Electronics Finder chervon right Manufacturers chervon right O chervon right OMRON AUTOMATION chervon right S82K-00305
About product Specifications Datasheet FAQ

OMRON AUTOMATION S82K-00305

Image of OMRON AUTOMATION S82K-00305

Description

AC/DC Power Supply Single-OUT 5V 0.6A 3W 6-Pin
S82K-00305

Part Number

S82K-00305

Price

Request Quote

Manufacturer

OMRON AUTOMATION

Lead Time

Request Quote

Category

Circuit Protection »  AC-DC Power Supply

Specifications

Manufacturer

Omron Automation

Manufacturers Part #

S82K-00305

Industry Aliases

S82K-00305

Sub-Categories

AC-DC Power Supplies

Factory Pack Quantity

1

Datasheet

pdf file

S82K.pdf

296 KiB

Extracted Text

New S82K Switching Power Supply Ultimate DIN-track-mounting Power Supply with a Wide Power Range from 3 to 240 W Wide power range: 3 to 240 W Wide AC input voltage range: 100 to 240 V on one body. Undervoltage alarm function (indicator) incorpo- rated as standard. (With the 240-W models, applicable only to the “-T” models.) 90 and 100-W models standardized with the alarm output. Output/input terminal parts separated on body upper/bottom side, respectively, for safe and smart wiring. RuCW Multiple pairs of output terminals; Three pairs for 90, 100, and 240-W models Two pairs for 30 and 50-W models Finger-safe terminal block with cover according to VDE0106/P100. Conforms to the stringent EN50081-1 standard for universal use in any environment subject to EMI conditions (except for 240-W models) in addition to EN50082-2 conformity for use at any EMS environment. DC output ports comply to EN55022 class A, thus ensuring use in any environment subject to EMI with recommended external filters (3- to 100-W models). Meets EN61000-3-2 (limits for harmonic current emissions) with PFC on 90, 100, and 240-W models. Parallel running operation (100 and 240-W models). Class 2 approved (except for 240-W models and 7.5-W dual output models). Approvals of various international safety standards for industrial control equipment and industrial computing systems (ITE/TE), in addition to other important approvals. Six-language instruction manual provided. 4 New S82K New S82K Ordering Information 3 to 240-W Models Power oe ratings a gs Output voltage Ou pu o age Output current Ou pu cu e Function Configuration Models ode s Output Undervoltage PFC alarm indicator/output 3 W 3 5 V 0.6 A Single output Sgeou u Ye es s No o S82K-00305 12 V 0.25 A S82K-00312 15 V 0.2 A S82K-00315 24 V 0.13 A S82K-00324 7.5 W 5 5 V 1.5 A S82K-00705 12 V 0.6 A S82K-00712 15 V 0.5 A S82K-00715 24 V 0.3 A S82K-00724 +V12/–V12 0.3 A/0.2 A Dual output ua ou u S82K-00727 +V15/–V15 0.2 A/0.2 A S82K-00728 15 W 5 5 V 2.5 A Single output Sgeou u S82K-01505 12 V 1.2 A S82K-01512 24 V 0.6 A S82K-01524 30 W 5 V 5.0 A S82K-03005 (see note 1) 12 V 2.5 A S82K-03012 24 V 1.3 A S82K-03024 50 W 24 V 2.1 A S82K-05024 90 W 90 24 V 3.75 A 35 Yes S82K-P09024 No S82K-09024 100 W 00 24 V 4.2 A Yes S82K-P10024 (t (see note 2)2) No S82K-10024 240 W 0 24 V 10 A 0 No S82K-24024T (t (see note 3)3) No o Yes S82K-P24024 No S82K-24024 Note: 1. The output capacity of the S82K-03005 is 25 W. 2. The output current during parallel operation is 3.78 A. 3. The output current during parallel operation is 9 A. Model Number Legend S82K - 1 2 3 4 1. Power Factor Correction 3. Output Voltage None:No 05: 05: +5 VDC +5 VDC P: Yes 12: 12: +12 VDC +12 VDC 15: 15: +15 VDC +15 VDC 24: 24: +24 VDC +24 VDC 2. Power Ratings 27: 27: ± ±12 VDC 12 VDC 003: 3 W 28: 28: ± ±15 VDC 15 VDC 007: 7.5 W 015: 15 W 4. Undervoltage alarm indicator/output 030: 30 W 050: 50 W None: Yes 090: 90 W 100: 100 W None:No 240: 240 W T: Yes Accessories (Order Separately) 50 cm (l) � 7.3 mm (t) PFP-50N Mounting ou g Track ac 1 m (l) � 7.3 mm (t) PFP-100N 1 m (l) � 16 mm (t) PFP-100N2 Noise Filter ose e for 3- to 50-W models S82Y-JF3-N for 90-W and 100-W models S82Y-JF6-N 5 New S82K New S82K Specifications Ratings/Characteristics 3- to 240-W models without PFC Single output Dual Single output Item outputs 3 W 7.5 W 7.5 W 15 W 30 W 50 W 90 W 100 W 240 W Efficiency (typical) 60% to 80% (Varies depending on specifications.) Input Voltage AC 100 to 240 V (85 to 264 V) 100 V (85 to 132 V)/ 100 V (85 to (see note 1) 200 V (170 to 264 V) 132 V)/ Selectable 200 V (170 to 253 V) Selectable DC 90 to 350 V (see note 2) Not possible Frequency 50/60 Hz (47 to 450 Hz) Current 0.15 A 0.25 A max. 100-V 0.45 A 0.9 A 1.3 A 2.5 A max. 5.5 A max. (see note 3) () input max. max. max. max. 200-V 0.25 A 0.6 A 0.8 A 1.5 A max. 3.5 A max. input max. max. max. Power factor --- Leakage 100-V 0.5 mA max. current input (t (see note 3)3) 200-V 1 mA max. input Inrush 100-V 15 A max. 25 A max. current input (t (see note 3)3) 200-V 30 A max. 50 A max. input Noise filter Yes Note: 1. Use with DC voltage input is beyond the conditions of approval or conformance to applicable safety standards. 2. Use the 7.5-W single-output models under the load of 90% max. if the voltage range is between 90 and 110 VDC. 3. Defined with a 100 % load and the rated input voltage (100 or 200 VAC). 6 New S82K New S82K 3- to 240-W models without PFC Item Single output Dual Single output outputs 3 W 7.5 W 7.5 W 15 W 30 W 50 W 90 W 100 W 240 W Output Voltage adjustment ±10% (V.ADJ) Not pos- ±10% (V.ADJ); –10% to 15% for S82K-03012/-03024/-05024 (see range sible note 2) (see note 3) Ripple (see note 1) 2% (p-p) max. Input variation 0.5 % max. (at 85 to 264 VAC input, 100% load) 0.5 % max. (at 85 to 0.5 % influence 132 VAC/170 to max. (at 264 VAC input, 100% 85 to load) 132 VAC/ 170 to 253 VAC input, 100% load) Load variation 1.5% max. +V: 1.5% 1.5% max. 1.5% influence (0 to 100% load) max. (0 to 100% load) max. -V: 3 % (10 to max. 100% (0 to load) 100% load) Temperature 0.05%/°C max. variation influence (see note 1) Start up time 100 ms max. (up to 90% of output voltage at rated input and 200 ms max. 300 ms output) max. Hold time 20 ms min. (see note 1) Addi- Overload protection 105% to 160% of 105% to 105% to 160% of rated load 101% to 105% to 160% of tional rated load current, 250% of current, inverted L drop, 111% of rated load current, function inverted L drop, rated automatic reset rated inverted L drop, automatic reset load cur- (30-W, 50-W models: load cur- automatic reset (see note 4) rent, in- inverted L drop, intermittent, rent, in- verted L automatic reset) verted L drop, au- drop, au- tomatic tomatic reset reset (see note 5) Overvoltage No S82K- protection (see note 24024T 6) model only Undervoltage alarm Yes (color: red) S82K- indicator (DC LOW 24024T indicator) model only Undervoltage alarm No Yes S82K- output (DC LOW 24024T output) model only Parallel operation Impossible Possible (2 units max.) (see note 7) Note: 1. Defined with a 100% load and the rated input voltage (100 or 200 VAC). 2. The output specification is defined at the power supply output terminals. 3. The settings for the output voltage must be within the following range: +V: ±1% of the rated value –V: ±5% of the rated value 4. When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the protection function will operate at a current of 95% to 160% of the rated load current. 5. When the ambient temperature exceeds 25°C, the protection function will operate at a current of 92% to 111% of the rated load current. 6. Circuit-breaker type. To reset, turn the input power supply OFF, then after 1 min has elapsed, turn the input power supply ON again. 7. Parallel operation is set with the Parallel/Single Operation Selector Switch. (This setting is not required for S82K–10024 models.) 7 New S82K New S82K 3- to 240-W models without PFC Item Single output Dual Single output outputs 3 W 7.5 W 7.5 W 15 W 30 W 50 W 90 W 100 W 240 W Other Ambient Operating: See the derating curve in the Engineering Data section temperature (no condensation or icing) Storage: –25°C to 65°C (no condensation or icing) Ambient humidity Operating: 25% to 85% Storage: 25% to 90% Dielectric strength 3,000 VAC at 50/60 Hz for 1 min (between all inputs and outputs) 2,000 VAC at 50/60 Hz for 1 min (between all inputs and GR terminal) 1,000 VAC at 50/60 Hz for 1 min (between all outputs and GR terminal) Alarm current: 10 mA (3- to 7.5-W models) 20 mA (15- to 100-W models) 25 mA (240-W models) Insulation 100 MΩ min. at 500 VDC (between all outputs and all inputs/GR terminal) resistance Vibration Malfunction: 10 to 55 Hz, 0.375-mm single amplitude for 2 hrs each in X, Y, and Malfunction: 10 resistance Z directions to 55 Hz, 0.15-mm single amplitude for 2 hrs each in X, Y, and Z directions 2 Shock resistance Malfunction: 300 m/s , 3 times each in ±X, ±Y, and ±Z directions Screw tightening 0.74 N � m max. (see note 2) torque Output indicator Yes (green) Electromagnetic Conforms to FCC class B Conforms to FCC class A interference (see note 1) EMC 3 to 100-W Models (see note 3) (EMI): EN50081-1 Emission Enclosure: EN55022 class B (equivalent to EN55011 class B) Emission AC Mains: EN55022 class B (equivalent to EN55011 class B) Emission Output Ports: EN55022 class A (with a recommended optional filter) (see note 3) 240-W Models (EMI): EN50081-2 Emission Enclosure: EN55011 class A Emission AC Mains: EN55011 class A Common to All Models (EMS): EN50082-2 Immunity ESD: EN61000-4-2: 4-kV contact discharge (level 2) 8-kV air discharge (level 3) Immunity Burst: EN61000-4-4: 2-kV power-line (level 3) 2-kV output line (level 4) Immunity Surge: EN61000-4-5: between 2-kV lines (except for 240-W models) between 4-kV line and FG (except for 240-W models) Approved Class 2 (UL 1310)/Class 2 (CSA C22.2 No. 950) (see notes 4 and 5) UL 508 (Listing)/1012 standards UL 508 (Listing)/1950 CSA C22.2 CSA C22.2 No.14/No.950, EN50178 (VDE0160), EN60950 No.14, CSA E.B. Conforms to VDE0106/P100 1402C, EN50178 (VDE0160), EN60950 Conforms to VDE0106/P100 Weight 150 g max. 260 g 380 g 400 g 600 g max. 1,800 g max. max. max. max. Note: 1. Defined with a 100% load and the rated input voltage (100 or 200 VAC). 2. Do not press down on the terminal block with a force exceeding 75 N while tightening the terminals. 3. To ensure the emission ratings, a noise filter should be used on the output lines at the closest point. (3- to 50-W models: S82Y-JF3-N, 90- and 100-W models: S82Y-JF6-N) 4. Models other than dual output models satisfy the Class-2 requirements. 5. To meet Class-2 requirements with the 100-W model, either a fuse or circuit breaker that is UL listed or CSA certified, and rated at 4.2 A max. should be wired in series with the load to be connected to the power supply. Only then can the power supply output be considered as meeting Class 2. 8 New S82K New S82K 90-/100-/240-W models with PFC (S82K-P���24 models) Single output Item e 90 W 100 W 240 W Efficiency (typical) 60% to 80% (Varies depending on specifications.) Input Voltage 100 V (85 to 132 VAC)/200 V (170 to 264 VAC) 100 to 230 V (85 to 253 VAC) Selectable Frequency 50/60 Hz (47 to 63 Hz) Current 100-V input 2.5 A max. 4 A max. (see (see 200-V input 1.0 A max. 2 A max. note 1) Power oe 100-V input --- 0.95 min. ft factor 200-V input 0.7 min. 0.95 min. Leak- 100-V input 0.5 mA max. age cur- rent rent 200-V input 1 mA max. (see note 1) Inrush 100-V input 25 A max. current current (see 200-V input 50 A max. note 1) Noise filter Yes Output Voltage adjustment ±10% (V.ADJ) (see note ( range 2) 2) Ripple (see note 1) 2% (p-p) max. Input variation 0.5% max. (at 85 to 132 VAC/170 to 264 VAC input, 0.5% max. (at 85 to 253 VAC input, influence 100% load) 100% load) Load variation 1.5% max. (0 to 100% load) 1.5% max. (10 to 100% load) influence Temperature variation 0.05%/°C max. Start up time 200 ms max. 1,000 ms max. Hold time (see note 1) 20 ms min. Addition- Overload protection 101% to 111% of rated 105% to 160% of rated load current, inverted L drop, automatic al func- load current, inverted L reset tion drop, automatic reset (see note 3) Overvoltage No protection Under voltage alarm Yes (color: red) No indicator Under voltage alarm Yes No output Parallel operation Impossible Possible (2 units max.) (see note 4) Note: 1. Defined with a 100% load and the rated input voltage (100 or 200 VAC) 2. The output specification is defined at the power supply output terminals. 3. When the ambient temperature exceeds 25°C, the protection function will operate at a current of 92% to 111% of the rated load current. 4. Parallel operation is set with the Parallel/Single Operation Selector Switch. 9 New S82K New S82K 90-/100-/240-W models with PFC (S82K-P���24 models) Single output Item e 90 W 100 W 240 W Other Ambient temperature Operating: See the derating curve in the Engineering Data section (No condensation or icing) Storage: –25°C to 65°C (no condensation or icing) Ambient humidity Operating: 25% to 85% Storage: 25% to 90% Dielectric strength 3,000 VAC at 50/60 Hz for 1 min. (between all inputs and outputs) 2,000 VAC at 50/60 Hz for 1 min. (between all inputs and GR terminal) 1,000 VAC at 50/60 Hz for 1 min. (between all outputs and GR terminal) Alarm current: 20 mA (90- and 100-W models) 25 mA (240-W models) Insulation resistance 100 MΩ min. at 500 VDC (between all outputs and all inputs/GR terminal) Vibration resistance Malfunction:10 to 55 Hz, 0.375-mm single amplitude for Malfunction:10 to 55 Hz, 0.15-mm 2 hrs each in X, Y, and Z directions single amplitude for 2 hrs each in X, Y, and Z directions 2 2 Shock resistance Malfunction:150 m/s , 3 times each in ±X, ±Y, and ±Z Malfunction:300 m/s , 3 times each in directions ±X, ±Y, and ±Z directions Screw tightening 0.74 N � m max. (see note 2) torque Output indicator Yes (Green) Electromagnetic Conforms to FCC class A interference (see note 1) EMC (see note 3, 4) 90-, 100-W Models (EMI): EN50081-1 Harmonic Current: EN61000-3-2 (200 VAC input only) Emission Enclosure: EN55022 class B Emission AC Mains: EN55022 class B Emission Output Ports: EN55022 class A (with a recommended optional filter) (see note 3) 240-W Model (EMI): EN50081-2 Harmonic Current: EN61000-3-2 Emission Enclosure: EN55011 class A (see note 4) Emission AC Mains: EN55011 class A Common to All Models (EMS): EN50082-2 Immunity ESD: EN61000-4-2: 4-kV contact discharge (level 2) 8-kV air discharge (level 3) Immunity Burst: EN61000-4-4: 2-kV power-line (level 3) 2-kV output line (level 4) Immunity Surge: EN61000-4-5: between 2-kV lines (except for 240-W models) between 4-kV line and FG (except for 240-W models) Approved standards Class 2 (UL1310)/Class 2 (CSA C22.2 No. 950) (see UL508 (Listing)/1012 note 5) CSA C22.2 No. 14/E.B. 1402C, UL508 (Listing)/1950 EN50178 (VDE0160), EN60950, CSA C22.2 No. 14/No. 950, EN50178 (VDE0160), Conforms to VDE0106/P100 EN60950 Conforms to VDE0106/P100 Weight 1,000 g max. 2,200 g max. Note: 1. Defined with a 100% load and the rated input voltage (100 or 200 VAC) 2. Do not press down on the terminal block with a force exceeding 75 N while tightening the terminals. 3. To ensure the Emission Enclosure ratings, a noise filter should be used on the output lines at the closest point. (90- and 100-W models: S82Y-JF6-N) 4. To ensure the Emission Enclosure rating, a ferrite ring core should be used on all cables. 5. To meet Class-2 requirements with the 100-W model, either a fuse or circuit breaker that is UL listed or CSA certified, and rated at 4.2 A max. should be wired in series with the load to be connected to the power supply. Only then can the power supply output be considered as meeting Class 2. 10 New S82K New S82K Reference Value Item Value Definition Reliability (MTBF) 135,000 hrs min. MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates reliability of devices. Therefore, it does not necessarily represent a life of the product. Life expectancy 8 yrs. min. The life expectancy indicates average operating hours under the ambient temperature of 40°C and a load rate of 50%. Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor. Engineering Data Derating Curve 3-/7.5-/15-/30-/50-/100-W Models 100-W Models without PFC 100-W Models with PFC Single-Unit Operation Parallel-Unit Operation Parallel-Unit Operation Installation A Installation A 90 Installation B Installation A S82K-P10024: 85-VAC input 65 65 S82K-P10024: 85-VAC input Installation B S82K-03005 Installation B Installation A Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C) Note: When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the load rate will become 90% or less. 90-W Models 240-W Model 240-W Model Parallel-Unit Operation Single-Unit Operation Single-Unit Operation Installation A Installation A 90 S82K-P09024: 85-VAC input 70 Installation A 65 S82K-P24024: 100-VAC input (see note) S82K-P24024: 100-VAC input Installation B (see note) Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C) Note: 100-VAC input: 85 to 132 VAC Note: 100-VAC input: 85 to 132 VAC 11 Load (%) Load (%) Load (%) Load (%) Load (%) Load (%) New S82K New S82K (A) Standard (Vertical) Installation (B) Horizontal Installation Top Top (Not permitted for S82K-�� 240-W models.) Note: The derating curve above can be ensured for the above two kinds of installations. 12 New S82K New S82K Overload Protection The Power Supply is provided with an overload protection function that protects the load and the power supply from possible damage by over- current. When the output current rises above a set value (refer to the table below), the protection function is triggered, decreasing the output voltage. When the output current falls within the rated range, the overload protection function is automatically cleared. Single output Dual Single output outputs 3 W 7.5 W 7.5 W 15 W 30 W 50 W 90 W 100 W 240 W Set value 105% to 160% of rated 105% to 105% to 160% of rated load current 101% to 105% to 160% of rated load current (see note 1) 250% of 111% of load current (see note 3) rated load rated load current current (see notes 2 and 3) Operation Inverted L drop type, automatic reset Inverted L Inverted L drop type, automatic reset drop/intermittent operation type, automatic reset Note: 1. When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the overload protection func- tion will operate at currents from 95% to 160% of the rated load current. 2. When using the 90-W model at an ambient temperature exceeding 25°C, the overload protection function will operate at currents from 92% to 111% of the rated load current. 3. When using the 100-W model with PFC in parallel operation, the overload protection function will operate at currents from 3.78 to 4.2 A. 3-/7.5-/15-/90-/100-/240-W Models 30-/50-W Models Rated voltage Rated voltage Intermittent operation 0 50 100 Output current (%) Output current (%) Note: Do not short-circuit the output terminals of the S82K or use the S82K with excessive output current for a long time, otherwise the internal circuitry of the S82K may be deteriorated or damaged. When Using ± Output Models The +V output detects the total output power (+V output and -V output) to trigger the short-circuit protection against overcurrent. This protection varies depending on the -V output state. The -V output independently triggers the short-circuit protection. 13 Output voltage (V) Output voltage (V) New S82K New S82K Overvoltage Protection (S82K-24024T Models Only) The Power Supply is provided with an overvoltage protection function that protects the load and the Power Supply from possible damage by overvoltage. When the output voltage rises above a set value, the protection function is triggered, shutting off the output voltage. If this occurs, reset the Power Supply by turning it off for 1 minute min. and then turning it on again. Overvoltage protection operating 10% Rated output voltage Variable range –10% Inrush Current, Start up Time, Hold Time Input OFF Input ON AC input voltage Inrush current on input application AC input current 90% 96.5% Output voltage Start up time: 100 to 1000 ms Hold time max. depending on the model. (20 ms min.) 14 Output voltage (V) New S82K New S82K Operation Undervoltage Alarm Indicator and Output Function (All Models Except for S82K-24024/P24024) If the output voltage at the output terminal drops to 75% to 90% of the rated voltage, the red indicator of the S82K (DC LOW indicator) will be lit. In the case of the S82K-�09024/�10024/24024T, a voltage drop alarm will be output via the relay available in the models (DC LOW output). Note: This function detects the voltage at the output terminal of the Power Supply. To check the precise output voltage, measure the voltage at the terminal of the load. Indicator Voltage Operation of �09024/�10024/ 24024T’s output (DC LOW output) (see note 2) Green: DC ON If the voltage at the output terminal is more than 82% of the rated voltage and operation is normal, the Red: DC LOW green indicator will be lit and the red indicator will not be lit. Green: DC ON If the voltage at the output terminal drops to below (see note 1) 82% of the rated voltage, the red indicator will be lit. Red: DC LOW (See note 3.) Green: DC ON If the voltage at the output terminal approaches 0 V, both the green and red indicators will not be lit. Red: DC LOW Note: 1. The more the voltage at the output terminal drops, the darker both the green and red indicators will be. 2. The relay contacts have a capacity of 0.1 A at 24 VDC. 3. The red indicator will actually first light at a voltage between 75% and 90% of the rated voltage. Block Diagrams S82K-003�� (3 W) S82K-007�� (7.5 W, Single Output) Fuse (1 A) AC (L) + V Noise filter AC (N) – V Inrush current Rectifier Rectifier protection circuit Undervoltage Drive control alarm circuit indicator Overload Detector alarm circuit Photocoupler S82K-007�� (7.5 W, Dual Outputs) Fuse (1 A) AC (L) – V Noise filter AC (N) Inrush current Rectifier 3-terminal Rectifier protection circuit REG + V Undervoltage Drive control alarm circuit indicator Rectifier Overload Detector alarm circuit Photocoupler 15 New S82K New S82K S82K-015�� (15 W) S82K-030�� (30 W) S82K-05024 (50 W) Fuse (3 A) + V AC (L) Noise filter AC (N) – V Inrush current Rectifier Rectifier protection circuit Undervoltage Drive control alarm circuit indicator Overload Detector alarm circuit Photocoupler S82K-09024 (90 W) S82K-10024 (100 W) Fuse (5 A) Rectifier + V AC (L) Noise filter AC (N) – V Inrush current Rectifier protection circuit 100 or 200 V Selectable terminals (see note) Drive control circuit Undervoltage alarm indicator Overload alarm Detector circuit Photocoupler Note: Use the short bar to short-circuit terminals 7 and 8 to select 100 to 120 VAC and remove the short bar to select 200 to 240 VAC. S82K-P09024 (90 W) S82K-P10024 (100 W) Harmonic current emission control Inrush current (200-V input only) Fuse (5 A) protection circuit Rectifier + V AC (L) Noise filter AC (N) – V Rectifier 100 or 200 V Selectable terminals (see note) Drive control circuit Undervoltage alarm indicator Overload Detector alarm circuit Photocoupler Note: Use the short bar to short-circuit terminals 7 and 8 to select 100 to 120 VAC and remove the short bar to select 200 to 240 VAC. 16 New S82K New S82K S82K-24024� (240 W) Fuse (5 A) AC (L) INPUT Noise filter AC (N) + V Inrush current Rectifier DC protection circuit 100 or 200 V OUTPUT Selectable – V terminals Rectifier (see note 2) Drive control circuit Detector DC LOW Photocoupler Undervoltage alarm Overload alarm Overvoltage indicator/output circuit alarm circuit (see note 1) Overvoltage protection circuitry (see note 1) Note: 1. The overvoltage protection circuitry and undervoltage alarm indicator are avail- able in the S82K-24024T only. 2. Use the short bar to short-circuit terminals 7 and 8 to select 100 to 120 VAC and remove the short bar to select 200 to 230 VAC. S82K-P24024 (240 W) Fuse (8 A) AC (L) + V DC INPUT Noise filter OUTPUT AC (N) – V Harmonic current Smoothing Rectifier Inrush current Rectifier emission control protection circuit Drive control circuit Overload alarm Detector circuit Photocoupler 17 New S82K New S82K Dimensions Note: All units are in millimeters unless otherwise indicated. S82K-003�� (3 W) Mounting Brackets S82K-007�� (7.5 W) (Supplied with the Switching Power Supply) Used when not mounting the Power Supply directly on the DIN track. Two, 4.5± dia. 0.1 35± 25± 0.15 0.15 27± 0.1 37.5± 0.1 Mounting Holes Attached Mounting Bracket M3.5 with square washer (sliding 7 max.) M4 or 4.5-dia. hole Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. S82K-015�� (15 W) 45 9.8 8.3 7.5 45 35 75 58.1 91 5 4.6 M3.5 with square (sliding 7 max.) washer Mounting Holes Two, M4 or 4.5-dia. mounting holes Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each 60 adjacent Power Supply. L 35 18 New S82K New S82K S82K-030�� (30 W) S82K-05024 (50 W) Four, 4.5 dia. 35 M3.5 with square washer 4 (sliding 7 max.) Mounting Holes Four, M4 or 4.5-dia. mounting holes Note: If more than one Power Supply is installed in a row, keep a distance of 60 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. L 80 S82K-�09024 (90 W) S82K-�10024 (100 W) 145 Four, 4.5 dia. 135±0.2 9.8 8.3 7.5 45 35 58.1 75 60±0.2 91 5 M3.5 terminal screw M3.5 with square washer 4 (sliding 7 max.) Short bar Mounting Holes Four, M4 or 4.5-dia. mounting holes Note: If more than one Power Supply is 60 installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. L 135 19 New S82K New S82K 280 270±0.2 S82K-�24024� Four, 4.5 dia. 7.8 9.8 8.3 27.5 112.8 100 35 130 115±0.2 4.2 138 M3.5 terminal screw 4 M3.5 with square washer (sliding 8 max.) Short bar Mounting Holes L 270 115±0.2 Four, M4 or 4.5-dia. mounting holes Note: If more than one Power Supply is installed in a row, keep a distance of 20 mm min. (L = 20 mm min.) between each adjacent Power Supply. Accessories Mounting Track (Order Separately) PFP-100N/PFP-50N PFP-100N2 16 7.3±0.15 4.5 4.5 27 24 29.2 35±0.3 27±0.15 35±0.3 15 25 25 25 25 15 15 25 25 25 25 1 1.5 1 10 10 10 10 15 (5) 1,000 (500) 1,000 (see note) (see note) Note: The values shown in parentheses are for the PFP-50N. Noise Filter (Order Separately) S82Y-JF3-N for 3- to 50-W Models Two, 4.8 dia. A max. (Mounting 16 max. S82Y-JF6-N for 90- and 100-W Models 16 max. B±1 D±1 holes) 4 39±0.5 Nameplate 47±1 4 6.5 Six, M4 6.5 C±0.5 Model A B C D S82Y-JF3-N 107 75 90 26 S82Y-JF6-N 117 85 100 30 20 New S82K New S82K Installation S82K-003��/S82K-007�� S82K-007�� (Dual outputs) S82K-015�� (Single Output) 11 1 1 5 5 5 7 7 7 6 6 23 23 23 S82K-�09024/S82K-�10024 S82K-030��/S82K-05024 1 8 1 5 5 7 7 6 6 23 234 Bottom view 67 5 8 1 S82K-�24024� (Only for S82K-P10024) 9 234 Bottom view 1. DC Output Terminals: Connect the load lines to these terminals. 2. Input Terminals: Connect the input lines to these terminals. 3. Ground Terminal (GR): Connect a ground line to this terminal. 4. Input Voltage Selector Terminals: Selects a 100 V or 200 V input voltage. 5. Output Indicator (DC ON): Lights while a Direct Current (DC) output is ON. 6. Output Voltage Adjuster(V.ADJ): It is possible to increase or decrease the output voltage. 7. Undervoltage Alarm Indicator (DC LOW): Other than S82K-24024 and S82K-P24024 models. 8. Undervoltage Alarm Output (DC LOW): S82K-�09024/-�10024/-24024T models only. 9 9. Parallel/Single Operation Selector: Set to “PARALLEL” or “P” for parallel operation. 21 New S82K New S82K Precautions ! To dismount the Power Supply, pull down portion (C) with a flat- Caution blade screwdriver and pull out the Power Supply. Be sure to connect the grounding line. Not doing so may result in electric shock. ! WARNING Do not attempt to disassemble the Power Supply or touch its internal parts while power is being supplied. Doing so may re- sult in electric shock. Do not touch the terminals of the Power Supply within one min- 30 mm min. ute after power has been turned OFF. Doing so may result in C electric shock due to a residual voltage. Track stopper Do not touch the Power Supply Unit while power is being sup- plied or immediately after power has been turned OFF. Doing When tightening the terminals, do not tighten the terminal block to a so may result in a skin burn due to high temperature of the torque greater than 75 N. Power Supply. Selection of 100 or 200 VAC Input Voltage (S82K-�09024/-�10024/-24024/-24024T) Mounting Select a 100 V or 200 V input by shorting or opening the Input Volt- To improve and maintain the reliability of the Power Supply over a age Selector Terminals, as shown in the following diagram. long period of time, adequate consideration must be given to heat The default setting is 200 V. radiation. The Power Supply is designed to radiate heat by means of natural 100 V Input air-flow. Therefore, mount the Power Supply so that air flow takes place around the Power Supply. Use the short bar to short-circuit terminals 7 and 8. Air 200 V Input When mounting two or more Power Supplies side-by-side, allow at least 10 mm spacing between them, as shown in the following il- lustration. Forced air-cooling is recommended. 10 mm min. Remove the short bar. Generating Output Voltage (±) An output of ± can be generated by using two Power Supplies as shown below, because the Power Supply produces a floating out- put. +V Short bar INPUT –V To mount the Power Supply on a DIN track, hook portion (A) of the Power Supply to the track and press the Power Supply toward direc- tion (B). +V INPUT –V (A) When connecting the Power Supplies in series with an operation amplifier, connect diodes to the output terminals as shown by the dotted lines in the figure. No diodes are required with S82K 90-W/100-W/240-W models. (B) 22 New S82K New S82K Wiring Parallel Operation Carefully wire the input/output terminals while paying attention to S82K 100-W/240-W models can be operated in parallel. their polarities so as to prevent incorrect wiring. Perform parallel operation with power supplies satisfying the same specifications. Battery Charging/Backup With S82K-�09024/-�10024/-24024T models, a reduction in life- 100- and 240-W Models time due to over discharge of the battery can be prevented using the DC LOW output. (Discharge can be interrupted at 0.75 to 0.9 × +V 24 V.) INPUT Load –V Example: Lead Storage Battery Backup Circuit 14 +V INPUT 15 +V –V Fuse/Circuit breaker 16 Note: When operating the S82K-P10024 or S82K-�24024� in parallel operation, set the switch to “PARALLEL.” Refer to the derating curve for the rated current under this operation. 9 DC Low 10 11 12 –V 3-, 7.5-, 15-, 30-, 50- and 90-W Models 13 +V INPUT Load –V Note: 1. For details of charging voltages and charging currents, refer to the specifications for the battery. 2. In order to prevent overvoltage to the battery, install an overvoltage protection circuit (90/100-W models). +V 3. To protect the battery in the event of incorrect operation, INPUT such as load short-circuiting, be sure to install a fuse or –V circuit breaker. 4. To limit the level of charging current to the battery, install an overcurrent limit circuit. Parallel Operation Precautions With other models, when connecting a battery to the load, install an • The length and thickness of each wire connected to the load overcurrent limit circuit and overvoltage protection circuit. must be the same so that there is no difference in voltage drop value between the load and the output terminals of each Power Series Operation Supply. S82K 90-W/100-W/240-W model can be operated in series. It must be noted that the + output of the 7.5-W dual output model • Adjust the output voltage of each Power Supply so that there will cannot be connected in series to its – output. be no difference in output voltage between each Power Supply. • If the S82K-P10024 or S82K-�24024� models are used in 90-, 100-, and 240-W Models single operation under the parallel operation setting, the overcurrent protection will be actuated at an output of 90% to +V 95% (in current), and will not allow a 100% output. INPUT –V • If the S82K-P10024 or S82K-�24024� models are used in parallel operation under the single operation setting, one of them will operate at 110% output, causing severe heat derating and shortening the service life. +V INPUT –V 3-, 7.5-, 15-, 30-, 50-W Models +V INPUT –V +V INPUT –V 23 Overvoltage protection circuit Overcurrent limit circuit Load New S82K New S82K Minimum Output Current The minimum output current of the S82K-00727 and S82K-00728 is restricted by the output voltage and control method. Note: All the outputs of the S82K-00727 and S82K-00728 are controlled by the +V output. If the +V output current falls to 10% or less of the rated output, the –V output voltage may drop. Operating and Storage Environments Do not use or store the Unit in the following places, otherwise the Unit may malfunction or the characteristics of the Unit may deterio- rate. • Locations subject to direct sunlight. • Locations subject to ambient operating temperatures outside the range indicated by the derating curve. • Locations subject to ambient operating humidity outside the range of 25% to 85%. • Locations subject to condensation as the result of severe changes in temperature. • Locations subject to ambient storage temperatures outside the range of –25°C to 65°C. • Locations subject to corrosive or flammable gases. • Locations subject to dust (especially iron dust) or salts. • Locations subject to shock or vibration. • Locations subject to exposure to water, oil, or chemicals. 24 New S82K New S82K ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. M048-E1-05B In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company Measuring and Control Division Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Printed in Japan Tel: (81)75-344-7108/Fax: (81)75-344-7189 1001-1M (O) 25

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the S82K-00305?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

AC/DC Power Supply Single-OUT 12V 27A 300W Medical 12-Pin S82D-3012

product

AC/DC Power Supply Single-OUT 12V 1.2A 15W S82H-3112

product

AC/DC Power Supply Single-OUT 24V 2.3A 50W Medical S82H-3524

product

AC/DC Power Supply Single-OUT 12V 1A 10W 5-Pin S82J01012D

product

AC/DC Power Supply Single-OUT 24V 0.5A 10W 5-Pin S82J-01024A

product

AC/DC Power Supply Single-OUT 5V 5A 25W S82J-0205