Electronics Finder chervon right Manufacturers chervon right O chervon right OMRON AUTOMATION chervon right E5CS-R1KJU-WAC100-240
About product Specifications Datasheet FAQ

OMRON AUTOMATION E5CS-R1KJU-WAC100-240

Image of OMRON AUTOMATION E5CS-R1KJU-WAC100-240

Description

Simple Functions in DIN 48 x 48 mm-Size Plug-in Temperature Controllers
E5CS-R1KJU-WAC100-240

Part Number

E5CS-R1KJU-WAC100-240

Price

Request Quote

Manufacturer

OMRON AUTOMATION

Lead Time

Request Quote

Category

Thermal Management »  Misc Products

Specifications

Manufacturer

Omron Automation

Manufacturers Part #

E5CS-R1KJU-WAC100-240

Lead Time

4 Week Lead Time

Industry Aliases

E5CS-R1KJU-WAC100240

Sub-Categories

Miscellaneous Tools and Supplies

Factory Pack Quantity

1

Datasheet

pdf file

e5cs_ds_e_5_3_csm211.pdf

1134 KiB

Extracted Text

Temperature Controllers E5CS CSM_E5CS_DS_E_5_3 Simple Functions in DIN 48 × 48 mm-size Plug-in Temperature Controllers • Easy setting using DIP switch. • Models with two alarms added to Series, ideal for applications requiring alarms. • Universal-input (thermocouple/platinum resistance thermometer) models also available. • Clearly visible digital display with character height of 13.5 mm. • RoHS compliant. Refer to Safety Precautions for All Temperature For the most recent information on models that have been certified for Controllers. safety standards, refer to your OMRON website. Refer to E5CS/E5CSV Operation for operating procedures. Model Number Structure ■ Model Number Legend Plug-in Models E5CS-@@@@U-W 1 2 3 45 6 3 1. Control Outputs 3. Input 4. Power Supply Voltage R: Relay KJ: Thermocouple Blank: 100 to 240 VAC Q: Voltage for driving SSR P: Platinum resistance thermometer D: 24 VAC/VDC 2. Alarm Outputs G: Thermistor 5. Terminal Shape Blank: No alarm T: Thermocouple/platinum resistance U: Plug-in thermometer (universal-input) 1: 1 alarm 6. Case Color 2: 2 alarms W: Light gray Note: A functional explanation is provided here for illustration, but models are not necessarily available for all possible combinations. Refer to Ordering Information when ordering. Examples • Relay control output, without alarm, thermocouple input, plug-in construction, light gray case: E5CS-RKJU-W • Relay control output, one alarm output, platinum resistance thermometer input, plug-in construction, light gray case: E5CS-R1PU-W 1 E5CS Ordering Information ■ List of Models Case Color: Light Gray, Thermocouple or Platinum Resistance Thermometer, Power Supply Voltage: 100 to 240 VAC Size Type Control Alarms Outputs Model with Model with platinum modes thermocouple resistance thermometer E5CS-U Plug-in ON/OFF or 0 Relay E5CS-RKJU-W E5CS-RPU-W PID 48 × 48 mm Voltage (for driving SSR) E5CS-QKJU-W E5CS-QPU-W 1 Relay E5CS-R1KJU-W E5CS-R1PU-W Voltage (for driving SSR) E5CS-Q1KJU-W E5CS-Q1PU-W Case Color: Light Gray, Thermocouple or Platinum Resistance Thermometer, Power Supply Voltage: 24 VAC/VDC Size Type Control Alarms Outputs Model with Model with platinum modes thermocouple resistance thermometer E5CS-U Plug-in ON/OFF or 0 Relay E5CS-RKJDU-W E5CS-RPDU-W PID 48 × 48 mm Voltage (for driving SSR) E5CS-QKJDU-W --- 1 Relay E5CS-R1KJDU-W E5CS-R1PDU-W Voltage (for driving SSR) E5CS-Q1KJDU-W --- Case Color: Light Gray, Thermistor or Universal-input, Power Supply Voltage: 100 to 240 VAC Size Type Control Alarms Outputs Model with thermistor Model with universal- modes input (thermocouple and platinum resistance thermometer) E5CS-U Plug-in ON/OFF or 0 Relay E5CS-RGU-W E5CS-RTU-W PID 48 × 48 mm Voltage (for driving SSR) E5CS-QGU-W E5CS-QTU-W 1 Relay E5CS-R1GU-W E5CS-R1TU-W Voltage (for driving SSR) E5CS-Q1GU-W E5CS-Q1TU-W 2 Relay --- E5CS-R2TU-W (See note.) Voltage (for driving SSR) E5CS-Q2TU-W Note: There is no alarm output 2 mode switch. The default setting for alarm output 2 is for the upper limit alarm mode. To change the setting, change the alarm type for alarm output 2 in initial setting level 5. For details, refer to the “E5CSV/E5CS-U Digital Temperature Controller User’s Manual” (Cat. No. H140-E1-01). Case Color: Light Gray, Thermistor, Power Supply Voltage: 24 VAC/VDC Size Type Control Alarms Outputs Model with thermistor modes E5CS-U Plug-in ON/OFF or 0 Relay E5CS-RGDU-W PID 48 × 48 mm 1 E5CS-R1GDU-W ■ Accessories (Order Separately) Socket without Alarm (8 Pins) Socket with Alarm (11 Pins) Type Model Type Model Front Connecting Socket P2CF-08 Front Connecting Socket P2CF-11 Back Connecting Socket (flush mounting) P3G-08 Back Connecting Socket (flush mounting) P3GA-11 Front Connecting Socket (with finger protection) P2CF-08-E Front Connecting Socket (with finger protection) P2CF-11-E Finger Safe Terminal Cover for P3G Y92A-48G Finger Safe Terminal Cover for P3G Y92A-48G Protective Cover Type Model Hard Protective Cover Y92A-48B 2 E5CS Specifications ■ Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage Power consumption 100 to 240 VAC: 5 VA 24 VAC: 3 VA, 24 VDC: 2 W Sensor input Thermocouple: K, J, L Platinum resistance thermometer: Pt100, JPt100 Thermistor: E52-THE@@ Universal-input (thermocouple/platinum resistance thermometer): K, J, L, T, U, N, R, Pt100, JPt100 Control Relay output SPDT, 250 VAC, 3 A (resistive load) output Voltage output 12 VDC, 21 mA (with short-circuit protection circuit) (for driving the SSR) Control method ON/OFF or 2-PID (with automatic PID parameter setting function) Alarm output SPST-NO, 250 VAC, 1A (resistive load) Setting method Digital setting using front panel keys Indication method 7-segment digital display (character height: 13.5 mm) and deviation indicators Other functions • Setting change prohibit (key protection) Input shift Temperature unit change (°C/°F) Direct/reverse operation Temperature range, Sensor switching (K/J/L, Pt100/JPt100) Switching is performed between a thermocouple and platinum resistance thermometer for universal-input models. Control period switching 8-mode alarm output Sensor error detection (excluding thermistor models) Ambient operating −10 to 55°C (with no condensation or icing); with 3-year guarantee: −10 to 50°C temperature Ambient operating humidity 25% to 85% Storage temperature −25 to 65°C (with no condensation or icing) Note: Do not use an inverter output as the power supply. (Refer to Safety Precautions for All Temperature Controllers.) 3 E5CS ■ Characteristics Setting accuracy Thermocouple (See note 1.): (±1% of indication value or ±2°C, whichever is greater) ±1 digit max. Platinum resistance thermometer (See note 2.): (±0.5% of indication value or ±1°C, whichever is greater) ±1 digit max. Indication accuracy Thermistor (See note 3.): (1% FS of indication value) ±1 digit max. (ambient temperature of 23°C) Influence of temperature R thermocouple inputs: (±2% of PV or ±10°C, whichever is greater) ±1 digit max. Other thermocouple inputs: (±2% of PV or ±4°C, whichever is greater) ±1 digit max. Influence of voltage Platinum resistance thermometer inputs: (±1% of PV or ±2°C, whichever is greater) ±1 digit max. Influence of EMS. Thermistor: (±2% FS) ±1 digit max. (at EN 61326-1) Hysteresis (for ON/OFF control) 0.2% FS (0.1% FS for universal-input (thermocouple/platinum resistance thermometer) models) Proportional band (P) 1 to 999°C (automatic adjustment using auto-tuning/self-tuning) Integral time (I) 1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning) Derivative time (D) 1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning) Alarm output range Absolute-value alarm: Same as the control range Other: 0 to input setting range full scale (°C or °F) Alarm hysteresis: 0.2°C or °F (fixed) Control period 2/20 s Sampling period 500 ms Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminals of different polarity 2 Vibration Malfunction 10 to 55 Hz, 20 m/s for 10 min each in X, Y, and Z directions resistance Destruction 10 to 55 Hz, 0.75-mm single amplitude for 2 hr each in X, Y, and Z directions 2 Shock resistance Malfunction 100 m/s min., 3 times each in six directions 2 Destruction 300 m/s min., 3 times each in six directions Life expectancy Electrical 100,000 operations min. (relay output models) Weight Approx. 110 g (Controller only) Degree of protection Front panel: Equivalent to IP50, Enclosure Category 2 (IEC 60529), Rear case: IP20; Terminals: IP00 Memory protection EEPROM (non-volatile memory) (number of writes: 1,000,000) EMC EMI Radiated: EN 55011 Group 1 Class A EMI Conducted: EN 55011 Group 1 Class A Radiated Electromagnetic Field Immunity: EN 61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) RF-interference Immunity: EN 61000-4-3: 10 V/m (80-1000 MHz, 1.4-2.0 GHz amplitude modulated) (level 3) 10 V/m (900 MHz pulse modulated) Conducted Disturbance Immunity: EN 61000-4-6: 3 V (0.15 to 80 MHz) (level 2) Noise Immunity (First Transient Burst Noise): EN 61000-4-4 Burst Immunity: 2 kV power-line (level 3), 1 kV I/O signal-line (level 3) Surge Immunity: EN 61000-4-5: Power line: Normal mode 1 kV; Common mode 2 kV Output line (relay output): Normal mode 1 kV; Common mode 2 kV Voltage Dip/Interrupting Immunity: EN 61000-4-11 0.5 cycle, 100% (rated voltage) Approved standards UL 61010-1 (listing) CSA C22.2 No.1010-1 Conformed standards EN 61326-1 (See note 4.), EN 61010-1, IEC 61010-1 Note: 1. The following exceptions apply to thermocouples. • U, L: ±2°C ±1 digit max. • R: ±3°C ±1 digit max. at 200°C or less 2. The following exception applies to platinum resistance thermometers. • Input set values 1 for E5CS-U: 1% FS ±1 digit max. 3. The following exceptions apply to thermistors. • When the unit setting is °C, temperature indication ranges exceeding the set temperature range ±10% FS may not be accurate. • When the unit setting is °F, the temperature range for the input setting numbers 4 and 9 (609 to 630°F) and temperature indication ranges exceeding the set temperature range −5% FS to +10% FS may not be accurate. 4. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2) 4 4 4 4 4 4 3 3 3 3 3 2 2 2 2 2 1 1 1 1 1 E5CS ■ Temperature Range Thermocouple Input Models Input K J/L 999 1,000 Temperature 0 900 range 800 700 (selected 600 600 500 500 using switch) 500 400 400 400 300 300 300 200 200 200 (Default setting: 2) 100 0 00 00 000 00 0 Setting number 01 234 56 78 9 The shaded value indicates the default Minimum setting unit 1°C1°C setting status. Platinum Resistance Thermometer Input Models Input JPt100/Pt100 Temperature 0 range 500 400 400 400 (selected 300 300 300 200 199.9 using switch) 200 50 50.0 80 99.9 100 0 0.0 0.0 000 00 0.0 (Default setting: 3) −100 −50 −20 Setting number 01 2 34 56 78 9 The shaded value indicates the default Minimum setting unit 1°C0.1°C1°C0.1°C1°C0.1°C setting status. Thermistor Input Models (For details on Sensors, refer to E52.) Input G 6 kΩ 6 kΩ 30 kΩ 550 Ω 4 kΩ 6 kΩ 6 kΩ 30 kΩ 550 Ω 4 kΩ Temperature 0 (0°C) (0°C) (0°C) (200°C) (200°C) (0°C) (0°C) (0°C) (200°C) (200°C) range 500 (selected 400 300 300 using switch) 300 150 200 150 200 200 50 100 50 100 100 100 150 100 150 0 050 050 −100 (Default setting: 1) −50 −50 Setting number 0 1 234 56 78 9 The shaded value indicates the default Minimum setting unit 1°C setting status. Universal-input (Thermocouple/Platinum Resistance Thermometer) Models • Using Thermocouple Sensors, Control Mode Switch 5: OFF Input K J L T UNR 1,700 1,700 1,600 1,500 1,400 1,300 1,300 1,300 Temperature 0 1,200 range 1,100 (selected 1,000 850 850 using switch) 900 800 700 600 (Default setting: 0) 500 400 400 400 300 199.9 199.9 199.9 200 100 0 0.0 0.0 0.0 0 −100 −99 −99 −99 −99 −99 −99 Setting number 01 234 56 78 9 The shaded value indicates the default Minimum setting unit 1°C0.1°C1°C0.1°C1°C0.1°C1°C setting status. • Using Platinum Resistance Thermometers, Control Mode Switch 5: ON Input Pt100 JPt100 1,000 Temperature 850 0 900 range 800 (selected 700 using switch) 600 500 500 400 400 400 300 199.9 200 199.9 200 (Default setting: 0) 200 99 99 100 0 0.0000.000 −100 −99 −99 −99 −99 Setting number 01 234 56 78 9 The shaded value indicates the default Minimum setting unit 1°C0.1°C1°C0.1°C1°C setting status. 5 9 9 9 9 9 8 8 8 8 8 7 7 7 7 7 6 6 6 6 6 5 5 5 5 5 E5CS External Connection Diagram Sensor Thermocouple (See note 3.) Platinum resistance thermometer Thermistor (See note 3.) Plug-in Without Voltage output models (See note 1.) Voltage output models (See note 1.) Voltage output models (See note 1.) models alarms 12 VDC, 12 VDC, 12 VDC, 21 mA 21 mA 21 mA Voltage Voltage Voltage output output output 4 5 4 5 4 5 Relay output models Relay output models Relay output models A 4 5 4 5 4 5 3 6 3 6 3 6 (K, J) 2 7 2 7 2 7 B B 1 8 1 8 1 8 100 to 240 VAC 100 to 240 VAC 100 to 240 VAC 24 VAC/VDC 24 VAC/VDC 24 VAC/VDC (See note 2.) (See note 2.) (See note 2.) Voltage output models Two alarm Voltage output models Two alarm Voltage output models With (See note 1.) points (See note 1.) points (See note 1.) alarms 12 VDC, 21 mA 12 VDC, 21 mA 12 VDC, 21 mA 7 7 OUT OUT OUT Alarm output 1 Alarm output 1 8 8 5 5 5 Alarm output 2 Alarm output 2 9 9 4 4 4 Relay output models Relay output models Relay output models Alarm output Alarm output Alarm output 6 6 6 5 7 5 7 5 7 4 8 4 8 4 8 A 3 9 3 9 3 9 2 10 2 10 2 10 1 11 1 11 1 11 100 to 240 VAC 100 to 240 VAC 100 to 240 VAC B 24 VAC/VDC B 24 VAC/VDC 24 VAC/VDC (See note 2.) (See note 2.) (See note 2.) Note: 1. The voltage output (12 VDC, 21 mA) is not electrically isolated from the internal circuits. When using a grounding thermocouple, do not connect output terminals 4 or 5 to ground. Otherwise, unwanted current paths will cause measurement errors. 2. Models with 100 to 240 VAC and 24 VAC/VDC are separate. Models using 24 VDC have no polarity. 3. Be sure to check the sensor type before using multi-output (thermocouple/platinum resistance thermometer) models. Nomenclature E5CS-U Plug-in Models Temperature display Output indicator Deviation indicators Mode indicators Alarm indicators Mode Key Up Key Down key 6 E5CS Dimensions Note: All units are in millimeters unless otherwise indicated. ■ Controller E5CS-U Terminal Arrangement (Bottom View) 94.45 6 4 5 5 7 (7.75) 3 6 4 8 48 × 48 6.25 72.5 3 9 2 7 2 10 1 8 1 11 Models without Models with 44.8 × 44.8 alarms alarms Panel Cutout Dimensions +0.6 45 0 L Note: The external dimensions are the same for both models with and without alarms. +0.6 +0.6 45 45 0 0 +1 60 min. L = (48 × N − 2.5) 0 Mounting side-by-side (group mounting of N Controllers) E5CS-U + Adapter for Flush Mounting (Enclosed) + Back Connecting Socket (Order Separately) (Without Alarms) Panel Y92F-30 Adapter for flush mounting Adapter for P3G-08 flush mounting Back Connecting Socket 58 Tightening screws 48 7 95 E5CS-U + Adapter for Flush Mounting (Enclosed) + Back Connecting Socket (Order Separately) (With Alarms) Panel Y92F-30 Adapter for flush mounting Adapter for P3GA-11 flush mounting Back Connecting Socket 58 Tightening screws 48 7 100 Note: Use the P2CF-08 and P3G-08 Sockets for models without alarms, and use the P2CF-11 and P3GA-11 Sockets for models with alarms. 7 9 92A-48B 2A-48B 92A-48B E5CS ■ Accessories (Order Separately) Terminal Arrangement/ 8-pin Sockets without Alarms Internal Connections (Top View) P2CF-08 Front Connecting Socket Eight, M3.5 × 7.5 sems screws 7.8 3 Mounting Hole Dimensions 4.5 6 5 4 3 Two, 4.5-dia. hole or two, M4 Two, 4.5-dia. holes 40±0.2 70 max. 35.4 Note: DIN Track mounting is also possible. 7 8 1 2 Note: The P2CF-08-E Socket with finger protection is also available. 50 max. 4 20.3 max. Terminal Arrangement 27 dia. 7 P3G-08 Back Connecting Socket (Bottom View) 9 3 4 5 6 45 2 1 8 7 17 45 M3.5 4.9 8 Note: The Y92A-48G Finger Safe Terminal Cover is also available. 11-pin Sockets with Alarms Terminal Arrangement/ Internal Connections P2CF-11 Front Connecting Socket Eleven, M3.5 × 7.5 (Top View) 7.8 3 4.5 sems screws Mounting Hole Dimensions 8 7 6 5 Two, 4 4.5-dia. Two, 4.5-dia. mounting holes holes 70 max. 35.4 40±0.2 9 3 Note: DIN Track mounting is also 10 11 1 2 possible. 50 max. 4 31.2 max. Note: The P2CF-11-E Socket with finger protection is also available. Terminal Arrangement (Bottom View) P3GA-11 Back Connecting Socket 27 dia. 47 3 5 6 7 8 4 45 25.6 3 9 2 1 11 10 45 16.3 6 4.5 6.2 8.7 Note: The Y92A-48G Finger Safe Terminal Cover is also available. Note: Do not use any other types of Sockets. Doing so will adversely affect the accuracy. Applicable Thermistors Hard Protective Cover Use Element Interchangeable Thermistors (E52-THE5A, E52- The Y92A-48B Hard Protective Cover is available for the following THE6D, and E52-THE6F) to connect to the E5CS-@GU. For details applications. on Sensors, refer to E52.  To protect the set from dust and dirt.  To prevent the panel from being accidentally touched causing displacement of set values.  To provide effective protection against water droplets. 8 E5CS Safety Precautions Refer to Safety Precautions for All Temperature Controllers. Refer to E5CS/E5CSV Operation for operating procedures. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 9 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2015.8 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2015 All Right Reserved.

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the E5CS-R1KJU-WAC100-240?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Cam Positioners With High Speed and High Precision Double Machine Productivity 3F88L160

product

Cam Positioners With High Speed and High Precision Double Machine Productivity 3F88L162

product

Controllers SURGE SUPRESSOR 61F-03B

product

Controllers SURGE SUPRESSOR 61F-04B

product

Conductive Level Controller 61F-GP-N2220VAC

product

Conductive Level Controller 61F-GP-N224VAC