement LED HW9Z-PP5C Diffusing Lens Square/ HW2A-P1-➁ Flush Replacement LED Lamps LSTDB-2①LED Lamp for HW Jumbo Dome① = (A, G, R, S, W, Y) In place of ➁, specify the Lens Color Code. *Operator comes with incandescent bulb. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-63 ø22mm - HW Series Oiltight Switches & Pilot Devices Illuminated Pushbuttons (Assembled) Part Numbers: Illuminated Pushbuttons Plastic Bezel Metal Bezel Style Description Contacts Momentary Maintained Momentary Maintained Flush 1NO HW1L-M1F10Q➃-➁-➂HW1L-A1F10Q➃-➁-➂HW4L-M1F10Q➃-➁-➂HW4L-A1F10Q➃-➁-➂ A3 1NC HW1L-M1F01Q➃-➁-➂HW1L-A1F01Q➃-➁-➂HW4L-M1F01Q➃-➁-➂HW4L-A1F01Q➃-➁-➂ Full Voltage 1NO-1NC HW1L-M1F11Q➃-➁-➂HW1L-A1F11Q➃-➁-➂HW4L-M1F11Q➃-➁-➂HW4L-A1F11Q➃-➁-➂ 2NO HW1L-M1F20Q➃-➁-➂HW1L-A1F20Q➃-➁-➂HW4L-M1F20Q➃-➁-➂HW4L-A1F20Q➃-➁-➂ 120V AC 1NO-1NC HW1L-M1F11H2➃-➁HW1L-A1F11H2➃-➁ HW4L-M1F11H2➃-➁HW4L-A1F11H2➃-➁ 120V AC 2NO HW1L-M1F20H2➃-➁HW1L-A1F20H2➃-➁HW4L-M1F20H2➃-➁HW4L-A1F20H2➃-➁ Transformer 240V AC 1NO-1NC HW1L-M1F11M4➃-➁HW1L-A1F11M4➃-➁HW4L-M1F11M4➃-➁HW4L-A1F11M4➃-➁ 240V AC 2NO HW1L-M1F20M4➃-➁HW1L-A1F20M4➃-➁HW4L-M1F20M4➃-➁HW4L-A1F20M4➃-➁ Extended 1NO HW1L-M2F10Q➃-➁-➂HW1L-A2F10Q➃-➁-➂HW4L-M2F10Q➃-➁-➂HW4L-A2F10Q➃-➁-➂ 1NC HW1L-M2F01Q➃-➁-➂HW1L-A2F01Q➃-➁-➂HW4L-M2F01Q➃-➁-➂HW4L-A2F01Q➃-➁-➂ Full Voltage 1NO-1NC HW1L-M2F11Q➃-➁-➂HW1L-A2F11Q➃-➁-➂HW4L-M2F11Q➃-➁-➂HW4L-A2F11Q➃-➁-➂ 2NO HW1L-M2F20Q➃-➁-➂HW1L-A2F20Q➃-➁-➂HW4L-M2F20Q➃-➁-➂HW4L-A2F20Q➃-➁-➂ 120V AC 1NO-1NC HW1L-M2F11H2➃-➁HW1L-A2F11H2➃-➁HW4L-M2F11H2➃-➁HW4L-A2F11H2➃-➁ 120V AC 2NO HW1L-M2F20H2➃-➁HW1L-A2F20H2➃-➁HW4L-M2F20H2➃-➁HW4L-A2F20H2➃-➁ Transformer 240V AC 1NO-1NC HW1L-M2F11M4➃-➁HW1L-A2F11M4➃-➁HW4L-M2F11M4➃-➁HW4L-A2F11M4➃-➁ 240V AC 2NO HW1L-M2F20M4➃-➁HW1L-A2F20M4➃-➁HW4L-M2F20M4➃-➁HW4L-A2F20M4➃-➁ Extended 1NO HW1L-MF2F10Q➃-➁-➂HW1L-AF2F10Q➃-➀-➂HW4L-MF2F10Q➃-➁-➂HW4L-AF2F10Q➃-➀-➂with Full Shroud 1NC HW1L-MF2F01Q➃-➁-➂HW1L-AF2F01Q➃-➀-➂HW4L-MF2F01Q➃-➁-➂HW4L-AF2F01Q➃-➀-➂ Full Voltage 1NO-1NC HW1L-MF2F11Q➃-➁-➂HW1L-AF2F11Q➃-➀-➂HW4L-MF2F11Q➃-➁-➂HW4L-AF2F11Q➃-➀-➂ 2NO HW1L-MF2F20Q➃-➁-➂HW1L-AF2F20Q➃-➀-➂HW4L-MF2F20Q➃-➁-➂HW4L-AF2F20Q➃-➀-➂ 120V AC 1NO-1NC HW1L-MF2F11H2➃-➁HW1L-AF2F11H2➃-➁HW4L-MF2F11H2➃-➁HW4L-AF2F11H2➃-➁ 120V AC 2NO HW1L-MF2F20H2➃-➁HW1L-AF2F20H2➃-➁HW4L-MF2F20H2➃-➁HW4L-AF2F20H2➃-➁ Transformer 240V AC 1NO-1NC HW1L-MF2F11M4➃-➁HW1L-AF2F11M4➃-➁HW4L-MF2F11M4➃-➁HW4L-AF2F11M4➃-➁ 240V AC 2NO HW1L-MF2F20M4➃-➁HW1L-AF2F20M4➃-➁HW4L-MF2F20M4➃-➁HW4L-AF2F20M4➃-➁ 40mm Mushroom 1NO HW1L-M4F10Q➃-➁-➂HW1L-A4F10Q➃-➁-➂HW4L-M4F10Q➃-➁-➂HW4L-A4F10Q➃-➁-➂ Head 1NC HW1L-M4F01Q➃-➁-➂HW1L-A4F01Q➃-➁-➂HW4L-M4F01Q➃-➁-➂HW4L-A4F01Q➃-➁-➂ Full Voltage 1NO-1NC HW1L-M4F11Q➃-➁-➂HW1L-A4F11Q➃-➁-➂HW4L-M4F11Q➃-➁-➂HW4L-A4F11Q➃-➁-➂ 2NO HW1L-M4F20Q➃-➁-➂HW1L-A4F20Q➃-➁-➂HW4L-M4F20Q➃-➁-➂HW4L-A4F20Q➃-➁-➂ 120V AC 1NO-1NC HW1L-M4F11H2➃-➁HW1L-A4F11H2➃-➁HW4L-M4F11H2➃-➁HW4L-A4F11H2➃-➁ 120V AC 2NO HW1L-M4F20H2➃-➁HW1L-A4F20H2➃-➁HW4L-M4F20H2➃-➁HW4L-A4F20H2➃-➁ Transformer 240V AC 1NO-1NC HW1L-M4F11M4➃-➁HW1L-A4F11M4➃-➁HW4L-M4F11M4➃-➁HW4L-A4F11M4➃-➁ 240V AC 2NO HW1L-M4F20M4➃-➁HW1L-A4F20M4➃-➁HW4L-M4F20M4➃-➁HW4L-A4F20M4➃-➁ 1NO HW2L-M1F10Q➃-➁-➂HW2L-A1F10Q➃-➁-➂Square Flush 1NC HW2L-M1F01Q➃-➁-➂HW2L-A1F01Q➃-➁-➂ Full Voltage –– 1NO-1NC HW2L-M1F11Q➃-➁-➂HW2L-A1F11Q➃-➁-➂ 2NO HW2L-M1F20Q➃-➁-➂HW2L-A1F20Q➃-➁-➂ 120V AC 1NO-1NC HW2L-M1F11H2➃-➁HW2L-A1F11H2➃-➁ 120V AC 2NO HW2L-M1F20H2➃-➁HW2L-A1F20H2➃-➁ Transformer –– 240V AC 1NO-1NC HW2L-M1F11M4➃-➁HW2L-A1F11M4➃-➁ 240V AC 2NO HW2L-M1F20M4➃-➁HW2L-A1F20M4➃-➁ ➁ Lens Color Code 1.In place of ➁ specify the Lens Color Code, in ➂ Full Voltage Codes place of ➂ specify the Full Voltage Code and in Color Code Voltage Code place of ➃ specify Lamp Type Code. Amber A 6V AC/DC 6V 2. For partial and sub-assembly part numbers, see Green G 12V AC/DC 12V pages A3-65 and A3-66. 3. For nameplates and accessories, see page A3-96. Red R 24V AC/DC 24V 4. For dimensions, see page A3-100. Blue S 120V AC (LED only) 120V ➃ Lamp Type Code White W 240VAC (LED only) 240V Lamp Code Yellow Y* Incandescent Blank *40mm mushroom lenses LED D not available in yellow A3-64 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Illuminated Pushbuttons (Partial-Assemblies) Contact Assembly + Lamp* + Operator/Lens = Complete Switch A3 *Lamp is included in contact assembly for transformer models only. Part Numbers: Operators/Lens Part Numbers: Full Voltage Contact Assemblies (order lamp separately) Type Plastic Bezel Metal Bezel Style Contacts Part Number Flush Momentary HW1L-M1-➁HW4L-M1-➁1NO HW-FL10Q0 2NO HW-FL20Q0 1NO/1NC HW-FL11Q0 1NC HW-FL01Q0 Maintained HW1L-A1-➁HW4L-A1-➁ 2NC HW-FL02Q0 Order lamp separately. Extended Momentary HW1L-M2-➁HW4L-M2-➁ Part Numbers: Transformer Contact Assemblies Maintained HW1L-A2-➁HW4L-A2-➁ (lamp included) Style Contacts Part Number Extended/Full shroud Momentary HW1L-MF2-➁HW4L-MF2-➁ 1NO HW-FL10H2-➁ 2NO HW-FL20H2-➁ 120V AC with LED 1NC HW-FL01H2-➁ Maintained HW1L-AF2-➁HW4L-AF2-➁1N0/1NC HW-FL11H2-➁ 1NO HW-FL10M4-➁ 2NO HW-FL20M4-➁Mushroom* 240V AC with LED Momentary HW1L-M4-➁* HW4L-M4-➁* 1NC HW-FL01M4-➁ 1N0/1NC HW-FL11M4-➁ 1NO HW-FL10T8-➁ 2NO HW-FL20T8-➁Maintained HW1L-A4-➁* HW4L-A4-➁* 480V AC with LED 1NC HW-FL01T8-➁ 1N0/1NC HW-FL11T8-➁ Square 1NO HW-FL10H2 Momentary HW2L-M1-➁– 120V AC with 2NO HW-FL20H2 Incandescent 1NC HW-FL01H2 1N0/1NC HW-FL11H2 Maintained HW2L-A1-➁ 1NO HW-FL10M4 240V AC with 2NO HW-FL20M4 Incandescent 1NC HW-FL01M4 1. In place of ➁, specify the Lens Color Code. 1N0/1NC HW-FL11M4 2. *Mushroom Lens not available in yellow. Part Numbers: Lamps ➁ Lens/LED Color Code Type Voltage Part Number Color Code 6V AC/DC LSTD-6➁ Amber A LED 12V AC/DC LSTD-1➁ Green G 24V AC/DC LSTD-2➁ Red R 120V AC LSTD-H2➁ Blue S 240V AC LSTD-M4➁ White W 6.3V AC/DC IS-6 Incandescent Yellow Y 12V AC/DC IS-12 24V AC/DC IS-24 30V AC/DC IS-30 1. In place of ➁, specify the LED Color Code from table below. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-65 ø22mm - HW Series Oiltight Switches & Pilot Devices Illuminated Pushbuttons (Sub-Assembled) Part Numbers: LED and Incandescent Illuminated Pushbuttons Transformer * + Contact Blocks + Lead Holder + Adaptor † + Lamp + Anti-Rotation Ring + Operator + Lens = Complete Part A3 1. * Transformer not needed with full voltage types. † 2. Adaptor includes safety lever lock. Part Numbers: Lenses Part Numbers: Operators Style Part Number Part Number Style Round Flush Plastic Metal Bezel Bezel HW1A-L1-➁Round Flush/Extended Momentary HW1L-M0 HW4L-M0 Round Extended HW1L-A0 HW4L-A0 Maintained HW1A-L2-➁Extended with Full Shroud HW1L-MF0 HW4L-MF0 Momentary Maintained HW1L-AF0 HW4L-AF0 Ş 40mm Mushroom Cap Ş 40mm Mushroom Head ALW4BLU-➁* Momentary HW1L-M0L HW4L-M0L Maintained HW1L-A0L HW4L-A0L Square Flush Square Flush Momentary HW2L-M0 HW2A-L1-➁ – Maintained HW2L-A0 I. n place of ➁, specify the Lens Color Code. 2. *not available in yellow. ➁ Lens/LED Color Code Color Code Amber A Green G Red R Blue S White W Yellow Y* *ALW4BLU not available in yellow. A3-66 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Illuminated Pushbuttons (Sub- Assembled) con’t Part Numbers: Anti-Rotation Ring Part Numbers: Contact Blocks Appearance Part Number Description Part Number 1NO 1NC Standard Fingersafe (IP20) A3 HW9Z-RL HW-F10 HW-F01 HW-F10R HW-F01R Use with notched panel cutout to prevent unit rotation (early make) (late break) Part Numbers: Lamps Spring-Up Terminal Contacts HW-G10 HW-G01 Type Voltage Part Number HW-G10R HW-G01R 6V AC/DC LSTD-6➁ LED (early make) (late break) 12V AC/DC LSTD-1➁ 24V AC/DC LSTD-2➁Exposed Screw Terminal Contacts 120V AC LSTD-H2➁ HW-C10 HW-C01 240V AC LSTD-M4➁ HW-C10R HW-C01R 6.3V AC/DC IS-6 (early make) (late break) Incandescent 12V AC/DC IS-12 24V AC/DC IS-24 Dummy Block 30V AC/DC IS-30 TW-DB 1. In place of ➁, specify the LED Color Code from table on previous page. 2. The LED contains a current-limiting resistor 1. All assembled part numbers in catalog include standard (HW- and reverse polarity protection diodes. F...) contacts. 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B- Part Numbers: Lamp Circuit Components M1F11-R becomes HW1B-M111-R). Style Description Terminals Part Number 3. Units with exposed screw terminals (HW-C...) must be ordered Lead Holder as sub-components. For use with HW-CBL on all illuminated pushbutton units. HW-LH3 One required for each deck Part Numbers: Contact Block Mounting Adaptor (pair) of contacts. (safety lever lock included) Style Part Number Dummy Block with Fingersafe HW-DA1FB Full Voltage Adaptor For use with odd Exposed HW-DA1B number of contacts. HW-CBL Spring Up HW-GA1 Full Voltage Adaptor Fingersafe TW-DA1FB 1. Used to mount contact blocks to operator For use with even (first pair only). Lamp holder is built-in. number of contacts. 2. IDEC strongly recommends using the safety Exposed TW-DA1B lever lock (included) to prevent heavy vibration or maintenance personnel from 120VAC TW-F126B unlocking contacts. Transformer Unit 240VAC Fingersafe TW-F246B 480VAC TW-F486B 120V HW-T126 240V Spring Up HW-T246 480V HW-L486 120V TW-T126B (6V secondary 240V Exposed TW-T246B voltage) 480V TW-T486B DC-DC Converter 110VDC HW-L16D HW-GA1 “Dummy Block with full voltage adaptor” does not require the use of HW-LH3. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-67 ø22mm - HW Series Oiltight Switches & Pilot Devices Selector Switches (Assembled) Part Numbers: 2–Position Selector Switches Spring Return from Operator Position Handle Maintained Right A3 LR L R L R Part Number Part Number Knob HW➄S-2TF10 HW➄S-21TF10 1O X 1NO Lever HW➄S-2LF10 HW➄S-21LF10 1NO- 1 O X Knob HW➄S-2TF11 HW➄S-21TF11 2 X O Lever 1NC HW➄S-2LF11 HW➄S-21LF11 1 O X Knob HW➄S-2TF20 HW➄S-21TF20 2NO 2 O X Lever HW➄S-2LF20 HW➄S-21LF20 Part Numbers: 3–Position Selector Switches ➄ Bezel Type Spring Return Spring Return Spring Return Operator Position Handle Maintained Type Code from Right from Left Two-Way Plastic 1 Metal 4 C C C C LC R L L L L R R R R Part Number Part Number Part Number Part Number 1NO- 1 O X X Knob HW➄S-3TF11 HW➄S-31TF11 HW➄S-32TF11 HW➄S-33TF11 2 O O X Lever 1NC HW➄S-3LF11 HW➄S-31LF11 HW➄S-32LF11 HW➄S-33LF11 1 X O O Knob HW➄S-3TF20 HW➄S-31TF20 HW➄S-32TF20 HW➄S-33TF20 2NO 2 O O X Lever HW➄S-3LF20 HW➄S-31LF20 HW➄S-32LF20 HW➄S-33LF20 1 X O O 2NO- 2 O O X Knob —— — HW➄S-3JTF21N1 1NC 3 O X O 1 X O O 2NO- 2 O O X Knob HW➄S-3TF22 HW➄S-31TF22 HW➄S-32TF22 HW➄S-33TF22 3 O X X 2NC 4 X X O Part Numbers: 4–Position Selector Switch Part Numbers: 5–Position Selector Switch Maintained Maintained Operator Position Handle Operator Position Handle Part Number Part Number 1234 2 12345 3 2 4 1 3 1 5 4 1 O X X X 1 X O O O O 1NO 2 O X O O Knob HW➄S-4TF13N6 2NO- HW➄S-5TF22N3 2 O X O O O Knob 3 O O X O Lever HW➄S-4LF13N6 3NC 3 O O O X O Lever HW➄S-5LF22N3 2NC 4 O O O X 4 O O O O X 1 X O O O 2NO- 2 O X O O Knob HW➄S-4TF22N3 3 O O X O Lever HW➄S-4LF22N3 2NC 4 O O O X 1. In place of ➄ enter 1 for plastic bezel or 4 for metal bezel. 2. Mounting refers to contact location on operator. See page A3-82. 3. For nameplates, see page A3-96. 4. Custom contact arrangements available. Contact IDEC for details. 5. Five position circuit cannot be made to make five independent con- tact closures, A3-68 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Contact Contact Contact Mounting Mounting Mounting Contact Mounting Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Selector Switches (Partial-Assemblies) Contact Assembly + Operator = Complete Part A3 Part Numbers: Operators No. of Positions Description Handle Plastic Bezel Metal Bezel Knob HW1S-2T HW4S-2T Maintained Lever HW1S-2L HW4S-2L 2 Knob HW1S-21T HW4S-21T Spring Return Knob Operator from Right (plastic bezel) (metal bezel) Lever HW1S-21L HW4S-21L Knob HW1S-3T* HW4S-3T* Maintained (standard cam) Lever HW1S-3L HW4S-3L Maintained (S cam) Knob HW1S-3ST* HW4S-3ST* Maintained (J cam) Knob HW1S-3JT* HW4S-3JT* Knob HW1S-31T HW4S-31T Spring Return Lever Operator 3 from Right (plastic bezel) Lever HW1S-31L HW4S-31L Knob HW1S-32T HW4S-32T Spring Return from Left Lever HW1S-32L HW4S-32L Knob HW1S-33T HW4S-33T 2-Way Spring Return Lever HW1S-33L HW4S-33L Knob HW1S-4T HW4S-4T 4 Maintained Lever HW1S-4L HW4S-4L Lever HW1S-5T HW4S-5T 5 Maintained Lever HW1S-5L HW4S-5L 1. Knob operator includes knob. 2. * Three position operator is available with three different cams. 3. Operator cams are color coded (white=standard cam, red=S cam, black =J cam). 4. For details of determining which cam to use, see page A3-79. Part Numbers: Contact Assemblies Style Contacts Part Number Standard Fingersafe Contacts 1NO HW-CBF10 1NC HW-CBF01 1NO/1NC HW-CBF11 2NO HW-CBF20 2NC HW-CBF02 2NO/2NC HW-CBF22 Spring Up Terminal Contacts 1NO HW-CB10 1NC HW-CB01 1NO/1NC HW-CB11 2NO HW-CB20 2NC HW-CB02 2NO/2NC HW-CB22 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-69 ø22mm - HW Series Oiltight Switches & Pilot Devices Selector Switches (Sub-Assembled) Adaptor and Contact Blocks + + Anti-Rotation Ring + Operator = Complete Part Safety Lever Lock A3 Part Numbers: Operators Part Numbers: Contact Block # of Plastic Metal Mounting Adaptor (safety lever Style Description Handle Positions Bezel Bezel lock included) Knob HW1S-2T HW4S-2T Part Appearance Maintained Number Lever HW1S-2 HW4S-2 2 Knob HW1S-21T HW4S-21T Spring Return from Right Lever HW1S-21 HW4S-21 HW-CB2C Knob HW1S-3T* HW4S-3T* Knob Operator Maintained (standard cam) Lever HW1S-3* HW4S-3* Maintained (S cam) Knob HW1S-3ST* HW4S-3ST* 1. Used to mount contact blocks to Maintained (J cam) Knob HW1S-3JT* HW4S-3JT* operator (first pair only). Spring Return Knob HW1S-31T HW4S-31T 2. IDEC strongly recommends using from Right 3 the safety lever lock (included) to Lever HW1S-31 HW4S-31 (standard cam) prevent heavy vibration or main- Lever Operator Spring Return Knob HW1S-32T HW4S-32T tenance personnel from unlock- from Left Lever HW1S-32 HW4S-32 ing contacts. (standard cam) 2-Way Spring Knob HW1S-33T HW4S-33T Part Numbers: Contact Blocks Return Description Part Number Lever HW1S-33 HW4S-33 (standard cam) Knob HW1S-4T HW4S-4T 4 Maintained Lever HW1S-4 HW4S-4 1NO 1NC Knob HW1S-5T HW4S-5T 5 Maintained Lever HW1S-5 HW4S-5 Standard HW-F10 HW-F01 1. Knob operator comes with handle. Fingersafe HW-F10R HW-F01R 2. * Three position operator is available with three different cams. (IP20) (early make) (late break) 3. Operator cams are color coded (white=standard cam, red=S cam, black =J cam). Spring-Up HW-G10 HW-G01 4. For details of determining which cam to use, see page A3-79. Terminal HW-G10R HW-G01R 5. To order colored handle type, knob/lever and inserts must be ordered separately, Contacts (early make) (late break) along with lever operator. See part numbers below. Exposed HW-C10 HW-C01 Screw Termi- HW-C10R HW-C01R Part Numbers: Levers and Inserts nal Contacts (early make) (late break) Style Part Number Dummy Block TW-DB Knob ASWHHY-①① Handle/Insert Color Code 1. All assembled part numbers in catalog include standard (HW-F...) contacts. Color Code Color Code 2. Assembled units with spring-up terminals Lever Black* B Red R (HW-G...) can be ordered by removing an ASWHHL-① Blue S Yellow Y “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B- † Green G W White Lever M111-R). Color * Lever color inserts not available in black. 3. Units with exposed screw terminals (HW- TW-HC1-①† Knob and lever not available in white. Insert C...) must be ordered as sub-components. Part Numbers: Anti-Rotation Ring Appearance Part Number 1. Use with notched panel cutout to prevent unit rotation. HW9Z-RL 2. Not required when using HW series nameplates. See page A3-96. A3-70 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Key Switches (Assembled) A3 Part Numbers: 2–Position Key Switches Key Removable Option Codes Part Number Code Description Operator Position Maintained Spring Return from Right A Key retained in NO position (removable in all positions) B Key retained in right position only LR C Key retained in left position only L R L R D Key retained in left and right (3 position only) E Key retained in center only (3 position only) 1NO1O X HW➄K-2AF10 HW➄K-21BF10 G Key retained right and center (3 position only) 1O X 1NO- H Key retained left and center (3 position only) HW➄K-2AF11 HW➄K-21BF11 1NC 2X O For more information on these options, contact 1O X your IDEC representative. 2NO HW➄K-2AF20 HW➄K-21BF20 2O X Part Numbers: 3–Position Key Switches Part Number Operator Position Spring Return Spring Return Spring Return ➄ Bezel Type Maintained from Right from Left from Left & Right Type Code Plastic 1 LC R C C C C Metal 4 L L L L R R R R 10 X X 1NO- HW➄K-3AF11 HW➄K-31BF11 HW➄K-32CF11 HW➄K-33DF11 1NC 20 0 X 1X O O 2NO HW➄K-3AF20 HW➄K-31BF20 HW➄K-32CF20 HW➄K-33DF20 2O O X 1X O O 2O O X 2NO- HW➄K-3AF22 HW➄K-31BF22 HW➄K-32CF22 HW➄K-33DF22 2NC 3O X X 4X X O 1. In place of ➄ enter 1 for plastic bezel or 4 for metal bezel (see table at right). 2. Key is removable in all maintained positions. Other key removable options available. 3. Two keys are supplied with all switches. 4. All standard operators are keyed alike (contact IDEC for special keys). 5. For nameplates, see page A3-96. 6. Custom contact arrangements available, contact IDEC for details. 7. Mounting refers to contact location on operator. See page A3-82. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-71 Contact Contact Mounting Mounting ø22mm - HW Series Oiltight Switches & Pilot Devices Key Switches (Partial-Assemblies) Contact Assembly + Operator = Complete Part A3 Part Numbers: Operators # of Positions Description Plastic Bezel Metal Bezel Maintained HW1K-2A HW4K-2A Maintained, key 2 HW1K-2B HW4K-2B remove left only Spring from Right HW1K-21B HW4K-21B Maintained, Stan- HW1K-3A HW4K-3A dard Cam Maintained, Cam S HW1K-3SA HW4K-3SA Maintained, Cam J HW1K-3JA HW4K-3JA Spring Return from 3 HW1K-31B HW4K-31B Right Spring Return from HW1K-32C HW4K-32C Left Two-Way Spring HW1K-33D HW4K-33D Return 1. Operator includes two keys. 2. All standard operators are keyed alike (contact IDEC for special keys). 3. Other key removable options available. See “Other Key Removable Option Codes” on next page. Part Numbers: Contact Assemblies Key Removable Option Codes Style Contacts Part Number Code Description Key retained in NO position (removable in all Standard Fingersafe Contacts 1NO HW-CBF10 A positions) 1NC HW-CBF01 1NO/1NC HW-CBF11 B Key retained in right position only 2NO HW-CBF20 2NC HW-CBF02 C Key retained in left position only 2NO/2NC HW-CBF22 D Key retained in left and right (3 position only) Spring Up Terminal Contacts E Key retained in center only (3 position only) 1NO HW-CB10 1NC HW-CB01 G Key retained right and center (3 position only) 1NO/1NC HW-CB11 2NO HW-CB20 H Key retained left and center (3 position only) 2NC HW-CB02 2NO/2NC HW-CB22 1. For more information on these op- tions, contact your IDEC representative. 2. Key retained in all spring-return positions. A3-72 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Key Switches (Sub-Assembled) Contact Blocks + Adaptor & Safety Lever Lock + Anti-Rotation Ring + Operator = Complete Part A3 Part Numbers: Operators Part Numbers: Contact Blocks # of Plastic Metal Description Part Number Description Positions Bezel Bezel 1NO 1NC Maintained HW1K-2A HW4K-2A Standard Fingersafe (IP20) 2 Maintained, key remove left only HW1K-2B HW4K-2B HW-F10 HW-F01 Spring from Right HW1K-21B HW4K-21B HW-F10R HW-F01R Maintained, Standard Cam HW1K-3A HW4K-3A (early make) (late break) Maintained, Cam S HW1K-3SA HW4K-3SA Maintained, Cam J HW1K-3JA HW4K-3JA 3 Spring-Up Terminal Contacts Spring Return from Right HW1K-31B HW4K-31B HW-G10 HW-G01 Spring Return from Left HW1K-32C HW4K-32C HW-G10R HW-G01R Two-Way Spring Return HW1K-33D HW4K-33D (early make) (late break) 1. Operator includes two keys. 2. All standard operators are keyed alike Exposed Screw Terminal Contacts (contact IDEC for special keys). HW-C10 HW-C01 3. Other key removable options available. See table below. HW-C10R HW-C01R (early make) (late break) Part Numbers: Contact Block Mounting Adaptor (safety lever lock included) Dummy Block Style Part Number TW-DB HW-CB2C 1. All assembled part numbers in catalog include stan- dard (HW-F...) contacts. 2. Assembled units with spring-up terminals (HW- 1. Used to mount contact blocks to operator G...) can be ordered by removing an “F” from the (first pair only). part number (Ex. HW1B-M1F11-R becomes 2. IDEC strongly recommends using the safety lever HW1B-M111-R). lock (included) to prevent heavy vibration or mainte- 3. Units with exposed screw terminals (HW-C...) must nance personnel from unlocking contacts. be ordered as sub-components. Key Removable Option Codes Part Numbers: Anti-Rotation Ring Code Description Appearance Part Number A Key retained in NO position (removable in all positions) B Key retained in right position only HW9Z-RL C Key retained in left position only D Key retained in left and right (3 position only) 1. Use with notched panel cutout to prevent unit E Key retained in center only (3 position only) rotation (not included with assembled units). G Key retained right and center (3 position only) 2. Not required when using HW series nameplates See page A3-96. H Key retained left and center (3 position only) For more information on these options, contact your IDEC representative. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-73 ø22mm - HW Series Oiltight Switches & Pilot Devices Illuminated Selector Switches (Assembled) A3 Part Numbers: 2–Position LED/Incandescent Selector Switches Plastic Bezel Operator Position Type Part Number Part Number Maintained Spring Return From Right LR L L R R Full Voltage HW➄F-2F11Q➃-➁-➂HW➄F-21F11Q➃-➁-➂ 1NO- 1 O X HW➄F-2F11H2➃-➁HW➄F-21F11H2➃-➁120V 2 X O 1NC Transformer 240V HW➄F-2F11M4➃-➁HW➄F-21F11M4➃-➁ 480V HW➄F-2F11T8➃-➁HW➄F-21F11T8➃-➁ Full Voltage HW➄F-2F20Q➃-➁-➂HW➄F-21F20Q➃-➁-➂ 1 O X HW➄F-2F20H2➃-➁HW➄F-21F20H2➃-➁2NO 120V 2 O X Transformer 240V HW➄F-2F20M4➃-➁HW➄F-21F20M4➃-➁ 480V HW➄F-2F20T8➃-➁HW➄F-21F20T8➃-➁ Full Voltage HW➄F-2F22Q➃-➁-➂HW➄F-21F22Q➃-➁-➂ 1 O X 2NO- 2 X O HW➄F-2F22H2➃-➁HW➄F-21F22H2➃-➁120V 3 O X 2NC Transformer 240V HW➄F-2F22M4➃-➁HW➄F-21F22M4➃-➁ 4 X O 480V HW➄F-2F22T8➃-➁HW➄F-21F22T8➃-➁ 1. In place of ➁ specify the Lens/LED color code. 2. In place of ➂ specify the Full Voltage code. 3. In place of ➃ specify Lamp Type code. 4. In place of ➄ enter 1 for plastic bezel or 4 for metal bezel (see table below). 5. For nameplates, see page A3-96. 6. For partial and sub-assembly part numbers, see pages A3-76 and A3-77. 7. Mounting refers to contact location on operator. See page A3-82. ➄ Bezel Type ➁ Lens/LED Color Code ➂ Full Voltage Code➃ Lamp Type Code Type Code Color Code Voltage Code Lamp Code Amber A 6V AC/DC 6V Incandescent Blank Plastic 1 Green G 12V AC/DC 12V LED D Metal 4 Red R 24V AC/DC 24V Blue S 120V AC 120 V (LED only) White W 240V AC 240 V Yellow Y (LED only) A3-74 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Contact Mounting Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Illuminated Selector Switches (Assembled) con’t Part Numbers: 3–Position LED/Incandescent Selector Switches Operator Position Type Part Number Part Number Part Number Part Number Spring Return Spring Return Spring Return From Left Two-Way From Right Maintained LC R C C C C A3 L L L L R R R R Full Voltage HW➄F-3F11Q➃-➁-➂HW➄F-31F11Q➃-➁-➂HW➄F-32F11Q➃-➁-➂HW➄F-33F11Q➃-➁-➂ 1NO- 1 O X X 120V HW➄F-3F11H2➃-➁HW➄F-31F11H2➃-➁HW➄F-32F11H2➃-➁HW➄F-33F11H2➃-➁ 2 O O X 1NC Transformer 240V HW➄F-3F11M4➃-➁HW➄F-31F11M4➃-➁HW➄F-32F11M4➃-➁HW➄F-33F11M4➃-➁ 480V HW➄F-3F11T8➃-➁HW➄F-31F11T8➃-➁HW➄F-32F11T8➃-➁HW➄F-33F11T8➃-➁ Full Voltage HW➄F-3F20Q➃-➁-➂HW➄F-31F20Q➃-➁-➂HW➄F-32F20Q➃-➁-➂HW➄F-33F20Q➃-➁-➂ 1 X O O 120V HW➄F-3F20H2➃-➁HW➄F-31F20H2➃-➁HW➄F-32F20H2➃-➁HW➄F-33F20H2➃-➁2NO 2 O O X Transformer 240V HW➄F-3F20M4➃-➁HW➄F-31F20M4➃-➁HW➄F-32F20M4➃-➁HW➄F-33F20M4➃-➁ 480V HW➄F-3F20T8➃-➁HW➄F-31F20T8➃-➁HW➄F-32F20T8➃-➁HW➄F-33F20T8➃-➁ Full Voltage HW➄F-3F02Q➃-➁-➂HW➄F-31F02Q➃-➁-➂HW➄F-32F02Q➃-➁-➂HW➄F-33F02Q➃-➁-➂ 1 O X X 120V HW➄F-3F02H2➃-➁HW➄F-31F02H2➃-➁HW➄F-32F02H2➃-➁HW➄F-33F02H2➃-➁2NC 2 X X O Transformer 240V HW➄F-3F02M4➃-➁HW➄F-31F02M4➃-➁HW➄F-32F02M4➃-➁HW➄F-33F02M4➃-➁ 480V HW➄F-3F02T8➃-➁HW➄F-31F02T8➃-➁HW➄F-32F02T8➃-➁HW➄F-33F02T8➃-➁ Full Voltage HW➄F-3F22Q➃-➁-➂HW➄F-31F22Q➃-➁-➂HW➄F-32F22Q➃-➁-➂HW➄F-33F22Q➃-➁-➂1 X O O 2NO- 2 O O X 120V HW➄F-3F22H2➃-➁HW➄F-31F22H2➃-➁HW➄F-32F22H2➃-➁HW➄F-33F22H2➃-➁ 3 O X X 2NC Transformer 240V HW➄F-3F22M4➃-➁HW➄F-31F22M4➃-➁HW➄F-32F22M4➃-➁HW➄F-33F22M4➃-➁ 4 X X O 480V HW➄F-3F22T8➃-➁HW➄F-31F22T8➃-➁HW➄F-32F22T8➃-➁HW➄F-33F22T8➃-➁ Full Voltage HW➄F-3F40Q➃-➁-➂HW➄F-31F40Q➃-➁-➂HW➄F-32F40Q➃-➁-➂HW➄F-33F40Q➃-➁-➂1 X O O 2 O O X 120V HW➄F-3F40H2➃-➁HW➄F-31F40H2➃-➁HW➄F-32F40H2➃-➁HW➄F-33F40H2➃-➁4NO 3 X O O Transformer 240V HW➄F-3F40M4➃-➁HW➄F-31F40M4➃-➁HW➄F-32F40M4➃-➁HW➄F-33F40M4➃-➁ 4 O O X 480V HW➄F-3F40T8➃-➁HW➄F-31F40T8➃-➁HW➄F-32F40T8➃-➁HW➄F-33F40T8➃-➁ Full Voltage HW➄F-3F04Q➃-➁-➂HW➄F-31F04Q➃-➁-➂HW➄F-32F04Q➃-➁-➂HW➄F-33F04Q➃-➁-➂1 O X X 2 X X O 120V HW➄F-3F04H2➃-➁HW➄F-31F04H2➃-➁HW➄F-32F04H2➃-➁HW➄F-33F04H2➃-➁4NC 3 O X X Transformer 240V HW➄F-3F04M4➃-➁HW➄F-31F04M4➃-➁HW➄F-32F04M4➃-➁HW➄F-33F04M4➃-➁ 4 X X O 480V HW➄F-3F04T8➃-➁HW➄F-31F04T8➃-➁HW➄F-32F04T8➃-➁HW➄F-33F04T8➃-➁ 1. In place of ➁ specify the Lens/LED color code. 2. In place of ➂ specify the Full Voltage code. 3. In place of ➃ specify Lamp Type code. 4. In place of ➄ enter 1 for plastic bezel or 4 for metal bezel (see table below). 5. For nameplates, see page A3-96. 6. For partial and sub-assembly part numbers, see pages A3-76 and A3-77. 7. Mounting refers to contact location on operator. See page A3-82. ➂ Full Voltage Code➃ Lamp Type Code ➄ Bezel Type ➁ Lens/LED Color Code Voltage Code Lamp Code Type Code Color Code Plastic 1 Amber A 6V AC/DC 6V Incandescent Blank Metal 4 Green G 12V AC/DC 12V LED D Red R 24V AC/DC 24V Blue S 120V AC 120 V (LED only) White W 240V AC 240 V Yellow Y (LED only) www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-75 Contact Mounting ø22mm - HW Series Oiltight Switches & Pilot Devices Illuminated Selector Switches (Partial-Assemblies) Contact Assembly + Lamp + Operator/Lens = Complete Part A3 Full Voltage Models Part Numbers: Operators/Lens Part Numbers: Lamps Type Plastic Metal Type Voltage Part Number Maintained HW1F-2➁HW4F-2➁ 6V AC/DC LSTD-6➁ Spring from Right HW1F-21➁HW4F-21➁LED 12V AC/DC LSTD-1➁ Maintained HW1F-3➁HW4F-3➁ 24V AC/DC LSTD-2➁ Spring from Right HW1F-31➁HW4F-31➁ 120V AC LSTD-H2➁ Spring from Left HW1F-32➁HW4F-32➁ 240V AC LSTD-M4➁Spring from Both HW1F-33➁HW4F-33➁ Incandescent 6.3V AC/DC IS-6 In place of ➁, specify the Lens Color Code from table below. 12V AC/DC IS-12 Part Numbers: Contact Assemblies (order lamp separately) 24V AC/DC IS-24 Style Contacts Part Number 1. In place of ➁, specify the LED Color Code from 1NO HW-FL10Q0 2NO HW-FL20Q0 table below. 1NO/1NC HW-FL11Q0 2. The LED contains a current-limiting resistor 1NC HW-FL01Q0 and reverse polarity protection diodes. 2NC HW-FL02Q0 Order lamp separately from table on right. Transformer Models Part Numbers: Contact Assemblies (lamp included) Part Numbers: Operators/Lens Type Plastic Metal Style Contacts Part Number Maintained HW1F-2➁HW4F-2➁ 1NO HW-FL10H2-➁ 2NO HW-FL20H2-➁Spring from Right HW1F-21➁HW4F-21➁ 120V AC with LED 1NC HW-FL01H2-➁ Maintained HW1F-3➁HW4F-3➁1NO/1NC HW-FL11H2-➁ 1NO HW-FL10M4-➁Spring from Right HW1F-31➁HW4F-31➁ 2NO HW-FL20M4-➁ 240V AC with LED Spring from Left HW1F-32➁HW4F-32➁1NC HW-FL01M4-➁ 1NO/1NC HW-FL11M4-➁ Spring from Both HW1F-33➁HW4F-33➁ 1NO HW-FL10T8-➁ 2NO HW-FL20T8-➁ In place of ➁, specify the Lens Color 480V AC with LED 1NC HW-FL01T8-➁Code from table below. 1NO/1NC HW-FL11T8-➁ 1NO HW-FL10H2 ➁ Lens/LED Color Code 120V AC with 2NO HW-FL20H2 Incandescent 1NC HW-FL01H2 Color Code 1NO/1NC HW-FL11H2 Amber A 1NO HW-FL10M4 240V AC with 2NO HW-FL20M4 Green G Incandescent 1NC HW-FL01M4 Red R 1NO/1NC HW-FL11M4 Blue S 6V LED/Lamp included with transformer sub-assembly. White W Yellow Y A3-76 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices 3 pos. 2 pos. 3 pos. 2 pos. Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Illuminated Selector Switches (Sub-Assembled) Illuminated Transformer * + Contact Blocks + Lead Holder + Adaptor + Lamp + Anti-Rotation + Operator + = Complete Part Knob A3 * not applicable for full voltage units Part Numbers: Operators Part Numbers: Contact Blocks # of Plastic Metal Description Part Number Appearance Description Positions Bezel Bezel 1NO 1NC Maintained HW1F-2 HW4F-2 Standard Fingersafe (IP20) 2 Spring return HW1F-21 HW4F-21 from right HW-F10 HW-F01 Maintained HW1F-3 HW4F-3 HW-F10R HW-F01R (early make) (late break) Spring return HW1F-31 HW4F-31 from right 3 Spring return HW1F-32 HW4F-32 Spring-Up Terminal Contacts from left HW-G10 HW-G01 Two-way HW1F-33 HW4F-33 spring return HW-G10R HW-G01R (early make) (late break) Illuminated knobs must be ordered separately. Exposed Screw Terminal Contacts Part Numbers: Illuminated Knob HW-C10 HW-C01 Appearance Description Part Number HW-C10R HW-C01R Amber HW9Z-FDY-A (early make) (late break) Green HW9Z-FDY-G Red HW9Z-FDY-R Dummy Block Blue HW9Z-FDY-S White HW9Z-FDY-W TW-DB Yellow HW9Z-FDY-Y Part Numbers: Contact Block Mounting Adaptor (safety lever lock included) 1. All assembled part numbers in catalog include Style Part Number standard (HW-F...) contacts. 2. Assembled units with spring-up terminals (HW- G...) can be ordered by removing an “F” from the part number HW-CBL (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 1. Used to mount contact blocks to operator (first pair only). Lamp holder is built-in. 2. IDEC strongly recommends using the safety le- ver lock (included) to prevent heavy vibration or maintenance personnel from unlocking contacts. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-77 ø22mm - HW Series Oiltight Switches & Pilot Devices Illuminated Selector Switches (Sub- Assembled) con’t Part Numbers: Lamps Part Numbers: Transformer Unit Type Voltage Part Number Style Voltage Part Number 6V AC/DC LSTD-6➁120V AC TW-F126B A3 240V AC TW-F246B Fingersafe LED 480V AC TW-F486B 12V AC/DC LSTD-1➁ Spring Up 24V AC/DC LSTD-2➁ 120V AC HW-T126 120V AC LSTD-H2➁ 240V AC HW-T246 480V AC HW-L486 240V AC LSTD-M4➁ Incandescent 6.3V AC/DC IS-6 (6V secondary voltage) DC-DC Converter 110VDC HW-L16D 12V AC/DC IS-12 1. DC-DC convertor features spring-up terminals. 24V AC/DC IS-24 2. Applicable voltage range 90-140V DC. 1. In place of ➁, specify the LED Color Code from table at right. 2. The LED contains a current-limiting resis- ➁ LED Color Code tor and reverse polarity protection diodes. Color Code Amber A Part Numbers: Lamp Circuit Components Green G Style Description Terminals Part Number Red R Lead Holder For use with HW-CBL on all S Blue illuminated pushbutton units. HW-LH3 One required for each deck White W (pair) of contacts. Y Yellow Dummy Block with Fingersafe HW-DA1FB Full Voltage Adaptor Part Numbers: Anti-Rotation Ring For use with odd Exposed HW-DA1B number of contacts. Appearance Part Number Spring Up HW-GA1 HW9Z-RL Full Voltage Adaptor Fingersafe TW-DA1FB For use with even number of contacts. 1. Use with notched panel cutout to prevent unit rotation. Exposed TW-DA1B 2. Not required when using HW series nameplates See page A3-96. HW-GA1 “Dummy Block with full voltage adaptor” does not require the use of HW-LH3. A3-78 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Custom Selector Switch Building Guide To build a custom selector switch, follow these steps. Step1: How many positions of the switch are needed? # of positions A3 (2, 3, 4, 5) Step 2: How many contacts should there be? # of isolated contacts (maximum 6) Step 3: Fill in the Truth Table (X = closed, O = open) Knob Position 12345 1 C o 2 n 3 t a 4 c 5 t s 6 Step 4: If building a 2, 4, or 5 position selector, skip this step. (2, 4, 5 position selectors have only one cam) If building a 3 position selector, determine appropriate cam as follows: Look at Row 1 from above table and locate an identical row in the operator truth tables (See next page). Repeat for all rows. Find one operator that contains all rows from above table. Record the operator cam version. Operator CAM Version (blank, S, J for 3 position) Step 5: Build by placing appropriate contact in appropriate mounting position for each desired row on operator cam truth table. “L” and “R” refer to mounting on left or right side of operator as viewed from the front of the panel. Caution: Before putting any custom selector switch into use, it should be tested using an ohmmeter. For Operator Truth Tables, see next page. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-79 ø22mm - HW Series Oiltight Switches & Pilot Devices Operator Truth Tables Use the following tables to build custom selector switches. 2 Position Selector Switches 1. Mounting position indicates which side of operator each Operator contact should be mounted (as viewed from the front of the A3 Mounting Position Contact panel). Position Left Right 2. * for key removable code (see page A3-73). LO X HW-F10 (NO) RO X LX O HW-F01 (NC) HW1S-2T RX O HW1K-2* L0 X HW1F-2 HW-F10R NO-(EM) RO X LX O HW-F01R NC-(LB) RX O 3 Position Selector Switches 1. HW1S-3T is identified by white plungers on the operator. Operator Position Mounting Contact 2. Mounting position indicates which side of operator each Position Left Center Right contact should be mounted (as viewed from the front of the LX O O panel). HW-F10 (NO) 3. * for key removable code (see page A3-73). RO O X LO X X HW-F01 (NC) HW1S-3T RX X O HW1K-3* LX O O HW1F-3 HW-F10R NO-(EM) RO O X LO X X HW-F01R NC-(LB) RX X O 1. HW1S-3ST is identified by red plungers on the operator. Operator Position Mounting Contact 2. Mounting position indicates which side of operator each Position Left Center Right contact should be mounted (as viewed from the front of the panel). LX O O HW-F10 (NO) 3. * for key removable code (see page A3-73). RO O X LO O X HW-F01 (NC) HW1S-3ST RX O O HW1K-3S* LX X O HW-F10R NO-(EM) RO X X LO X X HW-F01R NC-(LB) RX X O 1. HW1S-3JT is identified by black plungers on the operator. Operator Position Mounting 2. Mounting position indicates which side of operator each Contact Position Left Center Right contact should be mounted (as viewed from the front of the panel). LX O O HW-F10 (NO) 3. * for key removable code (see page A3-73). RO O X L OXO HW-F01 (NC) HW1S-3JT R OXO HW1K-3J* L XOX HW-F10R NO-(EM) R XOX LO X X HW-F01R NC-(LB) RX X O A3-80 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Operator Truth Tables con’t 4 Position Selector Switches Operator Position Mounting Contact Position A3 1234 LX OOO HW-F10 (NO) R OOO X LO OXO HW-F01 (NC) R OXO O HW1S-4T LX XOX HW-F10R NO-(EM) R XOX X LO XXX HW-F01R NC-(LB) R XXX O 5 Position Selector Switches Mounting position indicates which side of operator each contact Operator Position Mounting should be mounted (as viewed from Contact Position 12345 the front of the panel). LX OOOO HW-F10 (NO) R OOOO X L OO OXO HW-F01 (NC) R OX OOO HW1S-5T L XX XOX HW-F10R NO-(EM) R XO XXX LO XXXX HW-F01R NC-(LB) R XXXX O www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-81 ø22mm - HW Series Oiltight Switches & Pilot Devices Custom Selector Switch Building Examples Example 1: 3 Position, Maintained Selector Switch with 3 Contacts Determine which operator is capable of producing all the desired contact actions. A3 Knob Position Operator Left Center Right HW1S-3T HW1S-3ST HW1S-3JT Possible with Possible with Possible with OO X Contact 1 HW-F10 mounted on right HW-F10 mounted on right HW-F10 mounted on right Possible with 0X O Not possible Not possible Contact 2 HW-F01 mounted on left or right Possible with Possible with Possible with XO O Contact 3 HW-F10 mounted on left HW-F10 mounted on left HW-F10 mounted on left The only operator in this example that will produce all the desired contact actions is HW1S-3JT. Assemble as follows: Right TW-DB (dummy block) Left HW-F10 HW-F01 HW-F10 HW1S-3JT Example 2: 3 Position, Maintained Selector Switch with 2 Contacts Determine which operator is capable of producing all the desired contact actions. Knob Position Operator Left Center Right HW1S-3T HW1S-3ST HW1S-3JT Possible with Possible with Possible with OO X Contact 1 HW-F10 mounted on right HW-F10 mounted on right HW-F10 mounted on right Possible with Possible with 0X X HW-F10R mounted on right or Not possible Contact 2 HW-F01 mounted on left HW-F01R mounted on left This arrangement is possible with either the HW1S-3T or HW1S-3ST operator. It is preferred to use the HW1S-3T as this requires only the standard contacts (HW- F10 and HW-F01 and not the early make (HW-F10R) or late break (HW-F01R) contacts. Assemble as follows: Right Left HW-F10 HW-F01 HW1S-3T A3-82 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Custom Selector Switch Building Examples con’t Example 3: 4 Position Selector Switch with 4 Contacts Determine where the contact will be mounted. Knob Position Operator A3 1 2 3 4 HW1S-4T Contact 1 OXO OHW-F01 mounted on right Contact 2 0 OXO HW-F01 mounted on left Contact 3 OOO XHW-F10 mounted on right Contact 4 O XXX HW-F01R mounted on left Assemble as follows: Right HW-F01 Left HW-F10 HW-F01 HW-F01R HW1S-4T Example 4: 5 Position Selector Switch with 4 Contacts Determine where the contact will be mounted. Knob Position Operator 1 2 3 4 5 HW1S-5T Contact 1 OX OOO HW-F01 mounted on right Contact 2 OO OXO HW-F01 mounted on left Contact 3 OOOO X HW-F10 mounted on right Contact 4 XO XXX HW-F10R mounted on right Assembled as follows: HW-F01 Right Left HW-F10 HW-F10R TW-DB (dummy block) TW-DB (dummy block) HW-F01 HW1S-5T www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-83 ø22mm - HW Series Oiltight Switches & Pilot Devices Dual Pushbutton Switches Two pushbuttons and a pilot light are integrated into one space- saving ş22 mm control unit. • Momentary and interlock types are available for pushbuttons. Interlock type prevents both buttons from being pressed at the same time. A3 • Pilot lights are available in full voltage and transformer types illuminated with LED or incandescent lamps. • IP40 protection, IP65 when using silicon cover. • UL Listed, CSA approved, and EN compliant Applications: • Ideal for use as power switches and start/stop switches (available with I/ON and O/OFF markings on the buttons and a pilot light in the center). • Interlock type prevents two pushbuttons from being pressed at the same time. Dual Pushbutton Switches (Assembled) Part Numbers: Contact Arrangement Operation ➃ Button Button Style Part Number ➄ Legend Code Top Bottom Type Color Code Button Button 1NO 1NC HW7D-B11F1001-➃➄ 1NO 1NO HW7D-B11F1010-➃➄ Flush (top) 1NO-1NC 1NO-1NC HW7D-B11F1111-➃➄ Flush (bottom) 2NO 2NC HW7D-B11F2002-➃➄ 2NO 2NO HW7D-B11F2020-➃➄ Momentary 1NO 1NC HW7D-B12F1001-➃➄ 1NO 1NO HW7D-B12F1010-➃➄ Flush (top) 1NO-1NC 1NO-1NC HW7D-B12F1111-➃➄ Extended (bottom) GR: 2NO 2NC HW7D-B12F2002-➃➄ Green (top) Blank:Without legend Red (bottom) 2NO 2NO HW7D-B12F2020-➃➄ 1:I/ON (top) 1NO 1NC HW7D-B21F1001-➃➄WB: O/OFF (bottom) White (top) 1NO 1NO HW7D-B21F1010-➃➄ Black (bottom) Flush (top) 1NO-1NC 1NO-1NC HW7D-B21F1111-➃➄ Flush (bottom) 2NO 2NC HW7D-B21F2002-➃➄ 2NO 2NO HW7D-B21F2020-➃➄ Interlock* 1NO 1NC HW7D-B22F1001-➃➄ 1NO 1NO HW7D-B22F1010-➃➄ Flush (top) 1NO-1NC 1NO-1NC HW7D-B22F1111-➃➄ Extended (bottom) 2NO 2NC HW7D-B22F2002-➃➄ 2NO 2NO HW7D-B22F2020-➃➄ 1. *Interlock type prevents both top and bottom buttons from being pressed simultaneously. 2. Clear silicon rubber cover part number HW9Z-D7D. A3-84 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Part Numbers, con’t Part Numbers: With Center Pilot Light ➁Pilot Light Illumination Type Pilot Light Top Bottom Operation Type Button Style Part Number and Voltage Code Type Button Button Full Voltage 1NO 1NC HW7D-L11F1001➁➂-➃➄ Voltage Code 1NO 1NO HW7D-L11F1010➁➂-➃➄A3 6V AC/DC, LED Q2 Full Voltage 1NO-1NC 1NO-1NC HW7D-L11F1111➁➂-➃➄ 12V AC/DC, LED Q3 2NO 2NC HW7D-L11F2002➁➂-➃➄ 24V AC/DC, LED Q4 Flush (Top) 2NO 2NO HW7D-L11F2020➁➂-➃➄ Flush 120V AC, LED Q8 (Bottom) 1NO 1NC HW7D-L11F1001➁➂-➃➄ 6V AC/DC, Incandescent Q5* 1NO 1NO HW7D-L11F1010➁➂➃➄ 12V AC/DC, Incandescent Q6* Transformer 1NO-1NC 1NO-1NC HW7D-L11F1111➁➂-➃➄ 24V AC/DC, Incandescent Q7* 2NO 2NC HW7D-L11F2002➁➂-➃➄ Step-Down Transformer 2NO 2NO HW7D-L11F2020➁➂-➃➄ (6V Secondary Lamp Voltage) 1NO 1NC HW7D-L12F1001➁➂-➃➄ Voltage Code 1NO 1NO HW7D-L12F1010➁➂-➃➄ 120V AC, LED H22 Full Voltage 1NO-1NC 1NO-1NC HW7D-L12F1111➁➂-➃➄ 240V AC, LED M42 2NO 2NC HW7D-L12F2002➁➂-➃➄ 480V AC, LED T82 Flush (Top) 2NO 2NO HW7D-L12F2020➁➂-➃➄ 120V AC, Incandescent H25* Extended (Bottom) 1NO 1NC HW7D-L12F1001➁➂-➃➄ 240V AC, Incandescent M45* 1NO 1NO HW7D-L12F1010➁➂-➃➄ 480V AC, Incandescent T85* Transformer 1NO-1NC 1NO-1NC HW7D-L12F1111➁➂-➃➄ * Only available for White Lens Flush (top) 2NO 2NC HW7D-L12F2002➁➂-➃➄ Pilot Lamp. Flush (bottom) 2NO 2NO HW7D-L12F2020➁➂-➃➄ 1NO 1NC HW7D-L21F1001➁➂-➃➄ ➂Pilot Lamp Color Code 1NO 1NO HW7D-L21F1010➁➂-➃➄ Color Code Full Voltage 1NO-1NC 1NO-1NC HW7D-L21F1111➁➂-➃➄ Amber A* 2NO 2NC HW7D-L21F2002➁➂-➃➄ Green G* Flush (Top) 2NO 2NO HW7D-L21F2020➁➂-➃➄ Flush (Bot- Red R* Flush (top) tom) 1NO 1NC HW7D-L21F1001➁➂-➃➄ Extended (bottom) Blue S* 1NO 1NO HW7D-L21F1010➁➂-➃➄ White W Transformer 1NO-1NC 1NO-1NC HW7D-L21F1111➁➂-➃➄ Yellow Y* 2NO 2NC HW7D-L21F2002➁➂-➃➄ * Only available for LED Type 2NO 2NO HW7D-L21F2020➁➂-➃➄ illumination. 1NO 1NC HW7D-L22F1001➁➂-➃➄ 1NO 1NO HW7D-L22F1010➁➂-➃➄ ➃Pushbutton Color Code Full Voltage 1NO-1NC 1NO-1NC HW7D-L22F1111➁➂-➃➄ Color Code 2NO 2NC HW7D-L22F2002➁➂-➃➄ Top Green GR Flush (Top) 2NO 2NO HW7D-L22F2020➁➂-➃➄ Bottom Red Extended (Bottom) 1NO 1NC HW7D-L22F1001➁➂-➃➄ Top White WB 1NO 1NO HW7D-L22F1010➁➂-➃➄ Bottom Black Transformer 1NO-1NC 1NO-1NC HW7D-L22F1111➁➂-➃➄ 2NO 2NC HW7D-L22F2002➁➂-➃➄➄Engraving Codes 2NO 2NO HW7D-L22F2020➁➂-➃➄Engraving Code No Engraving Blank 1. *Interlock type prevents both top and bottom buttons from being pressed simultaneously. 2. Clear silicon rubber cover part number HW9Z-D7D. I/ON Top 1 O/OFF Bottom www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-85 Interlock* Momentary ø22mm - HW Series Oiltight Switches & Pilot Devices Contact Arrangement Chart Contact Arrangement Contact Block Top Button Bottom Button Mounting Top Button Bottom Button Contact Code Type Normal Push Normal Push Position 1NO X A3 1NO 1NO 1010 2NO X 1NO X 1NO 1NC 1001 2NC X 1NC X 1NC 1NO 0110 2NO X 1NC X 1NC 1NC 0101 2NC X 1NO X 2NO X 1NO 2NO 1020 3 Dummy 4NO X 1NO X 2NO X 1NO 1NO-1NC 1011 3 Dummy 4NC X 1NO X 2NC X 1NO 2NC 1002 3 Dummy 4NC X 1NC X 2NO X 1NC 2NO 0120 3 Dummy 4NO X 1NC X 2NO X 1NC 1NO-1NC 0111 3 Dummy 4NC X 1NC X 2NC X 1NC 2NC 0102 3 Dummy 4NC X 1NO X 2NO X 2NO 1NO 2010 3NO X 4 Dummy 1NO X 2NC X 2NO 1NC 2001 3NO X 4 Dummy 1NO X 2NO X 1NO-1NC 1NO 1110 3NC X 4 Dummy 1NO X 2NO X 1NO-1NC 1NC 1101 3NC X 4 Dummy 1NC X 2NO X 2NC 1NO 0210 3NC X 4 Dummy 1. Transformers can have two or four contact blocks only. 2. Contact blocks 1 and 3 are actuated by the top button. Contact blocks 2 and 4 are actuated by the bottom button. A3-86 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Contact Arrangement Chart con’t Contact Arrangement Contact Block Top Button Bottom Button Mounting Top Button Bottom Button Contact Code Type Normal Push Normal Push Position A3 1NC X 2NC X 2NC 1NC 0201 3NC X 4 Dummy 1NO X 2NO X 2NO 2NO 2020 3NO X 4NO X 1NO X 2NO X 2NO 1NO-1NC 2011 3NO X 4NC X 1NO X 2NC X 2NO 2NC 2002 3NO X 4NC X 1NO X 2NO X 1NO-1NC 2NO 1120 3NC X 4NO X 1NO X 2NO X 1NO-1NC 1NO-1NC 1111 3NC X 4NC X 1NO X 2NC X 1NO-1NC 2NC 1102 3NC X 4NC X 1NC X 2NO X 2NC 2NO 0220 3NC X 4NO X 1NC X 2NO X 2NC 1NO-1NC 0211 3NC X 4NC X 1NC X 2NC X 2NC 2NC 0202 3NC X 4NC X Contact Block Mounting Position Example 4 2 3 1 With Pilot Light (transformer type) www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-87 ø22mm - HW Series Oiltight Switches & Pilot Devices Dual Pushbutton Switches (Sub-Assembled) Contact Blocks + Mounting Adaptor + Operator + Lens = Complete Part A3 Part Numbers: Contact Blocks Part Numbers: Operators Description Part Number Style Type Button Style Part Number Flush (top) HW7D-011➃-➄ Flush (bottom) 1NO 1NC Flush (top) Extended HW7D-012➃-➄ (bottom) Standard HW-F10 HW-F01 Fingersafe (IP20) HW-F10R (early make) HW-F01R (late break) Flush (top) HW7D-021➃-➄Spring-Up HW-G10 HW-G01 Flush (bottom) Terminal HW-G10R (early make) HW-G01R (late break) Contacts HW-G10-MAU (gold contacts) HW-G01-MAU (gold contacts) Flush (top) Extended HW7D-022➃-➄Exposed Screw HW-C10 HW-C01 (bottom) Terminal Contacts HW-C10R (early make) HW-C01R (late break) Dummy Block TW-DB ➃Pushbutton Color Code➄Engraving Codes 1. All assembled part numbers in catalog include standard (HW-F...) contacts. (excep Color Code Engraving Code unibody) No Engraving Blank Top Green 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing GR I/ON Top Bottom Red an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 1 O/OFF Bottom 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-component Top White WB 4. All contacts (including exposed screw) are UL, CSA, and IEC compliant and carry Bottom Black the CE mark. Part Numbers: Contact Block Mounting Adaptor Part Numbers: Lamp Circuit Components (safety lever lock included) Style Description Terminals Part Number Appearance Part Number For use with HW-CBL on all Non-Illuminated illuminated pushbutton units. Lead Holder HW-LH3 1.Used to mount One required for each deck (pair) of contacts. contact blocks to HW-CB2C operator (first Fingersafe HW-DA1FB Dummy Block pair only). with Exposed HW-DA1B For use with odd 2. IDEC strongly recom- number of contacts. Full Voltage Spring Up HW-GA1 mends using the safety Adaptor Illuminated (with lever lock (included) to Pilot Light) Fingersafe TW-DA1FB prevent heavy vibration Full Voltage For use with even or maintenance per- number of contacts. HW-CBL Adaptor Exposed TW-DA1B sonnel from unlocking contacts. 120VAC TW-F126B 240VAC Fingersafe TW-F246B 480VAC TW-F486B Part Numbers: Lamps/Lens Transformer Unit 120V HW-T126 240V Spring Up HW-T246 (6V secondary Type Voltage Part Number 480V HW-L486 voltage) 6V AC/DC LSTD-6➁ LED 120V TW-T126B 12V AC/DC LSTD-1➁240V Exposed TW-T246B 480V TW-T486B 24V AC/DC LSTD-2➁ 120V AC LSTD-H2➁DC-DC Converter 110VDC HW-L16D 240V AC LSTD-M4➁ HW-GA1 “Dummy Block with full voltage adaptor” does not 6.3V AC/DC IS-6 Incandescent require the use of HW-LH3. 12V AC/DC IS-12 24V AC/DC IS-24 Part Numbers: Anti-Rotation Ring LED Color Code 30V AC/DC IS-30 Appearance Part Number Color Code Color Code Non-Illuminated Amber A Blue S HW9Z-B7B HW9Z-RL Green G White W Red R Yellow Y Use with notched panel cut- Illuminated HW9Z-L7W out to prevent unit rotation. 1. In place of ➁, specify the LED Color Code from table on right. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. A3-88 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Lens Lamps Flush Extended Flush Flush Interlock Momentary Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Mono Lever Switches (Assembled) Part Numbers: Mono Lever Switches No. of Description Part Number Positions HW1M-F1010-20 A3 HW1M-F2020-20 HW1M-F0101-20 2 HW1M-F0202-20 HW1M Standard Lever HW1M-F0101-40 Part Number Guide HW1M-F0202-40 ➀➁➂ HW1M-F1111-22N9 4 L F 0 1 0 1 20 HW1M- – HW1M-F2222-22N9 up right down left HW1M-LF1010-20 Type Lever Action Circuit Number HW1M-LF2020-20 Description Code Remarks HW1M-LF0101-20 2 Standard (blank) Interlocking mecha- HW1M-LF0202-20 HW1M-L nism prevents inad- ➀ Type Interlocking Lever Interlocking L vertent activation HW1M-LF0101-40 Maintained 1 HW1M-LF0202-40 Fill in desired action for Spring 2 each position: ➁ Lever Action HW1M-LF1111-22N9 Up/Right/Down/Left 4 Blocked 0 HW1M-LF2222-22N9 20 See Circuit Diagrams 40 ➂ Circuit Number below 22N9 Circuit Diagrams 2 Position Left/Right 2 Position Up/Down Contact Contact Position Position Circuit Circuit Mounting Mounting Number Number No. Left Center Right No. Down Center Up 1HW-F10 X 0 0 1HW-F10 X 0 0 20 20 2HW-F10 0 0 X 2HW-F10 0 0 X 1HW-F10 X 0 0 1HW-F10 X 0 0 2HW-F10 0 0 X 2HW-F10 0 0 X 40 40 3HW-F10 X 0 0 3HW-F10 X 0 0 4HW-F10 0 0 X 4HW-F10 0 0 X 3 Position 4 Position Contact Contact Position Position Circuit Circuit Mounting Mounting Number Number No. Down Left Center Up Right No. Down Left Center Up Right 1HW-F01 0 O 0 0 X 1HW-F01 0 O 0 0 X 30 2HW-F01 X 0 0 O 0 2HW-F01 X 0 0 O 0 22N9 3HW-F10 0 X 0 0 O 3HW-F10 0 X 0 0 O 4HW-F10 O 0 0 X 0 Other circuit arrangements available, contact IDEC for details. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-89 ø22mm - HW Series Oiltight Switches & Pilot Devices Mono Lever Switches (Sub- Assembled) Contact Blocks + Mounting Adaptor + Anti-Rotation Ring + Operator = Complete Part A3 Part Numbers: Operators # of Appearance Description Part Number Positions Maintained Up/Down HW1M-1010 Standard Spring return Up/Down HW1M-2020 2 Maintained Left/Right HW1M-0101 Spring return Left/Right HW1M-0202 Maintained, 4 position HW1M-1111 4 Spring return, 4 position HW1M-2222 Interlocking Maintained Up/Down HW1M-L1010 Spring return Up/Down HW1M-L2020 2 Maintained Left/Right HW1M-L0101 Spring return Left/Right HW1M-L0202 Maintained, 4 position HW1M-L1111 4 Spring return, 4 position HW1M-L2222 Part Numbers: Contact Block Mounting Adaptor Part Numbers: Contact Blocks (safety lever lock included) Description Part Number Appearance Part Number 1NO 1NC Standard Fingersafe (IP20) HW-F10 HW-F01 HW-CB2C HW-F10R HW-F01R (early make) (late break) 1. Used to mount contact blocks to operator Spring-Up Terminal Contacts (first pair only). HW-G10 HW-G01 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or HW-G10R HW-G01R maintenance personnel from unlocking contacts. (early make) (late break) Exposed Screw Terminal Part Numbers: Anti-Rotation Ring Contacts Appearance Part Number HW-C10 HW-C01 HW-C10R HW-C01R (early make) (late break) HW9Z-RL Dummy Block 1. Use with notched panel cutout to prevent unit rotation. TW-DB 2. Not required when using HW series nameplates See page A3-96. Part Numbers: Replacement Parts 1. All assembled part numbers in catalog include Item Part Number standard (HW-F...) contacts. 2. Assembled units with spring-up terminals (HW- Black Cap G...) can be ordered by removing an “F” from the HW9Z-CPM part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) Boot must be ordered as sub-components. HW9Z-BLM (Ţts standard type operator only) A3-90 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Pushbutton Selectors (Assembled) Part Numbers: 2–Position Pushbutton Selectors Operator Position Part Number A3 Contacts Mounting Left Right 1 HW-F10 0 X 0 0 2NO HW1R-2DF20-① 2 HW-F10 0 0 0 X 1 HW-F10 0 X 0 0 2 HW-F10 0 0 0 X 2NO-2NC HW1R-2DF22N1-① 3 HW-F01 X 0 X X 4 HW-F01 X X X 0 1 HW-F10 0 X 0 0 2 HW-F10 0 0 0 X 2NO-2NC HW1R-2EF22N1-① 3 HW-F01 0 0 X X 4 HW-F01 X X 0 0 1 HW-F10 0 0 0 X 2 HW-F10 0 X 0 0 2NO-2NC HW1R-2FF22N1-① 3 HW-F01 0 0 X 0 4 HW-F01 X 0 0 0 1. Available only with momentary pushbutton and maintained selector. 2. In place of ➀, specify the button color code from table below 3. Other contact arrangements available. Contact IDEC for details. 4. All assembled parts use flush buttons. 5. Normal position refers to the button flush with the selector ring. 6. Depressed position refers to the button being pushed in. ① Button Color Code Color Code Black B Green G Red R Blue S White W Yellow Y Grey N www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-91 Normal Depressed Normal Depressed ø22mm - HW Series Oiltight Switches & Pilot Devices Pushbutton Selectors (Partial-Assemblies) Contact Assembly + Operator/Button = Complete Part A3 Part Numbers: Operators Appearance Description Part Number Cam D HW1R-2D-① Cam E HW1R-2E-① HW1R-2F-①Cam F In place of ① specify Button Color Code. Part Numbers: Contact Assemblies Style Contacts Part Number Standard Fingersafe Contacts 1NO HW-CBF10 1NC HW-CBF01 1NO/1NC HW-CBF11 2NO HW-CBF20 2NC HW-CBF02 2NO/2NC HW-CBF22 Spring Up Terminal Contacts 1NO HW-CB10 1NC HW-CB01 1NO/1NC HW-CB11 2NO HW-CB20 2NC HW-CB02 2NO/2NC HW-CB22 ① Button Color Code Color Code Black B Green G Red R Blue S White W Yellow Y Grey N A3-92 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Pushbutton Selectors (Sub-Assembled) Contact Mounting Contact Blocks + + Anti-Rotation Ring + Operator + Button = Complete Part Adaptor A3 Part Numbers: Operators Part Numbers: Contact Blocks Appearance Description Part Number Description Part Number Cam D 1NO 1NC HW1R-2D Standard Fingersafe (IP20) Cam E HW1R-2E HW-F10 HW-F01 Cam F HW1R-2F HW-F10R HW-F01R Cam N HW1R-2N (early make) (late break) Part Numbers: Buttons Description Part Number Spring-Up Terminal Contacts HW-G10 HW-G01 Round Flush HW-G10R HW-G01R (early make) (late break) HW1A-B1-① Exposed Screw Terminal Contacts In place of ① specify Button Color Code. HW-C10 HW-C01 HW-C10R HW-C01R (early make) (late break) Part Numbers: Anti-Rotation Ring Appearance Part Number Dummy Block HW9Z-RL TW-DB 1. Use with notched panel cutout to prevent unit rotation. 1. All assembled part numbers in catalog include 2. Not required when using HW series name- standard (HW-F...) contacts. plates See page A3-96. 2. Assembled units with spring-up terminals (HW- G...) can be ordered by removing an “F” from the Part Numbers: Contact Block Mounting Adaptor part number (Ex. HW1B-M1F11-R becomes (safety lever lock included) HW1B-M111-R). Appearance Part Number 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. ① Button Color Code HW-CB2C Color Code Black B Green G 1. Used to mount contact blocks to operator Red R (first pair only). 2. IDEC strongly recommends using the safety lever Blue S lock (included) to prevent heavy vibration or White W maintenance personnel from unlocking contacts. Yellow Y Grey N www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-93 ø22mm - HW Series Oiltight Switches & Pilot Devices Operator Truth Tables HW Pushbutton Selector Switches - Cam D Operator Position Left Right Mounting Contact A3 Position Button Free Button Pressed Button Free Button Pressed Left O X O O HW-F10 (NO) Right O O O X Left X O X X HW-F01 (NC) Right X X X O Left O X O O HW-F10R (NO-EM) Right O O O X Left X O X X HW-F01R (NC-LB) Right X X X O HW Pushbutton Selector Switches - Cam E Operator Position Left Right Mounting Contact Position Button Free Button Pressed Button Free Button Pressed Left O X O O HW-F10 (NO) Right O O O X Left O O X X HW-F01 (NC) Right X X O O Left X X O O HW-F10R (NO-EM) Right O O X X Left X O X X HW-F01R (NC-LB) Right X X X O HW Pushbutton Selector Switches - Cam F Operator Position Left Right Mounting Contact Position Button Free Button Pressed Button Free Button Pressed Left O O O X HW-F10 (NO) Right O X O O Left O O X O HW-F01 (NC) Right X O O O Left X X O X HW-F10R (NO-EM) Right O X X X Left X X X O HW-F01R (NC-LB) Right X O X X HW Pushbutton Selector Switches - Cam N Operator Position Left Right Mounting Contact Position Button Free Button Pressed Button Free Button Pressed Left O X O X HW-F10 (NO) Right O X O X Left O O X O HW-F01 (NC) Right X O O O Left X X O X HW-F10R (NO-EM) Right O X X X Left X O X O HW-F01R (NC-LB) Right X O X O A3-94 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Contactor Reset Button Part Numbers: Reset Buttons (Assembled) Appearance Plastic Bezel Metal Bezel A3 (Blank) HW1B-M1RS-①T HW4B-M1RS-①T ① Button Color Code Color Code Black B Engraved “R” HW1B-M1RS-①T-ENG-R HW4B-M1RS-①T-ENG-R Green G Grey N 1. In place of ① specify Button Color Code. Red R 2. 5.1” (130mm) overall length. Blue S 3. 16mm flat base for easy alignment White W Yellow Y Sub-Assemblies Rod + Operator + Button = Complete Part Part Numbers: Button Part Numbers: Rod Appearance Part Number Appearance Part Number HW9Z-RS-TK2141 HW1A-B1-① ① Button Color Code In place of ① specify Button Color Code from table. Color Code Black B Green G Part Numbers: Operator Grey N Appearance Plastic Metal Red R Blue S White W Yellow Y HW1B-MO HW4B-MO www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-95 Y C N S E T ø22mm - HW Series Oiltight Switches & Pilot Devices Nameplates — HW Series Part Numbers: Nameplates HWAM–Black Plastic HWAQ–Black Plastic HWAS–Black Plastic HWAV–Yellow Plastic A3 29mm 29mm 45mm STOP OFF ON 14.5mm Part Number Part Number Part Number Part Number Nameplate (blank engraving HWAM-OB HWAQ-OB HWAS-OB HWAV-O plate included) Nameplate HWAV-27* HWAM-➀HWAQ-➀HWAS-➀† (engraved) HWAV5-27 HWNP Dimensions Additional Insert HWNP-O HWNP-O (blank) 12mm Additional Insert HWNP-➀HWNP-➀ (engraved) 27mm 1. In place of ➀, insert either the standard legend code from table below or custom engraving delimited by “ “. 2. Standard engravings are available at no charge. 3. * HWAV-27 comes engraved “Emergency Stop” as shown in drawing. † 4. HWAV5-27 for 80mm diameter jumbo mushroom comes engraved “Emergency Stop” as shown in drawing. Standard Legend Codes Pushbuttons Pushbuttons/Selector Switches Selector Switches Legend Code Legend Code Legend Code Legend Code Legend Code AUTO-MAN-OFF 301 AUTO 101 AUTO-MAN 201 AUTO-OFF-MAN 302 OPEN 116 CLOSE 102 CLOSE-OPEN 202 CLOSE-OFF-OPEN 303 OUT 117 DOWN 103 DOWN-UP 203 DOWN-OFF-SLOW 304 RAISE 118 EMERG.STOP 104 FAST-SLOW 204 REV-FOR 216 FAST-OFF-SLOW 305 RESET 119 FAST 105 FOR-REV 205 RUN-JOG 217 FOR-OFF-REV 306 REVERSE 120 FORWARD 106 HAND-AUTO 206 RUN-SAFE 218 LEFT-OFF-RIGHT 307 RUN 121 HAND 107 HIGH-LOW 207 SAFE-RUN 219 LOWER-OFF-RAISE 308 SLOW 122 HIGH 108 JOG-RUN 208 SLOW-FAST 220 OFF-MAN-AUTO 309 START 123 IN 109 LEFT-RIGHT 209 START-STOP 221 OFF-SLOW-FAST 310 STOP 125 INCH 110 LOWER-RAISE 210 STOP-START 222 OFF-1-2 311 TEST 126 JOG 111 MAN-AUTO 211 UP-DOWN 223 OPEN-OFF-CLOSE 312 UP 127 LOW 112 OFF-ON 212 OI (Int’l OFF ON) 250 SLOW-OFF-FAST 313 I (Int’l On) 150 LOWER 113 ON-OFF 213 SUMMER-OFF-WINTER 314 O (Int’l Off) 151 OFF 114 OPEN-CLOSE 214 UP-OFF-DOWN 315 EMO 152 ON 115 RAISE-LOWER 215 1-OFF-2 316 HAND-OFF-AUTO 317 1. To order engraved nameplates, add legend code to nameplate part number. 2. Character height based on the number of characters and size of nameplate. Standard character size is 3/16". 3. Nameplates with standard legends are the same list price as blank nameplates. 4. Nameplates have built-in anti-rotation feature for use with notched panel cut-outs. Additional anti-rotation ring (HW9Z-RL) is not necessary. A3-96 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G O R P E M E Switches & Pilot Devices 30mm 30mm 45mm Ø 60mm Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Nameplates Order Form — HW Series Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. To insure engraving accuracy, fax it to your IDEC representative or Distributor. Your Company: IDEC Rep/Distributor Contact: Name: PO number (if known): Telephone: IDEC Rep/Distributor Phone: A3 Fax & Email IDEC Rep/Distributor Fax & Email HWAM Nameplate Step 1. 7/64” 11 characters max Choose Letter Size - 7/64” or 1/8”. Engraving Letter (for 7/64” size letters) Check the box for the letter size you want. Size Location Then write your lettering in box below checkboxes. Note: 1/8” size letters cannot 1/8” 9 characters max Letter exceed 9 characters. (for 1/8” size letters) Size Step 2. Sample Letter Sizes Specify Quantity. 7/64” Letters: A B C D Enter the number of 1/8” Letters: A B C D nameplates desired in Qty the box on the right. 1 2 3 4 5 6 7 8 9 10 11 HWAQ Nameplate Step 1. 7/64” 11 characters max Choose Letter Size - 7/64” or 1/8”. Letter Engraving (for 7/64” size letters) Check the box for the letter size you want. Size Location Then write your lettering in box below checkboxes. Note: 1/8” size letters cannot 1/8” 9 characters max Letter exceed 9 characters. (for 1/8” size letters) Size Step 2. Sample Letter Sizes Specify Quantity. 7/64” Letters: A B C D Enter the number of nameplates desired in 1/8” Letters: A B C D Qty the box on the right. 1 2 3 4 5 6 7 8 9 10 11 HWAS Nameplate Step 1. 3/32” 20 characters maximum Choose Letter Size - 1/8” Letter Engraving Location A (for 3/32” size letters) or 3/32”. Size Check the box for the letter size you want. Then write your 1/8” 14 characters maximum lettering in box below check- Letter (for 1/8” size letters) Size boxes. Note: 1/8” size letters cannot exceed 14 characters. Engraving Location B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Step 2. Step 3. Sample Letter Sizes Specify Quantity. Specify Location. 3/32” Letters: A B C D Enter the number of Enter the location of 1/8” Letters: A B C D nameplates desired in engraving (A or B), in Qty Location box on the right. box on the right. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-97 ø22mm - HW Series Oiltight Switches & Pilot Devices Accessories — HW Series Appearance Description/Usage Part Number Metallic tool used to tighten the plastic locking ring when Locking Ring Wrench MW9Z-T1 installing the HW series unit in a panel A3 Lamp/LED Removal Tool Rubber tool makes lamp/LED removal easier. OR-55 for notched panel HW9Z-RL Prevents rotation of switches in panel. cutout (standard) Anti-Rotation Ring (included with all assembled switches) for round panel cutout LW9Z-L Rubber Mounting Hole Black rubber plug Ţlls unused mounting holes in panel. OB-31 Plug For plugging unused mounting holes in the panel. Tighten the attached locking ring to a torque of 12 kfg-cm maxi- Metallic Mounting Hole mum LW9Z-BM Plug Degree of protection: IP66 To prevent contact between adjacent lead wires when Barrier HW-VL1 control units are tightly mounted Used to cover and protect pushbuttons Flush Pushbuttons OC-31 Pushbutton Clear Boot Operating temperature: –50 to +60°C Extended Pushbuttons OC-32 Plastic hinged cover to protect pushbuttons or selector switches. (Not intended for E-Stops) HW9Z-KL1 Padlock Cover Degree of protection: IP65 Tab Terminal Adapter Tab #250 (6.35 x 0.8mm): Single tab TW-FA1 Used to mount round HW series control unit (except Adaptor (22mm to 30mm) Jumbo Mushroom, unibody, and square units) into a HW9Z-A30 30mm panel cut-out. (includes both pieces) Used to prevent contact mounting lever from moving due Replacement Safety Lever to heavy vibration or panel maintenance. HWLS-TK1971 Lock (included with all Contact Block Mounting Adaptors) Reset Rod for Contactors 5” rod used with HW1B-M0. See Contactors Section D for HW9Z-RS-TK2141 more information. Overload Replacement Operator Provided with operator. Insert between HWM-WASHER bezel and locking ring. Washer Standard (plastic) HW9Z-LN Plastic locking nut comes with all HW operators & Replacement Locking Ring assemblies. Optional (metal) HW9Z-LNM HW9Z-K1 (spring return) Switch Cover (Square) Used only with round or square ţush pushbuttons. HW9Z-K11 (maintained cover) Replacement Keys Pair of Keys (#231) HW9Z-SKP A3-98 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Appearance Description/Usage Part Number Replacement Lens HW Illuminated Unibody Replacement Lens HWLV-LENSR Replacement Jumbo HW1A-P5① A3① = (A, G, R, S, W, Y) Dome Lens Polycarbonate Replacement Lens Replacement Jumbo HW9Z-PP5C Diffusing Lens Replacement LED Lamps LSTDB-2①Replacement LED Lamp for HW Jumbo Dome① = (A, G, R, S, W, Y) Rubber Cover for Dual Clear Silicon rubber cover HW9Z-D7D Pushbuttons Plastic barrier. Used when mounting the HW7 units Barrier for Dual on 30mm horizontal centers, to prevent possible HW-VG1 Pushbuttons interconnections between adjoining terminals. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-99 Lock ø22mm - HW Series Oiltight Switches & Pilot Devices Dimensions — HW Series Non-Illuminated Pushbuttons Panel Thickness 0.8mm to 6.mm Gasket * Round: 23.6mm M3.5 Terminal Screws Locking Ring A3 * Square: 24.8mm * * D1 D1 0.5mm 32mm 50.2mm D2 70.2mm 13mm Round Square D1 D1 D3 32mm D1 = 13mm D2 = 19mm D3 = 23.2mm D1 D3 30mm Monolever 0.21" (8mm) 1.18" (30mm) 24 deg. 0.90" (23mm) 2.83" (72mm) Pilot Lights Panel Thickness 0.8mm to 6.0mm Gasket M3.5 Terminal Screws Locking Ring 29.6mm 5mm 44.7mm 7mm M3.5 Terminal Screws 29.6mm 72.1mm 7mm 17.5mm A3-100 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC 29mm 29mm Switches & Pilot Devices 25mm 24mm 40.4mm 29.6mm 40mm 29mm 40mm 29mm Switches & Pilot Devices Lock Oiltight Switches & Pilot Devices ø22mm - HW Series Dimensions con’t Jumbo Mushroom Pushbutton HW1B-M5 HW1B-V5 Ø2.36in.(Ø60.0mm) 2.36" (60mm) A3 1.33" (34mm) 1.15in.(29.2mm) Illuminated Pushbuttons Panel Thickness: 0.8mm to 6.0mm Gasket Locking Ring Mushroom Extended with Full Shroud D1 0.5mm 1 block 50.2mm Mushroom 29mm 18.5mm 3 blocks 70.2mm 23.2mm 2 blocks 65.8mm 4 blocks 85.8mm D1 W/ Transformer Extended D1 D1 2 blocks 89.5mm Mushroom 40mm 23.2mm 4 blocks 109.5mm 18.5mm Square 24V AC/DC Round M3.5 Terminal Screws W/ Dummy Block & W/ Full Voltage Adaptor Full Voltage Adaptor M3.5 Terminal Screws W/ Transformer 30mm D1 = 0.51" 13mm www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-101 25mm 40mm 23.5mm 29mm 40mm 29.6mm 29.5mm 23.4mm 28.8mm k Lock Lock oc L ø22mm - HW Series Oiltight Switches & Pilot Devices Dimensions con’t Unibody Illuminated Non-Illuminated Panel Thickness 0.8mm to 6.0mmPanel Thickness 0.8mm to 6.0mm A3 Gasket Gasket Locking Ring M3.5 Terminal Screws Locking Ring M3.5 Terminal Screws 60mm 46mm 11.5mm 11.5mm 14mm 14mm 48mm 32mm 63mm 32mm Selector Switches Panel thickness: 0.8mm to 6.0mm Gasket M3.5 Terminal Screws Locking Ring 0.5mm 1-2 blocks 48.5mm 29.4mm 3-4 blocks 68.5mm 21mm Illuminated Selector Switches Pushlock Key Reset Panel Thickness 0.8mm~6mm Gasket Panel thickness: 0.8mm to 6.0mm Lock Nut Rubber Washer Locking Ring 0.5mm 13mm 30mm 48.5mm 21mm 2 blocks 89.5mm 50.3mm 32mm 4 blocks 109.5mm 49.4mm Key Switches Panel thickness: 0.8mm to .0mm Gasket M3.5 Terminal Screws Locking Ring 0.5mm 1-2 blocks 48.5mm D1 D1 = 13mm 29.4mm 3-4 blocks 68.5mm 30.5mm A3-102 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC 29mm 29mm ø 40mm Switches & Pilot Devices 40mm 28.8mm 17mm 25mm 25mm 17mm 37mm 25mm 40mm 40.4mm Switches & Pilot Devices HW HW HW HW +0.4 0 ø22.3 Oiltight Switches & Pilot Devices ø22mm - HW Series Dimensions con’t Dual Pushbutton Switches Without Pilot Light A3 49.4 (2 contacts) 69.4 (3 or 4 contacts) Panel Thickness 0.8 to 6 Without Button With Button Markings Safety Lever Lock Locking Ring Markings (I/ON and O/OFF) ON OFF Rubber Gasket 0.5 29.8 29.8 14.5 20 With Pilot Light • Full Voltage Ful Voltage Adapter • The depth of 3-contact type depends on the combination of contact blocks at top and bottom pushbuttons. (Bottom Button) Top Button 1 contact block 2 contact blocks (Top Button) Bottom Button 2 contact blocks 1 contact block Depth 89.4 mm 69.4 mm 69.4 (2 contacts), 89.4 (4 contacts) (Note) •Transformer (240V maximum) • Transformer (480V) Transformer Transformer, DC-DC Converter 79.5 (2 contacts), 99.5 (4 contacts) 89.5 (2 contacts), 109.5 (4 contacts) Mounting Hole Layout R0.8 max. +0.2 • The 3.2 mm recess is for preventing rotation and is not necessary when a ∗3.2 0 nameplate or anti-rotation ring is not used. • When using the safety lever lock, determine the vertical spacing in consid- eration of convenience for installing and removing the safety lever lock. • Recommended vertical spacing: 100 mm 30 • The minimum mounting centers are applicable to switches with one layer of contact blocks (two contact blocks). When two layers of contact blocks are mounted, determine the minimum mounting centers in consideration of convenience for wiring. All dimensions in mm. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-103 55 ∗∗ +0.4 24.1 0 41.4 54.8 54.8 R 66.5mm ø 22.2mm ø 11.6mm ø22mm - HW Series Oiltight Switches & Pilot Devices Dimensions con’t Jumbo Dome Pilot Lights Dimensions Mounting Hole Layout LED Lamp LSTDB All dimensions in mm. Panel Thickness 1 to 5 Base BA9S/13 +0.2 R0.8 max. Light blue: 3.2 0 Illumination Color +0.4 LSTDB ø22.3 0 M3.5 Terminal Screw A3 20.4 Locking Ring Incandescent Lamp LSB Rubber Gasket Base BA9S/13 0.5 34.4 50.5 85 ±2 27 Accessory Dimensions LW9Z-BM OB-31 HW9Z-RL OR-55 Metallic Mounting Hole Plug Rubber Mounting Hole Plug Anti-Rotation Ring Lamp/LED Removal Tool ø 25.8mm ø 29mm TOP ø 14mm Gasket Lock Nut ø 25mm 59mm 1.5mm HW9Z-D7D HW-VG1 MW9Z-T1 Dual Pushbutton Rubber Cover Dual Pushbutton Barrier Locking Ring Wrench 22.5 33 110 1.5 20 HW-VL1 Mounting Hole Layout HW9Z-KL1 Barrier Padlock Cover 82.5mm Panel Thickness 0.8mm - 3.2mm 30mm 20mm 1.5mm 30mm 24mm Ø 3.5mmm {Note 1} Waterproof Gasket HWLS-TK1971 Thickness 0.5mm 29.5mm Pad Lock Hole Safety Lever Lock Push to Set 30mm ø 8mm Note 1: Mushroom Button 40mm Type: 40mm or more 0.49" Note 2: Pilot Light: 30mm minimum (12.5mm) The values represent the minimum mounting centers when one stack of contact blocks is used. When two 0.50" 0.31" stacks or an illuminated unit is used, refer to the (12.8mm) (8mm) dimensions and considerwiring accessibility to determine minimum mounting centers. A3-104 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC ø 22m m ø 29mm ø 28 ø 50mm ø 66 22.3mm Switches & Pilot Devices 70mm 58 12mm 3mm 93mm 3.5mm 45 45mm 3.5mm ø10.6 ±1 ø10 50mm 45mm minimum {Note 2} 85 +0.4 24.1 0 Switches & Pilot Devices ø22.2 ø90.0 Oiltight Switches & Pilot Devices ø22mm - HW Series Accessory Dimensions con’t HW9Z-KG1-TK2120 HW9Z-KG2-TK2120 64.0 38.0 36.5 48.0 A3 22.0 Gasket TOP Marking TOP Mark TOP Marking TOP Mark Locking Ring Locking Ring Operator Operator Panel Thickness: 1.2 to 4.0 mm Panel Thickness: 1.2 to 4.0 mm SpeciŢcation Charts — HW Series Rated Operational Power DC Voltage Inductive Resistive DC Voltages Voltage V 24 48 110 Voltage V 24 48 110 DC Voltages Current A 4 2 1.1 Current A 8 4 2.2 600V AC 120V AC AC Voltages AC Voltages 500V AC 500V AC 120V AC 480V AC 1.0 1.0 400V AC 480V AC 400V AC 380V AC 380V AC 240V AC 240V AC 0.5 0.5 0.2 0.2 600V AC 0.1 0.1 56 123 4 56 10 123 4 10 Current in A Current in A Conforming to IEC 947-5-1 Appendix C. Conforming to IEC 947-5-1 Appendix C. Utilization categories AC-15 and DC-13. Utilization categories AC-15 and DC-13. Operation rate: 1,800 op. hour Operation rate: 1,800 op. hour Load factor: 0.9 ± 0.05 Load factor: 0.4 ± 0.05 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-105 ø22.0 80.0 Millions of operating cycles 32.0 Millions of operating cycles ø76.1 ø22mm - HW Series Oiltight Switches & Pilot Devices HW Safety Precautions HW Series Safety Precautions • Turn off power to HW series control units before starting installa- For wiring, use wires of a proper size to meet voltage and current tion, removal, wiring, maintenance, and inspection of the products. requirements. Tighten the M3.5 terminal screws to a tightening Failure to turn power off may cause electrical shocks or Ţre haz- torque of 1.0 to 1.3 N·m. Failure to tighten terminal screws may cause ard. A3 overheating and Ţre. • To avoid the possibility of burning yourself, use the lamp holder tool when replacing lamps. HW General Instructions Panel Mounting Safety Lever Lock Remove the contact block assembly from the operator (for trans- IDEC strongly recommends using the safety lever lock (HW9Z-LS, yellow) to former type pilot lights, remove the transformer from the illumination prevent heavy vibration or maintenance personnel from unlocking the con- unit). Remove the locking ring from the operator. Insert the operator tact assembly. into the panel cut-out from the front, tighten the locking ring from the 1. HW series can be mounted vertically with a minimum spacing of 55 back, then install the contact block assembly to the operator. mm but spacing should be determined to ensure easy operation Removing and Installing the Contact Block Assembly (recommended minimum spacing: 100 mm). 1. To remove the operator from the contact block, turn the locking 2. Mount the control unit onto the panel, lock the lever, and push in lever in the direction of the arrow shown below. The operator can the safety lever lock to install. now be removed. 3. When the spacing is narrower than the recommended value, with 2. To reinstall, place the TOP markings on the operator and the con- the lever unlocked, mount the safety lever lock and insert the con- tact block mounting adapter in the same direction, and insert the tact unit to the operator. Then, lock the lever and strongly push in operator into the contact block mounting adapter. Then turn the the safety lever lock to install. locking lever in the opposite direction. 4. To remove the safety lever lock, insert a ţat screwdriver into the safety lever and push upwards. Removing and Installing the Safety Lever Lock Safety Lever Lock➀ Push Safety Lever Lock Lock Lever Remove Screwdriver➁ Install Operator➂ Lock Contact Block Panel Removing Installing Notes for Panel Mounting 1. When mounting the operator onto a panel, use the optional locking ring wrench (MW9Z-T1) to tighten the locking ring. Tightening torque must not exceed 2.0 N·m. Do not use pliers. Excessive tight- ening will damage the locking ring. 2. For the contact blocks and transformers housing LED and incan- descent lamps, make sure not to press the lamps too hard, other- wise the lamp socket may be damaged. Dual Pushbutton Instructions Replacement of Lens Removing • Remove the lens by inserting a screwdriver into the recess of the lens through the bezel. Installing • Install the lens in the recess between the buttons by pressing against the bezel. A3-106 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - HW Series Dual Pushbuttons Instructions con’t Replacement of Lamps Tightening Torque for Terminal Screws Lamps can be replaced by using the lamp holder tool (OR-55) from the front of Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3 N·m. the panel, or by removing the contact block assembly from the operator unit. Installation of LED Illuminated Units Removing the Lamps from the Front of the Panel When using full voltage type LED illuminated units, provide protection A3 Removal against electrical noise, if necessary. 1. To remove, slip the lamp holder tool onto the lamp head lightly. Applicable Wiring Then push slightly, and turn the 2 The applicable wire size is 2 mm maximum. (solid wire ş1.6 mm maxi- lamp holder tool counterclock- mum) One or two wires can be connected. wise. Applicable Crimping Terminal ø3.6 min. Installation 1. To install, insert the lamp head into the lamp holder tool, and hold the lamp as shown in the Ţgure below. 4 max. 5.5 min. Lamp Lamp Holder Tool Be sure to use an insulation tube or cover on the crimping part of the crimping terminal to prevent electrical shocks. Solid Wire 2. Place the pins on the lamp base to the grooves in the lamp socket. Lamp Base Insert the lamp and turn it clock- 8 max. wise. Note: When connecting wires to contact blocks or transformers in the direction shown below, keep the insulation stripping length 6.6 mm at the maximum. About Pushbutton Switches The pushbuttons cannot be Do not attempt removed or replaced! to remove the pushbuttons! Do not attempt to remove using a ţat screwdriver or Pushbuttons X1 X2 pincers, otherwise the push- buttons may be damaged. Installing the Rubber Cover Narrow Mounting When using the HW7D pushbuttons in places where the pushbuttons When mounting the units closely in a horizontal row on 30mm centers, are subjected to water splash or an excessive amount of dust, make use optional barriers to prevent interconnection between adjoining sure to use the HW9Z-D7D rubber boot (IP65) which is ordered sepa- terminals. The barriers can be attached simply by pressing them onto rately. the sides of contact blocks. Notes for Installing the Rubber Cover 30 30 Remove the gasket from the operator, and install the rubber boot on the operator. Pull out the seals of the rubber boot and place them around the operator sleeve as shown. Make sure that the seals are not twisted or tucked inside and that the gasket does not remain, other- wise the normal waterproof and dustproof characteristics are not ensured. ➀ Remove the gasket.➁ Install the rubber boot➂ Rubber boot is Barrier on the pushbuttons. installed. Seals When mounting transformer type Install illuminated units closely in a hori- Remove zontal row on 30-mm centers, insert solid wires or stranded wires into inside of the terminal X1 X2 X1 X2 screw on the transformer (see Ţgure on the right) to prevent Seals Gasket short circuit between adjoining Inside Inside terminals. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-107 ø1.6 max. 7.9 max. ø22mm - LW Series Oiltight Switches & Pilot Devices LW Series — Switches and Pilot Devices: 22mm A3 LW Series offer ţexibility in space-saving package Key features include: LW Series switches and pilot lights can be mounted collectively on 1.0" centers. Combined with pcb terminals and locking lever removable contacts, this eases manufacture of pre-fab pushbutton arrays (as • PC board mount, solder or screw terminal pictured). PC Board tracing/soldering of contacts can be done in tandem • Collective mounting saves space with panel cutting/operator installation. • Non-reţective lens • Highly visible marking plate All LW series units mount by means of a locking ring that comes on from •Tamper proof construction the rear of the panel, as such they can not be removed from outside the panel and are relatively tamperproof. • Light touch reduces strain • Gold or silver contacts Combining the snap action and tactile feel of miniature commercial • Removable contacts simplify wiring pushbuttons with the size and ruggedness of industrial pushbuttons, and facilitate PCB applications LW pushbuttons are a unique solution to many applications. Choose from standard silver contacts or low-level gold plated contacts. Terminals available in .110" solder tab, M3 screw, or pcb pins. UL Recognized Registration CSA CertiŢed File # E55996 No. J9551801 File No. LR21451 A3-108 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - LW Series SpeciŢcations Operating Temperature –25 to +60°C (without freezing) LED illuminated type: –25 to +50°C Storage Temperature –40 to +80°C Operating Humidity 45 to 85% RH A3 Contact Resistance 50mΩ maximum (initial value) Insulation Resistance 100MΩ minimum (500V DC megger) Between live part and ground: 2,500V AC, 1 minute Switch Unit Between terminals of different poles: 2,500V AC, 1 minute Dielectric Strength Between terminals of the same pole: 1,000V AC, 1 minute Illumination Unit Between live part and ground: 2,500V AC, 1 minute Vibration Resistance Operating extremes: 5 to 55Hz, Amplitude 1.0mm p-p 2 Damage limits: 1,000 m/sec (Approx. 100G) Shock Resistance 2 Operating extremes: 100 m/sec (Approx. 10G) Momentary: 1,000,000 operations minimum Mechanical Life Maintained: 500,000 operations minimum Selectors: 250,000 operations minimum Momentary: 100,000 operations minimum (at 1,800 operations/hour) Electrical Life Maintained/Selector: 100,000 operations minimum (at 900 operations/hour) Degree of Protection Watertight/oiltight IP65 (IEC Pub529) (except key selectors) Insulation Voltage 250VAC/DC Lenses polyarylate Materials Operators polyacetate Marking Plates acrylic resin .110" Solder tab/quick connect Terminal Style PC board terminal (gold contacts only) Screw terminal (DPDT units only) Contact Material Thermal Current Contact Rating Remarks 30VDC/0.1A resistive Minimum applicable load (reference value): 5V, 1mA AC/DC. Gold-clad cross-bar 3A (Applicable range is subject to the operating condition and load.) 125VAC/0.1A resistive 30VDC/2A resistive 30VDC/1A inductive 125VAC/3A resistive(50/60Hz) 125VAC/2A inductive (50/60Hz) AC inductive load: PF=0.6 to 0.7, Silver Contact 5A DC inductive load: L/R=7ms maximum. 125VDC/0.4A resistive 125VDC/0.2A inductive 250VAC/2A resistive(50/60Hz) 250VAC/1.5A inductive (50/60Hz) Lamp Ratings Voltage Current/Wattage UL Recognized CSA CertiŢed 6V AC/DC ±10% 17mA max File # E55996 File No. LR21451 12V AC/DC ±10% 11mA max 24V AC/DC ±10% 11mA max 120V AC ±10% 10mA max 240V AC ±10% 10mA max 6.3V AC/DC ±5% 1W Registration No. J9551801 12V AC/DC ±10% 1W 24V AC/DC ±10% 1W LED lamps contains a built-in current-limiting resistor and reverse polarity protection diode. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-109 Incandescent LED Contact Ratings Specifications ø22mm - LW Series Oiltight Switches & Pilot Devices Non-Illuminated Pushbuttons (Assembled) Part Numbers: LW1B/LW2B Pushbuttons Part Number Contact Style Contact Momentary Maintained (Latching) Material Solder/Tab PC Board Screw Solder/Tab PC Board Screw A3 SPDT LW1B-M1C1-①LW1B-M1C1V-①—LW1B-A1C1-①LW1B-A1C1V-①— Round Flush Gold DPDT LW1B-M1C2-①LW1B-M1C2V-①LW1B-M1C2M-①LW1B-A1C2-①LW1B-A1C2V-①LW1B-A1C2M-① 3PDT LW1B-M1C3-①LW1B-M1C3V-①—LW1B-A1C3-①LW1B-A1C3V-①— SPDT LW1B-M1C5-①—— LW1B-A1C5-①—— Silver DPDT LW1B-M1C6-①—LW1B-M1C6M-①LW1B-A1C6-①—LW1B-A1C6M-① 3PDT LW1B-M1C7-①—— LW1B-A1C7-①—— SPDT LW2B-M1C1-①LW2B-M1C1V-①—LW2B-A1C1-①LW2B-A1C1V-①— Square Flush Gold DPDT LW2B-M1C2-①LW2B-M1C2V-①LW2B-M1C2M-①LW2B-A1C2-①LW2B-A1C2V-①LW2B-A1C2M-① 3PDT LW2B-M1C3-①LW2B-M1C3V-①—LW2B-A1C3-①LW2B-A1C3V-①— SPDT LW2B-M1C5-①—— LW2B-A1C5-①—— Silver DPDT LW2B-M1C6-①—LW2B-M1C6M-①LW2B-A1C6-①—LW2B-A1C6M-① 3PDT LW2B-M1C7-①—— LW2B-A1C7-①—— SPDT LW1B-M2C1-①LW1B-M2C1V-①—LW1B-A2C1-①LW1B-A2C1V-①— Round Extended Gold DPDT LW1B-M2C2-①LW1B-M2C2V-①LW1B-M2C2M-①LW1B-A2C2-①LW1B-A2C2V-①LW1B-A2C2M-① 3PDT LW1B-M2C3-①LW1B-M2C3V-①—LW1B-A2C3-①LW1B-A2C3V-①— SPDT LW1B-M2C5-①—— LW1B-A2C5-①—— Silver DPDT LW1B-M2C6-①—LW1B-M2C6M-①LW1B-A2C6-①—LW1B-A2C6M-① 3PDT LW1B-M2C7-①—— LW1B-A2C7-①—— SPDT LW2B-M2C1-①LW2B-M2C1V-①—LW2B-A2C1-①LW2B-A2C1V-①— Square Extended Gold DPDT LW2B-M2C2-①LW2B-M2C2V-①LW2B-M2C2M-①LW2B-A2C2-①LW2B-A2C2V-①LW2B-A2C2M-① 3PDT LW2B-M2C3-①LW2B-M2C3V-①—LW2B-A2C3-①LW2B-A2C3V-①— SPDT LW2B-M2C5-①—— LW2B-A2C5-①—— Silver DPDT LW2B-M2C6-①—LW2B-M2C6M-①LW2B-A2C6-①—LW2B-A2C6M-① 3PDT LW2B-M2C7-①—— LW2B-A2C7-①—— SPDT LW1B-M3C1-①LW1B-M3C1V-①—LW1B-A3C1-①LW1B-A3C1V-①— Mushroom Gold DPDT LW1B-M3C2-①LW1B-M3C2V-①LW1B-M3C2M-①LW1B-A3C2-①LW1B-A3C2V-①LW1B-A3C2M-① 3PDT LW1B-M3C3-①LW1B-M3C3V-①—LW1B-A3C3-①LW1B-A3C3V-①— SPDT LW1B-M3C5-①—— LW1B-A3C5-①—— Silver DPDT LW1B-M3C6-①—LW1B-M3C6M-①LW1B-A3C6-①—LW1B-A3C6M-① 3PDT LW1B-M3C7-①—— LW1B-A3C7-①—— 1. In place of ①, specify Button Color Code from table below. 2. For sub-assembly part numbers, see page A3-111. 3. For dimensions, see page A3-120. 4. For accessories, see page A3-119. Part Numbers: Buzzers (IP20)① Button Color Code Part Number Color Code Style Solder Tab PCB Black B Green G Basic LW1Z-1X4 LW1Z-1X4V Red R With LED LW1Z-1X4D LW1Z-1X4DV Blue S White W 12-24V AC/DC+/- 10% Yellow Y 80 dB (at 0.1m) 7mA (DC), 20mA (AC) A3-110 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - LW Series Non-Illuminated Pushbuttons (Sub-Assembled) Contact Block + Operator + Button = Completed Unit A3 Part Numbers: Operators Part Number Style Momentary Maintained Round LW1B-M0 LW1B-A0 Square LW2B-M0 LW2B-A0 Mushroom LW1B-M0L LW1B-A0L Part Numbers: Buttons Part Number Type Flush Extended Round LW1A-B1-①LW1A-B2-① ① Button Color Code Color Code Square Black B LW2A-B1-①LW2A-B2-① Green G Red R Mushroom Blue S —LW1A-B3-① White W Yellow Y In place of ①, specify Button Color Code from table at right. Part Numbers: Contact Blocks Part Number Appearance Contact Material Contact Solder/Tab PC Board Screw SPDT LW-C1 LW-C1V — Gold DPDT LW-C2 LW-C2V LW-C2M 3PDT LW-C3 LW-C3V — SPDT LW-C5 — — Silver DPDT LW-C6 — LW-C6M 3PDT LW-C7 — — www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-111 ø22mm - LW Series Oiltight Switches & Pilot Devices LED and Incandescent Illuminated Pushbuttons (Assembled) Part Numbers: LW1L/LW2L Illuminated Pushbuttons (LED and Incandescent) Part Number Contact Style Contact Momentary Maintained (Latching) Material A3 Solder/Tab PC Board Screw Solder/Tab PC Board Screw SPDT LW1L-M1C10-➁LW1L-M1C10V-➁— LW1L-A1C10-➁LW1L-A1C10V-➁— Round Gold DPDT LW1L-M1C20-➁LW1L-M1C20V-➁LW1L-M1C20M-➁LW1L-A1C20-➁LW1L-A1C20V-➁LW1L-A1C20M-➁ 3PDT LW1L-M1C30-➁LW1L-M1C30V-➁— LW1L-A1C30-➁LW1L-A1C30V-➁— SPDT LW1L-M1C50-➁—— LW1L-A1C50-➁—— Silver DPDT LW1L-M1C60-➁— LW1L-M1C60M-➁LW1L-A1C60-➁— LW1L-A1C60M-➁ 3PDT LW1L-M1C70-➁—— LW1L-A1C70-➁—— SPDT LW2L-M1C10-➁LW2L-M1C10V-➁— LW2L-A1C10-➁LW2L-A1C10V-➁— Square Gold DPDT LW2L-M1C20-➁LW2L-M1C20V-➁LW2L-M1C20M-➁LW2L-A1C20-➁LW2L-A1C20V-➁LW2L-A1C20M-➁ 3PDT LW2L-M1C30-➁LW2L-M1C30V-➁— LW2L-A1C30-➁LW2L-A1C30V-➁— SPDT LW2L-M1C50-➁—— LW2L-A1C50-➁—— Silver DPDT LW2L-M1C60-➁— LW2L-M1C60M-➁LW2L-A1C60-➁— LW2L-A1C60M-➁ 3PDT LW2L-M1C70-➁—— LW2L-A1C70-➁—— SPDT LW1L-M3C10-➁LW1L-M3C10V-➁— LW1L-A3C10-➁LW1L-A3C10V-➁— Mushroom Gold DPDT LW1L-M3C20-➁LW1L-M3C20V-➁LW1L-M3C20M-➁LW1L-A3C20-➁LW1L-A3C20V-➁LW1L-A3C20M-➁ 3PDT LW1L-M3C30-➁LW1L-M3C30V-➁— LW1L-A3C30-➁LW1L-A3C30V-➁— SPDT LW1L-M3C50-➁—— LW1L-A3C50-➁—— Silver DPDT LW1L-M3C60-➁— LW1L-M3C60M-➁LW1L-A3C60-➁— LW1L-A3C60M-➁ 3PDT LW1L-M3C70-➁—— LW1L-A3C70-➁—— 1. In place of ➁, specify the Lens Color Code from table below. 2. Lamps must be ordered separately for all illuminated pushbuttons. 3. For marking plate size and engraving area, see page A3-124. 4. For sub-assembly part numbers, see page A3-113. 5. For dimensions, see page A3-120. 5. For accessories, see page A3-119. Part Numbers: Lamps (not included in assemblies)➁ Lens/LED Color Code Type Voltage Part Number Color Code 6V AC/DC±10% LSTD-6➁Amber A LED 12V AC/DC±10% LSTD-1➁Green G 24V AC/DC±10% LSTD-2➁Red R 120V AC±10% LSTD-H2➁Blue S 240V AC ±10% LSTD-M4➁White W Incandescent 6.3V AC/DC IS-6 Yellow Y 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of ➁, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diode. A3-112 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - LW Series LED and Incandescent Illuminated Pushbuttons (Sub-Assembled) Contact Block + Operator + Lamp + Lens = Completed Unit A3 Part Numbers: Operators Part Numbers: Lenses Part Number Part Number Style Type Momentary Maintained Flush Round Round LW1A-L1-➁ LW1L-M0 LW1L-A0 Square Square LW2A-L1-➁ LW2L-M0 LW2L-A0 Mushroom LW1A-L3-➁ Mushroom LW1B-M0L LW1B-A0L In place of ➁, specify Lens Color Code from table below. Part Numbers: Contact Blocks Part Number Appearance Contact Material Contact Solder/Tab PC Board Screw SPDT LW-C10 LW-C10V — Gold DPDT LW-C20 LW-C20V LW-C20M 3PDT LW-C30 LW-C30V — SPDT LW-C50 — — Silver DPDT LW-C60 — LW-C60M 3PDT LW-C70 — — Part Numbers: Lamps (not included in assemblies)➁ LED/Lens Color Code Type Voltage Part Number Color Code Amber A 6V AC/DC±10% LSTD-6➁ LED Green G 12V AC/DC±10% LSTD-1➁ Red R 24V AC/DC±10% LSTD-2➁ Blue S 120V AC±10% LSTD-H2➁ White W 240V AC ±10% LSTD-M4➁ Yellow Y Incandescent 6.3V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of ➁, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diode. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-113 ø22mm - LW Series Oiltight Switches & Pilot Devices LED and Incandescent Pilot Lights (Assembled) Part Numbers: LW1P/LW2P Pilot Lights Part Number Type Style Solder/Tab PC Board Screw A3 Round — — LW1P-1C00V-➁ Removable Terminal Pilot Light Square — — LW2P-1C00V-➁ Round — LW1P-10-➁LW1P-10M-➁ Unibody Square Pilot Light LW2P-10-➁— LW2P-10M-➁ 1. In place of ➁, specify the Lens Color Code from table below. 2. For marking plate size and engraving area, see page A3-124. 3. Lamps must be ordered separately, see table below. 4. For sub-assembly part numbers, see page A3-115. 5. For dimensions, see page A3-120. 6. For accessories, see page A3-119. Part Numbers: Lamps (not included in assemblies)➁ Lens/LED Color Code Type Voltage Part Number Color Code 6V AC/DC±10% LSTD-6➁Amber A LED 12V AC/DC±10% LSTD-1➁Green G 24V AC/DC±10% LSTD-2➁Red R 120V AC±10% LSTD-H2➁Blue S 240V AC ±10% LSTD-M4➁ White W Incandescent 6.3V AC/DC IS-6 Yellow Y 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of ➁, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diode. A3-114 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - LW Series LED and Incandescent Pilot Lights (Sub-Assembled) Removable Terminal* + Operator + Lamp + Lens = Completed Unit A3 * Removable terminals are applicable for PCB terminated types only. Part Numbers: Pilot Light Operators Termination Style Solder PC Board Screw Round † LW1P-00 LW1P-00M LW1P-0 Square † LW2P-00 LW2P-00M LW2P-0 1. † Requires LW-C00V removable terminals in addition to operator. 2. Solder and screw terminals are unibody design (they do not use a removable terminal block). Part Numbers: Lenses Type Part Number Round LW1A-P1-➁ Square LW2A-P1-➁ In place of ➁, specify Lens Color Code. Part Numbers: Lamps (not included in assemblies)➁ LED/Lens Color Code Type Voltage Part Number Color Code 6V AC/DC±10% LSTD-6➁Amber A LED 12V AC/DC±10% LSTD-1➁Green G 24V AC/DC±10% LSTD-2➁Red R 120V AC±10% LSTD-H2➁Blue S 240V AC ±10% LSTD-M4➁White W 6.3V AC/DC IS-6 Incandescent Yellow Y 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of ➁, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diode. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-115 ø22mm - LW Series Oiltight Switches & Pilot Devices Selector and Keylock Switches (Assembled) Part Numbers: LW1S Selector Switches Part Number Style Position Contact Material Contact Solder/Tab PC Board Screw SPDT LW1S-2C1 LW1S-2C1V — Round 90° 2-position A3 Gold DPDT LW1S-2C2 LW1S-2C2V LW1S-2C2M maintained 3PDT LW1S-2C3 LW1S-2C3V — LR SPDT LW1S-2C5 — — Silver DPDT LW1S-2C6 — LW1S-2C6M 3PDT LW1S-2C7 — — 45° 3-position DPDT LW1S-3C2 LW1S-3C2V LW1S-3C2M Gold maintained 3PDT LW1S-3C3 LW1S-3C3V — C DPDT LW1S-3C6 — LW1S-3C6M LR Silver 3PDT LW1S-3C7 — — 1. Knob color: Black; Directional Indication Color: White 2. For contact operation, see next page. 3. For sub-assembly part numbers, see page A3-118. Part Numbers: LW1K Keylock Selector Switches Part Number Style Position Contact Material Contact Solder/Tab PC Board Screw SPDT LW1K-2C1A LW1K-2C1VA — Round 90° 2-position Gold DPDT LW1K-2C2A LW1K-2C2VA LW1K-2C2MA maintained 3PDT LW1K-2C3A LW1K-2C3VA — LR SPDT LW1K-2C5A — — Silver DPDT LW1K-2C6A — LW1K-2C6MA 3PDT LW1K-2C7A — — 45° 3-position DPDT LW1K-3C2A LW1K-3C2VA LW1K-3C2MA Gold maintained 3PDT LW1K-3C3A LW1K-3C3VA — C DPDT LW1K-3C6A — LW1K-3C6MA LR Silver 3PDT LW1K-3C7A — — 1. Every key selector uses an identical key. 2. The key is removable in all positions. 3. If a different configuration is required, contact an IDEC representative for more information. 4. For contact operation, see next page. 5. For sub-assembly part numbers, see page A3-118. Part Numbers: LW1F LED and Incandescent Illuminated Selector Switches Part Numbers Style Position Contact Material Contact Solder/Tab PC Board Screw Round SPDT LW1F-2C10-➁LW1F-2C10V-➁— 90° 2-position Gold DPDT LW1F-2C20-➁LW1F-2C20V-➁LW1F-2C20M-➁ maintained 3PDT LW1F-2C30-➁LW1F-2C30V-➁— LR SPDT LW1F-2C50-➁—— Silver DPDT LW1F-2C60-➁— LW1F-2C60M-➁ 3PDT LW1F-2C70-➁—— 45° 3-position DPDT LW1F-3C20-➁LW1F-3C20V-➁LW1F-3C20M-➁ Gold maintained 3PDT LW1F-3C30-➁LW1F-3C30V-➁— C LR DPDT LW1F-3C60-➁— LW1F-3C60M-➁ Silver 3PDT LW1F-3C70-➁—— 1. In place of ➁, specify color code. See previous page for color codes. 2. Lamps must be ordered separately for all illuminated pushbuttons. See previous page. 3. For contact operation, see next page. 4. For sub-assembly part numbers, see page A3-118. A3-116 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - LW Series Contact Operations Contact Operation: Selector and Keylock Switches Operator Position and Contact Position (Top View) Position Contact Left Center Right A3 NO NC NO NC SPDT _ C C Left Right Left Right LR NO NC NO NC NO NC NO NC DPDT _ 90° 2-Position C C C C Maintained Left Center Right Left Center Right NO NC NO NC NO NC NO NC NO NC NO NC 3PDT _ C C C C C C Left Right Left Right Left Right NO NC NO NC NO NC NO NC NO NC NO NC DPDT C LR C C C C C C 45° Left Center Right Left Center Right Left Center Right NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC 3-Position Maintained 3PDT C C C C C C C C C Terminal Arrangements (Bottom View): LW❏L and LW❏B Pushbuttons 3 pole illuminated 2 pole illuminated 3 pole non-illuminated Lamp Lamp Terminal Terminal (+) (+) Lamp Terminal (—) Lamp Terminal (—) SPDT has C, NO and NC only on the SPDT has C, NO and NC only on the center. DPDT has C, NO, and NC only right. DPDT has C, NO, and NC only on the right and left. on the right and center. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-117 X2 X2 X1 C NO NC C NO NC C NO NC X2 X1 C NO NC C NO NC C NO NC C NO NC C NO NC ø22mm - LW Series Oiltight Switches & Pilot Devices Selectors and Key Switches (Sub-Assembled) Contact Block + Operator + Lens* = Completed Unit A3 *Lens for illuminated units only Part Numbers: Operators Unit Position Part Number Part Numbers: Knob (Lens) Non-Illuminated 2-position LW1S-2Y Selector Switch Style Part Number 3-position LW1S-3Y Illuminated Selector Switches Key Switch 2-position LW1K-2A LW1A-F-➁ 3-position LW1K-3A Illuminated 2-position LW1F-20* Selector Switch In place of ➁, specify LED/Lens Color Code from table below. 3-position LW1F-30* * Lens must be purchased separately for illuminated units. Part Numbers: Contact Blocks Part Number Appearance Style Contact Material Contact Solder/Tab PC Board Screw SPDT LW-C10 LW-C10V — Gold DPDT LW-C20 LW-C20V LW-C20M 3PDT LW-C30 LW-C30V — Illuminated Selector Switches SPDT LW-C50 — — Silver DPDT LW-C60 — LW-C60M 3PDT LW-C70 — — SPDT LW-C1 LW-C1V — Gold DPDT LW-C2 LW-C2V LW-C2M 3PDT LW-C3 LW-C3V — Non-Illuminated Selector Switches SPDT LW-C5 — — Silver DPDT LW-C6 — LW-C6M 3PDT LW-C7 — — Part Numbers: Lamps (not included in assemblies)➁ LED/Lens Color Code Type Voltage Part Number Color Code 6V AC/DC±10% LSTD-6➁ Amber A LED 12V AC/DC±10% LSTD-1➁ Green G 24V AC/DC±10% LSTD-2➁ Red R 120V AC±10% LSTD-H2➁ Blue S 240V AC ±10% LSTD-M4➁ White W 6.3V AC/DC IS-6 Incandescent Yellow Y 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of ➁, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diode. A3-118 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - LW Series Accessories — LW Series Style Description/Usage Part Number Ring Wrench (optional) 1. Metallic tool used for tightening the plastic locking ring when install- A3 ing the LW series on a panel. LW9Z-T1 2. Tightening torque should not exceed 1.2N-m (12 kgf-cm) when tightening a locking ring. Lamp Holder Tool (optional) Rubber tool used for replacing incandescent or LED lamps installed in illuminated switches and pilot lights and pilot lights ø0.546" ø0.452" OR-55 (ø14mm) (ø11.6mm) 2.301" (59mm) Terminal Cover Nylon cover for pushbuttons and selectors with solder terminals snaps (for solder tab terminal) onto contact block. LW-VL2 (Insert the lead wires through terminal cover holes before wiring.) Terminal Cover Nylon cover for pushbuttons and selectors for screw terminals snaps (for screw terminal) onto contact block. LW-VL2M (Insert the lead wires through terminal cover holes before wiring.) Terminal Cover (for unibody pilot light with solder tab terminal) Nylon cover for unibody pilot lights with solder terminals. LW-PVL Terminal Cover (for unibody pilot light with screw terminal) Nylon cover for unibody pilot lights with screw terminals. LW-PVLM Black rubber plug Ţlls unused 22mm panel cutouts. Rubber Mounting Hole Plug 0.137" (3.5mm) ø1.131" (ø29mm) OB-31 0.137" ø0.975" (ø25mm) (3.5mm) 1. Used for plugging unnecessary mounting holes in the panel. Tighten Metallic Mounting the attached locking ring to a torque of 1.2N-m (12kgf-cm) maximum Hole Plug 2. Degree of Protection: IP66 ø1.0" (ø25.8mm) LW9Z-BM 0.468" (12mm) 0.117" (3mm) Locking Ring LW9Z-P1-W (round) Replacement White plastic engraving plate for use on all illuminated units (included in each lens). Marking Plates LW9Z-P2-W (square) May be used to capture printed mylar insert (not supplied by IDEC) under lens face. ALW3B (mushroom) Anti-Rotation Ring Prevents rotation of switches in panel. LW9Z-L (included with all selector and key switches only) Replacement Keys One pair of keys. (#231) KG9Z-SK Replacement Use to secure operator to panel. Locking Ring LW9Z-LN (included with all assembled switches and operators) For replacement lamps, see previous page. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-119 LOCK TP O LOCK TP O LOCK LOCK LOCK LOCK LOCK LOCK ø22mm - LW Series Oiltight Switches & Pilot Devices Dimensions: Pushbuttons LW❏L & LW❏B: Illuminated & Non-Illuminated Pushbuttons Gasket M3 Screw Terminal Terminal Cover Panel Thickness: 0.8 to 6 mm LW-VL2 Locking Ring Terminal Cover Extended LW-VL2M A3 9 12.6 54.9 47 Mushroom 9 17 25 25 25.4 26.5 Screw Terminal PC Board Terminal Solder/Tab Terminal PC Board Terminal Solder/Tab Terminal Round Width 2.8 × 0.5t Width 0.8 × 0.5t Round Square w/Square Bezel 1.0 2.6 2-R0.6 8.5 11.7 2.6 25.8 25.8 53.5 5.4 36 936 9 ∗ Screw Terminal PC Board Terminal Solder/Tab Terminal Terminal Cover Gasket M3 Screw terminal Panel Thickness: 0.8 to 6 mm LW-VL2 Locking Ring Extended Terminal Cover LW-VL2M 9 12.6 54.9 47 Mushroom 9 17 25.4 25 25 26.5 Screw Terminal PC Board Terminal Solder/Tab Terminal PC Board Terminal Tab Terminal (solder) Round 1.0 2.6 0.8 × 0.5t Width 2.8 × 0.5t Round Square w/Square Bezel 2-R0.6 8.5 11.7 25.8 25.8 53.5 936 9 5.4 36 ∗ Screw Terminal PC Board Terminal Solder/Tab Terminal A3-120 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC ø 25.8 ø25.8 ø30 ø 30 R18 R18 R18 R18 R18 R18 Switches & Pilot Devices 8.2 6.2 23.2 2.0 23.2 8.2 2.0 6.2 5 5 5 5 6.8 6.8 1.2 1.2 16.2 16.2 4.85 X2 X1 X2 X2 X2 X1 6.8 6.8 C NO NC C NO NC 4.85 6.5 C NO NC C NO NC 6 6 6.8 6.8 6 6 18.2 1.2 1.2 4.85 18.2 16.2 16.2 6.8 6.8 4.85 6.5 1.2 1.2 Switches & Pilot Devices LOCK TP O T O P O P Oiltight Switches & Pilot Devices ø22mm - LW Series Dimensions: Pilot Lights LW1P/LW2P Pilot Lights Gasket Panel Thickness: 0.8 to 6 mm Terminal Cover M3 Screw terminal Panel Thickness: 0.8 to 6 mm Locking Ring Locking Ring LW-PVL Terminal Cover LW-PVLM A3 Gasket ∗ 36 36 Round Tab Terminal (solder) PC Board Terminal (solder) 7.2 Round Square w/Square Bezel Width 2.8 × 0.5t 0.8 × 0.5t 19 2 8.5 11.7 25.8 25.8 ∗ 7.7 26.8 7.5 27 9 5.5 9 36 Screw Terminal Solder/Tab Terminal PC Board Terminal 1.0 2.6 2-R0.6 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-121 ø25.8 4.5 6.0 5.95 6.75 1.2 5 5 1.2 11.35 LOCK LOCK TOP TP O LOCK LOCK LOCK ø22mm - LW Series Oiltight Switches & Pilot Devices Dimensions: Selector and Keylock Switches LW1S and LW1K Selector and Keylock Switches Terminal Cover Gasket Panel Thickness: 0.8 to 6 mm Locking Ring LW-VL2 M3 Screw Terminal Terminal Cover LW-VL2M A3 Anti-Rotation Ring 54.9 47 2.6 PC Board Terminal Tab Terminal (solder) Round Round Width 0.8 × 0.5t Width 2.8 × 0.5t w/Square Bezel 2 8.5 11.7 9 25.8 ∗ 5.4 36 9 53.5 36 17.5 Screw Terminal PC Board Terminal Solder/Tab Terminal Terminal Cover Gasket Panel Thickness 0.8 to 6 mm Locking Ring LW-VL2 Anti-Rotation Ring 0.5 47 2.6 Tab Terminal (solder) Round Round Width 2.8 × 0.5t w/Square Bezel 8.5 11.7 10.5 25.8 ∗ 9 36 37 Solder/Tab Terminal 1.0 2.6 25.4 25 2-R0.6 Screw Terminal PC Board Terminal 25 26.2 Solder/Tab Terminal A3-122 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC ø25.8 ø 25.8 R18 R18 R18 Switches & Pilot Devices 23.2 8.2 2.0 6.2 18.2 16.2 16.2 X2 X2 X1 C NO NC 6.8 6.8 5 5 C NO NC 4.85 1.2 6.8 6.8 6.8 6.8 6 6 66 4.85 4.85 1.2 1.2 1.2 Switches & Pilot Devices LOCK TOP LOCK LOCK LOCK Oiltight Switches & Pilot Devices ø22mm - LW Series Dimensions: Selector and Keylock Switches, continued and Layouts LW1F LED and Incandescent Illuminated Selector Switches Terminal Cover Gasket Panel Thickness: 0.8 to 6 mm Round LW-VL2 Locking Ring M3 Screw Terminal w/Square Bezel Round A3 Terminal Cover LW-VL2M Anti-Rotation 0.5 25.8 Ring 54.9 47 PC Board Terminal (solder) Tab Terminal (solder) 0.8 × 0.5t Width 2.8 × 0.5t 2.6 11.7 9 8.5 25.4 25 25 53.5 9 36 17.5 5.4 36 26.2 PC Board Terminal Solder/Tab Terminal PC Board Terminal Solder/Tab Terminal Screw Terminal Screw Terminal 1.0 2.6 2-R0.6 Layouts LW❏L PC Board Drilling Layout LW❏B PC Board Drilling Layout PC Board Terminal PC Board Terminal Bottom View Bottom View Pilot Lights 0.265" 0.265" PC Board Drilling Layout (6.8mm) (6.8mm) PC Board Terminal 0.265" (6.8mm) 0.265" (6.8mm) 0.189" (4.85mm) 0.189" (4.85mm) 0.195" 0.195" Bottom View (5mm) (5mm) 0.254" (6.5mm) 0.047" (1.2mm) 0.443" (11.35mm) 0.195" 0.195" 0.195" (5mm) (5mm) (5mm) 0.195" 0.047" 0.047" (5mm) ø0.047" (ø1.2mm) holes ø0.047" (ø1.2mm) holes (1.2mm) (1.2mm) ø0.047" (ø1.2mm) holes Mounting Hole Layout 1. When determining mounting centerlines, allow for easy operation. +0.02" 2. Mushroom (Ø 1.17" (Ø 30mm)) = 1.248" (32mm) ø0.87" - 0 Tab terminal = 1.014" (26mm) (with/without terminal cover) +0.16" (ø22.3 mm) 0 PC board terminal = 1.014" (26mm) Screw terminal = 1.56" (40mm) 3. Mushroom (Ø 1.17" (Ø 30mm) = 1.248" (32mm) Tab terminal = 1.053" (27mm) (with terminal cover) Tab terminal = 1.014" (26mm) (without terminal cover) PC board terminal = 1.014" (26mm) Screw terminal = 1.014" (26mm) 1.014" (26mm) Note 3 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-123 ø25.8 R18 R18 R18 1.014" (26mm) Note 2 8.2 6.8 6.8 5 5 4.85 6.5 1.2 6.8 6.8 6 6 4.85 6.5 1.2 1.2 23.2 16.2 X2 X2 X1 C NO NC C NO NC 18.2 16.2 ø22mm - LW Series Oiltight Switches & Pilot Devices Instructions — LW Series the same direction. Then push the lamp lightly and turn it clockwise. Replacement of Lens & Marking Plate Grooves in the Removing Operator Unit 1. Remove the operator (lens, marking plate, and lens holder) by inserting a A3 screwdriver into the recess of the lens through the bezel. Replacement of Lamps by Removing the Contact Block The lamp can be replaced by removing the contact block without using the lamp holder tool. Marking Plates & Films For LW series illuminated pushbuttons and pilot lights, legends and symbols can be engraved on marking plates, or printed mylar can be inserted under the 2. Remove the marking plate by pushing the lens from the rear to disengage lens for labelling purposes. the latches between the lens and the lens holder, using the screwdriver as shown below. Marking Plate and Marking Film Size Lens Style Round Lens Square Lens Engraving Engraving Area Area Built-in ø0.694" (ø17.8mm) Marking ø0.683" (ø17.5mm) 0.033" 0.033" The translucent filter in the lens holder can Plate (0.85mm) (0.85mm) not be removed because this filter is sealed to make the unit waterproof and oiltight. Engraving must be made on the engraving area within 0.02" (0.5mm) deep. Installing The marking plate is made of white acrylic resin. For round lens types, place the marking plate on the lens holder with the anti- rotation projection engaged and press the lens onto the lens holder to engage the latches. For square lens types, insert the marking plate into the lens, and press the lens onto the lens holder to engage the latches. Pay attention to the orientation of the marking plate. Pay attention to the orientation of the marking plate. Applicable Marking 0.69" (17.7mm) Film For Round Lens For Square Lens Mylar for printing labels are not included and must be provided and printed by user. Two 0.004" (0.1mm)-thick Ţlms or one 0.008" (0.2mm)-thick Ţlm can be installed in the lens. Recommended marking Ţlm: Mylar Insertion Order of Marking Plate & Film Lens Marking Plate Lens Holder Lens Marking Plate Lens Holder Top Marking Side For Round Lens Replacement of Lamps Lamps can be replaced using the lamp holder tool (OR-55) from the front of the panel. Also by removing the contact block from the operator unit, the lamp can be replaced. Replacement of Lamps from the Front of the Panel. (How to Remove) Lens Film Marking Plate Lens Holder Housing 1. Push and turn the lamp counterclockwise using the side A of the lamp holder tool, and the lamp and the lamp holder can be removed. Insertion Order of Marking Plate & Film. Top Marking Side For Square Lens (How to Install) Lens Film Marking Plate Lens Holder Housing 1. Insert the lamp into the lamp holder tool and hold the lamp as in the 1. Mylar is not included. following illustration. 2. Pay attention to the orientation of marking plate. Lamp Lamp Holder Tool 2. Place the insertion guide of the lamp and the groove in the operator unit in A3-124 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices 0.772" (19.8mm) 0.772" (19.8mm) Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - LW Series Instructions con’t Panel Mounting Connection Remove the contact block from the operator. Insert the operator into the panel Positive-lock connector and easy-lock connector are applicable to cut-out from the front, then install the contact block to the operator. tab terminals. Removing the Contact Block A3 Turn the locking lever on the contact block in the direction opposite to the Single Board Mounting arrow on the housing. Then the contact block can be removed. Installing the Contact Block Mounting the switches and pilot lights on one PC board offers the following Insert the contact block, with the TOP markings on the contact block and the features. operator placed in the same direction. Then lock the units, turning the locking 1. Reduced installation labor, easy wiring, space saving, and standardization. lever in the direction of the arrow. 2. Since the contact blocks on the PC board can be removed easily using a locking lever, the LW series switches and pilot lights are easy to maintain. 3. Because the LW series switches and pilot lights require no studs for fasten- ing the control unit to a PC board, special preparation of operation panel is not needed. For details on one board mounting, contact IDEC. Notes on Mounting Use the optional Ring Wrench (LW9Z-T1) to mount the operator onto a panel. Tightening torque should not exceed 1.2N-m (12 kgf-cm). Do not use pliers. Excessive tightening will damage the locking ring. Wiring 1. Solder the terminals within 20W/5 seconds or 260°C/3 seconds without exerting external force to the terminals. While soldering, do not touch the soldering iron to the housing. While wiring, prevent tension from being applied to the terminals. Do not bend or raise the terminals, nor exert excessive force Light Touch And High Reliability to terminals. 2. Use a non-corrosive resin liquid ţux. Collective Mounting As the locking lever can be turned easily from the rear of the units using a 0.117" screwdriver, the contact blocks can be removed even when Stroke (3mm) mounted collectively. Operating-force Snap Switching Mechanism Notes for Terminal Cover 2000 TW series pushbutton (Solder/Tab Terminal) (SPST-NO/SPST-NC) Insert the terminal cover into the contact block with the TOP markings on the contact block and the terminal cover in the same direction. 1500 When wiring, insert the lead wires into the terminal cover holes before wiring. Load (g) 1000 LW series pushbutton (Momentary DPDT) 500 LW series pushbutton (Momentary SPDT) Notes for Wiring 0 0.039"0.078"0.117"0.156"0.195"0.234" (1mm) (2mm) (3mm) (4mm) (5mm) (6mm) When installing a terminal cover onto the solder/tab terminal contact block, solder the inside of lamp terminal (toward the switch terminals) and wire. Stroke (Screw Terminal Type) Install a terminal cover to the control unit before wiring. 1. After wiring, terminal covers cannot be installed. 2. When terminal covers are used, round crimping terminals cannot be used. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-125 ø22mm - TW Series Oiltight Switches & Pilot Devices TW Series — 22mm NEMA Style Pushbuttons A3 TW NEMA Style Switches with snap-on contacts Key features include: IDEC has your 22mm switching needs covered. Button styles include ţush, extended, mushroom, or square and all • Corrosion resistant octagonal chrome plated locking bodies are crafted from fracture-resistant nylon. bezel • Snap-on 10A contact blocks All illuminated units feature two lense styles, one that maximizes light •Transformer or full voltage dispersion, the other accommodates direct lense engraving. • Incandescent or LED illumination • Slow make, double break, self cleaning contacts Self cleaning contact mechanisms allow for a wide current rating, 5mA •Modular construction for maximum ţexibility to 10A, which reduces the need for various contact materials. •NEMA 4X and IP65 watertight/oiltight panel •Available assembled or as sub-components When looking for a 22mm switch that is durable, easy to use, and ver- •Large M3.5 screw terminals with captive sems plate satile, then IDEC's TW series is your solution. File No. DK95-01696 CSA CertiŢed File No. 9561116E01 CertiŢcate No. UL Listed File No.LR48366 2030010305027380 File No. E70646 A3-126 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Conforming to Standards EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14 Approvals CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer Certificate No. (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) File No. E68961 File No. LR21451 2030010305027380 UL: pushbuttons and selector switches: A600 A3 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) TÜV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer Registration No: J9551802 (E-Stops) (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) Registration No: J9551803 (All other switches) Registration No: J9551804 (Pilot Lights) Operation: –25 to +50°C (without freezing) Operating Temperature Storage: –40 to +80°C (without freezing) 2 Vibration Resistance 5 to 55Hz, 100m/sec (10g) conforming to IEC6068-2-6 2 Shock Resistance 1000m/sec (100g) conforming to IEC6068-2-7 Electric Shock Protection Class 0 conforming to IEC60536 Degree of Protection IP65 from front of the panel; (IP54 for key switches) (conforming to IEC60529) IP20 (Type HW-F contact block) NEMA 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (NEMA 1, 2, 3R, 5, 12, 13 for key switches) (conforming to NEMA ICS6-110) Momentary pushbuttons: 5,000,000 (900 operations per hour) Mechanical Life All other switches: 500,000 3 for switches not using a transformer Pollution Degree (conforming to IEC60947-1) 2 for switches using a transformer AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB) DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC) Rated Operational Characteristics DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB) Rated Insulation Voltage 600V Rated Switching Over-Voltage Less than 4kV, conforming to IEC60947-1 4kV for contact circuit Rated Impulse Withstanding Voltage 2.5kV for lamp circuit Rated Thermal Current 10 Amp Minimum Switching Capacity 5 mA at 3V AC/DC Contact Operation Slow break NC or slow make NO, self-cleaning Recommended Terminal Torque 0.8 N m (7.1 in lb.) External Short-Circuit Protection 10A 250V fuse conforming to IEC60269-1 Applicable Wire Size Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG Contact Resistance Initial contact resistance of 50mΩ or less 4mm (NO and NC) Contact Gap 2mm (NO-EM and NC-LB) Electrical Reliability MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA) Incandescent: 1 W Lamp Ratings LEDs: 6V: 17mA max, 12/24V: 11mA max, 120/240V: 10mA max Horsepower Rating 1/4 HP @ 120V (single-phase, non-reversing motor); 1 HP @ 240V (3 phase, non-reversing motor) Maximum Inrush Current 40 A (40 ms) Contact Material Silver Contact Block Type HW-C/HW-F Pushbuttons Rated Insulation Voltage 600V Illuminated Pushbuttons Selector Switches Rated Continuous Current 10A Illuminated Selector Switches Pushbutton Selectors Contact Ratings by Utilization Category AC-15 (A600) IEC 60947-5-1 DC-13 (P600) Contact Ratings by Utilization Category Operational Voltage 24V 48V 50V 110V 220V 440V AC AC-12 Control of resistive loads & solid state loads 10A — 10A 10A 6A 2A 50/60 AC-15 Control of electromagnetic loads (> 72VA) 10A — 7A 5A 3A 1A Hz Operational Current DC-12 Control of resistive loads & solid state loads 8A 5A — 2.2A 1.1A — DC DC-13 Control of electromagnets 5A 2A — 1.1A 0.6A — www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-127 Characteristics Contact Ratings Specifications ø22mm - TW Series Oiltight Switches & Pilot Devices Non-Illuminated Pushbuttons (Assembled) A3 Assembled Pushbuttons AB()W110 ( ) - B Function Button Color B: Momentary B: Black G: Green W: White O: Maintained R: Red S: Blue Y: Yellow K: Key On/Off Lock Terminal Style Bezel Shape Blank: Standard Blank: Octagonal N: Fingersafe (IP20) F: Full Shroud G: Mushroom Shroud Contact Arrangement Q: Square 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO-1NC 22: 2NO-2NC Button Shape 1: Flush 2: Extended 3: Mushroom Head Ø 29mm 4: Mushroom Head Ø 40mm Series Designation W:TW Series To be used for interpreting part numbers only, not for part number development. A3-128 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Non-Illuminated Pushbuttons (Assembled) con’t Part Numbers: Non-illuminated Pushbuttons① Button Color Code Style Contacts Momentary Action Maintained Action Color Code Black B 1NO ABW110-➀AOW110-➀ 1NC ABW101-➀AOW101-➀ Green G Flush 1NO-1NC ABW111-➀AOW111-➀A3 2NO ABW120-➀AOW120-➀ Red R 2NC ABW102-➀AOW102-➀ Blue S 1NO ABW210-➀AOW210-➀White W 1NC ABW201-➀AOW201-➀ Extended 1NO-1NC ABW211-➀AOW211-➀Yellow Y 2NO ABW220-➀AOW220-➀ 2NC ABW202-➀AOW202-➀ 1NO ABFW110-➀AOFW110-➀ 1NC ABFW101-➀AOFW101-➀ Recessed 1NO-1NC ABFW111-➀AOFW111-➀ 2NO ABFW120-➀AOFW120-➀ 2NC ABFW102-➀AOFW102-➀ 1NO ABFW210-➀AOFW210-➀ 1NC ABFW201-➀AOFW201-➀ Extended with Full Shroud 1NO-1NC ABFW211-➀AOFW211-➀ 2NO ABFW220-➀AOFW220-➀ 2NC ABFW202-➀ AOFW202-➀ 1NO ABW310-➀AOW310-➀ 1NC ABW301-➀AOW301-➀ Ş 29mm Mushroom Head 1NO-1NC ABW311-➀AOW311-➀ 2NO ABW320-➀AOW320-➀ 2NC ABW302-➀ AOW302-➀ 1NO ABW410-➀ AOW410-➀ 1NC ABW401-➀ AOW401-➀ Ş 40mm Mushroom Head 1NO-1NC ABW411-➀ AOW411-➀ 2NO ABW420-➀ AOW420-➀ 2NC ABW402-➀ AOW402-➀ 1NO ABGW410-➀AOGW410-➀ 1NC ABGW401-➀AOGW401-➀ Ş 40mm Mushroom Head 1NO-1NC ABGW411-➀AOGW411-➀ with Full Shroud 2NO ABGW420-➀AOGW420-➀ 2NC ABGW402-➀ AOGW402-➀ 1NO ABQW110-➀AOQW110-➀ 1NC ABQW101-➀AOQW101-➀ Square Flush 1NO-1NC ABQW111-➀AOQW111-➀ 2NO ABQW120-➀AOQW120-➀ 2NC ABQW102-➀ AOQW102-➀ 1NO ABQW210-➀AOQW210-➀ 1NC ABQW201-➀AOQW201-➀ Square Extended 1NO-1NC ABQW211-➀ AOQW211-➀ 2NO ABQW220-➀ AOQW220-➀ 2NC ABQW202-➀ AOQW202-➀ 1NO AKW210 1NC AKW201 Keylock Push On/Off 1NO-1NC AKW211 – 2NO AKW220 2NC AKW202 1. In place of ➀, specify the Button Color Code from table. 2. For sub-assembled part numbers, see page A3-130. 3. For accessories, see page A3-156. 4. For dimensions, see page A3-158. 5. Keyed switches are supplied with two keys. All units are keyed alike. For custom keys, contact IDEC. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-129 ø22mm - TW Series Oiltight Switches & Pilot Devices Non-Illuminated Pushbuttons (Sub-Assembled) Contact Blocks + Operator + Button = Complete Part A3 Part Numbers: Operators Part Numbers: Buttons Part Numbers: Contact Blocks Part Number Style Part Number Description Part Number Style Round Flush Momentary Maintained 1NO 1NC Round Flush/Extended Standard Exposed ABW1B-➀Screw HW-C10 HW-C01 ABW-100 AOW-100 HW-C10R HW-C01R Round Extended (early make) (late break) Round with Full Shroud ABW2B-➀ Fingersafe (IP20), CE marked ABFW-200 AOFW-200 HW-F10 HW-F01 Ş 29mm Mushroom HW-F10R HW-F01R (early make) (late break) ABW3B-➀ Ş 40mm, Ş 29mm Mush- room Head Dummy Block ABW-300 AOW-300 Ş 40mm Mushroom TW-DB ABW4B-➀ Ş 40mm Mushroom Head with Full Shroud 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. Square Flush ABGW-400 AOGW-400 2. Use of early and late break contacts creates a make before break function ABQW1B-➀ ① Button Color Code Square Flush/Extended Square Extended Color Code Black B ABQW2B-➀ ABQW-100 AOQW-100 Green G Red R In place of ➀, specify the Blue S Button Color Code from Keylock Push On/Off White W table. Yellow Y AKW-200 A3-130 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series E-Stops (Assembled) A3 Assembled E-Stops AV (L) W 4 (B) (99) 11 (D) (N) - R - (24V) Function Lamp Voltage V: Pushlock Turn Reset (full voltage illuminated units only) Y: Push-Pull 6V: 6V AC/DC X: Pushlock Key Reset 12V: 12V AC/DC 24V: 24V AC/DC 120V: 120V AC (LED only) Illumination 240V: 240V AC (LED only) Blank: None L: Illuminated Button/Lens Color A: Amber R: Red W: White Series Designation G: Green S: Blue Y: Yellow W: TW Series B: Black Button/Lens Size 3: 29mm Mushroom Contact Terminal Style 4: 40mm Mushroom Blank: Standard N: Fingersafe (IP20) Lens Type (illuminated units only) Blank: Standard (ribbed) Lamp Type B: Engravable (smooth with insert) (illuminated units only) Blank: Incandescent D: LED Illuminated Circuit (illuminated unit only) 99: Full Voltage (lamp determines voltage) 126:120V AC Step Down Transformer Contact Arrangement 246: 240V AC Step Down Transformer 10: 1NO 01: 1NC 486: 480V AC Step Down Transformer 20: 2NO 02: 2NC 11: 1NO/1NC 22: 2NO/2NC Use only for interpreting part numbers. Do not use for developing part numbers. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-131 ø22mm - TW Series Oiltight Switches & Pilot Devices E-Stops (Assembled) con’t Part Numbers: Non-Illuminated E-Stops Part Numbers: Illuminated E-Stops Style Contacts Part Number Style Type Contacts Part Number Ş 40mm Pushlock Turn Reset* AVLW4 ➃ 11⑤-R* 1NO-1NC Ş 40mm Pushlock Turn Reset Type 1NO AVW410-R* Transformer 2NO AVLW4 ➃ 20⑤-R* A3 1NC AVW401-R* 2NC AVLW4 ➃ 02⑤-R* 1NO-1NC AVW411-R* 1NO-1NC AVLW49911➄-R*-➂ 2NO AVW420-R* Full 2NO AVLW49920➄-R*-➂ 2NC AVW402-R* Voltage 2NC AVLW49902➄-R*-➂ 1NO-1NC AVLW3➃11➄-R* Ş 29mm Pushlock Turn Reset Ş 29mm Pushlock Turn Reset* Transformer 2NO AVLW3➃20➄-R* 1NO AVW310-R* 2NC AVLW3➃02➄-R* 1NC AVW301-R* 1NO-1NC AVLW39911➄-R*-➂1NO-1NC AVW311-R* Full 2NO AVLW39920➄-R*-➂2NO AVW320-R* Voltage 2NC AVLW39902➄-R*-➂2NC AVW302-R* AYLW4 ➃ 11➄-➁1NO-1NC Ş 40mm Push-Pull Transformer 2NO AYLW4 ➃ 20➄-➁Ş 40mm Push-Pull 2NC AYLW4 ➃ 02➄-➁ 1NO AYW410-➀ 1NC AYW401-➀1NO-1NC AYLW49911➄-➁-➂ Full 1NO-1NC AYW411-➀2NO AYLW49920➄-➁-➂ Voltage 2NO AYW420-➀2NC AYLW49902➄-➁-➂ 2NC AYW402-➀ 1. *Available in red only. 2. In place of ➁, specify the Lens Color Code (see table above). Ş 40mm Pushlock Key Reset * 3. In place of ➂, specify the Full Voltage Code (lamp voltage) 1NO AXW410- R* (see table above). 1NC AXW401- R* 4. In place of ➃, specify the Transformer Voltage Code (see 1NO-1NC AXW411- R* 2NO AXW420- R* table above). 2NC AXW402- R* 5. In place of ⑤, specify the Lamp Type Code from table above. 6. For sub-assembly part numbers, see page A3-134. 7. For accessories, see page A3-156. 1. *Available in Red only. 8. For dimensions, see page A3-158. 2. In place of ➀, specify the Button Color Code from table. 3. For sub-assembled part numbers, see page A3-130. 4. For accessories, see page A3-156. 5. For dimensions, see page A3-158. ① Button Color Code ➂ Full Voltage Code➁ LED/Lens Color Code Color Code Voltage Code Color Code 6V AC/DC 6V Black B Amber A 12V AC/DC 12V Green G Green G 24V AC/DC 24V Red R Red R 120V AC 120V (LED only) Blue S Blue S 240V AC 240V (LED only) White W White W Yellow Y ➄ Lamp Type Code ➃ Transformer Voltage Codes Lamp Code Voltage Code Incandescent Blank 120VAC 126 LED D 240VAC 246 480VAC 486 Transformers step down to 6V. A3-132 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series E-Stops (Sub-Assembled) Transformer/ + Contacts + Lamp Holder + Operator + Lamp + Button or Lens = Complete Part Adaptor* A3 * Not applicable for full voltage units Part Numbers: Operators Part Numbers: Buttons Style Part Number Style Part Number Non-illuminated Illuminated Ş 40mm Pushlock Turn Reset Ş 29/Ş 40mm Pushlock Turn Reset AVW4B-R* AVW-300 AVLW3-0600 Ş 29mm Pushlock Turn Reset Ş 40mm Push-Pull AVW3B-R* AYW-400 AYLW4-0600 Ş 40mm Push-Pull Ş 40mm Pushlock Key Reset AYW4B-➀ AXW-300 — Ş 40mm Pushlock Key Reset AXW4B-R* Part Numbers: Lamps Type Voltage Part Number 6V AC/DC LSTD-6➁ LED 12V AC/DC LSTD-1➁1. *Available in Red only 2. In place of ➀, specify the button color 24V AC/DC LSTD-2➁ code from table below. 120V AC LSTD-H2➁ 240V AC LSTD-M4➁ Incandescent 6V AC/DC IS-6 ① Button Color Code ➁ LED/Lens Color Code 12V AC/DC IS-12 Color Code Color Code 24V AC/DC IS-24 Black B Amber A 1. In place of ➁, specify the LED color code. Green G Green G 2. The LED contains a current-limiting resistor Red R Red R and a protection diode. Blue S Blue S White W White W Yellow Y www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-133 ø22mm - TW Series Oiltight Switches & Pilot Devices Illuminated E-Stops (Sub-Assembled) con’t Part Numbers: Lenses Part Numbers: Transformers/Full Voltage Modules Style Description Part Number Part Number Style 120V AC TW-T126B Standard Engravable Full Size Transformer Standard 240V AC TW-T246B Ş 29mm Head Pushlock Turn Reset A3 480V AC TW-T486B 120V AC TW-F126B AVLW3LU-R* AVLW3BLU-R* Fingersafe 240V AC TW-F246B 480V AC TW-F486B Half Size Transformer 120V AC TW-T126SB Ş 40mm Head Pushlock Turn Reset AVLW4LU-R* AVLW4BLU-R* 240V AC TW-T246SB Full voltage model (use with Standard TW-DA1B even number of contacts) Ş 40mm Head Push Pull Fingersafe TW-DA1FB AYLW4LU-➁AYLW4BLU-➁ Full voltage model (use with odd number of contacts) Standard HW-DA1B 1. In place of ➁, specify the lens color code from table on the bottom right. Fingersafe HW-DA1FB 2. *Available only in red 3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engravable insert. All Transformers step down to 6V (use 6V lamp). Part Numbers: Lamp Circuit Components Style Application Part Number Part Numbers: Contact Blocks Short Lamp Holder Description Part Number Used with a Half-size Transformer TW-LH1 1NO 1NC and one contact block Standard Exposed Screw Used with HW-C10 HW-C01 Full-size Transformer and Long Lamp Holder two contact blocks HW-C10R HW-C01R Used with Half-size Trans- (early make) (late break) former and three contact TW-LH2 blocks Used with Full Voltage Adaptor and two contact Fingersafe (IP20), blocks CE marked Lead Holder HW-F10 HW-F01 Used with TW-LH2 holder when using four contact HW-LH3 HW-F10R HW-F01R blocks (early make) (late break) Dummy Block TW-DB 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function A3-134 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Pilot Lights (Assembled) A3 Assembled Pilot Lights AP (Q) W 1 ( B ) 99 (D) - R - (24V) Function Lamp Voltage P: Pilot Light (Full Voltage Units Only) 6V: 6V AC/DC Bezel Shape 12V: 12V AC/DC Blank: Octagonal (round lenses) 24V: 24V AC/DC Q: Square 120V: 120V AC (LED only) Series Designation 240V: 240V AC (LED only) W: TW Series Lens Color Code Lens Shape A: Amber 1: Flat G: Green 2: Dome R: Red Lens Type S: Blue Blank: Standard (ribbed) W:White B: Engravable (smooth with insert included) Y: Yellow Illumination Circuit Lamp Type 99: Full Voltage (lamp determines voltage) Blank: Incandescent 126:120V AC Step Down Transformer D: LED 246:240V AC Step Down Transformer 486:480V AC Step Down Transformer 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. All transformers step down to 6V. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-135 ø22mm - TW Series Oiltight Switches & Pilot Devices Pilot Lights (Assembled) con’t Part Numbers: Pilot Lights Style Operating Voltage Part Number 120VAC APW1126➃-➁ Round Flat Transformer 240VAC APW1246➃-➁A3 480VAC APW1486➃-➁ Full Voltage — APW199➃-➁-➂ 120VAC APW2126➃-➁Dome Transformer 240VAC APW2246➃-➁ 480VAC APW2486➃-➁ Full Voltage — APW299➃-➁-➂ Square Flat 120VAC APQW1B126➃-➁ Transformer 240VAC APQW1B246➃-➁ 480VAC APQW1B486➃-➁ Full Voltage — APQW1B99➃-➁-➂ 1. In place of ➁, specify the Lens Color Code from table below. 2. In place of ➂ , specify the Full Voltage Code from table below. 3. In place of ➃, specify the Lamp Type Code from table below. 4. For accessories, see page A3-156. 5. For dimensions, see page A3-158. 6. For sub-assembly part numbers, see next page. ➃ Lamp Type Code ➁ Lens Color Code ➂ Full Voltage Code Lamp Code Color Code Voltage Code Amber A 6V AC/DC 6V Incandescent Blank Green G 12V AC/DC 12V LED D Red R 24V AC/DC 24V Blue S 120V AC 120V (LED only) White W 240V AC 240V (LED only) Y Yellow A3-136 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Pilot Lights (Sub-Assembled) Transformer + Operator + Lamp + Lens = Complete Part A3 * Transformer not required for full voltage units. Part Numbers: Operators Part Numbers: Lamps Style Part Number Type Voltage Part Number Round Dome/Flat 6V AC/DC LSTD-6➁ LED 12V AC/DC LSTD-1➁ 24V AC/DC LSTD-2➁APW-199 120V AC LSTD-H2➁ 240V AC LSTD-M4➁ 6V AC/DC IS-6 Incandescent Square 12V AC/DC IS-12 24V AC/DC IS-24 UPQW-199 30V AC/DC IS-30 1. In place of ➁, specify the LED Color Code from table below. 2. The LED contains a current-limiting resistor Same operator is used for full voltage as for trans- and diode bridge. former completed units. Part Numbers: Transformers Style Description Part Number Part Numbers: Lenses 120V AC TW-T126B Part Number Style Standard 240V AC TW-T246B Standard Engravable 480V AC TW-T486B Dome APW2LU-➁— 120V AC TW-F126B Round Flat APW1LU-➁APW1BLU-➁ Fingersafe 240V AC TW-F246B Square Flat — APQW1BLU-➁480V AC TW-F486B All Transformers step down to 6V (use 6V lamp). 1. In place of ➁, specify the Lens Color Code from table below. 2. Standard lenses have a ribbed lens to enhance light dispersion. Marking lenses are smooth and include an engravable insert. ➁ Lens/LED Color Code Color Code Amber A Green G Red R S Blue White W Yellow Y If clear lens is desired, use white mark- ing lens and remove engraving insert www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-137 ø22mm - TW Series Oiltight Switches & Pilot Devices Illuminated Pushbuttons (Assembled) A3 Assembled Illuminated Pushbuttons AL(F)W2 (B) 99 11 (D) (N) - R - (24V) Lamp Voltage (Full Voltage Units Only) Function 6V: 6V AC/DC L: Momentary Action 12V: 12V AC/DC OL: Maintained Action 24V: 24V AC/DC Bezel Shape 120V:120V AC (LED only) Blank: Octagonal (round lenses) 240V: 240V AC (LED only) F: Full Shroud (round lenses) Lens Code Q: Square A: Amber Series Designation G: Green W: TW series R: Red Lens Shape/Size S: Blue 2: Standard Extended (round or square) W: White 3: 29mm Mushroom Y: Yellow 4: 40mm Mushroom Contact Terminal Style Lens Type Blank: Standard Blank: Standard (ribbed) N: Fingersafe B: Engravable (smooth with insert) Lamp Type Illumination Circuit Blank: Incandescent Lamp 99: Full Voltage (lamp determines voltage) D: LED Lamp 126:120V AC Step Down Transformer Contact Arrangement 246:240V AC Step Down Transformer 10: 1NO 01: 1NC 486:480V AC Step Down Transformer 20: 2NO 02: 2NC 11: 1NO-1NC 22:2NO-2NC 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Transformers step down to 6V. A3-138 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Illuminated Pushbuttons (Assembled) Part Numbers: Illuminated Pushbuttons Part Number Style Contacts Momentary Maintained Extended Lens ALW2 ➃ 11⑤-➁AOLW2 ➃ 11⑤-➁1NO-1NC A3 Transformer Type 2NO ALW2 ➃ 20⑤-➁AOLW2 ➃ 20⑤-➁ 2NC ALW2 ➃ 02⑤-➁AOLW2 ➃ 02⑤-➁ ALW29911⑤-➁-➂ AOLW29911⑤-➁-➂ 1NO-1NC Full Voltage 2NO ALW29920⑤-➁-➂ AOLW29920⑤-➁-➂ 2NC ALW29902⑤-➁-➂ AOLW29902⑤-➁-➂ 1NO-1NC ALFW2 ➃ 11⑤-➁AOLFW2 ➃ 11⑤-➁ Extended Lens with Full Shroud Transformer Type 2NO ALFW2 ➃ 20⑤-➁AOLFW2 ➃ 20⑤-➁ 2NC ALFW2 ➃ 02⑤-➁ AOLFW2 ➃ 02⑤-➁ ALFW29911⑤-➁-➂ AOLFW29911⑤-➁-➂ 1NO-1NC Full Voltage 2NO ALFW29920⑤-➁-➂ AOLFW29920⑤-➁-➂ 2NC ALFW29902⑤-➁-➂ AOLFW29902⑤-➁-➂ 1NO-1NC ALW3 ➃ 11⑤-➁AOLW3 ➃11⑤-➁ Ş 29mm Mushroom Lens Transformer Type 2NO ALW3 ➃ 20⑤-➁AOLW3 ➃20⑤-➁ 2NC ALW3 ➃ 02⑤-➁AOLW3 ➃ 02⑤-➁ ALW39911⑤-➁-➂ AOLW39911⑤-➁-➂ 1NO-1NC Full Voltage 2NO ALW39920⑤-➁-➂ AOLW39920⑤-➁-➂ 2NC ALW39902⑤-➁-➂ AOLW39902⑤-➁-➂ Ş 40mm Mushroom Lens 1NO-1NC ALW4 ➃ 11⑤-➁AOLW4 ➃11⑤-➁ Transformer Type 2NO ALW4 ➃ 20⑤-➁AOLW4 ➃20⑤-➁ 2NC ALW4 ➃ 02⑤-➁AOLW4 ➃ 02⑤-➁ ALW49911⑤-➁-➂ AOLW49911⑤-➁-➂ 1NO-1NC Full Voltage 2NO ALW49920⑤-➁-➂ AOLW49920⑤-➁-➂ 2NC ALW49902⑤-➁-➂ AOLW49902⑤-➁-➂ Square Extended 1NO-1NC ALQW2B ➃11⑤-➁AOLQW2B ➃11⑤-➁ Transformer Type 2NO ALQW2B ➃20⑤-➁AOLQW2B ➃20⑤-➁ 2NC ALQW2B ➃02⑤-➁AOLQW2B ➃02⑤-➁ ALQW2B9911⑤-➁-➂ AOLQW2B9911⑤-➁-➂ 1NO-1NC Full Voltage 2NO ALQW2B9920⑤-➁-➂ AOLQW2B9920⑤-➁-➂ 2NC ALQW2B9902⑤-➁-➂ AOLQW2B9902⑤-➁-➂ 1. In place of ➁, specify the Lens Color Code (see table above). Mushroom lenses not available in yellow. 2. In place of ➂, specify the Full Voltage Code (lamp voltage) (see table above). 3. In place of ➃, specify the Transformer Voltage Code (see table above). 4. In place of ⑤, specify the Lamp Type Code from table above. 5. For sub-assembly part numbers, see page A3-140. 6. For accessories, see page A3-156. 7. For dimensions, see page A3-158. ➁ Lens/LED Color Code ➂ Full Voltage Code ➃ Transformer Voltage ⑤ Lamp Type Code Codes Color Code Voltage Code Lamp Code Voltage Code Amber A 6V AC/DC 6V Incandescent Blank 120VAC 126 Green G 12V AC/DC 12V LED D 240VAC 246 Red R 24V AC/DC 24V 480VAC 486 Blue S 120V AC 120V (LED only) Transformers step down White W 240V AC 240V (LED only) to 6V (use 6V lamp). Yellow Y Mushroom lenses not available in yellow. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-139 ø22mm - TW Series Oiltight Switches & Pilot Devices Illuminated Pushbuttons (Sub-Assembled) Transformer/ + Contacts + Lamp Holder + Operator + Lamp + Lens = Complete Part Adaptor* A3 * Not applicable for full voltage units Part Numbers: Operators Part Numbers: Lamps Part Number Type Voltage Part Number Style Momentary Maintained 6V AC/DC LSTD-6➁ LED 12V AC/DC LSTD-1➁Extended ALW-0600 AOLW-0600 24V AC/DC LSTD-2➁Extended with Full Shroud ALFW-0600 AOLFW-0600 120V AC LSTD-H2➁ş29mm/ş40mm Mushroom ALW3-0600 AOLW3-0600 240V AC LSTD-M4➁Square/Extended ALQW-2B0600 AOLQW-2B0600 Incandescent 6V AC/DC IS-6 Part Numbers: Lenses 12V AC/DC IS-12 Part Number Style 24V AC/DC IS-24 Standard Engravable Round Extended 1. In place of ➁, specify the LED Color Code. 2. The LED contains a current-limiting resistor ALW2LU-➁ALW2BLU-➁ and a protection diode. Part Numbers: Lamp Circuit Components Ş 29mm Mushroom Head* Style Application Part Number Short Lamp Holder ALW3LU-➁ALW3BLU-➁ Used with a Half-size Transformer TW-LH1 and one contact block Ş 40mm Mushroom Head* Used with Full-size Transformer and Long Lamp Holder ALW4LU-➁ALW4BLU-➁two contact blocks Used with Half-size Trans- former and three contact TW-LH2 blocks Used with Full Voltage Square Extended Adaptor and two contact blocks — ALQW2BLU-➁ Lead Holder Used with TW-LH2 holder when using four contact HW-LH3 blocks 1. In place of ➁, specify the lens color code from table on the bottom right. 2. * Mushroom lens not available in yellow. ➁ LED/Lens Color Code 3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engravable insert. Color Code Amber A Green G Red R S Blue White W Y Yellow A3-140 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Illuminated Pushbuttons (Sub-Assembled) con’t Part Numbers: Contact Blocks Description Part Number 1NO 1NC Standard Exposed Screw A3 HW-C10 HW-C01 HW-C10R HW-C01R (early make) (late break) Fingersafe (IP20) HW-F10 HW-F01 HW-F10R HW-F01R (early make) (late break) Dummy Block TW-DB 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function. Part Numbers: Transformers/Full Voltage Modules Style Description Part Number 120V AC TW-T126B Full Size Transformer Standard 240V AC TW-T246B 480V AC TW-T486B 120V AC TW-F126B Fingersafe 240V AC TW-F246B 480V AC TW-F486B Half Size Transformer 120V AC TW-T126SB 240V AC TW-T246SB Full voltage model (use with Standard TW-DA1B even number of contacts) Fingersafe TW-DA1FB Full voltage model (use with odd number of contacts) Standard HW-DA1B Fingersafe HW-DA1FB All Transformers step down to 6V (use 6V lamp). www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-141 ø22mm - TW Series Oiltight Switches & Pilot Devices Non-Illuminated Selector Switches (Assembled) A3 Assembled Selector Switches AS W3 (1) (L) 20 (N) - 304 Function Circuit Number (Standard circuits shown on following pages and S: Selector Switch A3-150.) Series Designation Contacts Terminal Style W: TW Series Blank: standard Number of Positions N: Fingersafe (IP20) 2: 2-Position Contact Arrangement Code 3: 3-Position 10: 1NO 01: 1NC 4: 4-Position 20: 2NO 02: 2NC 5: 5-Position 40: 4NO 04: 4NC Spring Return Action 11: 1NO-1NC 22: 2NO-2NC Blank: Maintained Operator Style Code 1: Spring return from Right (2 or 3 position) Blank: Knob Operator 2: Spring return from Left (2 or 3 position) L: Lever Operator 3: 2-Way spring return from Left and Right K: Key Operator (3 position only) 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Custom contact configurations available, contact IDEC for details. 3. Portions of part number inside ( ) are optional. A3-142 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Non-Illuminated Selector Switches (Assembled) con’t Part Numbers: 2–Position Selector Switches Style Part Number Part Number Part Number Operator Spring Return Spring Return from Position Maintained from Left Right A3 L R LR L L R R Knob ASW210 ASW2110 ASW2210 1 O X Lever ASW2L10 ASW21L10 ASW22L10 1NO 2 O O Key ASW2K10 ASW21K10 ASW22K10 Knob ASW201-116 ASW2101-116 ASW2201-116 1 X O Lever ASW2L01-116 ASW21L01-116 ASW22L01-116 1NC 2 O O Key ASW2K01-116 ASW21K01-116 ASW22K01-116 Knob ASW211 ASW2111 ASW2211 1NO 1 X O Lever ASW2L11 ASW21L11 ASW22L11 2 O X 1NC Key ASW2K11 ASW21K11 ASW22K11 Knob ASW220 ASW2120 ASW2220 1 O X Lever ASW2L20 ASW21L20 ASW22L20 2NO 2 O X Key ASW2K20 ASW21K20 ASW22K20 Knob ASW202-104 ASW2102-104 ASW2202-104 1 X O Lever ASW2L02-104 ASW21L02-104 ASW22L02-104 2NC 2 X O Key ASW2K02-104 ASW21K02-104 ASW22K02-104 1 O X Knob ASW222 ASW2122 ASW2222 2NO 2 X O Lever ASW2L22 ASW21L22 ASW22L22 3 O X 2NC Key ASW2K22 ASW21K22 ASW22K22 4 X O 1 O X Knob ASW222-111 ASW2122-111 ASW2222-111 2NO 2 O X Lever ASW2L22-111 ASW21L22-111 ASW22L22-111 3 X O 2NC Key ASW2K22-111 ASW21K22-111 ASW22K22-111 4 X O Part Numbers: 3–Position Selector Switches 1. The truth table indicates the operating position of Style Part Number Part Number Part Number Part Number contact block when the Operator Spring Return Spring Return Spring Return operator is switched to Maintained Position from Left Two-Way from Right that position. C C C C X = On (closed contacts) LC R L R L O = Off (open contacts) L L R R R X X = Overlapping Contacts: Remain on Knob ASW320 ASW3120 ASW3220 ASW3320 (closed contacts) when 1 X O O Lever ASW3L20 ASW31L20 ASW32L20 ASW33L20 2NO 2 O O X switch is moved between Key ASW3K20 ASW31K20 ASW32K20 ASW33K20 these two positions. Knob ASW302 ASW3102 ASW3202 ASW3302 2. All knob and lever selec- 1 O X X Lever ASW3L02 ASW31L02 ASW32L02 ASW33L02 2NC 2 X X O tor switches come in Key ASW3K02 ASW31K02 ASW32K02 ASW33K02 black. Other colors are 1 X O O available by ordering the Knob ASW322 ASW3122 ASW3222 ASW3322 2NO 2 O O X Lever ASW3L22 ASW31L22 ASW32L22 ASW33L22 knob or lever separately. 3 O X X 2NC Key ASW3K22 ASW31K22 ASW32K22 ASW33K22 3. Every key selector switch 4 X X O uses an identical key. The 1 X O X Knob ASW322-309 ASW3122-309 ASW3222-309 ASW3322-309 key is removable in any 2NO 2 X X O Lever ASW3L22-309 ASW31L22-309 ASW32L22-309 ASW33L22-309 maintained position. If a 3 O X O 2NC Key ASW3K22-309 ASW31K22-309 ASW32K22-309 ASW33K22-309 4 O O X different configuration is required, contact an IDEC 1 O X O Knob ASW322-310 ASW3122-310 ASW3222-310 ASW3322-310 representative for more 2NO 2 O O X Lever ASW3L22-310 ASW31L22-310 ASW32L22-310 ASW33L22-310 3 O X O information. 2NC Key ASW3K22-310 ASW31K22-310 ASW32K22-310 ASW33K22-310 4 O O X 4. Custom contact configura- tions are available, see 1 X O O Knob ASW340 ASW3140 ASW3240 ASW3340 2 O O X page A3-150 or contact Lever ASW3L40 ASW31L40 ASW32L40 ASW33L40 4NO 3 X O O IDEC for details. Key ASW3K40 ASW31K40 ASW32K40 ASW33K40 4 O O X 1 O X X Knob ASW304 ASW3104 ASW3204 ASW3304 2 X X O Lever ASW3L04 ASW31L04 ASW32L04 ASW33L04 4NC 3 O X X Key ASW3K04 ASW31K04 ASW32K04 ASW33K04 4 X X O www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-143 Contact Contact Mounting Mounting ø22mm - TW Series Oiltight Switches & Pilot Devices Non-Illuminated Selector Switches (Assembled) con’t Part Numbers: 4–Position Selector Switch Maintained Operator Position Part Number A3 1234 2 1 3 4 1 X O O O 2NO 2 O X O O Knob ASW422-411 3 O O X O Lever ASW4L22-411 2NC 4 O O O X Part Numbers: 5–Position Selector Switch Maintained Operator Position Part Number 12345 3 2 4 1 5 1 X O O O O 2NO 2 O X O O O Knob ASW522-501 3 O O O X O Lever ASW5L22-501 2NC 4 O O O O X A3-144 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Contact Contact Mounting Mounting Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Non-Illuminated Selector Switches (Sub-Assembled) † Contact Blocks + Operator + Knob or Lever * + Color Insert * = Complete Part A3 1. * Not needed with key type switches. † 2. Knob type shown. Part Numbers: Operators Part Numbers: Handles and Inserts Style Positions Description Part Number Style Part Number Maintained ASW200 Knob 2 Spring return from right ASW2100 ASWHHY-① Spring return from left ASW2200 Maintained, Cam 1 ASW300-1 Maintained, Cam 2 ASW300-2 Knob/Lever Lever Maintained, Cam 3 ASW300-3 Spring return from right, Cam 1 ASW3100-1 ASWHHL-① Spring return from right, Cam 2 ASW3100-2 3 Spring return from left, Cam 1 ASW3200-1 Spring return from left, Cam 2 ASW3200-2 Color Insert Spring return from left/right, Cam 1 ASW3300-1 Spring return from left/right, Cam 2 ASW3300-2 TW-HC1-① Maintained, Standard Cam ASW400 4 Maintained, Cam 1 ASW400-1 Maintained, Standard cam ASW500 5 Part Numbers: Contact Blocks Maintained, Cam 1 ASW500-1 Part Number Maintained ASW2K00 Style 2 Spring return from right ASW21K00 1NO 1NC Spring return from left ASW22K00 Key Standard Maintained, Cam 1 ASW3K00-1 HW-C10 HW-C01 Maintained, Cam 2 ASW3K00-2 Maintained, Cam 3 ASW3K00-3 HW-C10R HW-C01R Spring return from right, Cam 1 ASW31K00-1 (early make) (late break) Spring return from right, Cam 2 ASW31K00-2 3 Spring return from left, Cam 1 ASW32K00-1 Spring return from left, Cam 2 ASW32K00-2 Fingersafe (IP20) Spring return from left/right, Cam 1 ASW33K00-1 Spring return from left/right, Cam 2 ASW33K00-2 HW-F10 HW-F01 1. Two keys are supplied with every switch, all are keyed alike, and HW-F10R HW-F01R removable from any maintained position. For other configurations, (early make) (late break) consult your IDEC representative. 2. Locking rings are included with all operators. Order knobs, levers, and color inserts separately. Dummy Block 3. Different cams produce different contact actions. For details, see con- tact arrangement charts, page A3-150. TW-DB ① Handle/Insert Color Code Color Code Black* B 1. Push rod color code:Green = NO contact block Blue S Red = NC contact block. 2. Dummy blocks (no contacts) are used with an Green G odd number of contact blocks. Red R Yellow Y † W White * Color inserts not available in black. † Knob and lever not available in white. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-145 ø22mm - TW Series Oiltight Switches & Pilot Devices Illuminated Selector Switches (Assembled) A3 Assembled Illuminated Selector Switches ASLW2 (2) 99 11 (D) (N) - (202) - R - (24V) Function Lamp Voltage SL: Illuminated Selector Switch (Full Voltage Units Only) Series Designation 6V: 6V AC/DC W: TW Series 12V: 12V AC/DC Number of Positions 24V: 24V AC/DC 2: 2-Position 120V: 120V AC (LED only) 3: 3-Position 240V: 240V AC (LED only) Spring Return Action Lens Color Code Blank: Maintained A: Amber 1: Spring return from Right G: Green 2: Spring return from Left R: Red 3: Two-Way spring return from Left & Right S: Blue W: White Illumination Circuit Y: Yellow 99: Full Voltage (lamp determines voltage) Contact Circuit No. 126: 120V AC Step Down Transformer Standard circuits are listed on the follow- ing pages and A3-150. 246: 240V AC Step Down Transformer 486: 480V AC Step Down Transformer Contacts Terminal Style Blank: standard N: Fingersafe (IP20) Lamp Type Blank: Incandescent D: LED Contact Arrangement Code 10: 1NO 01: 1NC 20: 2NO 02: 2NC 40: 4NO 04: 4NC 11: 1NO-1NC 22: 2NO-2NC 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. All transformers step down to 6V (use 6V lamp). A3-146 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Illuminated Selector Switches (Assembled) con’t Part Numbers: Illuminated 2–Position Selector Switches➀ Transformer Voltage Code Style Part Number Voltage Code Operator Spring Return from Spring Return from 120V AC 126 Maintained Position Right Left 240V AC 246 A3 Lamp L R LR 480V AC 486 Circuit Type L L R R Transformers step down to 6V (use 6V lamp). 1NO 1 O X Transformer ASLW2 ➀ 11➃-➁ASLW21 ➀ 11➃-➁ASLW22 ➀ 11➃-➁ 2 X O Full Voltage ASLW29911➃-➁-➂ASLW219911➃-➁-➂ASLW229911➃-➁-➂1NC ➁ Lens Color Code 1 O X Transformer ASLW2 ➀ 20➃-➁ASLW21 ➀ 20➃-➁ASLW22 ➀ 20➃-➁ 2NO 2 O X Full Voltage ASLW29920➃-➁-➂ ASLW219920➃-➁-➂ASLW229920➃-➁-➂Color Code Color Code 1 X O Transformer ASLW2 ➀ 02➃-104-➁ASLW21 ➀ 02➃-104-➁ASLW22 ➀ 02➃-104-➁Amber A Blue S 2NC 2 X O Full Voltage ASLW29902➃-104-➁-➂ASLW219902➃-104-➁-➂ASLW229902➃-104-➁-➂ Green G White W 1 O X Red R Yellow Y 2NO 2 X O Transformer ASLW2 ➀ 22➃-➁ASLW21 ➀ 22➃-➁ASLW22 ➀ 22➃-➁ 3 O X Full Voltage ASLW29922➃-➁-➂ASLW219922➃-➁-➂ASLW229922➃-➁-➂2NC 4 X O Part Numbers: Illuminated 3–Position Selector Switches Maintained and Spring Return from Right Style Part Number Part Number Part Number Part Number Operator Spring Return Spring Return Spring Return from Left Maintained Position Two-Way From Right C Lamp C C C LC R Circuit Type L L R R L R L R 1 X O O Transformer ASLW3 ➀ 20➃-➁ASLW31 ➀ 20➃-➁ASLW32 ➀ 20➃-➁ASLW33 ➀ 20➃-➁ 2NO 2 O O X Full Voltage ASLW39920➃-➁-➂ASLW319920➃-➁-➂ASLW329920➃-➁-➂ASLW339920➃-➁-➂ 1 O X X Transformer ASLW3 ➀ 02➃-➁ ASLW31 ➀ 02➃-➁ ASLW32 ➀ 02➃-➁ASLW33 ➀ 02➃-➁ 2NC 2 X X O Full Voltage ASLW39902➃-➁-➂ ASLW319902➃-➁-➂ ASLW329902➃-➁-➂ASLW339902➃-➁-➂ 1 X O O 2NO 2 O O X Transformer ASLW3 ➀ 22➃-➁ASLW31 ➀ 22➃-➁ASLW32 ➀ 22➃-➁ASLW33 ➀ 22➃-➁ 3 O X X Full Voltage ASLW39922➃-➁-➂ASLW319922➃-➁-➂ASLW329922➃-➁-➂ASLW339922➃-➁-➂2NC 4 X X O 1 X O X 2NO 2 X X O Transformer ASLW3 ➀ 22➃-309-➁ASLW31 ➀ 22➃-309-➁ASLW32 ➀ 22➃-309-➁ASLW33 ➀ 22➃-309-➁ 3 O X O Full Voltage ASLW39922➃-309-➁-➂ASLW319922➃-309-➁-➂ASLW329922➃-309-➁-➂ASLW339922➃-309-➁-➂2NC 4 O O X 1 O X O 2NO 2 O O X Transformer ASLW3 ➀ 22➃-310-➁ASLW31 ➀ 22➃-310-➁ASLW32 ➀ 22➃-310- ➁ ASLW33 ➀ 22➃-310-➁ 3 O X O Full Voltage ASLW39922➃-310-➁-➂ASLW319922➃-310-➁-➂ASLW329922➃-310- ➁ -➂ASLW339922➃-310-➁-➂2NC 4 O O X 1 X O O 2 O O X Transformer ASLW3 ➀ 40➃-➁ASLW31 ➀ 40➃-➁ASLW32 ➀ 40➃-➁ASLW33 ➀ 40➃-➁ 4NO 3 X O O Full Voltage ASLW39940➃-➁-➂ASLW319940➃-➁-➂ASLW329940➃-➁-➂ASLW339940➃-➁-➂ 4 O O X 1 O X X 2 X X O Transformer ASLW3 ➀ 04➃-➁ASLW31 ➀ 04➃-➁ASLW32 ➀ 04➃-➁ASLW33 ➀ 04➃-➁ 4NC 3 O X X Full Voltage ASLW39904➃-➁-➂ASLW319904➃-➁-➂ASLW329904➃-➁-➂ASLW339904➃-➁-➂ 4 X X O 1. In place of ➀, specify the Transformer Voltage Code. ➂ Full Voltage Code➃ Lamp Type Code 2. In place of ➁, specify the Lens/LED Voltage Code Lamp Code Color Code. 6V AC/DC 6V Incandescent Blank 3. In place of ➂, specify the Full Voltage Code. 12V AC/DC 12V LED D 4. In place of ➃ specify Lamp Type Code 24V AC/DC 24V 5. For custom contact configuration, see 120V AC 120V (LED only) page A3-150. Contact IDEC for details. 240V AC 240V (LED only) www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-147 Contact Contact Mounting Mounting ø22mm - TW Series Oiltight Switches & Pilot Devices Illuminated Selector Switches (Sub-Assembled) Transformer* + Contact Block + Operator + Lamp/Lead Holder † + Lamp + Lens = Complete Part A3 1.* Full voltage units use a full voltage adaptor (TW-DA1B) instead of a transformer. 2. † Lamp holder is not included with operators, order separately. Lead holder is used when using 3 or more contact blocks. Order separately. Part Numbers: Operators Part Numbers: Lamps (LED) Part Type Voltage Part Number Positions Description Number 6V AC/DC LSTD-6➁ Maintained ASLW200 LED 12V AC/DC LSTD-1➁ 2 Spring return from right ASLW2100 24V AC/DC LSTD-2➁ Spring return from left ASLW2200 120V AC LSTD-H2➁ Maintained, cam 1 ASLW300-1 Maintained, cam 2 ASLW300-2 240V AC LSTD-M4➁ Maintained, cam 3 ASLW300-3 Incandescent Spring return from right, cam 1 ASLW3100-1 6V AC/DC IS-6 Spring return from right, cam 2 ASLW3100-2 3 12V AC/DC IS-12 Spring return from left, cam 1 ASLW3200-1 Spring return from left, cam 2 ASLW3200-2 24V AC/DC IS-24 Spring return from left/right, cam 1 ASLW3300-1 Spring return from left/right, cam 2 ASLW3300-2 1. In place of ➁, specify the LED Color Code. Different cams produce different contact action. For details, 2. The LED contains a current-limiting resistor and a Contact Arrangements on page A3-150. protection diodes. Part Numbers: Lenses (Knobs) ➁ LED/Lens Color Code Description Part Number Color Code Knob Amber A Green G ASLWLU-➁ Red R S Blue White W In place of ➁ specify Lens Color Code. Yellow Y A3-148 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Illuminated Selector Switches (Sub-Assembled) con’t Part Numbers: Contact Blocks Part Numbers: Transformers/Full Voltage Modules Style Description Part Number Description Part Number 120V AC TW-T126B 1NO 1NC Full Size Transformer Standard 240V AC TW-T246B A3 Standard 480V AC TW-T486B HW-C10 HW-C01 120V AC TW-F126B Fingersafe 240V AC TW-F246B HW-C10R HW-C01R (early make) (late break) 480V AC TW-F486B Half Size Transformer 120V AC TW-T126SB Fingersafe (IP20) HW-F10 HW-F01 240V AC TW-T246SB HW-F10R HW-F01R (early make) (late break) Full voltage model (use with Standard TW-DA1B even number of contacts) Dummy Block Fingersafe TW-DA1FB TW-DB Full voltage model (use with odd number of contacts) Standard HW-DA1B 1. Dummy blocks (no contacts) are used with an odd number of contact Fingersafe HW-DA1FB blocks. 2. Use of early and late break contacts creates a make before break function All Transformers step down to 6V (use 6V lamp). Part Numbers: Lamp Circuit Components Part Style Application Number Short Lamp Holder Used with a Half-size Trans- former and one contact TW-LH1 block Used with a Full-size Trans- Long Lamp Holder former and two contact blocks Used w/Half-size Trans- TW-LH2 former and three contact blocks Used w/Full Voltage Adap- tor and two contact blocks Lead Holder Used w/TW-LH2 holder when using four contact HW-LH3 blocks www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-149 ø22mm - TW Series Oiltight Switches & Pilot Devices Contact Arrangement Charts How to Read Contact Arrangement Charts To determine contact block mounting position, first make sure the selector switch is oriented as shown on the right 4 R 2 A3 Contact Arrangement L Mounting Positions Type and quantity of switch contacts Circuit Number 3 * N/D = No designation required 1 Contact Block Mounting Position Position or mounting contact blocks on operator Operator Position Truth table indicates the operating position of contact block when opera- tor is switched to that position. Contact Block Part Number Part number to use when ordering sub- assembly contact blocks, as required for use with corresponding mounting position Contact Arrangement Chart: 2-Position Selector Switches Style Operator Part Number Mounting Operator Contact Block Circuit Description Spring Ret. Spring Ret. Contact Position Position Part Number Maintained Number from Rt. from Lt. LR R L R L L R Knob/Lever ASW200 ASW2100 ASW2200 1O XHW-C10 1NO N/D Key ASW2K00 ASW21K00 ASW22K00 2O OTW-DB Illuminated Knob ASLW200 ASLW2100 ASLW2200 Knob/Lever ASW200 ASW2100 ASW2200 1X OHW-C01 1NC 116 Key ASW2K00 ASW21K00 ASW22K00 2O OTW-DB Illuminated Knob ASLW200 ASLW2100 ASLW2200 Knob/Lever ASW200 ASW2100 ASW2200 1O XHW-C10 N/D Key ASW2K00 ASW21K00 ASW22K00 2X OHW-C01 Illuminated Knob ASLW200 ASLW2100 ASLW2200 1NO 1NC Knob/Lever ASW200 ASW2100 ASW2200 1X OHW-C01 103 Key ASW2K00 ASW21K00 ASW22K00 2O XHW-C10 Illuminated Knob ASLW200 ASLW2100 ASLW2200 1O XHW-C10R Knob/Lever ASW200 ASW2100 ASW2200 600 Key ASW2K00 ASW21K00 ASW22K00 2X OHW-C01R Illuminated Knob ASLW200 ASLW2100 ASLW2200 1NO-EM 1NC-LB Knob/Lever ASW200 ASW2100 ASW2200 1X OHW-C01R 601 Key ASW2K00 ASW21K00 ASW22K00 2O XHW-C10R Illuminated Knob ASLW200 ASLW2100 ASLW2200 Knob/Lever ASW200 ASW2100 ASW2200 1O XHW-C10 2NO N/D Key ASW2K00 ASW21K00 ASW22K00 2O XHW-C10 Illuminated Knob ASLW200 ASLW2100 ASLW2200 Knob/Lever ASW200 ASW2100 ASW2200 1X OHW-C01 2NC 104 Key ASW2K00 ASW21K00 ASW22K00 2X OHW-C01 Illuminated Knob ASLW200 ASLW2100 ASLW2200 1O XHW-C10 Knob/Lever ASW200 ASW2100 ASW2200 2X OHW-C01 N/D Key ASW2K00 ASW21K00 ASW22K00 3O XHW-C10 Illuminated Knob ASLW200 ASLW2100 ASLW2200 2NO 4X OHW-C01 2NC 1O XHW-C10 Knob/Lever ASW200 ASW2100 ASW2200 2O XHW-C10 111 Key ASW2K00 ASW21K00 ASW22K00 3X OHW-C01 Illuminated Knob ASLW200 ASLW2100 ASLW2200 4X OHW-C01 1. NO-EM, NC-LB = Early Make, Late Break. N/D = No circuit number designation required in assembled selector switch part number. 2. X = On (closed contacts) O = Off (Open contacts) A3-150 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Contact Arrangement Chart: 3-Position Selector Switches Style Operator Part Number Mounting Operator Contact Block Circuit Description Spring Ret. Spring Ret. Contact Position Position Part Number Maintained Two-Way Number from Rt. from Lt. L C R C C C C L L L L R R R R Knob/Lever ASW300-1 ASW3100-1 ASW3200-1 ASW3300-1 1X 00 HW-C10 A3 202 Key ASW3K00-1 ASW31K00-1 ASW32K00-1 ASW33K00-1 2X XO HW-C01 Illuminated Knob ASLW300-1 ASLW3100-1 ASLW3200-1 ASLW3200-1 Knob/Lever ASW300-1 ASW3100-1 ASW3200-1 ASW3300-1 10 XX HW-C01 203 Key ASW3K00-1 ASW31K00-1 ASW32K00-1 ASW33K00-1 2O 0X HW-C10 Illuminated Knob ASLW300-1 ASLW3100-1 ASLW3200-1 ASLW3200-1 1NO 1NC Knob/Lever ASW300-2 ASW3100-2 ASW3200-2 ASW3300-2 1 X0X HW-C10 302 Key ASW3K00-2 ASW31K00-2 ASW32K00-2 ASW33K00-2 2X XO HW-C01 Illuminated Knob ASLW300-2 ASLW3100-2 ASLW3200-2 ASLW3200-2 10 XO HW-C01 Knob/Lever ASW300-2 ASW3100-2 ASW3200-2 ASW3300-2 303 Key ASW3K00-2 ASW31K00-2 ASW32K00-2 ASW33K00-2 2O 0X HW-C10 Illuminated Knob ASLW300-2 ASLW3100-2 ASLW3200-2 ASLW3200-2 Knob/Lever ASW300-1 ASW3100-1 ASW3200-1 ASW3300-1 1X 00 HW-C10 N/D Key ASW3K00-1 ASW31K00-1 ASW32K00-1 ASW33K00-1 2O 0X HW-C10 Illuminated Knob ASLW300-1 ASLW3100-1 ASLW3200-1 ASLW3200-1 2NO Knob/Lever ASW300-2 ASW3100-2 ASW3200-2 ASW3300-2 1 X0X HW-C10 301 Key ASW3K00-2 ASW31K00-2 ASW32K00-2 ASW33K00-2 2O 0X HW-C10 Illuminated Knob ASLW300-2 ASLW3100-2 ASLW3200-2 ASLW3200-2 Knob/Lever ASW300-2 ASW3100-2 ASW3200-2 ASW3300-2 10 XO HW-C01 304 Key ASW3K00-2 ASW31K00-2 ASW32K00-2 ASW33K00-2 2X XO HW-C01 Illuminated Knob ASLW300-2 ASLW3100-2 ASLW3200-2 ASLW3200-2 2NC Knob/Lever ASW300-1 ASW3100-1 ASW3200-1 ASW3300-1 10 XX HW-C01 N/D Key ASW3K00-1 ASW31K00-1 ASW32K00-1 ASW33K00-1 2X XO HW-C01 Illuminated Knob ASLW300-1 ASLW3100-1 ASLW3200-1 ASLW3200-1 1X 00 HW-C10 Knob/Lever ASW300-1 ASW3100-1 ASW3200-1 ASW3300-1 20 0X HW-C10 N/D Key ASW3K00-1 ASW31K00-1 ASW32K00-1 ASW33K00-1 30 XX HW-C01 Illuminated Knob ASLW300-1 ASLW3100-1 ASLW3200-1 ASLW3200-1 4X X0 HW-C01 10 XX HW-C01 Knob/Lever ASW300-1 ASW3100-1 ASW3200-1 ASW3300-1 20 0X HW-C10 210 Key ASW3K00-1 ASW31K00-1 ASW32K00-1 ASW33K00-1 30 XX HW-C01 Illuminated Knob ASLW300-1 ASLW3100-1 ASLW3200-1 ASLW3200-1 40 0X HW-C10 1 X0X HW-C10 Knob/Lever ASW300-2 ASW3100-2 ASW3200-2 ASW3300-2 2NO 2X X0 HW-C01 308 Key ASW3K00-2 ASW31K00-2 ASW32K00-2 ASW33K00-2 2NC 3 X0X HW-C10 Illuminated Knob ASLW300-2 ASLW3100-2 ASLW3200-2 ASLW3200-2 4X XO HW-C01 1 X0X HW-C10 Knob/Lever ASW300-2 ASW3100-2 ASW3200-2 ASW3300-2 2X X0 HW-C01 309 Key ASW3K00-2 ASW31K00-2 ASW32K00-2 ASW33K00-2 30 XO HW-C01 Illuminated Knob ASLW300-2 ASLW3100-2 ASLW3200-2 ASLW3200-2 4O 0X HW-C10 10 XO HW-C01 Knob/Lever ASW300-2 ASW3100-2 ASW3200-2 ASW3300-2 2O 0X HW-C10 310 Key ASW3K00-2 ASW31K00-2 ASW32K00-2 ASW33K00-2 30 XO HW-C01 Illuminated Knob ASLW300-2 ASLW3100-2 ASLW3200-2 ASLW3200-2 40 0X HW-C10 1X 00 HW-C10 Knob/Lever ASW300-1 ASW3100-1 ASW3200-1 ASW3300-1 20 0X HW-C10 N/D Key ASW3K00-1 ASW31K00-1 ASW32K00-1 ASW33K00-1 3X 00 HW-C10 Illuminated Knob ASLW300-1 ASLW3100-1 ASLW3200-1 ASLW3200-1 40 0X HW-C10 4NO 1 X0X HW-C10 Knob/Lever ASW300-2 ASW3100-2 ASW3200-2 ASW3300-2 20 0X HW-C10 305 Key ASW3K00-2 ASW31K00-2 ASW32K00-2 ASW33K00-2 3 X0X HW-C10 Illuminated Knob ASLW300-2 ASLW3100-2 ASLW3200-2 ASLW3200-2 40 0X HW-C10 10 XX HW-C01 Knob/Lever ASW300-1 ASW3100-1 ASW3200-1 ASW3300-1 2X X0 HW-C01 N/D Key ASW3K00-1 ASW31K00-1 ASW32K00-1 ASW33K00-1 30 XX HW-C01 Illuminated Knob ASLW300-1 ASLW3100-1 ASLW3200-1 ASLW3200-1 4X XO HW-C01 4NC 10 XO HW-C01 Knob/Lever ASW300-2 ASW3100-2 ASW3200-2 ASW3300-2 2X X0 HW-C01 314 Key ASW3K00-2 ASW31K00-2 ASW32K00-2 ASW33K00-2 30 XO HW-C01 Illuminated Knob ASLW300-2 ASLW3100-2 ASLW3200-2 ASLW3200-2 4X X0 HW-C01 1. Each operator sub-assembly is available as a “-1" and a “-2" for 3-position selector switches. The internal cam of a “-1" is different from that of a “-2". This results in designated combinations of open and closed contacts in the various operator positions. 2. N/D = No circuit number designation required in assembled part number. 3. X = On (closed contacts) O = Off (open contacts). X X Overlapping contacts remain on (closed) when switch is moved between these two positions. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-151 ø22mm - TW Series Oiltight Switches & Pilot Devices Custom Selector Switch Building Guide To build a custom selector switch, follow these steps. 4 Step1: How many positions of the switch are needed? R 2 L # of positions Mounting Positions A3 (2, 3, 4, 5) 3 Step 2: How many contacts should there be? # of isolated contacts 1 (maximum 6) Step 3: Fill in the Truth Table (X = closed, O = open) Knob Position 12345 1 C o 2 n 3 t a 4 c 5 t s 6 Step 4: If building a 2 position selector, skip this step. (2 position selectors have only one cam) If building a 3, 4, or 5 position selector, determine appropriate cam as follows: -Look at Row 1 from above table and locate an identical row in the operator truth tables (See next page). -Repeat for all rows. The user must Ţnd one operator that contains all rows from above table. -Record the operator cam version. Operator CAM Version (-1, -2, -3 for 3 position) (“blank”, -1 for 4 position) (“blank”, -1 for 5 position) Step 5: Build by placing appropriate contact in appropriate mounting position for each desired row on operator cam truth table. “L” and “R” refer to mounting on left or right side of operator as viewed from the front of the panel. Step 6: Develop an assembly part number (if necessary) as follows: follow standard numbering nomenclature for selector switches (see pages A3-142 or A3-146). In place of the “Circuit Number” indicate the cam number and contact arrangement as such ASW322-3-OELCSS, where “3” is the cam number, and contact arrangement “OELCXX” calls out individual contact mounting locations in order (see diagram above). O=NO, C=NC, E=NO-EM, L=NC-LB, X= no contact. Part number must designate all 6 possible mounting locations. Caution: Before putting any custom selector switch into use, the user should use an ohmmeter to test for desired performance. 1. For Operator Truth Tables, see next page. 2. For examples of how to assemble selector switches, see A3-82. A3-152 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Operator Truth Tables Use the following tables to build custom selector switches. 2 Position Selector Switches 4 Position Selector Switches Operator Position Operator Position Mounting Mounting Contact Contact Position A3 Position Left Right 1234 LO X LX OOO HW-C10 HW-C10 (NO) (NO) RO X R OXO O LX O LO X X X HW-C01 HW-C01 (NC) ASW200 (NC) RX O R XOX X ASLW200 ASW400 L0 X LX OOO HW-C10R ASW2K00 HW-C10R (NO-EM) (NO-EM) RO X R OXO O LX O LO X X X HW-C01R HW-C01R (NC-LB) (NC-LB) RX O R XOX X 3 Position Selector Switches Operator Position Mounting Contact Operator Position Position 1234 Mounting Contact Position Left Center Right LX OOO HW-C10 (NO) LX O O R OOO X HW-C10 (NO) RO O X LO OXO HW-C01 (NC) LO X X R OXO O HW-C01 ASW400-1 (NC) ASW300-1 RX X O LX XOX HW-C10R ASW3K00-1 (NO-EM) LX O O R XOX X HW-C10R ASLW300-1 (NO-EM) RO O X LO XXX HW-C01R (NC-LB) LO X X R XXX O HW-C01R (NC-LB) RX X O 5 Position Selector Switches Operator Position Operator Position Mounting Mounting Contact Contact Position Position 12345 Left Center Right L XOX LX OOOO HW-C10 HW-C10 (NO) (NO) RO O X R OX OOO L OXO LO O XXX HW-C01 HW-C01 (NC) (NC) ASW300-2 RX X O R OOO X X ASW500 ASW3K00-2 L XOX LX OOOO HW-C10R HW-C10R ASLW300-2 (NO-EM) (NO-EM) RO O X R OX OOO L OXO LO XXXX HW-C01R HW-C01R (NC-LB) (NC-LB) RX X O R XO XXX Operator Position Operator Position Mounting Mounting Contact Contact Position Left Center Right Position 12345 LX O O HW-C10 LX OOOO HW-C10 (NO) RO O X (NO) R OOOO X L OXO HW-C01 L OO OXO HW-C01 (NC) ASW300-3 R OXO (NC) R OX OOO ASW3K00-3 ASW500-1 L XOX HW-C10R L XX XOX ASLW300-3 HW-C10R (NO-EM) R XOX (NO-EM) R XO XXX LO X X HW-C01R LO XXXX HW-C01R (NC-LB) RX X O (NC-LB) R XXXX O www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-153 Y C N S T E ø22mm - TW Series Oiltight Switches & Pilot Devices Nameplates — TW Series Part Numbers: Nameplates NWAL NWAQL NWAS EMERGENCY STOP A3 1.13" (29mm) 1.76" (45mm) 1.13" (29mm) Yellow Part Number Part Number Part Number Part Number Nameplate NWAL-OB (black) NWAQL-OB (black) NWAS-OB NWAR-O NWAL-OR (red) NWAQL-OR (red) (blank) Nameplate † NWAL-➀NWAQL-➀NWAS-➀NWAR-27 (engraved) 1. In place of ➀, insert either the Standard Legend Code from table below or custom engraving delimited by “ “. 2. Standard engravings are available at no charge. 3NWAR-27 comes marked “Emergency Stop” as shown in drawing. Standard Legend Codes Pushbuttons Pushbuttons/Selector Switches Selector Switches Legend Code Legend Code Legend Code Legend Code Legend Code AUTO-MAN-OFF 301 AUTO 101 OPEN 116 AUTO-MAN 201 AUTO-OFF-MAN 302 CLOSE 102 OUT 117 CLOSE-OPEN 202 CLOSE-OFF-OPEN 303 DOWN 103 RAISE 118 DOWN-UP 203 DOWN-OFF-SLOW 304 EMERG.STOP* 104 RESET 119 FAST-SLOW 204 FAST-OFF-SLOW 305 REV-FOR 216 FAST 105 REVERSE 120 FOR-REV 205 FOR-OFF-REV 306 RUN-JOG 217 FORWARD 106 RUN 121 HAND-AUTO 206 LEFT-OFF-RIGHT 307 RUN-SAFE 218 HAND 107 SLOW 122 HIGH-LOW 207 LOWER-OFF-RAISE 308 SAFE-RUN 219 HIGH 108 START 123 JOG-RUN 208 OFF-MAN-AUTO 309 SLOW-FAST 220 IN 109 STOP* 124 LEFT-RIGHT 209 OFF-SLOW-FAST 310 START-STOP 221 INCH 110 STOP 125 LOWER-RAISE 210 OFF-1-2 311 STOP-START 222 JOG 111 TEST 126 MAN-AUTO 211 OPEN-OFF-CLOSE 312 UP-DOWN 223 LOW 112 UP 127 OFF-ON 212 SLOW-OFF-FAST 313 LOWER 113 I (Int’l On) 150 ON-OFF 213 SUMMER-OFF-WINTER 314 OFF 114 O (Int’l Off) 151 OPEN-CLOSE 214 UP-OFF-DOWN 315 ON 115 EMO 152 RAISE-LOWER 215 1-OFF-2 316 HAND-OFF-AUTO 317 1. To order engraved nameplates, add legend code to nameplate part number. Character height based on the number of characters and size of nameplate. Standard character size is 3/16". 2. Nameplates with standard legends are the same list price as blank nameplates. 3. * Available in red as standard. Nameplate Order Form on next page. A3-154 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC G O R P E M E Ø 70 Switches & Pilot Devices 1.0" (25.4mm) 0.566" 0.975" (14.5mm) (25mm) 1.76" (45mm) Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Custom Engraved Nameplates Order Form — TW Series Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. To insure engraving accuracy, fax it to your IDEC representative. or Distributor. Your Company Name: IDEC Rep/Distributor Contact: Your Name: PO number (if known): Telephone: IDEC Rep/Distributor Phone: A3 Fax & Email IDEC Rep/Distributor Fax & Email NWAL Step 1. 7/64” 11 characters max Choose Letter Size - 7/64” or 1/8”. Letter Engraving (for 7/64” size letters) Check the box for the letter size you want. Size Location Then write your lettering in box below checkboxes. Note: 1/8” size letters cannot 1/8” 9 characters max Letter exceed 9 characters. (for 1/8” size letters) Size Step 2. Sample Letter Sizes Specify Quantity. 7/64” Letters: A B C D Enter the number of 1/8” Letters: A B C D nameplates desired in Qty the box on the right. 1 2 3 4 5 6 7 8 9 10 11 NWAQL Step 1. 7/64” 11 characters max Choose Letter Size - 7/64” or 1/8”. Letter (for 7/64” size letters) Engraving Check the box for the letter size you want. Size Location Then write your lettering in box below checkboxes. Note: 1/8” size letters can- 1/8” 9 characters max Letter not exceed 9 characters. (for 1/8” size letters) Size Step 2. Sample Letter Sizes Specify Quantity. 7/64” Letters: A B C D Enter the number of nameplates desired in 1/8” Letters: A B C D Qty the box on the right. 1 2 3 4 5 6 7 8 9 10 11 NWAS Step 1. 3/32” 20 characters maximum Choose Letter Size - 1/8” Letter Engraving Location A (for 3/32” size letters) or 3/32”. Size Check the box for the letter size you want. Then write your 1/8” 14 characters maximum lettering in box below check- Letter (for 1/8” size letters) Size boxes. Note: 1/8” size letters cannot exceed 14 characters. Engraving Location B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Step 2. Step 3. Sample Letter Sizes Specify Quantity. Specify Location. 3/32” Letters: A B C D Enter the number of Enter the location of 1/8” Letters: A B C D nameplates desired in engraving (A or B), in Qty Location box on the right. box on the right. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-155 ø22mm - TW Series Oiltight Switches & Pilot Devices Accessories — TW Series Part Numbers: TW Series Accessories Appearance Description/Usage Part Number Lamp Removal Rubber tool used to install LED’s and incandescent lamps OR-55 A3 Tool Contact Block Used to remove contact blocks, transformers, lenses, and adaptors. Can also be TW-KC1 used to determine panel thickness adjustment. Remover Nut Locking Used in OR-14 locking wrench to tighten locking nuts inside square bezel TW-KQ2 Wrench Standard octagonal units (chrome-pl.) AW-R8 Chrome plated bezels tighten onto operator Metal Bezel Full shroud octagonal units (chrome-pl.) AW-RF8 (replacement for dam- aged bezels) Full shroud (chrome plated) mushroom head AW-G4 units Ş 40mm Round ţush units (black plastic) AW-RP1B Round extended units (black plastic) AW-FP1B Black plastic bezels for square buttons Plastic Bezel Square units (black plastic) AW-Q1B (replacement for dam- aged bezels) Square bezel with round hole (black plastic) AW-H1B Square units with full shroud (black plastic) AW-QF1B Waterproof lens cover for square pilot lights APW00LN Waterproof lens cover for square illuminated buttons APW00L Used to cover and pro- Clear boot for round ţush units (EPR) OC-31 Boot/Cover tect pushbuttons Clear boot for round extended units (EPR) OC-32 *In place of asterisk, specify Rubber Boot color: OCW-11* B (black), G (green), R (red), Y (yellow) - (nitril rubber) Ring to prevent operator base from rotating in the mounting hole. Anti-Rotation OGL-31 Ring Used when nameplate is not used Mounting Black rubber plug Ţlls unused mounting holes in panel. OB-31 Hole Plug For plugging unused mounting holes in the panel. Tighten the attached locking ring Metallic to a torque of 12 kfg-cm maximum Mounting Hole LW9Z-BM Plug Degree of protection: IP66 Replacement Pair of keys (#0) TW-SK Keys For information on replacement engraving inserts, see page A3-164. A3-156 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Accessories con’t Part Numbers: TW Series Accessories Appearance Description/Usage Part Number Metal Button Guard A3 Used on ţush buttons to prevent inadvertent actuation OLW-C Terminal Tab Adaptor Quick- connect terminals #250 (17/64" x 3/64") single tab TW-FA1 Lock-out Adaptor Used to provide lock-out protection for pushbuttons and knob selector switches: • Up to Ş 40mm mushroom head size HW9Z-KL1 (Padlock not included.) TW to TWTD Adaptor Adaptor Used to mount TW series control unit (except square units) Ş 7/8" (22mm) TWN-A1R8 into a Ş 1-13/64" (30mm) panel cut-out. Includes 2 pieces shown on the right Fits on TW unit base Round Pushbutton (Ş14mm) ALW2B Replacement Marking Plates White plastic engraving plate for use on all Round Pilot Light (Ş 14mm) APW2B illuminated units (included in each lens). Mushroom Pushbutton (Ş 14mm) ALW3B May be used to capture printed mylar insert Square Pilot Light (❑ 21mm) APQW1B (not supplied by IDEC) under lens face. Square Pushbutton (❑ 21mm) ALQW2B Part Numbers: Fingersafe Covers for TW Series Appearance Description Used with Part Number Fingersafe terminal cover, adds APW and UPQW full voltage pilot lights APS-PVL 6mm to overall depth Fingersafe terminal cover, adds 3.5mm to overall depth. One Non-illuminated pushbuttons and selectors HW-VL2 required for each contact, only for rear- most terminals Fingersafe terminal cover, adds APW and UPQW transformer pilot lights, and 3mm to overall depth illuminated pushbuttons and illuminated HW-VL3 selectors Fingersafe terminal cover for Full voltage illuminated pushbuttons and HW-VL4 contacts. selectors Fingersafe terminal cover for Full voltage illuminated pushbuttons and HW VL5 full voltage adaptor, adds 3 mm HW-VL5 selectors to depth Fingersafe terminal cover for half size transformer adaptor, Illuminated pushbuttons and selectors HW-VL6 adds 3 mm to depth www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-157 HW VL6 HW-VL3 APS-PVL 45° 45° ø22mm - TW Series Oiltight Switches & Pilot Devices Dimensions — TW Series Pushbuttons Flush Extended Extended with Full Shroud M3.5 M3.5 M3.5 Terminal Screw Terminal Screw Terminal Screw Panel Thickness: 1 to 6 mm Panel Thickness: 1 to 6 mm Panel Thickness: 1 to 6 mm A3 ( ) ( ) 48.5 2 blocks 13 48.5 2 blocks 13 48.5 (2 blocks) 19.5 30 68.5 (4 blocks) 30 ( ) 68.5 (4 blocks) 19 30 68.5 4 blocks 29mm Mushroom Mushroom with Full Shroud 40mm Mushroom M3.5 M3.5 Panel Thickness: 1 to 6 mm M3.5 Terminal Screw Terminal Screw Panel Thickness: 1 to 6 mm Panel Thickness: 1 to 6 mm Terminal Screw 48.5 (2 blocks) 13 ( ) 48.5 (2 blocks) 48.5 2 blocks 13 22.5 30 ( ) 23 30 68.5 (4 blocks) 68.5 4 blocks 68.5 (4 blocks) 22.5 30 Keylock Push On/Off 40mm Push-Lock-Turn-Reset 29mm Push-Lock-Turn-Reset M3.5 Panel Thickness: 1 to 6 mm M3.5 Panel Thickness: 1 to 6 mm Panel Thickness: 1 to 6 mm M3.5 Terminal Screw Terminal Screw Resetting Resetting angle 75° Terminal Screw Resetting angle 75° (Unlock) 13 ( ) 13 48.5 (2 blocks) 25 48.5 2 blocks 48.5 (2 blocks) 13 ( ) 47 30 30 68.5 (4 blocks) 22.5 30 68.5 4 blocks 68.5 (4 blocks) 22.5 40mm Push-Pull Square Flush 40mm Pushlock Key Reset M3.5 M3.5 Panel Thickness: 1 to 6 mm M3.5 Panel Thickness: 1 to 6 mm Terminal Screw Terminal Screw Panel Thickness: 1 to 6 mm Resetting Terminal Screw (Unlock) 13 13 ( ) 48.5 2 blocks 25 48.5 (2 blocks) 13 ( ) 25 48.5 2 blocks 68.5 (4 blocks) 30.5 30 68.5 (4 blocks) 30 ( ) 47 30 68.5 4 blocks Square Extended M3.5 Terminal Screw Panel Thickness: 1 to 6 mm ( ) 48.5 2 blocks 13 20 30 68.5 (4 blocks) Selector Switches M3.5 Terminal M3.5 Terminal M3.5 Terminal Screw Screw Panel Thickness 1 to 6 mm Screw Panel Thickness 1 to 6 mm Panel Thickness: 1 to 6 mm 13 48.5 (2 blocks) (2 blocks) 48.5 (2 blocks) 13 48.5 19 13 68.5 (4 blocks) 30 68.5 (4 blocks) 25 30 25 68.5 (4 blocks) 30 41 A3-158 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices ø24 ø29 ø29 25 ø29 30 ø24 ø40 ø29 37 37 37 37 37 37 ø40 ø24 ø40 ø29 ø40 ø29 ø25 37 37 37 37 37 30 ø46 ø24 25 ø29 ø29 ø24 37 37 37 ø29 37 37 Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Dimensions con’t Illuminated Pushbuttons Extended Extended with Full Shroud Illuminated Dimension A Dimension B Panel Thickness: 1 to 6 mm Panel Thickness: 1 to 6 mm Pushbuttons A3 Extended 0.741" (19mm) Ş 0.936" (Ş24mm) (Same for Square) ❏0.975" (❏25mm) 0.761" (19.5mm) w/Full Shroud 13 20 30 Ş 1.13" (29mm) 30 19 Marking Plate: ø15.5 mm Mushroom Marking Plate: ø15.5 mm 0.858" (22mm) Ş 1.13" (29mm) Ş 1.56" (40mm) 0.858" (22mm) Ş 1.56" (40mm) Square Extended 29mm Push-Turn Reset *0.936" (24mm) Ş 1.56" (40mm) Mushroom, † 0.975" (25mm) Ş 1.56" (40mm) Panel Thickness: 1 to 6 mm Pushlock Turn Panel Thickness: 1 to 6 mm Resetting Angle: 75° Reset, Push-Pull 1. * Dimension when operator is in reset position. 2. † Dimension when operator is in pull position. 13 13 30 20 30 22.5 Marking Plate: 21 mm Marking Plate: ø13.9 mm Push-Pull 40mm Push-Turn Reset Mushroom Panel Thickness: 1 to 6 mm Panel Thickness: 1 to 6 mm Panel Thickness: 1 to 6 mm Resetting angle: 75° 13 13 13 30 25 30 22.5 30 22.5 30.5 Marking Plate: ø13.9 mm Marking Plate: ø13.9 mm Marking Plate: ø13.9 mm Illuminated Selector Switches 1 Contact Block 1 Contact Block with Transformer (2 blocks) with Half Size Transformer Full Voltage Adaptor Panel Thickness: 1 to 6 mm M3.5 Terminal Screw M3.5 Terminal Screw Panel Thickness: 1 to 6 mm X1 Panel Thickness: 1 to 6 mm X2 48.5 86.5 64.5 2 Contact Blocks with 2 Contact Blocks Transformer (4 blocks) Full Voltage Adaptor with Half Size Transformer Panel Thickness: 1 to 6 m M3.5 Terminal Screw X1 M3.5 Terminal Screw Panel Thickness: 1 to 6 mm Panel Thickness: 1 to 6 mm X2 106.5 63.5 68.5 3 Contact Blocks with 4 Contact Blocks with 3 Contact Blocks Full Voltage Adaptor Full Voltage Adaptor with Half Size Transformer M3.5 Terminal Screw Panel Thickness: 1 to 6 mm M3.5 Terminal Screw Panel Thickness: 1 Panel Thickness: 1 to 6 mm 68.5 83.5 M3.5 Terminal Screw 84.5 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-159 X1 X2 X1 X1 X2 X2 X1 X2 X2 X1 X2 X1 ø40 ø24 25 ø29 30 37 37 37 X2 X1 ø24 ø29 ø29 ø29 37 37 37 ø40 37 ø22mm - TW Series Oiltight Switches & Pilot Devices Dimensions con’t Pilot Lights Round Flush APW1 Full Voltage Round Flush APW1 Transformer Panel Thickness Panel Thickness 1 to 6 1 to 6 M3.5 Terminal Screw A3 28.5 13 30 28.5 13 30 66.5 17 17 Round Flush Marking Type APW1B Full Voltage Round Flush Marking Type APW1B Transformer Panel Thickness M3.5 Terminal Panel Thickness 1 to 6 Screw 1 to 6 28.5 13 30 28.5 13 30 17 66.5 17 Marking plate: ø15.5 mm Marking plate: ø15.5 mm Dome APW2 Full Voltage Dome APW2 Transformer Panel Thickness M3.5 Terminal Panel Thickness 1 to 6 Screw 1 to 6 28.5 13 30 28.5 13 30 25 66.5 25 Square Flush Marking Type APQW1B Full Voltage Square Flush Marking Type APQW1B Transformer Panel Thickness M3.5 Terminal 1 to 6 Screw Panel Thickness 1 to 6 28.5 13 30 28.5 13 30 16 16 66.5 Marking plate: 22 mm Marking plate: 22 mm Illuminated Selector Switches M3.5 Terminal Screw Panel Thickness: 1 to 6 mm 13 A: 63.5 (2 blocks) 30 25 83.5 (4 blocks) B: 86.5 (2 blocks), 106.5 (4 blocks) A: Rated voltage 24V AC/DC B: Rated voltage 100/110V AC, 200/220V AC A3-160 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices 25 ø24 ø24 ø23.6 30 ø29 ø29 ø24 ø29 ø29 37 37 37 37 37 ø24 25 ø23.6 ø29 ø24 30 ø29 ø29 37 37 37 37 Switches & Pilot Devices R66.5 ø22.2 Oiltight Switches & Pilot Devices ø22mm - TW Series Dimensions con’t Panel Cut-Out Dimensions Diagram Part A B C D Pushbuttons A 1.17" (30mm) A3 Std. Octagonal Pilot Light > 1.56" (40mm) Large Illuminated Mushroom 1.95" (50mm); Ş 0.137" Ş 0.878" Pushbutton C 1.76" (45mm) B (3.5mm) (22.3mm) minimum Selector Switches 1.17" (30mm) *See note. Illuminated Selector Switches D 1.The Ø 0.137" (Ø 3.5mm) recess is necessary when either the nameplate or anti-rotation ring is used. 2. * >1.404" (36mm) for 2- or 3-position. >1.95" (50mm) for 4- or 5-position. Accessory Dimensions OCW-11 OGL-31 OLW-C OB-31 Anti-Rotation Ring Pushbutton Rubber Boot Mounting Hole Rubber Plug Metal Button Guard 0.398" Ø1.29" Ø0.897" Ø1.13" (10.2mm) 0.137" Minimum (Ø33mm) (Ø23mm) (Ø29mm) 0.137" (3.5mm) Mounting (3.5mm) Centers 1.95" Ø0.858" 0.429" (11mm) Ø1.07" (50mm) (22mm) Ø0.975" (Ø27.4mm) 0.741" (19mm) (Ø25mm) R1.66" (R42.5mm) AW-FP1B AW-RP1B HW9Z-KL1 (TW) Round Plastic Bezel Round Plastic Lock-out Adaptor w/Full Shroud 0.507" 82.5 (13mm) Panel Thickness: 0.8 to 3.2 mm 0.772" (19.8mm) Ø1.13" (Ø29mm) Ø1.13" (Ø29mm) ID: 24 29.5 Waterproof Gasket Lock Hole ø8 0.5t 30 AW-QF1B AW-H1B Square Full Shroud Square Bezel w/ Round Hole 0.78" (20mm) 0.507" (13mm) ❏1.17" (❏30mm) ❏1.17" (❏30mm) www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-161 ø 50 (ID: ø 44.4) 70 30 93 ø22mm - TW Series Oiltight Switches & Pilot Devices Dimensions con’t Finger-Safe Cover Dimensions HW-VL6 HW-VL5 HW-VL4 1.57" (39.8mm) A3 0.28" (7.2mm) 0.90" (22.8mm) 0.34" (8.7mm) 1.06" (27mm) 0.61" HW VL5 (15.5mm) 1.54" (39.1mm) 1.41" (10.4mm) 1.58" (40mm) APS-PVL HW-VL3 HW-VL2 (1.57" 39.8mm) .748" (19mm) .055" (14.1mm) HW-VL3 APS-PVL .271" 0.12" .228" .421" 0.61" (6.9mm) (5.8mm) (10.7mm) 1.02" (3mm) (15.5mm) 0.41" (26mm) 1.16" (29.4mm) (10.4mm) A3-162 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC .248" (6.3mm) R 0.122" (3.1mm) 0.24" (6.2mm) 0.26" (6.5mm) 0.275" (7mm) Switches & Pilot Devices 1.49" (37.8mm) 0.58" 0.69" (14.8mm) 0.79" (20mm) (17.4mm) HW VL6 1.42" (36mm) .244" (6.2mm) 1.02" (26mm) Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Component Construction & Instructions — TW Series Instructions for Switches and Pilot Devices Lens or Button TW Series: Adjustment for Panel Thickness A3 The panel thickness ring provides adjustment from 0.04" to 0.24" (1 to 6mm) in 0.004" (0.1mm) increments. Rotate the ring until the markings around the periphery are aligned for the desired thickness, as shown below. Bezel Option: Adjustment Examples Nameplate Zero Zero Operator Point Point One Complete Revolution (Panel) Waterproof Lens (Round lens used on Panel Thickness: square pushbuttons Waterproof and pilot lights only). 0.08" (2mm) Gasket 0.1mm panel thickness Adjustment Ring Base 0.5mm panel Panel Thickness) thickness Note: When a nameplate or an anti-rotation ring is used, add 0.03" (0.8mm) to the Panel Thickness: panel thickness dimension. 0.1" (2.6mm) Lamp An adjustment for panel thicknesses shown below can be made quickly by Lamp LED or Incandescent using the contact block remover tool. Holder Inspection 0.06" Window (1.6mm) Tool TW-KC1 Contact 0.09" (2.3mm) Lead Block Holder 0.14" (3.5mm) 0.04" (1mm) 0.08" (2mm) 0.125" (3.2mm) Options Full Voltage Full-Size Half-Size Adaptor: Transformer: Transformer: Used with Used with Used with full voltage incandescent/LED incandescent LED or – even number – odd number incandescent. of contact blocks. of contact blocks. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-163 0mm 0.1mm 0.2mm 0.3mm 0.4mm 0.5mm 0.6mm 0.7mm 0.8mm 0.9mm 0mm ø22mm - TW Series Oiltight Switches & Pilot Devices Instructions con’t Pilot Lights and Pushbuttons IMPORTANT: Install the body of the TW control unit with the panel thickness scale facing up. A3 Octagonal and Round Bezels Octagonal and round bezels screw into the operator. Use the locking ring wrench (optional) for secure tightening and easy removal. Round ţush and extended but- tons snap onto the operator base. Mushroom buttons screw onto the operator base. Every round lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be printed and placed in the lens. Round Marking Insert Press in Unit marking round flush plate and extended under lens. lens. Screw in mushroom lens. Square Bezels Square bezels are installed in a 3-step procedure. First install the base plate from the front. Then install the lock nut using the nut locking wrench (optional). Finally, install the square bezel, which snap-Ţts onto the base plate. Square buttons also snap onto the operator base. Every square lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be printed and placed in the lens. Square units include a round waterproof lens which screws into the operator. The square outer lens snaps on. Pilot Light Illuminated Square Pushbutton Marking Units Insert Insert marking marking plate plate under lens. under lens. To remove square lens from operator, place a screwdriver under the indentation on the side of the lens. To remove the marking plate, place a screwdriver under the indentation and lift out the plate. The lens retainer can be removed by pressing a 3/16" screwdriver into one of the recesses. Marking Plate Engraving Area Shape Engraving Area Used With Part Number Ş 0.55" (14mm) Illuminated pushbuttons ALW2B Round Ş 0.55" (14mm) Pilot lights APW2B Mushroom Ş 0.55" (14mm) Illuminated mushroom ALW3B Square❑ 0.83" (21mm) Square pilot lights APQW1B Square illuminated Square❑ 0.83" (21mm) ALQW2B pushbuttons A3-164 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Instructions con’t Selector Switches The operator shaft of each unit has a recess to identify in which direction to install the handle. Align the handle with the recess. Press color insert (TW-HC1) into the handle and then press handle into the operator, as shown below. A3 Recess Press in color insert Press in handle Illuminated Non-Illuminated Selector Switch Selector Switch . Remove color insert before pulling out the handle. Standard Operating Positions 2-Position, 90° 3-Position, 45° 4-Position, 45° 5-Position, 30° 0 2 3 1 2 1 2 1 4 2 3 5 1 4 Positions: Non-illuminated 3-Position Operators 1 1 0 0 1 2 0 2 2 Installation TW Pilot Lights Terminal X1 = Positive Terminal X2 = Negative Make sure slot is facing up TW Illuminated Pushbuttons, TW Selector Switches (AC Transformer or Full Voltage) Lamp holder is installed as shown, due to polarity. Lead holder (used with two stacks of contact blocks) does not have polarity. Installation of LED Illuminated Units AC transformers are recommended for use in areas subjected to inductive noise. When using full voltage types, install a protection diode as shown below. (Diode with DC power supply to protect against surges and noise.) Terminal LED Terminal X1 X2 Diode . Make sure that LED illuminated units are installed with correct polarity, as indicated at the terminals. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-165 ø30mm - TWTD Series Oiltight Switches & Pilot Devices TWTD Series — Full Size NEMA Pushbuttons A4 TWTD Series: Heavy duty switches built to last Key features include: The rugged series of TWTD switches offers both variety and durability in an attractive design. •Variety of button sizes up to 2 9/16" (65mm) • Rugged construction includes chrome plated zinc With button sizes up to 2 9/16" (65mm), chrome plated zinc locking locking ring die cast zinc mounting threads, screw rings, die cast zinc mounting threads, steel anti-rotation rings, and self mounted contact blocks cleaning contacts, the TWTD's are here to stay. • LED or incandescent illumination •Transformer or full voltage The TWTD series also offers either LED or incandescent illumination in full •Transparent contact windows voltage and transformer models. • Slow make, double break self cleaning contacts • Modular construction for maximum ţexibility Transparent contact windows allow the viewing of IDEC's self cleaning • Double nickel plated terminal screws slow-make/slow-break contacts. •Available assembled or as sub-components Regardless of your switching needs, the TWTD series provides the kind of • NEMA 4x and IP65 watertight/oiltight panel long lasting, industrial strength quality you've come to expect from • Large M3.5 screw terminals with captive sems plate IDEC. CertiŢcate No. UL Listed File No. LR48366 Ref. No. 117617MC 2005010305145658 File No. E70646 A4-166 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø30mm - TWTD Series Conforming to Standards EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14 Approvals CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) UL: pushbuttons and selector switches: A600 UL Listed File No. LR48366 pilot lights and illuminated pushbuttons, direct supply A4 pilot lights and illuminated pushbuttons with integral transformer File No. E70646 (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) TÜV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) Ref. No. 117617MC ) Operation: –25 to +50°C (without freezing) Operating Temperature Storage: –40 to +70°C (without freezing) 2 Vibration Resistance 10 to 55Hz, 98m/sec (10g) conforming to IEC6068-2-6 2 Shock Resistance 980m/sec (100g) conforming to IEC6068-2-7 Electric Shock Protection Class 0 conforming to IEC60536 IP65 (from front of the panel) (conforming to IEC60529) Degree of Protection IP54 (key switches) NEMA 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (conforming to NEMA ICS6-110) Momentary pushbuttons: 5,000,000 (900 operations per hour) Mechanical Life All other switches: 500,000 Pollution Degree 3 for switches not using a transformer 2 for switches using a transformer (conforming to IEC60947-1) AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB) Rated Operational Characteristics DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC) DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB) Rated Insulation Voltage 600V Rated Switching Over-Voltage Less than 4kV, conforming to IEC60947-1 4kV for contact circuit Rated Impulse Withstanding Voltage 2.5kV for lamp circuit Rated Thermal Current 10 Amp Minimum Switching Capacity 5 mA at 3V AC/DC Contact Operation Slow break NC or NO, self-cleaning Flush and extended pushbuttons—with 1NO or 1NC contact: 6.2±2N (momentary), Operating Force 7.0±2N (maintained) Additional contacts—1NO or 1NC: +3.2N (momentary), + 3.3N (maintained) Terminal Referencing Conforming to CENELEC EN50005 Recommended Terminal Torque 0.8 N m (7.1 in lb.) External Short-Circuit Protection 10A 250V fuse conforming to IEC60269-1 Applicable Wire Size Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG Contact Resistance Initial contact resistance of 50mΩ or less 4mm (NO and NC) Contact Gap 2mm (NO-EM and NC-LB) Incandescent: 1 W Lamp Ratings LEDs: 6, 12, 24V: 20mA / 120, 240V: 10mA Maximum Inrush Current 40 A (40 msec) Contact Material Silver AC-15 (A600) Contact Ratings by Utilization Category IEC 60947-5-1 DC-13 (P600) Contact Ratings by Utilization Category Operational Voltage 24V 48V 50V 110V 220V 440V — AC AC-12 Control of resistive loads & solid state loads 10A 10A 10A 6A 2A 50/60 — AC-15 Control of electromagnetic loads (> 72VA) 10A 7A 5A 3A 1A Hz Operation Current — — DC-12 Control of resistive loads & solid state loads 8A 5A 2.2A 1.1A DC — — DC-13 Control of electromagnets 5A 2A 1.1A 0.6A www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-167 Contact Ratings Mechanical-Electrical Specifications Specifications ø30mm - TWTD Series Oiltight Switches & Pilot Devices Non-Illuminated Pushbuttons (Assembled) A4 Assembled Pushbuttons AB()D110N-B Function Button Color B: Momentary B: Black G: Green O: Maintained R: Red S: Blue V: Pushlock Turn Reset W: White Y: Yellow Y: Push-Pull Contact Arrangement Bezel Shape 10: 1NO 01: 1NC Blank: Octagonal 20: 2NO 02: 2NC F: Full Shroud 11: 1NO-1NC 22: 2NO-2NC G: Mushroom Shroud Button Shape P: Neoprene Boot 1: Flush Series Designation 2: Extended D: TWTD Series 3: Mushroom Ø 40mm 4: Jumbo Mushroom Ø 65mm 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Custom contact configurations available, contact IDEC for details. A4-168 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø30mm - TWTD Series Non-Illuminated Pushbuttons (Assembled) con’t Part Numbers: Non-Illuminated Pushbuttons Part Number Style Contacts Momentary Maintained Flush 1NO ABD110N-➀AOD110N-➀A4 1NC ABD101N-➀AOD101N-➀ 1. In place of ➀, specify the Button 1NO-1NC ABD111N-➀AOD111N-➀ Color Code. 2NO ABD120N-➀AOD120N-➀ 2NC ABD102N-➀AOD102N-➀2. For sub-assembly part numbers, see next page. Extended 1NO ABD210N-➀AOD210N-➀ 3. For accessories, see page A4-188. 1NC ABD201N-➀AOD201N-➀ 4. † Neoprene boot available only in 1NO-1NC ABD211N-➀AOD211N-➀ 2NO ABD220N-➀AOD220N-➀Black (B), Green (G), Red (R) and 2NC ABD202N-➀AOD202N-➀ Yellow (Y). Extended with Neoprene 1NO ABPD210N-➀AOPD210N-➀ 1NC ABPD201N-➀AOPD201N-➀Boot 1NO-1NC ABPD211N-➀AOPD211N-➀ 2NO ABPD220N-➀AOPD220N-➀ 2NC ABPD202N-➀AOPD202N-➀ 1NO ABFD110N-➀AOFD110N-➀Recessed 1NC ABFD101N-➀AOFD101N-➀ 1NO-1NC ABFD111N-➀AOFD111N-➀ 2NO ABFD120N-➀AOFD120N-➀ 2NC ABFD102N-➀AOFD102N-➀① Button Color Code Color Code Extended with Full 1NO ABFD210N-➀AOFD210N-➀ 1NC ABFD201N-➀AOFD201N-➀Shroud Black B 1NO-1NC ABFD211N-➀AOFD211N-➀ 2NO ABFD220N-➀AOFD220N-➀Green G 2NC ABFD202N-➀ AOFD202N-➀ Red R Ş 40mm 1NO ABD310N-➀ AOD310N-➀ Blue S 1NC ABD301N-➀ AOD301N-➀ Mushroom Head 1NO-1NC ABD311N-➀ AOD311N-➀ White W 2NO ABD320N-➀ AOD320N-➀ 2NC ABD302N-➀ AOD302N-➀Yellow Y Ş 40mm 1NO ABGD310N-➀AOGD310N-➀1. 65mm Jumbo mushroom not 1NC ABGD301N-➀AOGD301N-➀Mushroom Head with available in white. 1NO-1NC ABGD311N-➀AOGD311N-➀ Full Shroud 2. Neoprene boot is not avail- 2NO ABGD320N-➀AOGD320N-➀ 2NC ABGD302N-➀ AOGD302N-➀ able in blue or white. Ş 65mm 1NO ABD410N-➀AOD410N-➀ Jumbo Mushroom Head 1NC ABD401N-➀AOD401N-➀ 1NO-1NC ABD411N-➀AOD411N-➀ 2NO ABD420N-➀AOD420N-➀ 2NC ABD402N-➀ AOD402N-➀ Ş 65mm 1NO ABGD410N-➀AOGD410N-➀ 1NC ABGD401N-➀AOGD401N-➀Jumbo Mushroom Head 1NO-1NC ABGD411N-➀AOGD411N-➀ with Shallow Shroud 2NO ABGD420N-➀AOGD420N-➀ 2NC ABGD402N-➀ AOGD402N-➀ Ş 65mm 1NO ABFD410N-➀AOFD410N-➀ Jumbo Mushroom Head 1NC ABFD401N-➀AOFD401N-➀ 1NO-1NC ABFD411N-➀AOFD411N-➀With Deep Shroud 2NO ABFD420N-➀AOFD420N-➀ 2NC ABFD402N-➀ AOFD402N-➀ www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-169 ø30mm - TWTD Series Oiltight Switches & Pilot Devices Non-Illuminated Pushbuttons (Sub-Assembled) Contact Block + Operator + Button + = Complete Part A4 Part Numbers: Operators Part Numbers: Buttons and Lenses Part Number Style Part Number Style Momentary Maintained Flush Flush/Extended ABD1BN-① ABD-100 AOD-100 Extended ABD2BN-① Extended with Full Shroud ABFD-200 AOFD-200 Ş 40mm Mushroom Ş 40mm Mushroom/ ABD3BN-① Ş 65mm Jumbo Mushroom ABD-300 AOD-300 Ş 65mm Jumbo Mushroom Ş 40mm Mushroom with ABD4BN-① Full Shroud ABGD-300 AOGD-300 In place of ①, specify the Button Color Code. (See table previous page) Ş 65mm Jumbo Mushroom with Shallow Shroud ABGD-400 AOGD-400 Part Numbers: Contact Blocks Description Part Number 1NO 1NC Ş 65mm Jumbo Mushroom with BST-010 BST-001 Deep Shroud BST-010S BST-001S ABFD-400 AOFD-400 (early make) (late break) Dummy Block BST-D 1. Dummy blocks (no contacts) are used with an odd num- ber of contact blocks. 2. Combining BST-010S and BST-001S result in overlap- ping contacts. A4-170 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø30mm - TWTD Series E-Stops (Assembled) A4 Assembled E-Stops AV (L) D 3 (99) 11 (D) N - R - (24V) Lamp Voltage Function (full voltage illuminated units only) V: Pushlock Turn Reset Y: Push-Pull 6V: 6V AC/DC 12V: 12V AC/DC Illumination 24V: 24V AC/DC Blank: None 120V: 120V AC/DC L: Illuminated 240V: 240V AC/DC Series Designation D: TWTD Series Button/Lens Color A: Amber R: Red W: White Button/Lens Size G: Green S: Blue Y: Yellow 3: 40mm Mushroom Lamp Type Illuminated Circuit (illuminated unit only) (illuminated units only) 99: Full Voltage (lamp determines voltage) Blank: Incandescent 126:120V AC Step Down Transformer D: LED 246: 240V AC Step Down Transformer 486: 480V AC Step Down Transformer Contact Arrangement 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO/1NC 22: 2NO/2NC 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Custom contact configurations available, contact IDEC for details. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-171 ø30mm - TWTD Series Oiltight Switches & Pilot Devices E-Stops (Assembled) Part Numbers: E-Stop Switches Style Contacts Part Number Ş 40mm Pushlock Turn 3 Position Push-Pull Reset 1NO AVD310N-R* Contact Push Center Pull A4 1NC AVD301N-R* 1NO-1NC AVD311N-R* NC Non-Illuminated 00 X 2NO AVD320N-R* (BST-001) 2NC AVD302N-R* NC-LB 0X X (BST-001S) NO Ş 40mm Illuminated X0 0 1NO-1NC AVLD39911➄N-R-➂* (BST-010) Pushlock Turn Reset 2NO AVLD39920➄N-R-➂* Full Voltage 2NC AVLD39902➄N-R-➂* NO-EM XX 0 (BST-010S) AVLD3 ➃ 11➄N-R* 1NO-1NC 1. In place of ➀, specify the button color code Transformer 2NO AVLD3 ➃ 20➄N-R* 2NC 2. In place of ➁, specify the lens color code. AVLD3 ➃ 02➄N-R* 3. In place of ➂, specify the Full Voltage (lamp Ş 40mm Push-Pull voltage) Code. 4. In place of ➃, specify the transformer voltage 1NO AYD310N-➀ 1NC AYD301N-➀code. Non-Illuminated 1NO-1NC AYD311N-➀ 5. In place of ➄, specify the Lamp Type code. 2NO AYD320N-➀ 6. *Available in red only. 2NC AYD302N-➀ 7. 3 position push-pull available in spring return to center only. 1NO-1NC AYLD39911➄N-➁-➂ ** 8. † The most common configuration for motor Ş 40mm Push-Pull Full Voltage 2NO AYLD39920➄N-➁-➂ ** starting applications. 2NC AYLD39902➄N-➁-➂ ** 9. For accessories, see page A4-188. 10. For dimensions, see page A4-192. AYLD3 ➃ 11➄N-➁ ** 1NO-1NC Transformer 2NO AYLD3 ➃ 20➄N-➁ ** 2NC AYLD3 ➃ 02➄N-➁** ➁ LED Color Codes① Button Color Code 1NO-1NC Color Code AYLD229911➄N-➁-➂ -TK962 Color Code Full Voltage Ş 40mm Momentary † AYLD229902S➄N-➁-➂-TK962 1NC-1LB Black B Amber A Push-Pull (3-position) Green G Green G Red R Red R 1NO-1NC AYLD22 ➃ 11➄N-➁-TK962 Blue S Blue S Transformer † AYLD22 ➃ 02S➄N-➁-TK962 1NC-1LB Yellow Y White W Part Numbers: Unibody E-Stops ➃ Transformer ➂ Full Voltage Code Voltage Codes Style Contacts Part Number Voltage Code Voltage Code 6V AC/DC 6V Ş 40mm Pushlock 120VAC 126 1NO-1NC HN1E-BV4F11-R* 12V AC/DC 12V Turn Reset 240VAC 246 2NC HN1E-BV4F02-R* (available in Red only) 480VAC 486 24V AC/DC 24V Transformers 120V AC 120V step down to 6V. Illuminated Ş 40mm 240V AC 240V (LED only) 1NO-1NC HN1E-LV4F11Q➄-R-➂ Pushlock Turn Reset 2NC HN1E-LV4F02Q➄-R-➂ (available in Red only) ➄ Lamp Type Code Lamp Code 1. * Available in Red only. Incandescent Blank 2. **Not available in blue. 3. In place of ➂, specify Full Voltage Code. LED D 4. With single unit construction, the positive action contacts are integrated in the body of the switch. This provides an extra degree of safety and reliability for critical emergency stop functions. 5. For nameplates and accessories, see page A3-96. 6. For dimensions, see page A3-100. 7. For sub-assembly part numbers, see next page. 8. HN1E series E-stops comply with EN418, the IEC “E-Stop Addendum to the Low Voltage Directive,” this includes “tamper proof” operation whereby a change of contact state is not possible by “teasing” or “floating” the operator. A4-172 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø30mm - TWTD Series E-Stops (Sub-Assembled) Transformer* + Operator + Lamp + Button/Lens = Complete Part A4 *Not required for full voltage units (full voltage clips used instead). Part Numbers: Operators Part Numbers: Lamps① Button Color Code Style Part Number Type Voltage Part Number Color Code 6V AC/DC LSTD-6➁Black B LED 12V AC/DC LSTD-1➁Green G Ş 40mm Pushlock AVD-300 Turn Reset 24V AC/DC LSTD-2➁Red R 120V AC LSTD-H2➁Blue S 240V AC LSTD-M4➁Yellow Y Illuminated 6V AC/DC IS-6 Incandescent Ş 40mm ➁ LED Color Codes AVLD3-0600N 12V AC/DC IS-12 Pushlock Turn Color Code Reset 24V AC/DC IS-24 Amber A 120VAC L-120L Green G 1. In place of ➁, specify the LED color Red R Ş 40mm Push-Pull AYD-3100 code. Blue S 2. The LED contains a current-limiting resistor and a protection diode. White W Part Numbers: Contact Blocks 2 pos AYLD-0600 Description Part Number Illuminated Ş 40mm Push-Pull All Control Units 1NO 1NC 3 pos AYLD22TK962-0B01 BST-010 BST-001 Part Numbers: Buttons and Lenses BST-010S BST-001S (early make) (late break) Style Part No. Dummy Blocks BST-D Button for Pushlock AVN3B-R Turn Reset E-Stop 1. Dummy blocks (no contacts) are used with an odd number of contact (Ş 40mm, red only) blocks. 2. Combining BST-010S and BST-001S result in overlapping contacts (remain on, or closed, when switch is moved between two positions). Lens for Illuminated Part Numbers: Full Voltage Clips Pushlock Turn AVLN3LU-R Primary Voltage (50/60Hz) Part Number Reset E-Stop (Ş 40mm, red only) Full Voltage Clips (2 req’d for each unit) APD-F Button for Push-Pull AYD3BN-① E-Stop (Ş 40mm) Part Numbers: Transformers Primary Voltage Part Description 2 pos* AYLD3L-➁(50/60Hz) Number Lens for Illuminated Push-Pull E-Stop 120V AC TWD-0126 (Ş 40mm) 3 pos AYLD2L-➁ 240V AC TWD-0246 1. In place of ①, specify the Button Color Code. (See table below) 480V AC TWD-0486 2. In place of ➁, specify the LED Color Code. 3. *Not available in blue. 6V secondary voltage (uses 6V lamp). www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-173 ø30mm - TWTD Series Oiltight Switches & Pilot Devices Pilot Lights (Assembled) A4 Assembled Pilot Lights APD1126 DN-R-() Function P: Pilot Light Lamp Voltage Series Designation (Full Voltage Only) D: TWTD Series 6V: 6V AC/DC Lens Shape 12V:12V AC/DC 1: Dome 24V:24V AC/DC 120V:120V AC Rated Operational Voltage (Primary) 240V: 240V AC (LED only) Transformer Type Full Voltage Type 126:120V AC 99:Full Voltage Lens Color Code 246:240V AC A: Amber 486:480V AC G: Green R: Red S: Blue W: White Y: Yellow Lamp Type Blank: Incandescent Lamp D: LED Lamp Use only when interpreting part numbers. Do not use for developing part numbers. Part Numbers: LED and Incandescent Pilot Lights ➁ Lens Color Code Style Operating Voltage Part Number Color Code Transformer Dome LED Incandescent Amber A Green G 120V AC APD1126DN-➁APD1126N-➁ 240V AC APD1246DN-➁APD1246N-➁Red R 480V AC APD1486DN-➁APD1486N-➁ Blue S Full Voltage Dome White W Yellow Y — APD199DN-➁-➂APD199N-➁-➂ 1. In place of ➁, specify the Lens/LED Color Code.➂ Full Voltage Code 2. In place of ➂, specify the Full Voltage Code (lamp voltage). Voltage Code 6V AC/DC 6V 12V AC/DC 12V 24V AC/DC 24V 120V AC 120V 240V AC (LED only) 240V A4-174 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø30mm - TWTD Series Pilot Lights (Sub-Assembled) Transformer* + Operator + Lamp + Lens = Complete Part A4 Note: Not required for full voltage units (full voltage clips used instead). Part Numbers: Operators Part Numbers: Full Voltage Clips Style Part Number Primary Voltage (50/60Hz) Part Number Full Voltage APD-F APD-199 Required for all full voltage models. Two pieces each. AC Adaptor/Transformer Part Numbers: Transformers APD-006 Primary Voltage Part Description (50/60Hz) Number Transformers 120V AC TWD-0126 The lens, lamp, and transformer/adaptor or the full voltage clips must be ordered separately. 240V AC TWD-0246 Part Numbers: Lenses 480V AC TWD-0486 Style Part Number Dome Lens 6V secondary voltage (use 6V lamp). APN106L-➁ ➁ Lens/LED Color Code 1. In place of ➁, specify the Lens Color Code. Color Code 2. LED and incandescent lenses differ in shade only. Some colors have only one shade. Amber A Green G Red R Part Numbers: Lamps Blue S Type Voltage Part Number White W 6V AC/DC LSTD-6➁ LED Yellow Y 12V AC/DC LSTD-1➁ 24V AC/DC LSTD-2➁ 120V AC LSTD-H2➁ 240V AC LSTD-M4➁ 6.3V AC/DC IS-6 Incandescent 12V AC/DC IS-12 24V AC/DC IS-24 120VAC, 1-8W L-120L 1. In place of ➁, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-175 ø30mm - TWTD Series Oiltight Switches & Pilot Devices Illuminated Pushbuttons (Assembled) A4 Assembled Illuminated Pushbuttons AL()D2126 11 (D)N-R-() Function L: Momentary Action OL: Alternate Action Lamp Voltage Bezel Shape (Full Voltage Only) Blank: Octagonal 6V: 6V AC/DC F: Full Shroud 12V: 12V AC/DC 24V: 24V AC/DC Series Designation 120V:120V AC D: TWTD Series 240V: 240V AC (LED only) Lens Shape 2: Extended Lens Color Code 3: Mushroom Ø 40mm A: Amber Rated Operational Voltage (Primary) G: Green Transformer Full Voltage Type R: Red 126:120V AC 99:Full Voltage S: Blue 246:240V AC W: White 486:480V AC Y: Yellow Lamp Type Blank: Incandescent Lamp D: LED Contact Arrangement 20: 2NO 02: 2NC 11: 1NO-1NC 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. All transformers and AC Adaptors step down to 6V. A4-176 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø30mm - TWTD Series Illuminated Pushbuttons (Assembled) con’t Part numbers: Illuminated Pushbuttons Style Part Number Contacts Momentary Maintained A4 1NO-1NC ALD29911➄N-➁-➂ AOLD29911➄N-➁-➂ Extended Lens 2NO ALD29920➄N-➁-➂AOLD29920➄N-➁-➂Full Voltage 2NC ALD29902➄N-➁-➂AOLD29902➄N-➁-➂ 1NO-1NC ALD2 ➃ 11➄N-➁AOLD2 ➃ 11➄N-➁ 2NO ALD2 ➃ 20➄N-➁AOLD2 ➃ 20➄N-➁Transformer 2NC ALD2 ➃ 02➄N-➁AOLD2 ➃ 02➄N-➁ 1NO-1NC ALFD29911➄N-➁-➂ AOLFD29911➄N-➁-➂ Extended Lens with Full Shroud 2NO ALFD29920➄N-➁-➂AOLFD29920➄N-➁ ➂Full Voltage 2NC ALFD29902➄N-➁-➂AOLFD29902➄N-➁-➂ 1NO-1NC ALFD2 ➃ 11➄N-➁AOLFD2 ➃ 11➄N-➁ 2NO ALFD2 ➃ 20➄N-➁AOLFD2 ➃ 20➄N-➁Transformer 2NC ALFD2 ➃ 02➄N-➁ AOLFD2 ➃ 02➄N-➁ 1NO-1NC ALD39911➄N-➁-➂AOLD39911➄N-➁-➂ Ş 40mm Mushroom Lens 2NO ALD39920➄N-➁-➂AOLD39920➄N-➁-➂Full Voltage 2NC ALD39902➄N-➁-➂AOLD39902➄N-➁-➂ 1NO-1NC ALD3 ➃ 11➄N-➁AOLD3 ➃ 11➄N-➁ 2NO ALD3 ➃ 20➄N-➁AOLD3 ➃ 20➄N-➁Transformer 2NC ALD3 ➃ 02➄N-➁AOLD3 ➃ 02➄N-➁ 1. In place of ➁, specify the Lens Color Code. 2. In place of ➂, specify the Full Voltage Code (lamp voltage). 3. In place of ➃, specify the Transformer Voltage Code. 4. In place of ➄, specify the Lamp Type Code. ➁ Lens Color Codes ➂ Full Voltage Codes ➃ Transformer Voltage Codes Color Code Voltage Code Voltage Code 120VAC 126 Amber A 6V AC/DC 6V 240VAC 246 Green G 12V AC/DC 12V 480VAC 486 Red R 24V AC/DC 24V 6V secondary voltage (uses 6V lamp). Blue S 120V AC 120V White W 240V AC (LED only) 240 V Yellow Y ➄ Lamp Type Code Lamp Code Incandescent Blank LED D www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-177 ø30mm - TWTD Series Oiltight Switches & Pilot Devices Illuminated Pushbuttons (Sub-Assembled) Transformer* + Contact Block + Operator + Lamp + Lens = Complete Part A4 * Not required for full voltage types (full voltage types use APD-F full voltage clips). Part Numbers: Operators ➁ Lens/LED Color Codes Part Numbers: Lamps Part Number Color Code Type Voltage Part Number Style Momentary Maintained Amber A 6V AC/DC LSTD-6➁ LED Extended Green G 12V AC/DC LSTD-1➁ Red R 24V AC/DC LSTD-2➁ ALD-0600 AOLD-0600 Blue S 120V AC LSTD-H2➁ White W 240V AC LSTD-M4➁ Yellow Y 6V AC/DC IS-6 Incandescent Extended with Full Shroud Mushroom lens not 12V AC/DC IS-12 available in yellow. 24V AC/DC IS-24 ALFD-0600 AOLFD-0600 120VAC L-120L 1. In place of ➁, specify the LED Color 40mm Mushroom code. 2. The LED contains a current-limiting resistor and a protection diode. ALD-0600 AOLD-0600 Part Numbers: Contact Blocks Description Part Number Part Numbers: Lenses All Control Units 1NO 1NC Style Part No. Extended BST-010 BST-001 ALN06LU-➁BST-010S BST-001S (early make) (late break) Ş 40mm Mushroom Dummy Blocks BST-D 1. Dummy blocks (no contacts) are used with an odd ALN3LU-➁number of contact blocks. 2. Combining BST-010S and BST-001S result in over- lapping contacts (remain on, or closed, when switch is moved between two positions). 1. In place of ➁, specify the Lens Color Code. 2. LED and incandescent lenses differ in shade only. Some colors have only one shade. Part Numbers: Transformers Primary Voltage Part Description Part Numbers: Full Voltage Clips (50/60Hz) Number Primary Voltage (50/60Hz) Part Number Transformers 120V AC TWD-0126 Full Voltage Clips (2 req’d for each unit) APD-F 240V AC TWD-0246 Required for all full voltage models. 480V AC TWD-0486 6V secondary voltage (uses 6V lamp). A4-178 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø30mm - TWTD Series Non-Illuminated Selector Switches (Assembled) A4 Knob Selector Key Selector Lever Selector (Non-illuminated) (Non-illuminated) (Non-illuminated) Assembled Selector Switches AS D2 ()()11 N -() Function Circuit Number S: Selector Switch (See Circuit # column of Selector Switch Contact Arrangement Chart on beginning on A4-185.) Series Designation Contact Arrangement Code D: TWTD Series 10: 1NO 01: 1NC Number of Positions 20: 2NO 02: 2NC 2: 2-Position 40: 4NO 04: 4NC 3: 3-Position 11: 1NO-1NC 22: 2NO-2NC Spring Return Action Operator Style Code Blank: Maintained Blank: Knob Operator 1: Spring return from Right L: Lever Operator 2: Spring return from Left K: Key Operator 3: 2-Way spring return from Left and Right Use only when interpreting part numbers. Do not use for developing part numbers. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-179 ø30mm - TWTD Series Oiltight Switches & Pilot Devices Non-Illuminated Selector Switches (Assembled) con’t Part numbers: Non-Illuminated 2–Position Selector Switches Style Part Number Part Number Part Number Operator Position Spring Return from Right Spring Return from Left Maintained L R L L A4 R R LR Knob ASD210N ASD2110N ASD2210N 1 O X Lever ASD2L10N ASD21L10N ASD22L10N 1NO 2 O O Key ASD2K10N ASD21K10N ASD22K10N Knob ASD201N-116 ASD2101N-116 ASD2201N-116 1 X O Lever ASD2L01N-116 ASD21L01N-116 ASD22L01N-116 1NC 2 O O Key ASD2K01N-116 ASD21K01N-116 ASD22K01N-116 Knob ASD211N ASD2111N ASD2211N 1NO 1 O X Lever ASD2L11N ASD21L11N ASD22L11N 2 X O 1NC Key ASD2K11N ASD21K11N ASD22K11N Knob ASD220N ASD2120N ASD2220N 1 O X Lever ASD2L20N ASD21L20N ASD22L20N 2NO 2 O X Key ASD2K20N ASD21K20N ASD22K20N Knob ASD202N-104 ASD2102N-104 ASD2202N-104 1 X O Lever ASD2L02N-104 ASD21L02N-104 ASD22L02N-104 2NC 2 X O Key ASD2K02N-104 ASD21K02N-104 ASD22K02N-104 1 O X Knob ASD222N ASD2122N ASD2222N 2NO 2 X O Lever ASD2L22N ASD21L22N ASD22L22N 3 O X 2NC Key ASD2K22N ASD21K22N ASD22K22N 4 X O 1 O X Knob ASD222N-111 ASD2122N-111 ASD2222N-111 2NO 2 O X Lever ASD2L22N-111 ASD21L22N-111 ASD22L22N-111 3 X O 2NC Key ASD2K22N-111 ASD21K22N-111 ASD22K22N-111 4 X O Part Numbers: Non-Illuminated 3–Position Selector Switches Style Part Number Part Number Part Number Part Number Operator Position Maintained Spring Return from Right Spring Return From Left Spring Return Two-Way C C C C L L LC R L L R R R R Knob ASD320N ASD3120N ASD3220N ASD3320N 1 X O O Lever ASD3L20N ASD31L20N ASD32L20N ASD33L20N 2NO 2 O O X Key ASD3K20N ASD31K20N ASD32K20N ASD33K20N Knob ASD302N ASD3102N ASD3202N ASD3302N 1 O X X Lever ASD3L02N ASD31L02N ASD32L02N ASD33L02N 2NC 2 X X O Key ASD3K02N ASD31K02N ASD32K02N ASD33K02N 1 X O O Knob ASD322N ASD3122N ASD3222N ASD3322N 2NO 2 O O X Lever ASD3L22N ASD31L22N ASD32L22N ASD33L22N 3 O X X 2NC Key ASD3K22N ASD31K22N ASD32K22N ASD33K22N 4 X X O 1 X O X Knob ASD322N-309 ASD3122N-309 ASD3222N-309 ASD3322N-309 2NO 2 X X O Lever ASD3L22N-309 ASD31L22N-309 ASD32L22N-309 ASD33L22N-309 3 O X O 2NC Key ASD3K22N-309 ASD31K22N-309 ASD32K22N-309 ASD33K22N-309 4 O O X 1 O X O Knob ASD322N-310 ASD3122N-310 ASD3222N-310 ASD3322N-310 2NO 2 O O X Lever ASD3L22N-310 ASD31L22N-310 ASD32L22N-310 ASD33L22N-310 3 O X O 2NC Key ASD3K22N-310 ASD31K22N-310 ASD32K22N-310 ASD33K22N-310 4 O O X 1 X O O Knob ASD340N ASD3140N ASD3240N ASD3340N 2 O O X Lever ASD3L40N ASD31L40N ASD32L40N ASD33L40N 4NO 3 X O O Key ASD3K40N ASD31K40N ASD32K40N ASD33K40N 4 O O X 1 O X X Knob ASD304N ASD3104N ASD3204N ASD3304N 2 X X O Lever ASD3L04N ASD31L04N ASD32L04N ASD33L04N 4NC 3 O X X Key ASD3K04N ASD31K04N ASD32K04N ASD33K04N 4 X X O 1. The truth table indicates the operating position of contact block when the operator is switched to that position. X = On (closed contacts) O = Off (open contacts) X X = Overlapping Contacts: Remain on (closed contacts) when switch is moved between these two positions. 2. All knob and lever selector switches come in black. Other colors are available by ordering the knob or lever separately. 3. Custom contact arrangements available, see page A4-185 or call IDEC for details. A4-180 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Contact Contact Mounting Mounting Switches & Pilot Devices Oiltight Switches & Pilot Devices ø30mm - TWTD Series Non-Illuminated Selector Switches (Sub-Assembled) Contact Blocks + Operator + Knob or Lever* + Color Insert* = Complete Part † A4 1. * Not needed with key type switches. 2. † Knob type shown. Part Numbers: Operators Part Numbers: Handles and Inserts Appearance/ Part Style Part Number Description Position Number Knob 2 Maintained ASD200 ASDHHY - ①Spring-Ret. from Right ASD2100 2 Knob & Lever Spring-Ret. from Left ASD2200 Maintained, Cam 1 ASD300-1 3 Maintained, Cam 2 ASD300-2 Lever Spring-Ret. from Right, Cam1 ASD3100-1 Spring-Ret. from Right, Cam 2 ASD3100-2 ASDHHL -① Spring-Ret. from Left, Cam 1 ASD3200-1 3 Spring-Ret. from Left, Cam 2 ASD3200-2 Spring-Ret. from L/R, Cam 1 ASD3300-1 Spring-Ret. from L/R, Cam 2 ASD3300-2 Color Insert 2 Maintained ASD2K00-RA Spring-Ret. from Right ASD21K00-RL 2 TW-HC1 - ① Key Spring-Ret. from Left ASD22K00 Maintained, Cam 1 ASD3K00-1-RA 3 Maintained, Cam 2 ASD3K00-2-RA Spring-Ret. from Right, Cam1 ASD31K00-1-RLC In place of ①, specify the Color Code. Spring-Ret. from Right, Cam 2 ASD31K00-2-RLC Spring-Ret. from Left, Cam 1 ASD32K00-1-RRC 3 Spring-Ret. from Left, Cam 2 ASD32K00-2-RRC Spring-Ret. from L/R, Cam 1 ASD33K00-1-RC Part Numbers: Contact Blocks Spring-Ret. from L/R, Cam 2 ASD33K00-2-RC Style Part Number 1. Order knobs, levers, color inserts separately (see below). 1NO 1NC 2. For key switches, keys are removable in all maintained posi- tions. Other options available, contact IDEC for details. 3. See page A4-187 “Operator Truth Tables” for details of differ- BST-010 BST-001 ence between cams. BST-010S (early BST-001S (late make) break) ① Color Codes Knob/Lever Color Code BST-D Black B Dummy Blocks Blue S 1. Dummy blocks (no contacts) are used with an odd number of con- Green G tact blocks. Red R 2. Combining BST-010S and BST-001S result in overlapping contacts Yellow Y (remain on, or closed, when switch is moved between two posi- White W tions). 1. Knob/Lever not available in white. 2. Color inserts not available in Black. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-181 ø30mm - TWTD Series Oiltight Switches & Pilot Devices Illuminated Selector Switches (Assembled) A4 Assembled Illuminated Selector Switches ASL D 2 (2) 126 11 D N - 111 - R - 24 Lamp Voltage Function (Full Voltage Only) SL: Illuminated Selector Switch 6V: 6V AC/DC Series Designation 12V:12V AC/DC D: TWTD Series 24V:24V AC/DC Number of Positions 120V:120V AC 2: 2-Position 240V: 240V AC (LED only) 3: 3-Position Spring Return Action Lens Color Code Blank: Maintained A: Amber 1: Spring return from Right G: Green 2: Spring return from Left R: Red 3: 2-Way spring return from Left and Right S: Blue Rated Operational Voltage (Primary) W: White Transformer Full Voltage Type Y: Yellow 126:120V AC 99: Full Voltage Circuit Code Number 246:240V AC See Circuit # column of Selector Switch 486:480V AC Contact Arrangement Charts on page A4-185. Contact Arrangement Lamp Type 20: 2NO 02: 2NC Blank: Incandescent 40: 4NO 04: 4NC D: LED 11: 1NO-1NC 22: 2NO-2NC Use only when interpreting part numbers. Do not use for developing part numbers. A4-182 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø30mm - TWTD Series Illuminated Selector Switches (Assembled) con’t Part Numbers: Illuminated 2–Position Selector Switches➁ Lens/LED Color Codes Style Color Code Operator Spring Return Spring Return Amber A Maintained Green G Position From Right From Left A4 Red R L R L L Blue S LR R R White W Yellow Y 1NO 1 O X transformer ASLD2 ➃11➄N-➁ASLD21 ➃11➄N-➁ASLD22 ➃11➄N-➁ 2 X O full voltage ASLD29911➄N-➁-➂ASLD219911➄N-➁-➂ ASLD229911➄N-➁-➂1NC➂ Full Voltage Codes 1 O X transformer ASLD2 ➃20➄N-➁ASLD21 ➃20➄N-➁ASLD22 ➃20➄N-➁Voltage Code 2NO 2 O X full voltage ASLD29920➄N-➁-➂ASLD219920➄N-➁-➂ASLD229920➄N-➁-➂ 6V AC/DC 6V 1 X O transformer ASLD2 ➃02➄N-104-➁ASLD21 ➃02➄N-104-➁ASLD22 ➃02➄N-104-➁12V AC/DC 12V 2NC 2 X O full voltage ASLD29902➄N-104-➁-➂ASLD219902➄N-104-➁-➂ASLD229902➄N-104-➁-➂ 24V AC/DC 24V 1 O X 120V AC 120V 2NO 2 X O transformer ASLD2 ➃22➄N-➁ASLD21 ➃22➄N-➁ASLD22 ➃22➄N-➁ 240V AC (LED only) 240V 3 O X full voltage 2NC ASLD29922➄N-➁- ➂ASLD219922➄N-➁-➂ASLD229922➄N-➁-➂ 4 X O➃Transformer Voltage Codes 1 O X 2NO 2 O X transformer ASLD2 ➃22➄N-11-➁ASLD21 ➃22➄N-111-➁ASLD22 ➃22➄N-111-➁ Voltage Code 3 X O full voltage 2NC ASLD29922➄N-111-➁-➂ASLD219922➄N-111-➁-➂ASLD229922➄N-111-➁-➂ 4 X O 120VAC 126 240VAC 246 480VAC 486 ➄ Lamp Type Code Lamp Code 6V secondary voltage (uses 6V lamps). Incandescent Blank LED D Part Numbers: Illuminated 3–Position Selector Switches Style Operator Spring Return From Maintained Spring Return From Left Spring Return Two-Way Position Right C C C C L L L R R R LC R L R 1 X O O transformer ASLD3 ➃ 20➄N-➁ASLD31 ➃ 20➄N-➁ASLD32 ➃ 20D➄N-➁ASLD33 ➃ 20D➄N-➁ 2NO 2 O O X full voltage ASLD39920➄N-➁-➂ASLD319920➄N-➁- ➂ASLD329920D➄N-➁-➂ASLD339920D➄N-➁-➂ 1 O X X transformer ASLD3 ➃ 02➄N-➁ASLD31 ➃ 02➄N-➁ASLD32 ➃ 02D➄N-➁ASLD33 ➃ 02D➄N-➁ 2NC 2 X X O full voltage ASLD39902➄N-➁-➂ASLD319902➄N-➁-➂ASLD329902D➄N-➁-➂ASLD339902D➄N-➁-➂ 1 X O O 2NO 2 O O X transformer ASLD3 ➃ 22➄N-➁ASLD31 ➃ 22➄N-➁ASLD32 ➃ 22D➄N-➁ASLD33 ➃ 22D➄N-➁ 3 O X X full voltage ASLD39922➄N-➁-➂ASLD319922➄N-➁-➂ASLD329922D➄N-➁-➂ASLD339922D➄N-➁-➂2NC 4 X X O 1 X O X 2NO 2 X X O transformer ASLD3 ➃ 22➄N-309-➁ASLD31 ➃ 22➄N-309-➁ASLD32 ➃ 22D➄N-309-➁ASLD33 ➃ 22D➄N-309-➁ 3 O X O full voltage ASLD39922➄N-309-➁-➂ASLD319922➄N-309-➁-➂ASLD329922D➄N-309-➁-➂ASLD339922D➄N-309-➁-➂2NC 4 O O X 1 O X O 2NO 2 O O X transformer ASLD3 ➃ 22➄N-310-➁ASLD31 ➃ 22➄N-310-➁ASLD32 ➃ 22D➄N-310-➁ASLD33 ➃ 22D➄N-310-➁ 3 O X O full voltage ASLD39922➄N-310-➁-➂ASLD319922➄N-310-➁-➂ASLD329922D➄N-310-➁-➂ASLD339922D➄N-310-➁-➂2NC 4 O O X 1 X O O 2 O O X transformer ASLD3 ➃ 40➄N-➁ASLD31 ➃ 40➄N-➁ASLD32 ➃ 40➄N-➁ASLD33 ➃ 40➄N-➁ 4NO 3 X O O full voltage ASLD39940➄N-➁-➂ASLD319940➄N-➁-➂ASLD329940➄N-➁-➂ASLD339940➄N-➁-➂ 4 O O X 1 O X X 2 X X O transformer ASLD3 ➃ 04➄N-➁ASLD31 ➃ 04➄N-➁ASLD32 ➃ 04➄N-➁ASLD33 ➃ 04➄N-➁ 4NC 3 O X X full voltage ASLD39904➄N-➁-➂ASLD319904➄N-➁-➂ASLD329904➄N-➁-➂ASLD339904➄N-➁-➂ 4 X X O 1. In place of ➁, specify the Lens/LED Color Code, in place of ➂, specify the Full Voltage (lamp voltage) Code, in place of ➃, specify the Trans- former Voltage Code and in place of ➄ specify the Lamp Type Code. 2. The truth table indicates the operating position of contact block when the operator is switched to that position. X = On (Closed Contacts) O = Off (Open Contacts) X X = Overlapping Contacts: Remain on (closed contacts) when switch is moved between these positions www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-183 Contact Contact Mounting Mounting ø30mm - TWTD Series Oiltight Switches & Pilot Devices Illuminated Selector Switches (Sub-Assembled) Transformer* + Contact Block + Operator + Lamp Lense = Complete Part A4 *Not required for full voltage units (use APD-F full voltage clips instead). Part Numbers: Operators Contact Blocks Appearance/ Part Description Part Number Description Positions Number 1NO 1NC 2 Maintained ASLD200 Maintained, Cam 1 ASLD300-1 3 Maintained, Cam 2 ASLD300-2 Operator Spring-Ret. from Right ASLD2100 BST-010 BST-001 2 Spring-Ret. from Left ASLD2200 BST-010S BST-001S Spring-Ret. from Right, Cam 1 ASLD3100-1 (early make) (late break) Spring-Ret. from Right, Cam 2 ASLD3100-2 Spring-Ret. from Left, Cam 1 ASLD3200-1 3 Spring-Ret. from Left, Cam 2 ASLD3200-2 Spring-Ret. from L/R, Cam 1 ASLD3300-1 Dummy Blocks BST-D Spring-Ret. from L/R, Cam 2 ASLD3300-2 1. Dummy blocks (no contacts) are used with an odd number of Part Numbers: Lenses contact blocks. 2. Combining BST-010S and BST-001S result in overlapping contacts Style Part Number (make before break). Knob ASLNHU - ➀ Part Numbers: Full Voltage Clips Primary Voltage (50/60Hz) Part Number Full Voltage Clips APD-F Part Numbers: Lamps (2 req’d for each unit) Type Voltage Part Number 6V AC/DC LSTD-6➁ Part Numbers: Transformers LED 12V AC/DC LSTD-1➁ Primary Voltage Part Description (50/60Hz) Number 24V AC/DC LSTD-2➁ 120V AC LSTD-H2➁ Transformers 120V AC TWD-0126 240V AC LSTD-M4➁ 6.3V AC/DC IS-6 Incandescent 12V AC/DC IS-12 240V AC TWD-0246 24V AC/DC IS-24 120VAC L-120L 480V AC TWD-0486 1. In place of ➁, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. 6V secondary voltage ➁ Lens/LED Color Codes Color Code Amber A Green G Red R Blue S White W Yellow Y A4-184 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø30mm - TWTD Series Contact Arrangement Charts How to Read Contact Arrangement Charts To determine contact block mounting position, first make sure the selector switch is oriented as shown on the right Contact Arrangement 4 R A4 Type and quantity of L 2 switch contacts Circuit Number Operator Position * N/D = No designation Truth table indicates the operating position of contact block when opera- Contact Block Mounting tor is switched to that position. 3 Position or mounting contact 1 blocks on operator X = On (Closed Contacts) O = Off (Open Contacts) X X = Overlapping Contacts: Remain on (closed) when switch is moved between these two positions Contact Block Part Number Part number to use when ordering sub- assembly contact blocks, as required for use with corresponding mounting position Contact Arrangement Chart: 2-position Selector Switches Style Operator Part Number Mounting Operator Contact Block Description Circuit Spring Ret. Spring Ret. Position Position Part Number Contact Maintained Number from Rt. from Lt. LR R L R L L R Knob/Lever ASD200 ASD2100 ASD2200 1O X BST-010 Key ASD2K00 ASD21K00 ASD22K00 1NO N/D 2O O BST-D Illuminated Knob ASLD200 ASLD2100 ASLD2200 Knob/Lever ASD200 ASD2100 ASD2200 1X O BST-001 1NC 116 Key ASD2K00 ASD21K00 ASD22K00 2O O BST-D Illuminated Knob ASLD200 ASLD2100 ASLD2200 Knob/Lever ASD200 ASD2100 ASD2200 1O X BST-010 N/D Key ASD2K00 ASD21K00 ASD22K00 2X O BST-001 Illuminated Knob ASLD200 ASLD2100 ASLD2200 1NO 1NC Knob/Lever ASD200 ASD2100 ASD2200 1X O BST-001 103 Key ASD2K00 ASD21K00 ASD22K00 2O X BST-010 Illuminated Knob ASLD200 ASLD2100 ASLD2200 1O X BST-010S Knob/Lever ASD200 ASD2100 ASD2200 600 Key ASD2K00 ASD21K00 ASD22K00 2X O BST-001S Illuminated Knob ASLD200 ASLD2100 ASLD2200 1NO-EM 1NC-LB Knob/Lever ASD200 ASD2100 ASD2200 1X O BST-001S Key ASD2K00 ASD21K00 ASD22K00 601 2O X BST-010S Illuminated Knob ASLD200 ASLD2100 ASLD2200 Knob/Lever ASD200 ASD2100 ASD2200 1O X BST-010 2NO N/D Key ASD2K00 ASD21K00 ASD22K00 2O X BST-010 Illuminated Knob ASLD200 ASLD2100 ASLD2200 Knob/Lever ASD200 ASD2100 ASD2200 1X O BST-001 2NC 104 Key ASD2K00 ASD21K00 ASD22K00 2X O BST-001 Illuminated Knob ASLD200 ASLD2100 ASLD2200 1O X BST-010 Knob/Lever ASD200 ASD2100 ASD2200 2X O BST-001 Key ASD2K00 ASD21K00 ASD22K00 N/D 3O X BST-010 Illuminated Knob ASLD200 ASLD2100 ASLD2200 4X O BST-001 1X O BST-001 Knob/Lever ASD200 ASD2100 ASD2200 2O X BST-010 2NO Key ASD2K00 ASD21K00 ASD22K00 110 3X O BST-001 2NC Illuminated Knob ASLD200 ASLD2100 ASLD2200 4O X BST-010 1O X BST-010 Knob/Lever ASD200 ASD2100 ASD2200 2O X BST-010 Key ASD2K00 ASD21K00 ASD22K00 111 3X O BST-001 Illuminated Knob ASLD200 ASLD2100 ASLD2200 4X O BST-001 1O X BST-010 Knob/Lever ASD200 ASD2100 ASD2200 2O X BST-010 Key ASD2K00 ASD21K00 ASD22K00 4NO N/D 3O X BST-010 Illuminated Knob ASLD200 ASLD2100 ASLD2200 4O X BST-010 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-185 ø30mm - TWTD Series Oiltight Switches & Pilot Devices Contact Arrangement Chart: 3-Position Selector Switches Style Operator Part Number Mounting Operator Contact Block Circuit Description Spring Ret. Spring Ret. Contact Position Position Part Number Maintained Two-Way Number from Rt. from Lt. L C R C C C C L R L L R R L R Knob/Lever ASD300-1 ASD3100-1 ASD3200-1 ASD3300-1 1X 00 BST-010 A4 202 Key ASD3K00-1 ASD31K00-1 ASD32K00-1 ASD33K00-1 2X XO BST-001 Illuminated Knob ASLD300-1 ASLD3100-1 ASLD3200-1 ASLD3300-1 Knob/Lever ASD300-1 ASD3100-1 ASD3200-1 ASD3300-1 10 XX BST-001 203 Key ASD3K00-1 ASD31K00-1 ASD32K00-1 ASD33K00-1 2O 0X BST-010 Illuminated Knob ASLD300-1 ASLD3100-1 ASLD3200-1 ASLD3300-1 1NO 1NC Knob/Lever ASD300-2 ASD3100-2 ASD3200-2 ASD3300-2 1 X0X BST-010 302 Key ASD3K00-2 ASD31K00-2 ASD32K00-2 ASD33K00-2 2X XO BST-001 Illuminated Knob ASLD300-2 ASLD3100-2 ASLD3200-2 ASLD3300-2 10 XO BST-001 Knob/Lever ASD300-2 ASD3100-2 ASD3200-2 ASD3300-2 303 Key ASD3K00-2 ASD31K00-2 ASD32K00-2 ASD33K00-2 2O 0X BST-010 Illuminated Knob ASLD300-2 ASLD3100-2 ASLD3200-2 ASLD3300-2 Knob/Lever ASD300-1 ASD3100-1 ASD3200-1 ASD3300-1 1X 00 BST-010 Key ASD3K00-1 ASD31K00-1 ASD32K00-1 ASD33K00-1 N/D 2O 0X BST-010 Illuminated Knob ASLD300-1 ASLD3100-1 ASLD3200-1 ASLD3300-1 2NO Knob/Lever ASD300-2 ASD3100-2 ASD3200-2 ASD3300-2 1 X0X BST-010 301 Key ASD3K00-2 ASD31K00-2 ASD32K00-2 ASD33K00-2 2O 0X BST-010 Illuminated Knob ASLD300-2 ASLD3100-2 ASLD3200-2 ASLD3300-2 Knob/Lever ASD300-2 ASD3100-2 ASD3200-2 ASD3300-2 10 XO BST-001 304 Key ASD3K00-2 ASD31K00-2 ASD32K00-2 ASD33K00-2 2X XO BST-001 Illuminated Knob ASLD300-2 ASLD3100-2 ASLD3200-2 ASLD3300-2 2NC Knob/Lever ASD300-1 ASD3100-1 ASD3200-1 ASD3300-1 10 XX BST-001 N/D Key ASD3K00-1 ASD31K00-1 ASD32K00-1 ASD33K00-1 2X XO BST-001 Illuminated Knob ASLD300-1 ASLD3100-1 ASLD3200-1 ASLD3300-1 1X 00 BST-010 Knob/Lever ASD300-1 ASD3100-1 ASD3200-1 ASD3300-1 20 0X BST-010 N/D Key ASD3K00-1 ASD31K00-1 ASD32K00-1 ASD33K00-1 30 XX BST-001 Illuminated Knob ASLD300-1 ASLD3100-1 ASLD3200-1 ASLD3300-1 4X X0 BST-001 10 XX BST-001 Knob/Lever ASD300-1 ASD3100-1 ASD3200-1 ASD3300-1 20 0X BST-010 210 Key ASD3K00-1 ASD31K00-1 ASD32K00-1 ASD33K00-1 30 XX BST-001 Illuminated Knob ASLD300-1 ASLD3100-1 ASLD3200-1 ASLD3300-1 40 0X BST-010 1 X0X BST-010 Knob/Lever ASD300-2 ASD3100-2 ASD3200-2 ASD3300-2 2NO 2X X0 BST-001 308 Key ASD3K00-2 ASD31K00-2 ASD32K00-2 ASD33K00-2 2NC 3 X0X BST-010 Illuminated Knob ASLD300-2 ASLD3100-2 ASLD3200-2 ASLD3300-2 4X XO BST-001 1 X0X BST-010 Knob/Lever ASD300-2 ASD3100-2 ASD3200-2 ASD3300-2 2X X0 BST-001 309 Key ASD3K00-2 ASD31K00-2 ASD32K00-2 ASD33K00-2 30 XO BST-001 Illuminated Knob ASLD300-2 ASLD3100-2 ASLD3200-2 ASLD3300-2 4O 0X BST-010 10 XO BST-001 Knob/Lever ASD300-2 ASD3100-2 ASD3200-2 ASD3300-2 2O 0X BST-010 310 Key ASD3K00-2 ASD31K00-2 ASD32K00-2 ASD33K00-2 30 XO BST-001 Illuminated Knob ASLD300-2 ASLD3100-2 ASLD3200-2 ASLD3300-2 40 0X BST-010 1X 00 BST-010 Knob/Lever ASD300-1 ASD3100-1 ASD3200-1 ASD3300-1 20 0X BST-010 N/D Key ASD3K00-1 ASD31K00-1 ASD32K00-1 ASD33K00-1 3X 00 BST-010 Illuminated Knob ASLD300-1 ASLD3100-1 ASLD3200-1 ASLD3300-1 40 0X BST-010 4NO 1 X0X BST-010 Knob/Lever ASD300-2 ASD3100-2 ASD3200-2 ASD3300-2 20 0X BST-010 305 Key ASD3K00-2 ASD31K00-2 ASD32K00-2 ASD33K00-2 3 X0X BST-010 Illuminated Knob ASLD300-2 ASLD3100-2 ASLD3200-2 ASLD3300-2 40 0X BST-010 10 XX BST-001 Knob/Lever ASD300-1 ASD3100-1 ASD3200-1 ASD3300-1 2X X0 BST-001 N/D Key ASD3K00-1 ASD31K00-1 ASD32K00-1 ASD33K00-1 30 XX BST-001 Illuminated Knob ASLD300-1 ASLD3100-1 ASLD3200-1 ASLD3300-1 4X XO BST-001 4NC 10 XO BST-001 Knob/Lever ASD300-2 ASD3100-2 ASD3200-2 ASD3300-2 2X X0 BST-001 314 Key ASD3K00-2 ASD31K00-2 ASD32K00-2 ASD33K00-2 30 XO BST-001 Illuminated Knob ASLD300-2 ASLD3100-2 ASLD3200-2 ASLD3300-2 4X X0 BST-001 1. Each operator sub-assembly is available as a “-1" and a “-2" for 3-position selector switches. The internal cam of a “-1" is different from that of a “-2". This results in designated combinations of open and closed contacts in the various operator positions. 2. N/D = No circuit number designation required in assembled part number. 3. X = On (closed contacts) O = Off (open contacts). X X Overlapping contacts remain on (closed) when switch is moved between these two positions. A4-186 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Switches & Pilot Devices ø30mm - TWTD Series Operator Truth Tables Use the following tables to build custom selector switches. 2 Position Selector Switches Operator Mounting Position A4 Contact Position Left Right LO X BST-010 (NO) RO X LX O BST-001 (NC) RX O ASD200 L0 X BST-010S (NO-EM) RO X LX O BST-001S (NC-LB) RX O 3 Position Selector Switches Operator Position Mounting Contact Position Left Center Right LX O O BST-010 (NO) RO O X LO X X BST-001 (NC) ASD300-1 RX X O ASLD300-1 LX O O ASD3K00-1 BST-010S (NO-EM) RO O X LO X X BST-001S (NC-LB) RX X O Operator Position Mounting Contact Position Left Center Right L XOX BST-010 (NO) RO O X 1. For Operator Truth Tables, see L OXO next page. BST-001 (NC) ASD300-2 RX X O 2. For examples of how to assem- ASLD300-2 ble selector switches, see A3-82. L XOX ASD3K00-2 BST-010S (NO-EM) RO O X L OXO BST-001S (NC-LB) RX X O 3 Position Push/Pull Switches Operator Position Contact Pull Normal Push BST-010 (NO) O O X BST-001 (NC) X O O AYLD22 BST-010S (NO-EM) O X X BST-001S (NC-LB) X X O www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-187 ø30mm - TWTD Series Oiltight Switches & Pilot Devices Accessories — TWTD Series Lamp Removal Tool used to install LED’s and incandescent lamps. OR-55 Tool A4 Standard octagonal units (chrome-pl.). OG-81 Extended, non-illuminated (chrome-pl.). OG-82 Metal Bezel Replacement locking ring/bezel Extended, illuminated (chrome-pl.). OG-83L Jumbo Mushroom Shallow Shroud ABN4G Jumbo Mushroom Deep Shroud ABN4F Plastic Bezel Black plastic locking ring/bezel OGP11B In place of ➀, specify neoprene Rubber Boot OC-11 ➀ color: B (black), G (green), R (red), Y (yellow) Used to cover and protect push- Boot/Cover Flush units (clear plastic -40˚ to +60˚C). OC-121 buttons. Extended units (clear plastic -40˚ to +60˚C). OC-122 Plastic washer OGL-D1T For nameplates or panels that should not be scratched. Anti-Rotation Ring Thrust washer/Anti-rotation ring for use with notched panel cutout. OGL-D1S Plastic with locking nut attached. OBP-11 Mounting Hole Plugs used to Ţll unused 30mm Metal with locking nut attached OB-11 panel cutouts. Plug Grey rubber (-5˚ to +60˚C) OB-13 Terminal Tab Tab #250 17/64" x 3/64" (6.35mm x 0.8mm): Single tab TW-FA1 Adaptor Full Voltage Used on all full voltage illuminated units. APD-F Two required per unit. (M3.5 screw and saddle) Adaptor Used to provide lockout protection for TWTD pushbuttons and knob selectors. Lock Out Adaptor OL-KL1 Ş 1-13/64" (30mm) Replacement Pair of Keys (#0) TW-SK Keys A4-188 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices N-VL2 N-VL4 N-VL3 Oiltight Switches & Pilot Devices ø30mm - TWTD Series Accessories con’t Part Numbers: Fingersafe Covers for TWTD Series Appearance Description Used with Part Number A4 Fingersafe terminal cover, for full voltage pilot lights, adds APD199... full voltage pilot lights APD-PVL 3mm to overall depth APD-PVL Fingersafe terminal cover, for contact blocks, adds 3mm to overall depth Non-Illuminated pushbuttons ABD..., and AOD... N-VL2 Fingersafe terminal cover, adds 1.5mm to overall depth Transformer pilot lights and illuminated units N-VL3 Fingersafe terminal cover, adds 4 mm to depth Full voltage illuminated pushbuttons N-VL4 Dimensions on page A4-192. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-189 ø30mm - TWTD Series Oiltight Switches & Pilot Devices Nameplates — TWTD Series Part Numbers: Nameplates NALD NAKD NAQD HNAV 1.95" (50mm) 2.03" (52mm) 1.56" (40mm) A4 Emergency Ø1.19" Dimensions (30.5mm) Ø1.19" Ø1.19" Ø1.19" (30.5mm) (30.5mm) (30.5mm) 5mm Stop Description Part Number Part Number Part Number Part Number Black NALD-B NAKD-B NAQD-B Nameplate HNAV-0 (blank) Red NALD-R NAKD-R NAQD-R Nameplate NALD-➀NAKD-➀NAQD-➀HNAV-27 “Emergency Stop” (engraved) 1. Nameplates are made of 0.031" aluminum. Lettering is white letters engraved on black background. 2. In place of ➀, insert either the standard legend code from table below or custom engraving delimited by “ “. 3. HNAV available in yellow only. * Standard Legend Codes Pushbuttons Pushbuttons/Selector Switches Selector Switches Legend Code Legend Code Legend Code Legend Code Legend Code AUTO-MAN-OFF 301 AUTO 101 OPEN 116 AUTO-MAN 201 AUTO-OFF-MAN 302 CLOSE 102 OUT 117 CLOSE-OPEN 202 CLOSE-OFF-OPEN 303 DOWN 103 RAISE 118 DOWN-UP 203 DOWN-OFF-SLOW 304 *EMERG.STOP 104 RESET 119 FAST-SLOW 204 FAST-OFF-SLOW 305 REV-FOR 216 FAST 105 REVERSE 120 FOR-REV 205 FOR-OFF-REV 306 RUN-JOG 217 FORWARD 106 RUN 121 HAND-AUTO 206 LEFT-OFF-RIGHT 307 RUN-SAFE 218 HAND 107 SLOW 122 HIGH-LOW 207 LOWER-OFF-RAISE 308 SAFE-RUN 219 HIGH 108 START 123 JOG-RUN 208 OFF-MAN-AUTO 309 SLOW-FAST 220 IN 109 *STOP 124 LEFT-RIGHT 209 OFF-SLOW-FAST 310 START-STOP 221 INCH 110 STOP 125 LOWER-RAISE 210 OFF-1-2 311 STOP-START 222 JOG 111 TEST 126 MAN-AUTO 211 OPEN-OFF-CLOSE 312 UP-DOWN 223 LOW 112 UP 127 OFF-ON 212 SLOW-OFF-FAST 313 LOWER 113 I (Int’l On) 150 ON-OFF 213 SUMMER-OFF-WINTER 314 OFF 114 O (Int’l Off) 151 OPEN-CLOSE 214 UP-OFF-DOWN 315 ON 115 EMO 152 RAISE-LOWER 215 1-OFF-2 316 HAND-OFF-AUTO 317 1. *Available in Red as standard legend code 104 and 124. To order engraved nameplate and codes, add legend code to nameplate part number. Character height based on the number of characters, space and size of nameplate. Standard character size is 3/16". 2. Nameplates with standard legends are the same list price as blank nameplates. Special engravings, additional cost. To specify engraving instructions, use the Nameplate order form on next page. A4-190 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices 1.85" (47.5mm) 2.24" (57.5mm) 1.95" (50mm) 2.34" (60mm) Switches & Pilot Devices Oiltight Switches & Pilot Devices ø30mm - TWTD Series Nameplates Order Form — TWTD Series Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. To insure engraving accuracy, fax it to your IDEC representative or Distributor. Your Company: IDEC Rep/Distributor Contact: Name: PO number (if known): Telephone: IDEC Rep/Distributor Phone: A4 Fax & Email IDEC Rep/Distributor Fax & Email NALD Nameplate Step 1. Sample Letter Sizes Engraving 7/64” 7/64” Letters: Choose Letter Size - 7/64” or 1/8”. 16 characters max Letter Location A B C D (for 7/64” size letters) Check the box for the letter size you Size want. Then write your lettering in box 1/8” Letters: below checkboxes. Note: 1/8” size 1/8” A B C D letters cannot exceed 13 characters. 13 characters max Letter (for 1/8” size letters) Size Step 2. Specify Quantity. Enter the number of nameplates desired in Qty the box on the right. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NAKD Nameplate Step 1. 1/8” Letter Size Only Specify Lettering Engraving Write your lettering in box to the Location right. Maximum 17 characters per line, maximum 4 lines. Step 2. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Specify Quantity. Enter the number of Sample Letter Size nameplates desired Qty 1/8” Letters: A B C D in the box on the right. NAQD Nameplate Step 1. 7/64” Choose Letter Size - 7/64” 20 characters max Engraving Letter or 1/8”. (for 7/64” size letters) Location Size Check the box for the letter size you want. Then write your letter- 1/8” ing in box below checkboxes. 16 characters max Letter Note: 1/8” size letters cannot (for 1/8” size letters) Size exceed 16 characters. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Step 2. Specify Quantity. Sample Letter Sizes Enter the number of 7/64” Letters: A B C D nameplates desired in the Qty 1/8” Letters: A B C D box on the right. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-191 45° 45° 45° 45° ø30mm - TWTD Series Oiltight Switches & Pilot Devices Dimensions — TWTD Series Pushbutton M3.5 Terminal Screw Panel Thickness 0.8 to 7.5 Pushbuttons Dimension A Dimension B Flush 0.351" (9mm) Ş 0.975" (25mm) Extended 0.566" (14.5mm) Ş 0.975"(25mm) A4 0.663" (17mm) Ş 1.11" (28.5mm) Extended w/Full Shroud 23 5.5 40 ( 9 53 1 or 2 Mushroom blocks) 14.5 0.858" (22mm) Ş 1.56" (40mm) Mushroom w/Full Shroud 76 (3 or 4 blocks) 0.936" (24mm) Ş 1.87" (48mm) Jumbo Mushroom 1.13" (29mm) Ş 2.54" (65mm) Mushroom Pushbutton Ş 1.56" (40mm) w/Full Shroud Panel Thickness 0.8 to 7.5 Mushroom, Pushlock Turn M3.5 Terminal Screw *0.975" (25mm) Ş 1.56" (40mm) Reset and Push-Pull **0.975" (25mm) Ş 1.56" (40mm) Ş 1.56" (40mm) B Note: *Dimension when operator is in reset position. 23 5.5 40 ( **Dimension when operator is in pull position. 53 1 or 2 blocks) A 76 (3 or 4 blocks) Illuminated Pushbuttons M3.5 Terminal Screw M3.5 Terminal Screw Panel Thickness 0.8 to 7.5 Panel Thickness 0.8 to 7.5 w/AC Adapter Full Voltage M3 Terminal Screw M3 Terminal Screw w/Transformer B 5.5 23 40 40 9 9 ( ) 24 63 2 blocks A 97.5 (2 blocks) 86 (4 blocks) 120.5 (4 blocks) Dimension A Dimension B Illuminated Pushbuttons 0.975" (25mm) Ş 0.936" (24mm) Flush w/Full Shroud Pilot Lights 0.995" (25.5mm) Ş 0.936" (24mm) Full Voltage M3.5 Terminal 0.741" (19mm) Ş 0.936" (24mm) Screw Extended w/Full Shroud 0.761" (19.5mm) Ş 0.936" (24mm) M3.5 Terminal Panel Thickness: 0.8 to 7.5 mm Screw Ş 1.56" (40mm) Mushroom *0.975" (25mm) Ş 1.56" (40mm) Pushlock Turn Reset, **0.975" (25mm) Ş 1.56" (40mm) Push-Pull Note: *Dimension when operator is in reset position. A:29.5 9 40 **Dimension when operator is in pull position. B:64.5 22 Selector Switches Key Knob Lever Panel Thickness 0.8 to 7.5 Panel Thickness 0.8 to 7.5 Panel Thickness 0.8 to 7.5 90° 90° 90° M3.5 Terminal Screw M3.5 Terminal Screw M3.5 Terminal Screw 23 5.5 5.5 23 23 9 5.5 40 ( ( 53 1 or 2 53 1 or 2 40 ( 16.5 53 1 or 2 40 ) ) blocks 21 blocks 21.5 ) blocks 38 ( ) 76 (4 blocks) 76 4 blocks ( ) 76 4 blocks Illuminated Knob Panel Thickness 90° M3.5 Terminal Screws 0.8 to 7.5 (including nameplate) M3 Terminal Screw 5.5 23 40 ( ) 63 2 blocks 9 A: 86 (4 blocks) All measurements in mm. ( ), ( ) B: 97.5 2 blocks 120.5 4 blocks 28 A4-192 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC 45° 45° 45° 45° Switches & Pilot Devices ø25 ø35 ø35 ø25 ø35 ø40 ø40 ø40 ø35 ø40 ø40 ø35 ø40 ø24 ø35 ø25 ø35 ø40 ø35 ø40 ø40 Switches & Pilot Devices Oiltight Switches & Pilot Devices ø30mm - TWTD Series Dimensions — TWTD Series con’t Selector Switches Panel Cut-Out Ş 0.195"(5mm) 1. *Jumbo Mushroom < 2.61" (66mm) 2. Minimum mounting centers are applicable to switches with one stack of contact blocks. When mounting two stacks A4 of contact blocks, minimum centers should allow for access Ş 1.20" (30.5mm) to wiring. 1.64" (42mm) 3. The Ø 0.195" (Ø 5mm) recess is necessary when either the nameplate or anti-rotation ring is used. > 1.95" (50mm)* Accessory Dimensions OL-KL1 OGL-31 OC-31 Lock-Out Adaptor 3.25" (82.5mm) Anti-Rotation Ring Pushbutton Clear Boot 1.18" (30mm) 0.398" 0.33" (10.2mm) (8.4mm) Cut-out is the 3.66" (93mm) only difference 2.76" Ø0.858" between TW (70mm) Ø1.07" (22mm) and TWTD (Ø27.4mm) 1.76" Flush: 0.702" (18mm) (44.8mm) Extended: 0.858" (22mm) 3.66" (2.62mm) 0.31" 1.97" (50mm) OB-31 (8mm) 1.16 (29.5mm) Mounting Hole Rubber Plug Ø1.13" 0.137" (Ø29mm) 0.137" (3.5mm) (3.5mm) Ø0.975" (Ø25mm) Finger-Safe Cover N-VL3 N-VL4 N-VL2 0.63" (16mm) 1.22" (31mm) 1.51" (38.4MM) 0.71" (18mm) N-VL3 0.94" 1.71" (18MM) 0.19" 0.41" 0.68" N-VL2 (24mm) (4.7mm) (10.5mm) (17.2mm) 1.5" (38mm) 0.06" 0.26" 0.55" (14mm) (1.4mm) (6.5mm) 1.51" (38.4mm) N-VL4 APD-PVL .413" (10.5mm) .354" (9mm) 1.45" (37mm) APD-PVL www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-193 .256" (6.2mm) 0.24" (6.2mm) 0.13" (R3.2MM) 0.24" (6.2mm) 0.87" (22mm) 1.26" (32mm) 1.73" (44mm) 1.20" (30.4mm) Ø1.27" (Ø32.6mm) 0.61" 0.94" (24MM) (15.5MM) ø30mm - TWTD Series Oiltight Switches & Pilot Devices Instructions — TWTD Series Installation of LED Illuminated Units—Transformer units are rec- Adjustment for Panel Thickness ommended for use in areas subjected to inductive noise. When using full voltage types, install a protection diode as shown below. Use diode with AC Each unit is shipped with several waterproof gaskets which are 0.06" power supply to protect against reverse polarity. Use with DC power supply (1.5mm) and 0.12" (3mm) thick. Combine the gaskets for a dimension approx- A4 to protect against surges and noise. imately equal to panel thickness and install between the bezel and the body of the unit. Terminal LED Terminal X1 X2 A trim washer must be used with a thrust washer or a nameplate to prevent the control unit from rotating in the mounting hole. When using anti-rotation rings (trim washer with thrust washer or nameplate), install as shown below. Diode Make sure that LED illuminated units are installed with correct polarity, as indicated at the terminals. Application Example For Push-To-Test Pilot Light A typical application of illuminated pushbuttons is a push-to-test pilot light which can be used to Thrust check the lamp/LED circuit. Washer Panel Trim Unit Cut-Out Washer Transformer/AC-Adapter Circuit Nameplate Start Stop M2 C L M2 NC NO T Test Selector Switches Pilot L Light The operator shaft of each unit has a recess to identify in which direction to install the handle. Align the handle with the recess. Press color insert (TW- HC1) into the Standard Operating Positions. Full Voltage Circuit Standard operation positions Start OLS 2-Position, 90° 3-Position, 45° Stop M 0 1 2 1 L 2 C NC L M NO Non-Illuminated 3-Position Operators Test T Pilot 1 1 0 0 Light 1 2 0 2 2 Installation of TWTD Series Units TWTD Pilot Lights TWTD Illuminated Pushbuttons, TWTD Selector Switches (Transformer or Full Voltage) Terminal X1 = Positive Terminal X2 = Negative A4-194 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Cam Switches ø30mm - CS Series CS Series — Heavy Duty Cam Switches Key features of the CS Series include: • Wide variety of heavy-duty oiltight cam switches • Operators available up to 12 positions A4 • Switches made with a double circuit contact block • Contact blocks rated 600V, 10A • Ideal for ammeter/voltmeter applications • Built to order — not available in subcomponents • UL listed and CSA certiŢed • NEMA 4, 13 UL Listed CSA CertiŢed File No. E68961 File No. LR48366 10A Rated Thermal Current 120V/5A 240V/3A 480V/2A 600V/1A AC Break Current 24V/8A 110V/8A 220V/1A 440V/0.45A Resistive Break Current 24V/5A 110V/1.2A 220V/0.45A 440V/0.20A DC Break Current Inductive Rated amperage x 1.1 Make Current (A) 500,000 operations minimum (at full rated load) Electrical Life 5,000,000 (at no load) Mechanical Life CS Series Operator Maximum Contacts Series Appearance Cam Angle Position Handle Styles To Be Mounted 30° Up to 12 45° Up to 8 1 to 10 decks; ACSNO 60° Up to 6 YB, SB, PB, FB Up to 20 contacts 90° Up to 4 45° 2 or 3 30° Up to 12 45° Up to 8 1 to 10 decks; HB or ACSNK 60° Up to 6 Up to 20 contacts standard key 90° Up to 4 45° 2 or 3 30° Up to 12 45° Up to 8 1 to 10 decks; UCSQO 60° Up to 6 YB, SB, PB, FB Up to 20 contacts 90° Up to 4 45° 2 or 3 45° 1 to 3 decks; Spring Only 3 YB, SB, PB, FB UCSQM Up to 6 contacts return 1. It is recommended to use spring return (SR) for a maximum of six contacts. 2. Two identical keys come with ACSNK unit. Specify “H" for handle key option. 3. For handle styles, see page A4-200. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-195 Contact Ratings ø30mm - CS Series Oiltight Cam Switches CS Series – Heavy Duty Cam Switches A4 Assembled Oiltight Cam Switches ACSNO – 3 6 6 – ( ) S B - C3013 Series Contact Arrangement ACSNO = Standard Cam Switch (30mm) 1.For standard contact arrangements, use designa- ACSNK = Key Cam Switch (30mm) tions on pages A4-197 and UCSQO = Cam Switch (5 hole mounting) A4-198. UCSQM = 3 Position Spring Return Cam 2.For custom contact arrange- Switch (5 hole mounting) ments, omit contact arrange- ment designation and Number of Levels (Decks) complete the blank order 1 through 10 form on the next page. Note: One level contains two independent contacts.* Handle Number of Positions YB = Knob, Small 2 through 12 SB = Lever, Small PB = Lever, Large FB = Knob, Large Angle HB = Handle Key (ACSNK only) 3 = 30° (12 position max) Blank = Standard Key (ACSNK only) 4 = 45° (8 position max) 6 = 60° (6 position max) 9 = 90° (4 position max) Spring Return Action Blank: Maintained RO = Spring return from left (2, 3 or 4position, 45° only) OR = Spring return from right (2, 3 or 4 position, 45° only) RR = Return from right and left (3 pos, 45° only) 1. *Contact blocks may contain two independent contacts, (a four position switch with four independent contacts only requires two contact blocks). 2. *Caution: switches with 180° or more of rotation may require separate blocks for each contact due to cam overlapping. Contact IDEC for details. 4. Key removable in every 45º position (45, 90, 180, 225, 270, 315, 360). A4-196 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Cam Switches ø30mm - CS Series Contact Arrangements Standard Arrangements 3 4 Terminal Numbers A4 1 2 12 Position Numbers C-1001 C-1002 C-1014 C-1005 C-1008 3 4 3 3 3 4 3 4 4 4 1 1 1 1 2 1 2 2 2 2 12 12 12 123 102 C-2001 C-2002 C-2006 C-2004 C-2008 C-2009 C-2027 8 8 8 8 7 8 7 8 7 8 7 7 7 7 6 6 6 5 6 5 6 5 6 5 6 5 5 5 4 4 4 4 3 4 3 4 3 4 3 3 3 3 2 2 2 1 2 1 2 1 2 1 2 1 1 1 1234 1234 12345 12 12 102 123 C-3001 C-3002 C-3005 C-3013 C-3016 12 12 12 12 11 11 11 12 11 11 10 10 10 10 10 9 9 9 9 9 8 8 8 8 7 7 7 8 7 7 6 6 6 6 6 5 5 5 5 5 4 4 4 4 3 3 3 4 3 3 2 2 2 2 2 1 1 1 1 1 123456 12345 12 123 123 C-4001 C-4002 16 16 15 15 14 13 13 14 12 12 11 11 10 9 10 9 8 8 7 7 6 5 6 5 4 3 4 3 2 2 1 1 123456 78 1234 C-6001 C-6002 C5001 24 24 23 23 20 19 22 22 21 21 17 18 20 20 19 19 16 15 18 18 17 17 13 14 16 16 15 15 12 11 14 14 13 13 9 10 12 12 11 11 7 8 10 10 9 9 6 5 8 8 7 7 3 4 6 6 5 5 2 1 4 4 3 123 3 2 2 1 1 1234 1234 56789 101112 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-197 ø30mm - CS Series Oiltight Cam Switches Contact Arrangements con’t Ammeter Switching C-1012 C-4007 A4 C-4003 C-6003 Voltmeter Switching C-2022 C-3008 C-3009 C-3007 A4-198 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Cam Switches ø30mm - CS Series Order Form (Custom Contact Arrangement) ( ) Series ACSNO A4 *Number of Decks ACSNK Specify Qty = 1, 2, UCSQO 3, 4, 5, 6, 7, UCSQM 8, 9, or 10 * Note: One Deck can drive Handle ACSNO, UCSQO, UCSQM: two independent contacts. YB = Knob, Small Number of Positions SB = Lever, Small Spring Return Unit Angle Positions PB = Lever, Large 30° only 9, 10, 11, 12 Blank = Maintained FB = Knob, Large ACSNO 30° or 45° only 7 or 8 RO = Spring return from left ACSNK* 30°, 45° or 60° 5 or 6 ACSNK: Angle (3 or 4 position, 45° only) HB = Handle Key (option) UCSQO 30°, 45°, 60°, OR = Spring return from right 3 = 30° 2, 3, or 4 90° Blank = Standard Key (3 or 4 position, 45° only) 4 = 45° UCSQM 45° only 3 only RR = Return from right and left 6 = 60° For handle styles, (3 position, 45° only) * ACSNK keys only 9 = 90° see page A4-200. remove at 45°. UCSQM is available in spring-return version only. Contact Arrangement Table Cams Terminal No. Position 123456789 10 11 12 1 and 2 Deck 1 3 and 4 5 and 6 Deck 2 7 and 8 9 and 10 Deck 3 11 and 12 13 and 14 Deck 4 15 and 16 17 and 18 Deck 5 19 and 20 21 and 22 Deck 6 23 and 24 25 and 26 Deck 7 27 and 28 29 and 30 Deck 8 31 and 32 33 and 34 Deck 9 35 and 36 37 and 38 Deck 10 39 and 40 To specify non-standard arrangements (designation not on preceding pages), fill in this table using the following symbols. X = Closed contact (break before make) O = Open contact X X = Overlapping contact (remain on when switch is moved between two positions) If no engraving information is provided, Specifying Nameplate (Optional) a blank nameplate will be supplied. Specifying Legends 1 1 30° 12 45° 2 2 Position 8 11 3 1 _________________________ 7 _________________________ 10 7 3 4 9 5 8 _________________________ 2 _________________________ 6 4 8 6 5 7 3 _________________________ 9 _________________________ 1 1 60° 90° 2 10 ________________________ 4 _________________________ 6 4 2 5 _________________________ 11 ________________________ 3 5 4 3 12 ________________________ 6 _________________________ www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-199 ø30mm - CS Series Oiltight Cam Switches Accessories — CS Series Replacement Handles A4 Part Number CSH-YB CSH-SB CSH-PB CSH-FB CSH-H2B Dimensions 0.79"D x 1.61"H 0.79"D x 1.97"H 1.58"D x 1.97"H 1.58"D x Ø 1.97" 0.95"D x 2.28"H Applicable Models ACSNO, UCSQO, UCSQM ACSNK Replacement Nameplates Size & Shape ❑ 2.52" (64mm) Black Aluminum Part Number CQ CQM CQN ACSNO, Applicable Models UCSQO UCSQM ACSNK 1. Extra cost for engraving, 3/16" min. letter height. For legends with more than ten characters, consult IDEC. 2. Blank nameplates are supplied with all cam switches (they need not be ordered separately). Wiring Clips Part Number Contact Block Jumpers CJ-1 Between cams CJ-2 Same cam Replacement Keys Part Number K301 Pair of keys (#301) A4-200 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Oiltight Cam Switches ø30mm - CS Series Dimensions/Terminal Arrangements/Mounting Holes ACSNO A4 Terminal Arrangement ACSNK Mounting Holes ACSNO ACSNK UCSQO UCSQO UCSQM UCSQM www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-201 ø30mm - ARN Series Mono-Lever Switches ARN Series — Mono-Lever Switches Mono-Lever Switches Ø 1-13/64" (30mm) Contact Blocks Rated for 600V, 10A Key features of the ARN Series include: A4 •Available in 2–, 3–, and 4–positions. • Maintained and spring-return modes available. • Models available with interlock mechanism to prevent inadvertent actuation. UL Listed CSA CertiŢed File No. E68961 File No.LR48366 Operating Temperature -25˚to 50˚C (without freezing) Insulation Resistance 100MΩ 110VDC: 3A 24V AC/DC: 10A 120VAC: 10A Rated Voltage: Current 240VAC: 6A 480VAC: 2A 600VAC: 1A Contact Rating Insulation Voltage 600V AC/DC Rated Thermal Current 10A Electrical Life Over 500,000 operations Part Numbering Guide (Assembled) Part Numbering Guide: Assembled Mono-Levers Example: Part Number ARN4-1012-10.00.02.11-B - - ARN 4 1012 10.00.02.11 ➀ Type ➁ No. of ➂ Lever ➃ Contact Contact Blocks Action Arrangement Description Code Remarks Standard Lever ARN Interlocking lever prevents inad- ➀ Type Short Lever ARNS vertent operation. Interlocking Lever ARNL 1 2 Each contact block contains two ➁ No. of Contact Blocks — 3 independent contacts. 4 Blocked 0 Specify in this order: ➂ Lever Action Maintained 1 Up.Right.Down.Left Spring Return 2 No contacts 00 Specify the number of contacts to 1 NO contact 10 be activated in all active (non- ➃ Contact Arrangement 1 NC contact 01 blocked) positions: 1 NO and 1 NC contact 11 Up.Right.Down.Left 2 NO contacts 20 A4-202 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Specifications Switches & Pilot Devices Mono-Lever Switches ø30mm - ARN Series Mono-Lever Switches (Sub-Assembled) Contact Block + Operator + Complete Part A4 Part Numbers: Standard Mono-Lever Operators Operator Type Lever Operation Mode Part Number Standard Lever 2-Position manual return ARN0-1010-B 3-Position manual return ARN0-1110-B 4-Position manual return ARN0-1111-B 2-Position spring return ARN0-2020-B 3-Position spring return ARN0-2220-B 4-Position spring return ARN0-2222-B Short Lever 2-Position manual return ARNS0-1010-B 3-Position manual return ARNS0-1110-B 4-Position manual return ARNS0-1111-B 2-Position spring return ARNS0-2020-B 3-Position spring return ARNS0-2220-B 4-Position spring return ARNS0-2222-B Interlocking Lever 2-Position manual return ARNL0-1010-B 3-Position manual return ARNL0-1110-B 4-Position manual return ARNL0-1111-B 2-Position spring return ARNL0-2020-B 3-Position spring return ARNL0-2220-B 4-Position spring return ARNL0-2222-B Part Numbers: Contact Blocks Contact Arrangement Part Number 2NO contacts BR-1E 1NO & 1NC contact BR-2E 2NC contacts BR-3E 1NO early make contact BR-1EM To calculate the number of contact blocks required, add the number of NO and NC contacts on each pair of adjoining positions (up + right, right + down, down + left, and left + up). The largest of the four sums is the number of contact blocks required. Up to four contact blocks can be mounted. Replacement Parts Item Part Number Bellows ARN0, ARNS0 ARN-BL (standard & short lever) ARNL0 ARNL-BL (Interlocking) (comes in 2 pieces) Knob (ball) All Models Knob (ball) ARNB-B www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-203 ø30mm - ARN Series Mono-Lever Switches Dimensions — ARN Series ARNO ARNSO A4 Mounting Hole ARNLO ARNO ARNSO ARNLO A4-204 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Miniature Switches & Pilot Devices Miniature ø8mm A8 Series A8 Series — Miniature Switches and Pilot Devices: 8mm Key features of the 21/64" (8mm) A8 series Switches and Pilot Devices include: • 21/64" (8mm) round mounting hole • Compact Design Saves Space A5 • Bright and Vivid Illumination • Choice of Shapes and Functions • Gold Clad Silver Contacts for reliable low level switching • Snap action contacts • IP40 (Dustproof) Construction CSA CertiŢed UL Recognized File No. LR21451 File No. E55996 50,000 hours approximately LED Lamp Life (reduced to half of original intensity) Contact Configuration SPDT Maximum Voltage 250V AC/DC Thermal Current 3A Contact Material Gold-clad Silver Terminal Style Solder Tab Terminal Operating Temperature –25° to +55°C (no freezing) Operating Humidity 45 to 85% RH Contact Resistance 50mΩ maximum (initial value) 100MΩ minimum Insulation Resistance (500V DC megger) Vibration Resistance 5 to 55Hz, 0.75mm amplitude 2 Damage limits: 500m/sec (approx. 50G) Shock Resistance 2 Operating extremes: 200m/sec (approx. 20G) Electrical Life 100,000 operations minimum Maintained: 100,000 (1200 operations/hour) Mechanical Life Momentary: 200,000 minimum Degree of Protection IP40 Enclosed/Dustproof Soldering Temperature 20W/5 seconds or 260°C/3 seconds Switch Unit: 2,000V AC, 1 min. between live/dead part and terminals of different poles; 1,000V AC, 1 minute between Dielectric Strength terminals of the same pole; 1,500V AC, 1 minute between contact and lamp terminals. Illumination Unit: 2,000V AC, 1 min. between live part/ground Operating Voltage 24V 120V 240V Resistive — 1.0A 0.5A AC 50/60Hz Inductive — 0.7A 0.5A Resistive 1.0A 0.2A — DC Inductive 0.7A 0.1A — 1. AC Inductive Load, PF = 0.6 – 0.7; DC Inductive Load, L/R = 7. 2. Minimum applicable load (reference value) is 5V AC/DC 3mA (applicable range is subject to the operating conditions and load). www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A5-205 Contact Ratings Specifications Miniature ø8mm A8 Series Miniature Switches & Pilot Devices AB8 Non-Illuminated Pushbuttons (Assembled) Part Numbers: Non-Illuminated Pushbuttons Part Numbers Style Contact Momentary Maintained A5 Round SPDT AB8M-M1-①AB8M-A1-① Square SPDT AB8Q-M1-①AB8Q-A1-① Rectangular SPDT AB8H-M1-①AB8H-A1-① 1. In place of ①, specify button color code from the table below. 2. For accessories, see page A5-208. 3. For dimensions, see page A5-209. ① Button Color Code Color Code Black B Green G Red R Blue S White W Yellow Y A5-206 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Miniature Switches & Pilot Devices Miniature ø8mm A8 Series AL8 Illuminated Pushbuttons and Pilot Lights (Assembled) Part Numbers: LED Illuminated Pushbuttons and Pilot Lights Pushbutton Part Number Pilot Light Style Contact Part Number Momentary Maintained A5 Round SPDT AL8M-M11-➁AL8M-A11-➁AL8M-P1-➁ ➁ Lens/LED Color Code Color Code Amber A Square Green G SPDT AL8Q-M11-➁AL8Q-A11-➁AL8Q-P1-➁ Red R White W Yellow Y Rectangular SPDT AL8H-M11-➁AL8H-A11-➁AL8H-P1-➁ 1. In place of ➁, specify lens color code from table on the right. 2. A replaceable LED lamp is included with the operator. 3. Because the LED lamp does not contain an internal current limiting resistor, an external resistor must be added. For recommended values, see table below. 4. For accessories, see page A5-208. 5. For dimensions, see page A5-209. Part Numbers: Replacement LEDs LED Voltage and Recommended Current Limiting Resistor Lens Color LED Lamp Part Number Voltage External Resistor Amber Amber LAD-SA 5V DC 150Ω, 1/2W 6V DC 200Ω, 1/2W Green Green LAD-SG 12V DC 510Ω, 1W 24V DC 1.1kΩ, 1W Red Red LAD-SR White Yellow* LAD-SY Yellow Yellow LAD-SY * White units use a white lens and a yellow LED. LED Lamp Ratings Forward Forward Voltage Reverse Operating Voltage & External LED Current (Nominal) Voltage Current Limiting Resistor Lamp I V V (Recommended Value) f f r Amber 20mA 2.2V 4V 5V DC: 150Ω, 1/2w Green 20mA 2.1V 4V 6V DC: 200Ω, 1/2w Red 20mA 1.7V 4V 12V DC: 510Ω, 3/4w Yellow 20mA 2.2V 4V 24V DC: 1.1kΩ, 3/4w When LED lamps are used at voltages other than those stated above, external resistor value, R, is determined by the following formula: R = (Operating Voltage – V ) / I f f www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A5-207 LED Specifications Miniature ø8mm A8 Series Miniature Switches & Pilot Devices Accessories — A8 Series: 21/64" (8mm) Appearance Description Used With Part Number Locking Ring Wrench Made of metal. Used for tightening plastic lock- A5 ing ring during installation. Tightening torque All units MT-004 should not exceed 3kgf-cm Lens Removal Tool Made of metal. Used for removing lens or button Illuminated pushbuttons and pilot lights MT-101 from the housing Lamp Holder Tool Made of rubber. Used for removing and replacing Illuminated pushbuttons and pilot lights OR-66 LED lamps in illuminated units Switch Guard Round & square units AL-K8 Used to avoid operating the pushbutton inadvert- ently. Cover ţips open 90˚. Provides IP40 protec- tion Rectangular units AL-KH8 Terminal Cover Made of translucent nylon. Fits over and shields All units AL-V8 the terminals Adaptor Socket Plug-on adaptor with solder terminals, allows AL-C8 easy control unit replacement. All units Plug-on adaptor with PCB terminals, allows easy AL-C8V control unit replacement. Mounting Hole Plug Made of rubber. Fills unused mounting holes to Extra panel cutouts AL-B8 provide IP65 protection Replacements LEDs LAD-SR (red) LED lamp is included in every illuminated control LAD-SG (green) unit. Replacement lamp is ordered separately. Illuminated units and pilot lights External current limiting resistor required. LAD-SA (amber) LAD-SY (yellow) Round AL8M-W Illuminated pushbut- Replacement Engraving Inserts Square AL8Q-W tons & pilot lights Rectangular AL8H-W Round AL8M-LK1-➁Replacement Lenses Illuminated pushbut- Square AL8Q-LK1-➁ tons & pilot lights Rectangular AL8H-LK1-➁ Round AB8M-BK1-①Replacement Buttons Non-Illuminated but- Square AB8Q-BK1-① tons Rectangular AB8H-BK1-① 1. In place of ①, specify Button Color Code from the table on the right.① Button Color Code ➁ Lens/LED Color Code 2. In place of ➁, specify Lens Color Code from table on the right. Color Code Color Code Color Code Black B Blue S Amber A Green G White W Green G Red R Yellow Y Red R White W Yellow Y A5-208 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Miniature Switches & Pilot Devices Miniature ø8mm A8 Series Dimensions — A8 Series: 21/64" (8mm) AΔ8 Pushbuttons Panel Cut-Out (not drawn to scale) Terminal 0.3t × 0.8W Rectangular Ø 0.315" (+0.008, –0) 33 6.3 33 Ø 8mm (+0.2, -0) A5 0.354" (9mm) 8.8 17 5 17 3 0.472" Solder Terminal PC Board Terminal (12mm) ( ) ( ) AL-C8 AL-C8V Round/Square Ø 0.315" (+0.008, –0) Ø 8mm (+0.2, -0) Terminal Arrangement (TOP) 6.3 NC 0.354" (9mm) NO COM Lamp Lamp +0.2 0.354" 0 Terminal (+) Terminal (–) 5-1.0 hole (9mm) (PC Board Mounting (BOTTOM VIEW) Switch Guard, Ø 21/64" (8mm) Hole Layout) 0.839" (21.5) Panel Thickness: 0.019 to 0.195" (0.5 to 5.0) Rectangular Square Round 0.354" 0.488" (12.5) (9mm) AL-K8, Ø 21/64" (8mm) AL-KH8, Ø 21/64" (8mm) Round and Square Rectangular 0.39" (10) 0.468" (12) 0.332" 0.332" 0.472" 0.354" 0.354" (8.5) (8.5) (12mm) (9mm) (9mm) Terminal Arrangement 0.683" min 0.683" min 0.234" 0.234" (17.5min) (17.5min) (Bottom View) (6) (6) NC 0.429" min 0.507" min (11min) (13min) NO COM ( + ) ( – ) Terminal Sockets Lamp Lamp AL-C8, Ø 21/64" (8mm), Solder 0.246" (6.3) 1.287" (33) 0.098" (2.5) Terminal Cover AL-V8, Ø 21/64" (8mm) 0.098" (2.5) 0.663" 0.343" (8.8) (17) 0.677" (17.3) 0.195" (5) Ø 0.355" AL-C8V, Ø 21/64" (8mm), PCB (Ø 9.1) Terminal: 0.012 x 0.031" (0.3 x 0.8) 1.307" (33.5) 0.246" (6.3) 1.287" (33) 0.098" (2.5) 0.098" (2.5) 0.663" +0.008 (17) 5 - Ø 0.039" -0 0.117" (3) +0.2 (Ø 1.0 ) Holes -0 PC Board Drilling Layout Bottom View www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A5-209 2.5 2.5 2.5 2.5 0.566" (14.5) 0.566" (14.5) Miniature ø8-16mm AP Series Miniature Pilot Lights AP Series — Miniature Pilot Lights Miniature Pilot Lights with Super Bright LEDs Key features of AP series include: • Long service life, low maintenance • Space saving miniature style A5 AP8 • Dome or ţat lens models • Built-in current-limiting resistor and reverse polarity protection diode • Five illumination colors: red, green, amber, yellow, and white • AC adaptor (120V AC and 240V AC) and DC-DC Converter (110V DC) options on 12mm and 16mm units AP1 CSA CertiŢed UL Recognized File No. LR92374 File No. E68961 Built-in LED with current limiting resistor Lamp AP2 6, 12, 24VDC (full voltage), Operational Voltage 110/120, 220/240VAC, (transformer) 110VDC (with converter) AP8: 6VDC/18mA, 12VDC/18mA, 24VDC/12mA AP1: 6VDC/18mA, 12VDC/18mA, 24VDC/12mA Current Ratings AP2: 6VDC/33mA, 12VDC/22mA, 24VDC/11mA AP6: 6VDC/33mA, 12VDC/22mA, 24VDC/11mA -20°C to +55°C Operating Temp. 45 to 85% RH Operating Humidity AP6 100MΩ min. (500V DC megger) Insul. Resistance Between live and dead parts AP2/AP6: 100V Rev. Withstand Voltage AP1/AP8: 200V Soldering 260°C maximum (5 sec.) Solder Terminal AP8: IP40 (dustproof) Degree of Protection Other Series: IP65 (oiltight) AC Adaptor DC-DC Converter AP2 & AP6 (with 6V LED only) Applicable Units 110/120VAC 50/60 Hz Operating Voltage 110V DC (90 to 140V DC) 220/240VAC 50/60 Hz 1.6 VA maximum 1W maximum Power Consumption 250 V AC 140V DC Insulation Voltage 10MΩ min. (500V DC megger) Between live and dead parts Insulation Resistance 2,000V AC, 1 minute Between live/dead parts 2,000V AC, 1 minute Between live/dead parts Dielectric Strength 2,000V AC, 1 minute Between terminals 1,500V AC, 1 minute Between terminals Available as one piece only (replacement LEDs are not available). A5-210 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Optional Adaptors/Converters Specifications Switches & Pilot Devices Miniature Pilot Lights Miniature ø8-16mm AP Series Miniature Pilot Lights (Assembled) Part Numbers: AP Miniature Pilot Lights Appearance Lens Style Operating Voltage Part Numbers AP8M266-➁6V DC +/- 5% AP8 Series - Ş 8mm A5 Dome 12V DC +/- 10% AP8M211-➁ 24V DC +/- 10% AP8M222-➁ AP8M166-➁6V DC +/- 5% Flat 12V DC +/- 10% AP8M111-➁ 24V DC +/- 10% AP8M122-➁ AP1 Series - Ş 10mm 6V DC +/- 5% AP1M266-➁ Dome 12V DC +/- 10% AP1M211-➁ 24V DC +/- 10% AP1M222-➁ ➁ Color Code Color Code AP1M166-➁6V DC +/- 5% Flat 12V DC +/- 10% AP1M111-➁ Amber A 24V DC +/- 10% AP1M122-➁ Green G Red R AP2 Series - Ş 12mm 6V DC +/- 5% AP2M266-➁ White W Dome 12V DC +/- 10% AP2M211-➁ 24V DC +/- 10% AP2M222-➁ Yellow Y AP2M166-➁6V DC +/- 5% Flat 12V DC +/- 10% AP2M111-➁ 24V DC +/- 10% AP2M122-➁ AP6 Series - Ş 16mm AP6M266-➁6V DC +/- 5% Dome 12V DC +/- 10% AP6M211-➁ 24V DC +/- 10% AP6M222-➁ AP6M166-➁6V DC +/- 5% Flat 12V DC +/- 10% AP6M111-➁ 24V DC +/- 10% AP6M122-➁ 1. In place of ➁, specify the color code. 2. For dimensions, see page A5-212 3. For accessories, see page A5-212. Part Numbers: Optional AC Adaptors and DC-DC Converters (for AP2 and AP6 only) Part Numbers Appearance Style Voltage Used with Used with AP2 Series AP6 Series AC 110/120V AC AP2-0126D AP6-0126D Adaptor 220/240V AC AP2-0246D AP6-0246D DC-DC 110V DC AP2-016DD AP6-016DD Converter (90–140V DC) Secondary Voltage = 6V 1. Optional AC adaptors and DC-DC converters snap onto the back of AP2 or AP6 pilot lights. 2. AC Adaptors and DC-DC Converters step down to 6V. 3. For dimensions, see page A5-213. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A5-211 Miniature ø8-16mm AP Series Miniature Pilot Lights Accessories — AP Series Appearance Description Used With Part Number Ş 16mm units MT-001 Locking Ring Wrench A5 Made of metal. Used for tightening plastic lock- Ş 12mm units MT-002 ing ring during installation. Tightening torque Ş 10mm units MT-003 should not exceed 3kgf-cm Ş 8mm units MT-004 Mounting Hole Plug Unused 8mm panel cutouts AL-B8 Unused 10mm panel cutouts AL-B1 Made of rubber. Fills unused mounting holes to provide IP65 protection Unused 12mm panel cutouts AL-B2 Unused 16mm panel cutouts AL-B6 AP2 & AP6 snap on transformer & DC-DC Transformer Removal Tool MT-100 converter AP1M Flat AP1M-L1-➁ Replacement Lenses AP1M Dome AP1M-L2-➁ AP2M Flat AP2M-L1-➁ Lenses (included with all units). AP2M Dome AP2M-L2-➁ AP6M Flat AP6M-L1-➁ AP6M Dome AP6M-L2-➁ Replacement Engraving Inserts AP1M Flat AP1M-P1-W AP2M Flat AP2M-P1-W Allow legends under ţat lenses (included with all ţat lens models). AP6M Flat AP6M-P1-W In place of ➁, specify the Lens Color Code. ➁ Lens Color Code Color Code Amber A Green G Red R White W Yellow Y A5-212 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Switches & Pilot Devices Miniature Pilot Lights Miniature ø8-16mm AP Series Dimensions — AP Series Pilot Lights (AP Series) Style AP8 AP1 AP2 AP6 w/ Adaptor w/ Adaptor A5 Flat Dome Flat Dome Flat Dome Flat Dome or Converter or Converter Ş 0.319" (+0.0118, –0) Ş 0.398" (+0.0118, –0) Ş 0.480" (+0.0118, –0) 12.2mm (+0.3, –0) Ş 0.638" (+0.0118, –0) 16.2mm (+0.3, –0) Panel Cut-out 8.1mm (+0.3, –0) 10.1mm (+0.3, –0) Outside Ş 0.386" (9.8mm) Ş 0.472" (12mm) Ş 0.551" (14mm)❑ 0.709" (18mm) Ş 0.709" (18mm)❑ 0.709" (18mm) Dimension Panel Thickness: 0.8 to 6 mm Panel Thickness: 0.8 to 6 mm Gasket Gasket Round Extended Round Extended 1.5 2.2 1.5 2.2 + - 5.5 21.5 5.5 21.5 8 11.5 29.5 13.5 29.5 Round Flush Panel Cut-out Panel Cut-out Round Flush 5.5 5.5 9.5 9.5 When using the AC adapter unit AC adapter unit M3 terminal (When using the DC-DC converter unit) (or DC-DC converter unit) screw + Terminal M3 terminal AC adapter unit screw + Terminal When using the AC adapter unit (When using the DC-DC converter unit) (or DC-DC converter unit) 58.7 18 71 58.7 18 1.3 – Terminal 71 1.3 – Terminal 2.2 1.5 2.2 1.5 Panel Thickness: 0.8 to 6 mm Panel Thickness: 0.8 to 6 mm Gasket Gasket Round Extended Round Extended 8 5.5 21.5 5.5 21.5 8 9.5 10 29.5 29.5 Panel Cut-out Panel Cut-out Round Flush Round Flush 5.5 5.5 8.5 9.5 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A5-213 +0.2 0 ø 12.2 ø 16.2 0 +0.2 +0.2 0 ø8.1 ø 10.1 +0.2 0 ø12 ø12 ø18 ø18 ø10 ø10 ø15.6 ø15.6 TOP 4 2.8 7 - + X2 X1 18 ø14 ø14 ø9.8 ø9.8 ø12 ø12 ø8 ø8 TOP 5 2.8 3 - + X2 X1 18

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the AS6M-21Y2P?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Switch Selector N.O./N.C. 4PST 90 Lever 10A 440VAC 220VDC Screw 250000Cycles Panel Mount ABN6122-B

product

Switch Selector N.O./N.C. 4PST 90 Lever 10A 440VAC 220VDC Screw 250000Cycles Panel Mount ABN7122-B

product

Switch Selector N.O./N.C. 4PST 90 Lever 10A 440VAC 220VDC Screw 250000Cycles Panel Mount ABN7322-B

product

Switch Selector N.O./N.C. DPDT 90 Knob 1A 250VAC 250VDC Quick Connect/Solder 250000Cycles Panel Moun...

product

Switch Selector N.O./N.C. DPDT 90 Knob 1A 250VAC 250VDC Quick Connect/Solder 250000Cycles Panel Moun...

product

Switch Selector N.O./N.C. DPDT 45 Knob 1A 250VAC 250VDC Quick Connect/Solder 250000Cycles Panel Moun...