Electronics Finder chervon right Manufacturers chervon right S chervon right SCHURTER chervon right 4430.2187
About product Specifications Datasheet FAQ

SCHURTER 4430.2187

Image of SCHURTER 4430.2187

Description

Cover For Two Pole Rocker Actuated
4430.2187

Part Number

4430.2187

Price

Request Quote

Manufacturer

SCHURTER

Lead Time

Request Quote

Category

Circuit Protection »  Circuit Breaker Accessories

Specifications

Manufacturer

Schurter

Manufacturers Part #

4430.2187

Industry Aliases

TA45-AZM03-752, 4430.2187

Sub-Category

Circuit Breaker Accessories

Factory Pack Quantity

1

Datasheet

pdf file

typ_TA45-2R.pdf

596 KiB

Extracted Text

Thermal (T- and TA-Line) TA45-2R https://www.schurter.com /PG17_20 Circuit Breaker for Equipment thermal, 2 pole, Rocker actuation See below: Approvals and Compliances Description Applications - Thermal circuit breaker - Power tools - 1 or 2 pole thermal overload protection - Industrial appliances - Positively trip-free release - Power supplies - High configurability Weblinks - Rocker non-illuminated or illuminated pdf datasheet, html-datasheet, General Product Information, Distributor- - Snap-in version Stock-Check, Detailed request for product, Product News - Quick connect terminal 6.3 x 0.8 mm or screw clamp terminal M3.5 x 6 mm (lineside P1, P2) Technical Data Rated Voltage AC 240 V Overload AC: min. 40 trips @ 6 x Ir Rated Voltage DC 60 V ␣ DC: min. 40 trips Rated current range AC 0.05 - 20 A @ 4 x Ir Conditional short circuit ca- IEC: Inc, PC1, AC 240 V: 1 kA Ambient temperature -10 °C to 55 °C pacity Vibration Resistance ± 0.75 mm @ 5 - 60 Hz Degree of Protection from front side IP 40 acc. to IEC 60529 acc. to IEC 60068-2-6, test Fc Dielectric Strength 4 kVAC 10 G @ 60 - 500 Hz Insulation Resistance 500 VDC > 100 MΩ acc. to IEC 60068-2-6, test Fc Lifetime mechanical: 50'000 switching cycles Shock Resistance 30 G / 18 ms ␣ AC: 1 x Ir: acc. to IEC 60068-2-27, test Ea 50'000 switching cycles Tripping Type Thermal ␣ DC: 1 x Ir: Actuation Type Rocker 50'000 switching cycles Weight 30 - 35 g Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: TA45 Approval Logo Certificates Certification Body Description VDE Approvals VDE VDE Certificate Number: 40019880 UL Approvals UL UL File Number: E71572 CQC Approvals CQC CCC Certificate Number: 2013010307660082 Circuit Breakers 1 Thermal (T- and TA-Line) TA45-2R https://www.schurter.com /PG17_20 Product standards Product standards that are referenced Organization Design Standard Description Designed according to IEC 60934 Circuit-breakers for equipment (CBE) Designed according to UL 1077 Standard for Supplementary Protectors for Use in Electrical Equipment Designed according to CSA C22.2 No. 235 Supplementary Protectors Designed according to GB 17701 Circuit-breaker for equipment Application standards Application standards where the product can be used Organization Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technologyequipment. Compliances The product complies with following Guide Lines Identification Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG EU Directive RoHS 2011/65/EU China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. Dimension [mm] Quick connect terminal Screw clamp terminal 25 16 48 10.8 23.7 44.1 P1 a 3 5 P1 a 3 5 B) 10.8 8.4 5.3 26.7 10.8 A) 21.5 A) Quick connect terminal, IEC 61210, A6.3-0.8 mm B) Screw type M3, 5x6 (Philips Form H), maximum torque 1 Nm Accessories / factory mounted AZM01 / Collar with cover, IP 54 AZM02 / Raised collar with cover, narrow, IP 54 AZM03 / Raised collar, IP 40 33.6 56.6 27.5 50.5 33.6 48 19.2 56.5 27.5 50.5 19.2 2 Circuit Breakers 3.5 17.6 8.1 12.5 12.5 10.6 34 43.7 17.6 15.3 26.7 43.7 Thermal (T- and TA-Line) TA45-2R https://www.schurter.com /PG17_20 AZM10 / Collar with cover, narrow, IP 54 AZM11 / Partially raised collar with cover, narrow, IP 54 AZM12 / Partially raised collar without cover, narrow, IP 40 50 27 37.2 19.2 50 48 AZM13 / Raised collar narrow, IP40 AZM14 / Raised collar with cover narrow, IP 54 27 50 27 50 19.2 Cut-out and pin-out Cut-out snap-in type Pin-out a b P1 P2 1.0 44,5...45,0 1.5 44,5...45,0 U-Relais a b 2.0 44,7...45,2 2.5 44,7...45,2 3.0 44,8...45,3 4.0 44,9...45,4 c 5.0 45,0...45,5 b 4 3 1) 6 5 2) 1) Assemble 2) edge must be sharp Circuit Breakers 3 14 +0.2 21.7 –0.0 a (1.0 – 5.0) 8.8 17.3 43.8 10.6 33.2 17.3 17.3 14 14 43.8 10.6 33.2 Thermal (T- and TA-Line) TA45-2R https://www.schurter.com /PG17_20 Diagrams 1 pole thermal overload protection 1 pole thermal overload protection, Shunt terminal P2 P1 P2 P1 3 3 6 6 5 2 pole thermal overload protection 2 pole thermal overload protection, Shunt terminal P2 P1 P2 P1 4 3 4 3 6 5 Effect of ambient temperature The units are calibrated for an ambient temperature of +23°C. To determine the rated cur- rent for a lower or higher ambient temperature, use a correction factor (typical value) from the table below: Ambient temperature [°C] Correction factor -10 0.89 -5 0.91 0 0.92 +23 1.00 +30 1.03 +40 1.08 +55 1.16 Example: Rated current = 5 A; Environmental temperature = 40 °C; --> Correction factor = 1.08; Resulting current = 5.5 A --> Fount to next higher rated current: 6 A 4 Circuit Breakers Thermal (T- and TA-Line) TA45-2R https://www.schurter.com /PG17_20 Time-Current-Curves [ min ] [ sec ] [ min ] [ sec ] 10'000 10'000 Type TA45 Type TA45 Rated current I <3 A Rated current 3 A > I <18 A n n 60 60 1 pole protected 1 pole protected 2`000 2`000 2 pole protected 2 pole protected 30 30 20 20 Ambient temp. +23ºC Ambient temp. +23ºC 1`000 1`000 10 10 500 500 5 5 200 200 100 100 1 1 50 50 20 20 10 10 5 5 2 2 1 1 0,5 0,5 0,3 0,3 0,2 0,2 0,1 0,1 1,05 1,32 2 3 4 5 8 10 1,05 1,32 2 3 4 5 8 10 Multiple of Rated Current In Multiple of Rated Current In Reference Temperature +23° Reference Temperature +23° [ min ] [ sec ] 10'000 Type TA45 Rated current I > 18 A n 60 1 pole protected 2`000 2 pole protected 30 20 Ambient temp. +23ºC 1`000 10 500 5 200 100 1 50 20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,32 2 3 4 5 8 10 Multiple of Rated Current In Reference Temperature +23° Config. Code TA45|-|AK2|W|F|120|A2|-|AZM11| The characters are placeholders for the correspondingly keys of selections from the key tables. TA45|-| AK2 |W|F|120|A2|-|AZM11| = Basic function Circuit Breakers 5 Time in Seconds Time in Seconds Time in Seconds Thermal (T- and TA-Line) TA45-2R https://www.schurter.com /PG17_20 Basic function Configuration Basic function Configuration key key 2-pole, rocker, 1pole overload protection, flat connection, illuminated 220 A12 2-pole, rocker, 2pole overload protection, screw connection, illuminated 4 A89 V...240 V V...7 V 2-pole, rocker, 1pole overload protection, flat connection, illuminated 110 A14 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, A92 V...120 V illuminated 220 V...240 V 2-pole, rocker, 1pole overload protection, flat connection, illuminated 20 A17 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, A94 V...26 V illuminated 110 V...120 V 2-pole, rocker, 1pole overload protection, flat connection, illuminated 10 A18 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, A97 V...13 V illuminated 20 V...26 V 2-pole, rocker, 1pole overload protection, flat connection, illuminated 4 A19 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, A98 V...7 V illuminated 10 V...13 V 2-pole, rocker, 1pole overload protection, shunt terminal, flat connection, A22 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, A99 illuminated 220 V...240 V illuminated 4 V...7 V 2-pole, rocker, 1pole overload protection, shunt terminal, flat connection, A24 2-pole, rocker, 2pole overload protection, flat connection, without illumi- ABD illuminated 110 V...120 V nation 2-pole, rocker, 1pole overload protection, shunt terminal, flat connection, A27 2-pole, rocker, 1pole overload protection, shunt terminal, flat connection, ABF illuminated 20 V...26 V without illumination 2-pole, rocker, 1pole overload protection, shunt terminal, flat connection, A28 2-pole, rocker, 2pole overload protection, shunt terminal, flat connection, ABG illuminated 10 V...13 V without illumination 2-pole, rocker, 1pole overload protection, shunt terminal, flat connection, A29 2-pole, rocker, 1pole overload protection, flat connection, without illumi- ABT illuminated 4 V...7 V nation 2-pole, rocker, 2pole overload protection, flat connection, illuminated 220 A32 2-pole, rocker, 2pole overload protection, flat connection, momentary AED V...240 V switch, without illumination 2-pole, rocker, 2pole overload protection, flat connection, illuminated 110 A34 2-pole, rocker, 1pole overload protection, shunt terminal, flat connection, AEF V...120 V momentary switch, without illumination 2-pole, rocker, 2pole overload protection, flat connection, illuminated 20 A37 2-pole, rocker, 2pole overload protection, shunt terminal, flat connection, AEG V...26 V momentary switch, without illumination 2-pole, rocker, 2pole overload protection, flat connection, illuminated 10 A38 2-pole, rocker, 1pole overload protection, flat connection, momentary AET V...13 V switch, without illumination 2-pole, rocker, 2pole overload protection, flat connection, illuminated 4 A39 2-pole, rocker, 2pole overload protection, screw connection, without illu- AHD V...7 V mination 2-pole, rocker, 2pole overload protection, shunt terminal, flat connection, A42 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, AHF illuminated 220 V...240 V without illumination 2-pole, rocker, 2pole overload protection, shunt terminal, flat connection, A44 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, AHG illuminated 110 V...120 V without illumination 2-pole, rocker, 2pole overload protection, shunt terminal, flat connection, A47 2-pole, rocker, 1pole overload protection, screw connection, without illu- AHT illuminated 20 V...26 V mination 2-pole, rocker, 2pole overload protection, shunt terminal, flat connection, A48 2-pole, rocker, 2pole overload protection, screw connection, momentary AJD illuminated 10 V...13 V switch, without illumination 2-pole, rocker, 2pole overload protection, shunt terminal, flat connection, A49 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, AJF illuminated 4 V...7 V momentary switch, without illumination 2-pole, rocker, 1pole overload protection, screw connection, illuminated A62 2-pole, rocker, 2pole overload protection, shunt terminal, screw connection, AJG 220 V...240 V momentary switch, without illumination 2-pole, rocker, 1pole overload protection, screw connection, illuminated A64 2-pole, rocker, 1pole overload protection, screw connection, momentary AJT 110 V...120 V switch, without illumination 2-pole, rocker, 1pole overload protection, screw connection, illuminated A67 20 V...26 V TA45|-|AK2| W |F|120|A2|-|AZM11| = Actuator colour 2-pole, rocker, 1pole overload protection, screw connection, illuminated A68 10 V...13 V Actuator colour Configuration 2-pole, rocker, 1pole overload protection, screw connection, illuminated 4 A69 key V...7 V Clear transparent 1 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, A72 illuminated 220 V...240 V Red transparent 3 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, A74 Green transparent 4 illuminated 110 V...120 V Orange transparent 6 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, A77 Black B illuminated 20 V...26 V 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, A78 Green G illuminated 10 V...13 V Red R 2-pole, rocker, 1pole overload protection, shunt terminal, screw connection, A79 White W illuminated 4 V...7 V Orange X 2-pole, rocker, 2pole overload protection, screw connection, illuminated A82 220 V...240 V Yellow Y 2-pole, rocker, 2pole overload protection, screw connection, illuminated A84 110 V...120 V TA45|-|AK2|W| F |120|A2|-|AZM11| = Legend 2-pole, rocker, 2pole overload protection, screw connection, illuminated A87 20 V...26 V 2-pole, rocker, 2pole overload protection, screw connection, illuminated A88 10 V...13 V 6 Circuit Breakers Thermal (T- and TA-Line) TA45-2R https://www.schurter.com /PG17_20 Legend Configuration Rated current Configuration key key 2.2 A J22 embossed F 2.3 A J23 2.5 A J25 2.8 A J28 white printed H 3.0 A 030 3.5 A 035 black printed K 4.0 A 040 4.5 A 045 white printed L 5.0 A 050 6.0 A 060 6.5 A 065 black printed M 7.0 A 070 7.5 A 075 I0 white printed P 8.0 A 080 9.0 A 090 I0 black printed R 10.0 A 100 11.0 A 110 12.0 A 120 white printed S 13.0 A 130 14.0 A 140 black printed T 15.0 A 150 16.0 A 160 17.0 A 170 TA45|-|AK2|W|F| 120 |A2|-|AZM11| = Rated current 18.0 A 180 19.0 A 190 Rated current Configuration key 20.0 A 200 0.05 A Z05 Other rated currents on request 0.1 A J01 0.2 A J02 0.3 A J03 TA45|-|AK2|W|F|120| A2 |-|AZM11| = Release / lock-out latch 0.4 A J04 0.5 A J05 Release / lock-out latch Configuration key 0.6 A J06 whithout release / lock-out latch C0 0.7 A J07 0.8 A J08 0.9 A J09 TA45|-|AK2|W|F|120|A2|-| AZM11 | = Accessories 1.0 A J10 Factory mounted accessories Configuration 1.1 A J11 key 1.2 A J12 Without cover 1.3 A J13 Collar with cover, IP54 AZM01 1.4 A J14 Raised collar with cover, IP54 AZM02 1.5 A J15 Raised collar, IP40 AZM03 1.6 A J16 Raised collar with cover narrow, IP54 AZM10 1.7 A J17 Partially raised collar with cover, narrow, IP54 AZM11 1.8 A J18 Partially raised collarwithout cover, narrow, IP40 AZM12 1.9 A J19 Raised collar narrow, IP40 AZM13 2.0 A J20 Raised collar with cover narrow, IP54 AZM14 2.1 A J21 For subsequent fitting accessories see: Other rated currents on request http://www.schurter.com/pdf/english/typ_TA45-ACC.pdf Circuit Breakers 7 ON ON I I ON ON I I I 0 0 0 0 OFF OFF 0 OFF OFF Thermal (T- and TA-Line) TA45-2R https://www.schurter.com /PG17_20 Variants Thermal Addition connection Illumination Actuator colour Legend Rated current Accessories Config. Code Order Number overload pro- type tection 1-pole Quick connect without illu- White embossed 10.0 A Without cover TA45-ABTWF100C0 4430.0022 █ terminal mination 2-pole Quick connect without illu- Black white printed 15.0 A Without cover TA45-ABDBL150C0 4430.1089 █ terminal mination 2-pole Quick connect without illu- Black white printed 15.0 A Without cover TA45-ABDBS150C0 4430.1328 █ terminal mination █ Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER 1 Pcs Packaging Unit Accessories Description TA45-ACC Accessories to TA45 The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed 8 Circuit Breakers to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. 19.01.2018

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the 4430.2187?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Cover For Circuit Breaker With Polymer Material 4400.0405

product

Protection Cover For IP 65 Circuit Breakers 4404.0039

product

Cover For Two Pole Rocker Actuated 4430.0582

product

Cover For Two Pole Rocker Actuated 4430.1172

product

Cover For 2 Pole Rocker Actuated For All Basic-Types Of TA45 With Rocker Actuated 4430.1360

product

Cover For Two Pole Rocker Actuated 4430.3496