OMRON AUTOMATION E5CSVQ1KJWAC100240
Specifications
Manufacturer
Omron Automation
Manufacturers Part #
E5CSVQ1KJWAC100240
Lead Time
4 Week Lead Time
Industry Aliases
E5CSV-Q1KJW-AC100-240
Sub-Categories
Miscellaneous Tools and Supplies
Factory Pack Quantity
1
Datasheet
Extracted Text
Temperature Controllers E5CSV CSM_E5CSV_DS_E_7_5 Easy Setting Using DIP Switch and Simple Functions in DIN 48 × 48 mm-size Temperature Controllers • Easy setting using DIP switch. • Models with two alarms added to Series, ideal for temperature alarm applications. • Universal-input (thermocouple/platinum resistance thermometer) models also available. • Clearly visible digital display with character height of 13.5 mm. For the most recent information on models that have been certified for • Models available with black in addition to white cases. safety standards, refer to your OMRON website. • RoHS compliant. Refer to Safety Precautions for All Temperature Controllers. Refer to E5CS/E5CSV Operation for operating procedures. Model Number Structure ■ Model Number Legend Models with Terminal Blocks E5CSV-@@@@-@ 12 3 4 5 1. Control Outputs 3. Input 4. Power Supply Voltage R: Relay KJ: Thermocouple Blank: 100 to 240 VAC Q: Voltage for driving SSR P: Platinum resistance thermometer D: 24 VAC/VDC 2. Alarm Outputs T: Thermocouple/platinum resistance 5. Case Color thermometer (universal-input) Blank: No alarm Blank: Black 1: 1 alarm W: Light gray 2: 2 alarms Note: A functional explanation is provided here for illustration, but models are not necessarily available for all possible combinations. Refer to Ordering Information when ordering. Examples • Relay control output, without alarm, thermocouple/platinum-resistance thermometer multi input, black case : E5CSV-RT • Relay control output, one alarm output, platinum resistance thermometer input, black case, light gray case : E5CSV-R1P-W 1 E5CSV Ordering Information ■ List of Models Case Color: Light Gray, Thermocouple or Platinum Resistance Thermometer, Power Supply Voltage: 100 to 240 VAC Size Type Control Alarms Outputs Model with Model with platinum modes thermocouple resistance thermometer E5CSV Terminal block ON/OFF or 1 Relay E5CSV-R1KJ-W E5CSV-R1P-W PID 48 × 48mm Voltage (for driving SSR) E5CSV-Q1KJ-W E5CSV-Q1P-W Case Color: Light Gray, Thermocouple, Power Supply Voltage: 24 VAC/VDC Size Type Control Alarms Outputs Model with modes thermocouple E5CSV Terminal block ON/OFF or 1 Relay E5CSV-R1KJD-W PID 48 × 48mm Case Color: Light Gray, Universal-input, Power Supply Voltage: 100 to 240 VAC Size Type Control Alarms Outputs Model with universal- modes input (thermocouple or platinum resistance thermometer) E5CSV Terminal block ON/OFF or 0Relay E5CSV-RT PID 48 × 48mm Voltage (for driving SSR) E5CSV-QT 1 Relay E5CSV-R1T Voltage (for driving SSR) E5CSV-Q1T 2 (See note.) Relay E5CSV-R2T Voltage (for driving SSR) E5CSV-Q2T Note: There is no alarm output 2 mode switch. The default setting for alarm output 2 is for the upper limit alarm mode. To change the setting, change the alarm type for alarm output 2 in initial setting level 5. For details, refer to the “E5CSV/E5CS-U Digital Temperature Controller User’s Manual” (Cat. No. H140-E1-01). Case Color: Black, Universal-input, Power Supply Voltage: 24 VAC/VDC Size Type Control Alarms Outputs Model with universal- modes input (thermocouple or platinum resistance thermometer) E5CSV Terminal block ON/OFF or 0Relay E5CSV-RTD PID 48 × 48mm Voltage (for driving SSR) E5CSV-QTD 1 Relay E5CSV-R1TD Voltage (for driving SSR) E5CSV-Q1TD 2 (See note.) Relay E5CSV-R2TD Voltage (for driving SSR) E5CSV-Q2TD Note: There is no alarm output 2 mode switch. The default setting for alarm output 2 is for the upper limit alarm mode. To change the setting, change the alarm type for alarm output 2 in initial setting level 5. For details, refer to the “E5CSV/E5CS-U Digital Temperature Controller User’s Manual” (Cat. No. H140-E1-01). ■ Accessories (Order Separately) Protective Cover DIN Track Mounting Adapter Type Model Model Hard Protective Cover Y92A-48B Y92F-52 Terminal Cover Rubber Packing Model Model E53-COV10 Y92S-29 Terminal Cover Note: The Rubber Packing is provided with the Digital Controller. (For Controllers after the design change scheduled for October 2010) Model E53-COV17 Note: The E53-COV10 Terminal Cover cannot be mounted to Controllers that are manufactured after the design change scheduled for October 2010 2 E5CSV Specifications ■ Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage Power consumption 100 to 240 VAC: 5 VA 24 VAC: 3 VA, 24 VDC: 2 W Sensor input Thermocouple input type: K, J, L Platinum resistance thermometer input type: Pt100, JPt100 Universal-input (thermocouple/platinum resistance thermometer) type: K, J, L, T, U, N, R, Pt100, JPt100 Control Relay output SPST-NO, 250 VAC, 3A (resistive load) output Voltage output (for driving the SSR) 12 VDC, 21 mA (with short-circuit protection circuit) Control method ON/OFF or 2-PID (with auto-tuning) Alarm output SPST-NO, 250 VAC, 1A (resistive load) Setting method Digital setting using front panel keys Indication method 7-segment digital display (character height: 13.5 mm) and deviation indicators Other functions • Setting change prohibit (key protection) • Input shift • Temperature unit change (°C/°F) • Direct/reverse operation • Temperature range, Sensor switching (K/J/L, Pt100/JPt100) • Switching is performed between a thermocouple and platinum resistance thermometer for universal-input models. • Control period switching • 8-mode alarm output • Sensor error detection Ambient operating temperature −10 to 55°C (with no condensation or icing); with 3-year guarantee: −10 to 50°C Ambient operating humidity 25% to 85% Storage temperature −25 to 65°C (with no condensation or icing) Note: 1. Do not use an inverter output as the power supply. (Refer to Safety Precautions for All Temperature Controllers.) 2. Models for 24 VAC/DC can also be manufactured. ■ Characteristics Setting accuracy Thermocouple (See note 1.): (±0.5% of indication value or ±1°C, whichever is greater) ±1 digit max. Platinum resistance thermometer (See note 2.): (±0.5% of indication value or ±1°C, whichever is greater) ±1 digit max. Indication accuracy (ambient temperature of 23°C) Influence of temperature R thermocouple inputs: (±1% of PV or ±10°C, whichever is greater) ±1 digit max. Other thermocouple inputs: (±1% of PV or ±4°C, whichever is greater) ±1 digit max. Influence of voltage whichever is greater) ±1 digit max. Platinum resistance thermometer inputs: (±1% of PV or ±2°C, Influence of EMS. (at EN61326-1) Hysteresis (for ON/OFF control) 0.2% FS (0.1% FS for universal-input (thermocouple/platinum resistance thermometer) models) Proportional band (P) 1 to 999°C (automatic adjustment using auto-tuning/self-tuning) Integral time (I) 1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning Derivative time (D) 1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning) Alarm output range Absolute-value alarm: Same as the control range Other: 0 to input setting range full scale (°C or °F) Alarm hysteresis: 0.2°C or °F (fixed) Control period 2/20 s Sampling period 500 ms Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminals of different polarity 2 Vibration Malfunction 10 to 55 Hz, 20 m/s for 10 min each in X, Y, and Z directions resistance Destruction 10 to 55 Hz, 0.75-mm single amplitude for 2 hr each in X, Y, and Z directions 2 Shock resistance Malfunction 100 m/s min., 3 times each in 6 directions 2 Destruction 300 m/s min., 3 times each in 6 directions Life expectancy Electrical 100,000 operations min. (relay output models) Weight Approx. 120 g (Controller only) Degree of protection Front panel: Equivalent to IP66; Rear case: IP20; Terminals: IP00 Memory protection EEPROM (non-volatile memory) (number of writes: 1,000,000) EMC EMI Radiated: EN 55011 Group 1 Class A EMI Conducted: EN 55011 Group 1 Class A ESD Immunity: EN 61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Radiated Electromagnetic Field Immunity: EN 61000-4-3: 10 V/m (80-1000 MHz, 1.4-2.0 GHz amplitude modulated) (level 3) 10 V/m (900 MHz pulse modulated) Conducted Disturbance Immunity: EN 61000-4-6: 3 V (0.15 to 80 MHz) (level 2) Noise Immunity (First Transient Burst Noise): EN 61000-4-4 Burst Immunity: 2 kV power-line (level 3), 1 kV I/O signal-line (level 3) Surge Immunity: EN 61000-4-5: Power line: Normal mode 1 kV; Common mode 2 kV Output line (relay output): Normal mode 1 kV; Common mode 2 kV Voltage Dip/Interrupting Immunity: EN 61000-4-11 0.5 cycle, 100% (rated voltage) Approved standards UL 61010-1 (listing) CSA C22.2 No.1010-1 Conformed standards EN61326-1 (See note 3.), EN61010-1, IEC61010-1 VDE 0106 Part 100 (finger protection), when the terminal cover is mounted. Note: 1. The following exceptions apply to thermocouples. • U, L: ±2°C ±1 digit max. • R: ±3°C ±1 digit max. at 200°C or less 2. The following exceptions apply to platinum resistance thermometers. Input set values 0, 1, 2, 3 for E5CSV: 0.5% FS ±1 digit max. 3. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2) 3 5 5 5 5 4 4 4 4 3 3 3 3 2 2 2 2 1 1 1 1 E5CSV ■ Temperature Range Thermocouple Input Models Input K J/L 999 1,000 Temperature 900 range 800 700 (selected 600 600 500 500 using switch) 500 400 400 400 300 300 300 200 200 200 (Default setting: 2) 100 0 0 000 00 000 0 Setting number 01 23 45 678 9 The shaded value indicates the default Minimum setting unit 1°C1°C setting status. Platinum Resistance Thermometer Input Models Input JPt100/Pt100 Temperature range 500 400 400 400 (selected 300 300 300 200 199.9 using switch) 200 50 50.0 80 99.9 100 0 0.0 0.0 00 000 0.0 (Default setting: 3) −100 −50 −20 Setting number 01 2 34 56 7 89 The shaded value indicates the default Minimum setting unit 1°C0.1°C1°C0.1°C1°C0.1°C setting status. Universal-input (Thermocouple/Platinum Resistance Thermometer) Models • Using Thermocouple Sensors, Control Mode Switch 5: OFF Input K J L T U N R 1,700 1,700 1,600 1,500 1,400 1,300 1,300 1,300 Temperature 1,200 range 1,100 (selected 1,000 850 850 using switch) 900 800 700 600 (Default setting: 0) 500 400 400 400 300 199.9 199.9 199.9 200 100 0 0.0 0.0 0.0 0 −100 −99 −99 −99 −99 −99 −99 Setting number 01 23 45 678 9 The shaded value indicates the default Minimum setting unit 1°C0.1°C1°C0.1°C1°C0.1°C1°C setting status. • Using Platinum Resistance Thermometers, Control Mode Switch 5: ON Input Pt100 JPt100 1,000 Temperature 850 900 range 800 (selected 700 using switch) 600 500 500 400 400 400 300 199.9 200 199.9 200 200 (Default setting: 0) 99 99 100 0 0.0000.000 −100 −99 −99 −99 −99 Setting number 01 23 45 678 9 The shaded value indicates the default Minimum setting unit 1°C0.1°C1°C0.1°C1°C setting status. 4 0 0 0 0 9 9 9 9 8 8 8 8 7 7 7 7 6 6 6 6 E5CSV External Connection Diagram Voltage output models Relay output Alarm output (See note 1.) models Voltage output Relay output 1 1 1 6 12 VDC, 21 mA Alarm output 2 (See note 3 2 2 2 7 Alarm output 1 (See note 3 A 3 3 8 B 4 4 9 100 to 240 VAC, 50/60 Hz (24 VAC/VDC) B (See note 2.) 5 5 10 Platinum resistance Thermocouple thermometer input input Thermocouple/ platinum resistance thermometer universal-input Note: 1. The voltage output (12 VDC, 21 mA) is not electrically isolated from the internal circuits. When using a grounding thermocouple, do not connect output terminals 1 or 2 to ground. Otherwise, unwanted current paths will cause measurement errors. 2. Models with 100 to 240 VAC and 24 VAC/VDC are separate. Models using 24 VDC have no polarity. 3. The number of alarm outputs depends on the model. Nomenclature E5CSV Models with Terminal Blocks Output indicator Deviation indicators Temperature display Mode indicators Alarm indicators Mode Key Up Key Lock Release Key Down Key 5 E5CSV Dimensions Note: All units are in millimeters unless otherwise indicated. ■ Controller E5CSV Panel Cutout Dimensions 84 +0.6 45 0 48×48 6 78 L +0.6 +0.6 45 0 45 0 44.8×44.8 +1 60 min. L = (48 × N−2.5) 0 Mounting side-by-side (group mounting of N Controllers) Note: Terminals cannot be removed. E5CSV + Adapter for Flush Mounting Panel Y92F-30 Adapter for flush mounting (Provided) Adapter for flush mounting 58 Tightening screws 48 7.5 76.5 Note: 1. The recommended panel thickness is 1 to 4 mm. 2. Group mounting is possible in one direction only. DIN Track Mounting Adapter Y92F-52 Note: This Adapter cannot be used together with the Terminal Cover. Remove the Terminal Cover to use the Adapter. 61 3.5 50 38 Mounted to E5CSV 48 100.5 6 9 92A-4 92A-4 2A-4888B B B °C E5CSV ■ Accessories (Order Separately) Hard Protective Cover The Y92A-48B Protective Cover (hard type) is available for the following applications. To protect the set from dust and dirt. To prevent the panel from being accidentally touched causing displacement of set values. To provide effective protection against water droplets. Terminal Cover Rubber Packing E53-COV10 Y92S-29 (for DIN48 × 48) 48 Order the Rubber Packing separately if it becomes lost or damaged. The Rubber Packing can be used to 48.8 achieve an IP66 degree of protection for models with terminal blocks. (Deterioration, shrinking, or hardening of the rubber packing may occur depending on the operating 22 environment. Therefore, periodic replacement is recommended to ensure the level of waterproofing specified in NEMA4. The time for periodic replacement depends on the operating environment. Be sure to 9.1 confirm this point at your site. Consider one year a E53-COV17 rough standard. OMRON shall not be liable for the level 48 of water resistance if the customer does not perform periodic replacement.) The Rubber Packing does not need to be attached if a 48.8 waterproof structure is not required. 22 (For Controllers after the design change scheduled 9.1 for October 2010) Safety Precautions Refer to Safety Precautions for All Temperature Controllers. Refer to E5CS/E5CSV Operation for operating procedures. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 7 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2015.8 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2015 All Right Reserved.
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the E5CSVQ1KJWAC100240?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods