Power Partners
Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.
Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.
Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.
Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.
Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.
Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.
After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.
Electronics Finder is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.
Do you need a PEAD50-10-B2? We can help you find it at a competitive price!
Manufacturer | Power Partners |
---|---|
Manufacturers Part # | PEAD50-10-B2 |
Series | PEAD50 |
Factory Pack Quantity | 1 |
Download "PEAD50.pdf" (828 KiB)
Class I and Class II Versions Efficiency Level VI <210mW No Load Power Consumption LED on Indicator Overload Protection Short Circuit Protection No Load Operation 100% Burn-In/Hi-Pot Testing RoHS Compliant *Note: Country specific approvals may not apply to all models shown. Please consult factory. Electrical Specifications Input Environmental & Operating Operating Temperature 0ºC to 60ºC (Derate output power linearly from 100% at 40°C to 50% at 60°C) Input Voltage 90-264VAC Storage Temperature -20ºC to +85ºC Input Frequency 47-63 Hz Humidity 10% - 90% non-condensing Input Current 1.5A max at 115VAC Altitude <5000m operational and storage 0.75A max at 230VAC MTBF: >100,000 hours per MIL-HDBK-217F at full Inrush Current <100A peak at 240VAC, cold start, 25ºC load and 25ºC ambient Compliance Safety Approvals USA UL60950-1 Canada cUL60950-1 Output Europe TUV EN60950-1/A12: 2011 Japan (PSE) J60950-1(H22) J55022(H22) Total Output See Models and Ratings Chart CB Report Output Voltage See Models and Ratings Chart EMC: FCC Class B Radiated & Conducted Hold Up Time >8.3mS at full load and 115/230VAC line CISPR22 Class B Radiated & Conducted Average Active efficiency Meets DOE level VI requirements EN55022 Class B Radiated & Conducted No Load Power Consumption <210mW EN55024: 2010 Turn on Delay <3 seconds Harmonic Currents IEC 61000-3-2: Voltage Flicker IEC 61000-3-3 Electrostatic Discharge IEC 61000-4-2: 8kV Air, 6kV contact Radiated Immunity IEC 61000-4-3: 3V/m EFT/Burst IEC 61000-4-4: +/-1kV Surge Immunity IEC 61000-4-5: 2005 1kV diff, 2kV com Conducted Immunity IEC 61000-4-6: 3Vrms Magnetic Field IEC 61000-4-8: 1A/m Dips / Interruptions IEC 61000-4-11: 30% reduction for 500ms, >95% reduction for 10ms. Protection Overvoltage 150% Max. of nominal. Cycle AC power to reset after fault is removed Overload 110%-160% of maximum output current. General Auto recovery Short Circuit Hiccup mode. Auto recovery Dimensions 4.45”(113mm)L x 1.93”(49mm)W x 1.37”(35mm)H Ingress IP22 Compliant IEC60320 C14, C6, C8, C18 AC Input Receptacle 2.5x5.5mm barrel connector DC output Plug Weight 1lb Your Partners in Power……... Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749 Tel: (978)567-9600 | Fax: (978)567-9601 Specifications subject to change. Website: www.powerpartners-inc.com PEAD50: April 3, 2018 Desktop AC/DC Power Models and Ratings Chart Model* Voltage Max. Total Load Line Ripple & Efficiency Current Power Regulation Regulation Noise (P-P) Level PEAD50-10-B2 5V 6.00A 30W +/-5% +/-3% 100mV VI PEAD50-11-B2 9V 3.33A 30W +/-5% +/-3% 100mV VI PEAD50-12-B2 12V 4.17A 50W +/-5% +/-3% 250mV VI PEAD50-13-B2 15V 3.33A 50W +/-5% +/-3% 250mV VI PEAD50-13-1-B2 18V 2.63A 47.3W +/-5% +/-3% 350mV VI PEAD50-13-2-B2 19V 2.63A 50W +/-5% +/-3% 350mV VI PEAD50-14-B2 24V 2.08A 50W +/-5% +/-3% 350mV VI PEAD50-17-B2 36V 1.38A 50W +/-5% +/-3% 500mV VI PEAD50-18-B2 1.04A 50W +/-5% +/-3% 720mV VI 48V *C14 standard input receptacle For C8 input receptacle, model numbers are PEAD50SF. For example, PEAD50SF-12-B2 For C6 input receptacle, model numbers are PEAD50S. For example, PEAD50S-12-B2 For C18 input receptacle, model numbers are PEAD50F. For example, PEAD50F-12-B2 Mechanical Outline Output Return Connected to Ground on Class I Models. Your Partners in Power……... Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749 Tel: (978)567-9600 | Fax: (978)567-9601 Website: www.powerpartners-inc.com Specifications subject to change. PEAD50: April 3, 2018 Desktop AC/DC Power