OMRON AUTOMATION Y92H-2
Specifications
Manufacturer
Omron Automation
Manufacturers Part #
Y92H-2
Lead Time
4 Week Lead Time
Industry Aliases
Y92H-2
Sub-Categories
Miscellaneous Tools and Supplies
Factory Pack Quantity
1
Datasheet
Extracted Text
Motor Timer H2C Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and Application Considerations (page 12), and Safety Precautions (page 10). DIN-sized (48 x 48, 45 x 75 mm) Motor Timer with Variable Time Ranges • Five time ranges are selectable per timer unit. Easy-to-monitor neon lamp for timing operation indication (for 110, 120, 220, 240 VAC types only). Easy-to-set large transparent knob and easy-to-read single pat- tern scale facilitate time setting. Equipped with timing operation indicator and moving pointer. Conforms to EN61812-1 and IEC60664-1 4 kV/1 for Low Volt- age, and EMC Directives (except for H2C-F@). Model Number Structure ■ Model Number Legend H2C-@ @ 12 1. External Connection/Attachment 2. Operation/Resetting System None: 11-pin socket None: Time-limit operation/self-resetting S: 11-pin socket/time setting ring R: Time-limit operation/electric resetting 8: 8-pin socket F: Front screw Ordering Information ■ List of Models Operation/resetting Internal Terminal Time-limit Instantaneous Attachment Model system connection contact contact Time-limit operation/ Parallel motor and 8-pin socket SPDT SPDT --- H2C-8 self-resetting clutch connection Separate motor 11-pin socket H2C and clutch connec- Y92A-Y1 Time Set- H2C-S tion ting Ring Front screw --- H2C-F Time-limit operation/ 8-pin socket SPDT --- --- H2C-8R electric resetting 11-pin socket SPDT H2C-R Y92A-Y1 Time Set- H2C-SR ting Ring Front screw --- H2C-FR Note: Specify both the supply voltage and time range code (A, B, or C) in addition to the model number when ordering. Example: H2C-S 24 VAC B Time range code Supply voltage Motor Timer H2C 1 Discontinued ■ Accessories (Order Separately) Name/specifications Models Flush Mounting Adapter Y92F-30 Time Setting Ring (See note 1.) Y92A-Y1 Mounting Track 50 cm (l) � 7.3 mm (t) PFP-50N 1 m (l) � 7.3 mm (t) PFP-100N 1 m (l) � 16 mm (t) PFP-100N2 End Plate PFP-M Spacer PFP-S Protective Cover Y92A-48B Track Mounting/Front Connecting 8-pin P2CF-08 Socket 8-pin, finger safe type P2CF-08-E 11-pin P2CF-11 11-pin, finger safe type P2CF-11-E Back Connecting Socket 8-pin, screw terminal P3G-08 8-pin, finger safe type P3G-08 with Y92A-48G (See note 2.) 11-pin P3GA-11 11-pin, finger safe type P3GA-11 with Y92A-48G (See note 2.) Hold-down Clip (See note 3.) For PL08 and PL11 Sockets Y92H-1 For PF085A Socket Y92H-2 Note: 1. Supplied with H2C-S/-SR models. 2. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 or P3GA-11 Socket. 3. Hold-down Clips are sold in sets of two. Specifications ■ Time Ranges Five time ranges are available for each timer by turning the time range selector every 60 degrees. Note: Rated time is displayed on the window. Time range code Position of time range selector A 1.25 to 30 s 7.5 s to 3 min 1.25 to 30 min 7.5 min to 3 h 1.25 to 30 h B 0.2 to 6 s 2 to 60 s 0.2 to 6 min 2 to 60 min 0.2 to 6 h C 0.5 to 12 s 5 to 120 s 0.5 to 12 min 5 to 120 min 0.5 to 12 h ■ Ratings Item H2C Rated supply voltage (motor and 24, 48, 100, 110, 115, 120, 200, 220, or 240 VAC (50/60 Hz) (see note) clutch) Operating voltage range 85% to 110% of rated supply voltage Power consumption 4.2 VA max. (3.96 W max.) Reset voltage 10% max. of rated supply voltage Reset time Minimum power-opening time:0.5 s Minimum pulse width: 0.5 s Control outputs 6 A at 250 VAC, resistive load (cosφ = 1) Mounting method Flush mounting (except for H2C-F/-FR models), surface mounting, DIN track mounting Note: The front panel of the timer is color coded to identify the following supply voltage classifications: 100 to 120 V: Blue 200 to 240 V: Red Other classes: Black 2 Motor Timer H2C Discontinued ■ Characteristics Accuracy of operating time ±0.5% FS max. �±1% max. at 0.2 to 6 s for the time range code B or at 0.5 to 12 s for the time range code C) Setting error ±2% FS max. Reset time 0.5 s max. Influence of voltage ±1% FS max. Influence of temperature ±2% FS max. Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts) 2,000 VAC, 50/60 Hz for 1 min (between contact and control circuit and between contacts of different polarities) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Vibration resistance Destruction: 10 to 55 Hz with 0.375-mm single amplitude for 1 h each in three directions Malfunction: 10 to 55 Hz with 0.25-mm single amplitude for 10 min each in three directions 2 Shock resistance Destruction: 1,000 m/s 2 Malfunction: 150 m/s Ambient temperature Operating: –10°C to 50°C Storage: –25°C to 65°C Ambient humidity Operating: 45% to 85% Life expectancy Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h) Electrical: 500,000 operations min. (3 A at 250 VAC, resistive load at 1,800 operations/h) See Life-test Curve for other details. Motor life expectancy 20,000 h Approved standards UL917, CSA C22.2 No.14. Conforms to EN61812-1 and IEC60664-1 4 kV/1 (except for H2C-F@ models). Output category according to EN60947-5-1 (except for H2C-F@ models). EMC (except for H2C-F@ models) (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A (EMS) EN61812-1 Immunity ESD: IEC61000-4-2: 6 kV contact discharge (level 3) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: IEC61000-4-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Immunity Surge: IEC61000-4-5: 1 kV line to line (level 3) 2 kV line to ground (level 3) Case color Light gray (Munsell 5Y7/1) Degree of protection IP40 (panel surface) Weight H2C series: approx. 180 g H2C-F series: approx. 270 g ■ Life-test Curve 300 300 200 200 100 100 250 VAC cosφ = 1 50 50 24 VDC cosφ = 1 40 40 30 30 250 VAC cosφ = 0.4 20 20 24 VDC L/R = 7 msec 10 10 5 5 12 3 4 5 6 1 2 3 456 Load current (A) Load current (A) Motor Timer H2C 3 Discontinued 4 Switching operations (x 10 ) 4 Switching operations (x 10 ) Connections ■ Terminal Arrangement Note: The connections diagrams are for when the clutch is in the excited, reset state. H2C-8 H2C-8R H2C(-F)/H2C-S H2C-(F)R/H2C-SR Clutch coil Clutch coil (B2) 6 6 (B1) 5 7 5 7 (16) (B2) (B2) (22) (B1) (B1) 8 (18) 8 (16) 4 4 (16) (24) (22) (22) (A1) (18) (A2) 9 (18) 3 (24) 9 (15) (21) (24) 3 (A1) (A2) (A1) (A2) 10 2 10 (21) (15) 2 (21) (15) 11 1 1 11 (DIN 46 199-5) (DIN 46 199-5) 4 Motor Timer H2C Discontinued Operation ■ Timing Chart Power failure H2C-8 H2C-8R Rt time (t') Rt Rt tt Rt Rt t Power (2-7) Power and motor (2-7) Time-limit contacts t+t' NC (8-5) Power and clutch (1-4) Time-limit contacts NO (8-6) Time-limit contacts Instantaneous contacts NC (8-5) NC (1-4) Time-limit contacts Instantaneous contacts NO (8-6) NO (1-3) Timing operation indicator Timing operation indicator lamp (OFF at time-up) lamp (OFF at time-up) Rt: Resetting time Rt: Resetting time Power failure time (t') H2C(-F)/H2C-S H2C-(F)R/H2C-SR Rt Rt Rt t Rt t tRt Power and motor Power and motor 2(A1)-10(A2) 2(A1)-10(A2) t+t' Power and clutch Power and clutch 7(B1)-6(B2) 7(B1)-6(B2) Time-limit contacts Time-limit contacts NC 1(15)-4(16) NC 1(15)-4(16) Time-limit contacts Time-limit contacts NO 1(15)-3(18) NO 1(15)-3(18) Instantaneous contacts Instantaneous contacts NC 11(21)-8(22) NC 11(21)-8(22) Instantaneous contacts Instantaneous contacts NO 11(21)-9(24) NO 11(21)-9(24) Timing operation indicator Timing operation indicator lamp (OFF at time-up) lamp (OFF at time-up) (See note.) (See note.) Rt: Resetting time Rt: Resetting time Note: For the types rated at 24 and 48 VAC, the timing operation indicator is not equipped. Nomenclature Timing operation Time range indicator selector Rated voltage color code Motor Timer H2C 5 Discontinued Dimensions Note: All units are in millimeters unless otherwise indicated. H2C/H2C-S/H2C-R/H2C-SR/H2C-8/H2C-8R For Flush Mounting +0.6 45 −0 44.8 x 44.8 37 dia. +0.6 45 −0 For a load current of 3 A max., dimension L becomes 3 mm min. with an interval of 0 mm between timers. For a load current of 6 A max., dimension L becomes 8 mm min. with an interval of 5 mm between timers. When using in locations with high ambient temperatures, ensure that there is an interval of at least 5 mm between timers. Mounting Holes H2C-F/H2C-FR Two, M4 or 4.5 dia. holes For a load current of 1 A max., dimension L becomes 10 mm min. with an interval of 0 mm between timers. For a load current of 3 A max., dimension L becomes 15 mm min. with an interval of 5 mm between timers. For a load current of 6 A max., dimension L becomes 20 mm min. with an interval of 10 mm between timers. Dimensions with Front Connecting Socket Dimensions with Back Connecting Socket P2CF-08-@/P2CF-11-@ P3G-08/P3GA-11 92.2 81.5 16.3 16.3 80 85.7 H2C H2C-S H2C-8 H2C H2C-R H2C-8 H2C-8R H2C-S H2C-SR 103.1* H2C-R H2C-8R 100.8* H2C-SR + + Adapter Adapter P3G-08 P3GA-11 Y92F-30 Y92F-30 (When (When Y92A-48G Y92A-48G P2CF-11 P2CF-08 mounted) mounted) P2CF-11-E P2CF-08-E *These dimensions vary with the kind of DIN track (reference value). 6 Motor Timer H2C Discontinued ■ Accessories (Order Separately) Adapter for Flush Mounting Y92F-30 Track Mounting/Front Connecting Socket P2CF-08 Eight, 34.5 M3.5 x 7.5 sems 7.8 70 max. 35.4 Terminal Arrangement/ Two, 4.5 dia. holes Internal Connections (Top View) Surface Mounting Holes 4 50 max. Two, 4.5 dia. or two, M4 20.3 max. P2CF-08-E (Finger Safe Terminal Type) Conforming to VDE0106/P100 40±0.2 Eight, 54.5 M3.5 x 7.5 sems 7.8 3 1.3 70 max. 35.4 Two, 4.5 dia. holes 4 40±0.2 19 20.3 50 max. 21.5 max. Motor Timer H2C 7 Discontinued Track Mounting/Front Connecting Socket P2CF-11 34.5 Eleven, 7.8 M3.5 x 7.5 sems Terminal Arrangement/ 70 max. 35.4 Internal Connections (Top View) Surface Mounting Holes Two, 4.5 dia. holes Two, 4.5 dia. or two, M4 4 50 max. 31.2 max. 40±0.2 P2CF-11-E (Finger Safe Terminal Type) Conforming to VDE0106/P100 Eleven, M3.5 x 7.5 sems 7.8 54.5 3 1.2 35.4 70 max. Two, 4.5 dia. holes 4 40±0.2 30 50 max. 31.2 max. Back Connecting Socket Terminal Arrangement/ P3G-08 27 dia. Internal Connections (Bottom View) 45 45 4.9 17 P3GA-11 Terminal Arrangement/ 27 dia. Internal Connections (Bottom View) 45 25.6 45 4.5 6.2 16.3 Finger Safe Terminal Cover Conforming to VDE0106/P100 Y92A-48G Twelve, 6.4 dia. holes (Attachment for P3G-08/ P3GA-11 Socket) 48 x 48 34 47.7 x 47.7 16.5 24.6 27.6 47.4 8 Motor Timer H2C Discontinued Mounting Track PFP-100N, PFP-50N PFP-100N2 16 7.3±0.15 4.5 4.5 27 29.2 24 35±0.3 27±0.15 35±0.3 15 25 25 25 25 15 15 25 25 25 25 11.5 15 (5) 1 10 10 10 10 1,000 (500) (see note) 1,000 (see note) Note: The value shown in parentheses are for the PFP-50N. End Plate Spacer PFP-M PFP-S 16 10 5 12 6.2 1.8 1 35.5 35.3 34.8 50 44.3 1.8 11.5 1.3 M4 x 8 10 4.8 pan head 16.5 screw Time Setting Ring Protective Cover Y92A-Y1 Y92A-48B The protective cover shields the front panel, particular- The time setting ring locks the time setting knob to ly the time setting section, from dust, dirt, and water, store the set time to facilitate its resetting. A maximum as well as prevents the set value from being altered of two time setting rings are connectable per timer. due to accidental contact with the time setting knob. Timer Hold-down Clips Y92H-1 Y92H-2 (for PL08/PL11 (for PF085A/PF113A Connecting Socket) Connecting Socket) Motor Timer H2C 9 Discontinued Safety Precautions ■ Precautions for Correct Use !CAUTION This may occasionally cause electric shock, fire, or malfunction. How to Change the Time Range Never disassemble, repair, or modify the H2C. Change the time range by turning the knob clockwise using a flat- This may occasionally cause electric shock, fire, or malfunction. blade screwdriver or an Allen wrench. There are five possible Do not allow metal fragments or lead wire scraps to fall inside the settings. The selected time is displayed in the time range display H2C. window above the knob. ■ Precautions for Safe Use Observe the following items to ensure the safe use of this product. Time range display window Environmental Precautions • Store the H2C within the specified ratings. If the H2C has been stored at temperatures –10°C or lower, let it stand for 3 hours or Hex. hole for Groove for flat- longer at room temperature before turning ON the power supply. Allen wrench blade screwdriver Use the H2C within the specified ratings for operating temperature Do not change the time range while the timer is in operation. and humidity. Do not operate the H2C in locations subject to sudden or extreme How to Select Power Frequency changes in temperature, or locations where high humidity may result in condensation. Before using the timer, set the frequency selector located at the rear Do not use the H2C in locations subject to vibrations or shock. panel to the proper power frequency (50 to 60 Hz). Extended use in such locations may result in damage due to stress. Do not use the H2C in locations subject to excessive dust, corrosive gas, or direct sunlight. Install the H2C well away from any sources of static electricity, such as pipes transporting molding materials, powders, or liquids. 50 Hz The H2C is not waterproof or oil resistant. Do not use it in locations subject to water or oil. The life expectancy of internal components may be reduced if the 60 Hz H2C is mounted side-by-side. Do not use organic solvents (such as paint thinner or benzine), strong alkaline, or strong acids because they will damage the external finish. How to Mount the Timer on Mounting Usage Precautions Track Install a switch or circuit breaker that allows the operator to immediately turn OFF the power, and label it to clearly indicate its Mounting function. First hook portion A of the timer to the mounting track, then press the Be sure to wire the terminals correctly. timer in direction B. Do not install input lines in the same duct or conduit as power supply or other high-voltage lines. Doing so may result in Dismounting malfunction due to noise. Separate the input lines from high- Pull out portion C with a round-blade screwdriver and remove the voltage lines. timer from the mounting track. Internal elements may be destroyed if a voltage outside the rated voltage is applied. Maintain voltage fluctuations in the power supply within the specified range. A Use a switch, relay, or other contact so that the rated power supply voltage will be reached within 0.1 s. If the power supply voltage is not reached quickly enough, the H2C may malfunction or outputs may be unstable. Leaving the H2C with outputs ON at a high temperature for a long time may hasten the degradation of internal parts (such as C electrolytic capacitors). Therefore, use the H2C in combination with B relays and avoid leaving the H2C for more than 1 month with an output turned ON. Electrical Set The motor and clutch do not need to be reset simultaneously. X2/b T/a X1/a X1/a Use the voltage applied to the clutch for resetting with the H2C-@R. Do not allow power to be continuously applied to the motor and X Auxiliary relay clutch for extended periods of time. T X1 X2 (e.g., MY Relay) 10 Motor Timer H2C Discontinued Others Do not turn the operation time setting knob beyond the range of the scale. To achieve higher accuracy in setting, measure the operation time while turning the operation time setting knob. The deviation and setting error for the operation time shows the percent of FS. The absolute value of the deviation and setting error will not change even if the set time is changed. The time specifications should therefore be selected to use the operation time as close to FS as possible. At high temperatures, the operation voltage will be 90% or less if voltage is applied continuously after timeout. Be sure to keep the voltage within the allowable voltage fluctuation range. Precautions for EN61812-1 The H2C (except for H2C-F@) as a built-in timer conforms to EN61812-1, provided that the following conditions are satisfied. Handling Before dismounting the H2C from the Socket, make sure that no voltage is imposed on any terminal of the H2C. Applicable Sockets: P2CF-@@, P2CF-@@-E, PF085A, PL@@. Wiring Basic insulation is ensured between the motor circuit, clutch circuit, and control output circuit. (However, the H2C-8 motor circuit and clutch circuit use the same input.) Basic insulation is also ensured between the output circuits of models with instantaneous output. Basic insulation: Overvoltage category III, pollution degree 1 (See note.) Operating parts: Reinforced insulation (double insulation) (with a clearance of 5.5 mm and a creepage distance of 5.5 mm at 240 VAC) Output parts: Basic insulation (with a clearance of 3.0 mm and a creepage distance of 3.0 mm at 240 VAC) Note: Overvoltage category II, pollution degree 1 if the Timer is mounted to the PL11 Socket. Motor Timer H2C 11 Discontinued Warranty and Application Considerations Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. L007-E1-10 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company Industrial Devices and Components Division H.Q. Industrial Control Components Department Shiokoji Horikawa, Shimogyo-ku, Printed in Japan Kyoto, 600-8530 Japan Tel: (81)75-344-7119/Fax: (81)75-344-7149 0804-0.5C (0696) (M) 12 Discontinued
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the Y92H-2?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods