Electronics Finder chervon right Manufacturers chervon right O chervon right OMRON AUTOMATION chervon right E3X-HD112M
About product Specifications Datasheet FAQ

OMRON AUTOMATION E3X-HD112M

Image of OMRON AUTOMATION E3X-HD112M

Description

Smart Fiber Amplifier 4-Pin
E3X-HD112M

Part Number

E3X-HD112M

Price

Request Quote

Manufacturer

OMRON AUTOMATION

Lead Time

Request Quote

Category

Sensors and Transducers »  Specialized Sensor

Specifications

Manufacturer

Omron Automation

Manufacturers Part #

E3X-HD112M

Industry Aliases

E3X-HD11 2M

Sub-Category

Specialized Sensors

Selling Alternatives

E3X-DA11-N, E3X-NA11, E3X-DA11-S, E3XDA11SES, E3X-NA212M, E3X-DA21-S2M, E3X-SD112M, E3X-SD212M, E3X-DA11, E3XDA11ATS

Factory Pack Quantity

1

Datasheet

pdf file

e3x-hd_ds_e_7_2_csm1012032.pdf

3892 KiB

Extracted Text

Light intensity Smart Fiber Amplifier Unit E3X-HD CSM_E3X-HD_DS_E_7_2 Easy and optimum settings for anyone Smart Fiber Amplifier Unit with Long-term Stable Detection • Equipped with Smart Tuning, which automatically configures the settings to their optimum values with the press of a single button. Highly usable design enables anyone to configure the settings easily. Detects dirt, vibrations, and LED deterioration, and automatically compensates the incident level and the light intensity. Unparalleled best-in-class power provides stable detections for low- reflective workpieces and large workpieces (equipped with GIGA RAY II). Refer to the Fiber Sensors Technical Guide and Safety Precautions on page 9. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Features Easy Indications Greater operability and visibility Visibility is improved with digital displays and visible indicators. are realized by a universal design New Concept: Visible Indicators LD DPC ST Operations Operation mode Flashing indicator Indicates that the Symbolic buttons are easy to remember anywhere even for operators overseas. indicator to prevent enables preventive optimum settings incorrect settings. maintenance. have been made. LD DPC ST O OUT U indicator T Threshold (green) Incident level (red) TUNE UP DOWN MODE L/D Compatibility for easy operation and incorrect operation prevention. Smart Tuning Smart tuning for the optimum settings with just one button. Buttons are arranged in a straight line. Smart Tuning Automatically configure the settings to their Pleasing operation even with gloves on. optimum values with the press of a single button. Hard to operate. With workpiece Without workpiece Settings are Finger gets caught. simultaneously completed. Conventional Models E3X-HD Sliding switches Pushbutton switches Incident level adjustment Arc Design with workpiece (no sliding switches) A strong accent line gives a Threshold setting Press only twice. (Set to intermediate value compact look to improve between the incident levels equipment design with and without a workpiece. ) Incident level adjustment without workpiece Stable Long-term stable detection with no maintenance Always ON Long-term stability APC Smart Power Control (AUTO POWER Maintenance-free operation by double compensation of light intensity CONTROL) and incident level With APC Automatically Without APC compensate light LED Vibration intensity Aged Dirt Time deterioration L L D D DPC DPC C ST ST Incident level Compen- Compen- Compen- O O Decreased U U DPC T T sated. sated. sated. LD DPC ST 5000 5000 09999 999999999999 No Maintenance No Maintenance O Target value Flashes when U Compensated Compensated (DYNAMIC POWER T (displayed compensation is 50009000 CONTROL) no longer possible. incident level) Automatically Smart Power DPC Setting value Control compensate (threshold value) incident level + Time Light intensity compensation Incident level compensation 1 E3X-HD Ordering Information Fiber Amplifier Units Standard models (Dimensions ➜ page 12) Models Appearance Connecting method NPN output PNP output Pre-wired (2 m) E3X-HD11 2M E3X-HD41 2M Wire-saving Connector E3X-HD6 E3X-HD8 M8 Connector E3X-HD14 E3X-HD44 Model for Sensor Communications Unit (Dimensions ➜ page 12) Appearance Model Applicable Sensor Communications Unit E3X-ECT E3X-HD0 E3X-CRT Accessories (sold separately) Wire-saving connectors (Required for models for Wire-saving Connectors.) Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately. * Protective stickers: provided. Type Appearance Cable length Number of conductors Models Master 3 E3X-CN11 Connector 2 m Slave 1 E3X-CN12 Connector Sensor I/O Connectors (Required for models with M8 Connectors.) Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately. Size Cable Appearance Cable type Models 2 m XS3F-M421-402-A Straight 5 m XS3F-M421-405-A M8 Standard 4-wire 2 m XS3F-M422-402-A L-shaped 5 m XS3F-M422-405-A Mounting Bracket DIN Track A Mounting Bracket is not provided with the Fiber Amplifier Unit and must be A Din Track is not provided with the Fiber Amplifier Unit and must be ordered ordered separately as required. separately as required. Appearance Model Quantity Appearance Type Models Quantity Shallow type, total length: 1 m PFP-100N Shallow type, total length: 0.5 m 1 PFP-50N E39-L143 1 Deep type, total length: 1 m PFP-100N2 End Plate Two End Plates are provided with the Sensor Communications Unit. End Plates are not provided with the Fiber Amplifier Unit and must be ordered separately as required. Appearance Model Quantity PFP-M 1 2 E3X-HD Ratings and Specifications Type Standard Model for Sensor Communications Unit *1 NPN E3X-HD11 E3X-HD6 E3X-HD14 output E3X-HD0 PNP E3X-HD41 E3X-HD8 E3X-HD44 output Connecting Wire-saving Connector for Sensor Pre-wired M8 Connector Item method Connector *2 Communications Unit Light source (wavelength) Red, 4-element LED (625 nm) Supplied from the connector through Power supply voltage 12 to 24 VDC ±10%, ripple (P-P) 10% max. the Sensor Communications Unit Normal mode 720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC) Power Eco ON 530 mW max. (Current consumption: 22 mA max. at 24 VDC, 44 mA max. at 12 VDC) consump tion 640 mW max. (Current consumption: 26 mA max. at 24 VDC, 53 mA max. Eco LO − at 12 VDC) Load power supply voltage: 26.4 VDC max., open-collector output Load current: Groups of 1 to 3 Amplifier Units: 100mA max., Groups of 4 to 16 Amplifier Units: 20mA max. Control output − Residual voltage:At load current of less than 10 mA: 1 V max., At load current of 10 to 100 mA: 2 V max. OFF current: 0.1 mA max. Power supply reverse polarity Power supply reverse polarity protection, output short-circuit Protection circuits protection and output short-circuit protection and output reverse polarity protection protection Super-high-speed NPN outputs: Operate or reset: 50 μs − mode (SHS) *3 PNP outputs: Operate or reset: 55 μs Response High-speed mode (HS) Operate or reset: 250 μs (default setting) time Standard mode (Stnd) Operate or reset: 1 ms Giga-power mode (GIGA) Operate or reset: 16 ms with E3X-CRT: 16 units Maximum connectable Units 16 units with E3X-ECT: 30 units Mutual interference prevention Possible for up to 10 units (optical communications sync) *3 Auto power control (APC) Always ON Power tuning, differential detection, DPC, timer (OFF-delay, ON-delay, or one-shot), Other functions zero reset, resetting settings, and Eco mode Ambient illumination Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. (Receiver side) Operating: Operating: Groups of 1 to 2 Amplifiers: 0 to 55°C, Groups of 1 to 2 Amplifiers: −25 to 55°C, Groups of 3 to 10 Amplifiers: 0 to 50°C, Groups of 3 to 10 Amplifiers: −25 to 50°C, Ambient temperature range Groups of 11 to 16 Amplifiers: 0 to 45°C, Groups of 11 to 16 Amplifiers: −25 to 45°C Groups of 17 to 30 Amplifiers: 0 to 40°C Storage: −30 to 70°C Storage: −30 to 70°C (with no icing or condensation) (with no icing or condensation) Ambient humidity range Operating and storage: 35% to 85% (with no condensation) Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute 10 to 150 Hz with a 0.7-mm double Vibration resistance 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, amplitude for 80 minutes each in X, Y, (destruction) Y, and Z directions and Z directions 2 150 m/s for 3 times each in X, Y, and 2 Shock resistance (destruction) 500 m/s for 3 times each in X, Y, and Z directions Z directions Degree of protection IEC 60529 IP50 (with Protective Cover attached) − Approx. 105 g/ Approx. 60 g/ Approx. 70 g/ Weight (packed state/unit only) Approx. 65 g/Approx. 25 g Approx. 65 g Approx. 20 g Approx. 25 g Case Polycarbonate (PC) Heat-resistant ABS (connector: PBT) Materials Cover Polycarbonate (PC) Cable PVC − Accessories Instruction Manual *1. The E3X-ECT EtherCAT Sensor Communications Unit and the E3X-CRT CompoNet Sensor Communications Unit can be used. *2. Use either the E3X-CN11 (master connector, 3 conductors) or the E3X-CN12 (slave connector, 1 conductor). *3. The communications function and mutual interference prevention function are disabled when the detection mode is set to Super-high-speed mode (SHS). When including E3X-DA-S with activated power tuning, mutual interference prevention is possible for up to 6 units. When including E3X-MDA with activated power tuning, mutual interference prevention is possible for up to 5 units. 3 E3X-HD Sensing Distances Threaded Models Sensing distance (mm) Sensing Sensing direction Size Model High-speed Super-high- method Giga mode Standard mode mode speed mode E32-T11N 2M 2,000 1,000 700 280 Right-angle E32-LT11N 2M 4,000 * 3,500 2,300 920 Through-beam M4 E32-T11R 2M 2,000 1,000 700 280 Straight E32-LT11 2M 4,000 * 4,000 * 2,700 1,080 E32-LT11R 2M 4,000 * 3,500 2,300 920 E32-C31N 2M 110 50 46 14 M3 E32-C21N 2M 290 130 90 39 Right-angle M4 E32-D21N 2M 840 350 240 100 E32-C11N 2M 780 350 320 100 M6 E32-LD11N 2M 840 350 240 100 E32-D21R 2M 140 60 40 16 Reflective M3 E32-C31 2M 330 150 100 44 E32-C31M 1M M4 E32-D211R 2M 140 60 40 16 Straight E32-D11R 2M 840 350 240 100 E32-CC200 2M 1,400 600 400 180 M6 E32-LD11 2M 860 360 250 110 E32-LD11R 2M 840 350 240 100 * The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Cylindrical Models Sensing distance (mm) Sensing Size Sensing direction Model High-speed Super-high- method Giga mode Standard mode mode speed mode 1 dia. E32-T223R 2M 450 250 150 60 1.5 dia. Top-view E32-T22B 2M 680 400 220 90 Through-beam E32-T12R 2M 2,000 1,000 700 280 3 dia. Side-view E32-T14LR 2M 750 450 260 100 1.5 dia. E32-D22B 2M 140 60 40 16 1.5 dia. + E32-D43M 1M 28 12 8 4 0.5 dia. E32-D22R 2M 140 60 40 16 Reflective Top-view 3 dia. E32-D221B 2M 300 140 90 40 E32-D32L 2M 700 300 200 90 3 dia. + E32-D33 2M 70 30 20 8 0.8 dia. Flat Models Sensing distance (mm) Sensing Sensing direction Model High-speed Super-high- method Giga mode Standard mode mode speed mode Top-view E32-T15XR 2M 2,000 1,000 700 280 Through-beam Side-view E32-T15YR 2M 750 450 260 100 Flat-view E32-T15ZR 2M Top-view E32-D15XR 2M 840 350 240 100 Reflective Side-view E32-D15YR 2M 200 100 52 24 Flat-view E32-D15ZR 2M Sleeve Models Sensing distance (mm) Sensing Sensing direction Model High-speed Super-high- method Giga mode Standard mode mode speed mode E32-T24R 2M 170 100 50 20 Side-view E32-T24E 2M 450 250 150 60 Through-beam E32-T33 1M 150 90 50 20 Top-view E32-T21-S1 2M 510 300 170 68 E32-TC200BR 2M 2,000 1,000 700 280 E32-D24R 2M 70 30 20 8 Side-view E32-D24-S2 2M 120 53 45 14 E32-D43M 1M 28 12 8 4 E32-D331 2M 14 6 4 2 E32-D33 2M 70 30 20 8 E32-D32-S1 0.5M Reflective 63 27 18 7 E32-D31-S1 0.5M Top-view E32-DC200F4R 2M 140 60 40 16 E32-D22-S1 2M 250 110 72 30 E32-D21-S3 2M E32-DC200BR 2M 840 350 240 100 E32-D25-S3 2M 250 110 72 30 4 E3X-HD Small-spot, Reflective Models Sensing distance (mm) Center Type Spot diameter distance Model High-speed Super-high- Giga mode Standard mode (mm) mode speed mode 0.1 to 0.6 dia. 6 to 15 E32-C42 1M+E39-F3A Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. Variable spot 0.3 to 1.6 dia. 10 to 30 E32-C42 1M+E39-F17 Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. E32-C31 2M+E39-F3C Parallel light 4 dia. 0 to 20 Spot diameter of 4 mm max. at 0 to 20 mm. E32-C31N 2M+E39-F3C 0.1 dia. 5 E32-C42S 1M Spot diameter of 0.1 mm at 5 mm. Integrated lens 6 dia. 50 E32-L15 2M Spot diameter of 6 mm at 50 mm. 0.1 dia. E32-C41 1M+E39-F3A-5 Spot diameter of 0.1 mm at 7 mm. 7 E32-C31 2M+E39-F3A-5 0.5 dia. Spot diameter of 0.5 mm at 7 mm. E32-C31N 2M+E39-F3A-5 0.2 dia. E32-C41 1M+E39-F3B Spot diameter of 0.2 mm at 17 mm. Small-spot 17 E32-C31 2M+E39-F3B 0.5 dia. Spot diameter of 0.5 mm at 17 mm. E32-C31N 2M+E39-F3B E32-CC200 2M+E39-F18 3 dia. 50 Spot diameter of 3 mm at 50 mm. E32-C11N 2M+E39-F18 High-power Beam Models Sensing distance (mm) Aperture Type Sensing direction Model High-speed Super-high- angle Giga mode Standard mode mode speed mode Right-angle 15° E32-LT11N 2M 4,000 *2 3,500 2,300 920 10° E32-T17L 10M 20,000 *1 20,000 *1 20,000 *1 8,000 Through-beam models with Top-view E32-LT11 2M 4,000 *2 4,000 *2 2,700 1,080 15° integrated lens E32-LT11R 2M 4,000 *2 3,500 2,300 920 Side-view 30° E32-T14 2M 4,000 *2 4,000 *2 4,000 *2 1,800 12° E32-T11N 2M+E39-F1 4,000 *2 4,000 *2 4,000 *2 2,000 Right-angle 6° E32-T11N 2M+E39-F16 4,000 *2 4,000 *2 4,000 *2 3,600 12° E32-T11R 2M+E39-F1 4,000 *2 4,000 *2 4,000 *2 2,000 Top-view 6° E32-T11R 2M+E39-F16 4,000 *2 4,000 *2 4,000 *2 3,600 Side-view 60° E32-T11R 2M+E39-F2 1,450 800 500 200 12° E32-T11 2M+E39-F1 4,000 *2 4,000 *2 4,000 *2 1,860 Top-view 6° E32-T11 2M+E39-F16 4,000 *2 4,000 *2 4,000 *24,000 *2 Side-view 60° E32-T11 2M+E39-F2 2,300 1,320 860 320 12° E32-T51R 2M+E39-F1 4,000 *2 4,000 *2 3,900 1,500 Through-beam Top-view models with 6° E32-T51R 2M+E39-F16 4,000 *2 4,000 *2 4,000 *24,000 *2 lenses Side-view 60° E32-T51R 2M+E39-F2 1,400 720 500 200 12° E32-T81R-S 2M+E39-F1 4,000 *2 4,000 *2 2,700 1,000 Top-view 6° E32-T81R-S 2M+E39-F16 4,000 *2 4,000 *2 4,000 *2 1,800 Side-view 60° E32-T81R-S 2M+E39-F2 1,000 550 360 140 12° E32-T61-S 2M+E39-F1 4,000 *2 4,000 *2 4,000 *2 1,800 Top-view 6° E32-T61-S 2M+E39-F16 4,000 *2 4,000 *2 4,000 *2 3,100 Side-view 60° E32-T61-S 2M+E39-F2 1,680 900 600 240 12° E32-T51 2M+E39-F1-33 4,000 *2 4,000 *2 2,300 1,400 Top-view 6° E32-T51 2M+E39-F16 4,000 *2 4,000 *2 4,000 *24,000 *2 Reflective models with Top-view 4° E32-D16 2M 40 to 2,800 40 to 1,400 40 to 900 40 to 480 integrated lens *1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm. *2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Narrow View Models Sensing distance (mm) Sensing Sensing direction Aperture angle Model High-speed Super-high- method Giga mode Standard mode mode speed mode E32-A03 2M 1.5° 3,220 1,780 1,200 500 E32-A03-1 2M 3.4° E32-A04 2M 1,280 680 450 200 Through-beam Side-view E32-T24SR 2M 4,000 * 2,200 1,460 580 4° E32-T24S 2M 4,000 * 2,600 1,740 700 E32-T22S 2M 4,000 * 3,800 2,500 1,000 * The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. 5 E3X-HD Models for Detection without Background Interference Sensing distance (mm) Sensing method Sensing direction Model High-speed Super-high- Giga mode Standard mode mode speed mode E32-L16-N 2M 0 to 15 0 to 12 Flat-view Limited-reflective E32-L24S 2M 0 to 4 Side-view E32-L25L 2M 5.4 to 9 (center 7.2) Transparent Object Detection (Retro-reflective Models) Sensing distance (mm) Sensing method Feature Size Model High-speed Super-high- Giga mode Standard mode mode speed mode E32-C31 2M Film detection M3 +E39-F3R 250 200 --- +E39-RP37 Square --- E32-R16 5M 150 to 1,500 Retro-reflective Threaded E32-R21 2M 10 to 250 M6 E32-LR11NP 2M Hex-shaped 1,350 1,200 1,000 550 +E39-RP1 Transparent Object Detection (Limited-reflective Models) Sensing distance (mm) Sensing method Feature Sensing direction Model High-speed Super-high- Giga mode Standard mode mode speed mode Small size 0 to 4 E32-L24S 2M Standard E32-L16-N 2M 0 to 15 0 to 12 Flat-view Glass substrate E32-A08 2M 10 to 20 --- alignment, 70°C Limited-reflective Standard/long-distance E32-A12 2M 12 to 30 --- Side-view form Side-view E32-L25L 2M 5.4 to 9 (center 7.2) Glass substrate Top-view E32-A09 2M 15 to 38 --- mapping, 70°C Chemical-resistant, Oil-resistant Models Sensing distance (mm) Sensing Type Sensing direction Model High-speed Super-high- method Giga mode Standard mode mode speed mode Oil-resistant Right-angle E32-T11NF 2M 4,000 *14,000 *14,000 *12,200 E32-T12F 2M 4,000 *14,000 *14,000 *11,600 Top-view Through- Chemical/oil-resistant E32-T11F 2M 4,000 *14,000 *12,600 1,000 beam Side-view E32-T14F 2M 1,400 800 500 200 Chemical/oil-resistant at Top-view E32-T51F 2M 4,000 *1 2,800 1,800 700 150°C Semiconductors: Cleaning, 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), developing, and etching; E32-L11FP 5M 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) 60°C Semiconductors: Resist 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), Reflective Top-view E32-L11FS 5M stripping; 85°C 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) Chemical/oil-resistant E32-D12F 2M --- *2190 130 60 Chemical-resistant cable E32-D11U 2M 840 350 240 100 *1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. *2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin. Bending-resistant Models Sensing distance (mm) Sensing method Size Model High-speed Super-high- Giga mode Standard mode mode speed mode 1.5 dia. E32-T22B 2M 680 400 220 90 M3 E32-T21 2M Through-beam M4 E32-T11 2M 2,500 1,350 900 360 Square E32-T25XB 2M 500 300 170 70 1.5 dia. E32-D22B 2M 140 60 40 16 M3 E32-D21 2M 3 dia. E32-D221B 2M Reflective 300 140 90 40 M4 E32-D21B 2M M6 E32-D11 2M 840 350 240 100 Square E32-D25XB 2M 240 100 60 30 6 E3X-HD Heat-resistant Models Sensing distance (mm) Sensing method Size Model High-speed Super-high- Giga mode Standard mode mode speed mode 100°C E32-T51R 2M 1,600 800 560 225 150°C E32-T51 2M 2,800 1,500 1,000 400 Through-beam 200°C E32-T81R-S 2M 1,000 550 360 140 350°C E32-T61-S 2M 1,680 900 600 240 100°C E32-D51R 2M 670 280 190 80 150°C E32-D51 2M 1,120 450 320 144 200°C E32-D81R-S 2M 420 180 120 54 E32-A08H2 2M 10 to 20 --- Reflective 300°C E32-A09H2 2M 20 to 30 (center 25) --- E32-D611-S 2M 350°C 420 180 120 54 E32-D61-S 2M 400°C E32-D73-S 2M 280 120 80 36 Area Detection Models Sensing distance (mm) Sensing method Type Sensing width Model High-speed Super-high- Giga mode Standard mode mode speed mode E32-T16PR 2M 3,100 1,700 1,120 440 11 mm Through-beam Area E32-T16JR 2M 2,750 1,500 960 380 30 mm E32-T16WR 2M 4,000 * 2,600 1,700 680 Reflective Array 11 mm E32-D36P1 2M 700 300 200 90 * The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Liquid-level Detection Models Sensing distance (mm) Sensing method Tube diameter Feature Model High-speed Super-high- Giga mode Standard mode mode speed mode 3.2, 6.4, Stable residual Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm, E32-A01 5M or 9.5 dia. quantity detection Recommended wall thickness: 1 mm Tube-mounting Mounting at Applicable tube: Transparent tube with a diameter of 8 to 10 mm, 8 to 10 dia. E32-L25T 2M multiple levels Recommended wall thickness: 1 mm No restrictions Large tubes E32-D36T 5M Applicable tube: Transparent tube (no restrictions on diameter) Liquid contact (heat-resistant --- --- E32-D82F1 4M Liquid-contact type up to 200°C) Vacuum-resistant Models Sensing distance (mm) Sensing method Heat-resistant temperature Model High-speed Super-high- Giga mode Standard mode mode speed mode E32-T51V 1M 720 400 260 100 120°C Through-beam E32-T51V 1M+E39-F1V 2,000 * 2,000 * 1,360 520 200°C E32-T84SV 1M 1,760 950 640 260 * The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm. Models for FPD, Semiconductors, and Solar Cells Sensing distance (mm) Operating Sensing method Application Model High-speed Super-high- temperature Giga mode Standard mode mode speed mode Glass presence detection 0 to 15 0 to 12 E32-L16-N 2M 70°C E32-A08 2M 10 to 20 --- Glass substrate alignment 300°C E32-A08H2 3M E32-A12 2M 12 to 30 --- 70°C E32-A09 2M 15 to 38 --- Limited-reflective Glass substrate mapping 300°C E32-A09H2 2M 20 to 30 (center 25) --- Wet processes: Cleaning, Resist 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 60°C E32-L11FP 5M developing and etching 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) Wet process: 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 85°C E32-L11FS 5M Resist stripping 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) E32-A03 2M 3,220 1,780 1,200 500 E32-A03-1 2M Through-beam Wafer mapping 70°C 1,280 680 450 200 E32-A04 2M E32-T24SR 2M 4,000 * 2,200 1,460 580 E32-T24S 2M 4,000 * 2,600 1,740 700 * The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. 7 E3X-HD I/O Circuit Diagrams NPN Output Operation L/D Models Timing chart Output circuit mode indicators Incident light No incident light OUT indicator (orange) Display OUT indicator Lit Brown 1 (orange) Not lit Light-ON Load Output ON L lit. Black 4 transistor OFF Control output Load Set Photoelectric 12 to (e.g., relay) Reset Sensor main 24 VDC (Between blue and E3X-HD11 circuit black leads) E3X-HD6 Incident light E3X-HD14 No incident light Blue 3 OUT indicator Lit (orange) Not lit Dark-ON Output ON D lit. • M8 Connector Pin Arrangement transistor OFF 2 4 Load Set 1 3 (e.g., relay) Reset Note: Pin 2 is not used. (Between blue and black leads) PNP Output Operation L/D Models Timing chart Output circuit mode indicators Incident light No incident light OUT indicator (orange) Display OUT indicator Lit Brown 1 (orange) Not lit Light-ON Output ON L lit. transistor OFF Control output Load Set Photoelectric Black 12 to 4 (e.g., relay) Reset Sensor main (Between blue and 24 VDC E3X-HD41 circuit black leads) Load E3X-HD8 E3X-HD44 Incident light Blue 3 No incident light OUT indicator Lit Not lit (orange) Dark-ON Output ON D lit. • M8 Connector Pin Arrangement 2 4 OFF transistor 1 3 Load Set Note: Pin 2 is not used. Reset (e.g., relay) (Between blue and black leads) Plug (Sensor I/O Connector) ON delay OFF delay One-shot Terminal number Wire color Incident light Incident light Incident light 4 2 1 Brown No incident light No incident light No incident light T T T 2 White 3 1 3 Blue ON ON ON Light-ON Light-ON 4 Light-ON Black OFF OFF OFF T T T ON ON ON XS3F-M421-402-A XS3F-M422-402-A Dark-ON Dark-ON Dark-ON OFF OFF XS3F-M421-405-A XS3F-M422-405-A OFF Wire color Connection pin Application Note: Timing Charts for Timer Settings (T: Set Time) Brown 1 Power supply (+V) White 2 --- Blue 3 Power supply (0 V) Black 4 Output Note: Pin 2 is not used. Nomenclature [L/D Indicator] [DPC Indicator] [ L/D Button] Indicates the setting status: Turns ON when Dynamic Power Control is effective. Use to switch between Light-ON (L) or Dark-ON (D). Light-ON (L) and Dark-ON (D). [OUT Indicator] [ST Indicator] Turns ON when Turns ON when Smart Tuning the output is ON. is in progress. Threshold Level Incident Level [ MODE Button] Green digital display Red digital display Use to switch between Detection Mode and Setting Mode. [ TUNE Button] [+−UP/DOWN Button] Automatically sets the emitter Used to fine-tune the threshold power and set values. or change set values. 8 E3X-HD Safety Precautions Refer to the Fiber Sensors Technical Guide for precautions that apply to all Fiber Sensors. Precautions for Correct Use Warning • Be sure to mount the unit to the DIN track until it clicks. This product is not designed or rated for ensuring 2 • Use an extension cable with a minimum thickness of 0.3 mm and safety of persons either directly or indirectly. less than 100 m long. Do not use it for such purposes. • Do not subject the cable to more than the following forces. Pull: 40 N; torque: 0.1 N⋅m; pressure: 20 N; bending: 29.4 N Do not use the product with voltage in excess of the • The Sensor is ready to operate 200 ms after the power supply is rated voltage. turned ON. Excess voltage may result in malfunction or fire. • When using Amplifier Units with Wire-saving Connectors, attach the protective stickers (provided with E3X-CN-series Connectors) Never use the product with AC power supply. on the unused power pins to prevent electrical shock and short Otherwise, explosion may result. circuiting. When using Amplifier Units with Connectors for Communications Units, attach the protective caps (provided with E3X-CRT/ECT Sensor Communications Unit). Precautions for Safe Use Amplifier Unit with Amplifier Unit with Connector The following precautions must be observed to ensure safe Wire-saving Connector for Communications Unit operation of the product. Doing so may cause damage or fire. 1. Do not install the product in the following locations. • Locations subject to direct sunlight • Locations subject to condensation due to high humidity Protective Sticker • Locations subject to corrosive gas • Locations subject to vibration or mechanical shocks Power Supply Protective Cap Connecting Terminal exceeding the rated values • Locations subject to exposure to water, oil, chemicals • Output pulses may occur when the power supply is turned OFF. Turn • Locations subject to stream OFF the power supply to the load or load line first. • Locations subjected to strong magnetic field or electric field • Excessive incident light cannot be sufficiently handled by the 2. Do not use the product in environments subject to flammable mutual interference prevention function and may cause or explosive gases. malfunction. To prevent this, set a higher threshold level. 3. To secure the safety of operation and maintenance, do not • Make sure that the power supply is turned OFF before connecting, install the product close to high-voltage devices and power separating, or adding Amplifier Units. devices. • Do not pull on or apply excessive pressure or force to the Fiber Unit 4. High-Voltage lines and power lines must be wired separately when it is attached to the Amplifier Unit. from this product. Wiring them together or placing them in the same duct may cause induction, resulting in malfunction or • The E3X-MC11, E3X-MC11-SV2 and E3X-MC11-S Mobile damage. Consoles cannot be used. 5. Do not apply load exceeding the ratings. Otherwise, damage or • Mutual interference prevention on the E3X-HD Series does not fire may result. function among the E3NX-FA, E3X-DA-N, E3X-SD, or E3X-NA 6. Do not short the load. Otherwise, damage or fire may result. Fiber Amplifier Units. 7. Connect the load correctly. Mutual interference prevention on the E3X-HD Series does 8. Do not miswire such as the polarity of the power supply. function among the E3X-DA-S and E3X-MDA Fiber Amplifier Units. 9. Do not use the product if the case is damaged. • The E3X-CRT and E3X-ECT Sensor Communications Unit can be 10. Burn injury may occur. The product surface temperature rises used with the E3X-HD0, but the E3X-DRT21-S and E3NW-ECT depending on application conditions, such as the ambient Sensor Communications Units cannot be used. temperature and the power supply voltage. Attention must be • Always keep the protective cover in place when using the Amplifier paid during operation or cleaning. Unit. 11. When setting the Sensor, be sure to check safety, such as by • Do not use thinner, benzine, acetone, and kerosene for cleaning. stopping the equipment. 12. Be sure to turn off the power supply before connecting or For technical information and product FAQs, refer to the disconnecting wires. Technical Guide on your OMRON website. 13. Do not attempt to disassemble, repair, or modify the product Unit in any way. 14. When disposing of the product, treat it as industrial waste. 15. Do not use the Sensor in water, rainfall, or outdoors. 9 E3X-HD Mounting the Fiber Amplifier Units Mounting Fiber Units „ Mounting on DIN Track „ Use Fiber Cutter Cut a thin fiber as follows. 1. Let the hook on the Amplifier For standard fibers, insert to the desired cutting position and cut. Unit’s Fiber Unit connection side catch the track and push the unit Thin Fiber The fiber is until it clicks. Attachment (E39-F9) shipped loosely 1. tightened as Fiber Unit Connection Side Hook shown in the „ Removing from DIN Track figure at the right. Loosely tighten. 2 1 1. Push the unit in the direction 1. 2. Lift it up in the direction 2. Note: Refer to I/O Circuit Diagrams Adjust the fiber or check the side of the unit for to the desired 2. wire color and role indications. length and fully tighten. „ Mounting Amplifier Units in Group (Connector Type Models) Fiber Cutter 1. Mount the Fiber Amplifier units one E39-F4 Insert the Fiber DIN Track at a time onto the DIN track and 3. Unit into E39-F4 Thin-diameter push them until they click. and cut it. 2 Fiber Unit Hole × 2 2. Slide the Fiber Amplifier units in the Standard Fiber Unit Hole direction 2. (dia. 2.2 mm) × 3 3. Use End Plates (PFP-M: separately sold) at the both ends of About 0.5 mm the grouped Fiber Amplifier units to Finished state. prevent them from separating due Insertion direction 4. (Correctly cut to vibration or other cause. end) Note: The insertion direction into the Fiber 4. Tighten the screw on the End Amplifier Unit is shown in the above figure. 4 3 Plates using a driver. „ Mount Fiber Unit 1. Open the protective cover. Lock Lever 2. Raise the lock lever. Tighten the screw while pressing the End Plate. Lock Release 3. Insert the Fiber Unit in the fiber Protective 4 • Under environments such as vibration, use an end plates even with a single Cover unit hole to the bottom. 2 1 Fiber Amplifier Unit. 4. Return the lock lever to the • The maximum numbers of connectable Amplifier Units are given in the original position and fix the 3 following table. Fiber Unit. Maximum Fiber Unit Maximum number of • When mounting a coaxial reflective number of mutual Fiber Unit, insert the single-core interconnected interference Fiber Unit to the upper hole (Emitter prevention side) and the multi-core Fiber Unit to E3X-HD series standard models the lower hole (Receiver side). 16 10 (E3X-HD11/HD41/HD6/HD8) Single Core The cables for the Single-core Fiber Multi Core Units (Emitters) have identification With E3X-ECT 30 10 E3X-HD0 marks. Refer to the dimensions With E3X-CRT 16 10 diagrams for details. • The mutual interference prevention function cannot be used if the detection • When removing the Fiber Unit, follow the above steps in reverse order. mode is set to super-high-speed mode (SHS). To maintain the characteristics of the Fiber Unit, make sure the lock is • If Units are to be connected, the allowable ambient temperature will change released before removing the Fiber Unit. with the number of Units that are connected. Check the Ratings and Specifications. • Always turn OFF the power before connecting or disconnecting Units. 10 E3X-HD (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Fiber Amplifier Units Pre-wired Amplifier Units E3X-HD11 E3X-HD41 DPC indicator L/D indicator ST indicator 21.7 27.1 Vinyl-insulated round cable, 4 dia., 3 conductors Incident level 2 (conductor cross-section: 0.2 mm , insulation diameter: 1.1 mm), OUT indicator red digital display standard cable length: 2 m Threshold level green digital display Minimum bending radius: 12 mm 10 10 DIN track mounting With Mounting Braket Attached 5.1 146.9 146.9 Note: When using E39-L143 Mounting 170° (max. value with cover open) Brackets, there will be small gaps 104. 104.88 between the Amplifier Units if they (max. value 5.1 with cover are mounted side by side. open) Two, 49.2 2.4-dia. 4.5 holes 33.5 33.5 33.5 33.5 (16.5) (16.5) 3.4 3.4 12.7 12.7 Optical 5.65 Two, 3.2-dia. 4.3 20.5 communications Optical communications (9.4) holes (37.9) (20.3) 20.5 16 71. 71.88 71. 71.88 E39-L143 Mounting Bracket PFP-@N DIN Track Mouting Holes (sold separately, SUS304) (sold separately) Fiber Attachment (E39-F9) attached Two-M3 4.4 3.4 10.3 16 29.9 16 Amplifier Units with Wire-saving Connectors E3X-HD6 E3X-HD8 DPC indicator L/D indicator ST indicator 21.7 27.1 Incident level OUT indicator red digital display Threshold level green digital display 10 10 DIN track mounting With Mounting Braket Attached 5.1 146.9 146.9 Note: When using E39-L143 Mounting 170° (max. value with cover open) Brackets, there will be small gaps between the Amplifier Units if they 5.1 104. 104.88 are mounted side by side. (max. value with cover open) Two, 49.2 2.4-dia. A * A * 4.5 holes 33.5 33.5 33.5 33.5 (16.5) (16.5) 3.4 3.4 (13) (13) Optical 5.65 20.5 Two, 3.2-dia. 4.3 communications (9.4) holes (37.9) (20.3) 20.5 16 71. 71.88 71. 71.88 PFP-@N DIN Track E39-L143 Mounting Bracket (sold separately) (sold separately, SUS304) Fiber Attachment (E39-F9) attached Mouting Holes 4.4 3.4 Two-M3 10.3 29.9 16 16 * The cable diameters are as follows: E3X-CN11 (3 conductors) 4.0 dia. E3X-CN12 (1 conductor) 2.6 dia. 11 E3X-HD Amplifier Units with M8 Connectors E3X-HD14 E3X-HD44 DPC indicator L/D indicator ST indicator 21.7 27.1 Incident level OUT indicator red digital display Threshold level green digital display 10 10 DIN track mounting With Mounting Braket Attached 5.1 146.9 146.9 Note: When using E39-L143 Mounting 170° (max. value with cover open) Brackets, there will be small gaps between the Amplifier Units if they 5.1 are mounted side by side. 104. 104.88 (max. value with cover open) Two, 49.2 2.4-dia. A * A * 4.5 holes 33.5 33.5 33.5 33.5 (16.5) (16.5) 3.4 3.4 12.7 12.7 Optical M8 connector Two, 3.2-dia. 5.65 20.5 4.3 communications holes (9.4) (37.9) (20.3) 11.2 16 20.5 71. 71.88 71. 71.88 PFP-@N DIN Track E39-L143 Mounting Bracket (sold separately) (sold separately, SUS304) Fiber Attachment (E39-F9) attached Mouting Holes 4.4 3.4 Two-M3 10.3 29.9 16 16 * The cable diameters are as follows: E3X-CN11 (3 conductors) 4.0 dia. E3X-CN12 (1 conductor) 2.6 dia. Amplifier Unit with Connector for Sensor Communications Unit E3X-HD0 DPC indicator L/D indicator ST indicator 21.7 27.1 OUT indicator Incident level red digital display Threshold level green digital display 13. 13.88 11.5 10 DIN track mounting 100° (max. value with cover open) 103.5 104. 104.88 5.1 71.8 (max. value with cover Two, open) 2.4-dia. holes 4.5 33.5 33.5 (16.5) 3.4 9.9 5.65 20.5 3.4 (37.9) (39.3) 90. 90.88 Optical communications PFP-@N DIN Track (sold separately) Fiber Attachment (E39-F9) attached Refer to E32 Series for details on Fiber Units. 12 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2016.6 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2016 All Right Reserved.

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the E3X-HD112M?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Floatless Level Switch 8-Pin 61F-HSLAC100

product

Floatless Level Switch 8-Pin 61F-HSLAC110

product

Floatless Level Switch 8-Pin 61F-HSLAC115

product

Floatless Level Switch 8-Pin 61F-HSLAC220

product

Floatless Level Switch 8-Pin 61F-HSLAC24

product

Floatless Level Switch 8-Pin 61F-UHSAC100