Details

Part Number CA1000-XXXXXX
Manufacturer TDK-LAMBDA
Category Circuit Protection »  AC-DC Power Supply
Price Request Quote
Lead Time Request Quote

Description

AC-DC, MODULAR, INPUT 115-230VAC, OUTPUT - MODEL DEPENDENT, 1000W

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Electronics Finder is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a CA1000-XXXXXX? We can help you find it at a competitive price!

Specifications

Manufacturer TDK-Lambda
Manufacturers Part # CA1000-XXXXXX
Industry Aliases CA1000-XXXXXX
Brand TDK-Lambda
Series Alpha
Factory Pack Quantity 1
Cooling Method Air-Cooled
Efficiency 75%
IP Rating IP10
Isolation 4300 VDC
Mechanical Style Modular
Mounting Chassis
Operating Temperature 0 to + 70°C
Package Type Enclosed
Power 1000 W
Subcategory AC-DC Power Supply

Datasheet

Download "alpha400_1500_ds.pdf" (236 KiB)

Extracted Text

+ Power INNOVATION • SOLUTIONS • SUPPORT • RELIABILITY • Up to 1500W output • Up to 16 outputs • Voltages up to 48V, Current up to 300 Amps • Fast-on output connection • Worldwide approvals & CB report • Medical Approval Option • 3 Year Warranty Key Market Segments & Applications Instrumentation Broadcast Alpha Medical ATE Automation Industrial Computing 400, 600, 1000 & 1500 Watts Modular Security Lifesciences/Laboratory Network Servers and Routers INPUT Alpha 400 90 - 264Vac Alpha 600 90 - 264Vac, 160 - 358Vdc Input Voltage Alpha 1000 85 - 264Vac, 120 - 360Vdc Alpha 1500 85 - 264Vac (1000W below 150Vac input) Input Frequency 47 - 63Hz (440Hz with reduced PFC - consult factory) Inrush Current <50A at 25°C and 264Vac (cold start) 250Vac HBC Fast Acting (not user accessible) 10A for 400W Input Fuse 12A for 600W 20A for 1000W and 1500W Leakage Current 1.1mA max at 264Vac & 63Hz Lower Leakage Option see configuring guide Power Factor 0.99 typical OUTPUT Voltage / Current See module output table Turn on Delay 1.5s max at 90Vac (150Vac for Alpha 1500W) & 100% rated output power Rise Time <50ms to 90% of voltage, monotonic rise above 10% Turn on Overshoot <5% or 250mV Load type dependant, no overshoot with resistive load Efficiency 75% typical at 230Vac & 100% rated power, config dependent at 90Vac & 100% rated output power Hold up 15ms min 13ms for 1000W, 8ms for 1500W and at 207Vac for 1500W Ripple & Noise <2% (or 100mV if greater) Pk- Pk, using EIAJ test method & 20MHz bandwidth Voltage Accuracy <1% of set Voltage Remote Sense Yes Standard on single output modules Minimum Load No on any output Temperature Coefficient <0.02% of rated voltage per °C Load Regulation <0.5% or 25mV for 0-100% load change (with sense connected, <2% without) Line Regulation <0.5% for 90 - 264Vac input change (210-264Vac for 1500W) Cross Regulation <0.2% for 100% load change on any other output <10% of set voltage for 50% load change (above 25% load) Transient Response Recovery 500µs for recovery to 1% or 100mV of set voltage (1000µs for S module) Over Voltage Protection Standard for all outputs Over Current Protection Standard for all outputs Short Circuit Protection <150% of rated current, when output voltage <1% Over Temperature Protection Yes Shuts down all outputs. Cycle ac off / on to reset Note shutdown temp varies according to ambient, output power and input V ALPHA SERIES 1 Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 SAFETY APPROVALS Date Amendments Date Amendments IEC 60601-1a EN 60950-1 2001 1988 A1, A2 UL 60601-1a UL 60950-1 2003 2003 CSA 60601-1a CSA22.2 No 60950-1 2003 2003 IEC60950-1* 2001 CE Mark LV Directive 2006/95/EC (EN60950-1) * CB Certificate and report available on request a - Only for LL, RL and TL leakage variants. CA400 + CA1000 only PRODUCT, GENERIC & COLLATERAL STANDARDS Compliant to High Low Voltage Power Supply, EMC EN61204-3: 2001 Class A emissions for CA1000 / CA1500 Severity Immunity Medical Electrical Equipment, EMC EN61601-1-2: 2001 Compliant Class A emissions for CA1000 / CA1500 Immunity for residential, commercial and EN61000-6-1: 2001 Compliant light industrial environments Immunity for industrial environments EN61000-6-2: 2001 Compliant Emissions for residential, commercial and EN61000-6-3: 2001 Compliant CA1000 and CA1500 not compliant light industrial environments Emissions for industrial environments EN61000-6-4: 2001 Compliant EMISSIONS Class B (as per CISPR.22) See application note for details. Radiated Electric Field EN55022 Class A for Alpha 1000/1500 Only for ‘S’ type leakage versions Class B (as per CISPR.22) Only for ‘S’ type leakage versions. Conducted Emissions EN55022 Class A for Alpha 1000/1500 ‘M’ & ‘L’ types meet Class A Conducted Harmonics EN61000-3-2: 2001 Compliant to Class A Compliant - d only. Flicker EN61000-3-3: 1995 + A1:2001 max IMMUNITY Criteria Air discharge 15kV Electrostatic Discharge EN61000-4-2 Level 4 A Contact discharge 8kV Electromagnetic Field EN61000-4-3 Level 3 10V/m (tested to 12V/m) A Input 4kV Fast / Burst Transient EN61000-4-4 Level 4 Outputs 2kV, A Tested at 5kHz and 100kHz Line to Line (Differential) 1.1kV Surge Immunity EN61000-4-5 Level 3 A Line to Earth (Common Mode) 2.2kV Conducted RF Immunity EN61000-4-6 Level 3 10V (tested to 12V) A Power Frequency Magnetic Field EN61000-4-8 Level 4 30A Continuous A Voltage Dips, Variation, A EN61000-4-11 Class 3 B for 5s interruptions Interruptions Voltage Fluctuations EN61000-4-14 Class 3 For 100 to 240V nominal A ENVIRONMENT Temperature 0°C to 70°C operational, -40° to 85°C storage (max 12 months) Derating 50°C to 70°C derate each output by 2.5% per °C Low Temperature Start-up -20°C Humidity 5-95% RH non condensing Shock 3000 shocks, each of 10g (16ms) half sine Vibration 10 - 200Hz @ 1.5g Altitude 3,000 metres operational (15,000 metres non operational) Pollution Degree 2, Material group 3 IP Rating IP 10 ISOLATION Input to Output Reinforced 4.3 kV (dc) Output to Earth Operational 500 V (dc) Input to Earth Basic 2.3 kV (dc) Output to Output Operational 500 V (dc) ALPHA SERIES 2 Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 OUTPUT VOLTAGES (single output modules) (twin output modules) Adjustment Amps Slots Module V1 Adjustment Amps V2 Adjustment Amps Slots Module A 4.5 - 5.5 60 2 E 5 - 16 8 5 - 16 8 1 AA 4.5 - 6.5 60 2 EB 4.5 - 5.5 9 4.5 - 5.5 9 1 B 4.5 - 5.5 25 1 EQ 4.5 - 5.5 9 2.7 - 3.9 9 1 BB 4.5 - 6.5 25 1 H 18 - 32 5 18 - 32 5 1 16 C 5 - 16 1 P 18 - 29 5 5 - 16 8 1 a D 18 - 29 8 1 F 9 - 16 33 2 25 G 17.5 - 29 2 b 10 J 30 - 48 2 c K 18 - 29 15 2 L 1.8 - 3.2 25 1 M 5 - 16 8 1 5 N 18 - 32 1 d Q 2.7 - 3.9 25 1 R 2.7 - 3.9 60 2 S 2.5 - 5.7 85 2 T 1.8 - 3.2 60 2 a) 12A max above 12V U 10 - 21 16 1 b) 21A max above 24.5V W 4.5 - 5.5 15 1 c) Derate output current by 0.25A / V above 40V Z 4.5 - 5.5 25 1 d) 1A max above 29V Alpha Configuring Guide The extensive range of output modules and options make it possible to achieve many combinations of Volts and Amps. To achieve the optimum configuration, please contact our sales office. However you can also create your own configuration from this datasheet by using the guide below. Configuring from Datasheet 1 Calculate total output power to determine Alpha 400W, 600W, 1000W or 1500W and select converter, then select required Cooling and Leakage Current from the following table:- CA 400 QF LL 400 (5 slots) 600 (5 slots) Output Power empty Standard 1.1 mA 1000 (7 slots) ML 500µA 1500 (8 slots) Earth Leakage Current LL 240µA empty Forward air - Standard (at 264Vac, 63Hz) RL 110µA a QF Cooling Forward air - Quiet fan TL 50µA RAb Reverse air Notes: a) CA400/600 only. CA400 derates to 300W, CA600 derates to 475W b) Contact sales office for details 2 Select Output Modules and Options from the Output Voltages tables. Example - if you require 5.2V / 18A with output inhibit : - a) select B as closest match for voltage and current and prefix with voltage (e.g. 5.2B) b) add suffix for option (if required) ‘_PA’ for parallel/current share (for N+1 redundant applications) ‘_PP’ for parallel (increase current from one PSU) ‘_IN’ for inhibit ‘_RP’ for remote programming ‘_MF’ (only applicable on 1st module) for global inhibit, ac fail and 5V/50mA standby supply c) repeat for other outputs Ensure that the total width of all selected modules is within the slots for the chosen converter. For example:- CA600LL 5A 12/12E 24D which represents a four output 600W Alpha with Forward air, 240µA Earth Leakage, with:- Output 1 = 5V / 60A with remote sense Output 2 = 12V / 8A Output 3 = 12V / 8A Output 4 = 24V / 8A with remote sense 3 Contact TDK-Lambda to validate configuration and issue a part number. ALPHA SERIES 3 Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 4 1 1 slot, 2 output 1 slot, 1 output 2 slot, 1 output Option Connections 5 2 IN, PA, 6 3 PP, RP + + + Option - - - Pin IN option PA option PP option RP option MF option 1 n/c + Sense + Sense + Sense Inhibit (low) + 6 + 5 - 2 Module Good Module Good n/c - Sense 5V supply 4 Remote sense 3 + - 2 3 Inhibit Star point n/c Control 2 Power Fail - 1 4 n/c - Sense - Sense n/c 0V 5 - Power - Power n/c Control 1 Inhibit (high) 6 - Power Star point n/c n/c n/c Alpha 400 Alpha 600 ALPHA SERIES 4 Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 MF option Alpha 1000 Alpha 1500 ALPHA SERIES 5 Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 TDK-LAMBDA EMEA AUSTRIA TDK-LAMBDA GERMANY GmbH Telephone: +43 (0) 2256 655 84 Aredstraße 22 Facsimile: +43 (0) 2256 645 12 A-2544 Leobersdorf Web: www.lambda-austria.com FRANCE TDK-LAMBDA FRANCE SAS Telephone: +33 (0) 1 60 12 71 65 ZAC des Delaches, BP1077 - Gometz le Chatel Facsimile: +33 (0) 1 60 12 71 66 91940 Les Ulis Web: www.lambda-f.com GERMANY TDK-LAMBDA GERMANY GmbH Telephone: +49 (0) 78 41 666 0 Karl-Bold-Straße 40 Facsimile: +49 (0) 78 41 5000 D-77855 Achern Web: www.lambda-germany.com ISRAEL NEMIC LAMBDA LTD Telephone: +972 (0) 3 902 4333 Kibbutz Givat Facsimile: +972 (0) 3 902 4777 Hashlosha 48800 Web: www.nemic.co.il ITALY TDK-LAMBDA ITALY s.r.l. Telephone: +39 (0) 02 61 29 38 63 Via dei Lavoratori 128/130, Facsimile: +39 (0) 02 61 29 09 00 20092, Cinisello Balsamo (Mi) Web: www.lambda-italy.com SWEDEN TDK-LAMBDA SCANDINAVIA Telephone: +46 (0) 8 598 94 090 PO Box 546, Rallervägen 41 Facsimile: +46 (0) 8 540 66 096 SE-184 25. Åkersberga Web: www.lambda-scandinavia.com UK TDK-LAMBDA UK Telephone: +44 (0) 1271 856666 Kingsley Avenue Facsimile: +44 (0) 1271 864894 Ilfracombe Devon EX34 8ES Web: www.lambda-gb.com TDK-LAMBDA NORTH AMERICA visit http://us.tdk-lambda.com/ for a list of TDK-Lambda offices and distributors TDK-LAMBDA ASIA visit http://www.tdk-lambda.com/ for a list of TDK-Lambda offices and distributors LOCAL DISTRIBUTION ALPHA SERIES 6 Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08

Related Products

TDK-LAMBDA
AC-DC, MODULAR, INPUT 115-230VAC, OUTPUT - MODEL DEPENDENT, 600W
TDK-LAMBDA
1000 W, Single Output, 48 VDC@21 A AC-DC Power Supply
TDK-LAMBDA
504 W, Single Output, 48 VDC@10.5 A AC-DC Power Supply
TDK-LAMBDA
504 W, Single Output, 48 VDC@10.5 A AC-DC Power Supply
TDK-LAMBDA
AC-DC, MODULAR, INPUT 115-230VAC, OUTPUT - MODEL DEPENDENT, 250W
TDK-LAMBDA
AC-DC, MODULAR, INPUT 115-230VAC, OUTPUT - MODEL DEPENDENT, 250W

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Electronics Finder are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

Electronics Finder is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.4 seconds.