Electronics Finder chervon right Manufacturers chervon right I chervon right IDEC CORPORATION chervon right FL1D-K2BM2
About product Specifications Datasheet FAQ

IDEC CORPORATION FL1D-K2BM2

Image of IDEC CORPORATION FL1D-K2BM2

Description

I/O Module Relays I/O Module DIN Rail
FL1D-K2BM2

Part Number

FL1D-K2BM2

Price

Request Quote

Manufacturer

IDEC CORPORATION

Lead Time

Request Quote

Category

Relays and I/O Modules »  I/O Module

Specifications

Manufacturer

IDEC Corporation

Manufacturers Part #

FL1D-K2BM2

Lead Time

10 Week Lead Time

Industry Aliases

FL1D-K2BM2

Sub-Category

I/O Modules

Factory Pack Quantity

1

Datasheet

pdf file

SmartRelaySeries.pdf

687 KiB

Extracted Text

SmartRelay Series Programmable Logic Controllers SmartRelay Series IDEC SmartRelay – The Intelligent Choice Increase your versatility with a new remote display Look around. IDEC SmartRelays are in everything from lighting controls to ice- With an ever changing market and tough competition, you need an edge to making machines and grocery store misters. Proving reliable time after time, stay on top. SmartRelay has a new HMI text display panel to do just that! This these intelligent logic modules are the ideal controller for simple automation economical interface lets you make quick adjustments, while at the same time tasks. A new fifth-generation of SmartRelays offer functions to give you even making it easy to spot and troubleshoot failures using built-in operator functions more flexibility and convenience. Advances include extended memory, a brighter and diagnostics. So why wait? Make the smart choice, IDEC SmartRelay! display with higher LCD contrast, improved analog and high-speed inputs, an external text display, and upgraded programming software. Industrial Facility Systems Unique Solutions • Conveyor systems • Solar-electric systems • Elevator controls • Marine systems • Exhaust and filtering systems • Extreme environmental conditions • Automatic food dispensing machines • Display panels and traffic light controls • Water treatment and irrigation systems • Energy management • Motor, pump and valve controls Housing and Building Management Monitoring Systems • Lighting controls (outside and inside) • Access controls • Door and gate controls • Alarm systems • Heating and cooling systems • Limit level monitoring • Shutter, sun blind and awning controls • Parking Lot monitoring • Water and sprinkler systems • Baggage control • Ventilation systems www.IDEC.com/smartrelay www.IDEC.com 110 Barriers Communication Sensors Power Supplies Automation Software PLCs OI Touchscreens OI Touchscreens PLCs Automation Software Power Supplies Sensors Communication Barriers SmartRelay Series Programmable Logic Controllers New Built-in Analog Inputs New Memory Cartridges Each SmartRelay is equipped with 8 digital inputs that can be used Three memory cartridges are now available for for your applications. New in the FL1E 12/24VDC and 24VDC models FL1E: Violet, Green and Brown! Violet is a 32K are four built-in analog inputs. Inputs I1, I2, I7, and I8 can now be high-capacity, removable program memory card. New Faster Inputs configured to accept 0-10V analog signals. Using expansion modules, Green is a battery card that supports a Real Time FL1E can support up to four 5KHz high- you can utilize a maximum of 24 digital and 8 analog inputs. Clock power supply for up to two years. Brown is speed inputs. You have the option of a combined memory/battery card. configuring inputs I3, I4, I5 and I6 as fast counter inputs to give you even more Memory and Memory Battery flexibility. Battery Universal Voltages Available in 12/24V DC for solar and vehicle applications, and 24V AC/DC for building automation, as well as 100-240V AC/DC, SmartRelay can be used for a wide variety of applications. DIN Rail or Surface Mountable Operational Control Buttons Program with just the push of a button! Smart- Relay control buttons can be used to program, modify and change preset parameters. The four cursor keys can also be configured as inputs as needed. New Controllable Backlit LCD Display Digital Outputs FL1E SmartRelays have a built-in LCD display with a brighter, IDEC SmartRelays are equipped with four relay higher contrast screen you can adjust to your own preference. outputs rated at 10A/pt. Using digital expan- System status — input, output, analog values, timers and sion modules; you can configure a maximum of counters — can be monitored through the 4x12 LCD screen or sixteen outputs. you can display a predefined message with up to 48 characters (chosen from 103 special character types). Non-LCD versions New 50% More Memory are also available. FL1E SmartRelays offer an expanded program memory of 200 function blocks! This is a 50% increase compared to the existing FL1D series. EEPROM Memory Additional text display With IDEC SmartRelays, your program is stored in a non-volatile EEPROM For the first time ever, you can connect an external text display to your SmartRe- Memory. lay, making it easy for you to monitor, view and troubleshoot from outside your panel. Turn to page 7 to learn more! New Extended Retentive Data Memory Extended memory gives you up to 250 bytes of retentive data memory. More Quality than 4 times that of FL1D! IDEC has built a reputation based on providing high-quality, dependable products you can trust, and our SmartRelays are no exception. Each model is cULus listed, New Arithmetic Functions CE certified, EMC compliant, FM approved for Class 1 Div 2 hazardous locations, Analog Math function blocks allow basic arithmetic operations such as C-tick compliant, Lloyds Registered and ABS approved. addition, subtraction, multiplication, and division. Password Protection FM Concerned about your program being copied or altered? IDEC SmartRelays keep APPROVED you safe with a unique password protection scheme allowing end users to ac- cess certain parameters without seeing or modifying the actual program. 800-262-IDEC (4332) • USA & Canada 111 SmartRelay Series Programmable Logic Controllers Part Numbers Base Modules – with LCD Style Part Number Voltage Input Signal Input Output With Clock FL1E-H12RCE 12/24V DC Relay DC I1, I2, I7 and I8 are used PNP Yes for digital/analog FL1E-H12SND 24V DC Transistor Source FL1E-H12RCA 24V AC/DC PNP/NPN AC/DC Relay Yes FL1E-H12RCC 100-240V AC/DC PNP Base Modules – without LCD Style Part Number Voltage Input Signal Input Output With Clock DC FL1E-B12RCE 12/24V DC I1, I2, I7 and I8 are PNP Relay Yes used for digital/analog FL1E-B12RCA 24V AC/DC PNP/NPN AC/DC Relay Yes FL1E-B12RCC 100-240V AC/DC PNP Text Message Display Style Part Number Rated Voltage Description FL1E-RD1 12 VDC, 24 VAC/DC FL1E Text Display Panel Digital I/O Expansion Modules • 8-pt expansion module (4 in/4 out) • Max. 4 digital expansion modules Style Part Number Total I/O Input Power Input Output FL1B-M08B2R2 12/24V DC Relay DC FL1B-M08B1S2 24V DC Transistor Sink 8 (4 in/ 4 out) FL1B-M08C2R2 100-240V AC/DC AC/DC Relay FL1B-M08D2R2 24V AC/DC www.IDEC.com 112 Barriers Communication Sensors Power Supplies Automation Software PLCs OI Touchscreens OI Touchscreens PLCs Automation Software Power Supplies Sensors Communication Barriers SmartRelay Series Programmable Logic Controllers Analog I/O Expansion Modules • 2-pt Analog input module • 2-pt Analog output module • 10-bit resolution • Max. 4 analog input modules and 1 analog output module Style Part Number Total I/O Input Power Input Output FL1B-J2B2 2 (2 in/0 Out) 12/24V DC 0-10V, 4-20mA — FL1D-K2BM2 2 (0 in/2 Out) 24V DC — 0-10V, 4-20mA AS-Interface Communication Module • The AS-Interface communication module provides optimum solutions for decentralized controls and savings in installation space and wiring • Virtual I/O points: 4 inputs, 4 outputs Style Part Number Module Input Power Total I/O Input: 4 points FL1B-CAS2 AS-Interface Communication Module 30V DC Output: 4 points Starter Kits IDEC SmartRelay Starter Kit is an economical and ideal solution for first time IDEC SmartRelay users • Package includes a base module, WindLGC programming software, USB programming cable, simulator switch (DC models only) and a user’s manual Starter Kits Part Number Description SMARTSTART-BAC-E FL1E-B12RCC, WindLGC software and programming cable SMARTSTART-BDC-E FL1E-B12RCE, WindLGC software, programming cable, and simulator switch SMARTSTART-HAC-E FL1E-H12RCC, WindLGC software and programming cable SMARTSTART-HDC-E FL1E-H12RCE, WindLGC software, programming cable, and simulator switch Accessories Part Number Description FL9Y-LP1CDW WindLGC 6.0 programming software FL1E-PC2 SmartRelay USB programming cable WindLGC Software FL1E-PM4 FL1E SmartRelay memory cartridge FL9Y-LP1CDW FL1E-PB1 FL1E SmartRelay battery cartridge FL1E-PG1 FL1E SmartRelay memory and battery combination cartridge FL9Y-B1090-0 FL1E SmartRelay user’s manual FL1B-Y1371-SW8 8-pt simulator switch, used with 12-24VDC, 24VDC base module only 800-262-IDEC (4332) • USA & Canada 113 SmartRelay Series Programmable Logic Controllers WindLGC Programming Software WindLGC is the exclusive programming software for the IDEC SmartRelay using Windows®. Edit, save, and print out your programs. Key features: • Ladder programming • Online Monitor • Program Comparison • Time Simulation • Simplified connection of the functions • Programs can be saved in PDF or JPG format Just click the function blocks you need and link function blocks for easy wiring. Devise complicated circuits using the convenient functions of WindLGC. Part Number Part Number Description FL9Y-LP1CDW WindLGC programming software for IDEC SmartRelay WindLGC system requirements: Program Comparison • OS: Windows95/98/ME/NT/2000/XP/Vista and Windows 7 • CPU recommendation: Pentium 266MHz or higher • Memory: 64MB or more • RAM recommendation: 128MB • Hard disk space: 90MB or more for installing WindLGC software. • Monitor Recommendation: Display more than 800 x 600 dots and 256 colors • Free download service, if upgrading from WindLGC Version 3.0 to Version 5.0, available at www.idec.com/usa Simulation Mode/Online Monitor Ladder Programming For more information, see the Automation Software section. Visit www.IDEC.com/downloads for free upgrades or a free demo version. www.IDEC.com 114 Barriers Communication Sensors Power Supplies Automation Software PLCs OI Touchscreens OI Touchscreens PLCs Automation Software Power Supplies Sensors Communication Barriers SmartRelay Series Programmable Logic Controllers Specifications Base Modules with LCD Display FL1E-H12SND FL1E-H12RCE FL1E-H12RCA FL1E-H12RCC Style without Display — FL1E-B12RCE FL1E-B12RCA FL1E-B12RCC Rated Power Voltage 24V DC 12/24V DC 24V AC/DC 100 to 240V AC/DC 20.4 to 26.4V AC, 85 to 265V AC, Allowable Voltage Range 20.4 to 28.8V DC 10.8 to 28.8V DC 20.4 to 28.8V DC 100 to 253V DC Rated Frequency — — 47 to 63Hz 47 to 63Hz 60 to 175mA (12V DC) 76 to 182mA (24V AC) 25 to 40mA (100V AC), 20 to 30mA (240V AC) Current Draw 40 to 75mA (24V DC) 40 to 100mA (24V DC) 40 to 100mA (24V DC) 10 to 25mA (100V DC), 6 to 15mA (240V DC) Allowable Momentary Power 2ms (Typ.) (12V DC) 10ms (Typ.) (100V AC/DC) — 5ms (Typ.) (24V AC/DC) Interruption 5ms (Typ.) (24V DC) 20ms (Typ.) (240V AC/DC) 0.3 to 1.7W (12V DC) 0.9 to 2.7VA (24V AC) 1.1 to 4.6VA (100V AC), 2.4 to 6.0VA (240V AC) Power Consumption 0.7 to 1.3W (24V DC) 0.4 to 1.8W (24V DC) 0.4 to 1.8W (24V DC) 0.5 to 2.9W (100V DC), 1.2 to 3.6W (240V DC) Reverse Polarity Protection Yes Yes — — 1 1 1 Backup Duration — 80 hours (25°C) 80 hours (25°C) 80 hours (25°C) Clock Accuracy — ±2 sec/day maximum ±2 sec/day maximum ±2 sec/day maximum Input Signal DC AC/DC AC/DC Input Points 8 (I1 to I8) 8 (I1 to I8) 8 (I1 to I8) Analog Input Points 4 (I1, I2, I7, I8) — — 2 High-speed Input 4 (I3, I4, I5, I6), 5Khz maximum — — Input Range 0 to 10V DC (max. rated input: 28.8V DC) — — Input Error ±1.5 (of full scale) — — Input Resolution 10 bits (0 to 1000) — — Allowable Voltage Range 0 to 28.8V DC — — Digital Input 3.5kΩ 4.8kΩ 840kΩ Input Impedance Analog Input 72kΩ — — Isolation — — — — OFF Voltage < 5V DC < 5V AC/DC < 40V AC, < 30V DC ON Voltage ≥ 12V DC ≥ 12V AC/DC ≥ 79V AC, ≥ 79V DC Operating OFF Current < 0.85mA (I1 to I6), < 0.05mA (I1, I2, I7, I8) < 1.0mA < 0.03mA Range ≥ 2mA (I3 to I6) ≥ 1.5mA (I3 to I6) ON Current ≥ 2.5mA ≥ 0.08mA, 100V AC: 50ms (Typ.) ≥ 0.15mA (I1, I2, I7, I8) ≥ 0.1mA (I1, I2, I7, I8) 100V AC: 50ms (Typ.), 240V AC: 30ms (Typ.) Turn ON Time 1.5ms (Typ.) ≤ 1.0ms (I3, I6) 1.5ms (Typ.) 100V DC: 25ms (Typ.) 240V DC: 15ms (Typ. 100V AC: 65ms (Typ.), 240V AC: 105ms (Typ.) Turn OFF Time 1.5ms (Typ.) ≤ 1.0ms (I3, I6) 15ms (Typ.) 100V DC: 95ms (Typ.), 240V DC: 125ms (Typ.) 3 3 Wire Length 100m 100m 100m 1. Two year backup duration (typ.) when bettery cartridge or memory/battery cartridge used. Specifications con’t on next page. 2. When selecting frequency trigger function and up/down counter function. 3. 10m when connected to analog input (twisted pair cable). 800-262-IDEC (4332) • USA & Canada 115 Input Clock Power Supply Analog SmartRelay Series Programmable Logic Controllers Specifications con’t with LCD Display FL1E-H12SND FL1E-H12RCE FL1E-H12RCA FL1E-H12RCC Style without Display — FL1E-B12RCE FL1E-B12RCA FL1E-B12RCC Output Transistor source Relay Output Points/ Contact Configuration 4 points (separate) 4NO contacts Isolation — Isolated Dielectric Strength 2500V AC, 1 minute, (between power/input terminals — 500V DC, 1 minute and output terminals) Output Voltage External power voltage — Resistive load: 10A at 12/24V AC/DC, 10A at 100/120V AC, 10A at 230/240V AC Maximum Load Current 0.3A Inductive load: 2A at 12/24V AC/DC, 3A at 100/120V AC, 3A at 230/240V AC Surge Current — 30A maximum Built-in current limiting External fuse required: Short-circuit Protection resistor: Approx. 1A 16A maximum Minimum Switching Load — 10mA, 2V DC 10mA, 12V DC Initial Contact Resistance — 100 mΩ maximum (at 1A, 24V DC) Mechanical Life — 10 million operations (no load, 10Hz) Electrical Life — 100,000 operations (rated resistive load) 1800 operations/hour Mechanical Load — 10Hz Electrical Load 10Hz — 1 Resistive Load/Lamp Load 10Hz 2Hz Inductive Load 0.5Hz 0.5Hz 1. For fluorescent lamps, if the inrush current exceeds the allowable value, use an appropriate relay. General Text Display Style Specification Standard Part Number FL1E-RD1 Horizontal Mounting 0 to 55°C Membrane keypad with 10 Operating Cold: IEC60068-2-1 keys, FSTN-Graphic Display Temperature Hot: IEC60068-2-2 Vertical Mounting 0 to 55°C Keyboard Display with 128 x 64 (columns x Storage/Transportation Temperature –40 to +70°C (no freezing) — rows), LED backlight Relative Humidity 10 to 95% RH (no condensation) IEC60068-2-30 Input Voltage 24V AC/DC, 12V DC Atmospheric Pressure 795 to 1080 hPa — 20.4 to 26.4V AC, 10.2 to Allowable Voltage Range 28.8V DC Operating Condition No corrosive gas — Rated Frequency 47 to 63Hz Degree of Protection IP20 — Current Draw 30 to 55mA (24V DC) 5 to 8.4Hz, amplitude 3.5mm Vibration Resistance IEC60068-2-6 2 8.4 to 150Hz, acceleration 9.8m/s 12V DC 65mA 2 Power Shock Resistance 147m/s IEC60068-2-27 24V DC 40mA Consumption Drop Test 0.3m IEC60068-2-31 24V AC 90mA Drop Test (packaged) 1m IEC60068-2-32 Data Transmission Rate 19200 baud 1 1 Emission Class B Group 1 EN55011 Backlight lifetime 20,000 hours LCD 2 Display 2 Electrostatic Discharge 8kV air discharge, 6kV contact discharge IEC61000-4-2 Display lifetime 50,000 hours Radiation Field Immunity Field Strength: 1V/m and 10V/m IEC61000-4-3 Weight 220g 3 Burst Pulses 2kV (power line), 1kV (I/O signal line) IEC61000-4-4 Connect the text display and the base module using the text display cable (2.5m). The text display cable can be extended up 4 Energy Carriers Single Pulse (Surge) 1kV (power line) normal IEC61000-4-5 to 10m using an extension cable (D-sub 9-pin). (FL1E-H12RCC, FL1E-B12RCC only) 2kV (power line) common 1. Backlight durability is the number of hours it takes for the light 2 2 to become 50% of the original brightness. Communication Cable 0.5 to 2.5mm (one wire), 0.5 to 1.5mm (two wires) — 2. Display durability is calculated under ordinary operating and 5 Terminal Style Finger-safe type — storage conditions: room temperature, normal humidity below 65% RH, and not subjected to direct sunlight. 1. Class A for AS-Interface communication module. 4. For protection against surge noise on DC power supply types 2. 8kV (air discharge), 4kV (contact discharge) for (FL1E-H12RCE/B12RCE, FL1E-H12SND, FL1E-H12RCA/B12RCA), AS-Interface communication module. use surge absorbers, noise cut transformers, or noise filters. 3. 1kV (criteria A), 2kV (criteria B) for AS-Interface Use of surge protection device (DEHN + SOHNE GmbH + Co. communication module. VVT AD 24 Part No. 918 402) is recommended. 5. Tightening torque 0.4 to 0.5 N·m. www.IDEC.com 116 Barriers Communication Sensors Power Supplies Automation Software PLCs OI Touchscreens Switching Output Rate Power Supply OI Touchscreens PLCs Automation Software Power Supplies Sensors Communication Barriers SmartRelay Series Programmable Logic Controllers Expansion I/O Module Expansion I/O Module FL1B-M08B1S2 FL1B-M08B2R2 FL1B-M08D2R2 FL1B-M08C2R2 FL1B-J2B2 FL1D-K2BM2 Model Number Rated Power Voltage 24V DC 12/24V DC 24V AC/DC 100 to 240V AC/DC 12/24V DC 24V DC 20.4 to 26.4V AC 85 to 265V AC Allowable Voltage Range 20.4 to 28.8V DC 10.8 to 28.8V DC 10.8 to 28.8V DC 20.4 to 28.8V DC 20.4 to 28.8V DC 100 to 253V DC Rated Frequency — — 50/60Hz (47 to 63Hz) 50/60Hz (47 to 63Hz) — — 10 to 30mA (100V AC) 30 to 140mA (12V DC) 40 to 110mA (24V AC) 10 to 20mA (240V AC) Current Draw 30 to 45mA 25 to 50mA 25 to 50mA 20 to 75mA (24V DC) 20 to 75mA (24V DC) 5 to 15mA (100V DC) 5 to 10mA (240V DC) 2ms (Typ.) (12V AC/ Allowable Momentary Power 2ms (Typ.) (12V DC) 5ms (Typ.) (24V AC/ 10ms (Typ.) (100V AC/DC) DC) — 5ms (Typ.) Interruption 5ms (Typ.) (24V DC) DC) 20ms (Typ.) (240V AC/DC) 5ms (Typ.) (24V AC/ DC) 1.1 to 3.5VA (100V AC) 0.3 to 1.7W (12V DC) 0.9 to 2.7VA (24V AC) 2.4 to 4.8VA (240V AC) 0.3 to 0.6W (12V DC) Power Consumption 0.8 to 1.1W 0.6 to 1.2W (24V DC) 0.4 to 1.8W (24V DC) 0.4 to 1.8W (24V DC) 0.5 to 1.8W (100V DC) 0.6 to 1.2W (24V DC) 1.2 to 2.4W (240V DC) Reverse Polarity Protection Yes Yes — — Yes Yes Input Signal DC input DC input AC/DC input AC/DC input Analog input — Input Points 4 4 4 4 — — Isolation — — — — — — 0 to 26.4V AC 0 to 265V AC Allowable Voltage Range 0 to 28.8V DC 0 to 28.8V DC — — 0 to 28.8V DC 0 to 253V DC < 40V AC OFF Voltage < 5V DC < 5V DC < 5V AC/DC — — < 30V DC ≥ 79V AC Operating ON Voltage ≥ 12V DC ≥ 8.5V DC ≥ 12V AC/DC — — ≥ 79V DC Range OFF Current < 0.85mA < 0.85mA < 1.0mA < 0.03mA — — ON Current ≥ 2mA ≥ 1.5mA ≥ 2.5mA ≥ 0.08mA — — 100V AC: 50ms (Typ.) 240V AC: 30ms (Typ.) Turn ON Time 1.5ms (Typ.) 1.5ms (Typ.) 1.5ms (Typ.) — — 100V DC: 25ms (Typ.) 240V DC: 15ms (Typ.) 100V AC: 65ms (Typ.) 240V AC: 105ms (Typ.) Turn OFF Time 1.5ms (Typ.) 1.5ms (Typ.) 1.5ms (Typ.) — — 100V DC: 95ms (Typ.) 240V DC: 125ms (Typ.) Analog Input Points — — — — 2 — 0 to 10V (max. rated input: 28.8V) Analog Input Range — — — — — 0 to 20mA (max. rated input: 40mA) Digital Resolution — — — — 10 bits (0 to 1000) — Input Error — — — — ±1.5% (of full scale) — 76kΩ (0 to 10V) Input Impedance — — — — 155 to 250Ω (0 to — 20mA) Sampling Cycle — — — — 50ms — Expansion I/O Module Specifications con’t on next page. 800-262-IDEC (4332) • USA & Canada 117 Input Power Supply SmartRelay Series Programmable Logic Controllers Expansion I/O Module, con’t Expansion I/O Module FL1B-M08B1S2 FL1B-M08B2R2 FL1B-M08D2R2 FL1B-M08C2R2 FL1B-J2B2 FL1D-K2BM2 Model Number 10 m (twisted-pair Wire Length 100 m 100 m 100 m 100 m — shielded cable) Output Transistor source Relay Relay Relay — Analog Output Points/ 4 points (sepa- 4NO contacts 4NO contacts 4NO contacts — — Contact Configuration rate) Isolation — Isolated Isolated Isolated — — Dielectric Strength 2500V AC, 1 minute 2500V AC, 1 minute 2500V AC, 1 minute (between power/input termi- — — — 500V DC, 1 minute 500V DC, 1 minute 500V DC, 1 minute nals and output terminals) External power voltage Output Voltage — — — — — (20.4 to 28.8V DC) Resistive load Resistive load Resistive load 5A at 12/24V AC/DC 5A at 12/24V AC/DC 5A at 12/24V AC/DC 5A at 100/120V AC 5A at 100/120V AC 5A at 100/120V AC Maximum Load Current 5A at 230/240V AC 5A at 230/240V AC 5A at 230/240V AC 0.3A — — Inductive load Inductive load Inductive load 2A at 12/24V AC/DC 2A at 12/24V AC/DC 2A at 12/24V AC/DC 3A at 100/120V AC 3A at 100/120V AC 3A at 100/120V AC 3A at 230/240V AC 3A at 230/240V AC 3A at 230/240V AC Built-in current External fuse External fuse limiting External fuse required: Short-circuit Protection required: required: — Yes resistor: Approx. 16A maximum 16A maximum 16A maximum 1A Minimum Switching Load — 10mA, 12V DC 10mA, 12V DC 10mA, 12V DC — — 100 mΩ maximum 100 mΩ maximum 100 mΩ maximum Initial Contact Resistance — — — (at 1A, 24V DC) (at 1A, 24V DC) (at 1A, 24V DC) 10 million operations 10 million operations 10 million operations Mechanical Life — — — (no load, 10Hz) (no load, 10Hz) (no load, 10Hz) 100,000 operations 100,000 operations 100,000 operations Electrical Life — (rated resistive load) (rated resistive load) (rated resistive load) — — 1800 operations/hour 1800 operations/hour 1800 operations/hour Analog Output Points — — — — — 2 Analog Output Range — — — — — 0 to 10V, 4-20mA Digital Resolution — — — — — 10 bits (0 to 1000V) Output Error — — — — — ±2.5% (of full scale) Output Impedance — — — — — 5kΩ Analog Value Conversion — — — — — 50ms Interval 10 m (twisted-pair Wire Length — — — — — shielded cable) Mechanical Load — 10Hz 10Hz 10Hz — — Electrical Load 10Hz — — — — — Resistive Load/Lamp Load 10Hz 2Hz 2Hz 2Hz — — Inductive Load 0.5Hz 0.5Hz 0.5Hz 0.5Hz — — www.IDEC.com 118 Barriers Communication Sensors Power Supplies Automation Software PLCs OI Touchscreens Switching Rate Output OI Touchscreens PLCs Automation Software Power Supplies Sensors Communication Barriers SmartRelay Series Programmable Logic Controllers General Item Specification Standard Horizontal 0 to 55°C Mounting Operating Cold: IEC60068-2-1 Temperature Hot: IEC60068-2-2 Vertical 0 to 55°C Mounting 1 Storage/Transportation Temperature –40 to +70°C — 2 Relative Humidity 10 to 95% RH IEC60068-2-30 Atmospheric Pressure 795 to 1080 hPa — Operating Condition No corrosive gas — Degree of Protection IP20 — 5 to 9Hz, amplitude 3.5mm Vibration Resistance IEC60068-2-6 2 9 to 150Hz, acceleration 9.8m/s (1G) 2 Shock Resistance 147m/s (15G) IEC60068-2-27 Drop Test 50mm IEC60068-2-31 Drop Test (packaged) 1m IEC60068-2-32 3 Emission Class B Group 1 EN55011 8kV air discharge Electrostatic Discharge IEC61000-4-2 4 6kV contact discharge Electromagnetic Fields 10V/m IEC61000-4-3 2kV (power line) Burst Pulses IEC61000-4-4 5 1kV (I/O signal line) 6 Energy Carriers Single Pulse (Surge) 1kV (power line) normal (FL1B-H12RCC, IEC61000-4-5 2kV (power line) common FL1B-B12RCC only) 2 0.5 to 2.5mm (one wire) Communication Cable — 2 0.5 to 1.5mm (two wires) 7 Terminal Style Finger-safe type — 1. No freezing 2. No condensation 3. Class A for AS-Interface communication module 4. 8kV (air discharge), 4kV (contact discharge) for AS-Interface communication module 5. 1kV (criteria A), 2kV (criteria B) for AS-Interface communication module 6. For protection against surge noise on DC power supply types (FL1D-H12RCE/B12RCE, FL1D-H12SND, FL1D-H12RCA/B12RCA), use surge absorbers, noise cut transformers, or noise filters. 7. Tightening torque 0.4 to 0.5 N·m AS-Interface Communication Module Specifications I/O Allocation Module Type AS-Interface slave module Input Output Slave Type Standard AS-Interface SmartRelay SmartRelay AS-Interface I/O code: 7 Output Data Bit D0 Input In Output Qm Input Data Bit D0 Profile ID code: F Output Data Bit D1 Input In+1 Output Qm+1 Input Data Bit D1 ID2 code: F Output Data Bit D2 Input In+2 Output Qm+2 Input Data Bit D2 Virtual input: 4 Output Data Bit D3 Input In+3 Output Qm+3 Input Data Bit D3 Input/Output Virtual output: 4 1. I/O point numbers “n” and “m” of the SmartRelay are automatically allocated by the base module according to the mounted position of the AS-Interface Voltage 30V DC (26.5 to 31.6V DC) AS-Interface communication module. 2. AS-Interface communication module is IP20 terminal type. Current Draw 70 mA maximum (AS-Interface) 3. AS-Interface cable is connected to the terminal block. 800-262-IDEC (4332) • USA & Canada 119 SmartRelay Series Programmable Logic Controllers Dimensions (mm) Base Module Expansion I/O Module, Communication Module I1 L+ M I2 I3 I4 I5 I6 I7 I8 L+ M 11 12 13 14 RUN/STOP 12 12 Q1 Q2 Q1 Q2 Q3 Q4 12 12 Q3 Q4 55 55 72 60 36 58 Mounting Hole Layout (Using Mounting Slides) +0.2 +0.2 53.5 –0.0 35.5–0.0 Expansion Expansion Expansion Module Module Module Base Module Communication Communication Communication Module Module Module +0.2 n × 35.5 2-ø4 Mounting Holes –0.0 Text Display Installation Mounting Hole Layout 119.5 + 0.5mm Mounting clip Mounting screws (tightening torque: 0.15 to 0.2 N·m) F1 F2 F3 F4 ESC OK 4 38.7 128.2 Mounting clip Panel (thickness: 1.5 to 4 mm) Waterproof Gasket www.IDEC.com 120 Barriers Communication Sensors Power Supplies Automation Software PLCs OI Touchscreens 98±0.3 35 4 90 86 35 4 90 78.5 + 0.5mm

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the FL1D-K2BM2?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

I/O Module Relays Input Module 24VDC 5mA FC3A-N32B4

product

I/O Module Relays Output Module FC3A-R161

product

I/O Module Relays Input Module 20mA DIN Rail FC4A-J4CN1

product

I/O Module Relays Input Module 24VDC 30mA DIN Rail FC4A-J8AT1

product

I/O Module Relays Input Module 20mA DIN Rail FC4A-J8C1

product

I/O Module Relays I/O Module DIN Rail FC4A-K1A1