Limit Touch Switch
NL
CSM_NL_DS_E_2_2
Object Actuates Switch and Turns
Built-in Monitor Indicator ON
• Instantaneous operation upon contact with extremely
limited hysteresis for high-precision position detection.
• Detects minute displacement or lightweight objects with
minimal operating force.
• Built-in LED indicator ensures easy operation monitoring.
• DC models provide versatile functions in combination
with the S3D2 Sensor Controller.
Be sure to read Safety Precautions on page 6 to 7 and
Safety Precautions for All Limit Switches.
Application Examples
· Detection of press completion position. · Drill positioning. · Detection of workpiece edges.
· Detection of mistakes in workpiece · Material positioning.
setting or removal.
· Detection of minute workpieces.
Press
Workpiece
NL NL NL
Paper (cloth)
Grounding Grounding
rod rod
NL NL
(Ground)
· Detection of paper or cloth edge
· Displacement detection and control. · Thickness control of rolling plates.
(using indirect grounding).
Pressure
NL
Paper (cloth)
NL
Roller
Ground side
Bellows
· Detection of paper or cloth seam
(using indirect grounding).
NL
Controller
Motor
NL
Controller
Unit
Unit
NL
Grounding rod
Paper (cloth)
1
NL
Ordering Information
Built-in Antenna Model
Model Built-in antenna model
· Provides sufficient OT (overtravel). · Ensures high-precision positioning control.
Features
· Antenna tip withstands bending. · OT of 5-mm max. (overtravel)
Coil spring Plunger
Antenna
Series Power supply voltage Model Model
NL1 12 VDC NL1-C NL1-P
NL2 24 VDC NL2-C NL2-P
100 VAC NL3-C 100V NL3-P 100V
NL3
200 VAC NL3-C 200V NL3-P 200V
Antenna only NL1-C ANTENNA ASSY (Same for NL1, NL2, and NL3) ---
Note: Each model is provided with a standard 1-m cable.
Separate Antenna Model
Model Separate antenna model
Features · Antenna with 3-m extension cable is available for narrow spaces where conventional limit switches cannot be used.
No antenna Plunger Coil spring with antenna
with antenna
Antenna
Series Power supply voltage Model Model Model
NL1 12 VDC NL1-S NL1-SP NL1-SC
NL2 24 VDC NL2-S NL2-SP NL2-SC
Antenna only --- --- NL1-SC ANTENNA (Same for NL1 and NL2)
Note: Each model is provided with a standard 1-m cable.
Specifications
Item Model NL1 NL2 NL3
Degree of protection IP60
Supply voltage 12 VDC 24 VDC 100 VAC or 200 VAC
Rated frequency --- 50/60 Hz
Grounded object: Contact resistance of 3 kΩ max.
Sensitivity
Non-grounded object: Antenna-to-ground capacitance of 100 pF min.
Current consumption 8 mA 15 mA ---
Leakage current --- Circuit: 2 mA; Antenna: 1 mA *1
Response time 5 ms max. 20 ms max.
Voltage output model: 30 mA at Current output model: Thyristor output model:
Output signal 12 VDC with output 24 VDC (directly switching 100 or 200 VAC (directly switching resistive
impedance of 4.7 kΩ resistive load of 170 mA max.) load of 30 to 300 mA) *2
Insulation resistance 0 V (blue lead wire) is connected to casing 100 MΩ min. at 500 VDC *3
Dielectric strength 0 V (blue lead wire) is connected to casing 1,500 VAC at 50/60 Hz for 1 min *3
Pollution degree
3 (IEC947-5-1)
(operating environment)
Protection against
Class II
electric shock
Proof tracking index (PTI) 175
Switch category D (IEC335)
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude
2
Shock resistance 200 m/s max.
Ambient temperature −10°C to +60°C (with no icing)
Ambient humidity 35% to 95%RH
Weight Approx. 370 g (NL@-C, -P) Approx. 550 g (NL@-S) Approx. 680 g (NL@-SP, -SC)
*1. The NL3 has a capacitor and resistor for the protection of the built-in SCR. Therefore, the NL3 has leakage current.
*2. The NL3 requires a current of 30 mA for circuit protection.
Red (Brown)
If the load current is less than 30 mA, connect the bleeder resistance R in i
Power supply
Load
parallel with the load as shown below so that the total current of the load circuit will be 30 to 300 mA. White
100 VAC
(Black)
(200 VAC)
Obtain R from the following formula.
R
NL3
Black (Blue)
V
R= (kΩ)
−
30 i
Make sure that the permissible power of the resistor is sufficient.
*3. Between current-carrying and non-current-carrying metal parts
2
NL
Structure and Nomenclature
Nomenclature
Coil spring antenna
Antenna assy
O-ring
Head
LED operation
indicator
Rubber packing
Cover
(not removable)
Mounting hole
(with mounting pitch
conforming to DIN standards)
SC connector
(not removable)
Cable
Principle of Operation
The Limit Touch Switch Constants of the Switching circuit Applicable to a variety of
constantly emits a high oscillation circuit will operate and purposes in combination
frequency. If an object will change and send out output with a dedicated sensor
comes in touch with the oscillation will stop. signals. power supply.
touch antenna, ..
Feedback
circuit
Antenna
Oscillation Wave detec- S3D Sensor 100 VAC
NOT circuit
circuit tion circuit Power Supply (200 VAC)
Classification by Series and Features
NL1 NL2 NL3
Power supply
12 VDC
Sensor Load 100 VAC
Load (24 VDC, 170 mA)
Load with 30 to 300 mA
power supply (200 VAC)
Power supply NL2 L/R=0
NL3 (cos φ = 1) at 100/200 VAC
NL1 S3D2:
The S3D2 Controller is available 100 to 240 VAC
and has a variety of functions, Connects to 100/200 VAC
The NL2 with 24 VDC can
thus ensuring ease of use.
power supply and directly
directly switch the load.
switches AC loads.
Applicable model Sensor Controller Function Power supply voltage
S3D2-AK Basic operation
NL1 S3D2-BK Memory and timer operation 100 to 240 VAC
S3D2-CK Timer operation
S3D2-AKD Basic operation
NL2 24 VDC
S3D2-CKD Timer operation
Contact your OMRON representative for the datasheet of the S3D2.
3
NL
Connections
Output Circuit Diagrams
NL1 NL2 NL3
Brown (Red) +12 VDC Brown (Red)
Brown (Red)
+24 VDC
4.7 kΩ Load Load
Black
Black
2.2 Ω
Switch Black (White) Output Switch Switch (White)
(White)
100 VAC, 200 VAC
main
main main
Output
Output
circuit circuit circuit
Blue (Black) 0 V Blue (Black) 0 V Blue (Black)
Note: The 0-V power supply side will be connected to the casing if the model is the NL1 or NL2.
External Connection
Sensor Power Supply (S3D2)
Power supply
Applicable model Sensor Controller
The use of the S3D2 is recommended for supplying 12 VDC to the voltage
NL2 (or 24 VDC to the NL2) and converting the output of the NL into
S3D2-AK Basic operation
relay or open collector output in versatile timing control. The NL3 does
Memory and timer
NL1 S3D2-BK
not require a sensor power supply.
operation
S3D2-CK Timer operation
S3D2-AKD Basic operation
NL2
S3D2-CKD Timer operation
S3D2 Controller Unit
Be sure to wire the cable correctly according to the color of each lead wire. Do not wire power lines or high-tension lines alongside the
cable.
The use of S3D2 is recommended as a power supply to the NL1. Contact your OMRON representative for the datasheet of the S3D2.
NL1 NL2
+12 VDC Brown (Red) Blue (Black)
Black 24 VDC
OUT Black (White)
Load
(White)
(Output)
0 V Blue
(Black)
Blue (Black) * 0 V
External circuit
A maximum DC load of 170 mA
* Ground the blue (black) wire.
(with no inductance or resistance).
7 8 9
Can be switched directly.
10 11 12
NL3
Brown (Red)
IN1 IN2
Black
NORM INV
(White)
100 VAC or
Load
4 5 6 (Output) 200 VAC
1 2 3 Blue (Black) *
External circuit
S3D2-AK
A maximum AC load of 300 mA
* Be sure to ground the blue (black)
(cos φ = 1).
line of the NL3.
Can be switched directly.
Note: 1. The lead wire colors of the NL have been changed in compliance with the latest applicable JIS standards. Colors in parentheses are previous ones.
2. The figures in the S3D2 illustration indicate the terminal numbers of the socket.
3. Use a three-conductor cable with a minimum thickness of 0.75 mm to connect the NL and the Sensor Power Supply or other devices with no built-in contacts.
The cable can be extended up to 100 m on condition that the cable is wired in an independent conduit.
4
Brown
(Red)
Black
(White)
Blue
(Black)
NL
Dimensions (Unit: mm)
Built-in Antenna Models
Coil Spring Plunger
NL1-P
NL1-C
1.2 dia. *1 6 dia. *1
5 *2
NL2-P
NL2-C 16
16
5.3 dia.
NL3-P
NL3-C
±2 Two,
110
31
25.8 12.5 +0.12
(15) 1 5.3 dia.
±0.8 holes
6.5
55
(99)
12.5 1
±0.2
75 60
Two,
±0.12
5.3 dia.
8
±0.2
60 holes
75
Two, 5.3-dia.
25 max.
LED operation
long holes
indicator
8 (7.3)
25 max. Two, 5.3-dia.
*3
long holes 7-dia. Connection
15
Caution label 15
(7.3) cable (1 m)
+0.2
5 30
30
+0.8
40 +0.8
*2 43.7
7-dia. Connection
15 15
Caution label
cable (1 m)
*1. The stainless-steel plunger antenna allows a maximum
±0.2
5 30 30
OT (overtravel) of 5 mm.
±0.8 ±0.8
40 43.7 *2. This position is the FP (free position) of the plunger.
*3. Use after removing the caution label.
*1. The coil spring antenna is movable in any direction. Make sure
that the angle of the antenna is within 30° to the FP (free position)
after the antenna comes into contact with the object.
*2. Use after removing the caution label.
Note: 1. The force that pushes the actuator must not exceed 1.96 N. Note: Do not apply a force greater than 9.8 N to the plunger.
2. The antenna is replaceable. Contact your OMRON representative for
details.
Separated Antenna Models
The dimensions provided for the NL1-SP, NL2-SP, NL1-SC, and NL2-SC are the external dimensions for the antennas. The casing
dimensions of these models are all the same as those for the coil spring or plunger models.
No Antenna Plunger Antenna
NL1-S NL1-SP
NL2-S NL2-SP
5 *2
35
(10.5) 31
*1
16 8 22.5 6 R16
6 dia.
*3
*1. The stainless-steel plunger antenna
7 dia. *1
51 allows a maximum OT (overtravel)
of 5 mm.
±0.5
35
Two, M22 x 1
t 2.3 *2. This position is the FP
mounting nuts
(2.3R) (free position) of the plunger.
1 Distance to
Two, *3. A standard 3-m high-frequency
12
(27) opposite side: 26 4.5
()
±0.12
5.3 dia. coaxial cable is provided.
thickness: 4
holes 20
±0.2
16
32
(95)
LED operation
±0.2
60
75 16
indicator
Note: 1. Do not apply a force greater than 9.8 N to the plunger.
Two, 5.3-dia.
2. Do not cut or extend the connecting cable.
long holes
8
(7.3)
25 max.
Coil Spring Antenna
NL1-SC
NL2-SC
*2
7-dia. Connection 15
Caution label 15
cable (1 m)
±0.2
5 30
30
±2
90.5
±0.8
40
±0.8 (10.5)
43.7
±2
31 40.5
86 22.5 3.5
*1. A standard 3-m high-frequency coaxial cable is provided.
*2
*2. Use after removing the caution label. *1. The coil spring antenna is movable in any
direction. Make sure that the angle of the
antenna is within 30° to the FP (free position)
after the antenna comes into contact with the
1.2 dia. *1
object.
*2. A standard 3-m high-frequency coaxial
cable is provided.
Note: 1. Make sure that the shape of the antenna is suitable to the application.
Use the plunger antenna or coil spring antenna as shown right for the
Note: 1. Do not cut or extend the connecting cable.
NL1-S or NL2-S.
2. The antenna is replaceable. Contact your OMRON representative for
2. Do not cut or extend the connecting cable.
details.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
5
NL
Safety Precautions
Refer to Safety Precautions for All Limit Switches.
Antenna
CAUTION
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the NL1SC?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods