POWER PARTNERS PDAM500-14C
Specifications
Manufacturer
Power Partners
Manufacturers Part #
PDAM500-14C
Industry Aliases
PDAM500-14C
Series
PDAM500
Factory Pack Quantity
1
Application
General Purpose
Connection Type
Terminal
Cooling Method
Air-Cooled
Dimensions
5.50 x 3.25 x 2.48"
Efficiency
90.0%
Environmental Conditions
General Purpose
Industry
Industrial, Medical
Input Type
AC - Class I
Input Voltage Nominal
100-240 VAC
Isolation
4000 VAC
Mechanical Style
Open / Enclosed Frame
Mounting
Chassis Mount
Number of Outputs
1
Operating Temperature
-40 to +70°C (see derating)
Output Amps 1
20.8 A
Output Voltage V1 Nominal
24 VDC
Package Type
Enclosed with Fan
PFC
Yes
Power
500 W
Protection Level
2xMOPP
Standard Packaging Size
3 x 5
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
PDAM500 Series 500W Power Supply • UL / IEC / EN 60601 3.1 Edition & UL / IEC / EN 60950 AM2 Safety Approvals • High power density: 500W in 3” x 5” footprint • Open Frame or Enclosed Versions Available • Remote ON/OFF Function • Built-in 12V/0.3A Auxiliary Output • Standby 5V @ 1A with Fan, @ 0.6A without Fan • High Efficiency up to 92% • P.F.C. Function >0.95 Environmental & Operating Input Input Voltage: 90-264 VAC or 120-370 VDC Operating Temperature: -40ºC to +70ºC (with derating) Input Frequency: 47-63 Hz Storage Temperature: -40ºC to +85ºC Input Current (RMS): <6.0A @ 115 VAC; <3.0A @ 230 VAC Humidity: 95% RH Power Factor: >0.95 @ full load (230 VAC) Operating Altitude <5000m for medical use Inrush Current (<2ms): <35A @ 115 VAC; <70A @ 230 VAC MTBF: >160K hours per MIL-HDBK-217F at full Earth Leakage Current: <100 uA max. load and 25ºC ambient Compliance Safety Approvals: nd Output USA/Canada: UL60601-1 3.1 Ed, UL/cUL60950-1 2 Amdt. Europe: IEC/EN60601-1 3.1 Ed, TUV EN60950-1 Total Output: 500W max. See table for details. nd CB Report 2 Amdt. Output Voltage: See table. Isoluation: 4000VAC input to output 2x MOPP Hold Up Time: 8ms typical at 115VAC nominal line. (Note 4) 1500VAC input to ground 1x MOPP 1500VAC output to ground 1x MOPP Efficiency: Up to 92%. See table for details. EMC (IEC50501-1-2:2014): FCC Class B Radiated & Conducted EN55011/55022 Class B Radiated & Minimum Load: 0% Conducted Harmonic Currents: IEC 61000-3-2 Voltage Flicker: IEC 61000-3-3 Electrostatic Discharge: IEC 61000-4-2: 15kV air, 8kV contact Radiated Immunity: IEC 61000-4-3: 10V/m EFT/Burst: IEC 61000-4-4: +/-2kV Protection Surge Immunity: IEC 61000-4-5: 2005 1kV diff, 2kV com Conducted Immunity: IEC 61000-4-6: 10Vms Overvoltage: 110-132%, Auto Recovery Magnetic Field: IEC 61000-4-8: 30A/m Dips / Interruptions: IEC 61000-4-11: 30% reduction for Overcurrent: 145-170%, Auto Recovery 500ms, 100% reduction for 10 ms. Short Circuit: Auto Recovery General Dimensions: 3.0”W x 5.03”L x 1.38”H Weight: 450 g Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749 Your Partners in Power……... Tel: (978)567-9600 | Fax: (978)567-9601 Specifications subject to change. Website: www.powerpartners-inc.com PDAM500: March 2, 2017 Medical AC/DC Power PDAM500 Series 500W Power Supply Models and Ratings Output Max Load Max Load 30CFM Output Ripple & Efficiency Fan 1 +5VSB Model 2 7 6 Output Voltage Convection Forced Air Regulation Noise (230 VAC) Output PDAM500-12A 12V 20A 41.5A +/-1.2% 160mV 90.5% 12V/0.3A 5V/1A PDAM500-13A 15V 14.66A 33.3A +/-1.0% 160mV 90.5% 12V/0.3A 5V/1A PDAM500-14A 24V 10A 20.8A +/-1.0% 240mV 92% 12V/0.3A 5V/1A PDAM500-18A 48V 5A 10.41A +/-1.0% 480mV 93% 12V/0.3A 5V/1A Note: 1. All models are available in an enclosed version (e.g. PDAM500-12A would be PDAM500-12C) 2. Listed values are taken at 230VAC. At 115VAC, 19.16A, 9.58A, and 4.8A for the models listed as shown. 3. Recommended to add Varistor 14S471K at L/N input side in parallel. 4. Hold-up Time measured at 90% Vout 5. Main Vout >3% Load, 12V (Aux) / 0.3A. 6. Measured at 20MHz bandwidth with a 47uF electrolytic capacitor and 0.1uF ceramic capacitor in parallel at the output connector. 7. With convection cooling, 0.6A Block Diagram Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749 Your Partners in Power……... Tel: (978)567-9600 | Fax: (978)567-9601 Specifications subject to change. Website: www.powerpartners-inc.com PDAM500: March 2, 2017 Medical AC/DC Power PDAM500 Series 500W Power Supply Mechanical Outline (Open Frame) PIN # Signal 1 FG 2 AC IN (N) 3 AC IN (L) 4-6 +DC OUT 7-9 -DC OUT Connector Pin (FAN) PIN # Signal F1 +12V F2 GND Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749 Your Partners in Power……... Tel: (978)567-9600 | Fax: (978)567-9601 Specifications subject to change. Website: www.powerpartners-inc.com PDAM500: March 2, 2017 Medical AC/DC Power PDAM500 Series 500W Power Supply Mechanical Outline (Enclosed) Connector Pin (CN1) PIN # Signal C1 -5VSB C2 +5VSB C3 GND C4 DC OK C5 -RC C6 +RC C7 -S C8 +S Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749 Your Partners in Power……... Tel: (978)567-9600 | Fax: (978)567-9601 Specifications subject to change. Website: www.powerpartners-inc.com PDAM500: March 2, 2017 Medical AC/DC Power PDAM500 Series 500W Power Supply Function Description of CN1 Pin No. Function Description C1 -5VSB This pin connects to the negative terminal (-V). Return for DC-OK and –RC signal out- put. C2 +5VSB Stand by voltage output ground 3.7~6V, referenced to pin C8 (+5VSB). The maximum load current is 0.6A. C3 GND This pin connects to the negative terminal (-V). Return for DC-OK and –RC signal out- put. C4 DC OK DC-OK signal is a DC output, referenced to pin C6 (DC-OK GND). C5 -RC This pin connects to the negative terminal (-V). Return for DC-OK and –RC signal out- put. C6 +RC Turns the output on and off by electrical or dry contact between pin C4 (-RC), Short: Power OFF, Open: Power ON. C7 -S Negative sensing. The –S Signal should be connected to the negative terminal of the load. The –S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.3V. C8 +S Positive sensing. The +S Signal should be connected to the negative terminal of the load. The +S and –S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.3V. Function Manual & Application 1. DC-OK Signal Between DC-OK and Output GND Status 3.7~6V ON 0~1V OFF 2. Remote Control The unit can be turned ON/OFF by using the “Remote Control” function. Between +RC and Output -RC Status SW ON (Short) OFF SW OFF (Open) ON Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749 Your Partners in Power……... Tel: (978)567-9600 | Fax: (978)567-9601 Specifications subject to change. Website: www.powerpartners-inc.com PDAM500: March 2, 2017 Medical AC/DC Power PDAM500 Series 500W Power Supply Power Derating 500W with 25 CFM FAN Power Derating Curve 240W Air Convection at 230 VAC 230W Air Convection at 115 VAC (Operating Temperature °C) Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749 Your Partners in Power……... Tel: (978)567-9600 | Fax: (978)567-9601 Specifications subject to change. Website: www.powerpartners-inc.com PDAM500: March 2, 2017 Medical AC/DC Power PDAM500 Series 500W Power Supply Efficiency Versus Load PDAM500-12 VIN VS Efficiency LOAD VS Efficiency Input Voltage (V) 90 115 180 230 264 Load (%) 10 20 30 40 50 Efficiency (%) 85.78 86.58 89.21 90.01 90.34 115V (%) 86.67 89.20 89.80 90.06 89.87 230V (%) 88.19 90.82 91.00 91.71 91.86 Load (%) 60 70 80 90 100 115V (%) 89.30 88.77 88.18 87.27 86.58 230V (%) 91.77 91.40 90.79 90.44 90.01 PDAM500-14 VIN VS Efficiency LOAD VS Efficiency Input Voltage (V) 90 115 180 230 264 Load (%) 10 20 30 40 50 Efficiency (%) 87.99 88.84 91.29 92.13 92.48 115V (%) 86.38 90.14 91.42 91.48 91.52 230V (%) 87.90 91.79 93.12 93.40 93.58 Load (%) 60 70 80 90 100 115V (%) 91.12 90.61 90.20 89.35 88.84 230V (%) 93.39 93.27 92.72 92.47 92.13 Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749 Your Partners in Power……... Tel: (978)567-9600 | Fax: (978)567-9601 Specifications subject to change. Website: www.powerpartners-inc.com PDAM500: March 2, 2017 Medical AC/DC Power PDAM500 Series 500W Power Supply Efficiency Versus Load PDAM500-18 VIN VS Efficiency LOAD VS Efficiency Input Voltage (V) 90 115 180 230 264 Load (%) 10 20 30 40 50 Efficiency (%) 87.36 89.18 92.88 93.89 94.33 115V (%) 86.60 90.27 91.54 91.83 91.84 230V (%) 89.45 93.31 94.10 94.45 94.66 Load (%) 60 70 80 90 100 115V (%) 91.67 91.33 90.72 90.14 89.47 230V (%) 94.65 94.47 94.22 94.29 93.96 Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749 Your Partners in Power……... Tel: (978)567-9600 | Fax: (978)567-9601 Specifications subject to change. Website: www.powerpartners-inc.com PDAM500: March 2, 2017 Medical AC/DC Power
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the PDAM500-14C?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods