ARTESYN IHP12L3A(73-958-0001L)

Description
12000 W, Single Output, 12 VDC@44 A Industrial/Medical AC-DC Power Supply
Part Number
IHP12L3A(73-958-0001L)
Price
Request Quote
Manufacturer
ARTESYN
Lead Time
Request Quote
Category
Circuit Protection » AC-DC Power Supply
Specifications
Manufacturer
Artesyn
Manufacturers Part #
IHP12L3A(73-958-0001L)
Industry Aliases
IHP12L3A (73-958-0001L)
Brand
Artesyn Embedded Technologies
Series
iHP
Factory Pack Quantity
1
Compliance
Semi F47
Connection Type
Terminal
Cooling Method
Internal Fan
Dimensions
19.79 x 19.00 x 5.22"
Efficiency
91%
Industry
Industrial, Medical
Input Type
AC - 3 phase
Input Voltage Nominal
208/240 VAC
IP Rating
IP20
Isolation
5000 VAC
Mechanical Style
Modular
Mounting
Rack Mount
Operating Temperature
0 to + 70°C (see derating)
PFC
Yes
Power
12000 W
Subcategory
AC-DC Power Supply
Weight
21.6 kg
Datasheet
Extracted Text
POWER Modular High Power System Data Sheet Up to 24000 Watts Total Power: Up to 24 KW Input Voltage: 180-264 Vac 342-528 Vac Single Phase or 3-Phase # of Outputs: Up to 8 SPECIAL FEATURES iHP12 iHP24 Multi output intelligent and modular high power system Standard 19” rack Color: "i" 100% Blue, 50% Magenta, Font: Minion Bold for VS iHP24 Electrical Specifications 0% Yellow, 0% Black Minion italic for i ; size for each is the same "VS" - 100% Black Created on Mac Outputs parallel up to 1600 A Input Parameter 19” Rack 24 KW strapped as 19” Rack 24 KW strapped as Outputs series up to 1000 V 3-phase 380/480 Vac Nominal 3-phase 208/240 Vac Nominal 100% digital control (iHP24H3A/L) (iHP24L3A/L) Outputs program as voltage or current Input range 342 Vac to 528 Vac 187.5 Vac to 264 Vac source (Nominal rating 380/480 Vac) (Nominal rating 208/240 Vac) Versatile input configurable to: Number of phases 3-phase (Wye or Delta) 4 wire total (3-phase and 1 protective earth ground) • Low line 180-264 Vac single phase and 3-phase Frequency 47-63 Hz • High line 342-528 Vac 3-phase Phase detection Loss of phase will inhibit unit off. Medical safety approved – NO Housekeeping/comms must continue with phase loss. ISOLATION XFMR NEEDED Max current/phase 51 A @ 342 Vac 84 A @ 187.5 Vac Flexible control interfaces (Note 1) 40 A @ 432 Vac Air cooled Undervoltage Nominal input locked on at turn-on. Undervoltage shutdown at 15% below nominal. Semi F47 compliance detection Turn-on at 12% below nominal. Not to interfere with SEMI F47 specs. Field upgradeable firmware Current inrush 2.5 x Max input current Programmable slew rate Power factor > 0.98 @ full load and nominal line Fast current slew rate up to 200 Hz Harmonic distortion THD < 13%, PWHD < 22% (refer to EN 61000-3-12) Active power factor correction Line interruption Designed to meet SEMI F47-0706, 53, 58, S14 at nominal input voltages User defined command profiles Input leakage current < 2.5 mA (Note for fixed condition 3rd edition leakage = 5 mA) Power switch Front panel power switch provided SAFETY Input protection Internal fuse (not user serviceable) nd UL 60950-1 2 Edition; EN60950-1; Input overvoltage IEC60950-1/EN60950 Up to 115% of nominal input shall not damage unit protection nd CSA C22.2 No. 60950-1-07, 2 Edition Phase imbalance ≤ 5% EN60601-1; IEC60601-1; IEC60601 Rack parallel Up to 6 racks (144 KW) UL 60601-1 1st Edition; ANSI/AAMI rd Efficiency > 90% @ 3P 380 Vac full load > 91% @ 3P 240 Vac full load ES60601-1 (2005 + C1:09 + A2:10) 3 > 91% @ 3P 480 Vac full load > 90% @ 3P 208 Vac 3P full load Ed Standby voltage 5 V CAN/CSA-C22.2 No. 60601-1 (2008) Standby regulation 4.75 - 5.25 V CB Certificate and Report Standby max current 1 A CE (LVD+RoHS), EN60950-1 Note 1: Analog 0-5 V or 0-10 V separate for voltage or current; Digital Ethernet UDP, RS485, CAN or Ethernet TC/IP with PowerPro Connect Module option. Command protocol is patterned to PMBus specification using a proprietary transaction protocol. iHP Data Sheet iHP12 Electrical Specifications Input Parameter 19” Rack 12 KW strapped as Type: 19” Rack 12 KW strapped as Type: 19” Rack 12 KW strapped 1-phase 200/220/230/240 Vac 3-phase 200/208/240 Vac Nominal as 3-phase 380/480 Vac Nominal Nominal (iHP12L1A) (iHP12L3A) (iHP12H3A) Input range 180 Vac to 264 Vac 180 Vac to 264 Vac 342 Vac to 528 Vac (Nominal rating 200/220/230/240 Vac) (Nominal rating 200/208/240 Vac) (Nominal rating 380/480 Vac) 1-phase 3-wire total (2-phase and 1 Number of phases 3-phase (Wye or Delta) 4-wire total (3-phase and 1 protective earth ground) protective earth ground) Frequency 47-63 Hz Loss of phase will inhibit unit off. Phase detection NA Housekeeping/comms must continue with phase loss. 23 A @ 342 Vac Max current/phase 75 A @ 180 Vac 44 A @ 180 Vac 19 A @ 432 Vac Nominal input locked on at turn-on. Undervoltage shutdown at 15% below nominal. Turn-on at 12% below nominal. Undervoltage detection Not to interfere with SEMI F47 specs. Current inrush 2.5 x Max input current Power factor > 0.99 @ full load and nominal line > 0.98 @ full load and nominal line Harmonic distortion THD < 13%, PWHD < 22% (refer to EN 61000-3-12) Line interruption Designed to meet SEMI F47-0706, 53, 58, S14 at nominal input voltages Input leakage current < 1.25 mA <2.5 mA Power switch Front panel power switch provided Input protection Internal fuse (not user serviceable) Input overvoltage protection Up to 115% of nominal input shall not damage unit Phase imbalance NA < 5% < 5% Rack parallel Up to 6 racks (72 KW) > 91% @ 1P 240 Vac full load > 91% @ 3P 240 Vac full load > 90% @ 3P 380 Vac full load Efficiency > 90% @ 1P 208 Vac/200 Vac full load > 90% @ 3P 208 Vac/200 Vac full load > 91% @ 3P 480 Vac full load Standby voltage 5 V Standby regulation 4.75 - 5.25 V Standby max current 1 A EMC/Immunity Parameter All Models (Unless otherwise specified) ESD EN61000-4-2 (IEC1000-4-2) Fast Transients EN61000-4-4 (IEC1000-4-4) Surge Immunity EN61000-4-5 (IEC1000-4-5) Conducted Immunity EN61000-4-6 (IEC1000-4-6) Radiated Immunity EN61000-4-3 (IEC1000-4-3) Power Frequency Magnetic Field EN61000-4-8 Voltage Dips, Short Interruptions and Voltage Variations EN 61000-4-34 Conducted Emission EN55011, FCC CFR 47, Part 15, Subpart B Radiated Emission EN55011, FCC CFR 47, Part 15, Subpart B iHP Data Sheet Electromagnetic Compatibility/Input Transient PSU Performance Category Standard Frequency Level/Limits 1 Criteria 3 Radiated Emissions EN 55011/CISPR11 30 M - 1 GHz Class A 5 dB Margin FCC CFR 47, Part 15, 30 M - 1 GHz Class A 5 dB Margin Subpart B >1 GHz (see standard) 3 Conducted Emissions EN 55011/CISPR11 150 k - 30 MHz Class A 5 dB Margin 2 Power Line Harmonics EN 61000-3-12 See standard See standard 2 Voltage Fluctuations EN 61000-3-11 See standard See standard Radiated Immunity EN 61000-4-3 80 M - 2 GHz 10 V/meter A ESD EN 61000-4-2 8 KV contact, 15 KV Air A Electrical Fast Transient EN 61000-4-4 +/- 4 KV A Surge AC EN 61000-4-5 2 KV DM, 2 KV CM A IEEE C62.41 2 KV DM, 2 KV CM A 6 KV, CM & DM Fail Safe Conducted Susceptibility EN 61000-4-6 150 KHz – 80 MHz 10 Vrms A 2 Voltage Dips and Sags EN 61000-4-34 >95% reduction for 10 mS A SEMI F47 >30% reduction for 500 mS A >95% reduction for 500 mS C 20% reduction for 5000 mS A 30% reduction for 500 mS A 50% reduction for 200 mS A 60% reduction for 200 mS B Notes: 1 Performance Criteria as defined by EN 300 386 V1.3.3 2 Applies to AC power supplies only. 3 Conducted and radiated emissions are measured using a typical set-up. In an actual end system, additional EMI filters may be required. OUTPUT – General Specs Parameter MODULE CODE SL SQ SW S8 S1 S2 # Outputs 1 1 1 1 1 1 Nominal O/P (V) 12.0 V 24.0 V 48.0 V 80.0 V 125.0 V 250.0 V Max Power (W) 2400 W 2880 W 3000 W 3000 W 3000 W 3000 W O/P Current Range (A) 0.0 A - 200 A 0.0 A - 120 A 0.0 A - 62.5 A 0.0 A - 37.5 A 0.0 A -24 A 0.0 A -12 A Power Density (W/cu-in) 32.5 39.0 40.6 40.6 40.6 40.6 Efficiency (%) 93.5 93.5 93.5 93.5 93.5 93.5 Module Input Voltage 400 V Module Operating Temp -0 °C to +65 °C; Baseplate Temp TBD Series Operation 250 V modules can be connected in series up to 800 V for Medical and 1000 V for ITE Parallel Operation Up to 8 modules can be paralleled in 1 rack, with up to 6 racks connected in parallel. Single Wire Parallel connection will be provided as part of configuration iHP Data Sheet OUTPUT – Module in Voltage Source Mode Voltage Source MODULE CODE SL SQ SW S8 S1 S2 Nominal Output (V) 12 24 48 80 125 250 Setting Range (V) 0.6 V - 14.4 V 1.2 V - 28.8 V 2.4 V - 57.6 V 4.0 V - 96.0 V 6.25 V - 150.0 V 12.5 V - 300.0 V Low Frequency RMS Ripple (mV) 24 48 96 160 250 500 Line Regulation (mV) 12 24 48 80 125 250 Load Regulation (mV) 24 48 96 160 250 500 P-P Ripple (mV) 60 120 240 400 625 1250 Drift (Temp Stability) ±0.05% of Iout Rated over 8 hours, after 30 minute warm up, constant Line, Load and Temp (PPM/°C) Temp Coefficient 200 Pgm Accuracy (mV) Digital: 0.1% of Nominal Output Voltage; Analog: 1.0% of Nominal Output Voltage Pgm Resolution (mV) SL=TBD; SQ=1; SW=2; S8=8; S1=6; S2=21 Meas Accuracy (mV) 0.2% + 0.2% of Nominal Output Voltage Meas Resolution SL=TBD; SQ=1; SW=2; S8=8; S1=6; S2=21 Transient Response Max 5.0% deviation from current set point must recover within 1mS for a 50% step load. Current Sense Method Internal Shunt; External Shunt can be used for better temperature stability. OUTPUT – Module in Current Source Mode Current Source - Programmable load compensation available for resistive and inductive loads; capacitive load applications; and LED drive applications MODULE CODE SL SQ SW S8 S1 S2 Nominal Output (V) 12 24 48 80 125 250 Setting Range (A) 0.0 A - 200 A 0.0 A - 120 A 0.0 A - 62.5 A 0.0 A - 37.5 A 0.0 A - 24 A 0.0 A - 12 A RMS Ripple (mA) 200 120 62.5 37.5 24 12 Line Regulation (mA) 200 120 125 93.75 48 24 Load Regulation (mA) 800 480 250 150 96 48 P-P Ripple (mA) N/A Drift (Temp Stability) ±0.05% of I Rated over 8 hours, after 30 minute warm up, constant Line, Load and Temp out Temp Co-efficient SL, SQ = 300 PPM; All other modules are 200 PPM. (PPM/°C) Temp Co-efficient at rack level is [Temp Co-efficient (module level)] + [4500 PPM of Iout-max] Pgm Accuracy (A) 0.7% digital, 1.3% analog of rated output max Pgm Resolution (mA) 79.2 26.4 13.2 10 5.2 2.6 Meas Accuracy 0.7% + 0.7% of Rated Output Max Meas Resolution 79.2 26.4 13.2 10 5.2 2.6 Transient Response 0-63% output current change in 7.5 mSec, residual value 1%, settling time 35 mSec Current Sense Method Internal Shunt / External Shunt iiHP Data Sheet HP Data Sheet Environmental Specifications Operating Conditions ALL MODELS (Unless Otherwise Specified) Operating Temperature 0 °C to +50 °C at 100% rated load. Storage Temperature -40 °C to +85 °C. For Liquid Cooled models, liquid must be drained before storage Operating Humidity 20% - 90% non condensing Storage Humidity 10% - 95% non condensing Operating Altitude Up to 9,842 feet above sea level (3,000 meters) Storage Altitude Up to 30,000 feet above sea level (9,144 meters) Vibration Operating Sinusoidal Vibration MIL-STD-810G Method 528 Procedure I (Type 1): NEBS Office Vibration Environment, Alternate Procedure Operating Random Vibration: IPC-9592B Class 1 Non-Operating Vibration (Packaged): IPC-9592B Class 1; MIL-STD-810G, Method 514.6, Procedure 1, Category 7, Table 514.6C-VII General Exposure Shock MIL-STD-810G Method 516.6 Procedures I, II, IV, VI Shipping and Handling NSTA for <100 lbs; MIL-STD-2073-1 >100 lbs <65 dBA with 80% load @ 30 °C at nominal input voltage with Smart Fan algorithm to be optimized based on module Cooling and Audible Noise and rack thermal sensors. When modules are inhibited via software control, the fan speed is reduced to idle and acoustic noise is <46 dBA. With modules off via front panel switch fans are at idle for 1 min, and off for 9 min. Ingress Protection Fan Cooled = IP20 Pollution Degree 2 RoHS Compliance Yes Standard Markings SW Module and Marking Detail Module Code Label iHP Data Sheet Ordering Information MODULE CODES CASE CODE PARALLEL/SERIES CASE CODE MOD CODE (up to 8 modules) iHP**XYA- XV- -XX -XXX Case Module Case Code Decoder Case Code Decoder iHP**XYA XV Decoder Decoder First Digit Second Digit ** = Case Power X = Output Type 0 = None 0 = None 12 = 12 KW 19” Rack S = Single 1 = Slot 1&2 P = Parallel 24 = 24 KW 19” Rack X = Voltage Range V = Nominal Voltage 2 = Slot 2&3 S = Series L = Low Range*180-264 L = 12 V 3 = Slot 3&4 1 = Combo 2 P/S H = High Range 342-528 Q = 24 V 4 = Slot 4&5 2 = Combo 2 S/P Y = Input Phase W = 48 V 5 = Slot 5&6 3 = Combo 3 P/P/S 1 = Single Phase 8 = 80 V 6 = Slot 6&7 4 = Combo 3 P/S/P 3 = 3-Phase Z = Cooling 1 =125 V 7 = Slot 7&8 5 = Combo 3 P/S/S A = Air Cooled 2 = 250 V 8 = Slot 1,2&3 6 = Combo 3 S/P/P 9 = Slot 1,2,3&4 7 = Combo 3 S/P/S *Lowest possible input for the 24 kW version is 187.5 Vac A = Slot 1,2,3,4&5 8 = Combo 3 S/S/P B = Slot 1,2,3,4,5&6 9 = Combo 4 P/P/P/S MODEL NUMBER SHORTCUT C = Slot 1,2,3,4,5,6&7 A = Combo 4 P/P/S/P D = Slot 1,2,3,4,5,6,7&8 B = Combo 4 P/P/S/S For repeated like modules in parallel or series, instead of listing all the same modules separated by a “-”, you can simply list the E = Slot 1&2; 3&4 C = Combo 4 P/S/P/P module once and then follow by the number of times it repeats F = Slot 1&2; 3&4; 5&6 D = Combo 4 P/S/P/S enclosed in parenthesis. G = Slot 1&2; 3&4; 5&6; 7&8 E = Combo 4 P/S/S/P For example: H = Slot 1,2&3; 4&5 F = Combo 4 P/S/S/S iHP24H3A-SW-SW-SW-SW-SW-SW-S8-S8-00 J = Slot 1,2&3; 4&5; 6&7 G = Combo 4 S/P/P/P would become: K = Slot 1,2&3; 4,5&6 H = Combo 4 S/P/P/S iHP24H3A-SW(6)-S8(2)-00 L = Slot 1,2&3; 4,5&6; 7&8 J = Combo 4 S/P/S/P M = Slot 1,2,3&4; 5&6 K = Combo 4 S/P/S/S N = Slot 1,2,3&4; 5&6; 7&8 L = Combo 4 S/S/P/P P = Slot 1,2,3&4; 5,6&7 M = Combo 4 S/S/P/S R = Slot 1,2,3&4; 5,6,7&8 N = Combo 4 S/S/S/P S = Slot 1,2,3,4&5; 6&7 T = Slot 1,2,3,4&5; 6,7&8 U = Slot 1,2,3,4,5&6; 7&8 iHP Data Sheet Case Specs - Outline Detail Front Panel Standard Markings Input and Comms Standard Markings (Standard for both 12 KW and 24 KW) (View of 24KW shown. Comms interface is horizontal on the 12KW). See mechanical drawings. Module Specs - Outline Detail Module J1 Signals Pin # Function Function Pin # 5 Dummy Net SYS_M_FAULT# 10 4 0-5VEXT_IPROG SYS_M_ENABLE# 9 3 0-10VEXT_IPROG SYS_RTN 8 2 0-5VEXT_VPROG SYS_M_INHIBIT 7 1 0-10VEXT_VPROG Dummy Net 6 Module J2 Signals Pin # Function Function Pin # 6 Dummy Net Dummy Net 12 5 IMON VMON 11 4 D_RTN ISHARE 10 3 EXT_ISENSE+ EXT_ISENSE- 9 2 D_RTN V_SNS- 8 1 V_SNS+ D_RTN 7 J1 mating housing Molex Micro-fit MPN: 43025-1000 J2 mating housing Molex Micro-fit MPN: 43025-1200 Crimp Terminal AWG 20-24 Crimp Terminal Molex MPN: 43030-0002 iiHP Data Sheet HP Data Sheet iHP24 Series - Mechanical Drawings INPUT CONNECTOR NOTE: TERMINAL BLOCK 1. WEIGHT: DETAIL VIEW ROTATED 90 RACK STANDALONE, 35.4 Kg SCALE 1:2 RACK WITH 8 MODULES, 52.9 Kg 2. REFER TO PRODUCT LABELS FOR SAFETY MFR: PHOENIX CONTACT INFORMATION AND SPECIAL INSTRUCTIONS. MPN: UWV 25 3. REFER TO PRODUCT SPECIFICATION FOR CONDUCTOR RANGE OPERATIONAL ENVIRONMENT. 10 - 2 AWG 4. DO NOT OBSTRUCT INLET AND OUTLETS. TIGHTENING TORQUE (28) 4.5 N-m MAX +0.10 (3) 2 -0.25 INPUT (752.28) CONNECTOR AC-INPUT RATING LABEL EARTH GROUND STUD M6 TIGHTEN TO 6.5 N-m MAX. AIRFLOW DIRECTION (43) +0.10 MODULE 706.8 0.8 2 -0.25 COMMS AREA CONNECTORS 514.34 415.92 317.49 219.07 (45.48) 120.64 USB PORT STANDARD ETHERNET 8PIN RJ45 RS485/CAN 6PIN RJ11 TTL DSUB 9 (18.4) SIDE PANEL MOUNTING (BOTH SIDE) MAIN LABEL METRIC M5, 6mm MAX SCREW PENETRATION TOTAL 10 LOCATIONS COMMS CONNECTORS 4.5 N-m MAX TIGHTENING TORQUE DETAIL VIEW ROTATED 90 482.6 0.8 SCALE 1:2 460 (13.4) (15.3) 21 21 (28) (50.5) 132.5 0.5 447 0.8 (68) 132.5 0.5 37.7 57.15 6.8 4X 66.25 5X iiHP Data Sheet HP Data Sheet iHP12 Series - Mechanical Drawings INPUT CONNECTOR NOTE: TERMINAL BLOCK 1. RACK WITH 4 MODULES, 30.3 Kg. DETAIL VIEW TOTATED 90 2. REFER TO PRODUCT LABELS FOR SAFETY SCALE: NTS INFORMATION AND SPECIAL INSTRUCTIONS. 3. REFER TO PRODUCT SPECIFICATION FOR MFR: PHOENIX CONTACT OPERATIONAL ENVIRONMENT. MPN: UWV 25 4. DO NOT OBSTRUCT INLET AND OUTLETS. CONDUCTOR RANGE: 10 - 2 AWG (28) TOGHTENING TORQUE: 4.5 N-m MAX +0.10 (3) 2.05 -0.25 (502.68) INPUT CONNECTOR AC-INPUT RATING LABEL EARTH GROUND STUD M6 TIGHTEN TO 6.5 N-m MAX COMMS CONNECTORS AIRFLOW DIRECTION A (43) 456.2 MODULE 415.92 AREA 317.49 216.07 (45.48) 120.64 USB PORT STANDARD USB PORT ETHERNET 8PIN RJ45 ETHERNET RS485/SCAN 6PIN RJ11 SIDE PANEL MOUNTING (BOTH SIDE) (18.4) MAIN LABEL METRIC M5. 6mm MAX SCREW PENETRATION RS485/SCAN TOTAL 8 LOCATIONS. 4.5 N-m MAX TIGHTENING TORQUE TTL DSUB 9 482.6 0.8 460 TTL COMMS CONNECTORS DETAIL VIEW 13.4 15.8 wdsds (50.5) 132.5 0.6 447 0.8 (68) 37.7 57.15 (4X)6.8 66.25(4X) (2X) 8.5 iiHP Data Sheet HP Data Sheet iHP Modules - Mechanical Drawings (2X)33.8 255.1 (7.5) MOLEX 43045-1001 MOLEX 43045-1201 256.3 (2X)49.8 (2X)M3 (4X)M4 PowerPro Connect Module Part number:73-778-000 The PowerPro Connect Module (purchased separately) can provide standard Ethernet interface via the internet to a cloud- and dashboard-based user-configurable GUI. WORLDWIDE OFFICES Americas Europe (UK) Asia (HK) 2900 S.Diablo Way Waterfront Business Park 14/F, Lu Plaza Tempe, AZ 85282 Merry Hill, Dudley 2 Wing Yip Street USA West Midlands, DY5 1LX Kwun Tong, Kowloon +1 888 412 7832 United Kingdom Hong Kong www.artesyn.com +44 (0) 1384 842 211 +852 2176 3333 Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and For more information: www.artesyn.com/power service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names, For support: productsupport.ep@artesyn.com trademarks, or registered trademarks of their respective owners. Specifications are subject to change without notice. © 2018 Artesyn Embedded Technologies, Inc. All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal. iHP DS 22Jan2018 114 0.5 44 0.5 (4.5) 17.6 16.9 24
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the IHP12L3A(73-958-0001L)?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods