ARTESYN NFS110-7902PJ
Specifications
Manufacturer
Artesyn
Manufacturers Part #
NFS110-7902PJ
Selling Alternatives
NFS110-7902P
Brand
Artesyn Embedded Technologies
Series
NFS110 M
Factory Pack Quantity
1
Cooling Method
Air-Cooled, Convection
Dimensions
7.00 x 4.25 x 1.80"
Efficiency
70%
Isolation
4000 VAC
Mechanical Style
Open / Enclosed Frame
Mounting
Chassis
Number of Outputs
4
Operating Temperature
0 to + 70°C
Output Amps 1
8 A
Output Amps 2
3.5 A
Output Amps 3
4.5 A
Output Amps 4
0.5 A
Output Voltage V1 Nominal
5.1 VDC
Output Voltage V2 Nominal
24 VDC
Output Voltage V3 Nominal
12 VDC
Output Voltage V4 Nominal
- 12 VDC
Power
110 W
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
POWER NFS110 Medical Series Data Sheet Single and quad output Total Power: 80 - 110 W Input Voltage: 100 - 240Vac 127 - 357 Vdc # of Outputs: Single, quad Special FeatureS 7.0 x 4.25 x 1.8 inch package Medical, dental and laboratory applica- tions Overvoltage and short circuit protection 110 W with 20 CFM UL, cUL and VDE approvals EN60601-1 and UL2601 medical approvals Available RoHS compliant Electrical Specifications 2 years warranty Output Voltage adjustability: +5.1 V o/p on multi’s ± 3.0% SaFety 5.1 V single output ± 3.0% EN60950-1/IEC60950-1 12 V single output 12 - 14 V EN60601-1 15 V single output 15 - 18 V 24 V single output 24 - 30 V UL60601-1/CSA C22.2 No. 601-1 File No. E182560 Line regulation: LL to HL, FL ± 0.1% max. All outputs on all units Overshoot/undershoot: At turn-on no lead 0% Temperature coefficient: All outputs ±0.02% / °C Overvoltage protection: Multi o/p 5.1 V only 6.25 V ± 0.75 V 5.1 V single 6.25 V ± 0.75 V 12 V single 15.75 V ± 1.0 V 15 V single 22 V ± 1.5 V 24 V single 33 V ± 2.5 V Output power limit: Primary power Pin max. 160 W limited Pout min. 110 W Short circuit protection: Burst mode operation Input Input voltage range: 100 - 240 Vac 127 - 357 Vdc Input frequency range: 47 - 440 Hz Input surge current: 110 Vac. 50 Hz 17 A 230 Vac. 50 Hz 25 A Safety ground leakage 132 Vac 50 μA current: 264 Vac 100 μA All specifications are typical at nominal input, full load at 25 °C unless otherwise stated NFS110 Medical Series Data Sheet EMC Charateristics Conducted emissions: EN55022, FCC part 15 Level A Radiated emissions: EN55022, FCC part 15 Level A ESD air: EN61000-4-2, level 3 Perf. criteria 1 ESD contact: EN61000-4-2, level 4 Perf. criteria 1 Surge: EN61000-4-3, level 3 Perf. criteria 1 Fast transients: EN61000-4-4, level 3 Perf. criteria 1 Radiated immunity: EN61000-4-5, level 3 Perf. criteria 2 Conducted immunity: EN61000-4-6, level 3 Perf. criteria 2 General Specifications Hold-up time: 110 Vac @ 80 W 35 ms 110 Vac @ 110 W 17 ms 230 Vac @ 80 W 140 ms 230 Vac @ 110 W 100 ms Efficiency: Multiple outputs 70% typical +5.1 V single 70% typical 12 V and 15 V singles 72% typical 24 V single 75% typical Isolation voltage: Input/output 4000 Vac Input/chassis 1500 Vac Approvals and standards: VDE0750, IEC60601, IEC1010, UL60601, CSA (see note 12) C22.2 No. 125 Singles 550 g (19.4 oz) Weight: Multiple outputs 600 g (21.2 oz) MTBF (@25 ºC) MIL-HDBK-217E 125,000 hours min. Environmental Specifications Thermal performance: Operating, see curve 0°C to +70°C (See notes 9, 10) Non-operating -40°C to +85°C 0 °C to 50 °C amb. convection cooled 80 W +50 °C to +70 °C, amb. convection cooled Derate 2 W/°C 0 °C to +50 °C, 20 CFM forced air 110 W +50 °C to +70 °C, 20CFM forced air Derate 2.75 W/°C Relative humidity: Peak, 0 °C to +50 °C, max. 60 seconds 110W Altitude: Non-condensing 5% to 95% RH Operating 10,000 feet max. Non-operating 40,000 feet max. Vibration (See Note 11): 5-500 Hz 2.4 G rms peak NFS110 Medical Series Data Sheet Ordering Information Output Currents Output Total (4) (13, 14, F) Ripple Model Numbers (5) (1) (2) (3) Voltage Regulation Max Peak Fan +5.1 V 8 A 20 A 10 A 50 mV ± 2.0% NFS110-7901PJ +12 V 4.5 A 9 A 5 A 120 mV ± 3.0% –12 V 0.5 A 1.5 A 1 A 120 mV ± 3.0% –5 V 0.5 A 1.5 A 1 A 50 mV ± 3.0% +5.1 V (I ) 8 A 20 A 10 A 50 mV + 2.0% NFS110-7902PJ A (6) +24 V (I ) 3.5 A 4.5 A 4.5 A 240 mV + 10 / – 5.0% B +12 V 4.5 A 9 A 5 A 120 mV ± 3.0% –12 V 0.5 A 1.5 A 1 A 120 mV ± 3.0% (7,8) 12 V 7 A 9 A 9 A 120 mV ± 2.0% NFS110-7912J (7,8) 15 V 5 A 7.3 A 7.3 A 150 mV ± 2.0% NFS110-7915J (7,8) 24 V 3.5 A 4.5 A 4.5 A 240 mV ± 2.0% NFS110-7924J Notes Transient Response 1. Convection cooled, 80 W maximum. NFS110-7901PJ +5.1 V (7.5-10 A) 150 mV peak, 1 ms recovery 2. Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total peak power must not exceed 110 W. +12 V (2.5-5 A) 100 mV peak, 0.5 ms recovery 3. Forced air, 20 CFM at 1 atmosphere, 110 W maximum. -12 V (0.5-1 A) 100 mV peak, 0.5 ms recovery 4. Figure is peak-to-peak. Output ripple is measured across a 50 MHz -5 V (0.5-1 A) 100 mV peak, 0.5 ms recovery bandwidth using a 12 inch twisted pair terminated with a 47 μF NFS110-7902PJ +5.1 V (7.5-10 A) 150 mV peak, 1 ms recovery capacitor. 5. Total regulation is defined at the static output regulation at 25 °C, +12 V (2.5-5 A) 100 mV peak, 0.5 ms recovery including initial tolerance, line voltage within stated limits and output -12 V (0.5-1 A) 100 mV peak, 0.5 ms recovery voltages adjusted to their factory settings. Also for NFS110-7902PJ, for 24 V (1.5-3 A) 300 mV peak,1 ms recovery 24 V output stated regulation I / I ² 5. This output will maintain ±5.0% A B NFS110-7905J +5.1 V (10-20 A) 250 mV peak, 1 ms recovery regulation if I ² 5 A, where I = +5.1 V output current and I = +24 V A A B output current. NFS110-7912J +12 V (4.5-9 A) 360 mV peak, 1 ms recovery 6. Single output models have floating outputs which may be referenced as NFS110-7915J +15 V (3.65-7.3 A) 450 mV peak, 1 ms recovery either positive or negative. Higher voltage supplies, may be adjusted NFS110-7924J +24 V (2.25-4.5 A) 720 mV peak, 1 ms recovery over a wide output voltage range, as long as the total output power does not exceed 80 Watts (natural convection) or 110 Watts (forced air). 7. Power fail detect not available on single output models. 8. Derating curve is application specific for ambient temperatures > 50 °C, for optimum reliability no part of the heatsink should exceed 90 °C and no semiconductor case temperature should exceed 100 °C. 9. Caution: Allow a minimum of 1 second after disconnecting the power when making thermal measurements. 10. The user should read the PSU installation instructions in conjunction with the relevant national safety regulations in order to ensure compliance. 11. Three orthogonal axes, random vibration, 10 minute test for each axis. 12. This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 13. The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 14. NOTICE: Some models do not support all options. Please contact your local Artesyn Embedded Technologies representative or use the on-line model number search tool at www.artesyn.com/power to find a suitable alternative. NFS110 Medical Series Data Sheet OPTIONAL POWER FAIL DETECT TIMING DIAGRAM AC (J1) mating connector Power fail detect signal (Note 8) Molex 09-50-3051 or Molex 09-91-0500 mating connector 50 ms ≤ T1 ≤ 200 ms AC INPUT with 2478 or equivalent crimp terminals. 4.75V 4.75V T2 will vary with line and load 5V OUTPUT T3 ≥ 3 ms HIGH 3.5V MIN LOW DC (J2) mating connector PFD SIGNAL Pout: 110 W 0-0.4 MAX T3 Molex 09-50-3131 or Molex 09-91-1300 mating connector PFD output is an open collector which will T1 T2 with 2478 or equivalent crimp terminals. sink ≤ 40 mA in the low state. 0.475 0.010 (12.07) 1.80 (45.72) MAX 1.00 0.005 (25.4) DERATING CURVE (See Notes 9, 10) 6-32 UNC 0.050 0.020 Output Power (Watts) 1.55 0.005 (4PL) 3.35 0.015 (85.09) (1.27) (39.37) 110W PIN 1 20 CFM FORCED AIR COOLING Voltage Adjust 80W Optional Power Fail J2 Detect Circuit 4.250 0.020 (Key = Pin 2) NATURAL 55W (107.95) CONVECTION COOLING T1 40W T1 3.750 Pin 1 0.005 (95.25) PIN 1 L1 11W 0.156 11W MINIMUM LOAD REQUIRED AT 230VAC J1 0W DIA. HOLE C6 0C 10C 20C 30C 40C 50C 60C 70C (4PL) F1 5A, 250 VAC 0.250 6.50 0.005 (165.1) 0.010 (6.35) 7.00 0.020 (177.8) 0.250 0.010 J1 ALL DIMENSIONS IN INCHES (mm) (6.35) Mechanical Notes A Metallic or non-metallic stand-offs (maximum diameter 5.4 mm) can be used in all four mounting holes without effecting safety approval. B The ground pad of the mounting hole near J1, allows system grounding through a metal stand-off to the system chassis. C The heat sink is grounded, and allows system grounding by mechanical connection to the system chassis. D The supply must be mechanically supported using the PCB mounting holes and may be additionally supported by the heatsink mounting holes. E It is always advisable to attach the power supply heat sink to another thermal dissipator (such as a chassis or finned heatsink etc). The resulting decrease in heat sink mounted component temperatures will improve power supply lifetime. F A standard L-bracket and cover is available for mounting which contains all screws, connectors and necessary mounting hardware. The kit is available, order part number “NFS110CJ”. NFS110 Medical Series Data Sheet Pin Connections J1 -7901PJ -7902PJ SINGLES Pin 1 AC Ground AC Ground AC Ground Pin 2 AC Neutral AC Neutral AC Neutral Pin 3 AC Line AC Line AC Line J2 Pin 1 +5.1 V +5.1 V V out Pin 2 +5.1 V +5.1 V V out Pin 3 +5.1 V +5.1 V V out Pin 4 Return Return Return Pin 5 Return Return Return Pin 6 Return Return Return Pin 7 Return Return Return Pin 8 +12 V +12 V V out Pin 9 +12 V +12 V V out Pin 10 PFD PFD N/C Pin 11 -12 V -12 V N/C Pin 12 Removed for Key Pin 13 -5 V +24 V N/C N/C = no connection. WORLDWIDE OFFICES americas europe (uK) asia (HK) 14/F, Lu Plaza 2900 S.Diablo Way Waterfront Business Park Tempe, AZ 85282 Merry Hill, Dudley 2 Wing Yip Street Kwun Tong, Kowloon USA West Midlands, DY5 1LX +1 888 412 7832 United Kingdom Hong Kong www.artesyn.com +44 (0) 1384 842 211 +852 2176 3333 While every precaution has been taken to ensure accuracy and completeness in this literature, Artesyn For more information: www.artesyn.com/power Embedded Technologies assumes no responsibility, and disclaims all liability for damages resulting from use of For support: productsupport.ep@artesyn.com this information or for any errors or omissions. Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. NFS110 Medical Series-DS 12.19.14 © 2014 Artesyn Embedded Technologies, Inc.
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the NFS110-7902PJ?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods