TDK-LAMBDA CA1500-XXXXXX
Specifications
Manufacturer
TDK-Lambda
Manufacturers Part #
CA1500-XXXXXX
Industry Aliases
CA1500-XXXXXX
Brand
TDK-Lambda
Series
Alpha
Factory Pack Quantity
1
Cooling Method
Air-Cooled
Efficiency
75%
IP Rating
IP10
Isolation
4300 VDC
Mechanical Style
Modular
Mounting
Chassis
Operating Temperature
0 to + 70°C
Package Type
Enclosed
Power
1500 W
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
+ Power INNOVATION • SOLUTIONS • SUPPORT • RELIABILITY • Up to 1500W output • Up to 16 outputs • Voltages up to 48V, Current up to 300 Amps • Fast-on output connection • Worldwide approvals & CB report • Medical Approval Option • 3 Year Warranty Key Market Segments & Applications Instrumentation Broadcast Alpha Medical ATE Automation Industrial Computing 400, 600, 1000 & 1500 Watts Modular Security Lifesciences/Laboratory Network Servers and Routers INPUT Alpha 400 90 - 264Vac Alpha 600 90 - 264Vac, 160 - 358Vdc Input Voltage Alpha 1000 85 - 264Vac, 120 - 360Vdc Alpha 1500 85 - 264Vac (1000W below 150Vac input) Input Frequency 47 - 63Hz (440Hz with reduced PFC - consult factory) Inrush Current <50A at 25°C and 264Vac (cold start) 250Vac HBC Fast Acting (not user accessible) 10A for 400W Input Fuse 12A for 600W 20A for 1000W and 1500W Leakage Current 1.1mA max at 264Vac & 63Hz Lower Leakage Option see configuring guide Power Factor 0.99 typical OUTPUT Voltage / Current See module output table Turn on Delay 1.5s max at 90Vac (150Vac for Alpha 1500W) & 100% rated output power Rise Time <50ms to 90% of voltage, monotonic rise above 10% Turn on Overshoot <5% or 250mV Load type dependant, no overshoot with resistive load Efficiency 75% typical at 230Vac & 100% rated power, config dependent at 90Vac & 100% rated output power Hold up 15ms min 13ms for 1000W, 8ms for 1500W and at 207Vac for 1500W Ripple & Noise <2% (or 100mV if greater) Pk- Pk, using EIAJ test method & 20MHz bandwidth Voltage Accuracy <1% of set Voltage Remote Sense Yes Standard on single output modules Minimum Load No on any output Temperature Coefficient <0.02% of rated voltage per °C Load Regulation <0.5% or 25mV for 0-100% load change (with sense connected, <2% without) Line Regulation <0.5% for 90 - 264Vac input change (210-264Vac for 1500W) Cross Regulation <0.2% for 100% load change on any other output <10% of set voltage for 50% load change (above 25% load) Transient Response Recovery 500µs for recovery to 1% or 100mV of set voltage (1000µs for S module) Over Voltage Protection Standard for all outputs Over Current Protection Standard for all outputs Short Circuit Protection <150% of rated current, when output voltage <1% Over Temperature Protection Yes Shuts down all outputs. Cycle ac off / on to reset Note shutdown temp varies according to ambient, output power and input V ALPHA SERIES 1 Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 SAFETY APPROVALS Date Amendments Date Amendments IEC 60601-1a EN 60950-1 2001 1988 A1, A2 UL 60601-1a UL 60950-1 2003 2003 CSA 60601-1a CSA22.2 No 60950-1 2003 2003 IEC60950-1* 2001 CE Mark LV Directive 2006/95/EC (EN60950-1) * CB Certificate and report available on request a - Only for LL, RL and TL leakage variants. CA400 + CA1000 only PRODUCT, GENERIC & COLLATERAL STANDARDS Compliant to High Low Voltage Power Supply, EMC EN61204-3: 2001 Class A emissions for CA1000 / CA1500 Severity Immunity Medical Electrical Equipment, EMC EN61601-1-2: 2001 Compliant Class A emissions for CA1000 / CA1500 Immunity for residential, commercial and EN61000-6-1: 2001 Compliant light industrial environments Immunity for industrial environments EN61000-6-2: 2001 Compliant Emissions for residential, commercial and EN61000-6-3: 2001 Compliant CA1000 and CA1500 not compliant light industrial environments Emissions for industrial environments EN61000-6-4: 2001 Compliant EMISSIONS Class B (as per CISPR.22) See application note for details. Radiated Electric Field EN55022 Class A for Alpha 1000/1500 Only for ‘S’ type leakage versions Class B (as per CISPR.22) Only for ‘S’ type leakage versions. Conducted Emissions EN55022 Class A for Alpha 1000/1500 ‘M’ & ‘L’ types meet Class A Conducted Harmonics EN61000-3-2: 2001 Compliant to Class A Compliant - d only. Flicker EN61000-3-3: 1995 + A1:2001 max IMMUNITY Criteria Air discharge 15kV Electrostatic Discharge EN61000-4-2 Level 4 A Contact discharge 8kV Electromagnetic Field EN61000-4-3 Level 3 10V/m (tested to 12V/m) A Input 4kV Fast / Burst Transient EN61000-4-4 Level 4 Outputs 2kV, A Tested at 5kHz and 100kHz Line to Line (Differential) 1.1kV Surge Immunity EN61000-4-5 Level 3 A Line to Earth (Common Mode) 2.2kV Conducted RF Immunity EN61000-4-6 Level 3 10V (tested to 12V) A Power Frequency Magnetic Field EN61000-4-8 Level 4 30A Continuous A Voltage Dips, Variation, A EN61000-4-11 Class 3 B for 5s interruptions Interruptions Voltage Fluctuations EN61000-4-14 Class 3 For 100 to 240V nominal A ENVIRONMENT Temperature 0°C to 70°C operational, -40° to 85°C storage (max 12 months) Derating 50°C to 70°C derate each output by 2.5% per °C Low Temperature Start-up -20°C Humidity 5-95% RH non condensing Shock 3000 shocks, each of 10g (16ms) half sine Vibration 10 - 200Hz @ 1.5g Altitude 3,000 metres operational (15,000 metres non operational) Pollution Degree 2, Material group 3 IP Rating IP 10 ISOLATION Input to Output Reinforced 4.3 kV (dc) Output to Earth Operational 500 V (dc) Input to Earth Basic 2.3 kV (dc) Output to Output Operational 500 V (dc) ALPHA SERIES 2 Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 OUTPUT VOLTAGES (single output modules) (twin output modules) Adjustment Amps Slots Module V1 Adjustment Amps V2 Adjustment Amps Slots Module A 4.5 - 5.5 60 2 E 5 - 16 8 5 - 16 8 1 AA 4.5 - 6.5 60 2 EB 4.5 - 5.5 9 4.5 - 5.5 9 1 B 4.5 - 5.5 25 1 EQ 4.5 - 5.5 9 2.7 - 3.9 9 1 BB 4.5 - 6.5 25 1 H 18 - 32 5 18 - 32 5 1 16 C 5 - 16 1 P 18 - 29 5 5 - 16 8 1 a D 18 - 29 8 1 F 9 - 16 33 2 25 G 17.5 - 29 2 b 10 J 30 - 48 2 c K 18 - 29 15 2 L 1.8 - 3.2 25 1 M 5 - 16 8 1 5 N 18 - 32 1 d Q 2.7 - 3.9 25 1 R 2.7 - 3.9 60 2 S 2.5 - 5.7 85 2 T 1.8 - 3.2 60 2 a) 12A max above 12V U 10 - 21 16 1 b) 21A max above 24.5V W 4.5 - 5.5 15 1 c) Derate output current by 0.25A / V above 40V Z 4.5 - 5.5 25 1 d) 1A max above 29V Alpha Configuring Guide The extensive range of output modules and options make it possible to achieve many combinations of Volts and Amps. To achieve the optimum configuration, please contact our sales office. However you can also create your own configuration from this datasheet by using the guide below. Configuring from Datasheet 1 Calculate total output power to determine Alpha 400W, 600W, 1000W or 1500W and select converter, then select required Cooling and Leakage Current from the following table:- CA 400 QF LL 400 (5 slots) 600 (5 slots) Output Power empty Standard 1.1 mA 1000 (7 slots) ML 500µA 1500 (8 slots) Earth Leakage Current LL 240µA empty Forward air - Standard (at 264Vac, 63Hz) RL 110µA a QF Cooling Forward air - Quiet fan TL 50µA RAb Reverse air Notes: a) CA400/600 only. CA400 derates to 300W, CA600 derates to 475W b) Contact sales office for details 2 Select Output Modules and Options from the Output Voltages tables. Example - if you require 5.2V / 18A with output inhibit : - a) select B as closest match for voltage and current and prefix with voltage (e.g. 5.2B) b) add suffix for option (if required) ‘_PA’ for parallel/current share (for N+1 redundant applications) ‘_PP’ for parallel (increase current from one PSU) ‘_IN’ for inhibit ‘_RP’ for remote programming ‘_MF’ (only applicable on 1st module) for global inhibit, ac fail and 5V/50mA standby supply c) repeat for other outputs Ensure that the total width of all selected modules is within the slots for the chosen converter. For example:- CA600LL 5A 12/12E 24D which represents a four output 600W Alpha with Forward air, 240µA Earth Leakage, with:- Output 1 = 5V / 60A with remote sense Output 2 = 12V / 8A Output 3 = 12V / 8A Output 4 = 24V / 8A with remote sense 3 Contact TDK-Lambda to validate configuration and issue a part number. ALPHA SERIES 3 Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 4 1 1 slot, 2 output 1 slot, 1 output 2 slot, 1 output Option Connections 5 2 IN, PA, 6 3 PP, RP + + + Option - - - Pin IN option PA option PP option RP option MF option 1 n/c + Sense + Sense + Sense Inhibit (low) + 6 + 5 - 2 Module Good Module Good n/c - Sense 5V supply 4 Remote sense 3 + - 2 3 Inhibit Star point n/c Control 2 Power Fail - 1 4 n/c - Sense - Sense n/c 0V 5 - Power - Power n/c Control 1 Inhibit (high) 6 - Power Star point n/c n/c n/c Alpha 400 Alpha 600 ALPHA SERIES 4 Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 MF option Alpha 1000 Alpha 1500 ALPHA SERIES 5 Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 TDK-LAMBDA EMEA AUSTRIA TDK-LAMBDA GERMANY GmbH Telephone: +43 (0) 2256 655 84 Aredstraße 22 Facsimile: +43 (0) 2256 645 12 A-2544 Leobersdorf Web: www.lambda-austria.com FRANCE TDK-LAMBDA FRANCE SAS Telephone: +33 (0) 1 60 12 71 65 ZAC des Delaches, BP1077 - Gometz le Chatel Facsimile: +33 (0) 1 60 12 71 66 91940 Les Ulis Web: www.lambda-f.com GERMANY TDK-LAMBDA GERMANY GmbH Telephone: +49 (0) 78 41 666 0 Karl-Bold-Straße 40 Facsimile: +49 (0) 78 41 5000 D-77855 Achern Web: www.lambda-germany.com ISRAEL NEMIC LAMBDA LTD Telephone: +972 (0) 3 902 4333 Kibbutz Givat Facsimile: +972 (0) 3 902 4777 Hashlosha 48800 Web: www.nemic.co.il ITALY TDK-LAMBDA ITALY s.r.l. Telephone: +39 (0) 02 61 29 38 63 Via dei Lavoratori 128/130, Facsimile: +39 (0) 02 61 29 09 00 20092, Cinisello Balsamo (Mi) Web: www.lambda-italy.com SWEDEN TDK-LAMBDA SCANDINAVIA Telephone: +46 (0) 8 598 94 090 PO Box 546, Rallervägen 41 Facsimile: +46 (0) 8 540 66 096 SE-184 25. Åkersberga Web: www.lambda-scandinavia.com UK TDK-LAMBDA UK Telephone: +44 (0) 1271 856666 Kingsley Avenue Facsimile: +44 (0) 1271 864894 Ilfracombe Devon EX34 8ES Web: www.lambda-gb.com TDK-LAMBDA NORTH AMERICA visit http://us.tdk-lambda.com/ for a list of TDK-Lambda offices and distributors TDK-LAMBDA ASIA visit http://www.tdk-lambda.com/ for a list of TDK-Lambda offices and distributors LOCAL DISTRIBUTION ALPHA SERIES 6 Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the CA1500-XXXXXX?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods