OMRON AUTOMATION K3HB-PNB100-240VAC
Specifications
Manufacturer
Omron Automation
Manufacturers Part #
K3HB-PNB100-240VAC
Lead Time
4 Week Lead Time
Industry Aliases
K3HB-PNB100-240 VAC
Sub-Categories
Miscellaneous Tools and Supplies
Factory Pack Quantity
1
Datasheet
Extracted Text
Timer Interval Indicator
K3HB-P
CSM_K3HB-P_DS_E_15_2
Digital Time Interval Meter for Measuring
Passing Speed, Time, or Cycle between Two
Points.
• Visual confirmation of judgement results through display colors that
switch between red and green. *1
• Measures Wide Range of Pulse Interval Times
Measures, calculates, and displays pulse intervals between two points. Wide
range for pulse interval measurements, from 10 ms to 3,200 s, max.
• Six Measurement Operations, Including Passing Speed, Time, and
Cycle Measurement between Two Points
One Digital Time Interval Meter has six measurement functions, to support a
variety of pulse interval measurement applications. Select the best function
for your application from the following: Passing speed, cycle, time difference,
time band, measuring length, and interval.
• DeviceNet models added to the series. *2
*1 Visual confirmation of judgement results is not supported on models that do not have an
For the most recent information on models that have been certified for
output or models that do not support DeviceNet.
safety standards, refer to your OMRON website.
You can change the display color by setting it, but you cannot switch it based on the judgement results.
*2 DeviceNet models have a depth of 97 mm.
Refer to Safety Precautions for All Digital Panel
Meters.
Model Number Structure
■ Model Number Legend
Base Units and Optional Boards can be ordered individually or as sets.
Base Units Base Units with Optional Boards
K3HB-P @ K3HB-P@-@@@
15 1 234 5
2. Sensor Power Supply/Output Type Code
1. Input Sensor Code
NB: NPN input/voltage pulse input None: None
PB: PNP input CPA: Relay output (PASS: SPDT) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 1.)
5. Supply Voltage
L1A: Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power supply
100-240 VAC: 100 to 240 VAC
(12 VDC±10%, 80 mA) (See note 2.)
24 VAC/VDC: 24 VAC/VDC
L2A: Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
Optional Board
A: Sensor power supply (12 VDC ±10%, 80 mA)
FLK1A: Communications (RS-232C) + Sensor power supply
Sensor Power Supply/Output Boards
(12 VDC±10%, 80 mA) (See note 2.)
FLK3A: Communications (RS-485) + Sensor power supply
K33-@
(12 VDC±10%, 80 mA) (See note 2.)
2
Note: 1. CPA can be combined with relay outputs only.
2. Only one of the following can be used by each Digital Indicator: RS-232C/RS-
Relay/Transistor Output Boards
485 communications, a linear output, or DeviceNet communications.
3. Relay/Transistor Output Type Code
K34-@
None: None
3
C1: Relay contact (H/L: SPDT each)
C2: Relay contact (HH/H/LL/L: SPST-NO each)
Event Input Boards
T1: Transistor (NPN open collector: HH/H/PASS/L/LL)
T2: Transistor (PNP open collector: HH/H/PASS/L/LL)
BCD∗: BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL)
K35-@
DRT: DeviceNet (See note 2.)
4
∗ A Special BCD Output Cable (sold separately) is required.
4. Event Input Type Code
None: None
1: 5 inputs (HOLD/RESET), NPN open collector
2: 8 inputs (HOLD/RESET/BANK1/BANK2/BANK4), NPN open collector
3: 5 inputs (HOLD/RESET), PNP open collector
4: 8 inputs (HOLD/RESET/BANK1/BANK2/BANK4), PNP open collector
Note: The following combinations are not possible.
• Communications (FLK@A) + DeviceNet (DRT)
• Communications (FLK@A) + BCD output (BCD)
• Linear current/voltage (L@A) + DeviceNet (DRT)
1
K3HB-P
Accessories (Sold Separately)
K32-DICN: Special Cable (for event inputs with 8-pin connector)
K32-BCD: Special BCD Output Cable
Watertight Cover Rubber Packing
Model
Model
Y92A-49N
K32-P1
Note: Rubber packing is provided with the Controller.
Specifications
■ Ratings
Supply voltage 100 to 240 VAC, 24 VAC/VDC, DeviceNet power supply: 24 VDC
Allowable power supply voltage 85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC
range
Power consumption 100 to 240 VAC: 18 VA max. (max. load)
(See note 1.) 24 VAC/DC: 11 VA/7 W max. (max. load)
Current consumption DeviceNet power supply: 50 mA max. (24 VDC)
Input No-voltage contact, voltage pulse, open collector
External power supply 12 VDC 10%, 80 mA (for models with external power supplies only)
Event inputs Hold input NPN open collector or no-voltage contact signal
(See note 2.)
ON residual voltage: 2 V max.
Reset input
ON current at 0 Ω: 4 mA max.
Bank input
Max. applied voltage: 30 VDC max.
OFF leakage current: 0.1 mA max.
Output ratings Relay output 250 VAC, 30 VDC, 5 A (resistive load)
(depends on
Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations
the model)
Transistor output Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 μA max.
Linear output Linear output 0 to 20 mA DC, 4 to 20 mA DC:
Load: 500 Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS
Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC:
Load: 5 kΩ max, Resolution: Approx. 10,000, Output error: ±0.5% FS
(1 V or less: ±0.15 V; no output for 0 V or less)
Display method Negative LCD (backlit LED) display
7-segment digital display (Character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green))
Main functions Scaling function, measurement operation selection, output hysteresis, output OFF delay, output test, teaching, dis-
play value selection, display color selection, key protection, bank selection, display refresh period, maximum/mini-
mum hold, reset
Ambient operating temperature
−10 to 55°C (with no icing or condensation)
Ambient operating humidity
25% to 85%
Storage temperature
−25 to 65°C (with no icing or condensation)
Altitude 2,000 m max.
Watertight packing, 2 fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include a De-
Accessories
viceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3.)
Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular
attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is
recommended.
2. PNP input types are also available.
3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for
Thin Cables.
2
K3HB-P
■ Characteristics
Display range −19,999 to 99,999
Measurement accuracy ±0.08% rgd ±1 digit (for voltage pulse/open collector sensors)
(at 23±5°C)
Measurement range Functions F1, F3, and F4:(Interval between input pulses) 10 ms to 3,200 s
Function F2: (Interval between input pulses) 20 ms to 3,200 s
Functions F5, F6: (Number of input pulses) 0 to 4 gigacounts
Input signals • Contact input (dry contact input) (30 Hz max. with ON/OFF pulse width of 15 ms min.)
• No contact
Mode Input frequency ON/OFF ON voltage OFF voltage Input
voltage pulse
range pulse width impedance
F1 to F4 0 to 50 kHz 9 μs min. 4.5 to 30 V −30 to 2 V 10 kΩ
F5, F6 0 to 30 kHz 16 μs min.
• Open collector
Mode Input frequency ON/OFF Note: The Digital Time Interval Meter
range pulse width will malfunction if a pulse greater
than the input frequency range is
F1 to F4 0 to 50 kHz 9 μs min.
input. SYSERR may appear on
F5, F6 0 to 30 kHz 16 μs min. the display.
Connectable sensors ON residual voltage: 3 V max.
OFF leakage current: 1.5 mA max.
Load current: Must have a switching capacity of 20 mA or higher.
Must be able to properly switch load currents of 5 mA or less.
Comparative output response 2 ms max. (time until the comparative output is made when there is a forced sudden change in the input signal
time (transistor output) from 15% to 95% or 95% to 15%)
Linear output response time 10 ms max. (time until the final analog output value is reached when there is a forced sudden change in the
input signal from 15% to 95% or 95% to 15%)
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 2,300 VAC for 1 min between external terminals and case
Noise immunity 100 to 240 VAC models:
±1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 μs/100 ns)
24 VAC/VDC models:
±1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 μs/100 ns)
2
Vibration resistance
Frequency: 10 to 55 Hz; Acceleration: 50 m/s , 10 sweeps of 5 min each in X, Y, and Z directions
2 2
Shock resistance
150 m/s (100 m/s for relay outputs) 3 times each in 3 axes, 6 directions
Weight Approx. 300 g (Base Unit only)
Degree of Front panel Conforms to NEMA 4X for indoor use (equivalent to IP66)
protection
Rear case IP20
Terminals IP00 + finger protection (VDE0106/100)
Memory protection EEPROM (non-volatile memory)
Number of rewrites: 100,000
Applicable standards UL61010-1, CSA C22.2 No. 61010-1-04
EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II
EN61326-1
EMC EMI: EN61326-1 Industrial electromagnetic environment
Electromagnetic radiation interference
CISPR 11 Group 1, Class A
Terminal interference voltage
CISPR 11 Group 1, Class A
EMS: EN61326-1 Industrial electromagnetic environment
Electrostatic Discharge Immunity
EN61000-4-2: 4 kV (contact), 8 kV (in air)
Radiated Electromagnetic Field Immunity
EN61000-4-3: 10 V/m sine wave amplitude modulation (80 MHz to 1 GHz, 1.4GHz to 2 GHz)
Electrical Fast Transient/Burst Noise Immunity
EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line)
Surge Immunity
EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line)
Conducted Disturbance Immunity
EN61000-4-6: 3 V (0.15 to 80 MHz)
Power Frequency Magnetic Immunity
EN61000-4-8: 30 A/m (50 Hz) continuous time
Voltage Dips and Interruptions Immunity
EN61000-4-11: 0.5 cycle, 0°/180°, 100% (rated voltage)
3
K3HB-P
Operation
■ Functions (Operating Modes)
F1 to F6
These functions use the internal system clock to measure the time between pulses or the pulse ON time and then display time measurements or
a variety of other calculations.
Example: F1 Passing Speed
The time (T) between input A pulse and input B pulse
is measured by the internal system clock. If, for
Function name Function No.
example, the system clock measures 100,000 counts
during time T, then
Passing speed f1
Input A
T = 1 system clock count (0.5 μs) × 100,000
Cycle f2
T = 0.05 s
Time difference f3
Input B
F1 (the passing speed) is calculated internally
Time band f4
1
T
using the formula × 60 (m/min), and the
T
Measuring length f5
1
Internal
display, in this example, would be × 60=
Interval f6
system clock
0.05 s
1
1
1200 (m/min).
Function Operation Operation image (application)
F1 The reciprocal of the time (T) from input A ON to input Measuring workpiece passing speed between A and B
Passing B ON is multiplied by 60 and displayed.
speed Display value D = 1/T × 60 × α, α: Prescaling value
A
B
Input A
Input B
T2 TR T3 T4
T1 TR TR
HOLD input
1 1 1
Display
× 60 × 60 × 60
T1 T2 T4
RRecovery time (T ) of 20 ms is required before
starting the next measurement.
⎛ Display unit: ⎞
⎜
⎟
mm/s, m/s
⎜ ⎟
m/min, km/h, etc.
⎝ ⎠
F2 Measures and displays input A cycle (T). Measuring feed cycles for parts
Cycle Display value D = T × α, α: Prescaling value
Input A
T1 T2 T3 T4 T5
HOLD input
Display
T1 T2 T5
Measurement range: 20 ms to 3,200 s
⎛ Display unit: ⎞
⎜ ⎟
ms, s, min.,
⎜ ⎟
min.s.1/10 s
⎝
⎠
Measuring workpiece passing time Measuring the length of a
F3 Displays the time (T) from input A ON to input B ON.
between A and B workpiece step by changing
Time dif- Display value D = T × α, α: Prescaling value
prescale values.
ference
Input A
Input B
T2 T3 T4
A
T1 TR TR TR
B
HOLD input
Display
T1 T3 T4
Measurement range: 10 ms to 3,200 s
RRecovery time (T ) of 20 ms is required before
starting the next measurement.
⎛ Display unit: ⎞
⎜
⎟
ms, s, min.,
⎜ ⎟
min.s.1/10 s
⎝ ⎠
4
K3HB-P
Function Operation Operation image (application)
F4 Displays input A ON time (T).
Monitoring the ON time of a printing Managing the valve release
Time band Display value D = T × α,
press time
α: Prescaling value
Communications
Input A
output
T1 T2 TR T3
TR
HOLD input
Display
T1 T3
Measurement range: 10 ms to 3,200 s
RRecovery time (T ) of 20 ms is required before
starting the next measurement.
⎛ Display unit: ⎞
⎜ ⎟
ms, s, min.,
⎜ ⎟
min.s.1/10 s
⎝ ⎠
F5 Displays the number of input A pulses while input B is Measuring workpiece length
Measuring ON.
length Display value D = C × α,
C: Pulse value
BCD
To Programmable Controller
α: Prescaling value
12345 6 12345
Input A
Input B
HOLD input
Display
65
RRecovery time (T ) of 20 ms is required before
starting the next measurement.
⎛
Display unit: ⎞
⎜
⎟
mm, cm, m, etc.
⎝
⎠
F6 Displays the number of input A pulses from when input Measuring slit intervals
Interval B turns ON until input B turns ON again. Measurement
is made every other time input B turns ON.
H
Display value D = C × α,
PASS
C: Pulse value
α: Prescaling value
L
OK judgment
1234 1 2 3 4 1 2 1
Input A
Input B
TR TR
HOLD input
12 3 1 2 1 2
INA
TR TR
Display
3 4
INB
RRecovery time (T ) of 20 ms is required before
3 2
Display
starting the next measurement.
⎛ Display unit: ⎞
⎜ ⎟
mm, cm, m, etc.
⎝ ⎠
■ What Is Prescaling?
To make calculations using the input pulse to display the passing speed between two points, the distance between the two points and the display
unit must be set and the internally measured time multiplied by a certain coefficient. This coefficient is called the prescale value. (For information
on settings details, refer to the User's Manual.)
Time Unit Settings Input Type Setting
Setting Meaning
NO: Voltage pulse high NC: Voltage pulse low
off Seconds display when prescaling = 1.0000 No-contact or 00 01
voltage pulse
min Minutes display when prescaling = 1.0000
input
h.mm.ss h.mm.ss display
Contact 10 11
mm.ss.d mm.ss.d display (d = tenths of a second)
Note: Set to 10 or 11 when there is a large variation in the display.
The largest measurement range is 30 Hz.
5
K3HB-P
Common Specifications
■ Event Input Ratings
K3HB-P/-C HOLD, RESET, BANK1, BANK2, BANK4
Contact ON: 1 kΩ max., OFF: 100 kΩ min.
No-contact ON residual voltage: 2 V max.
OFF leakage current: 0.1 mA max.
Load current: 4 mA max.
Maximum applied voltage: 30 VDC max.
■ Output Ratings
Contact Output Transistor Outputs
Resistive loads Inductive loads
Maximum load voltage 24 VDC
(250 VAC, cosφ=1; (250 VAC, closed
Maximum load current 50 mA
30 VDC, L/R=0 ms) circuit, cosφ=0.4;
Item 30 VDC, L/R=7 ms)
Leakage current 100 μA max.
Rated load 5 A at 250 VAC 1 A at 250 VAC
5 A at 30 VDC 1 A at 30 VDC
Mechanical life 5,000,000 operations
expectancy
Electrical life 100,000 operations
expectancy
Linear Output
Item Outputs 0 to 20 mA 4 to 20 mA 0 to 5 V 1 to 5 V 0 to 10 V
Allowable load impedance 500 Ω max. 5 kΩ min.
Resolution Approx. 10,000
Output error ±0.5% FS ±0.5% FS
(±0.15 V for 1 V or less and no output for 0 V)
Serial Communications Output BCD Output I/O Ratings
Item Type RS-232C, RS-485
(Input Signal Logic: Negative)
Communications method Half duplex
I/O signal name Item Rating
Synchronization method Start-stop synchronization (asynchronous)
Inputs REQUEST Input signal No-voltage
Baud rate 9600/19200/38400 bps contact input
HOLD
MAX
Transmission code ASCII
Input current for no-voltage input 10 mA
MIN
Data length 7 bits or 8 bits Signal level ON voltage 1.5 V max.
RESET
Stop bit length 2 bits or 1 bit
OFF voltage 3 V min.
Error detection Vertical parity and FCS Outputs DATA Maximum load voltage 24 VDC
POLARITY
Parity check Odd, even
OVER
Maximum load current 10 mA
DATA VALID
RUN
Leakage current 100 μA max.
HH Maximum load voltage 24 VDC
H
PASS
Maximum load current 50 mA
L
LL
Leakage current 100 μA max.
Refer to the K3HB Communications User's Manual (Cat. No. N129)
for details on serial and DeviceNet communications.
6
K3HB-P
DeviceNet Communications
Communications protocol Conforms to DeviceNet
Supported Remote I/O Master-Slave connection (polling, bit-strobe, COS, cyclic)
communications communications
Conforms to DeviceNet communications standards.
I/O allocations Allocate any I/O data using the Configurator.
Allocate any data, such as DeviceNet-specific parameters and variable area for Digital Indicators.
Input area: 2 blocks, 60 words max.
Output area: 1 block, 29 words max.
(The first word in the area is always allocated for the Output Execution Enabled Flags.)
Message Explicit message communications
communications
CompoWay/F communications commands can be executed
(using explicit message communications)
Connection methods Combination of multi-drop and T-branch connections (for trunk and drop lines)
Baud rate DeviceNet: 500, 250, or 125 Kbps (automatic follow-up)
Communications media Special 5-wire cable (2 signal lines, 2 power supply lines, 1 shield line)
Communications distance
Baud rate Network length Drop line length Total drop line length
(max.) (max.) (max.)
500 Kbps 100 m max. 6 m max. 39 m max.
(100 m max.)
250 Kbps 100 m max. 6 m max. 78 m max.
(250 m max.)
125 Kbps 100 m max. 6 m max. 156 m max.
(500 m max.)
The values in parentheses are for Thick Cable.
Communications power supply 24-VDC DeviceNet power supply
Allowable voltage fluctuation range 11 to 25-VDC DeviceNet power supply
Current consumption 50 mA max. (24 VDC)
Maximum number of nodes 64 (DeviceNet Configurator is counted as one node when connected.)
Maximum number of slaves 63
Error control checks CRC errors
DeviceNet power supply Supplied from DeviceNet communications connector
7
K3HB-P
Connections
■ External Connection Diagrams
Terminal Arrangements
Note: Refer to Internal Block Diagram on page 10 for information on isolation.
ABC D E
A Operating Power Supply
1
2
100 to 240 VAC
3
24 VAC/VDC
4
5
A1
6
A2
*Check the required power supply type.
B Sensor Power Supply/Output
Sensor power supply + PASS output C Relays, Transistors, BCD and DeviceNet
B1
Relay Outputs Relay Outputs Transistor Outputs DeviceNet Connector (Included)
PASS B2
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the K3HB-PNB100-240VAC?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers





What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods